1 DTS Light fittings for explosive atmospheres For all zones and industrial applications
2 LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light fittings XFFL Range - XFF Range - Fluorescent Tubular glass light fitting for Zones 1, 2, 21 & 22 All components mounted on sliding gear tray for easy installation and maintenance Available in glass for chemical environment and corrosive atmospheres Including accessories (cable gland, plug & fixing brackets) Supplied with offshore grade paint II 2 G, Ex d IIB or IIC T6 Gb for -20 C to +55 C XFP Range - Fluorescent with automatic switch off II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C Vac 50/60Hz IEC 62262: IK08 - module with diffuser II 2 G, Ex d IIB or IIC T6 Gb for -20 C to +55 C XEL Range - Self contained & Slave II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C Vac 50/60Hz Vdc Battery 3h - XFF EM ( Vac/Vdc 50/60Hz) IEC 62262: IK08 II 2 G, Ex de IIB or IIC T6 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C 2x18W, Vac 50/60Hz 110Vdc Battery 3h - XFP EM ( Vac/Vdc 50/60Hz) IEC 62262: IK08 II2G, Ex d IIC T6 Gb or II2G, Ex de IIC T6 Gb II 2 D, Ex tb IIIC T80 C Db & 1x4W Vdc 50-60Hz Battery 1h or 3h IEC62262 : IK07 Weatherproof polycarbonate tubular light fitting for industrial application FFL Range - FF Range - Fluorescent Ingress protection IP66 ideal for wash down areas All components mounted on a removable gear tray which gives easy access for installation & maintenance Tubular shape to avoid waste accumulation Including accessories (cable gland & fixing brackets) Possibility to retro-fit gear tray into existing fixtures mounted with T8 lamps. IP66, -20 C to +55 C Vac 50-60Hz IEC 62262: IK09 - module with diffuser IP66, -20 C to +55 C Vac 50-60Hz Battery 3h - self test - FF EMB IEC 62262: IK09
3 PRODUCT OVERVIEW - LIGHT FITTINGS FOR ALL ZONES AND INDUSTRIAL APPLICATIONS Light fittings for all zones and industrial applications Floodlights, warnings & wellglass XLF Range - XSF / XQF / XEF Range Floodlight fitting for Zones 1, 2, 21 & 22 & Industrial applications Integrated junction box Flat or pole mounting Including cable gland Supplied with offshore grade paint II 2 G, Ex de IIB T6 Gb for -20 C to +40 C or Ex de IIB T5 Gb for -20 C to +55 C or Ex de IIB T4 Gb for -20 C to +60 C II 2 D, Ex tb IIIC T85 C Db IP66 for -20 C to +40 C or Ex tb IIIC T100 C Db IP66 for -20 C to +55 C or Ex tb IIIC T135 C Db IP66 for -20 C to +60 C 105W Vac (+/- 10%) 50/60Hz Operating life > 50,000h (according to ambient temperature) IEC 62262: IK09 More than 7800 lumens output with narrow & wide beam II 2 G, Ex de IIB T3 or T4 or T5 Gb for -20 C to +40 C, Ex de IIB T4 or T3 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T100 C or T135 C or T200 C Db IP66 for -20 C to +40 C, Ex tb IIIC T200 C or T135 C Db & HP Sodium: 150W, 250W, 400W Metal Halide: 250W, 400W Halogen: 2x70W 230Vac 50Hz Other Voltages: 220Vac 60Hz / 120Vac 60Hz Flat or pole mounting SF / QF / EF Range Industrial applications Wellglass for industrial application & zones 2 & 22 - Wellglass Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge lamp according to models EVH, EVX Range - Wellglass II 2 GD, Ex d IIC T5 to T3 Gb, Ex tb IIIC T95 C to T164 C & HP Sodium: 70W, 150W, 250W, 400W Metal Halide: 150W, 250W, 400W Halogen: 70W, 140W, 250W 230Vac 50Hz Four 3/4 NPT entries - fitted with 2 plugs IP66, -20 C to +55 C HP Sodium: 150W, 250W, 400W Metal Halide: 250W, 400W Halogen: 2x70W 230Vac 50Hz Other Voltages: 220Vac 60Hz / 120Vac 60Hz Flat or pole mounting
