1 BIRKET Specialty Lighting LED BRIK User s Guide November 11, 2009

2 Purpose The purpose of this document is to provide an overview of the LED BRIK Strobe System by Birket Specialty Lighting. This document is meant to be a quick start guide, which means that the following information will help you understand only the most commonly used features of the system. System Overview The LED BRIK Strobe System controls up to 16 channels of high powered LED strobes. Each of the 16 channels is configurable for the current supplied to the attached LED(s) on the channel. The LED BRIK Strobe System can be operated in standalone mode using patterns built into the firmware or via DMX 512 connection. Each LED BRIK Strobe System is made up of the following major components: Enclosure stainless steel (NEMA 4x) or painted metal (NEMA 12) Industrial power supply 120/220VAC to 24V DC Brain2000 DMX control board assembly with firmware (revision F05) High Powered LED Brawn Board (HPLBB) for controlling LEDs from 350 to 1500 ma LED Strobes quantity and style varies based on project requirements

3 System Setup (prior to applying power) As mentioned previously, each of the 16 LED BRIK Strobe channels can be set up for a specific current setting. The current settings that are available include 350mA, 700mA, 1000mA, and 1500mA. Each LED channel on the HPLBB has a T shaped header to which a jumper may be connected and the LED current set. Your HPLBB may have been set up at the factory prior to shipping, but it is recommended that you double check all settings before power up. CAUTION LEDs will be damaged if connected to a channel with higher current setting. Understand the current requirements of each of your LEDs and set the jumper to the proper current. For example: do not connect a 350 ma LED to a channel set for 1500 ma. Please refer to the CH. LED Current Setting key printed on the PCB to set each channel. Please use the following current setting for LEDs provided by Birket. If you are using your own LEDs, please understand the forward current requirements of your LEDs. SB 010 XXX Uses Luxeon Rebel LEDs set for 700 ma SB 020 XXX Uses LedEngin LEDs set for 1000 ma SB 021 XXX Uses LedEngin LEDs set for 1500 ma SB 022 XXX Uses LedEngin LEDs set for 1000 ma FIRE Starter 1.0 Uses Luxeon Rebel LEDs set for 700 ma FIRE Cube Uses Luxeon Rebel LEDs set for 700 ma Beyond the jumpers, you should also verify all terminations have been made correctly with the proper polarity. The polarity of the connectors is labeled clearly on each of the HPLBB channels.

4 System Power On Each LED BRIK Strobe System ships from Birket Specialty Lighting with the customer requested power cord type. The LED BRIK power supply will properly detect 120V AC or 220V AC there are no settings to adjust to match your AC at the LED BRIK Strobe System install location. To power the system you will have to first plug in the AC power cord to your source of power. Next you will need to open the lid of the LED BRIK Enclosure and confirm that the LED power indicator on the industrial power supply is lit. If the indicator is not lit, make sure your source of power is active. Next you will need to turn on the low voltage to the circuit board assemblies. The industrial power supply outputs 24V DC, which is fed through an on/off switch and then to the circuit board assemblies. To turn on or off the LED BRIK Strobe System you will need to turn the on/off switch to the desired position. Once you turn the on/off switch to the on position ( ) you will see several LEDs begin to glow on the circuit board assemblies and you will also see data indicated on the 7 segment LED indicators.

5 When the system is turned on, the following will happen: On the Brain2000 the +5.0V LED will glow (near the power connector at the top of the PCB) On the Brain2000 the +3.3V LED will glow (near the power connector at the top of the PCB) On the Brain2000 the 7 segment display will indicate the firmware revision number briefly in the format of Fxx.x where xx.x is the revision number. After the firmware revision is displayed the 7 segment display will change to display the mode the device was last in before it powered down. On the HPLBB the VLED will glow (near the fuse and J2 expansion connector) On the HPLBB the +5.0V LED will glow (near the J2 expansion connector) On the HPLBB the +3.3V LED will glow (near the J2 expansion connector) All LEDs will be simultaneously energized to the current setting of the jumper

6 User Interface The Brain2000 hosts a set of 7 segment LED displays for showing text and numbers. Furthermore there are three horizontally aligned buttons underneath the display for navigating the modes as well as decreasing or increasing values. In addition there are two LEDs located to the right of the 7 segment display; these LEDs are labeled STATUS and ACTIVITY. The user interface is segmented into screens. Inside each screen values can be adjusted. Pressing the center button (S2) will change from one screen to the next. Pressing the button on the left (S1) will decrease values while pressing the button the right (S3) will increase values. The following table explains each screen further. SCREEN Firmware Display DMX 512A Address SCREEN DESCRIPTION 7 Segment Display: Fxx.x where xx.x is the firmware revision. This screen is only displayed for a moment when the system is first started. 7 Segment Display: Axxx where xxx is the DMX 512A starting address/slot. The decrement/increment buttons will change the address to be lower or higher. Holding down the button will cause the address to change faster. The DMX 512A Address will automatically be saved as you scroll through the addresses. While in this mode any DMX 512A packets will be processed and the LED BRIK Strobes will behave according to the set DMX 512A Mode. Pattern Selection Pressing the center button will change from this screen to Pattern Selection Screen. 7 Segment Display: Pxxx where xxx is the pattern number. The decrement/increment buttons will change the pattern to be lower or higher.

