CAP Series ,,,,, The Clear Choice. CAP Series Features: Who Says Infrared Windows Have to be Round? Certifications:

Size: px
Start display at page:

Download "CAP Series ,,,,, The Clear Choice. CAP Series Features: Who Says Infrared Windows Have to be Round? Certifications:"

Transcription

1 CAP Series Who Says Infrared Windows Have to be Round? The durability and proven transmission stability o our patented reinforced polymer is the cornerstor of the CAP Series. Traditional round infrared (IR) windows are made 2" - 4" diameters. This is primarily because increas the diameter and maintaining the thickness exponentially increases the fragility of the crystal, making larger sizes weaker and cost prohibitive. Available in 6'; 12'; and 24" widths, CAP Series IR windows allow inspection of multiple component through one window, reducing the total number, windows, associated installation time, and costs. CAP-12 shown above, CAP-C-6 shown to right, with cover open IRISS,,,,, CAP Series Features: Durable, fully impact-resistant Fixed And Stable Transmission (FAST) Proven compatibility with acids, alkalis, UV, moisture, humidity, vibration, and high frequency noise Reinforcing grills comply with IP2x standard for safe maximum hole size and fail-safe design Optional cover with locking catches Customizable; if you don't see what you need in the standard offering you can configure: Housing Locking Devices Labeling Color Fitting templates and instructions Standard product constructed of aluminum; custom materials available UL 746 compliant, IR transmissive polymer; -40 c (-40 F) to 325 c (617 F) UL 94 5VA TPE; -40 C (-40 F) to 273 C (523 F) Recognized by UL in the USA & UL50V UL50E UL 746C: UL1558: ULS08A;ANSIUL508A IEEE C a.3.6: IP65/ NEMA 4 Lloyds of London Type Approval American Bureau of Shipping (ABS) Model IRWindow Overall CAP-6, CAP-C-6 A=9.1 cm (3.6 in), 8=15 cm (5.9 in) C= 16 cm (6.3 in), 0=21.8 cm (8.6 in) CAP-12, CAP-C-12 A=23.6 cm (9.3 in), 8=12.7 cm (5.0 in) C=30.5 cm (12.0 in}, 0=20.6 cm (8.1 in) CAP-24, CAP-C-24 A=53 cm (20.9 in), 8=15 cm (5.9 in) C=61 cm (24.0 in}, 0=21.8 cm (8.6 in)

2 Platinum Series CAP-CT No Infrared Window is as Versatile as the Platinum Series CAP-CT Surpassing even the original industral-grade CAP Series, the NEW Platinum Series CAP-CT has the largest visually clear infrared (IR) transmissive viewing area with cover available. The exclusive pharmaceutical-grade reinforced Poly-View polymer allows any thermography camera to monitor completely undisturbed assets inside electrical equipment in the visual, ultraviolet, and shortwave, midwave and longwave IR ranges. The larger rectangular viewing area provides an unparalleled field of view when compared to traditional round IR windows. Platinum Series CAP-CT-12 shown, with cover open Platinum Series CAP-CT Features: The world's largest indsutrial-grade IR window series Combined visual and IR window allows for greater flexibility Durable, fully impact-resistant, pharmaceutical-grade optics Fuxed And Stable Transmission (FAST) Proven compatibility with acids, alkalis, UV, moisture, humidity, vibration, and high frequency noise Reinforcing grills comply with IP2x standard for safe maximum hole size and fail-safe design Customizable; if you don't see what you need in the standard offering you can configure: Housing Locking Devices Labeling Color Fitting templates and instructions Standard product constructed of aluminum; custom materials available UL 746 compliant, visual and IR transmissive polymer; -40 ( (-40 F) to 325 ( (617 F) UL 94 5VA TPE; -40 ( (-40 F) to 273 ( (523 F) Recognized by UL in the USA & UL S0V UL50E UL 746(: UL1558 : UL508A;ANSIUL508A IEEE C a.3.6: IP65/ NEMA 4 Llloyds of London Type Approval American Bureau of Shipping (ABS) Model Window Overall CAP-CT-6 A=9.1 cm (3.6 in), 8=15 cm (5.9 in) C=16 cm (6.3 in), D=21.8 cm (8.6 in) CAP-CT-12 A=23.6 cm (9.3 in), 8=12.7 cm (5.0 in) C=30.S cm (12.0 in), 0=20.6 cm (8.1 in) CAP-CT-24 A=53 cm (20.9 in), 8=15 cm (5.9 in) C=6 1 cm (24.0 in), 0=21.8 cm (8.6 in)

3 Platinum Series CAP-T No Infrared Window is as Large as the Platinum Series CAP-T Surpassing even the original industral-grade CAP Series, the NEW Platinum Series CAP-T has the largest visually clear infrared (IR) transmissive viewing area available. The exclusive pharmaceutical-grade reinforced Poly-View polymer allows any thermography camera to monitor completely undisturbed assets inside electrical equipment in the visual, ultraviolet, and shortwave, midwave, and longwave IR ranges. The larger rectangular viewing area provides an unparalleled field of view when compared to traditional round IR windows. Platinum Series CAP-T shown Platinum Series CAP-T Features: The world's largest industrial-grade IR window series Combined visual and IR window allows for greater flexibility Durable, fully impact-resistant, pharmaceutical-grade optics Fuxed And Stable Transmission (FAST) Proven compatibility with acids, alkalis, UV, moisture, humidity, vibration, and high frequency noise Reinforcing grills comply with IP2x standard for safe maximum hole size and fail-safe design Customizable; if you don't see what you need in the standard offering you can configure: Housing Locking Devices Labeling Color Fitting templates and instructions Window Housing Standard product constructed of aluminum; custom materials available UL 746 compliant, visual and IR transmissive polymer; -40 C (-40 F) to 32S C (617 F) UL 94 SVA TPE; -40 ( (-40 F) to 273 ( (523 F) Recognized by UL in the USA & ULSOV UL SOE UL 746C: UL1558: UL SOSA; ANSI UL SOSA IEEE C a.3.6: IP6S /NEMA 4 Llloyds of London Type Approval American Bureau of Shipping (ABS) Model Window Overall CAP-T-6 A=9.1 cm (3.6 in), B= 15 cm (S.9 in) C=16 cm (6.3 in), 0=21.8 cm (8.6 in) CAP-T-12 A=23.6 cm (9.3 in), 8=12.7 cm (S.O in) C=30.S cm (12.0 in), 0=20.6 cm (8. 1 in) CAP-T-24 A=S3 cm (20.9 in), B=l 5 cm (5.9 in) C=61 cm (24.0 in), 0=21.8 cm (8.6 in)

