Test of TrafiCam vehicle detector in Winchester

Size: px
Start display at page:

Download "Test of TrafiCam vehicle detector in Winchester"

Transcription

1 PPR434 Test of TrafiCam vehicle detector in Winchester K Wood

2

3 Transport Research Laboratory PUBLISHED PROJECT REPORT PPR434 Test of Traficam vehicle detector in Winchester by K Wood (TRL) Prepared for: Project Record: PPRO 04/16/17 Client: Emerging detector technologies Department for Transport, Traffic Management Division (Suku Phull) Copyright Transport Research Laboratory August 2009 This Published Report has been prepared for the Department for Transport. Published Project Reports are written primarily for the Client rather than for a general audience and are published with the Client s approval. The views expressed are those of the author and not necessarily those of the Department for Transport. Name Date Approved Project Manager A Kirkham 19/08/2009 Technical Referee I J Burrow 19/08/2009

4 When purchased in hard copy, this publication is printed on paper that is FSC (Forestry Stewardship Council) and TCF (Totally Chlorine Free) registered. TRL PPR434

5 Contents Executive summary i Abstract 1 1 Introduction 1 2 Test site and installation 3 3 Data collection and analysis SCOOT data collection Data analysis 7 4 Results 9 5 Conclusions 13 Acknowledgements 13 TRL PPR434

6 TRL PPR434

7 Executive summary The Department for Transport commissioned TRL to assist in the development of vehicle and pedestrian systems for urban traffic management. One of the strands of the work is to assess the performance of new detection systems. Hampshire County Council kindly provided a test site in Winchester where trial detectors could be mounted on a lamp column adjacent to a SCOOT loop and the output from the trial detector returned to the SCOOT computer for off-line comparison with the output of the inductive loop detector. A TrafiCam video detector was installed on the lamp column and connected to the SCOOT computer via the Out-station Transmission Unit in the signal controller. The output from the TrafiCam detector was configured in SCOOT to be associated with a dummy link that had no effect on the optimisation of the signal timings. Associating the detector with a SCOOT link allowed the use of SCOOT messages to monitor the output of the detector. Standard SCOOT messages giving the status (off or on) of the TrafiCam and the corresponding SCOOT loop were recorded and analysed. The conclusions from the analysis were: The overall agreement between the TrafiCam and the inductive loop was good. The TrafiCam detection system tested for SCOOT seemed to work well in comparison with a loop system. Because of the need for the TrafiCam to see the rear lights of vehicles, its detection zone was not coincident with the inductive loop. Therefore, comparison of individual vehicle counts in slow moving traffic was more difficult than it would have been with coincident detection zones. Nevertheless, 99% of individual vehicle detections were matched. Total occupancy recorded by the TrafiCam was about 10% greater than the loop. Some of this difference could have been due to a slightly longer effective detection zone. In addition, the TrafiCam detection zone was downstream of the loop and, therefore, more likely to be queued in, resulting in more vehicles being delayed in its detection zone, hence greater occupancy than over the loop. The SCOOT validation process would allow for a small difference in the length of the detection zone, which would then have no practical effect on the operation of SCOOT. There were some differences in the outputs of the two detectors when traffic was queuing back to the detector zones. Some of the differences could be explained in terms of the difference in detection zones, but in a very few cases it appeared that the TrafiCam might have stuck on for some time (up to half a minute) during which the loop detected several vehicles. TRL i PPR434

8 TRL ii PPR434

9 Abstract A TrafiCam video vehicle detector was installed adjacent to a standard SCOOT inductive loop detector in Winchester. Outputs from the two detectors were returned to SCOOT and recorded for analysis. The inductive loop output was used in the SCOOT control algorithms as normal, but the trial TrafiCam detector was ignored by them. The status of both detectors, off or on, each quarter second was output in standard SCOOT messages and compared. The comparison was complicated as it was necessary to define the TrafiCam detection zone slightly downstream of that of the loop, but it was possible to make valid comparisons. 1 Introduction The Department for Transport commissioned TRL to assist in the development of vehicle and pedestrian systems for urban traffic management. One of the strands of the work is to assess the performance of new detection systems. Hampshire County Council kindly provided a test site in Winchester where trial detectors could be mounted on a lamp column adjacent to a SCOOT loop and the output from the trial detector returned to the SCOOT computer for off-line comparison with the output of the inductive loop detector. TRL 1 PPR434

10 TRL 2 PPR434

11 2 Test site and installation The test site is on the Romsey Road in Winchester at its junctions with Battery Hill and Kings School, see Figure 2-1. Figure 2-1: Winchester test site The lamp column is conveniently situated opposite the loop for traffic travelling south away from Winchester, ideal for testing side-fire detectors, and the signal controller is behind the bushes. However, the TrafiCam does not operate in true side-fire as the best performance for night-time operation is to view the rear lights of vehicles. Therefore, the detector was mounted on the lamp column looking slightly downstream of the loop. The resulting difference in detection times, TrafiCam activated slightly after the loop, was allowed for in the analysis of the results. The mounting bracket was attached to the lamp column by metal bands and the camera detector attached to the bracket using the standard short metal rod, see Figure 2-2. The camera lens is difficult to discern in the photo, but is a small circle about 2 cm diameter and the camera enclosure is 10 cm in diameter. Details of the unit are available on the web site At the test site, the unit was installed at between 4 and 5 metres high, giving an adequate view for one lane of traffic. A junction box connected by armoured cable to the controller had been installed at the site and the TrafiCam was wired into this box. TRL 3 PPR434

12 Figure 2-2: TrafiCam The interface card was installed in the controller and connected to the feeder cable. The camera communicates to the interface card using RS485. A laptop PC running the custom set up software was connected to the interface card and a camera image downloaded to it. The required detection zone was drawn on the image. After the detector and interface had been fully configured the detector was initiated. Operation of the unit was checked both through the interface and by comparing the operation of the LED on the camera housing with vehicles passing through the zone. The final verification of the performance was performed by recording the operation of the detector and a video image of the detection zone for several hours on the PC for later review. The detector had been set up in daylight, but the Traficon engineer was keen to check that the parameters for night-time detection were set correctly to operate on tail lights with the site ambient lighting. Figure 2-3 and Figure 2-4 show two screen shots from the PC TRL 4 PPR434

13 with the detection zone shown in green. The arrow shape at the top of the zone is an indicator that the detection zone is direction sensitive. Only vehicles travelling in that direction, or stopped vehicles that were travelling in that direction, are detected. Figure 2-3: Daylight screen shot TRL 5 PPR434

14 Figure 2-4: Night time screen shot 3 Data collection and analysis 3.1 SCOOT data collection The TrafiCam interface card in the controller was connected to the Outstation Transmission Unit (OTU) and the detector output returned to the central SCOOT controller together with those of all the other detectors connected to that controller. The SCOOT data was configured so that the TrafiCam output was associated with a dummy link at the same node as the nearby SCOOT loop. That link was monitored by SCOOT, but not used by any of the optimisers and so it had no influence on the signal operation. However, as a fully configured SCOOT link all the SCOOT link and detector based messages were available. In particular the M19 message that gives details of the detector state could be recorded for analysis. In a SCOOT system the OTU samples each detector every quarter of a second to take a snapshot of its status, on in which case a 1 is sent to SCOOT, or off when a 0 is sent. For each detector, four bits indicating the detector status for the last second are returned to SCOOT every second. These four bits can be output in the M19 message. An example is shown below for data recorded on the 18 th February: ****** Start of SCOOT log for 18-FEB-09 ****** We 12:00:00 M19 N42121B1 DETECTOR STATE 0000 We 12:00:01 M19 N42121B1 DETECTOR STATE 0000 We 12:00:02 M19 N42121B1 DETECTOR STATE 0000 We 12:00:03 M19 N42121B1 DETECTOR STATE 0000 TRL 6 PPR434

15 We 12:00:04 M19 N42121B1 DETECTOR STATE 0000 We 12:00:05 M19 N42121B1 DETECTOR STATE 0000 We 12:00:06 M19 N42121B1 DETECTOR STATE 0000 We 12:00:07 M19 N42121B1 DETECTOR STATE 0000 We 12:00:08 M19 N42121B1 DETECTOR STATE 0000 We 12:00:09 M19 N42121B1 DETECTOR STATE 0000 We 12:00:10 M19 N42121B1 DETECTOR STATE 0000 We 12:00:11 M19 N42121B1 DETECTOR STATE 0000 We 12:00:12 M19 N42121B1 DETECTOR STATE 0000 We 12:00:13 M19 N42121B1 DETECTOR STATE 0111 We 12:00:14 M19 N42121B1 DETECTOR STATE 0000 We 12:00:15 M19 N42121B1 DETECTOR STATE 1110 We 12:00:16 M19 N42121B1 DETECTOR STATE 0001 We 12:00:17 M19 N42121B1 DETECTOR STATE 1000 We 12:00:18 M19 N42121B1 DETECTOR STATE 0000 We 12:00:19 M19 N42121B1 DETECTOR STATE 0000 We 12:00:20 M19 N42121B1 DETECTOR STATE 0000 A message is output each second for each detector for which the message is turned on. The format of the message is: Two letters to denote the day of the week, in this example, Wednesday The time, hh:mm:ss The message identifier (M19) Detector reference number (node N42121, link B, first detector on the link) Detector state in the previous second starting with the first quarter second, 0=off, 1=on In the 21 seconds shown above three vehicles were detected: Vehicle 1 detected in the last 3 quarter seconds of the 12:00:13 message Vehicle 2 detected in the first 3 quarter seconds of the 12:00:15 message Vehicle 1 detected in the last quarter second of the 12:00:16 message and the first quarter second of the 12:00:17 message The M19 message was logged for the TrafiCam detector and the neighbouring inductive loop. 3.2 Data analysis SCOOT uses both the flow of vehicles (a new vehicle is indicated by an off to on transition in the detector status) and the length of time each vehicle activates the detector (occupancy for each vehicle). Therefore, the data analysis was designed to analyse the data in detail, to count individual discrepancies between detection of a vehicle by each detector rather than total flow in an hour, for example. As noted in the description of the site, the detection zones for the loop and TrafiCam were not coincident due to the need of the TrafiCam to view the rear of vehicles for night-time detection. The distance between the detection zones was constant, but the time between detection in the two zones was not. At busy times, queues build back towards the junction from the next junction downstream, slowing vehicles in the vicinity of the detectors. Therefore, at some times the start of detection of a vehicle at the inductive loop will be well in advance of detection by the TrafiCam. At other times the difference in initial detection will be much shorter. TRL 7 PPR434

16 Under free-flow conditions, the difference in detection times was less than a second. Therefore, a vehicle detection by the TrafiCam within one second of a detection by the loop was classified as a successful detection by both detectors. However, a second criterion was needed for congested conditions. A vehicle could be delayed by the queue and remain stationary, detected by the loop for some time before moving into the detection zone of the TrafiCam. However, when it started to move, it would be expected to enter the TrafiCam s detection zone soon after leaving that of the inductive loop. Therefore, the second criterion for successful detection was defined to be detection by the TrafiCam within half a second of ceasing to be detected by the loop. Three categories of TrafiCam detection were defined: 1. Successful detection: Start of detection by the TrafiCam within 1 second of the start of detection by the inductive loop Or start of detection by the TrafiCam within ½ second of the end of detection by the inductive loop 2. False positive: Detection by the TrafiCam without a detection by the inductive loop meeting either of the above criteria 3. False negative: Detection by the inductive loop without a detection by the TrafiCam meeting either of the above criteria In addition to counting successful detections, false positives and false negatives, the total occupancy and occupancy per vehicle were calculated. TRL 8 PPR434

17 4 Results The overall results are summarised in Table 4-1. The matches, false positives and false negatives are as defined above. In congested conditions it is possible that the time lag between a small vehicle leaving the inductive loop and entering the TrafiCam detection zone could have been greater than 0.5 seconds, resulting in both a false negative and a false positive being recorded. Therefore, the match rate may be slightly higher than the 99.0% quoted in the table. The column headed ratio is the ratio of the TrafiCam result to the relevant inductive loop data, e.g. the false positives amount to 0.9% of the vehicles counted by the inductive loop. Table 4-1: Summary results Inductive loop TrafiCam Ratio Vehicle count (vehicles) % Occupancy (s) % Matches % False positives % False negatives % These results are generally good and give confidence that the TrafiCam would normally provide good information to SCOOT. The detector occupancy is noticeably higher for the TrafiCam than the loop, which is not intrinsically a problem as some latitude is allowed in the length of the detection zone and catered for in the SCOOT validation process. However, examining the data in detail showed that there were occasions when the TrafiCam appeared to stick in the on state compared with the loop. There was a suspicion that on some occasions the appearance of a new vehicle, according to the loop, caused the TrafiCam to resume normal operation. It was noted that the inductive loop appeared to have an upper limit on its occupancy of 3.5 seconds in most of the data collected. The presence time of the detector should be much longer than this to register congestion and allow SCOOT to respond. It was not possible from the data to be sure that there was not a problem with the loop causing problems with comparison of the detectors in congested conditions. However, in some cases where the TrafiCam was on for considerably longer than the loop it was possible to rationalise the discrepancy in terms of the difference in detector zone along the road. The TrafiCam detection zone was further from the upstream junction, and therefore closer to the downstream junction, than the loop. Therefore, queues from the downstream junction were more likely to affect the TrafiCam detection zone than the loop. An example below shows vehicles highlighted on the two detectors. It appears that the queue just reaches to the loop, but it delays some vehicles more slightly downstream in the TrafiCam detection zone. The third vehicle is detected for 6 seconds by the TrafiCam, when that one clears the detection zone, the fourth vehicle leaves the loop, coincidentally after 3.5 seconds of occupancy. TRL 9 PPR434

18 Loop Tu 11:55:23 M19 N42121B1 DETECTOR STATE 0000 Tu 11:55:24 M19 N42121B1 DETECTOR STATE 1110 Vehicle 1 Tu 11:55:25 M19 N42121B1 DETECTOR STATE 0000 Tu 11:55:26 M19 N42121B1 DETECTOR STATE 0000 Tu 11:55:27 M19 N42121B1 DETECTOR STATE 0111 Vehicle 2 Tu 11:55:28 M19 N42121B1 DETECTOR STATE 1110 Tu 11:55:29 M19 N42121B1 DETECTOR STATE 0111 Vehicle 3 Tu 11:55:30 M19 N42121B1 DETECTOR STATE 1111 Tu 11:55:31 M19 N42121B1 DETECTOR STATE 1100 Tu 11:55:32 M19 N42121B1 DETECTOR STATE 0000 Tu 11:55:33 M19 N42121B1 DETECTOR STATE 1111 Vehicle 4 Tu 11:55:34 M19 N42121B1 DETECTOR STATE 1111 Tu 11:55:35 M19 N42121B1 DETECTOR STATE 1111 Tu 11:55:36 M19 N42121B1 DETECTOR STATE 1100 Tu 11:55:37 M19 N42121B1 DETECTOR STATE 0000 Tu 11:55:38 M19 N42121B1 DETECTOR STATE 0000 Tu 11:55:39 M19 N42121B1 DETECTOR STATE 0000 Tu 11:55:40 M19 N42121B1 DETECTOR STATE 1111 Vehicle 5 Tu 11:55:41 M19 N42121B1 DETECTOR STATE 1000 Tu 11:55:42 M19 N42121B1 DETECTOR STATE 0000 TrafiCam Tu 11:55:24 M19 N42121Z1 DETECTOR STATE 0011 Vehicle 1 Tu 11:55:25 M19 N42121Z1 DETECTOR STATE 1110 Tu 11:55:26 M19 N42121Z1 DETECTOR STATE 0000 Tu 11:55:27 M19 N42121Z1 DETECTOR STATE 0000 Tu 11:55:28 M19 N42121Z1 DETECTOR STATE 1111 Vehicle 2 Tu 11:55:29 M19 N42121Z1 DETECTOR STATE 1111 Tu 11:55:30 M19 N42121Z1 DETECTOR STATE 1011 Vehicle 3 Tu 11:55:31 M19 N42121Z1 DETECTOR STATE 1111 Tu 11:55:32 M19 N42121Z1 DETECTOR STATE 1111 Tu 11:55:33 M19 N42121Z1 DETECTOR STATE 1111 Tu 11:55:34 M19 N42121Z1 DETECTOR STATE 1111 Tu 11:55:35 M19 N42121Z1 DETECTOR STATE 1111 Tu 11:55:36 M19 N42121Z1 DETECTOR STATE 1100 Tu 11:55:37 M19 N42121Z1 DETECTOR STATE 0011 Vehicle 4 Tu 11:55:38 M19 N42121Z1 DETECTOR STATE 1111 Tu 11:55:39 M19 N42121Z1 DETECTOR STATE 1000 Tu 11:55:40 M19 N42121Z1 DETECTOR STATE 0000 Tu 11:55:41 M19 N42121Z1 DETECTOR STATE 1111 Vehicle 5 Tu 11:55:42 M19 N42121Z1 DETECTOR STATE 0000 Tu 11:55:43 M19 N42121Z1 DETECTOR STATE 0000 A further example below shows the fourth vehicle delayed for considerably longer in the TrafiCam detection zone than over the loop. It appears that the fifth vehicle arrived some time after the fourth had started queuing in the TrafiCam detection zone and queued over the loop until the fourth vehicle started to move. TRL 10 PPR434

19 SCOOT We 10:37:19 M19 N42121B1 DETECTOR STATE 0000 We 10:37:20 M19 N42121B1 DETECTOR STATE 0001 Vehicle 1 We 10:37:21 M19 N42121B1 DETECTOR STATE 1100 We 10:37:22 M19 N42121B1 DETECTOR STATE 0011 Vehicle 2 We 10:37:23 M19 N42121B1 DETECTOR STATE 1110 We 10:37:24 M19 N42121B1 DETECTOR STATE 0000 We 10:37:25 M19 N42121B1 DETECTOR STATE 0011 Vehicle 3 We 10:37:26 M19 N42121B1 DETECTOR STATE 1111 We 10:37:27 M19 N42121B1 DETECTOR STATE 0011 Vehicle 4 We 10:37:28 M19 N42121B1 DETECTOR STATE 1111 We 10:37:29 M19 N42121B1 DETECTOR STATE 1100 We 10:37:30 M19 N42121B1 DETECTOR STATE 0000 We 10:37:31 M19 N42121B1 DETECTOR STATE 0000 We 10:37:32 M19 N42121B1 DETECTOR STATE 0000 We 10:37:33 M19 N42121B1 DETECTOR STATE 0011 Vehicle 5 We 10:37:34 M19 N42121B1 DETECTOR STATE 1111 We 10:37:35 M19 N42121B1 DETECTOR STATE 1111 We 10:37:36 M19 N42121B1 DETECTOR STATE 1111 We 10:37:37 M19 N42121B1 DETECTOR STATE 0000 We 10:37:38 M19 N42121B1 DETECTOR STATE 0000 We 10:37:39 M19 N42121B1 DETECTOR STATE 0000 We 10:37:40 M19 N42121B1 DETECTOR STATE 0000 We 10:37:41 M19 N42121B1 DETECTOR STATE 0011 Vehicle 6 We 10:37:42 M19 N42121B1 DETECTOR STATE 1111 We 10:37:43 M19 N42121B1 DETECTOR STATE 0000 TrafiCam We 10:37:20 M19 N42121Z1 DETECTOR STATE 0000 We 10:37:21 M19 N42121Z1 DETECTOR STATE 0111 Vehicle 1 We 10:37:22 M19 N42121Z1 DETECTOR STATE 1000 We 10:37:23 M19 N42121Z1 DETECTOR STATE 0111 Vehicle 2 We 10:37:24 M19 N42121Z1 DETECTOR STATE 1110 We 10:37:25 M19 N42121Z1 DETECTOR STATE 0000 We 10:37:26 M19 N42121Z1 DETECTOR STATE 0001 Vehicle 3 We 10:37:27 M19 N42121Z1 DETECTOR STATE 1111 We 10:37:28 M19 N42121Z1 DETECTOR STATE 1011 Vehicle 4 We 10:37:29 M19 N42121Z1 DETECTOR STATE 1111 We 10:37:30 M19 N42121Z1 DETECTOR STATE 1111 We 10:37:31 M19 N42121Z1 DETECTOR STATE 1111 We 10:37:32 M19 N42121Z1 DETECTOR STATE 1111 We 10:37:33 M19 N42121Z1 DETECTOR STATE 1111 We 10:37:34 M19 N42121Z1 DETECTOR STATE 1111 We 10:37:35 M19 N42121Z1 DETECTOR STATE 1111 We 10:37:36 M19 N42121Z1 DETECTOR STATE 1111 We 10:37:37 M19 N42121Z1 DETECTOR STATE 1000 We 10:37:38 M19 N42121Z1 DETECTOR STATE 0001 Vehicle 5 We 10:37:39 M19 N42121Z1 DETECTOR STATE 1111 We 10:37:40 M19 N42121Z1 DETECTOR STATE 1110 We 10:37:41 M19 N42121Z1 DETECTOR STATE 0000 We 10:37:42 M19 N42121Z1 DETECTOR STATE 0011 Vehicle 6 We 10:37:43 M19 N42121Z1 DETECTOR STATE 1110 We 10:37:44 M19 N42121Z1 DETECTOR STATE 0000 Other examples of the loop not staying on for longer than 3.5 seconds are not clear with a vehicle being detected for much longer by the TrafiCam than by the loop, but detected by both for part of the time. There may then be an appreciable gap on the loop, but that TRL 11 PPR434

20 could be that the original vehicle has moved forward off the loop, but still detected by the TrafiCam and it is the last vehicle in the queue. In some cases the loop recorded two vehicles with a gap between them of a second or so, but the TrafiCam only recorded one vehicle, but for a long time; subsequent vehicles were detected by both the loop and TrafiCam. TRL 12 PPR434

21 5 Conclusions The overall agreement between the TrafiCam and the inductive loop was good. The TrafiCam detection system tested for SCOOT seemed to work well in comparison with a loop system. Because of the need for the TrafiCam to see the rear lights of vehicles, its detection zone was not coincident with the inductive loop. Therefore, comparison of individual vehicle counts in slow moving traffic was more difficult than it would have been with coincident detection zones. Nevertheless, 99% of individual vehicle detections were matched. Total occupancy recorded by the TrafiCam was about 10% greater than the loop. Some of this difference could have been due to a slightly longer effective detection zone. In addition, the TrafiCam detection zone was downstream of the loop and, therefore, more likely to be queued in, resulting in more vehicles being delayed in its detection zone, hence greater occupancy, than over the loop. The SCOOT validation process would allow for a small difference in the length of the detection zone, which would then have no practical effect on the operation of SCOOT. There were some differences in the outputs of the two detectors when traffic was queuing back to the detector zones. Some of the differences could be explained in terms of the difference in detection zones, but in a very few cases it appeared that the TrafiCam might have stuck on for some time (up to half a minute) during which the loop detected several vehicles. Acknowledgements The work described in this report was carried out in the Traffic Group of the Transport Research Laboratory. The author is grateful to I J Burrow who carried out the technical review and auditing of this report. The research would not have been possible without the cooperation of Hampshire County Council and the author would like to acknowledge Adrian Gray for authorising the use of Hampshire facilities and Roger Derrick for his technical assistance and data collection. TRL 13 PPR434

22

23

24 Test of TrafiCam vehicle detector in Winchester A Traficam video vehicle detector was installed adjacent to a standard SCOOT inductive loop detector in Winchester. Outputs from the two detectors were returned to SCOOT and recorded for analysis. The inductive loop output was used in the SCOOT control algorithms as normal, but the trial Traficam detector was ignored by them. The status of both detectors, off or on, each quarter second was output in standard SCOOT messages and compared. The comparison was complicated as it was necessary to define the Traficam detection zone slightly downstream of that of the loop, but it was possible to make valid comparisons. Other titles from this subject area PPR206 International comparison of roundabout design guidelines. J Kennedy PPR240 Behaviour at cycle Advanced Stop Lines. D Allen, S Bygrave and H Harper PPR252 PPR275 Survey of MOVA and SCOOT operation at M42 Junction 6. K Wood, M Crabtree, A Kirkham, A Maxwell and R Robbins Development of a human factors road safety assessment tool: interim report. D Basacik, T Luke and T Horberry PPR292 A review of simplified Streetscape Schemes. A Quimby and J Castle PPR298 The travel of errant vehicles after leaving the carriageway. D A Lynam and J V Kennedy Price code: 2X ISSN TRL Crowthorne House, Nine Mile Ride Wokingham, Berkshire RG40 3GA United Kingdom T: +44 (0) F: +44 (0) E: enquiries@trl.co.uk W: Published by IHS Willoughby Road, Bracknell Berkshire RG12 8FB United Kingdom T: +44 (0) F: +44 (0) E: trl@ihs.com W: PPR434

REMOTE AUTOMATIC INCIDENT DETECTION USING INDUCTIVE LOOP DETECTORS

REMOTE AUTOMATIC INCIDENT DETECTION USING INDUCTIVE LOOP DETECTORS REMOTE AUTOMATIC INCIDENT DETECTION USING INDUCTIVE LOOP DETECTORS Tom Cherrett, (BSc, PhD, MCILT) Lecturer, Transportation Research Group tjc3@soton.ac.uk Ben Waterson (BSc, MSc) Lecturer, Transportation