4 LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Linear light fittings EVS Range - Fluorescent EVNL Range - Linear light fitting for all zones & Industrial applications Double central locking for ingress protection Automatic switch off upon opening for safe maintenance All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable gland & fixing brackets) II 2 G, Ex de IIC T4 Gb for -40 C to +60 C or Ex de IIC T5 Gb for -40 C to +35 C II 2 D, Ex tb IIIC T85 C Db & IP66 for -40 C to +60 C EVN Range - Fluorescent 108 to 254V ac or dc Battery 3h - EVS EM Battery 3h with automatic test and blackstart capabilities - EVS EMA II 3 G, Ex na IIC T5 for -40 C to +25 C, T4 for -40 C to +60 C Gc II 3 D, Ex tc IIIC T65 C for -40 C to +35 C or T85 C for -40 C to +60 C Dc Zones 2 & 22 EVDL Range Vac 50-60Hz - module with diffuser II 3 G, Ex na IIC T4 Gc for -40 C to +40 C, Ex na IIC T3 Gc for -40 C to +60 C II 3 D, Ex tc IIIC T65 C Dc IP66 for -40 C to +40 C, Ex tc IIIC T85 C Dc & IP66 for -40 C to +60 C Zones 2 & Vac or dc Battery 3h - self test - EVN EMB II 2 D, Ex tb IIIC T85 C Db for -40 C to +60 C, Ex tb IIIC T65 C Db for -40 C to +35 C Zones 21 & Vac 50-60Hz - module with diffuser EVD Range - Fluorescent EVT Range - Fluorescent Industrial applications EVTL Range - Industrial applications II 2 D, Ex tb IIIC T85 C Db for -40 C to +60 C, Ex tb IIIC T65 C Db for -40 C to +35 C Zones 2, & Vac/Vdc 50-60Hz Battery 3h - self test - EVD EMB Vac or dc 50-60Hz Battery 3h - self test - EVT EMB Vac 50-60Hz - module with diffuser
5 PRODUCT OVERVIEW - LIGHT FITTINGS FOR ALL ZONES AND INDUSTRIAL APPLICATIONS Light fittings for all zones and industrial applications Recessed light fittings Recessed lighting fitting for zones 1 & 2 Steel housing and body powder paint coated 6mm clear toughened glass panel Including accessories (cable gland) ESB Range - Fluorescent II 2 G, Ex de IIC T4 Gb for -40 C to +60 C Zones 1 & 2 2x18W, Vac or dc 50/60Hz Battery 3h - ESB EM IEC 62262: IK08
6 LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES About ABB Value commitment Oil & gas application 02 XEL About DTS DTS is part of the ABB group and provides a complete range of explosion proof lighting and emergency lighting. Our DTS range covers all zones of potential explosion gas & dust atmospheres and is compliant with most stringent national, European and international regulations including IECEx and ATEX standards, making it possible to be used in a wide variety of industries across most of the world. Our value commitment DTS is committed to helping you meet the challenges of corrosion prevention with electrical solutions, services and systems that deliver value. DTS helps to make your life easier by the practicality of its designs by providing effective advice and by being responsive to your need. 02
7
8 Thomas & Betts Ltd. Br. Member of the ABB Group Office 724 6WA West Wing Dubai Airport Free Zone PO Box Dubai United Arab Emirates T +971 (0) F +971 (0) E enquiryme@tnb.com Thomas & Betts Saudi Arabia Member of the ABB Group Building 128 Dammam Industrial Area #2 PO Box 514 Al Khobar Saudi Arabia T +966 (0) F +966 (0) E enquiryme@tnb.com new.abb.com/low-voltage/hazardous YouTube Channel Copyright 2018 ABB. All rights reserved. Specifications subject to change without notice. 9AKK107045A2778 REV A
PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres
PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones
More informationINERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)
FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries
More information60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx
60W Flameproof LED Emergency Linear Fixture - 100-250V AC - (2) 30W LED Lamps - ATEX/IECEx Part #: ATEX-HALP-EMG-48-2L-LED-2X30W-R1-220V Page: 1 The Larson Electronics ATEX-HALP-EMG-48-2L-LED-2X30W-R1-220V
More information40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated
40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated Part #: HALD-24-1X40CPR-LED-V2 Page: 1 The Larson Electronics HALD-24-1X40CPR-LED-V2 Explosion Proof LED Fixture provides
More informationHDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.