7 The pattern being displayed will automatically be saved and recalled when you return to the Pattern Selection Screen. While in this mode the patterns are displayed on the LED BRIK Strobes. DMX 512A Mode Pressing the center button will change from this screen to the DMX 512A Mode Screen. 7 Segment Display: nnxx where xx is the mode number. The decrement/increment buttons will change the mode to be lower or higher. The DMX 512A Mode will automatically be saved as you scroll through the modes. While in this mode any DMX 512A packets will be processed and the LED BRIK Strobes will behave according to the set DMX 512A Mode. Pressing the center button will change from this screen to the DMX 512A Address Screen. System Control The LED BRIK Strobe System can be controlled via DMX 512A or it can run stand alone using built in patterns. The LED BRIK Strobe System stores the last mode of operation it was in before power down. In addition the system will store any user set parameters such as DMX address or pattern settings. For instance, if the system is set to Pattern 1 (P 1 on the 7 segment display) and the system was powered off, next time the system is turned on it will return to this setting. DMX Control The LED BRIK Strobe System accepts a DMX 512A signal via the RJ 45 connectors on the Brain2000 printed circuit board assembly. There are two connectors, one is for DMX 512A input and the other is for DMX 512A thru (daisy chain to the next DMX 512A device). The wiring for these connectors follows the ESTA Standards for DMX 512A. WARNING: DO NOT CONNECT THE RJ 45 CONNECTORS ON THE BRAIN2000 TO ETHERNET EQUIPMENT. MAKING SUCH A CONNECTION MAY DESTROY THE BRAIN2000 AND THE CONNECTED ETHERNET DEVICE.

8 NOTE: As of this writing the DMX 512A firmware has not been fully tested with Remote Device Management (RDM). The LED BRIK Strobe System doesn t respond to RDM, but may behave inappropriately on networks with RDM data. There is an on going effort to revise the firmware. If you are using RDM on a network with the LED BRIK Strobe System and are experiencing problems, please contact us. When a DMX 512A source is connected to the LED BRIK Strobe System and the LED BRIK Strobe System is successfully receiving the data packets you will see the Activity LED flicker or glow. The LED BRIK Strobe System requires one or two DMX slots per LED Channel based on the mode selected. Thus a system using the LED BRIK Strobe system will require 16 or 32 DMX slots per LED BRIK Strobe System controller. Our LED BRIK does not have XLR connectors. If your system requires the use of XLR connectors for the DMX connections, adapters are available to convert the connectors without having to re wire.

9 DMX Control The LED BRIK Strobe System has three modes which are as follows: MODE SLOTS REQUIRED MODE DESCRIPTION 0 1 per channel Strobe with Variable Intensity: Uses the DMX value to set the flash intensity. Set the DMX value to the desired level Drop the value to 0 to flash the light Repeat as desired for multiple flashes 0 = OFF 1 = the least intensity 255 = the highest intensity. 1 1 per channel Strobe with Variable Rate (at maximum intensity): Uses the DMX value to set the flashing rate. 0= OFF 1 = 2 flashes per second 254 = 8 flashes per second 255 = solid ON As the DMX value is increased between 1 and 254, the number of flashes will increase linearly. Full control light fixture with Variable Intensity & Variable Rate: This mode will allow you to treat the same LED fixture as a strobe or as a lamp. 2 DMX channels are assigned to each of the 16 LEDs 2 2 per channel 3 1 per channel The first DMX channel sets the intensity: 0 = OFF 255 = Solid ON The intensity will increase linearly as the value changes from The second DMX channel sets the rate: 0 = OFF 255 = Solid ON The rate will increase linearly as the value changes from Lamp with Variable Intensity: This mode is used to treat the LEDs as luminaries with dimming. Uses the DMX value to set the intensity. 0 = OFF 255 = Solid ON The intensity will increase linearly as the value changes from