More information

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections. ISSUES ISSUE DATE RELEASED DETAILS OF CHANGE AUTHOR 4 Rev 2 September 2004 Changes for 4000 series. DB 4 Rev 3 April 2005 Screen shots updated and other minor changes K.Z. 4 Rev 4 September 2006 4 Rev

More information

The use of simulation in the design of a road transport incident detection algorithm

The use of simulation in the design of a road transport incident detection algorithm The use of simulation in the design of a road transport incident detection algorithm Ben J. Waterson (BSc, MSc) Lecturer, Transportation Research Group B.J.Waterson@soton.ac.uk Tom J. Cherrett (BSc, PhD,

More information

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND +44 (0) 1282 717171 www.protec.co.uk

More information

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS Below you will find information about your installation and what you can expect to happen next. There are also some important steps to follow to ensure

More information

AUTOMATIC FIRE DETECTION AND ALARM SYSTEMS

AUTOMATIC FIRE DETECTION AND ALARM SYSTEMS AUTOMATIC FIRE DETECTION AND ALARM SYSTEMS An excellent overview of automatic fire detection and alarm systems used in commercial and industrial buildings how they are designed, how you can manage them,

More information

Wayside horn noise investigation

Wayside horn noise investigation Wayside horn noise investigation Simon Moore AECOM, Level 28, 91 King William Road, Adelaide, Australia ABSTRACT Warning horns are used by trains and sounded when approaching a level to warn of its presence.

More information

SH 242 ADAPTIVE TRAFFIC SIGNAL SYSTEM DEPLOYMENT

SH 242 ADAPTIVE TRAFFIC SIGNAL SYSTEM DEPLOYMENT October 13, 2015 SH 242 ADAPTIVE TRAFFIC SIGNAL SYSTEM DEPLOYMENT TxDOT Houston Steve Chiu TxDOT Manu Isaac Kimley-Horn The Corridor SH 242 North of Houston Near Woodlands Six Signals west of IH 45 (St

More information

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL 6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0)

More information

[ [ ADMIN PANEL USER GUIDE

[ [ ADMIN PANEL USER GUIDE [ [ ADMIN PANEL USER GUIDE ADMIN PANEL USER GUIDE 2 Contents Logging In & Systems Overview 3 System Details 5 Analytics 6 View Alarms 8 Manage Alarms 9 Create Alarms 10 Device Reporting Alarm 11 Monthly

More information

Integration Test Plan

Integration Test Plan Integration Test Plan Terminus Security Prepared by: Kai Chan Stephen Krenzel John O Meara Version: 1.0 1 Contents 1 Introduction 3 1.1 Purpose.................................. 3 1.2 Scope...................................

More information

NON-INTRUSIVE DETECTION, THE WAY FORWARD

NON-INTRUSIVE DETECTION, THE WAY FORWARD NON-INTRUSIVE DETECTION, THE WAY FORWARD P Beyer Syntell (PTY) LTD, 64-74 White Road, Retreat, 7945 Office: +27 (0) 21 710 2764 Email: patrickb@syntell.co.za ABSTRACT With an increasing demand on our transportation

More information

smart modules An integrated and customised video analytics solution for the real-time events detection

smart modules An integrated and customised video analytics solution for the real-time events detection smart modules An integrated and customised video analytics solution for the real-time events detection www.aitek.it Video-analytics software platform AiVu-Smart Modules is a modular video analytics solution

More information

METHOD STATEMENT. Process. Document Authorisation Role Name Function Signed Prepared by:

METHOD STATEMENT. Process. Document Authorisation Role Name Function Signed Prepared by: METHOD STATEMENT Process Process for: The installation of a WiMag Detector. Document Authorisation Role Name Function Signed Prepared by: A. Kendrick Project Support Engineer Reviewed by: Colin Whipps

More information

Guidance on Video Smoke Detection Technology (VSD)

Guidance on Video Smoke Detection Technology (VSD) Guidance Note Guidance on Video Smoke Detection Technology (VSD) Guidance on Video Smoke Detection Technology (VSD) SCOPE... 3 INTRODUCTION... 4 WHAT IS VSD?... 5 STANDARDS... 7 GENERAL GUIDANCE ON THE

More information

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we appreciate your taking the time to learn more about this

More information

Victor Shapilsky and Adison Ang

Victor Shapilsky and Adison Ang Victor Shapilsky and Adison Ang Incident Detection Systems in Motorway Tunnels Overview Incidents Delayed incident detection Performance criteria for incident detection systems Available incident detection

More information

False Alarm Management

False Alarm Management False Alarm Management This document is intended only for fire system professionals who are already experienced in the selection and positioning of fire detectors. Whenever you apply any False Alarm Management

More information

How Computer Simulation Helps to Design Induction Heating Systems

How Computer Simulation Helps to Design Induction Heating Systems Large Pipe Powder Coating Page 1 ASM 2001 How Computer Simulation Helps to Design Induction Heating Systems Dr. Valentin S. Nemkov, Chief Scientist Mr. Robert C. Goldstein, Research Engineer Mr. Robert

More information

Assessment of the variable speed limits. Ruben Corthout Chris M.J. Tampère

Assessment of the variable speed limits. Ruben Corthout Chris M.J. Tampère Assessment of the variable speed limits around Antwerp Ruben Corthout Chris M.J. Tampère Overview of presentation Introduction and scope Assessment from the drivers perspective Case study Antwerp Ex-ante

More information

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings Fire Science and Technorogy Vol.24 No.4(2005) 165-178 165 Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings Jun-ichi Yamaguchi 1, Takeyoshi Tanaka 2 1 Technical Research

More information

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010 Procidia iware AlarmWorX32 AlarmWorX32 Viewer Siemens Protection AG 2008. notice All / Copyright rights reserved. notice Introduction / Contents Procidia iware is an operator interface software designed

More information

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME Elizabeth L. Milarcik, Stephen M. Olenick*, and Richard J. Roby Combustion Science & Engineering,

More information

Datalogging as standard

Datalogging as standard Datalogging as standard for expanded performance Autofim II and Autofim II GC have a sophisticated datalogging system, as standard, which enables you to keep a permanent data record. The memory is capable

More information

Security Management System - Configuring Video Analytics

Security Management System - Configuring Video Analytics Introduction This document describes the steps for configuring the Video Analytics (VA) module available in the Security Management System software. Security Management System video analytics module is

More information

Statement of Community Involvement LAND OFF SOUTHDOWN ROAD HORNDEAN, HAMPSHIRE

Statement of Community Involvement LAND OFF SOUTHDOWN ROAD HORNDEAN, HAMPSHIRE LAND OFF SOUTHDOWN ROAD HORNDEAN, HAMPSHIRE CONTENTS Page 1. Introduction 3 2. Pre-application Discussions 4 3. The Consultation Process 5 4. Consultation Feedback 7 5. Responses to Consultation Feedback

More information

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach EEDAL 2009 16-18 June 2009 Reducing the Footprint of Existing Domestic Heating: A Non-Disruptive Approach Martin O Hara Danfoss Randall Limited Abstract There is insufficient time between today and 2020

More information

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL 3500 CONVENTIONAL FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web:

More information

Gallagher System Integrations

Gallagher System Integrations Gallagher System Integrations Gallagher Command Centre supports integrations with a range of third party security products, using Gallagher developed interface software and industry standard protocols.

More information

SMARTWALK DEMENTIA WANDERING SYSTEM

SMARTWALK DEMENTIA WANDERING SYSTEM A division of NESS CORPORATION PTY LTD SMARTWALK DEMENTIA WANDERING SYSTEM SWD Door Responder SWD Resonator SWD-PET (Sold Separately) SWD-PET-BAND (Sold Separately) INSTALLATION MANUAL 1. CONTENTS 1. CONTENTS...1

More information

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification LMV52 Control Product Description February 3, 2017 The LMV52 is a microprocessor-based burner management system with matching system components for the control and supervision of forced draft burners.

More information

Improved Dryer Control

Improved Dryer Control Improved Dryer Control Kenneth C. Hill President Kadant Johnson Systems Division David Vijh Senior Process Control Engineer Technical White Paper Series EXECUTIVE SUMMARY Significant improvements in dryer

More information

WHAT HAPPENS NEXT for ADT Interactive Security Customers

WHAT HAPPENS NEXT for ADT Interactive Security Customers WHAT HAPPENS NEXT for ADT Interactive Security Customers Interactive Security Below you will find information about your installation and what you can expect to happen next. There are also some important

More information

How to use the BTRM in Remote Enclosures

How to use the BTRM in Remote Enclosures How to use the BTRM in Remote Enclosures Part Number: BTRM-200 Product Release Date: April 01, 2013 Software version: BTRM2_2013-05-06_2316_DNPV2V130D The Ventev Battery Test Remote Monitor (BTRM) has

More information

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification SCC Inc. LMV51 Control Product Description February 7, 2017 The LMV51 is a microprocessor-based burner management system with matching system components for the control and supervision of forced draft

More information

Loop Detectors for Motorways

Loop Detectors for Motorways Loop Detectors for Motorways DN-ITS-03020 October 2013 DN Design Standards TRANSPORT INFRASTRUCTURE IRELAND (TII) PUBLICATIONS About TII Transport Infrastructure Ireland (TII) is responsible for managing

More information

intrinsically safe detector for hydrocarbon gases

intrinsically safe detector for hydrocarbon gases portable flame ionisation detector intrinsically safe detector for hydrocarbon gases Intrinsically safe detector for hydrocarbon gases Monitoring gases in confined and potentially explosive situations

More information

Groupe de sécurité Gunnebo 28 mars 2017 page 1. SoloTek

Groupe de sécurité Gunnebo 28 mars 2017 page 1. SoloTek Groupe de sécurité Gunnebo 28 mars 2017 page 1 SoloTek Summary Single-passage Detector Snaptshot of risks and needs Role in security procedures SoloTek system Cycle stages Dealing with SoloTek Benefits

More information

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

ZERIO PLUS EDA-Z5008, Z5020 & Z5100 ZERIO PLUS EDA-Z5008, Z5020 & Z5100 USER MANUAL Revision 1.00 EDA-Z5008, Z5020 & Z5100 User Manual 0359 Electro Detectors Limited Electro House Edinburgh Way Harlow, Essex CM20 2EG, UK 14 0359 CPR 00226

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide CM707 Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start User Guide WHAT IS A PROGRAMMABLE ROOM THERMOSTAT? An explanation for householders... A programmable room thermostat

More information

EVALUATION OF SENSYS WIRELESS DETECTION SYSTEM: YEAR-AFTER EVALUATION AND OFF-CENTER SENSORS

EVALUATION OF SENSYS WIRELESS DETECTION SYSTEM: YEAR-AFTER EVALUATION AND OFF-CENTER SENSORS CIVIL ENGINEERING STUDIES Illinois Center for Transportation Series No. 11-083 UILU-ENG-2011-2009 ISSN: 0197-9191 EVALUATION OF SENSYS WIRELESS DETECTION SYSTEM: YEAR-AFTER EVALUATION AND OFF-CENTER SENSORS

More information

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols) Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.) BETTER TO BE SAFE Discovery Analogue Addressable Fire Alarm Panels Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA

More information

Section 9 System Operation

Section 9 System Operation Section 9 System Operation Operation of the control panel is simple. Menus guide you step-by-step through operations. This section of the manual is an overview of the operation menus. Please read this

More information

Statistical Analysis of Criteria and Key Aspects for Urban Design Quality Assessment of Built Environment

Statistical Analysis of Criteria and Key Aspects for Urban Design Quality Assessment of Built Environment Statistical Analysis of Criteria and Key Aspects for Urban Design Quality Assessment of Built Environment Ar. Mohd. Khalid Hasan 1 *, Prof. S. K. Gupta 2, Dr. (Mrs) Sangeeta Bagga Mehta 3 1 Assistant Professor,

More information

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System World Class Leaders in Fire Detection Since 1918 FIREscape+ RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System GLOBALLY PROVEN PRODUCT DESIGN The F REscape+ system is the first of its

More information

Sales FAQ. Paradox Insight - General. 1. What is Paradox Insight?

Sales FAQ. Paradox Insight - General. 1. What is Paradox Insight? Sales FAQ We ve compiled a list of frequently asked questions regarding Paradox Insight solution to assist you in the marketing and sales of your Paradox Insight solution. If you have a question that does

More information

ID50series. intelligent fire alarm panels

ID50series. intelligent fire alarm panels ID50series intelligent fire alarm panels features LPCB approved to EN54 parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports NOTIFIER advanced range of

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Cardax System Comparison

Cardax System Comparison System Comparison Hardware FT Series 5 Syst Com 131102 Syst Com 131102 2 Contents 1. Introduction... 5 2. System Diagrams... 7 3. Hardware Comparison... 10 4. Comparison... 11 Syst Com 131102 3 Syst Com

More information

Low Cost Vehicle Detection System to Help Green UCI Parking

Low Cost Vehicle Detection System to Help Green UCI Parking Low Cost Vehicle Detection System to Help Green UCI Parking Presented by: University of California, Irvine s ITE Student Chapter May 25, 2011 Presenters: Benjamin Fuller (President) Jonathan Masukawa (Vice

More information

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline Dr Jun Zhang & Dr Ling Xu* REL Instrumentation Limited ABSTRACT In the past ten years, a number of pipeline leak detection systems

More information

VMD Guide for MP-980 Cameras

VMD Guide for MP-980 Cameras Configuration Guide XX206-10-01 VMD Guide for MP-980 Cameras Vicon Industries Inc., 89 Arkay Drive, Hauppauge, New York 11788 Tel: 631-952-2288 Fax: 631-951-2288 Toll Free: 800-645-9116 24-Hour Technical

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

Architectural and Engineering Specification for a Real-Time Locating System Flare

Architectural and Engineering Specification for a Real-Time Locating System Flare Architectural and Engineering Specification for a Flare AE-T1-IN-R3-E-0617 Page 1 of 14 This document is intended to provide performance specifications and operational requirements for the Flare. It is

More information

Ultrasonic Clamp-On Flow Meter Testing

Ultrasonic Clamp-On Flow Meter Testing Ultrasonic Clamp-On Meter Testing Carried out for Micronics Ltd By Colin Judd Ultrasonic Clamp-On Meter Testing Carried out for: Micronics Ltd Unit B4 Business Centre Davies Way Loudwater High Wycombe

More information

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure.

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure. A new view on building protection Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure. Safety made easier. As an easy-to-use system with a single point

More information

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection A Cost Effective Multi-Spectral Scanner for Natural Gas Detection Semi-Annual Progress Report No. 1 Reporting Period Start Date: October 1, 2003 Reporting Period End Date: March 31, 2004 Principal Authors:

More information

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast August, 2006 Sensor Electronics Corporation 5500 Lincoln Drive USA (952) 938-9486 Table Of Contents: Intended Audience... 3 Purpose...3 Overview...

More information

Fire Performance of external thermal insulation for walls of multistorey buildings

Fire Performance of external thermal insulation for walls of multistorey buildings Fire Performance of external thermal insulation for walls of multistorey buildings third edition Sarah Colwell and Tony Baker fire performance of external thermal insulation for walls of multistorey buildings

More information

LaserFOCUS VLF-250 Engineering Specification

LaserFOCUS VLF-250 Engineering Specification Vision Fire & Security LaserFOCUS VLF-250 Engineering Specification May 2004 Part Number 20296 LaserFOCUS VESDA 2 VESDA LaserFOCUS Contents Scope...4 Description...4 General...4 Approvals...4 Codes, Standards

More information

TELECOMMUNICATION EQUIPMENT LOCATED IN THE VICINITY OF PROPOSED DISTRIBUTION HV EARTHS

TELECOMMUNICATION EQUIPMENT LOCATED IN THE VICINITY OF PROPOSED DISTRIBUTION HV EARTHS Network Asset Technical Document TELECOMMUNICATION EQUIPMENT LOCATED IN THE VICINITY OF PROPOSED DISTRIBUTION HV EARTHS Original Issue: August 2006 Prepared by: M. Lamparski This Revision: Rev 1 October

More information

1 Introduction - The rating level. 3 Subjective or objective analysis? 2 Determination of the adjustment for annoying tones

1 Introduction - The rating level. 3 Subjective or objective analysis? 2 Determination of the adjustment for annoying tones Noise can be said to be tonal if it contains a distinguishable, discrete, continuous note. This may include a whine, hiss, screech, hum, etc., and any such subjective finding is open to discussion when

More information

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL Fire Alarm Control Panel & MANUAL CONTENTS SECTION -. Description of the fire control panel fascia.... Alarm.... Reset the system.... Sound and silence the alarms.... Read the Fire, Fault, Test and Disabled

More information

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

For assistance with the product please contact: HELPLINE. For a product brochure please contact: For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2

More information

Installation Guide Bacharach Communications Adapter HGM-MZ to Johnson Controls Metasys N2 Network (Electrically Isolated N2 Port Version)

Installation Guide Bacharach Communications Adapter HGM-MZ to Johnson Controls Metasys N2 Network (Electrically Isolated N2 Port Version) Installation Guide Bacharach Communications Adapter HGM-MZ to Johnson Controls Metasys N2 Network (Electrically Isolated N2 Port Version) 621 Hunt Valley Circle New Kensington, PA 15068 Tel: 724-334-5000

More information

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

For assistance with the product please contact: HELPLINE. For a product brochure please contact: For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2

More information

From induction loops to radar technology: The right detector system for any application siemens.com/mobility

From induction loops to radar technology: The right detector system for any application siemens.com/mobility Siemens Traffic Detectors From induction loops to radar : The right detector system for any application siemens.com/mobility Eight technologies, one outcome: Optimum data input for perfect traffic control

More information

Grower Summary PO 005

Grower Summary PO 005 Grower Summary PO 005 Column stocks (cut-flowers): An Investigation into the cause(s) of poor establishment, growth and flower uniformity in commercial crops. Annual 2011 Disclaimer AHDB, operating through

More information

Linden Homes Proposals for Havant Retail Park, Portsdown Hill Road, Bedhampton. Welcome

Linden Homes Proposals for Havant Retail Park, Portsdown Hill Road, Bedhampton. Welcome Welcome Welcome to Linden Homes public exhibition in connection with its proposals for a range of high quality new open market, affordable homes and open space on the site of the Havant Retail Park. Today

More information

Remote Monitoring of Offshore Structures using Acoustic Emission.

Remote Monitoring of Offshore Structures using Acoustic Emission. 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Remote Monitoring of Offshore Structures using Acoustic Emission. More Info at Open Access Database

More information

Tebis application software

Tebis application software 5 Tebis application software STCC530E 2-channel presence detector 360 A faire Product reference Description TP device RF devices TCC530E Bi-zone presence detector TCC530E Output module: Dimmer Loads connected

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

Electromagnetic Compatibility of Alarm Systems

Electromagnetic Compatibility of Alarm Systems Electromagnetic Compatibility of Alarm Systems Jan VALOUCH Tomas Bata University in Zlin, Faculty of Applied Informatics, Nad Stráněmi 4511, 76005, Zlín, Czech Republic valouch@fai.utb.cz. Abstract. Alarm

More information

Different types of Fire Alarm System

Different types of Fire Alarm System Different types of Fire Alarm System Conventional Fire System Generally comes with Zones. Each zone can have max 20 detectors. Addressable Fire Alarm System This comes in loops. Different manufacturer

More information

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION DET-TRONICS SPECIFICATION DATA Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION The EQ2200UVHT UV Flame Detector is used with the Eagle Quantum

More information

ARCHITECTURAL SPECIFICATIONS

ARCHITECTURAL SPECIFICATIONS 1 G4.1 Entrance System Page 1 of 6, August 2017 DIVISION 10 - SPECIALTIES SECTION 10450 PEDESTRIAN CONTROL DEVICES Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements.

More information

I/A Series Software. Differential Gap (DGAP) Controller Block PSS 21S-3C5 B4 OVERVIEW PRODUCT SPECIFICATIONS

I/A Series Software. Differential Gap (DGAP) Controller Block PSS 21S-3C5 B4 OVERVIEW PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS I/A Series Software Differential Gap (DGAP) Controller Block The DGAP Controller block is a differential gap on-off controller for controlling bi-state or tri-state control applications.

More information

Comfort Applications Manual

Comfort Applications Manual Comfort Applications Manual Comfort This page intentionally left blank. Security/Automation Integration SECURITY / AUTOMATION INTEGRATION. Automatically Switch off appliances when system is armed. Programming

More information

FS Mircom FX2000 Fire Alarm Panel

FS Mircom FX2000 Fire Alarm Panel Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8705-16 Mircom FX2000 Fire Alarm Panel APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after May 1, 2001 Chipkin Automation

More information

Connections, displays and operating elements C D E G H. Installing the control unit

Connections, displays and operating elements C D E G H. Installing the control unit 1 2 3 GB Control unit 0-10 V REG-K/3-gang with manual mode Operating instructions Art. no. MTN646991 ¼ DANGER Risk of fatal injury from electrical current. All work on the device should only be carried

More information

BUILDING MANAGEMENT SYSTEMS. Introduction to Building Management Systems

BUILDING MANAGEMENT SYSTEMS. Introduction to Building Management Systems BUILDING MANAGEMENT SYSTEMS Introduction to Building Management Systems The Building Management System is used for all the functions carried out by the building including energy services security monitoring,

More information

FALSE ALARM ACTIVITY IN THE U.S. 2012

FALSE ALARM ACTIVITY IN THE U.S. 2012 FALSE ALARM ACTIVITY IN THE U.S. 2012 Michael J. Karter, Jr. December 2013 National Fire Protection Association Fire Analysis and Research Division Abstract In 2012, U.S. fire departments responded to

More information

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B Dear Customer Please find enclosed Amendment 4, effective 14 February 2014, to the Acceptable Solution and Verification Method for Clause F8 Signs of the New Zealand Building Code. THe previous amendment

More information

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming. SECTION 260943 SPECIFICATIONS - Wireless Network Lighting Controls. PART 1 - GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY AND KEY SYSTEM DIFFERENTIATORS A. The lighting control system specified herein shall

More information

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441 J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441 Response-Time Comparisons of Ionization and Photoelectric/Heat Detectors 1. Introduction Despite

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

Substation Monitoring System

Substation Monitoring System Substation Monitoring System UHF Partial Discharge Monitoring System Description Introduction The UHF PDM System is the third generation, spanning 20 years, of monitoring systems developed for GIS partial

More information

Re: ENSC440 Functional Specification for a License Plate Recognition Auto-gate System

Re: ENSC440 Functional Specification for a License Plate Recognition Auto-gate System February 16 th, 2009 Mr. Patrick Leung School of Engineering Science Simon Fraser University 8888 University Drive Burnaby BC V5A 1S6 Re: ENSC440 Functional Specification for a License Plate Recognition

More information

FlameGard 5 MSIR HART

FlameGard 5 MSIR HART FlameGard 5 MSIR HART Multi-Spectral Infrared Flame Detector HART Communication with the FlameGard 5 Multi-spectral Infrared Detector The information and technical data disclosed in this document may be

More information

USER S GUIDE. AXIS Cross Line Detection

USER S GUIDE. AXIS Cross Line Detection USER S GUIDE AXIS Cross Line Detection User s Guide Rev. 1.00 Copyright Axis Communications AB, 2009 November 2009 Part no. 36687 AXIS Cross Line Detection AXIS Cross Line Detection is a trip-wire application

More information

TECHNICAL BULLETIN No: 0040

TECHNICAL BULLETIN No: 0040 National Security Inspectorate Sentinel House, 5 Reform Road, Maidenhead, SL6 8BY E: nsi@nsi.org.uk W: nsi.org.uk Dated: 12 October 2017 To: 1. All NSI NACOSS Gold and System Silver Companies 2. Applicant

More information

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax: Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: 01730 268 231. Fax: 01730 265 552 Scimitar user manual & log book SCIMITAR USER MANUAL Approved Document No. DFU7001001 Rev 2

More information

intelligent fire alarm ID60series panels

intelligent fire alarm ID60series panels intelligent fire alarm ID60series panels features LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Procedure for the Approval of New Fire Detection and Alarm Technologies

Procedure for the Approval of New Fire Detection and Alarm Technologies VdS Guidelines for Automatic Fire Detection and Fire Alarm Systems VdS 3469en Procedure for the Approval of New Fire Detection and Alarm Technologies VdS 3469en : 2016-01 (01) Publisher and publishing

More information

1 Opening the IPS WebViewer Activating or Deactivating the Detection Selecting a Profile Text Overlays...

1 Opening the IPS WebViewer Activating or Deactivating the Detection Selecting a Profile Text Overlays... Operating Instruction IPS Video Analytics for Axis ACAP Cameras and Encoders Contents 1 Opening the IPS WebViewer... 1 2 Activating or Deactivating the Detection... 3 3 Selecting a Profile... 3 4 Text

More information

Generic Specifications for Incident Detection Systems

Generic Specifications for Incident Detection Systems RAIDER Generic Specifications for Incident Detection Systems Draft Deliverable 4.1 June 2013 Project Coordinator TNO TRL AIT FEHRL This project was initiated by ERA-NET ROAD. Project Nr. 832568 Project

More information

Automatic Fire Alarm Service Provider Computer Interface Specification for Extended Alarm Protocol (XAP) Devices

Automatic Fire Alarm Service Provider Computer Interface Specification for Extended Alarm Protocol (XAP) Devices July 2017 Version 1.6 Automatic Fire Alarm Service Provider Computer Interface Specification for Extended Alarm Protocol (XAP) Devices For Fire and Emergency New Zealand December 2013 Table of contents

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information