HDL106 LED LUMINAIRES For Harsh & Hazardous Environments www.chalmit.com Quality, Reliability and Low Maintenance Our LED Product Range Chalmit has over a century s worth of experience in providing cutting
More informationSafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending
SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world for industrial
More informationIllumination unit For sight glass level indicator Model LGI
Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication
More informationARRAN LED LED FLOODLIGHT. Standard Specification. Features
ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More informationDräger Polytron 8700 IR Detection of flammable gases and vapors
Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationDräger Polytron 5720 IR Toxic Gas Detection
Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More informationEx LED light fittings
About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment
More informationDräger Polytron 5720 IR Detection of carbon dioxide
Dräger Polytron 5720 IR Detection of carbon dioxide The Dräger Polytron 5720 IR is a cost effective explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high
More information25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL
25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low
More informationSafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications
SafeSite LED Area Light - ATEX / IECEx for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 Features & Benefits 5 year warranty L70
More informationLED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light
LED NEW FB-SERIES LED NEW-SF FIXTURE LED Explosion-proof Platform Light LED Tri-proof Light LED Explosion-proof Highbay Light LED NEW-CF FIXTURE LED Highbay Light LED Explosion-proof Light LED Explosion-proof
More informationDräger Polytron 8720 IR Detection of carbon dioxide
Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance
More informationGRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S
www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More informationXLFE-4/1. Borosilicate glass globe
XLFE-4/1 Borosilicate glass globe - Zone 1, 2, 21, 22 - Obstruction warnings - LOW INTENSITY LED technology - Lamp lifespan more than 10 years - Complies with ICAO, FAA Painted aluminium body Ex e terminal
More informationTrusted worldwide since 1989 INTRINSICALLY SAFE RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting systems. Our main objective is to offer high
More informationHigh bay LED lighting fixture
Supporting bracket EWL - Zone 1, 2, 21, 22 - Replacing traditional discharge lamps of up to 750W - Savings in energy, maintenance and installation costs - Instant, brilliant illumination - Suitable for
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationCCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights
CCA-03EX - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22 Directional LED spotlights Body and lid in coated aluminium LED for proper operation monitoring 127 ED.2018
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance
More informationINTRINSICALLY SAFE LIGHTING RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE LIGHTING RANGE SAFE PORTABLE RECHARGEABLE AC MAINS Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting
More informationDräger Polytron 8700 IR Detection of flammable gases and vapors
Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationMultiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55
www.stahl.de > Pre-wi ready-to-use multi-signalling unit > Corrosion resistant > Suitable for offshore / onshore harsh environments > Incorporates the FX15 GRP beacon YA90 for visual audible notification
More informationJAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22
JAMIN 100 Compact impervious luminaire for ATEX zones Zones 2, 21, 22 JAMIN 100 ATEX LIGHTING THEY TRUST US: ACETEX CHIMIE, ADISSEO, ADNATCO (Abu Dhabi National Tanker Company), Airbus, BRITISH PETROLEUM,
More informationEVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation
EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED
More information208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC
208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC Part #: EPL-EMGX-LP-2X48-LED Page: 1 The Larson Electronics EPL-EMGX-LP-2X48-LED Low Profile Explosion Proof
More information25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC
25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame - 120-277V AC Part #: EXHL-TRN-LE1-1227 Page: 1 Made in Texas The EXHL-TRN-LE1-1227 from Larson Electronics is an Explosion
More informationLow Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E
Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer - 140 - C1D1 - C2D2 - ISO 14644/FS-209E Part #: HALD-24-1X150LED-V2-140DB Page: 1 Made in the USA The HALD-24-1X150LED-V2-140DB from Larson Electronics
More informationDräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors
Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger
More information26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE
26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE Part #: EPL-LP-12-LED Page: 1 The EPL-LP-12-LED from Larson Electronics is a Low Profile Explosion Proof