10 Standalone Operation When no DMX 512A signal is present, the LED BRIK Strobe System can be operated in standalone mode. In standalone mode the LED BRIK Strobe System will playback built in patterns. The built in patterns are as follows: PATTERN PATTERN DESCRIPTION 0 OFF: This pattern turns all channels off and keeps them off. 1 Random Blink: This pattern randomly blinks the 16 channels individually. All Blink: This pattern blinks all 16 channels simultaneously at a rate of about one 2 blink per second. Zipper Fast Blink: This pattern quickly strobe flashes each channel from channel 1 3 to channel 16. Zipper Slow Blink: This pattern blinks each channel for 0.5 seconds from channel 1 4 to channel 16. Zipper with Intensity Change: This pattern zippers through all the LEDs but ramps 5 the intensity of each channel from min to max as it cycles. Intensity Slide: This pattern increases the intensity of ALL the LEDs simultaneously 6 from min to max. Zipper with Intensity Change: This pattern zippers through all the LEDs while ramping the intensity for each cycle. 7 Cycles through the 16 channels at the minimum intensity Increases the intensity and cycles again Eventually it will reach maximum intensity.

11 LED Data for LEDs provided by Birket Specialty Lighting Color # Indicated on Watts Luminous Flux 1500 ma Dominant Wavelength 1000 ma Voltage [V f ma Voltage TYPICAL [V f ma Voltage TYPICAL [V f ma Current, Typical [I f ] ma Current, Peak [I f ] ma <10 10% Duty Junction Temp [T j ] o C heatsink Part Number Type 1 LZ4 00R115 RED LZ4 00G115 GREEN LZ4 00B215 BLUE LZ4 00A115 AMBER LZ4 00CW15 COOL WHITE LZ4 00WW15 WARM WHITE Viewing Angle [Degrees] K 6200 K (typical) K 3100 K (typical) Part Number Type Watts Luminous Flux 700 ma Dominant Wavelength 700 ma Voltage [V f ma Voltage TYPICAL [V f ma Voltage TYPICAL ma Current, Typical [I f ] ma Current, Peak [I f ] ma <10 10% Duty Junction Temp [T j ] o C 7 LZ4 00MC10 RGGB EMITTER RED GREEN GREEN BLUE Viewing Angle [Degrees] 7 LZ4 00MA10 RGBA EMITTER RED GREEN BLUE AMBER Part Number Type Watts Luminous Flux 700 ma Dominant Wavelength 350 ma Voltage [V f ma Voltage TYPICAL [V f ma Current, Typical [I f ] ma Current, Peak [I f ] ma <10 10% Duty Junction Temp [T j ] o C LXML PD RED LXML PM GREEN LXML PR ROYAL BLUE mw LXML PE CYAN LXML PH RED ORANGE LXML PL AMBER LXML PWC COOL WHITE K LXML PWN NEUTRAL WHITE K LXML PWW WARM WHITE K Viewing Angle [Degrees]

12

13

14

15

Compact, high-power, outdoor-rated, cable-free, battery-powered LED uplight with onboard wireless DMX, infrared remote, and manual control via OLED function menu + Six-unit road-worthy custom charging

More information

USER MANUAL Table of Contents

USER MANUAL Table of Contents USER MANUAL Table of Contents Safety Information. 3 Specifications.. 4 Main Power Connection..5 DMX-512 Connection...... 5 Main Control Menu... 6 DMX Profile... 8 Rigging the Fixture.9 Cleaning & Maintenance...9

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

INSTALLATION MANUAL. ION-CUBE Series. LED Wall Washer CLASS 2 E359853

INSTALLATION MANUAL. ION-CUBE Series. LED Wall Washer CLASS 2 E359853 INSTALLATION MANUAL IONCUBE Series LED Wall Washer CLASS 2 E359853 01/2018 INDEX Overview...1 Mounting...2 Wiring Stand Alone Single Color...3 Wiring Stand Alone RGB / RGBW...3 Wiring Stand Alone WW /

More information

USER MANUAL Table of Contents

USER MANUAL Table of Contents USER MANUA Table of Contents Safety Information.. 3 Specifications.. 4 Main Power Connection.. 5 DMX-512 Connection... 5 Main Control Menu... 6 DMX Profile... 9 Rigging the Fixture....10 Cleaning & Maintenance...10

More information

LED PROFILE SPOT - FULL COLOR

LED PROFILE SPOT - FULL COLOR LED PROFILE SPOT - FULL COLOR 2 15 WARNING! Before carrying out any operations with the unit, carefully read this instruction manual and keep it with cure for future reference. It contains important information

More information

SERIES. LINE OF LIGHT (No Pixelation) FLEXIBLE DIRECT VIEW LINE VOLTAGE 150 MAXIMUM RUN LOW VOLTAGE 32 MAXIMUM RUN OUTDOOR RATED

SERIES. LINE OF LIGHT (No Pixelation) FLEXIBLE DIRECT VIEW LINE VOLTAGE 150 MAXIMUM RUN LOW VOLTAGE 32 MAXIMUM RUN OUTDOOR RATED neonleds SERIES LINE OF LIGHT (No Pixelation) FLEXIBLE DIRECT VIEW highly flexible system LINE VOLTAGE 150 MAXIMUM RUN LOW VOLTAGE 32 MAXIMUM RUN OUTDOOR RATED Designed for indoor or outdoor use, the neonleds

More information

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08 GasScanner 4C Four Channel Monitor Operator s Manual MINT-0280-XX Rev. A 02/25/08 Product Warranty Matheson Tri-Gas., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,

More information

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder 1) Introduction The Appello tone and speech annunciation sounder has three different styles in AC and DC. A105NAPPX

More information

User Manual LIGHTMEN.COM. Apollo A75050

User Manual LIGHTMEN.COM. Apollo A75050 User Manual LIGHTMEN.COM Apollo A75050 TABLE OF CONTENTS 1 Introduction... 3 1. 1 Maintenance... 4 1.2 Operating elements and connections... 5 1.3 Menu button overview... 5 1.4 Operating elements and connections

More information

ElektraLite ElektraBar (6-in-1) Manual

ElektraLite ElektraBar (6-in-1) Manual ElektraLite ElektraBar (6-in-1) Manual ElektraLite (a division of Group One), 70, Sea Lane, Farmingdale, NY11735, U.S.A. T. +1 (631)-396-0184. F. +1 (631)-396-0190 WWW.MYELEKTRALITE.COM 1. Unpacking Thank

More information

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report LUXEON Rebel Photobiological Safety Report Application Brief AB60 LUXEON Rebel Photobiological Safety Report Introduction Light Emitting Diodes (LEDs) are incoherent, broad-band optical light sources that

More information

Installation Instructions

Installation Instructions Overview The SIMPLY5 Sensor Connector is used to provide an input for low voltage occupancy sensors and photocells. Use the S5SC with SIMPLY5-compatible lighting fixtures and control devices for fully

More information

DMX STROBE CANNON MODULE

DMX STROBE CANNON MODULE Home Page Back to Product Page DMX STROBE CANNON MODULE Installation and Operating Instructions DMX MODELS w/hyperflash 120V/ 240V 0477 / 0479 SCM-56Q-DMX (PAR 56 MODULE) 0476 / 0478 SCM-64Q-DMX (PAR 64

More information

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A GasScanner 1C Single Channel Monitor Operator s Manual MINT-0278-XX Rev A Product Warranty Matheson Tri-Gas, Inc., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,

More information

10yr O2NE & Safe-Ox. User Manual

10yr O2NE & Safe-Ox. User Manual Analox Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net This support line is closed on UK public

More information

dmx traits 02 3CH 04 4CH 05 5CH 03 4CH 10 10CH 09 9CH 13 36CH 14 38CH 12 36CH 15 43CH 16 45CH 17 48CH 18 49CH

dmx traits 02 3CH 04 4CH 05 5CH 03 4CH 10 10CH 09 9CH 13 36CH 14 38CH 12 36CH 15 43CH 16 45CH 17 48CH 18 49CH 3 3 8 3 3 3 3 3 DMX Channel Values / Functions Version (3 DMX Channels) 6 0 0CH 3 3 6 6 CH 3 3 8 0 3 3 3 3 6 6 3 8CH 8 6 6 LED GROUP -* 0- GROUP - GROUP 6- GROUP 3 8- GROUP 0- GROUP -3 GROUP 6 - GROUP

More information

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder 1) Introduction The Appello tone and speech annunciation sounder has three different styles in AC and DC. A105NAPPX

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

Altman Lighting Spectra Cyc UV 50 Specification

Altman Lighting Spectra Cyc UV 50 Specification 1.01 UV CYCLORAMA LIGHTING A. General 1. The fixture shall be a compact, lightweight color-mixing LED asymmetrical wash fixture with 8 or 16 bit DMX control of intensity and color. The fixture shall be

More information

Beacon 410A Gas Monitor Operator s Manual

Beacon 410A Gas Monitor Operator s Manual Beacon 410A Gas Monitor Operator s Manual Part Number: 71-0397 Revision: F Released: 12/5/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be

More information

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder AUTHORIZED DISTRIBUTOR ControlSystemsUSA.com Houston, Texas USA sales@controlsystemsusa.com 832-615-3588 INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

More information

OPERATION MANUAL FEATURES BEFORE USE JB SYSTEMS 1/14 ALIEN

OPERATION MANUAL FEATURES BEFORE USE JB SYSTEMS 1/14 ALIEN OPERATION MANUAL Thank you for buying this JB Systems product. To take full advantage of all possibilities and for your own safety, please read these operating instructions very carefully before you start

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

Combustible Gas and Hydrogen Sulfide Beacon 200 Rig Monitor Operator s Manual

Combustible Gas and Hydrogen Sulfide Beacon 200 Rig Monitor Operator s Manual Combustible Gas and Hydrogen Sulfide Beacon 200 Rig Monitor Operator s Manual Part Number: 71-0243RK Revision: E Released: 12/11/17 www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

User s guide. Multiple programming Electronic thermostat

User s guide. Multiple programming Electronic thermostat SYSTÈME QUALITÉ CERTIFIÉ - REGISTERED QUALITY SYSTEM User s guide STE402P+ Multiple programming Electronic thermostat Energy Verified For further information or to consult this guide online, please visit

More information

INTRODUCTION / TABLE OF CONTENTS

INTRODUCTION / TABLE OF CONTENTS 1 2 INTRODUCTION / TABLE OF CONTENTS Step One The LVCN 20 and LVCN 100 Series are general purpose level controllers offered in two configurations for pump and valve control. The LVCN 100 Series features

More information

Beacon 110 Gas Monitor Operator s Manual

Beacon 110 Gas Monitor Operator s Manual Beacon 110 Gas Monitor Operator s Manual Part Number: 71-0110RK Revision: H Released: 12/5/17 RKI Instruments, Inc. www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment

More information

Ethernet General Purpose

Ethernet General Purpose Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

Data Sheet Version 1.0

Data Sheet Version 1.0 LED Modules - Dim To Warm Round Power of Luminus in standard and custom LED modules Data Sheet Version 1.0 Lean & Fast. Made Smarter. Design Faster use standard modules to shorten development time Easy

More information

EW 40 Wireless Fan Control

EW 40 Wireless Fan Control Installation & Operating Manual EW 40 Wireless Fan Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4

More information

CONTROLS INSTRUCTIONS MANUAL ENGLISH

CONTROLS INSTRUCTIONS MANUAL ENGLISH CONTROLS INSTRUCTIONS MANUAL ENGLISH Table of Contents 1. Introduction of the Innova Controls 3 1.1 Precautions 3 2. Operating Instructions 2.1 Quick Start 4 2.2 Direction of Use 5 2.2.1 Heater on 5 2.2.2

More information

All pulses < 4Hz (>0.25sec) BLUE>400mW. As measured under IEC measurement conditions for classification.

All pulses < 4Hz (>0.25sec) BLUE>400mW. As measured under IEC measurement conditions for classification. THUNDERBOLTB NON-INTERLOCKED HOUSING WARNING This unit contains high power laser devices internally. Do not open the laser housing, due to potential exposure to unsafe levels of laser radiation. The laser

More information

M2 Rig Monitor Operator s Manual

M2 Rig Monitor Operator s Manual M2 Rig Monitor Operator s Manual Part Number: 71-0234RK Revision: D Released: 9/30/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before operating instrument.

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

Halo Programmable LED Aquarium Light. Quick Start Guide

Halo Programmable LED Aquarium Light.  Quick Start Guide Halo Programmable LED Aquarium Light www.tiaojiou.com Quick Start Guide 1. FEATURES - 25 LED array delivering rich color spectrum - Two groups (channels) of LEDs to optimize the light - Embedded Timers

More information

WM3000 WIRELESS MODULES

WM3000 WIRELESS MODULES WM3000 WIRELESS MODULES $$:05 $$:07 INSTALLATION INSTRUCTIONS Table of Contents Installation... 3 Mounting Instructions & Connections... 3 Setting the Dip Switches... 4 Setting the Recognition Time...

More information

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System Technical Bulletin AD-1272 Code No. LIT-12012477 Issued December 2017 Refer to the QuickLIT website for the most up-to-date version of

More information

LED Panels. We re excited to unveil our new LED Panels. These new LED panels are ideal for commercial use and fit into standard tile grid systems.

LED Panels. We re excited to unveil our new LED Panels. These new LED panels are ideal for commercial use and fit into standard tile grid systems. s s Energy savings up to 80% Zero maintenance Quick & easy installation Complies with Part L 2013 regulations Fully Dimmable IP54 protected against dust & moisture Superior light distribution s We re

More information

SAFETY INFORMATION AND WARNINGS

SAFETY INFORMATION AND WARNINGS This manual refers to the Model SST-3 control panel manufactured since October 31, 2013, which uses a universal (100 277 VAC; 50/60 Hz) power supply. Older units use a voltage-specific power supply and

More information

UL 153 portable electric luminaire Die-cast aluminum shell / tempered glass IP 65 Indoor/outdoor 150 rotary angle DMX-512 control.

UL 153 portable electric luminaire Die-cast aluminum shell / tempered glass IP 65 Indoor/outdoor 150 rotary angle DMX-512 control. SPHERE-STR LED WLL WSHER SPECIFICTION SHEET LISTED Features UL 153 portable electric luminaire Die-cast aluminum shell / tempered glass IP 65 Indoor/outdoor 150 rotary angle DMX-512 control pplications

More information

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08 GasScanner 8C Eight Channel Monitor Operator s Manual MINT-0281-XX Rev. A 01/29/08 Product Warranty Matheson Tri-Gas, Inc., warrants gas alarm equipment sold by us to be free from defects in materials,

More information

Stellar Panelboard Dimming Systems

Stellar Panelboard Dimming Systems create a new dimension in lighting control. While lighting systems consume energy, Stellar dimming panels conserve and redirect energy into the atmosphere of your facility. The panel s universal dimmers

More information

LightStation by SENNA

LightStation by SENNA LightStation by SENNA User Manual 1. Introduction LightStation is a system of LED panels and the wireless control plate which enables you to set and store different light presets and scenes which can be

More information

Skydance offers a complete AC Triac control system that contains Triac dimmer/ switch, Traic dimmable LED driver, and DMX512 Triac Converter.

Skydance offers a complete AC Triac control system that contains Triac dimmer/ switch, Traic dimmable LED driver, and DMX512 Triac Converter. 36 AC Triac Series Skydance offers a complete AC Triac control system that contains Triac dimmer/ switch, Traic dimmable LED driver, and DMX512 Triac Converter. The Triac dimmer with AC input and AC output

More information

INDICATOR LAMPS & LED REPLACEMENT LAMPS

INDICATOR LAMPS & LED REPLACEMENT LAMPS INDICATOR LAMPS & LED REPLACEMENT LAMPS M8 x 0.75 10.0 8.5 4.0 Chrome plated LED indicator 14.0 13.0 31.0 These indicators require a resistor to limit current. See note on page 53 for details. 55-432-0

More information

[Thermo Simple 2 (TS.2)] Thermo Simple 2 Manual. Refrigeration Innovation

[Thermo Simple 2 (TS.2)] Thermo Simple 2 Manual. Refrigeration Innovation Refrigeration Innovation Thermo Simple 2 Manual Refrigeration Innovation, LLC. 1250 Harter Avenue, Suite E Woodland, CA 95776 Ph: 530.666.3020 Fx: 530.666.3027 Refrigeration Innovation, LLC. 1250 Harter

More information

Exercise 1: IR Transmission and Reception

Exercise 1: IR Transmission and Reception Exercise 1: IR Transmission and Reception EXERCISE OBJECTIVE When you have completed this exercise, you will be able to explain how infrared light can be transmitted and received, describe typical infrared

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

FLAT STORM DMX CONTROL TABLE

FLAT STORM DMX CONTROL TABLE FLAT STORM DMX CONTROL TABLE 3 CH Mode 2 Auto Program 000-005 Blackout Auto Program 006-013 Auto Mix 1 014-021 Auto Mix 2 022-029 Auto Mix 3 030-037 Auto Mix 4 038-045 Auto Mix 5 046-053 Auto Mix 6 054-061

More information

Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group. Technical Product Information

Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group. Technical Product Information Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group Technical Product Information DCL with DEMANDflex DEMANDflex ballasts are high efficiency

More information

Instruction Manual Model Backup Switch, 1 for 8

Instruction Manual Model Backup Switch, 1 for 8 Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE

More information

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517) 3 4 Temperature Controller USER S MANUAL Aerotech, Inc. FORM: QM1386 4215 Legion Dr. Mason, MI 48854-1036 USA October 2010 Ph. (517) 676-7070 Fax (517) 676-7078 FOR CUSTOMER USE Enter the serial number

More information

FOS Strobe Light Bar 1

FOS Strobe Light Bar 1 FOS Strobe Light Bar 1 PRODUCT SPECIFICATIONS TECHNICAL SPECIFICATION Voltage: 110/240 Volt AC, 50/60 Hz. Power Consumption: 160 Watt. Light Source: 12 White strobe LEDs, 15 Watts each. Effects: Blinder

More information

QS941A Controller User Interface

QS941A Controller User Interface Product Manual Select Code 167-792-184 Comcode CC848816612 Issue 3 November 2009 Notice: The information, specifications, and procedures in this manual are subject to change without notice. Lineage Power

More information

USER MANUAL Table of Contents

USER MANUAL Table of Contents USER MANUAL Table of Contents Safety Information. 3 Specifications.. 4 Main Power Connection..5 DMX-512 Connection...... 5 Rigging the Fixture... 6 Installation...6 Main Control Menu... 8 DMX Profile 9

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE SM1206UV-405-IL Industry Standard 1206 Package RoHS Compliant UV Emitting LED Water Clear Lens Narrow Viewing Angle Ideal for Curing, Detection, and Medical

More information

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test SECTION 2 HGM300/RDM800 Mechanical Room layout SECTION 3 HGM300

More information

EFFICIENT LONG LIFE & ENERGY SERIES

EFFICIENT LONG LIFE & ENERGY SERIES treelite SERIES FIELD CUTTABLE LOW VOLTAGE GREEN OR CLEAR WIRE PARALLEL WIRING LONG LIFE & ENERGY EFFICIENT Designed for indoor or outdoor use, treelite series is ideal for many applications including

More information

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: These Time Delay Release Devices are U.L. Listed, Canadian Listed,

More information

PROJECT DATE FLANGE FINISH

PROJECT DATE FLANGE FINISH PROJECT INFORMATION PROJECT DATE TYPE 1" 2-1/2" BeveLED Recessed Downlight - Illuminate your space with any color available in the spectrum with BeveLED Infinite Color+. Tune the light from saturated blue,

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

Intensity Level. Intensity Control. Mounting Plate. Signal Type Switch Signal Ports USB DC Power Port

Intensity Level. Intensity Control. Mounting Plate. Signal Type Switch Signal Ports USB DC Power Port Dimmer User Manual OVERVIEW This product can dim up to 50 fixtures over 200 feet of signal wire via a 0-10V or PWM signal for uniform control of light intensity delivered to crops. Extending the signal

More information

Beacon 200 Gas Monitor Operator s Manual

Beacon 200 Gas Monitor Operator s Manual Beacon 200 Gas Monitor Operator s Manual Part Number: 71-0059RK Revision: J Released: 1/31/18 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

Z-350 Fazer Machine User Manual English

Z-350 Fazer Machine User Manual English Z-350 Fazer Machine User Manual English 2018 Antari Lighting and Effects Ltd. = User Manual Safety Information Please read the following safety information carefully before operating the machine. Information

More information

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

ACCESSORIES. Mounting LUMEN OUTPUT 2400K 1 PERFORMANCE. Lumen Maintenance. Warranty SERIES SHAPE COLOR VOLTAGE LENGTH CONFIGURATION

ACCESSORIES. Mounting LUMEN OUTPUT 2400K 1 PERFORMANCE. Lumen Maintenance. Warranty SERIES SHAPE COLOR VOLTAGE LENGTH CONFIGURATION FLEX DC NEON TOP is a high performance flexible LED fixture designed as a neon replacement but useful in a wide variety of applications where a smooth surface of light is desired. TOP bends towards and

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FOS BAR Pente 1 PRODUCT SPECIFICATIONS TECHNICAL SPECIFICATION Voltage: 110/240 Volt AC, 50/60 Hz Power Consumption: 180 Watt Light Source: 18x 12 Watt RGBW + Amber LEDs Effects: Red, Green, Blue, White

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

V-PIX Vision Bar LED Pixel Bar Light. User Manual KEEP THIS MANUAL FOR FURTURE NEEDS

V-PIX Vision Bar LED Pixel Bar Light. User Manual KEEP THIS MANUAL FOR FURTURE NEEDS V-PIX Vision Bar LED Pixel Bar Light User Manual KEEP THIS MANUAL FOR FURTURE NEEDS 1 Unpacking Thank you for choosing our Vision Bar For your own safety please read this manual before installing the device

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE Climate Cŏntrol Zoning System Installation Guide Uponor Climate Cŏntrol Zoning System Installation Guide Published by

More information

Water Source Heat Pump Module Technical Guide

Water Source Heat Pump Module Technical Guide Factory Packaged Controls Tulsa Water Source Heat Pump Module WSHP WSHP Protection Module Module Orion No.: OE334-23-WPM-A NON-DIGITAL COMPRESSORS #1 THRU #4 +5V SUCT. +5V SUCTION PR. SENSOR PRES PRES

More information

ELLA ID. High CRI, High lm/w OptoDrive LED-module

ELLA ID. High CRI, High lm/w OptoDrive LED-module ELLA ID ELLA ID High CRI, High lm/w OptoDrive LED-module Page 2 of 24 Pages for reference: Pages for reference:... 2 Introduction... 3 Short form Characteristics... 4 Wiring diagram:... 6 Accessories to

More information

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL INSTALLATION AND OPERATION GUIDE INTRODUCTION The NSI 804CP and 808CP represents a key part of a state of the art, total lighting control system. Combined with

More information

Product Manual SZ1009

Product Manual SZ1009 Product Manual SZ1009 Conventional Heating & Cooling Thermostats with Heat Pump Mode Communicating Thermostats Description The SZ1009 is a microprocessor-based mable thermostats designed for conventional

More information

Door Release Power Supply

Door Release Power Supply www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation

More information

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER PNEUMERCATOR Liquid Level Control Systems Electronic Systems Excluding LC2000 And TMS Series MAINTENANCE & TROUBLESHOOTING GUIDE 400 300 500 FUEL LEVEL LEAK MONITOR 1 200 600 OIL/GAS NORMAL WATER PNEUMERCATOR

More information

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000. INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA

More information

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg. WARD OXYGEN Installation, Operation, and Maintenance Instructions MEGA medical electronic gas alarm MEGA WARD MEGA medical electronic gas alarm WARD POWER SUPPLY Medical Electronic Gas Alarm OXYGEN SYSTEM

More information

CAUTION. Installation Manual

CAUTION. Installation Manual System Controller SC-301-6M CAUTION Installation Manual In order to use this product safely, read this installation manual carefully and follow the installation instructions. Potential dangers from accidents

More information

Order code: EQLA21 user manual

Order code: EQLA21 user manual TAURUS Order code: EQLA21 user manual Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain, moisture and

More information

MT-374B/364B Operation User s Guide. The Anti-Sweat Energy Saving Controller user s manual

MT-374B/364B Operation User s Guide. The Anti-Sweat Energy Saving Controller user s manual MT-374B/364B Operation User s Guide Parker Hannifin Canada Micro Thermo Technologies TM 12855 Brault Street Mirabel, QC J7J 0C4 Office phone 450-668-3033 Introduction The Anti-Sweat Energy Saving Controller

More information

RK-04 M2 Transmitter Operator s Manual

RK-04 M2 Transmitter Operator s Manual 65-2610RK-04 M2 Transmitter Operator s Manual Part Number: 71-0294RK Revision: 0 Released: 12/27/13 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before

More information

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially

More information

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation

More information

Kam StarWash Multicolour wash effects with green & red star cluster laser

Kam StarWash Multicolour wash effects with green & red star cluster laser Kam StarWash Multicolour wash effects with green & red star cluster laser M A N U A L V E R S I O N 2. 0 1 2-1 6 Due to continuous product development, please ensure that you have downloaded the latest

More information

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool Document Number 13I00-4 January, 1997 Copyright 1997 Home Automation,

More information

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications 56W Vapor Proof LED Fixture - 0-10V Dimmable - DALI Network - 7000 lms - IP67 - Outdoor Applications Part #: GVP-ADC-48-2L-LED-D-V2 Page: 1 The Larson Electronics GVP-ADC-48-2L-LED-D-V2 Dimmable LED Light

More information

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document Number 13I00-5 November, 1997 CONTENTS

More information

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1 Unit 7/8, Heathrow Causeway Estate, Ariel Way, Hounslow Middlesex, TW4 6JW +44 (0) 208 6302270 www.cpcuk.co.uk Universal Monitoring System Model IMEC8A User Manual Version 1.10 Software version 2.3.1-1

More information

Product Manual SZ1022/SZ1031/SZ1035/

Product Manual SZ1022/SZ1031/SZ1035/ Product Manual SZ1022/SZ1031/SZ1035/ Conventional Heating & Cooling Thermostats Communicating Thermostats Description The SZ1022, SZ1031, and SZ1035, are microprocessorbased mable thermostats designed

More information

Model: Available in : Sapphire Black and Glacier White. 1 Series

Model: Available in : Sapphire Black and Glacier White. 1 Series Model: Available in : Sapphire Black and Glacier White 1 Series Table of Contents Product Image 1 Frost Protection 20 Table of Contents 2 Power ON/OFF 21 What is a Programmable Room Thermostat? Installation

More information

General Purpose IO Technical Manual

General Purpose IO Technical Manual General Purpose IO Technical Manual Revision 1.06 8 November 2013 Pakton Technologies PAE222 GPIO Manual.docx Page 1 of 21 Revision 1.06 Last updated 8/11/2013 Table of Contents INTRODUCTION...3 Scope

More information

Analog Input Module IC670ALG630

Analog Input Module IC670ALG630 1 IC670ALG630 The Thermocouple (IC670ALG630) accepts 8 independent thermocouple or millivolt inputs. Module features include: Self calibration Two data acquisition rates based on 50 Hz and 60 Hz line frequencies

More information