4 CAP-V Series The World's Only Impact-Resistant Infrared and Visual Window Series The CAP-V Series adds a visual viewing pane that allows visual and infrared (IR) inspections to be completed simultaneously. The entire CAP Series was designed to comply with all mandatory impact, load, and flammability requirements. (Industrial standards NO crystal or non-reinforced polymer IR window can possibly meet.) The CAP-VC offers locking covers for your IR window. These are useful in areas of high traffic and protect the IR and visual viewing panes from impacts, flying debris and dust. Available in two protective cover options: CAP-VC range offers a protective cover for the IR window CAP-VCH-12 shown, with cover open CAP-VCH range offers a single cover for both IR window and visual viewing pane CAP-V Series Features: Seperate visual and IR viewing panes allow for dual inspection Durable, fully impact-resistant Fixed And Stable Transmission (FAST) Proven compatibility with acids, alkalis, UV, moisture, humidity, vibration, and high frequency noise Reinforcing grills comply with IP2x standard for safe maximum hole size and fail-safe design Optional cover with locking catches Customizable; if you don't see what you need in the standard offering you can configure: Housing Locking Devices Labeling Color Fitting templates and instructions Standard product construction of aluminum; custom materials available UL 746 compliant, IR transmissive polymer; -40 C (-40 F) to 325 c (6 17 F) UL 94 5VA TPE; -40 C (-40 F) to 273 C (523 F) Recognized by UL in the USA & ULS0V UL50E UL 746C: UL1558: UL508A;ANSIUL508A IEEE C a.3.6: IP65/NEMA 4 Lloyds of London Type Approval American Bureau of Shipping (ABS) I It. 11r aa <----- Model CAP-V-6, CAP-VC-6, CAP-VCH-6 CAP-V-12, CAP-VC-12, CAP-VCH-12 CAP-V-24, CAP-VC-24, CAP-VCH-24 Visual Window IRWindow A=9.7 cm (3.8 in), C=9. 1 cm (3.6 in), B=5 cm (1.95 in) D=5.8 cm (2.3 in) A=23.9 cm (9.4 in}, C=23.6 cm (9.3 in), B=5 cm (1.95 in) D=5.8 cm (2.3 in) A=54.1 cm (21.3 in), C=53 cm (20.9 in), B=5 cm (1.95 in) 0=5.8 cm {2.3 in) Overall E=16 cm (6.3 in), F=21.8 cm (8.6 in} E=30.5 cm (12.0 in), F=20.6 cm (8.1 in) E= 61 cm (24.0 in), F= 21.8 cm (8.6 in)

5 TM Custom Solutions Sized to fit your application It s Time Your IR Window Fitted Your Needs and Applications IRISS is the only global infrared (IR) window manufacturer with solutions for unique applications. Custom Solutions from IRISS ensure that your IR window meets your needs and applications. IRISS understands that not every application is suitable for a standard IR window. The patented IRISS reinforced optic is flexible and can be manufactured in an infinite number of shapes and sizes. This allows the IR industry safe access to energized targets previously considered impossible. Direct temperature measurement is now available on those unique applications without the increased risk associated with removing covers or guards. Consult with your IRISS representative to design a custom solution that will protect your personnel, critical equipment, and processes. Custom TPC with Thermal Image Inset Custom Solutions Features: Poly-View technology enables viewing in the visual, UV, and shortwave, midwave, and longwave IR spectrums for your exact requirements Thermographers gain full access to view connections, absent risks associated with panel removal Fixed And Stable Transmission (FAST) Proven compatibility with acids, alkalis, UV, moisture, humidity, vibration, and high frequency noise Patented design complies with IP2x standard for safe maximum hole size and fail-safe design Monitoring procedure is non-invasive, faster, and safer, saving you time and money Data collection under peak load makes identification of faults more accurate and easier Durable, fully impact-resistant, pharmaceutical-grade optics Optional covers with locking catches Easily Monitor: UPS Systems Long Rows of Connections Multiple Connections Located Close to Window Commutator Slippage Couplings Under Guards Mechanical Systems Behind Polycarbonate or Metal Guards Before and After Customization (Transmissive Panel Cover) CAP-V-24 Installed High-Value Electric Motor Commutator Block Window (Cover Removed for Display) Created for a Tier 1 Switchgear Manufacturer 3in x 67in Viewing Area

6 TM VP-12-IR Features: VP-12-IR The world s only industrial-grade IR window series Fixed And Stable Transmission (FAST) Because Sometimes a Smaller Infrared Made especially for small targets or Window is All You Need small IR camera lens apertures Lockable cover maintains IP65/NEMA 4 seal when closed and open The VP-12-IR s 12mm viewing area was designed for tight 1.2 cm (0.5 inch) port complies with areas or for use with infrared (IR) cameras with smaller, wider IP2x standard for safe maximum hole angle lens systems. size in switchgear to prevent accidental insertion of tools and body parts While the VP-12-IR is small in size, it is still big on features. Bodies manufactured using The polymer lens material and switchgear-grade plastics non-conductive, UL 94 switchgeargrade plastics, insulated to 30kV/mm assures compliance by maintaining an IP65/NEMA 4 seal whether open or closed. This keeps your equipment in a Impact and flame resistant as per UL closed and guarded condition, allowing your thermographers and IEEE standards to work safely and efficiently. Optional Easy-Grip TM stainless steel cover With the smaller footprint of the VP-12-IR, it could be the Fitting templates and instructions answer for providing a thermographer access to more challenging areas. This will allow monitoring of equipment that would not have been possible with a larger window. The durability, flexibility and proven transmission stability of IRISS polymer IR windows continues with the VP-12-IR. Optional Easy-Grip TM stainless steel cover available. - UL 746C: IEEE C a.3.6: UL 94 5VA Nylon (switchgear-grade plastic); -40 C (-40 F) to 273 C (523 F); optional Easy-Grip TM stainless steel cover UL 746 compliant, IR transmissive polymer; -40 C (-40 F) to 325 C (617 F) Model Body Diameter Port Diameter Assembly Thickness VP-12-IR, VP-12-IR-M 6.5 cm (2.6 in) 1.2 cm (0.5 in) 2.6 cm (1.0 in)

7 TM... VP-12-US Features: VP-12-US 1.2 cm (0.5 in) port opening complies with IP2x standard for safe maximum Versatile Port for Ultrasound Inspection hole size in switchgear to prevent accidental insertion of tools and body parts A standard and systematic approach to data collection is Lockable cover maintains IP65/NEMA essential to establishing a repeatable and reproducible 4 seal when closed condition based monitoring program. Bodies manufactured using non-conductive, UL 94 switchgeargrade plastics, insulated to 30kV/mm VP-12-US standardizes location and method for accessing consistent and quality acoustic data regardless Impact and flame resistant as per UL of ultrasound technician experience or enclosure rating. and IEEE standards Easily identify potentially hazardous faults such as arcing, Optional Easy-Grip TM stainless tracking, and corona in electrical distribution systems steel cover and switchgear. Fitting instructions and templates Ventilated switchgear ports standardize the measurement point. NEMA rated enclosures require only access through the port where technicians can safely collect data on energized equipment in accordance with NFPA 70E safety mandates. The grill allows ultrasound but prevents objects being pushed through the hole into the panel. Note: As when opening any port or grill, proper PPE should be identified and worn, since opening the cover removes the barrier between energized conductors and personnel outside the enclosure. - UL 746C: IEEE C a.3.6: Port Housing, Grill and Cover UL 94 5VA Nylon (switchgear-grade plastic); -40 C (-40 F) to 273 C (523 F); optional Easy-Grip TM stainless steel cover IP65 / NEMA 4: when closed Model Body Diameter Port Diameter Assembly Thickness VP-12-US, VP-12-US-M 6.5 cm (2.6 in) 1.2 cm (0.5 in) 2.6 cm (1.0 in)

8 TM TM VPFC Series Features: VPFC Series Transparent crystal allows for Crystal Infrared Windows Calcium Fluoride (CaF2) has long been used in research applications. It performs best in controlled environments where humidity, chemical exposure, vibration, and high frequency noise are minimized or eliminated. The transmission rate characteristics of CaF2 are ideal for higher temperature applications, shortwave and midwave thermography, and for the visual spectrum. Medium to longwave transmission rates (7-14 micron) are typically between 50% and 65% based on the infrared (IR) camera detector sensitivities at different wavelengths. visual inspection Compatible with all IR cameras UV transmission compatible with all corona cameras Housing made of switchgear-grade plastics; insulated to 30kV/mm, non-conductive and UL 94 compliant Easy-Grip TM stainless steel cover Available in 2, 3, and 4 sizes (actual crystal viewing area) Fitting instructions and templates VPFC (Viewing Pane Fixed Crystal) Series IR windows are specially coated to reduce the transmission drift due to moisture/humidity. However, industrial users are strongly encouraged to investigate the VPFR Series of industrial-grade IR windows which are specifically designed for stability in harsh industrial environments. When purchasing crystal windows, ask for the Material Safety Data Sheet (MSDS) to ensure that the crystal does not contain hazardous substances. Some window manufacturers use crystals made of Barium Flouride (BaF2), a toxic substance, especially hazardous to the food and beverage industry. Note: No crystal widow meets impact requirements for switchgear above 1kV (IEEE C a.3.6). UL 94 5VA Nylon (switchgear-grade plastic); -40 C (-40 F) to 273 C (523 F); Easy-Grip TM stainless steel cover Calcium Flouride Crystal (other crystal options available); -100 C (-148 F) to 1400 C (2555 F) Model Body Diameter Window Diameter Assembly Thickness VPFC cm (3.6 in) 5.1 cm (2.0 in) 2.6 cm (1.0 in) VPFC cm (4.8 in) 7.6 cm (3.0 in) 2.6 cm (1.0 in) VPFC cm (5.95 in) 10.2 cm (4.0 in) 2.6 cm (1.0 in)

9 TM VPFR Series Features: VPFR Series The world s only industrial-grade The World s Only Impact-Resistant Infrared Window Industrial-grade VPFR Series (Viewing Pane Fixed Reinforced) infrared (IR) windows enable thermographers to survey critical electrical applications efficiently and safer than ever. NFPA standards recommend IR inspection under fully energized conditions. However, PPE requirements, panel cover removal, and reinstallation are time consuming and costly. Use of the VPFR Series IR windows nearly eliminates the risks associated with IR electrical inspection by providing companies with a non-invasive, closed-panel inspection methodology. IR window series Fixed And Stable Transmission (FAST) Unconditionally guaranteed against transmission loss for accurate qualitative and quantitative analysis Durable, fully impact-resistant Patented reinforced grill exceeds high voltage switchgear viewing pane standards Manufactured from non-conductive UL 94 plastics insulated to 30kV/mm Fitting templates and instructions Thermographers using IR windows are never exposed to energized conductors or circuit parts and are not engaged in risk increasing behaviors. Therefore, elevated levels of PPE for invasive surveys are not required, minimizing survey time while maximizing safety. - UL 746C: IEEE C a.3.6: Reinforcing Grill UL 94 5VA Nylon (switchgear-grade plastic); -40 C (-40 F) to 273 C (523 F) UL 746 compliant, IR transmissive polymer; -40 C (-40 F) to 325 C (617 F) Aluminum coated with UL 94 5VA Nylon; -40 C (-40 F) to 273 C (523 F) Model Body Diameter Window Diameter Assembly Thickness VPFR cm (3.6 in) 5.1 cm (2.0 in) 2.6 cm (1.0 in) VPFR cm (4.8 in) 7.6 cm (3.0 in) 2.6 cm (1.0 in) VPFR cm (5.95 in) 10.2 cm (4.0 in) 2.6 cm (1.0 in)

10 TM VPFR-M Series Features: VPFR-M Series The world s only industrial-grade The World s Only Impact-Resistant Infrared Window Equipped with an Easy-Grip TM Stainless Steel Cover Industrial-grade VPFR-M Series (Viewing Pane Fixed Reinforced) infrared (IR) windows enable thermographers to survey critical electrical applications efficiently and safer than ever. NFPA standards recommend IR inspection under fully energized conditions. However, PPE requirements, panel cover removal, and reinstallation are time consuming and costly. Use of the VPFR-M Series IR windows nearly eliminates the risks associated with IR electrical inspection by providing companies with a non-invasive, closed-panel inspection methodology. IR window series Fixed And Stable Transmission (FAST) Unconditionally guaranteed against transmission loss for accurate qualitative and quantitative analysis Durable, fully impact-resistant Patented reinforced grill exceeds high voltage switchgear viewing pane standards Manufactured from non-conductive UL 94 plastics insulated to 30kV/mm Easy-Grip stainless steel cover Fitting templates and instructions Thermographers using IR windows are never exposed to energized conductors or circuit parts and are not engaged in risk increasing behaviors. Therefore, elevated levels of PPE for invasive surveys are not required, minimizing survey time while maximizing safety. - UL 746C: IEEE C a.3.6: Reinforcing Grill UL 94 5VA Nylon (switchgear-grade plastic); -40 C (-40 F) to 273 C (523 F); Easy-Grip TM stainless steel cover UL 746 compliant, IR transmissive polymer; -40 C (-40 F) to 325 C (617 F) Aluminum coated with UL 94 5VA Nylon; -40 C (-40 F) to 273 C (523 F) Model Body Diameter Window Diameter Assembly Thickness VPFR-M cm (3.6 in) 5.1 cm (2.0 in) 2.6 cm (1.0 in) VPFR-M cm (4.8 in) 7.6 cm (3.0 in) 2.6 cm (1.0 in) VPFR-M cm (5.95 in) 10.2 cm (4.0 in) 2.6 cm (1.0 in)

11 TM The Clear Choice Platinum Series VPT The world s only clear polymer The Next Generation of Infrared Windows An evolutionary step in infrared (IR) windows, the Platinum Series VPT utilizes our exclusive Poly-View technology to allow the use of any thermography camera to monitor electrical equipment. The world s only clear polymer window provides for visual inspections, traditional IR inspections utilizing cameras across the entire IR spectrum, and allows for UV inspections to be performed with a corona camera. The Platinum Series VPT IR windows are industrialgrade with a patented reinforced grill that exceeds high voltage switchgear viewing pane standards. Poly-View Visual Ultraviolet Shortwave IR Midwave IR Longwave IR Platinum Series VPT Features: industrial-grade IR window series Poly-View technology enables viewing in the visual, UV, and shortwave, midwave, and longwave IR spectrums Fixed And Stable Transmission (FAST) Clear pharmaceutical-grade optics Unconditionally guaranteed against transmission loss for accurate qualitative and quantitative analysis Durable, fully impact-resistant Available in 2, 3, and 4 sizes (actual viewing area) Easy-Grip stainless steel cover Fitting templates and instructions - UL 746C: IEEE C a.3.6: Reinforcing Grill UL 94 5VA Nylon (switchgear-grade plastic); -40 C (-40 F) to 273 C (523 F); Easy-Grip TM stainless steel cover UL 746 compliant, visual and IR transmissive polymer; -40 C (-40 F) to 325 C (617 F) Aluminum coated with UL 94 5VA Nylon; -40 C (-40 F) to 273 C (523 F) Model Body Diameter Window Diameter Assembly Thickness VPT cm (3.6 in) 5.1 cm (2.0 in) 2.6 cm (1.0 in) VPT cm (4.8 in) 7.6 cm (3.0 in) 2.6 cm (1.0 in) VPT cm (5.95 in) 10.2 cm (4.0 in) 2.6 cm (1.0 in)

VPFR. cma. Product Brochure. Industrial-Grade Infrared Inspection Viewing Panes

VPFR. cma. Product Brochure. Industrial-Grade Infrared Inspection Viewing Panes VPFR Industrial-Grade Infrared Inspection Viewing Panes m n issi g u ve been o y See what Product Brochure cma VPFR The adoption of infrared (IR) inspection windows in industrial applications grows exponentially

More information

INFRARED WINDOW SERIES

INFRARED WINDOW SERIES XDV SERIES IR & VISUAL INSPECTION WINDOW INFRARED WINDOW SERIES TURTLE TOUGH IR WINDOWS RANGE offers you a more EFFICIENT & SAFE PROCESS to perform visual & INFRARED INSPECTIONS Our products: LARGE-FORMAT

More information

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance.

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. ndustr Proce Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Electric Why open enclosures and expose yourself to arc flash hazards when you don t have to? Infrared

More information

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Fluke-Direct.com

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Fluke-Direct.com ndustr Proce Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Electric Outdoor/indoor any voltage, arc-tested Indoor medium voltage Indoor low voltage info@ Available

More information

White paper. OSHA and NFPA 70 Safer by Design The History of IRISS. Infrared Windows. Abstract: iriss.com

White paper. OSHA and NFPA 70 Safer by Design The History of IRISS. Infrared Windows. Abstract: iriss.com OSHA and NFPA 70 Safer by Design The History of IRISS By Martin Robinson, CMRP Level III Thermographer President, IRISS Inc. Abstract: As CEO and Founder of IRISS, Inc., I am often asked how and why I

More information

Common Misconceptions Relating to Infrared Inspection Ports

Common Misconceptions Relating to Infrared Inspection Ports Common Misconceptions Relating to Infrared Inspection Ports Martin Robinson, Managing Director Global Maintenance Technologies Chelford Court, Robjohns Road Chelmsford, Essex CM1 3AG United Kingdom Ph:

More information

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com A Geothermal Energy Generation Facility Embraces Infrared Polymer Window Inspections By Dominique Capili, Spectrum Scientific Corporation (An IRISS Distributor) Overview: A prominent geothermal energy

More information

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2 Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2 By: Martin Robinson, CEO of IRISS Group and Level III Thermographer Abstract Every year thousands electrical workers are injured

More information

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com Reducing Arc Flash Risks with Electrical Maintenance By Martin Robinson, CMRP Level III Thermographer President, IRISS Inc. Abstract: Electrical accidents, such as arc flashes, happen daily; however, there

More information

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com Custom Solutions for High Arc Flash Incident Energy and Interlocked Electrical Enclosures By Mark Bowling, Level II Thermographer, IRISS Inc. & Rick Miner, Level III Thermographer, Thermal Techniques Overview:

More information

A Powerful Case for Infrared Windows

A Powerful Case for Infrared Windows ROI A Powerful Case for Infrared Windows By Martin Robinson, CMRP Level III Thermographer CEO, IRISS, Inc. Overview: A regional Facility had been tasked by their insurance carrier to perform regular preventive

More information

White Paper. Maintenance Inspection Windows on Transformers. Maintenance Inspection Windows on Transformers. Abstract: iriss.com

White Paper. Maintenance Inspection Windows on Transformers. Maintenance Inspection Windows on Transformers. Abstract: iriss.com Maintenance Inspection Windows on Transformers By Rudy Wodrich, P.Eng., MBA, CRL, VP Engineering Services, IRISS Inc. Abstract: Everyone knows that Thomas Alva Edison invented the lightbulb but who invented

More information

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss. NFPA 70E 2018 Edition Changes and Implications for Personnel Performing Condition Based Maintenance By Rudy Wodrich, P.Eng., MBA, CRL, L1 Thermographer, VP Engineering Services, IRISS Inc. Abstract: The

More information

Broadening IR applications through using spectral filters

Broadening IR applications through using spectral filters Broadening IR applications through using spectral filters Inframetrics-Europe, Meche/sesteenweg 277, B-1800 Vilvoorde, Belgium Tel. (32) 2 257 90 30, Fax. (32) 2 257 90 39, e-mail: guy.pas@inframetrics.be

More information

IR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows

IR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows IR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows Abstract There exists a dangerous misconception regarding the Arc Rating of IR viewing windows or viewing panes.

More information

White Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com

White Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010 By Martin Robinson, CMRP Level III Thermographer President, IRISS Inc. Abstract: The National Fire Protection

More information

INSPECT & MONITOR 24/7 SOLUTIONS FOR ELECTRICAL CABINETS. IR Windows & AX8 Thermal Imaging Temperature Sensor

INSPECT & MONITOR 24/7 SOLUTIONS FOR ELECTRICAL CABINETS. IR Windows & AX8 Thermal Imaging Temperature Sensor INSPECT & MONITOR 24/7 SOLUTIONS FOR ELECTRICAL CABINETS IR Windows & AX8 Thermal Imaging Temperature Sensor FLIR Solutions FLIR HAS A CABINET MONITORING SOLUTION FOR YOU If your cabinet-monitoring routine

More information

Infrared Windows and Arc Ratings: Dispelling the Myth of Arc-Resistant IR Windows

Infrared Windows and Arc Ratings: Dispelling the Myth of Arc-Resistant IR Windows Infrared Windows and Arc Ratings: Dispelling the Myth of Arc-Resistant IR Windows Tim Rohrer, VP of Sales & Marketing Martin Robinson, President and IRISS, Inc. 4914 Lena Road, Suite 105 Bradenton, FL

More information

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER ClirVu Series IR Windows Safety shouldn t be secondary If Fluke has learned anything in more than 65 years, it s not to compromise

More information

Compliance without compromise Safety without sacrifice

Compliance without compromise Safety without sacrifice Compliance without compromise Safety without sacrifice YOUR RESULTS MATTER ClirVu Series IR Windows Safety shouldn t be secondary If Fluke has learned anything in more than 65 years, it s not to compromise

More information

FREE TE POWER BANK. Power bank colour chosen at random

FREE TE POWER BANK. Power bank colour chosen at random LV JUICE March 2016 FREE WHILE STOCKS LAST HEATSHRINK RNF DWP MWTM WCSM CNSM CRSM DCPT FCSM LVIT EZISHRINK Raychem heatshrink products shrink to fit a range of different sizes and types of cables, and

More information

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID) Open-area Smoke Imaging Detection (OSID) OSID Smoke Detection Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual

More information

UNDERSTANDING SAFETY CABINETS

UNDERSTANDING SAFETY CABINETS UNDERSTANDING SAFETY CABINETS Why use safety cabinets? What makes a safety cabinet safe? How to choose the right safety cabinet Reduce fire risks and safely organize, segregate, and store flammable fuels,

More information

A WORLD WITHOUT DOWNTIME

A WORLD WITHOUT DOWNTIME ELECTRICAL INFRARED INSPECTION High temperatures may indicate excessive electrical resistance, failing components, ground faults, short circuits or other common problems in equipment that can lead to expensive

More information

Enhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08

Enhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08 2 Table of Contents Enhancing Current Maintenance Practices 04 Managing the Risk 06 Constant Monitoring of Electrical Enclosures 08 Delta T Alert A Simple Device with Staggering Results 10 An Easy Way

More information

infrared inspections efficient solutions. focused results.

infrared inspections efficient solutions. focused results. infrared inspections efficient solutions. focused results. efficient solutions. focused results. Infratech is a Canadian company incorporated in 1987 that is focused on providing industry leading products

More information

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In? NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In? Adrian Messer, Manager of US Operations UE Systems, Inc. Ph: 864-224-4517 Cell: 914-282-3504 Web: www.uesystems.com

More information

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions The Most Versatile Flame Detectors in the World Optical Flame Detection Solutions The Global Leader in Flame Detection Superior Performance and Reliability Flame detection is the very essence of the proud

More information

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions The Most Versatile Flame Detectors in the World Optical Flame Detection Solutions The Global Leader in Flame Detection Superior Performance and Reliability Flame detection is the very essence of the proud

More information

Predictive Maintenance Training

Predictive Maintenance Training Predictive Maintenance Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq This predictive maintenance

More information

Are Electrical Switchgear Surveys Still the Low-Hanging Fruit of Infrared Thermography?

Are Electrical Switchgear Surveys Still the Low-Hanging Fruit of Infrared Thermography? Are Electrical Switchgear Surveys Still the Low-Hanging Fruit of Infrared Thermography? Gregory R. Stockton, President Stockton Infrared Thermographic Services, Inc. & United Infrared, Inc. 8472 Adams

More information

SEL Arc-Flash Solutions

SEL Arc-Flash Solutions SEL Arc-Flash Solutions Arc-Flash Protection at the Speed of Light Protect personnel and equipment Detect arc-flash events and send a trip signal in as little as 2 ms to enhance safety and minimize equipment

More information

Electrical Safety Compliance: NFPA 70E

Electrical Safety Compliance: NFPA 70E Electrical Safety Compliance: NFPA 70E From Graybar and Schneider Electric Risks associated with shock and electrocution from inadvertent contact with energized parts have long been recognized as a threat

More information

SEL Arc-Flash Solutions

SEL Arc-Flash Solutions SEL Arc-Flash Solutions Arc-Flash Protection at the Speed of Light Protect personnel and equipment. Detect arc-flash events and send a trip signal in as little as 2 ms to enhance safety and minimize equipment

More information

Optech Thermal IR Sensing Solutions Expanding the Industry

Optech Thermal IR Sensing Solutions Expanding the Industry Optech Thermal IR Sensing Solutions Expanding the Industry Optech Overview Strategic Growth through acquisitions of camera manufacturers 20 Years of Patented & Proven Camera System Experience Broader Imaging

More information

T.ex Single Gas Detector VISA

T.ex Single Gas Detector VISA T.ex Single Gas Detector The T.ex is newest instrument in the Promat portfolio. The instrument is currently available in Oxygen, Hydrogen Sulphide and Carbon Monoxide versions. A Bump Test Station is available

More information

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID) Open-area Smoke Imaging Detection (OSID) www.xtralis.com/osid Large, open spaces warehouses, airports, train stations, stadiums and shopping malls pose unique challenges to reliable fire detection due

More information

Why are infrared cameras indispensable for building inspections?

Why are infrared cameras indispensable for building inspections? Why are infrared cameras indispensable for building inspections? What is infrared thermography? Thermography, also called thermal imaging, is the production of non-contact infrared or heat pictures from

More information

>WIRELESS> ALARM SYSTEM CR200

>WIRELESS> ALARM SYSTEM CR200 intrusion >WIRELESS> ALARM SYSTEM CR200 INTRUSION HOME SECURITY CR200 is a Modern, Effective and Versatile 20-zone Household Security System. It is packed with simple Plug & Play functionality, designed

More information

Laser safety. Enclosures Laser safety curtain Laser safety screens Laser safety tents Laser safety eyewear

Laser safety. Enclosures Laser safety curtain Laser safety screens Laser safety tents Laser safety eyewear Laser safety Enclosures Laser safety curtain Laser safety screens Laser safety tents Laser safety eyewear 1 Laser safety Spetec is your partner of choice if you are looking to combine laser safety materials

More information

Thermography Report. For: (Client) at: (location)

Thermography Report. For: (Client) at: (location) Thermography Report A SAMPLE INFRARED REPORT INFRARED BUILDING EVALUATION For: (Client) at: (location) Thermography date: 01-01-2013 Thermographer: Dave Sawyer, ITC Level III TIR Outdoor temperature: (Temp)

More information

ISIS SAFETY SYSTEM Installation guide

ISIS SAFETY SYSTEM Installation guide ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly

More information

How to reduce exposure to arc flash hazards

How to reduce exposure to arc flash hazards GE Electrical Distribution How to reduce exposure to arc flash hazards Multiple solutions for new and existing facilities imagination at work Multiple Issues Today s power system engineer must not only

More information

P126FTT Fiber Transfer Terminal

P126FTT Fiber Transfer Terminal PRIMEX P126FTT Fiber Transfer Terminal The P126FTT Fiber Transfer Terminal allows the construction/splice crew to connect fiber during initial deployment without needing to return to the site. The service

More information

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Increased safety and reducing energy consumption with the motion control RPI 01

Increased safety and reducing energy consumption with the motion control RPI 01 User manual Increased safety and reducing energy consumption with the motion control RPI 01 3 m detection distance to control the illumination and temperature of the glass door merchandise in the most

More information

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

Insulation and Protection Enhancing the Reliability of Overhead Power Systems Insulation and Protection Enhancing the Reliability of Overhead Power Systems TE Energy TE Energy provides solutions for substations, underground cable, overhead lines, and railway applications. These

More information

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC Changes to NFPA 70E - The Role of PdM &Safe PdM Work Practices Tim Rohrer Exiscan LLC Tim@Exiscan.com 585-705-7775 Joe Gierlach ABM Joseph.Gierlach@ABM.com 412-394-4678 Preview Electrical Safety Risk Management

More information

100W Portable Explosion Proof LED Light - (2) LED Lamps - Non-Spark Aluminum Base - Inline Switch

100W Portable Explosion Proof LED Light - (2) LED Lamps - Non-Spark Aluminum Base - Inline Switch 100W Portable Explosion Proof LED Light - (2) LED Lamps - Non-Spark Aluminum Base - Inline Switch Part #: EPL-BS-2X70LED-100 Page: 1 The EPL-BS-2X70LED-100 Portable Explosion Proof LED Light from Larson

More information

your dust explosion protection experts

your dust explosion protection experts your dust explosion protection experts HMI Overview Camera Systems Pag. 2 Remote I/O Barriers & Isolators Pag. 3 Purge Pag. 3 Plugs & Receptacles Lighting Pag. 5 Control Stations Pag. 6 Terminal Boxes

More information

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000 Your Global Automation Partner Minimizing Arc Flash Exposure in Industrial Applications White Paper - W1000 Industrial environments present multiple safety challenges, including fire hazards that require

More information

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB.  Paul Lee 17 TH APRIL Switch Board Monitoring Protecting Switchboard Courtesy of ABB. www.fengshengelectric.com.sg Paul Lee Agenda 1. Introduction 2. IEC 61439 3. Why Switchboard Monitoring 4. Switchboard Monitoring

More information

Leveraging Thermal Imaging for Gas Detection

Leveraging Thermal Imaging for Gas Detection Leveraging Thermal Imaging for Gas Detection Ed Kochanek, Eastern Region Sales Director and Mark Boccella FLIR Systems, Inc. 9 Townsend West Nashua, NH 03063 Ph: 866-379-4022 www.flir.com ed.kochanek@flir.com

More information

PUV, PIR and PFO Series BROCHURE

PUV, PIR and PFO Series BROCHURE PUV, PIR and PFO Series BROCHURE JUNHO 2013 ABB Multiwave TM process photometers PUV3402, PIR3502 and PFO3372 Measure vapor and liquid samples in IR, NIR, UV and VIS regions Process photometers PUV3402,

More information

160W High Intensity UV LED Light - UVA/365NM V AC - Acrylic Lens

160W High Intensity UV LED Light - UVA/365NM V AC - Acrylic Lens 160W High Intensity UV LED Light - UVA/365NM - 120-277V AC - Acrylic Lens Part #: GAU-LTL-UVA-500W-LED Page: 1 The GAU-LTL-UVA-500W-LED UV LED Flood Light offers intense UVA light output for industrial

More information

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET NSN: 6665150114797 WIDE SEARCH AREA HAND-HELD METAL DETECTION SET Wide Search Area for Faster and Accurate Screening Operations Search operations allowed even in close proximity of metal reinforced floors

More information

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount Part #: EPL-LED-50W-RT-JB2 Page: 1 The Larson Electronics EPL-LED-50W-RT-JB2 Explosion Proof High Bay light

More information

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors. Fire Sentry Corporation (FSC) 593 Apollo Street Tel.: 714-671-1100 Brea, California 92821 Fax: 714-671-5821 Multi-Spectral, Digital, Infrared Electro-Optical FSC Model No. s FS10-R and FS10-A Unitized,

More information

Fiber Distribution Box

Fiber Distribution Box Outdoor Enclosures Fiber Distribution Box Amphenol s Fiber Demarcation Boxes offer superior protection for indoor or outdoor equipment installations. These sealed polymer enclosures provide a long life,

More information

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology FAAST Fire Alarm Aspirating Sensing Technology The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Confi guration and

More information

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ] ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical

More information

Flame Detection Jon Sarfas

Flame Detection Jon Sarfas Flame Detection Jon Sarfas Agenda Introduction Detection Principles FL4000H MSIR Flame Detector Flame Test Lamp Installation Best Practice Features & Benefits Applications Introduction Primary objectives:

More information

OWNERS MANUAL OPERATION GUIDE

OWNERS MANUAL OPERATION GUIDE OWNERS MANUAL OPERATION GUIDE Built in Redmond Oregon USA www.laserlinemfg.com P/N 1700-0041 REV. 7.24.17 PRODUCT OVERVIEW The GL1700 Laser Guide was designed from the ground up to provide precise start-stop

More information

AccuJet Electrostatic systems

AccuJet Electrostatic systems AccuJet Electrostatic systems Precision sprays for uniform coverage A Sustainable Solution LOW-FLOW, PRECISION MICROSPRAY TECHNOLOGY save TIME, SAVE lubricant, SAVE MONEY Spraying Systems Co., is committed

More information

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL 25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low

More information

2 General Application Photoelectric Sensors

2 General Application Photoelectric Sensors SMARTEYE PRO/PRO 2 General Application Photoelectric Sensors Self-Adjusting General Purpose Sensor www.ttco.com 800-237-0946 2-7 General Application Photoelectric Sensors 2 SMARTEYE PRO/PRO The SMARTEYE

More information

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards v2-5058-co900h Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 1 Agenda 1. Background 2. Related Electrical

More information

Case Study. Selecting fire and gas detectors for harsh and remote locations. INSTRUMENTATION

Case Study. Selecting fire and gas detectors for harsh and remote locations.  INSTRUMENTATION Selecting fire and gas detectors for harsh and remote locations Liquid natural gas (LNG) facilities in Y the frozen Russian Arctic. Drilling platforms in the swells of the North Sea. Pipelines that cross

More information

Dome Fiber Optic Closure SC-221

Dome Fiber Optic Closure SC-221 Dome Fiber Optic Closure SC-221 General Information SC-221 fiber optic closure protects the fiber optic splices from harsh external environment conditions. It is designed for many network segments and

More information

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens Part #: EPLC2-HB-50LED-RT Page: 1 The Larson Electronics EPLC2-HB-50LED-RT Explosion Proof High Bay light

More information

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview Overview Modern combustion (or gas) turbine packages typically include an axial compressor, a combustion section and a turbine. Both compressor and turbine sections consist of one or more sets of fixed

More information

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION Ching-Wei Chen 1, Chia-Ray Chen 1 1 National Space Organization, National Applied Research Laboratories ABSTRACT MWIR (Mid-Wave Infrared) spectroscopy

More information

Recommended Work Area Controls

Recommended Work Area Controls Published on UC Davis Safety Services (https://safetyservices.ucdavis.edu) Safe Laser Practices SafetyNet #: 76 The Principal Investigator is responsible for ensuring that lasers under his/her control

More information

C1N & C2N SERIES Fluid heating for light industrial applications

C1N & C2N SERIES Fluid heating for light industrial applications Keltech Electric Tankless Water Heaters C1N & CN SERIES Fluid heating for light industrial applications Contents Keltech Electric Tankless Water Heaters C1N & CN Series Overview Standard Features 6 Optional

More information

A. This Section includes the following lighting control devices:

A. This Section includes the following lighting control devices: SECTION 26 09 23 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer - 140 - C1D1 - C2D2 - ISO 14644/FS-209E Part #: HALD-24-1X150LED-V2-140DB Page: 1 Made in the USA The HALD-24-1X150LED-V2-140DB from Larson Electronics

More information

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel Fixed Range Fixed Gas Detection Equipment Field mounted gas detection solutions for the protection of plant and personnel Fixed Range The Crowcon Fixed Gas Detector Range When lives and property are at

More information

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV ENERGY PRODUCTS DIVISION LV MV HV Polymeric Reliable protection for power equipment upto 800kV Raychem Polymeric Surge Arrester Safety and reliability are vital in energy industry and Raychem RPG's Energy

More information

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual GG-R REFRIGERANT SENSOR Installation and Operation Manual 2 GG-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

PART V: WORKING WITH LASERS

PART V: WORKING WITH LASERS PART V: WORKING WITH LASERS A. Introduction A laser is a device which when energized, emits visible and/or invisible coherent electromagnetic radiation. This radiation is emitted over a wide range of the

More information

Property risk solutions

Property risk solutions Property risk solutions Inside this issue Welcome to this edition of the Property risk solutions newsletter. This quarterly publication focuses on fixed fire protection and human element safety solutions

More information

SECURITY PRODUCTS CATALOGUE

SECURITY PRODUCTS CATALOGUE I N T E R N A T I O N A L E D I T I O N SECURITY PRODUCTS CATALOGUE Y O U R S E C U R E C H O I C E SWAN TM SERIES SERIES QUAD IMAGING PET IMMUNE DETECTORS QUAD IMAGING TECHNOLOGY WITH PET IMMUNITY The

More information

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES NIJ-0602.02 Standard Compliant Wide Search Area for Faster and Accurate Screening Operations Elegant, Robust and Ergonomic High

More information

Cabinet Cooler Systems

Cabinet Cooler Systems Cooler Systems Cooler Systems Stop electronic control downtime due to heat, dirt, and moisture! maintain NEMA 4, 4X, and 12 integrity. All are and compliant! What is an EXAIR Cooler System? A low cost,

More information

The next generation thermometer from the global leader

The next generation thermometer from the global leader akm oti/wti Remote mount thermometers The next generation thermometer from the global leader Accomplish the most demanding control and alarm configurations Reduce failure costs with reliable AKM bellows

More information

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope 1. Purpose The purpose of the University of Denver Hot Work policy is to protect personnel and property from a fire caused by hot work. The DU Hot Work policy defines the responsibilities and requirements

More information

WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE

WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE AGENDA SCRWA 14 SEPTEMBER 2016 Definition Why EDPM is essential to productivity Fiscal sustainability Why EDPM is essential

More information

How K-Patents DD-23 System is Built to Conform to BLRBAC Recommendations

How K-Patents DD-23 System is Built to Conform to BLRBAC Recommendations PAGE(S) 1 (15) How K-Patents DD-23 System is Built to Conform to BLRBAC Recommendations This document describes how K-Patents Digital Divert Control System DD-23 is built strictly according to the BLRBAC

More information

POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT Compliances: ETL Listed to UL 98 ETL Listed to UL 98A Marine Vessels ETL Listed to CSA C22.2 No..-4 Canada FAA AC /39-2B Heliport Design Guide ICAO Annex 14, Volume II UK CAA CAP 437, Chapter 4, paragraph

More information

THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR

THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR Christian PETIT Anticipation manager Schneider Electric - Network protection and control unit -Marketing

More information

Portable Holiday Detectors

Portable Holiday Detectors COMPLIANT Portable Holiday Detectors Models 780 785 790 Pipeline Inspection Company, Ltd. offers three new "SPY " Model Holiday Detectors that combine the field proven cases, probes and electrode configuration

More information

More Precision. thermometer // Non-contact IR temperature sensors

More Precision. thermometer // Non-contact IR temperature sensors More Precision thermometer // Non-contact IR temperature sensors 48 Compact OEM infrared sensor with external controller thermometer CSmicro thermometer CSmicro Miniature OEM infrared temperature sensor

More information

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET PD20 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET NIJ-0602.02 Compliant Certified according to EU Regulation on Civil Aviation Security NSN: 666515011797 FEATURES NIJ-0602.02 Standard

More information

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series .6 13-355nm and 1.06-3000µm - Pyroelectric Array Camera Pyrocam TM IIIHR & Pyrocam IV Series Features Spectral ranges available from 13 to 355nm and 1.06 to >3000μm Image CO 2 lasers, telecom NIR lasers,

More information

RAMAN SPECTROSCOPY See more, faster than ever before

RAMAN SPECTROSCOPY See more, faster than ever before RAMAN SPECTROSCOPY See more, faster than ever before At Wasatch Photonics we design the kind of Raman spectroscopy products we want to use. As spectroscopists ourselves, we understand the difference that

More information

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology FAAST Fire Alarm Aspirating Sensing Technology The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Configuration and Monitoring

More information

Monitoring of Electrical Equipment Failure Indicators and Alarming

Monitoring of Electrical Equipment Failure Indicators and Alarming Past, Present and Future Maintenance Practices: Monitoring of Electrical Equipment Failure Indicators and Alarming Author: Gabe Paoletti, P.E. Eaton Corporation Senior Member, IEEE gabrieljpaoletti@eaton.com

More information

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved 50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved Part #: EPLC2-TRN-50LED-RT Page: 1 The Larson Electronics EPLC2-TRN-50LED-RT Explosion Proof compact

More information

Desigo Fire Safety intelligent detectors for complete safety

Desigo Fire Safety intelligent detectors for complete safety Desigo Fire Safety intelligent detectors for complete safety Providing coverage from standard to sophisticated applications www.usa.siemens.com/desigo-fire-safety Desigo Fire Safety: innovation based on

More information

PORTASCANNER PORTASCANNER TM ISO TECHNICAL SPECIFICATIONS COLTRACO. for Door Fan & Room Integrity Testing. Ult rasonics since 1987

PORTASCANNER PORTASCANNER TM ISO TECHNICAL SPECIFICATIONS COLTRACO. for Door Fan & Room Integrity Testing. Ult rasonics since 1987 PORTASCANNER PORTASCANNER TM ISO 14520 for Door Fan & Room Integrity Testing TECHNICAL SPECIFICATIONS COLTRACO Ult rasonics since 1987 +44 207 629 8475 info@coltraco.co.uk www.coltraco.com Coltraco Limited,

More information