RELIABLE, CONFIGURABLE PRE-ENGINEERED DOWNHOLE MOTORS
|
|
- Kristina Pitts
- 5 years ago
- Views:
Transcription
1 RELIBLE, CONFIGURBLE PRE-ENGINEERED DOWNHOLE MOTORS Moog DH Series motors help reduce non-productive time (NPT) service costs PRE-ENGINEERED DOWNHOLE BRUSHLESS SERVO MOTORS Reduce your new downhole tool development time, shorten time to market and increase productivity Pre-engineered DH Series Motors allow each customer to develop their highly reliable tooling to stand up to high pressures (,0 bar/,000 PSI) and high temperatures (0 C/ F). Shock and vibration resistant. vailable with optional HPHT stator encapsulation which provides increased motor operating life in downhole applications which are known to have significant contamination. Six pre-engineered motor sizes save you time and engineering costs while providing the flexibility to optimize for your application The Moog modular downhole motor design reduces engineering time and eliminates the associated costs while still providing a configurable product optimized for your application. Each of the six motor sizes is available in multiple stack lengths with windings configured for your input power and output requirements. Use our Pre-engineered Downhole Motors Pre-engineered brushless motors capable of operating in severe duty HPHT downhole service tool environments including temperature, shock, vibration, pressure, fluid filled environments, and more Proven downhole brushless motor technologies with Moog downhole application knowledge, experience and support Faster return on investment (ROI) on your projects with proven and tested designs Motor Size Outside Diameter 9 0 (.0) (.) (.9) (.0) (.) (.) Continuous Output up to up to up to up to up to up to Power 00,0,0,0,0 0,00 Watts Build your own pre-engineered downhole brushless servo motor: Continuous Output Torque BUS Voltage Max. mbient Operating Temperature Feedback Options Temperature Sensor Options WHT MOVES YOUR WORLD
2 TECHNICL DT SIZE 0 Outside Diameter: mm (.0 in) Continuous Output Power: up to 00 watts X 0 [.00] OPTIONL TEMPERTURE SENSOR MOTOR WITHOUT GERBOX X 0 [.00] STTOR LEDS (h) MX X 0 [.00] RESOLVER LED WIRES (OPTIONL) X M X 0.. [.] MIN (MINOR DIMETER) MOTOR WITH GERBOX X 0 [.00] OPTIONL TEMPERTURE SENSOR X 0 [.00] STTOR LEDS [h] MX.0.. X 0 [.00] RESOLVER LED WIRES (OPTIONL) L (h) 0. X M X 0. [.9] (MINOR DIMETER) PDF drawings and performance curves of each motor configuration can also be downloaded from MOTOR STCK DIMENSIONS IN RELTION TO MOTOR PERFORMNCE OPTIONS STCK STGE (.0) (.) (.). (.9) 99 (.9). (.9) 0. (.) (.). (.) GERBOX WITH DIMENSIONS ND PERFORMNCE DT L RTED 0. GER RTIO.,.0.,.,,..,.,.9, 99. RESOLVER ELECTRICL DT ELECTRICL DT 00 HZ INPUT VOLTGE (NOMINL).0 VOLTS RMS MX. INPUT CURRENT m RMS NOMINL INPUT POWER 0.0 WTTS IMPEDNCE Zso 9 +j IMPEDNCE Zro +j IMPEDNCE Zrs +j OUTPUT VOLTGE.0 ±% VOLTS RMS DC ROTOR RESISTNCE. OHMS ±0% DC STTOR RESISTNCE. OHMS ±0% ±0% MV/DEG MX. ERROR FROM E.Z. ±0.0 MINUTES PHSE SHIFT (OPEN CIRCUIT) ± NULL VOLTGE (MX) RMS MILLIVOLTS TRNSFORMTION RTIO.0 ±% lubrication oil at 0,000 PSI (,9 Bar) pressure and up to ambient temperature of C ( F). ll components inside the motor are designed to withstand the 0 C ( F) maximum winding temperature. May 0
3 TECHNICL DT SIZE Outside Diameter: mm (. in) Continuous Output Power: up to,0 watts MOTOR WITHOUT GERBOX X 0 [.00] OPTIONL TEMPERTURE SENSOR X 0 [.00] STTOR LEDS. (KEYED SHFT OPTION)... (KEYED SHFT OPTION) OPTIONL KEY X X LG MX. X 0 [.00] RESOLVER LED WIRES (OPTIONL) (h) X M X 0. [.] MIN (MINOR DIMETER).0 X 0 [.00] OPTIONL TEMPERTURE SENSOR X 0 [.00] STTOR LEDS MOTOR WITH GERBOX.09.. X X [h] MX. X 0 [.00] RESOLVER LED WIRES (OPTIONL) X M X 0. [.] (MINOR DIMETER) -0.0 (h) L PDF drawings and performance curves of each motor configuration can also be downloaded from MOTOR STCK DIMENSIONS IN RELTION TO MOTOR PERFORMNCE OPTIONS STCK. (.) 0.9 (.). (.). (.). (.). (.).9 (9.). (0.) (.). (.). (.) 9. (.). (.) (9.). (0.) 9. (.) RESOLVER ELECTRICL DT ELECTRICL DT 00 HZ INPUT VOLTGE (NOMINL).0 VOLTS RMS MX. INPUT CURRENT. m RMS NOMINL INPUT POWER 0.0 WTTS IMPEDNCE Zso +j99 IMPEDNCE Zro 9 +j9 IMPEDNCE Zrs +j OUTPUT VOLTGE.0 ±% VOLTS RMS DC ROTOR RESISTNCE OHMS ±0% DC STTOR RESISTNCE 9 OHMS ±0% ±0% MV/DEG MX. ERROR FROM E.Z. ±0.0 MINUTES PHSE SHIFT (OPEN CIRCUIT) ± MX NULL VOLTGE (MX) RMS MILLIVOLTS TRNSFORMTION RTIO.0 ±% STGE GERBOX WITH DIMENSIONS ND PERFORMNCE DT L (.9). (.) (.) RTED. GER RTIO.,,.,,, 0,,, 0,,. 9,,, 0, 0, 00, 0,,., 9.9 lubrication oil at 0,000 PSI (,9 Bar) pressure and up to ambient temperature of C ( F). ll components inside the motor are designed to withstand the 0 C ( F) maximum winding temperature. May 0
4 TECHNICL DT Size 9 Outside Diameter: 9 mm (.9 in) Continuous Output Power: up to,0 watts X 0 [.00] OPTIONL TEMPERTURE SENSOR X 0 [.00] STTOR LEDS MOTOR WITHOUT GERBOX OPTIONL KEY X X LG (KEYED SHFT OPTION) MX.9..9 (KEYED SHFT OPTION) X 0 [.00] RESOLVER LED WIRES (OPTIONL) (h).9.00 X M X 0. [.] MIN (MINOR DIMETER).0 X 0 [.00] OPTIONL TEMPERTURE SENSOR MOTOR WITH GERBOX X 0 [.00] STTOR LEDS.09.. X X [h] 9 MX.9.. X M X 0. [.] X 0 [.00] RESOLVER LED WIRES (OPTIONL) L (h) (MINOR DIMETER). PDF drawings and performance curves of each motor configuration can also be downloaded from MOTOR STCK DIMENSIONS IN RELTION TO MOTOR PERFORMNCE OPTIONS STCK 9. (.). (.) 0. (.). (.) 90.9 (.). (.). (9.). (0.) 0. (.). (.). (.) 9. (.).9 (.). (9.). (0.) 9. (.) RESOLVER ELECTRICL DT ELECTRICL DT 00 HZ INPUT VOLTGE (NOMINL).0 VOLTS RMS MX. INPUT CURRENT. m RMS NOMINL INPUT POWER 0.0 WTTS IMPEDNCE Zso +j99 IMPEDNCE Zro 9 +j9 IMPEDNCE Zrs +j OUTPUT VOLTGE.0 ±% VOLTS RMS DC ROTOR RESISTNCE OHMS ±0% DC STTOR RESISTNCE 9 OHMS ±0% ±0% MV/DEG MX. ERROR FROM E.Z. ±0.0 MINUTES PHSE SHIFT (OPEN CIRCUIT) ± MX NULL VOLTGE (MX) RMS MILLIVOLTS TRNSFORMTION RTIO.0 ±% STGE GERBOX WITH DIMENSIONS ND PERFORMNCE DT L (.9). (.) (.) RTED. GER RTIO.,,.,,, 0,,, 0,,. 9,,, 0, 0, 00, 0,,., 9.9 lubrication oil at 0,000 PSI (,9 Bar) pressure and up to ambient temperature of C ( F). ll components inside the motor are designed to withstand the 0 C ( F) maximum winding temperature. May 0
5 TECHNICL DT Size 0 Outside Diameter: mm (.0 in) Continuous Output Power: up to,0 watts X 0 [.00] OPTIONL TEMPERTURE SENSOR X 0 [.00] STTOR LEDS MOTOR WITHOUT GERBOX. (KEYED SHFT OPTION) OPTIONL KEY X X LG...9 (KEYED SHFT OPTION) MX.0.9 X 0 [.00] RESOLVER LED WIRES (OPTIONL) (h) X M X 0. [.] MIN (MINOR DIMETER) MOTOR WITH GERBOX X 0 [.00] OPTIONL TEMPERTURE SENSOR X 0 [.00] STTOR LEDS.. X X MX.0 0. X 0 [.00] RESOLVER LED WIRES (OPTIONL) L (h) X M X 0. [.] (MINOR DIMETER) PDF drawings and performance curves of each motor configuration can also be downloaded from MOTOR STCK DIMENSIONS IN RELTION TO MOTOR PERFORMNCE OPTIONS STCK. (.) 