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationHubbell Harsh & Hazardous. Our Brands. Corporate Information
www.chalmit.com Hubbell Harsh & Hazardous Extreme environments demand superior performance, which is why you will find Hubbell products and systems installed in some of the most arduous and safety critical
More informationDräger Polytron 8100 EC Detection of toxic gases and vapors
Dräger Polytron 8100 EC Detection of toxic gases and vapors The Polytron 8100 EC is Dräger s top of the line explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance
More informationDräger Polytron 8310 IR Detection of flammable gases and vapour
Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationDräger Polytron 8100 EC Detection of toxic gases and oxygen
Dräger Polytron 8100 EC Detection of toxic gases and oxygen The Polytron 8100 EC is Dräger s top of the line explosion-proof transmitter for the detection of toxic gases or oxygen It uses a high performance
More informationDB4 Range - SPEAKERS - Up to 25 Watts
DB Range - SPEAKERS - Up to 5 Watts Hazardous Location, Weatherproof Features UL listed for USA and Canada Class I, Div, Groups A, B, C & D. Class I, Zone, AExd IIC T. CSFM approved. ATEX approved. NEMA
More informationIntegrated Solutions Low Voltage Systems
Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY
More informationHubbell Harsh & Hazardous. Our Brands. Corporate Information
www.chalmit.com Hubbell Harsh & Hazardous Extreme environments demand superior performance, which is why you will find Hubbell products and systems installed in some of the most arduous and safety critical
More informationBC9700 series High Power LED Explosion Proof Light
BC9700 series High Power LED Explosion Proof Light Characteristics IECEx ATEX LM79 LM8 IP 66 Ta 0/55 Ta -0 Application Zone,zone ;zone,zone Suitable for Low installation height in Moist corrosive environment,such
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance
More informationPYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white
. TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8
More informationCCTV quick connect Harsh and Hazardous area connectors for camera stations
CCTV solutions Multi-pin connectors CROUSE-HINDS SERIES CCTV quick connect Harsh and Hazardous area connectors for camera stations Part of our wider solution for hazardous environments PA / GA Designed,
More informationATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres
Includes NEW LinkEx LE Wolf Safety Lamp Company The widest range of portable ATEX lighting approved for use in explosive atmospheres Wolf Safety have Ex lighting products for all purposes, the correct
More informationSPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications
ZONE 1 ZONE 2 INDUSTRIAL SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications ATEX and IEC Ex approved Zone 1 Zone 2 variant also available Ultra long life LED High lumen output LED Easy installation,
More information120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable
120W Hazardous Location LED Fixture - 12-24V DC - Modbus TCP/IP - Network Controlled - Dimmable Part #: HAL-ANC-60-120W-ITG-LED-DIMM-1224 Page: 1 The Larson Electronics HAL-ANC-60-120W-ITG-LED-DIMM-1224
More informationEXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW
EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN S 1,21 & 2,22 KDB 150049X NEW WORK WITH GDANSK / Poland ABOUT US ATM Lighting is a Polish manufacturer of technical light fittings for various industry sectors.
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationTPPL TUBULAR PROFESSIONAL PERFORMANCE LIGHTING SMART LIGHTING FOR HARSH ENVIRONMENTS
TPPL TUBULAR PROFESSIONAL PERFORMANCE LIGHTING SMART LIGHTING FOR HARSH ENVIRONMENTS ATEX DIRECTIVES The ATEX directives 2014/34/EU & 1999/92/EC are commonly referred to as the two European Directives
More informationMicro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications
Micro and Mini Zones: 0, 1, 2, 20, 21 and 22 Product Overview Features & Benefits The Micro and Mini es use high-tech light sources to give impressive performance with a compact size, designed for easy
More informationIndustrial & Hazardous Area Electrical Equipment
Industrial & azardous Area Electrical Equipment 2017 Abtech has been supplying electrical connection products to hazardous and industrial markets since the 1970 s. Our range includes hazardous area lighting,
More informationHelyum. Feam Product Brochure LOCATION CERTIFICATES REFERENCES. Milan / ITALY ATEX, IECEX, EX GOST, INMETRO, NEC500-5
2016 Feam Product Brochure LOCATION Milan / ITALY- 1961 CERTIFICATES ATEX, IECEX, EX GOST, INMETRO, NEC500-5 REFERENCES Eni, Saipem, Tecnimont, GE Oil Gas, Technip, ABB Group, Foster Wheeler, Saudi Aramco,
More informationExplosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationTBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22
Hazardous Area Electrical Equipment Made TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBSF/CBSF Information Page
More informationINSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING
More informationstandards: standards:
INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD
More informationPhoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.
