KEYPADS. M.series 20 B1 M.series Axess 21 B2 S.series 22 B3 S.series Lite 23 B4 A.series 24 B5 ECO.series 25 B6 W.series 26 B7 KB.

Size: px
Start display at page:

Download "KEYPADS. M.series 20 B1 M.series Axess 21 B2 S.series 22 B3 S.series Lite 23 B4 A.series 24 B5 ECO.series 25 B6 W.series 26 B7 KB."

Transcription

1 KEYPADS M.series 20 B1 M.series Axess 21 B2 S.series 22 B3 S.series Lite 23 B4 A.series 24 B5 ECO.series 25 B6 W.series 26 B7 KB.series 27 B8

2 M.series Thanks to a 30 year experience in the conception and manufacturing of keypad devices, EOZ has developed the M.series keypad range, designed to operate in varied environments and which can be used in different applications. Electrical life 1 million actuations for dome version Electrical life 4 million actuations for membrane version Choice available for key shape and dimension Anti-twist keys and anti pull off keys Laser engraving for a high flexibility B1 Standard colours of keys (other colours available): - Key top: natural (grey), green, red, yellow - Illumination: yellow and blue (standard) 5 VDC, 240mA Illuminated versions: blue, red, green, yellow and white. Dome version: < 1 Ohm Membrane version: < 200 Ohms 15kV with a metallic front plate -40 C to +85 C (-30 C for illuminated) -25 C to +85 C IP 67 (front face) IK 09 for standard versions with a 3mm 4.5N +/- 30% 1.9N +/- 30% 0.5 ±0.3 mm 1±0.3 mm 1 million actuations 4 million actuations thick front plate Dome version: Membrane version: (@+40 C) 56 days - UV resistance 4 Key version with marking Interface Non illuminated membrane Common point Non illuminated domes Common point Yellow Illuminated membrane Common point Yellow Illuminated domes Common point 12 Key version with Telephone marking Non illuminated membrane Non illuminated domes Yellow illuminated membrane Yellow illuminated domes Blue illuminated membrane Blue illuminated domes 16 Key version with Hexadecimal marking Non illuminated membrane Non illuminated domes Yellow illuminated membrane Yellow illuminated domes Blue illuminated membrane Blue illuminated domes 16 Key version with marking Banking Non illuminated membrane Non illuminated domes M04PARSANLPA M04PARSANSPA M04IARSAYLPA M04IARSAYSPA M12PARSANLMT M12PARSANSMT M12IARSAYLMT M12IARSAYSMT M12IARSABLMT M12IARSABSMT M16PARSANLMH M16PARSANSMH M16IARSAYLMH M16IARSAYSMH M16IARSABLMH M16IARSABSMH M16PARSANLMB M16PARSANSMB Mounting element Bracket FIX.M001 MOUNTING The keypads can be mounted from the rear, with different options possible: Brackets: 2 mounting clips made of ABS polycarbonate 4 holes in the back of the housing of the keypad for customised integration Tightening torque: 50 Ncm ±5 Ncm (screws for thermoplastic) TYPE OF STANDARD KEYS Standard colors: Natural aluminium, red, yellow and green Specific colors on request: blue, orange, anthracite grey.

3 M.series Axess A low-profile version of the M.series rugged keypad has been added to the range of products offered by EOZ your solutions partner. Just 8mm deep, the M.series Axess offers the same design flexibility and versatility as it s larger brother, but with a lower behindpanel depth. Electrical life 1 million actuations Modularity is at the heart of the design B2 Colour of LED illumination. M.series Axess, a ow-profile keypad offering design flexibility. 5 VDC, 240mA Illuminated versions: blue and yellow as standard, red, green, and white on request Dome version: < 1 Ohm 10kV with a metallic front plate -40 C to +85 C (-30 C for illuminated) -25 C to +85 C IP 65 (front face) IK 09 for standard versions with a 3mm 4.5N +/- 30% 0.5 ±0.3 mm 1 million actuations thick front plate (@+40 C) 56 days - UV resistance Shape Seize Dimension keys 12 Key Non illuminated version with A and B «Function» marking Non illuminated Non illuminated 11.6 x 11.6 Non illuminated Ø 15.6 Non illuminated 15 x Key YELLOW illuminated version A and B «Function» with marking Yellow illuminated Yellow illuminated 11.6 x 11.6 Yellow illuminated Ø 15.6 Yellow illuminated 15 x Key BLEU illuminated version with A and B «Function» marking Blue illuminated Blue illuminated 11.6 x 11.6 Blue illuminated Ø 15.6 Blue illuminated 15 x 15 Mounting element Bracket AXN12001 AXN12002 AXN12003 AXN12004 AXL12011 AXL12012 AXL12013 AXL12014 AXL12021 AXL12022 AXL12023 AXL12024 FIX.AX01 MOUNTING bracket: 2 mounting clips made of ABS polycarbonate FIX.AX01 TYPE OF STANDARD KEYS Standard colors: Natural aluminium, red, yellow and green Specific colors on request: blue, orange, anthracite grey.

4 S.series The 12 or 16 key S.series keypads are specially designed for public environment applications, such as vending machines, ticket machines, payment terminals, telephones, access control systems and industrial machinery. Electrical life 4 million actuations / key The S.series therefore has high resistance to impact and vandalism (IK10) and is also sealed to IP 67 KEYS: The metal anti pull-off keys are highly resistant to shock and fire. MARKING: Customised markings or symbols in different colours are available on request B3 12 Keys telephone Nominal 5 V, 5 ma : Maximum voltage 24 V Minimum voltage 0.5 V Minimum current 0.1 ma Illumination 20 ma at 2.1 V (yellow and green) 20 ma at 1.9 V (red) Current consumption for single LED: 10 ma at 3.4 V (blue) NOTE: A load resistor may need to be connected by the customer in order to power the LED correctly. Luminostity and wave length scattering caused by technologie used in the LED manufactering processes may lead to visual differences in our products 200 Ω 1000 MΩ at 100 VDC Electric strength 1500 Vrms, 50 Hz, 1 min., as per EN IEC Common point: -30 C C -25 C C IP 67 as per IEC 60529, mounted IK 10 (20J) 2 N ±1N 1.5 mm ±0.3 mm 4 million actuations : 40 ms 16 Keys, Hexadecimal (@+40 C) 10 days 12 Keys version with TELEPHONE marking Circuit Non Illuminated / Black Non Illuminated / Black Blue Illuminated «XY» Blue Illuminated «XY» Yellow Illuminated Yellow Illuminated «XY» 16 Keys version with HEXADECIMAL marking Common point: Circuit Non Illuminated / Black Non Illuminated / Black Blue Illuminated «XY» Blue Illuminated «XY» Yellow Illuminated Yellow Illuminated «XY» S S S S S S S S S S S S

5 S.series Lite The S.series Lite looks like a metal keypad, but the keys and housing are crafted from polycarbonate which is known for its incredible strength and high-impact resistance. It is also protected to IP67 against water, oil and dirt ingress and the metal-look finish is scratch-resistant to ensure long-lasting good Electrical life 4 million actuations / key KEYS: Polycarbonate (PC), metal-look MARKING: Precision marking using laser etching and marking. Customised markings or symbols on request. Nominal 5 V, 5 ma 12 Keys telephone : Maximum voltage 24 V Minimum voltage 0.5 V Minimum current 0.1 ma 5V (all colours) Illumination (by LED) blue and yellow as standard, red, green, and white on request 200 Ω 1000 MΩ at 100 VDC Electric strength 1500 Vrms, 50 Hz, 1 min., as per EN IEC Common point: -30 C C -25 C C IP 67 as per IEC 60529, mounted IK 09 2 N ±1N 1.5 mm ±0.3 mm 4 million actuations 40 ms (@+40 C) 16 Keys, Hexadecimal : 10 days 12 Keys version with TELEPHONE marking Circuit Non Illuminated / Black Non Illuminated / Black «XY» Blue Illuminated Blue Illuminated «XY» Yellow Illuminated Yellow Illuminated «XY» 16 Keys version with HEXADECIMAL marking Circuit Non Illuminated / Black Non Illuminated / Black «XY» Blue Illuminated Blue Illuminated «XY» Yellow Illuminated Yellow Illuminated «XY» SL SL SL SL SL SL SL SL SL SL SL SL Common point: B4 22

6 A.series The low profile 12 or 16 key A.series keypads are specially designed for public environment applications, such as vending machines, ticket machines, payment terminals, telephones, access control systems and industrial machinery. Electrical life1 Million actuations / key The aluminum keys are available with either flat or concave profile Anti-pull-of and resistant to shock and fire Full IP67 front face sealing B5 Nominal 24 V, 50 ma Maximum voltage 50 V Minimum voltage 5 V Minimum current 1 ma 1 Ω 1000 MΩ at 100 VDC Electric strength 1500 Vrms, 50 Hz, 1 min., as per EN IEC C to +85 C (-30 C for illuminated) -25 C to +85 C IP 67 as per IEC IK N ±30% 1 mm ±0.2 mm 1 million actuations 1 ms (@+40 C) 48 Hours 10 days Aluminium natural key cap Keys dimension 12 Key version with FUNCTION «A and B» marking «XY» «XY» Common point «PC» Common point «PC» AAN12001 AAN12011 AAN12051 AAN Key version with TELEPHONE marking «XY» «XY» Common point «PC» Common point «PC» 16 Key version with HEXADECIMAL marking «XY» «XY» AAN12005 AAN12015 AAN12055 AAN12065 AAN16001 AAN16011 MOUNTING

7 ECO.series The ECO keypads are suited to all indoor applications including data-entry systems, remote controls, telephone, point of sales terminals or alarm systems. The ECO range of low-cost, flush-mount keypads are rugged, economical devices available in 12-key telephone style and 16-key hexadecimal layouts. Electrical life1 Million actuations / key B6 Nominal 24V, 20 ma Maximum voltage 24 V Minimum voltage 500 mv Minimum current 10 ma 200 Ω MΩ at 100 VDC Switch rating 0.5 W -40 C C -20 C C IP 40 IK N ±35% 1.4 MM ±0.1N 1 million actuations 2 ms Packaging of 10 pcs 12 Key version with TELEPHONE marking Key cap Common point «PC» plastic white «XY» plastic white 16 Key version with HEXADECIMAL marking Common point «PC» plastic white «XY» plastic white ECO ECO ECO ECO

8 W.series The EOZ W.series range is specially designed for hostile environments. Built from stainless steel and chrome plated zinc alloy (zamak), the W.series therefore has a high resistance to impact and vandalism and is also sealed to IP67 from the front. Electrical life 4 Millions actuations / key B7 Nominal 5 V, 5 ma Maximum voltage 24 V Minimum voltage 0.5 V Minimum current 0.1 ma Illumination Current consumption for single LED: 20 ma at 2.1 V (yellow and green) 20 ma at 1.9 V (red) 200 Ω 1000 MΩ at 100 VDC Electric strength 1500 Vrms, 50 Hz, 1 min., 10 ma at 3.4 V (blue) as per EN IEC C C -25 C C as per IEC IP 67 IK 10 (20J) 2 N ±1N 1.5 mm ±0.3 mm 4 million actuations 40 ms (@+40 C) 10 days 4 Keys version Marking Yellow Illuminated A, B, C, D Non illuminated Arrow Non illuminated Without Numbers W.0400X.016 W.0400X.038 W.0400X.P01 MOUNTING

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Date: 2016.3.24 Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Symbol Amended Reason Pages Date Corrector Amendment No Approved by Checked by Drawn by Designed by UST-10LN Specification

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 113 Sensor SERIES Related Information General terms and conditions... F-7 About laser beam... P.199~ Sensor selection guide... P.1~ General precautions... P.11 PHOTO PHOTO PARTICUR MEASURE ITY panasonic.net/id/pidsx/global

More information

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION FIRE DETECTION >FIRE DETECTION CONVENTIONAL C400 SYSTEM FIRE DETECTION EFFICIENT AND MODULAR Elkron fire detection systems protect your business and grow with it Elkron's conventional fire detection range

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11

More information

Series. Robust and attractive.

Series. Robust and attractive. Series 82 Robust and attractive. www.eao.com Series 82 Robust and attractive. With Series 82, EAO offers the optimal pushbutton for vandal-resistant, stylish HMI controls used in harsh industrial environments,

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 13 Sensor SERIES Related Information General terms and conditions... F-17 About laser beam... P.13~ Sensor selection guide... P.967~ General precautions... P.1 PHOTO PHOTO Conforming to EMC Directive Conforming

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

Series. Unique PCB mounting system.

Series. Unique PCB mounting system. Series 71 Unique PCB mounting system. www.eao.com Series 71 Unique PCB mounting system. Unique printed circuit board (PCB) technology enables the Series 71 to provide versatile and modular opportunities

More information

Half-Dome. the Design-Tower. Compact

Half-Dome. the Design-Tower. Compact the Design-Tower 81 Compact 82 compact signal towers Visual-audible LED signal tower system in semicircular design Modern signal tower design Available to order pre-configured or with customised tower

More information

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers 687 Optical Touch Switch SW-1 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Conforming to OSHA / ANSI Listing MEASURE panasonic.net/id/pidsx/global

More information

Sylproof Superia LED G2

Sylproof Superia LED G2 Range Features 665mm, 1265mm, 1565mm single and twin weatherproof LED luminaires Impresive performance, up to 7,837lm (luminaire lument output on 80W twin / double version) High efficiency, will help you

More information

ISIS SAFETY SYSTEM Installation guide

ISIS SAFETY SYSTEM Installation guide ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly

More information

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional

More information

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System Low Profile - Less than 25 mm Precision Machined Interlock Mounting System Special Anti-Slip Coating Upgrading Helicopter deck signalisation lighting

More information

Series. Attractively tough.

Series. Attractively tough. Series 82 Attractively tough. Series 82 Attractively tough. With the Series 82, EAO offers the optimal pushbutton for vandal resistant, attractive HMI controls used in harsh industrial environments, rugged

More information

Waterproof TCW060 just light

Waterproof TCW060 just light Lighting Waterproof TCW060 just light TCW060 Designed for use in demanding environments, TCW060 is an economical, compact waterproof luminaire. Dedicated versions are available for TL-D and TL5 lamps.ingressprotected

More information

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p FIRE AND SAFETY Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p15-10 Perth (08) 9248 0410 Sydney (02) 9676 1671 Melbourne (03)

More information

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE / 3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors

More information

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document 1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need for

More information

+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications

+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications + = ECO-STAR System Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) STAR Technical Specifications - Degree of protection: IP65. - Resistance to impact: IK08. - Glow wire

More information

FSLIMPRO

FSLIMPRO 1. INTRODUCTI FSLIMPRO is especially designed and built for quick and easy installation. Installation is truly made easy and wiring up is minimised (only the power supply cable and alarm contacts require

More information

Industrial Signalling

Industrial Signalling Industrial Signalling Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place. Product Range

More information

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories interactive, AnalogPLUS/SynoLOOP, collective/synoline600 AlgoRex Synova TM Base made of impact and scratch-proof plastic Screw less terminals

More information

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

FIREBETA EXTINGUISHING CONTROL PANEL (ECP) F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas

More information

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors More Precision indusensor // Linear inductive displacement sensors 14 Long-stroke sensors for hydraulics & pneumatics indusensor EDS - Measurement ranges 75... 630mm - Linearity ±0.3% FSO - Integrated

More information

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content 8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity

More information

FlexiSmoke WSC 520 / WSC 540 / WSC 560 Modular smoke ventilation panel 20-60A

FlexiSmoke WSC 520 / WSC 540 / WSC 560 Modular smoke ventilation panel 20-60A Version 11 Controls for smoke and natural ventilation WSC 520 2 x WSA 017 WSC 540 4 x WSA 017 WSC 560 6 x WSA 017 2.20 Flexi WSC 520 / WSC 540 / WSC 560 odular smoke ventilation panel 20-60A Natural ventilation

More information

More Precision. thermometer // Non-contact IR temperature sensors

More Precision. thermometer // Non-contact IR temperature sensors More Precision thermometer // Non-contact IR temperature sensors 48 Compact OEM infrared sensor with external controller thermometer CSmicro thermometer CSmicro Miniature OEM infrared temperature sensor

More information

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays To Be Discontinued IEC62055-31 UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays DZ RELAYS (ADZ) New New Horizontal terminal type FEATURES 1. IEC62055-31 UC3 compliant (short current

More information

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign Features DATASHEET Connects to multiple sensing instruments One/Two Channel Device Bright solid state LED Alarm Display Audible Alert (internal and external) High reliability, fully dual redundant alarm

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

Fibox FTTH Solutions

Fibox FTTH Solutions Fibox FTTH Solutions Solutions for your FTTH/FTTX enclosing needs Fibox is the leading innovator in developing enclosure solutions to protect your electrical and optical components and systems in hostile

More information

MEDIVA LED. Normal care / Horizontal Bed head units. Dynamic Lighting

MEDIVA LED. Normal care / Horizontal Bed head units. Dynamic Lighting MEDIVA T5 LED Dynamic Lighting Normal care / Horizontal Bed head units STRENGTHS + Easy maintenance + Design & Ergonomics + Personalisation MEDIVA s separate compartment for medical gas provide quick and

More information

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC MEMS Air Velocity Sensor Unique dust separating structure, developed by OMRON, in a compact and highly efficient FLOW-SENSOR. Unique dust segregation structure. +/-10% Full-Scale repeatable accuracy achieves

More information

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors More Precision indusensor // Linear inductive displacement sensors 18 Long-stroke sensors for hydraulics & pneumatics indusensor EDS - Measurement ranges 75... 630mm - Linearity ±0.3% FSO - Integrated

More information

OPTISENS TUR 2000 Technical Datasheet

OPTISENS TUR 2000 Technical Datasheet OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) IR425-D4_D00039_04_D_XXEN/05.2017 ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012670 / 08.2013 isopv425

More information

ALARMLINE ANALOGUE Linear Heat Detection System

ALARMLINE ANALOGUE Linear Heat Detection System ALARMLINE ANALOGUE Linear Heat Detection System Alarmline Analogue cable senses temperature variations by continuously monitoring the resistance of specially doped Negative Temperature Coefficient (N.T.C.)

More information

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID) Open-area Smoke Imaging Detection (OSID) OSID Smoke Detection Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual

More information

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

Topscan G3 Presence detector for automatic doors

Topscan G3 Presence detector for automatic doors Topscan G3 Presence detector for automatic doors Your added value! Smallest presence detector of its class User-friendly, solid and simple operation Easy and significantly faster installation Mechanically

More information

Sounder AX03, AX05. Loud signalling device with 32 different signals. Application. Design. Signalling devices with good directivity

Sounder AX03, AX05. Loud signalling device with 32 different signals. Application. Design. Signalling devices with good directivity FUNKE+HUSTER FERNSIG Sounder AX03, AX05 Loud signalling device with 32 different signals 3 AC and DC versions 3 High volume up to 112 db(a) 3 Low current consumption 3 Choice of 32 different signal tones

More information

Laser Collimated Beam Sensor

Laser Collimated Beam Sensor SERIES Laser Collimated Beam Sensor Class 1 Laser Beam Sensor Safe for Your Eyes Marked Conforming to EMC Directive (Excluding LA-C1) Safe Laser Beam This laser collimated beam sensor conforms to the Class

More information

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF... Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF... 4 TH Generation TRIPLESHIELD TM Adjustable sensing distance: 2-10 mm Flush or 3- mm Non-flush Protection: short-circuit,

More information

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V IR1575_D00116_00_D_XXEN/05.2015 Insulation monitoring device for unearthed AC/3(N)AC systems up to 480

More information

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF... Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF... 4TH Generation TRIPLESHIELD TM Adjustable sensing distance: 2-20 mm flush or 4-30 mm non-flush Protection: short-circuit,

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature 1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21... Use Type summary Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for relative humidity Signal output

More information

Version 4 Controls for smoke and natural ventilation. CompactSmoke WSC 310 / WSC 320 PLUS Smoke control panel 10-20A

Version 4 Controls for smoke and natural ventilation. CompactSmoke WSC 310 / WSC 320 PLUS Smoke control panel 10-20A Version 4 Controls for smoke and natural ventilation 1.55 CompactSmoke WSC 310 / WSC 320 PLUS Smoke control panel 10-20A Natural ventilation Smoke ventilation EN 12101 Rated voltage Maksimal output current

More information

TECHNICAL SHEET. About the product

TECHNICAL SHEET. About the product No. 533/ 07.01.2015, Edition No. 9, 1/5 Outdoor decorative luminaire SYSTEM WITH AVIS- 02-9W LED / AVIS-02M-9W LED SYSTEM WITH AVIS-02-9W LED SYSTEM WITH AVIS-02-9W LED + POWER SUPPLY CONNECTION About

More information

Instruction Manual December 2001 ENACOCU02

Instruction Manual December 2001 ENACOCU02 SENACOCU02 Instruction Manual December 2001 ENACOCU02 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance. RFID Non-contact Safety Switches RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance. Based on RFID technology,

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

Auer - Signal tower ECO Ø70 mm modular

Auer - Signal tower ECO Ø70 mm modular products Panel Signalling Signal Towers - Auer Auer - Signal tower ECO Ø70 mm modular Modular system with bayonet fitting for quick assembly LED or conventional filament lamp for cost sensitive applications

More information

I Notification. Loudspeaker HONEYWELL COMMERCIAL VOICE ALARM AUDIO

I Notification. Loudspeaker HONEYWELL COMMERCIAL VOICE ALARM AUDIO I Notification Loudspeaker HONEYWELL COMMERCIAL VOICE ALARM AUDIO Honeywell is a Fortune 100 company that invents and manufactures technologies to address tough challenges linked to global macro trends

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DUAL MONITORED INPUT/OUTPUT UNIT BN-305 DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

DIGITAL INDICATOR DI25

DIGITAL INDICATOR DI25 DIGITAL INDICATOR DI25 Operating instructions Preface Thank you for purchasing our digital indicator DI25. This manual contains instructions for the mounting, functions, operations and notes when operating

More information

CoreLine Waterproof the clear choice for LED

CoreLine Waterproof the clear choice for LED Lighting CoreLine Waterproof the clear choice for LED CoreLine Waterproof Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light

More information

Machine Protection Door Albany RP300. ASSA ABLOY Entrance Systems

Machine Protection Door Albany RP300. ASSA ABLOY Entrance Systems Machine Protection Door Albany RP300 ASSA ABLOY Entrance Systems Albany RP300 Rapid opening and closing ensures short cycle times up to 5 cycles per minute High reliability even after years of high numbers

More information

Machine Protection Door

Machine Protection Door Machine Protection Door ASSA ABLOY RP2000 ASSA ABLOY Entrance Systems ASSA ABLOY RP2000 Type tested machine protection door with aluminum door blade Safety limit switches according to EN ISO 13849-1 and

More information

T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE /

T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE / 2 T M LIM2010 Line Isolation Monitor (LIM) Technical Bulletin NAE2022011 / 04.2015 Line Isolation Monitor LIM2010 Description The LIM2010 Line Isolation Monitor (LIM) measures the Total Hazard Current

More information

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10

More information

STYLAGE STYLE And PErformAncE for A new AGE modern EfficiEnT SmArT STYLiSh

STYLAGE STYLE And PErformAncE for A new AGE modern EfficiEnT SmArT STYLiSh Style and Performance FOR a New Age Modern Efficient Smart Stylish The missing link between tradition and modernism With its typical 4-faced design, the luminaire brings classical style lanterns into the

More information

WE-EF LIGHTING USA QLS400 [R45] SERIES Wall luminaires surface mounted 2018

WE-EF LIGHTING USA QLS400 [R45] SERIES Wall luminaires surface mounted 2018 WE-EF LIGHTING USA QLS400 [R45] SERIES Wall luminaires surface mounted 2018 1 WE-EF is a global manufacturer of high-performance exterior luminaires renowned for outstanding engineering design and innovative

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W Comfort Ceiling Fan Coil System INDULVENT ec NEW Draught-free ambient air distribution with cooling capacity up to 2600 W Low sound power levels Only electrical, cooling water and condensate connections

More information

Long-Range Barrier Sensors

Long-Range Barrier Sensors Troubleshooting: Receiver LED never turns ON and the buzzer never sounds Buzzer does not sound if the sensor is triggered Receiver LED is ON and the buzzer sounds all the time Test the power and ground

More information

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Sounders Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Pg 185 186 187 188 189 190 191 Y03 1YA030207 1YA030203 1YA030205 YL030/24 A1:2002 YL030110/230 UL464 C22.2 No. M1983 BS

More information

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents lcoswitch DIP switches are available in standard single pole, single throw; side actuated, single pole, single throw and multiple series versions. Contacts are made of high strength copper alloy with.000030

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with. JEDI Powerful adjustable linear LED projector Concept: Powerful adjustable linear LED projector. Materials: Extruded 18μ anodized aluminum body. Extra clear 4mm thick glass flat screen. Painted black die-cast

More information

AlarmLine Addressable Linear Heat Detector

AlarmLine Addressable Linear Heat Detector Line Addressable Linear Heat Detector P/N 7-0001-00 Effective: March 2008 K-7-02 FEATURES UL Listed FM Approved CSFM MEA (pending) Low-cost interface between Line sensor cable and control panel accepting

More information

MVG. Modular Vacuum Grippers. US5

MVG. Modular Vacuum Grippers.   US5 Modular Vacuum Grippers MVG www.coval.com US5 MVG COVAL s MVG Series: Customized Customized Solution COVAL s MVG series vacuum grippers correspond perfectly to the expectations of integrators and users:

More information

Cornered Ci2. Description FEATURES. 2 1/2 woofer 3/4 dome tweeter Triangular ABS cabinet IP54 rated Mounts without brackets Hidden cable connection

Cornered Ci2. Description FEATURES. 2 1/2 woofer 3/4 dome tweeter Triangular ABS cabinet IP54 rated Mounts without brackets Hidden cable connection Cornered Ci2 FEATURES 2 1/2 woofer 3/4 dome tweeter Triangular ABS cabinet IP54 rated Mounts without brackets Hidden cable connection COLOURS Description DATA Ci2 is an ultra compact 2-way full-range speaker

More information

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS. OLUX LED Flood Light Datasheet OLUX LED FLOOD is a cost-effective, durable and environmentally-preferable LED flood light series. The IP66 outdoor rated OLUX LED FLOOD S, M and L are designed to replace

More information

Introducing the. Subklew SM24 Mosaic System

Introducing the. Subklew SM24 Mosaic System Introducing the Subklew SM24 Mosaic System The Subklew Mosaic Mimic System from TEW is still the best available and has maintained its engineering integrity in precision and quality since the day it was

More information

Ci130ER. Architectural Speaker. Product Overview. Key Features. Architect and Engineer Specifications

Ci130ER. Architectural Speaker. Product Overview. Key Features. Architect and Engineer Specifications Product Overview The KEF Ci130ER is a high performance speaker designed for in-ceiling and flush mount installations. It s a coincident point source design featuring KEF s proprietary sit-anywhere Uni-Q

More information

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE Insulation monitoring device with integrated load and temperature monitoring and locating current injector for insulation fault location systems for medical IT systems _D00043_02_D_XXEN/09.2016 Insulation

More information

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21 Operating voltage AC 24 V / DC 13535 V Signal output DC 010 V / 420 ma for relative humidity Signal output DC 010 V / 420 ma

More information

Public Address Project Combisound System

Public Address Project Combisound System Public Address Project Combisound System Roberto Bono sat@eissound.com 900502285 Index Introduction:... 2 General description... 3 Technical descriptions:... 4 Public Address Central Unit... 4 Loudspeakers,

More information

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments Outdoor Enclosures Outdoor Enclosures Protected like a bunker for all harsh environments sales@mcldatasolutions.co.uk +44(0)1702 443810 mcldatasolutions.co.uk Outdoor enclosures and climate control components

More information

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm VIMPEX Sounder Range Fire Alarms Banshee Electronic Sounders FlashDome EN 54-3 Evacuation Audible Alarm BS 5839-1 Beacons The range of sounders, beacons, sounder beacons and accessories represents the

More information

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES KEY FEATURES Hermetically sealed intrinsically safe. Operates in explosive/harsh environments without oxidation or contamination of contacts, including long periods of non-operation 8kV isolation between

More information

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated 6 available sizes Integral suction lifter Accessories Lightning fast suction for lifting and moving with only on vaccum line s Vacuum-operated Integral suction lifter Compressed-air Page 3-01.. Page 3-02..

More information

Installation & User Manual V1.1

Installation & User Manual V1.1 Other products from GSD standalone products GSD also offers fully functional standalone door controls for less complex door management. This attractive design, with modern aesthestics, will complement

More information

More Precision. indusensor Linear inductive displacement sensors

More Precision. indusensor Linear inductive displacement sensors More Precision. indusensor Linear inductive displacement sensors - 1 - Standard sensors 4 LVDT series - gauges with external controller Proven LVDT technology Measuring ranges ±1 ±10mm Excellent price/performance

More information

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller No. CP-SS-7E Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD00C Advanced Ultraviolet Flame Detector. This AUR300C controls

More information

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA MX1A and MX1B: Laser Displacement Detection MX1A and MX1B: Laser Displacement Detection Built-in math capabilities available (MX1B only) Digital display on amplifier; easy setting and monitoring (MX1B

More information

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series DESCRIPTION The SZL-VL-S Series miniature-type limit switch is designed for use in applications where limited space is available. With IP67

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

CONTENTS NBM-06 Bell (6") Page 1

CONTENTS NBM-06 Bell (6) Page 1 CONTENTS NBM-06 Bell (6") - - - Page 1 NBM-08 Bell (8") - - - Page 1 LFB-24 Sounder Banshee - Page 2 VCT--NT Base Version Sounder Page 2 VCT--NT Wall Version Sounder Page 2 VRS1-R or W Bedhead Sounder

More information

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction Product Introduction NCF series centrifugal fan forced draft cooling tower is a type of cooling tower designed to protect the environment from our years of cooling tower equipment design, production, operation,

More information

EFBW series - BiWire Ultra control panel

EFBW series - BiWire Ultra control panel 4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional

More information

Instruction Manual August sitrans CU 02

Instruction Manual August sitrans CU 02 Instruction Manual August 2005 sitrans CU 02 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with. JEDI Powerful adjustable linear LED projector Concept: Powerful adjustable linear LED projector. Materials: Extruded 18μ anodized aluminum body. Extra clear 4mm thick glass flat screen. Painted black die-cast

More information

GOBLET. Urban Lighting Luminaire. Registered models - Design Massimo Sacconi

GOBLET. Urban Lighting Luminaire. Registered models - Design Massimo Sacconi GOBLET Urban Lighting Luminaire Registered models - Design Massimo Sacconi (ha il filo ingrossato) GOBLET has been designed with the most classic urban environments in mind. The product, offered in one

More information