0. (.). (.). (.).9 (.). (.). (9.). (0.). (.9) 0. (.9). (.9) 0. (.9).9 (.9). (9.9). (0.9) 0. (.9) RESOLVER ELECTRICL DT ELECTRICL DT 00 HZ INPUT VOLTGE (NOMINL).0 VOLTS RMS MX. INPUT CURRENT m RMS NOMINL INPUT POWER 0.0 WTTS IMPEDNCE Zso +j OHMS IMPEDNCE Zro +j0 OHMS IMPEDNCE Zrs +j OHMS OUTPUT VOLTGE.0 ±% VOLTS RMS DC ROTOR RESISTNCE. OHMS ±0% DC STTOR RESISTNCE 0. OHMS ±0% ±0% MV/DEG MX. ERROR FROM E.Z. ±0.0 MINUTES PHSE SHIFT (OPEN CIRCUIT) ± MX NOM. DEGREES NULL VOLTGE (MX) RMS MILLIVOLTS TRNSFORMTION RTIO.0 ±% STGE GERBOX WITH DIMENSIONS ND PERFORMNCE DT L. (.9) 0 (.). (.9) RTED 0 GER RTIO,.,..0,,, 0.,, 9,,,.,,, 00, 0,,., 00,,,,. lubrication oil at 0,000 PSI (,9 Bar) pressure and up to ambient temperature of C ( F). ll components inside the motor are designed to withstand the 0 C ( F) maximum winding temperature. May 0
6 TECHNICL DT Size Outside Diameter: 0 mm (. in) Continuous Output Power: up to,0 watts X 0 [.00] OPTIONL TEMPERTURE SENSOR X 0 [.00] STTOR LEDS MOTOR WITHOUT GERBOX..9. (KEYED SHFT OPTION) OPTIONL KEY X X LG..9 (KEYED SHFT OPTION) MX. X 0 [.00] RESOLVER LED WIRES (OPTIONL) (h) X M X 0. [.] MIN (MINOR DIMETER).9 X 0 [.00] OPTIONL TEMPERTURE SENSOR X 0 [.00] STTOR LEDS MOTOR WITH GERBOX.. X X MX. X 0 [.00] RESOLVER LED WIRES (OPTIONL) (h) L X M X 0. [.] (MINOR DIMETER) PDF drawings and performance curves of each motor configuration can also be downloaded from MOTOR STCK DIMENSIONS IN RELTION TO MOTOR PERFORMNCE OPTIONS STCK (.). (.). (.) 9. (.) 9.9 (.) 0. (.). (9.). (0.) 9. (.).9 (.). (.) 9. (.). (.) 0. (.).9 (9.). (0.). (.). (.). (.).9 (.) INPUT VOLTGE (NOMINL) MX. INPUT CURRENT NOMINL INPUT POWER IMPEDNCE Zso IMPEDNCE Zro IMPEDNCE Zrs OUTPUT VOLTGE.0 VOLTS RMS m RMS 0.0 WTTS +j OHMS +j0 OHMS +j OHMS.0 ±% VOLTS RMS DC ROTOR RESISTNCE. OHMS ±0% DC STTOR RESISTNCE 0. OHMS ±0% RESOLVER ELECTRICL DT ELECTRICL DT 00 HZ MX. ERROR FROM E.Z. PHSE SHIFT (OPEN CIRCUIT) NULL VOLTGE (MX) RMS ±0% MV/DEG ±0.0 MINUTES ± MX NOM. DEGREES MILLIVOLTS TRNSFORMTION RTIO.0 ±% STGE GERBOX WITH DIMENSIONS ND PERFORMNCE DT L. (.9) 0 (.). (.9) RTED 0 GER RTIO,.,..0,,, 0.,, 9,,,.,,, 00, 0,,., 00,,,,. lubrication oil at 0,000 PSI (,9 Bar) pressure and up to ambient temperature of C ( F). ll components inside the motor are designed to withstand the 0 C ( F) maximum winding temperature. May 0
7 TECHNICL DT Size Outside Diameter: mm (. in) Continuous Output Power: up to 0,00 watts X 0 [.00] OPTIONL TEMPERTURE SENSOR X 0 [.00] STTOR LEDS MOTOR WITHOUT GERBOX..9 (KEYED SHFT OPTION) OPTIONL KEY X X 0 LG.9. (KEYED SHFT OPTION) MX X 0 [.00] RESOLVER LED WIRES (OPTIONL) (h) X M X 0. 9 [.] MIN (MINOR DIMETER).90 MOTOR WITH GERBOX X 0 [.00] OPTIONL TEMPERTURE SENSOR X 0 [.00] STTOR LEDS.. X X MX X 0 [.00] RESOLVER LED WIRES (OPTIONL) L (h) X M X 0. 9 [.] (MINOR DIMETER).0 PDF drawings and performance curves of each motor configuration can also be downloaded from MOTOR STCK DIMENSIONS IN RELTION TO MOTOR PERFORMNCE OPTIONS STCK (.9). (.9) (.9). (.9) 0. (.9). (.9). (9.9) (0.9) 0. (.9). (.9). (.) 0. (.) (.). (.). (9.). (0.). (.) (.). (.). (.) RESOLVER ELECTRICL DT ELECTRICL DT 00 HZ INPUT VOLTGE (NOMINL).0 VOLTS RMS MX. INPUT CURRENT m RMS NOMINL INPUT POWER 0.0 WTTS IMPEDNCE Zso +j OHMS IMPEDNCE Zro +j0 OHMS IMPEDNCE Zrs +j OHMS OUTPUT VOLTGE.0 ±% VOLTS RMS DC ROTOR RESISTNCE. OHMS ±0% DC STTOR RESISTNCE 0. OHMS ±0% ±0% MV/DEG MX. ERROR FROM E.Z. ±0.0 MINUTES PHSE SHIFT (OPEN CIRCUIT) ± MX NOM. DEGREES NULL VOLTGE (MX) RMS MILLIVOLTS TRNSFORMTION RTIO.0 ±% STGE GERBOX WITH DIMENSIONS ND PERFORMNCE DT L 0 (.) (.00) 9 (.9) RTED 0 GER RTIO,,,.,,, 0,, 0, 0.,. 9,,, 0, 0, 00, 0,,,., 9.9 lubrication oil at 0,000 PSI (,9 Bar) pressure and up to ambient temperature of C ( F). ll components inside the motor are designed to withstand the 0 C ( F) maximum winding temperature. May 0
8 TECHNICL DT BUILD THE PRE-ENGINEERED DOWNHOLE BRUSHLESS SERVO MOTOR THT WILL FIT YOUR PPLICTION Follow a quick and simple self guided web tool and configure your pre-engineered downhole motor! Brushless Servo Motors OPTIONS WIRING DIGRM POWER CONNECTION Pre-engineered motors are based on a standard BUS voltage of Vrms; other options available Feedback options: Sensorless -Pole Resolver Temperature Sensor options: RTD 000 Ω None Encapsulation available to increase motor robustness in highly contaminated downhole tool environments Key downhole environmental capabilities include temperature, shock, vibration, pressure, fluid filled environments, stainless steel construction B C SIN- SIN+ COS+ COS- REF+ REF- GREY GREEN BLCK WHITE RED SIGNL CONNECTION OPTIONL BLUE YELLOW RED BLCK RED/WHT YEL/WHT 000 OHM RTD SENSOR (OPTIONL) RESOLVER H RESOLVER PHSING EQUTION E(S-S)=K E(R-R)COS E(S-S)=K E(R-R)SIN FOR CCW ROTTION VIEWING THE OUTPUT SHFT phone: info.usa@moog.com Moog has offices around the world. For more information or the office nearest you, contact us online. Moog is a registered trademark of Moog, Inc. and its subsidiaries. ll trademarks as indicated herein are the property of Moog, Inc. and its subsidiaries. 0 Moog, Inc. ll rights reserved. ll changes are reserved. Pre-Engineered Downhole Brushless Servo Motors TJW/Rev. - May 0, Id. CDL0-en This technical data is based on current available information and is subject to change at any time by Moog. Specifications for specific systems or applications may vary.
DOWNHOLE SOLUTIONS. MOTION CONTROL SOluTIONS TAILORED TO YOUR CRITICAL DOWNHOLE APPLICATIONS WHAT MOVES YOUR WORLD. Rev.
DOWNHOLE SOLUTIONS Rev.-, May 2013 MOTION CONTROL SOluTIONS TAILORED TO YOUR CRITICAL DOWNHOLE APPLICATIONS WHAT MOVES YOUR WORLD IMPROVE PERFORMANCE FOR YOUR DOWNHOLE TOOLS To succeed today, oil and gas
More information70XXA-1 series. Voltage. Features. Applications. Description. Order Information. Designator Symbol Description 1 2 Integer Output Voltage(2.2~7.
Fetures Low power consumption Low temperture coefficient Builtin hysteresis chrcteristic High input voltge (up to 24) Output voltge ccurcy: tolernce ±2% TO92, SOT89 nd SOT23 pckge Applictions Bttery checkers
More informationSCREWPLUG HEATERS. immersion heaters
SCREWPLUG HETERS SCREWPLUG HETERS OVERVIEW WTTCO screwplug heaters are comprised of hairpin tubular elements that are brazed or welded into a machined pipe thread fitting, which are then screwed directly
More informationInteractive Catalog Replaces Catalog Pages
Interactive Replaces Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive. The Interactive is a power search tool that makes it easier to find product information.
More informationInteractive Catalog Replaces Catalog Pages
Interactive Replaces Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive. The Interactive is a power search tool that makes it easier to find product information.
More informationSUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD1212PTS1-6A
SUNON SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 120X120X25 mm M O D E L : KD1212PTS1-6A P/N : APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D120015 DAWN. Hua
More informationM7100 Pressure Transducer
SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces
More informationKILOVAC K1K High-Voltage Contactor
KILOVAC K1K High-Voltage Contactor High Performance in a Compact, Lightweight, Hermetically Sealed Contactor Designed for up to 1000 V/1000 A in Harsh Environments KILOVAC K1K High-Voltage Contactor Compact,
More informationScrewplug Heaters. Type CX. Screwplug Heaters Type CX. Operation. Application. Selection. Terminal Block Simplifies Wiring. Warning - Fire Hazard
Screwplug Heaters Screwplug Heaters pplication Screwplug heaters are primarily used to heat liquids in tanks or vessels. To do so safely and reliably requires that the heating elements remain fully immersed
More informationJun08 Rev A
Product Specification Terminal Block Crimp Snap Plug Assembly 108-2319 09Jun08 Rev A 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics
More informationRoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES
KEY FEATURES Hermetically sealed intrinsically safe. Operates in explosive/harsh environments without oxidation or contamination of contacts, including long periods of non-operation 8kV isolation between
More informationProduct Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140
CBL LOW-BOY OIL FURNCE INPUT RTES: 70,000 thru 154,000 BTUH SERIES 140 Product Data THE LTEST IN OIL FURNCE TECHNOLOGY 96280 The model CBL combines high efficiency and quiet operation with oil heating
More informationTEMPORARY SPECIFICATION FOR REFERENCE
TEMPORARY SPECIFICATION FOR REFERENCE Customer : Description : EST FAN (Energy Saving Technology Fan) Customer Part No. REV. : Delta Model No. AFL12AUHE-00 REV. : 02 Sample Issue No. : Sample Issue Date
More informationDP86 Constant Voltage with Fitting
SPECIFICATIONS 316L SS Wet/Wet Differential Low Pressure 0 100mV Output The DP86 constant voltage with fitting differential pressure sensor is a double-sided, media compatible, piezoresistive silicon pressure
More informationSmoke control dampers
X X testregistrierung Smoke control dmpers Type with BLE- ctutor CE complint ccording to Europen regultions For mechnicl smoke extrct systems nd s n dditionl supply ir inlet Rectngulr smoke control dmpers
More information2-Stage 4 K Closed Cycle Refrigerator Systems
CRYO 2-Stage 4 K Closed Cycle Refrigerator Systems Variable Temperature Closed Cycle Refrigerator Systems Cryo Industries manufactures closed cycle cryogenic workstations for a large variety of experimental
More informationunico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113
tu 137 IR COOLED Liquid chiller equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel CONDENSING coils 280 1500 kw Energy Class More efficient
More informationSTATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP
STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP PUMP Grinder Pumps KPCG-21 1HP Dual Seal, High Performance Progressive Cavity Grinder Pump,
More informationORDERING INFORMATION NO = DIM = NOTES. Contact factory for 347V WIRELESS DMX COMPONENTS REQUIRED FOR WRCN EXTERIOR - LEADER CABLES
SHPING THE EXPERIENCE OF LIGHT PTENT PENDING FCDE & FLOOD LIGHTING WHITE LIGHT, STTIC RED, BLUE, GREEN, MBER Line voltage LED, High Performance Facade and Flood Lighting Ideal for lighting facades, structures,
More informationM5200 Industrial Pressure Transducer
SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound
More informationINSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch
INSTRUCTION MANUAL MM-615E 246717 Series FS1 High Sensitivity Liquid Flow Switch SPECIFICATIONS Maximum Liquid Pressure: 100 psi 7 kg/cm 2 ) Liquid Temperature Range TL): 32-225 F 0-107 C) Ambient Temperature
More informationCOMPLETE WATER SOURCE HEAT PUMPS CATALOG
EZ Series 8S EZ Series 81 EZ Series WM COMPLETE WTER SOURCE HET PUMPS CTLOG EZ Series LM EZ Series EH EZ Series WC ll products are now using Environmentally Friendly HCFC and CFC FREE Refrigerants. 6140284
More informationER52 - Evaporator Controller
ER52 - Evaporator Controller Electronic Refrigeration Line Product Bulletin Devices are standalone digital controller for static or ventilated refrigeration units working at positive temperatures. They
More informationApplication guide ECOLEAN - EAC/EAR. Providing indoor climate comfort
pplication guide ECOLEN - EC/ER Providing indoor climate comfort MSLE-00 2-200 CONTENTS CONTENTS Introduction and description of the components... 2 vailable options... Performance tables for the units
More informationSchneider Electric Erie T155 Series
Schneider Electric Erie T Series Non-Digital, On/Off Thermostat General Instructions Application The T series thermostat provides on/off control for low voltage and line voltage valves, relays and fan
More informationU5300 Industrial Pressure Transducer
FEATURES Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output ±0.1% Accuracy ±0.5% Total Error Band Compact Outline -40 C to +125 C
More informationINSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch
INSTRUCTION MANUAL MM-601REVI 246796 Series FS4-3 General Purpose Liquid Flow Switch SPECIFICATIONS Maximum Liquid Pressure: 160 psi (11.3 kg/cm 2 ) Liquid Temperature Range (TL): 32-300 F (0-149 C) Ambient
More informationD5100 Industrial Differential Pressure Transducer
FEATURES Heavy Industrial CE Approval (amplified only) As Low As ±0.1% Pressure Non Linearity Rugged Construction: Can Withstand 50g Shock/20g Vibration Up to -40 C to +125 C Operating Temperature Range
More informationU5700 Submersible Liquid Level Pressure Transducer
SPECIFICATIONS High Accuracy CE Compliant and Waterproof UL Certified Variety of Pressure Port Configurations Waterproof Optional Stainless Steel Snubber IP68 Rated Connection and Submersible Polyurethane
More informationOPERATION SERVICE AND INSTALLATION MANUAL
OPERTION SERVICE ND INSTLLTION MNUL DUCTIR Congratulations you have made a wise choice with the purchase of your Lennox are conditioning set This product has been designed, assembled and supplied in one
More informationAC Backward Curved Motorized Impellers
AC Backward Curved Motorized Impellers 135 ebm's Backward Curved Motorized Impellers save space and outperform conventional fans and blowers These backward curved motorized impellers provide efficient
More information2-Stage 4 K Closed Cycle Refrigerator Systems
2-Stage 4 K Closed Cycle Refrigerator Systems Variable Temperature Closed Cycle Refrigerator Systems Cryo Industries manufactures closed cycle cryogenic workstations for a large variety of experimental
More informationPRPHP16 PRODUCT SPECIFICATIONS PRP HP P A TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER MINOR REVISION SEQUENCE A = 1ST GENERATION
PRPHP6 PRODUCT SPECIFICTIONS TWO STGE COMPRESSOR VRIBLE SPEED BLOWER FORM NO. PRPHP6-00 (08/207) MODEL NUMBER PRP HP 6 36 P - - PRODUCT TYPE PRP = PREMIUM RESIDENTIL PCKGED UNIT TYPE HP = HET PUMP NOMINL
More informationCOTES ALL-ROUND THE C35 RANGE
EPERTS IN HUMIDITY MNGEMENT COTES.COM DEHUMIDIFICTION THE WY YOU WNT IT C35 DEHUMIDIFIER IDEL FOR USE IN > PHRMCEUTICL PRODUCTION FCILITIES > FOOD INDUSTRY PROCESSING FCILITIES > COLD STORES/FREEZER FCILITIES
More informationENERVEX MDF MODULATING DAMPER
ENERVEX MDF MODULATING DAMPER 3903007 05.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! UL File E467733 ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238
More informationMEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications
MEAS 5700 Subermsible Liquid Level Pressure Transducer Features Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output ±0.25% Accuracy
More informationCOMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS
COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.895 Date: march 8, 014 Supersedes: 10.895 Date: december 10, 013 1.0 Symbols used in this document 1.0
More informationMiniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet
Miniature Low Pressure Flow-Through Sensors 26PC Series, Compensated/Unamplified 1 psi to 100 psi Datasheet Miniature Low Pressure Flow-Through Sensors The 26PC Series Miniature Low Pressure Flow-Through
More informationThermoStar Refrigeration Air Dryers
ThermoStar Refrigeration Air Dryers Why Dry Compressed Air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapor and airborne particles. These problems
More informationGLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning
: Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL
More informationProven Friction Reduction, Improved Weight Transfer. Agitator Systems
Agitator Systems Proven Friction Reduction, Improved Weight Transfer Agitator Systems The compression and friction forces that affect your drillstring downhole limit weight-on bit, reduce ROP, and can
More informationRing Detect Relays. Model RDR. Installation & Operation. Ph: \ \
Ring Detect Relays Installation & Operation P005116 Rev. E 180803 8/3/2018 11:19 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents... 2 Models
More informationTitle Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications
Title Page Report Title: Downhole Power Generation and Wireless Communications for Intelligent Completions Applications Type of Report: Quarterly Progress Report Project Report Period: Start Date April
More informationunico pf unico pf rcgroupairconditioning
: ckaged air cooled liquid chillers for indoor installation, equipped with scroll compressors and plug fan Cooling Capacity: 19,6 264 unico pf PLTE rcgroupairconditioning R410 E C MIN FETURES ir cooled
More informationFire dampers. Type FKA-3.8. For diverse applications
. X X testregistrierung Fire dmpers Type with fusible link for 7 C or 95 C For diverse pplictions Rectngulr fire dmper for the isoltion of duct penetrtions between fire comprtments, for mortr-bsed instlltion
More informationFire dampers. Type FKA-EU. For diverse applications
. X X testregistrierung Fire dmpers Type with fusible link for 72 C CE complint ccording to Europen regultions For diverse pplictions Rectngulr fire dmper for the isoltion of duct penetrtions between two
More informationApproved by: Document no.: EGT
ET Page 1 of 6 TECHNICL MNUL EXPLOSION PROOF MNUL CLL POINT / PUSH BUTTON TEX Marking: Code: II 2D EPL b, Db Ex d IIC T6 IP66 Ex tb IIIC T85 C Marking details: Please note that every care has been taken
More informationML 1 80 UH 070 X E 36 B
PRODUCT SPECIFICTIONS GS FURNCES ML80UHE MERIT SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 2063 ugust 202 Supersedes January 202 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal
More informationXUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m
Characteristics photo-electric sensor - XUB - thru beam - laser - Sn 100m - 12..24VDC - cable 2m Buy online Complementary Enclosure material Lens material Blind zone Output type Status LED [Us] rated supply
More informationLOW PRESSURE Intrinsically Safe Transducer AST44LP
Intrinsically Safe Transducer AST44LP Overview The AST44LP is a stainless steel pressure transducer with a wide variety of options. With its rugged construction and the best price-toperformance ratio in
More informationBetter Design, Better Control, Better Systems.
Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning
More informationDEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option
Description of options Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M 4189340401D SW 1.4X.X Description of option Functional description DEIF A/S Parameter list DEIF A/S,
More informationD5100 Industrial Differential Pressure Transducer
SPECIFICATIONS 316L Stainless Steel Wetted Surface Voltage, Current, and mv Outputs True Wet/Wet Differential CE Certified (amplified version only) Variety of Pressure Ports and Electrical Connections
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit
ABB MEASUREMENT & ANALYTICS DATA SHEET C50 1/16 DIN controller / alarm unit 2 C50 1/16 DI N CON TROLL ER / AL ARM U NIT DS/C 50-E N RE V. M Measurement made easy C50 the 1/16 DIN controller to suit your
More informationWARNING MISUSE OF DOCUMENTATION
FEATURES Mass flow and differential pressure versions Bi-directional sensing capability Highly stable null and full-scale Extremely low pressure drop Compact package design Extremely low hysteresis and
More informationELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor
PRODUCT SPECIFICTIONS GS FURNCES EL80UHE ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 20660 February 208 Supersedes January 208 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal
More informationWilo Stratos Variable Speed Inline Pumps. Engineering Specification
Wilo Stratos Variable Speed Inline Pumps Engineering Specification PART 1 - GENERAL 1.1 WORKED INCLUDED A. Furnish and install circulating pumps consistent with the hydronic system s performance, requirements
More informationCOMPLETE WATER SOURCE HEAT PUMPS CATALOG
EZ Series 8S EZ Series 81 EZ Series WM COMPLETE WTER SOURCE HET PUMPS CTLOG EZ Series LM EZ Series EH EZ Series WC ll products are now using Environmentally Friendly HCFC and CFC FREE Refrigerants. 6140284
More informationES-6. Encapsulated Rotary Screw Air Compressors. 4 7 kw 5 10 hp
ES-6 Encapsulated Rotary Screw Air Compressors 4 7 kw 5 10 hp About Sullair For more than 50 years, Sullair has been on the leading edge of compressed air solutions. We were one of the first to execute
More informationSPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL Customer : STD Description : DC FAN Customer Part No. REV. : Delta Model No. : REV. : 00C Sample Issue No. : Sample Issue Date : 2017/7/7 PLEASE SEND ONE COPY OF THIS SPECIFICAITON
More informationINTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400
Pressure Transducer / Transmitter AST4400 Overview The AST4400 is a stainless steel pressure transducer with a wide variety of options. With its rugged construction and best price-toperformance ratio in
More informationpyxis pyxisa NEW rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning
More informationNEXT DL NEXT DL. rcgroupairconditioning
NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning
More informationHeating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler
WTER HETING / OILERS CWMV PRODUCT SPECIFICTIONS Residential Hot Water Heat ir Handler ulletin No. 0434 ugust 05 Supersedes June 04 Heating Capacity - 3,700 to 0,000 tuh Nominal dd-on Cooling - to 5 Tons
More informationis the Solution to Your Portable Compressor Moisture Problems. Get Dry Air.
Get Dry Air. Solution is the to Your Portable Compressor Moisture Problems. DryAir works by effectively removing harmful moisture from the discharge air of portable gas and diesel compressors. DryAir units
More informationunico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning
: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel
More informationKGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.
Grinder Pumps KGP(X) 7.5-15HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) (PENDING) The KEEN PUMP KGP(X) series centrifugal grinder pumps are designed for municipal, commercial
More informationMERIT SERIES Up Flow / Horizontal
G S F U R N C E S G40UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D T Bulletin No. 210278 December 2008 Supersedes May 2007 FUE 80% Input 44,000 to 154,000 Btuh Nominal dd on Cooling 1.5
More informationNEW Lowara ecocirc PRO The new high efficiency domestic hot water PumPs with automatic air venting function and TheRmaL insulation shell
NEW Lowara ecocirc PRO The new high efficiency domestic hot water pumps with automatic air venting function and thermal insulation shell ecocirc PRO domestic hot water circulation pumps. Areas of use.
More informationCeiling Mount Temperature Sensor
AB-5272 Specifications/Instructions Ceiling Mount Temperature Sensor General Ceiling Mount Temperature Sensor Model TY7301 is a temperature sensor designed to be used with electronic controllers. This
More informationMODEL NUMBER: SRCOOL60KCW
The SRCOOL60KCW is not a standalone unit. It must connect to an existing building chilled water system to operate. SmartRack 60 kw 208 230V 50/60 Hz In-Row Precision Cooler, Chilled Water Type MODEL NUMBER:
More informationPYXIS U PYXIS U. rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES
More informationService Manual. Panasonic
Pnsonic PEG2070E Version:702 Service Mnul Humidifying Air Purifier HongKong/Mongoli Mrket WARNING This service informtion is designed for experienced repir technicins only nd is not designed for use by
More informationSTT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009
STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full
More informationTwo Circuit Heavy Duty Burner Connector
Product 108-1056 11 Oct.16 Rev B Specification EC 0990-0059-05 Two Circuit Heavy Duty Burner Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the
More informationED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS
ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS Analog voltage or current output Low profile IP52 sealing Sleeve or ball bearing Excellent stability no optic degradation The ED-18 Series Magnetic
More informationInstallation Instructions NEMA-3R Cover Kit for D1h D2h VLT FC Series FC 102, FC 103, FC 202, and FC Description. 1.
1.1 Description The NEMA 3R cover kit is designed for D1h and D2h enclosure sizes for the following applications: VLT HVAC Drive FC 102 VLT Refrigeration Drive FC 103 VLT AQUA Drive FC 202 VLT AutomationDrive
More informationGREEN REFRIGERANT R-410A
PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered
More informationCartridge Heaters. Components. Application Guidelines
Application Guidelines Up to 1.297" Dia. Up to 60" Lengths Up to 11,500 Watts 120 and 240 Volt Up to 1400 F Max. Working Temp. Modification Available to Fit Custom Applications Type CIR cartridge heaters
More informationHydraulic rock drill
Hydraulic rock drill We ll follow you all the way Rock drilling is a tough job. And it gets ever more demanding. We want to make your job easier as you go deeper. Your job is an inspiration to us. By understanding
More informationpyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning
Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876
More informationHAL Hercules Horizontal Pumping System STRONG. VERSATILE. EFFICIENT.
HAL122140 Hercules Horizontal Pumping System STRONG. VERSATILE. EFFICIENT. Hercules Horizontal Pumping System VERSATILE HORIZONTAL SURFACE PUMPING SYSTEM FOR CONVENTIONAL OR UNCONVENTIONAL PLAYS Summit
More informationThermopile Sensor TPS 230 / 3365
Revision - Date: 2007/11/12 SENSOR SOLUTIONS Introduction PerkinElmer introduces the new TPS 230 as part of the TPS 23x family for low-cost remote temperature measurement applications. It consists of a
More informationglider evo cla glider evo cla A-CLASS rcgroupairconditioning
Industrial GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 284 1513 -CLSS rcgroupairconditioning
More informationAPPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation
OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature
More informationMR3CCUHV Temperature/Defrost Control
Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 0401 MR3CCUHV Temperature/Defrost Control The MR3CCUHV Temperature/Defrost Control is designed to control the temperature
More informationGREEN REFRIGERANT R-410A
THE WLL-MOUNT IR CONDITIONERS -. EER, (HZ) Models W7 to W. to Ton (, to, Btuh) Right Side Control Panel Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed
More informationABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications
BH BSIN HETER CONTROLS PCKGE engineering data and specifications BH Basin Heater Control Package 2 BH DVNCED BSIN HETER CONTROLS The Marley BH basin heater package controls the ON and OFF operation of
More informationWilo IL Vertical Split-Coupled Inline Pumps
Wilo IL Vertical Split-Coupled Inline Pumps Vertical Inline Split-Coupled, Single Stage Pumps March, 2013 Marcos D. Roimicher, Product Manager BS Market Segment, Product Management Department 120-08-002-0313
More informationSTANDARD. Customer : DC FAN. Description : Customer P/N : rev. : N/A X01. Sample issue date : DEC Quantity :
Delta Electronics, Inc. No.252, Shanying Rd., Guishan Dist., TEL : 886-(0)3-3591968 Taoyuan City 333, Taiwan (R.O.C.) FAX : 886-(0)3-3591991 Specification For Reference Customer : Description : STANDARD
More informationSF 228T TWO-WAY SOUNDFIELD CEILING TILE SPEAKERS WITH 8" WOOFER AND 70/100 V TRANSFORMER SPEAKERS
SPEAKERS SF 228T TWO-WAY SOUNDFIELD CEILING TILE SPEAKERS WITH 8" WOOFER AND 7/1 V TRANSFORMER 2' x 2' (61 cm x 61 cm), 18.5 lb (8.4 kg) drop-in ceiling tile speaker for US style suspended ceilings UL
More informationUnderstanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration
Understanding Head Pressure Control Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration WE WILL LOOK AT: 1. Why We Need Head Pressure Control? 2. How Do We Control Head Pressure - Methods?
More informationSPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL Customer : STD Description : DC FAN Customer Part No. REV. : Delta Model No. : REV. : 01 Sample Issue No. : Sample Issue Date : AUG.14 2017 PLEASE SEND ONE COPY OF THIS SPECIFICAITON
More informationModel Q45P/R. ph/orp Monitor...
Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.
More informationAD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)
AD0412HB-C71GP DC FAN (RoHS) P.S. REV. (P) A Y D A T A - S H E E T Engineering Printed On: 11/07/18 BRUSHLESS AXIAL COOLING FANS Customer Ref: (RoHS) Adda Model No AD0412HB-C71GP P.S: (P) Samples attached
More informationCAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS
Domestic Washer Technical Information 120 V, 60 Hz Models SAV2555AW* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.
More informationUH Series Horizontal Fan Forced Unit Heater
UH Series Horizontal Fan Forced Unit Heater 3.3 KW THROUGH 48 KW HORIZONTL DISCHRGE SUSPENDED FN FORCED UNIT HETERS VILLE IN 1 OR 3 PHSE FOR LL STNDRD VOLTGES FROM 8V TO 480V. Manufactured in U.S.. NOTE:
More informationAFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE
PRODUCT SPECIFICTIONS GS FURNCES ML80UHE MERIT SERIES Upflow / Horizontal - High Efficiency lower Motor ulletin No. 20825 July 208 Supersedes February 208 FUE - 80% Input - 44,000 to 32,000 tuh Nominal
More informationENCLOSURE AIR CONDITIONERS
ENCLOSURE IR CONDITIONERS Compact Series 2,000 BTUH Celebrating 20 Years of Excellence Engineered & manufactured to endure the most difficult of environments and applications. ISC air conditioners will
More informationSpecifications. STEALTH Simplex, Wall Mount For SGV, OGP & OGV Grinder Pumps Control Panels & Accessories.
Specifications STELTH Simplex, Wall Mount For, OGP & OGV Grinder Pumps Control Panels & ccessories GENERL: wall mounted control panel shall be supplied with each station. ll control panels shall be UL
More information