Phoenix Explosion-proof Pan & Tilt heads and Camera Housings for potentially exposed environments Answers for infrastructure. Video monitoring under extreme conditions Security Products from Siemens is
More informationCoreLine Batten the clear choice for LED
Lighting CoreLine Batten the clear choice for LED CoreLine Batten Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light and substantial
More informationFlameproof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationofficial distributor of Newson Gale Ltd.
Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container
More informationDräger Polytron 8200 CAT Detection of flammable gases and vapors
Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit
More informationDistributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires
Distributed by ECO LIGHT PRODUCT OVERVIEW Hazardous Area Luminaires UK Designed and Manufactured All Raytec hazardous area products are designed and manufactured in the UK and are ATEX and IEC Ex approved.
More informationQuick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly
Quick Start Guide 00825-0200-2654, Rev EA Rosemount 0065/0185 Sensor Assembly Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0065 and 0185 Sensor models. It does not provide
More informationElectrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL390LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,
More informationEngineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage
Engineering Safety & Productivity Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage Champ FMV LED Series Floodlight Fixtures High-performance,
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296
More informationRosemount 752 FOUNDATION Fieldbus Remote Indicator
Rosemount 752 FOUNDATION Fieldbus Remote Indicator Product Data Sheet 00813-0100-4377, Rev FA Two-wire segment powered device Displays up to eight values Link Master Capability Optional PID, Characterizer,
More informationHazardous Area Portable Fan Heater The Bulldog
Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable
More informationHazardous Area Portable Fan Heater The Bulldog
Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable
More informationCCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.
Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw
More informationFloodlights. In this section.
In this section 5.1 s 5.3 Metal Halide Floodlights 5.3 High Pressure Sodium Floodlights 5.4 Energy Saver Floodlights 5.4 LED Floodlights www.ecolifelighting.co.nz Floodlights Floodlights Floodlighting
More informationInspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,
More informationREGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC
EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or
More informationCertification Supplement Manual
SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN
More informationdistributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:
distributed by Sole Agent in reat China Universky (Jiangsu) Technologies, Inc. #7 Belt Lake (Lian hu) Industrial Park, anyang, Jiangsu, China 212300 Phone: +86 511 86537777 Fax: +86 511 8628263 E-mail:
More informationRosemount 214C Sensor. Quick Start Guide , Rev AF August 2017
Rosemount 214C Sensor 00825-0400-2654, Rev AF NOTICE This guide provides basic guidelines for Rosemount 214C Sensor models. If the sensor was ordered assembled to a temperature thermowell or transmitter,
More informationWE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS
WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS 100+ YEARS Federal Signal is recognized as one of the industry s leading suppliers of safety
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The
More informationPILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS
PENTAIR CLEAN AIR SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition
More informationHazardous Areas - EXPLOSIONPROOF SOLENOIDS
Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas
More informationChamp-Pak Wall Pack Luminares
Champ-Pak Wall Pack Luminares Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F, G Cl. III & Simultaneous
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified
More informationUL HAZARDOUS LOCATIONS SERVICES
UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,
More informationHazardous Area Portable Fan Heater The Bulldog
Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable
More informationHAZARDOUS AREA SOLUTIONS
HAZARDOUS AREA SOLUTIONS Lighting ATEX Zones 0,1, 2, 20, 21 and 22 v. 2.0/16 2 Delvalle, wide experience in manufacturing solutions for hazardous area WE PUT AT YOUR DISPOSAL We offer over 40 years providing
More informationGas cylinder scale Model GCS-1
Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in
More informationEVLPF Series Compact Fluorescent
EVLPF Series Low Profile Hazard Gard Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence