The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

Size: px
Start display at page:

Download "The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report."

Transcription

1 Site Visit Report The site visit process is a sample on a particular day of an installation's compliance with some of its licence conditions. Where non-compliance against a particular condition has not been reported, this should not be construed to mean that there is full compliance with that condition of the licence. Instructions and actions arising from the visit shall be addressed, or where applicable noted, by the licensee in order to ensure compliance, to improve the environmental performance of the installation and to provide clarification on certain issues. The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report. Licensee Name of Installation Licensee Takeda Ireland Limited Takeda Ireland Limited Licence Register No. P CRO Site Address Site Visit Reference No. Grange Castle Business Park, Nangor Road, Dublin 22, Dublin SV12567 Report Detail Issue Date 10/10/2017 Prepared By Caroline Kelly Site Visit Detail Date Of Inspection 14/09/2017 Announced No Time In 10:00 Time Out 16:10 Agency Personnel On Site Licensee Personnel and Role Caroline Kelly Victor Olmos Donal Brady, Engineering Director Aileen Stack, Environmental Health and Safety Engineer Katherine Doyle, Environmental Health and Safety Engineer David McCarthy, Distribution Control System Automation Manager Colm Doyle, Maintenance Supervisor Photo Taken No Samples Taken No Video Taken No Odour Assessment No Site Visit Report - SV Takeda Ireland Limited Page 1 of 6

2 Scope This site visit was carried out to investigate the breaches of emission limit values (ELVs) at air emission point reference no. EP-P1-03 and to assess the performance and operation of the Volatile Organic Compound (VOC) scrubber at air emission point reference no. EP-P1-02. Media The following medium was inspected during the site visit: Air. Site Areas Inspected The following areas were inspected during the site visit: Hydrogenation scrubber unit in production building (PS1) Air emission point reference no. EP-P1-03 VOC recovery unit at air emission point reference no. EP-P1-02 Flame Ionisation detector (FID) unit at emission point reference no. EP-P1-02. Documents Inspected The following documents were inspected during the site visit: Air emission impact assessment submitted as part of licensee return reference no. LR regarding emission limit value (ELV) breach of TA Luft Class II on 18/03/2016 s 5.1 and Air monitoring report reference no. 8100/M73, Q Production schedule detailing proposed dates of product batches to be abated through VOC recovery unit to emission point reference no. EP-P1-02 or hydrogenation scrubber to emission point reference no. EP-P Schematic of hydrogenation scrubber (Drawing no. PJB0475) to emission point reference no. EP-P Schematic of VOC recovery unit 'VOC Recovery System Overview' from document reference SOP-ENG-UTIL-35. Site Visit Report - SV Takeda Ireland Limited Page 2 of 6

3 1. Site Specific Issues 1.1 Breaches of ELVs at EP-P1-03 Checked 5.1 Yes The Agency and the licensee discussed breaches of ELVs as at emission point reference no. EP-P1-03, in particular: TA Luft Class II on 11/05/2017 of > & <312.09mg/m3 versus an ELV of 100mg/m3 (see incident reference no. INCI012001) TA Luft Class III on 16/08/2017 of 228mg/m3 versus an ELV of 150mg/m3 (see incident reference no. INCI012840) The licensee stated that it was investigating the breaches. The TA Luft Class II breach of 11/05/2017 occurred during a step 4 hydrogenation phase of a product called 'PSPA'. The TA Luft class III breach of 16/08/2017 occurred during the production of a product called 'TAK-438'. The licensee stated that this was the last batch of 'TAK-438' planned and that it was unlikely that it would be produced again. Further production of 'PSPA' has been scheduled for April The licensee stated it was currently investigating the cause of the TA Luft Class II breach during the PSPA process and establishing proposed corrective actions. These have yet to be finalised. The Agency requested an update on the progress of an impact assessment into the TA Luft Class II breach on 11/05/2017, which was required to be submitted by 14/08/2017 in accordance with the Agency's instruction issued under incident reference no. INCI The licensee stated that its consultants were in the process of finalising the assessment report and it would be submitted to the Agency. The Agency opened a compliance investigation (CI) reference no. CI related to breaches of ELVs at EP-P1-03. Corrective actions required: The licensee shall: Submit an impact assessment in relation to the TA Luft Class III ELV breach of 16/08/2017 as required under CI Action and Instruction reference no.'s A and A This assessment report was subsequently submitted to the Agency on 02/10/2017 and is currently being assessed by the Agency. Submit an impact assessment report as required under INCI in relation to the TA Luft Class II ELV breach of 11/05/2017. This assessment report was subsequently submitted to the Agency on 29/09/2017 and is currently being assessed by the Agency. Submit a final investigation report into the TA Luft Class II ELV breach on 11/05/2017 as required under CI Action reference no. A by 27/10/ VOC recovery unit bypasses at EP-P1-02 Checked 5.1 Site Visit Report - SV Takeda Ireland Limited Page 3 of 6

4 The Agency reviewed six bypass events at the VOC recovery unit at emission point reference no. EP-P1-03, which occurred during the period 30/01/2015 and 11/03/2016. The Agency requested an update on the progress of corrective actions required under Section 7.2 of site visit reference no. SV08358 which required the licensee to address bypasses of the VOC Recovery unit. There have been no recorded bypasses since 11/03/2016, as recorded under incident reference no. INCI The license stated that the carbon bed was taken apart and underwent a full inspection and maintenance during the last plant shutdown in July The activated carbon absorption media has been replaced. The licensee has established a preventative maintenance programme in order to eliminate bypass events. This involves a trend analysis of measured TOC levels with action limits to ensure preventative maintenance is carried out before a bypass occurs. Daily checks on the VOC unit are also carried out. There is an interlock in place whereby production shutdown occurs where a reading of 50ppm or higher TOC is recorded. 1.3 Flame Ionisation Detector (FID) at EP-P1-02 Checked 5.4, 11.5, 11.7 Yes The FID hut was visited during the site visit. The licensee explained the arrangements of the two FIDs on site. Only one unit is operative and carries out measurements at a time, the second unit is kept warm to make it operative when needed. The following issues were observed on site: 1. The sample gas was not presented at 180 CDeg to the analyser. The current heated line is only installed up to the CEMS hut, once there flexible unheated tubing is used to bring the sample gas to the analysers. This is not in compiance with section 5.1 of EN 12619:2013 Stationary source emissions Determination of the mass concentration of total gaseous organic carbon Continuous flame ionisation detector method Standard. 2. It was confirmed on site that methane was used as the span gas for the calibration of the FIDs. This was not in compliance with section 4.1 and of EN 12619:2013 standard. 3. When commisioning the standby FID unit, a single span check using methane is carried out. No checks at zero are performed. Section of EN Standard requires the use of a zero gas with a TVOC concentration lower than 0.2 mg/m3 of carbon or purity %. 4. The measurement ranges of the FIDs are limited to 100ppm. Any reading above this limit is recorded as 100ppm. This would not allow the correct assessment of the potential impact of emissions during bypass events if elevated concentrations of solvents are released. Corrective actions required: The licensee shall: Comply with the requirements of EN standard. Special attention shall be taken on the mandatory sampling train requirements and calibration procedure. Ensure that the FID measurement range is adjusted at all times according to the concentration of emissions being released at any given time. 1.4 Impact assessment report re: INCI Checked 4.2 No Yes Site Visit Report - SV Takeda Ireland Limited Page 4 of 6

5 The impact assessment report submitted under licensee return reference no. LR as a response to the incident INCI was discussed. This report included an air dispersion model. The stack exit velocity parameter used in the air dispersion model was 14,260.3 m/s. The Agency queried this velocity parameter. Corrective action required: The licensee shall review and confirm the accuracy of the data used for the air dispersion model and where the data is incorrect, the licensee shall resubmit an amended assessment report. Site Visit Report - SV Takeda Ireland Limited Page 5 of 6

6 Summary The licensee breached ELVs for TA Luft Class II and TA Luft Class III organics at emission point reference no. EP-P1-03 on 11/05/2017 and 16/08/2017 respectively. The Agency opened a compliance investigation reference no. CI in relation to the breaches and instructed the licensee to submit an impact assessment and investigation report. Previous incident reports concerning bypass events at the VOC recovery unit at emission point reference no. EP-P1-02 were evaluated and the licensee has implemented appropriate corrective actions. There hare been no bypass events at EP-P1-02 since 11/03/2016. s were made in relation to air emissions, abatement, monitoring and impact assessment, which will require corrective action by the licensee. FOLLOW-UP ACTIONS You are required to complete the instructions and actions, as outlined in this report, within the specified timeframe. Where required, you shall respond to actions specified in Investigations within the required timeframe.the licensee shall maintain documentary evidence, for review by the EPA, that the prescribed corrective actions were completed within the required timeframe. (i) Investigations You are not required to respond directly to items contained in this EPA site visit report; where an issue requires a direct response, the EPA will generate a Investigation through the EDEN system. You will receive notification when a Investigation instruction or action is generated. (ii) Publication of reports and licensee response. Please note that this Site Visit Report will be made available for public viewing via the EPA s Licence Enforcement Access Portal within one day of the issue date and will be published on the Licence Details Page of the EPA s website, that relates to your licence 60 calendar days after the issue date. You may if you choose submit, within 45 calendar days of the issue date of this Site Visit Report, a Licensee Public Response that will be published alongside the Site Visit Report. This Response, should you wish to avail of it, provides you with an opportunity to inform the public about how you are implementing the actions set out in the report, activities underway, timescales and target completion dates. Please be aware that the content of your Licensee Public Response must be factual and should not breach the EPAs stated online publication standards. If you wish to submit a Licensee Public Response to an EPA Site Visit Report, you should do this by clicking on the Make a Response link on the Site Visits page in EDEN. A.pdf document containing your response can be attached and submitted from here. (iii) Response to Site visit report Where you do wish to respond directly to a site visit report, you should do this by generating a Licensee Return of the type Site Updates/Notifications and the sub-type Response to EPA Report in EDEN. Please note that you are required to comply with the conditions of your licence at all times, and where noncompliance occurs you must restore compliance within the shortest possible time. These actions will be verified during subsequent EPA visits. Please quote the above Inspection Reference in any future correspondence in relation to this Report. Site Visit Report - SV Takeda Ireland Limited Page 6 of 6

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection Procedure No: SOP-020 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, and to

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVF}heinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000059868 AMs designation: Manufacturer: Test Laboratory: FIDAMAT 6 MEASURING SYSTEM fortoc SIEMENS AG Östliche

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the 3000HM Flame Ionisation Detector 3010 & 3030 Portable Flame Ionisation Detector manufactured by: Signal Group Ltd 12 Doman Road Camberley Surrey,

More information

Complete Gas Analysis

Complete Gas Analysis Complete Gas Analysis A complete range of gas analysers, systems and accessories for emissions, air quality, research and process monitoring. The Signal Group, incorporating the gas analysis business of

More information

Series 9000 Total Hydrocarbon Analyzer

Series 9000 Total Hydrocarbon Analyzer Series 9000 Total Hydrocarbon Analyzer Analyzer The Baseline Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides

More information

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex Part 2 Direct Reading Instrumentation Direct Reading Instruments Many different instruments Many different operating principles including: Electrochemical Photoionisation Flame ionisation Chemiluminescence

More information

Irish Water. Technical Standards REMOTE ASSET MANAGEMENT (RAM) POLICY. Water Treatment Fluoridation. Document Number: IW-RAM-SPEC

Irish Water. Technical Standards REMOTE ASSET MANAGEMENT (RAM) POLICY. Water Treatment Fluoridation. Document Number: IW-RAM-SPEC Irish Water Technical Standards REMOTE ASSET MANAGEMENT (RAM) POLICY Water Treatment Fluoridation Document Number: IW-RAM-SPEC-5020-009 Document Revision: 1.0 Page 1 of 14 CONTENTS Contents 2 1.0 Introduction

More information

Leak Detection and Repair METHOD 21 AND OPTICAL GAS IMAGING

Leak Detection and Repair METHOD 21 AND OPTICAL GAS IMAGING Leak Detection and Repair METHOD 21 AND OPTICAL GAS IMAGING LT Environmental, Inc. www.ltenv.com Today we will discuss: Method 21 Devices Combining Optical Gas Imaging (OGI) with Method 21 Federal Programs:

More information

Management Practices: Fire Protection Impairments November 2015

Management Practices: Fire Protection Impairments November 2015 RiskTopics Management Practices: Fire Protection Impairments November 2015 When business capital is invested in fire protection, it is difficult to explain any fire protection outage that allows a fire

More information

DIRECTIVE NO: D-B

DIRECTIVE NO: D-B DIRECTIVE NO: D-B6 100604 1 LOW PRESSURE THERMAL FLUID PLANT AUTOMATED CONTROL SYSTEMS Date of Issue: June 4, 2010 General Details This directive is being issued to owners, licensed contractors, consulting

More information

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca. Monitoring Parameter: Methane and Non-Methane Hydrocarbons Revision No: Draft Revision Date: 09 April, 2018 Title: Standard Operating Procedure for the Non-Continuous Measurement of Ambient Methane and

More information

For inspection purposes only.

For inspection purposes only. Attachment F.1 Neutralisation System Process Description The CPG process generates both acid and caustic waste water from the acid/base leaching processes. This waste water will be collected in dedicated

More information

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples Process and Air Monitoring Online GC systems for continuous monitoring of organic compounds in air and gaseous samples For 35 years AMA Instruments has developed and manufactured analytical devices and

More information

HFID Heated Total Hydrocarbon Analyzer Module

HFID Heated Total Hydrocarbon Analyzer Module Product Data Sheet PDS 103-685.A01 October, 2003 NGA 2000 HFID Heated Total Hydrocarbon Analyzer Module Heated analyzer designed to operate from 200 F to 400 F Eliminates loss of hydrocarbons due to condensation

More information

Glenside Environmental Services Ltd

Glenside Environmental Services Ltd Unit 18 Great Island Industrial Park, Ballincollig, Co. Cork. Testing Laboratory Registration number: 322T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 16429 March 2013 ICS 13.040.40 English Version Stationary source emissions - Sampling and determination of hydrogen chloride

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland`jR' Procis ly Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000053816 AMs designation: Manufacturer: Test Laboratory: U3600-QALl for dust Auburn systems LLC S Electronics

More information

DSO Compliance Report 2009

DSO Compliance Report 2009 DSO Compliance Report 2009 ESB Networks Ltd 31 st March 2010 Introduction ESB Networks Ltd was vested as Distribution System Operator (DSO) on 1 st January 2009 in accordance with the European Communities

More information

STANDARD OPERATING PROCEDURE FOR EMERGENCY FIRE

STANDARD OPERATING PROCEDURE FOR EMERGENCY FIRE STANDARD OPERATING PROCEDURE FOR EMERGENCY FIRE SOP Number: 3T MRI 210.03 Version Number & Date: 3rd version; 01 Feb 2009 Effective Date: 01 Feb 2009 Superseded Version Number & Date (if applicable): 210.02

More information

International comparison of validation methods for dust concentration measurement

International comparison of validation methods for dust concentration measurement International comparison of validation methods for dust concentration measurement Validation of dust monitors can be divided into 2 steps: 1. Validation of a generic dust monitor as an instrument (Type

More information

Signing Up... 1 Logging in for the First Time... 2 The Search Panel... 3

Signing Up... 1 Logging in for the First Time... 2 The Search Panel... 3 A Guide to Using TABLE OF CONTENTS Signing Up... 1 Logging in for the First Time... 2 The Search Panel... 3 Keywords... 3 Type... 3 Location... 3 Current Status... 3 On Site... 3 Commencement Received...

More information

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide

More information

PROPOSED October 15, 2013

PROPOSED October 15, 2013 RULE 4308 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS 0.075 MMBtu/hr to less than 2.0 MMBtu/hr (Adopted October 20, 2005, Amended December 17, 2009, Amended [rule adoption date]) 1.0 Purpose The purpose

More information

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME Aspetti gestionali e verifiche periodiche (norma UNI EN 14181:2015) Walter Battaglia - Alessandro Migatta - Sandro

More information

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection. PRODUCT GUIDE Unrivalled Gas Detection. ABOUT ION SCIENCE UNRIVALLED GAS DETECTION What we do Ion Science is a leading UK manufacturer of technologically advanced gas detection insruments and sensors,

More information

Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by

Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by 2 Sponsored by: Boiler MACT Deadline Is Here, Are You In Compliance? Webinar Presentation January 21, 2016 PH Haroz President Conversion

More information

POLICY. Carbon Monoxide (CO) is an odorless, colorless gas that can cause sudden illness and death. 1

POLICY. Carbon Monoxide (CO) is an odorless, colorless gas that can cause sudden illness and death. 1 POLICY Number: 7311-20-020 Title: Carbon Monoxide Monitoring and Reporting Overnight Stay Facilities Authorization [ ] President and CEO [X] Vice President, Finance and Corporate Services Source: Director,

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland'ä` Procis Iy Ftight. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000032301_01 AMs designation: fornox, S02, CO, C02and 02 Manufacturer: Test Laboratory: HORIBA Europe GmbH

More information

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd Selecting the right generator for your GC system By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd Selecting the right generator for your GC system Gas generators offer a guaranteed

More information

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY Revision No.: 11 Page 1 of 12 I. PURPOSE This procedure establishes a tool to help maintain a safe environment for all patients, visitors and staff by evaluating the loss of a life safety feature during

More information

Operate the Mutli-Gas Monitor PID

Operate the Mutli-Gas Monitor PID TASK: Operate the Multi-Gas Monitor Learning Objective CONDITION: In a classroom environment, given a fully charged Multi-gas Monitor with the manufacturer operator s manual, all monitor components/accessories,

More information

Aromatics and Oxygenates in Gasoline June2018

Aromatics and Oxygenates in Gasoline June2018 SRI has configured in a single GC two common tests performed on gasoline. The first test is a a simplified version of ASTM 4815, oxygenates in gasoline. The second test is a simplified version of ASTM

More information

Recent Improvements in Process GC Instrumentation

Recent Improvements in Process GC Instrumentation ISA Houston, TX Oct., 15 2003 Recent Improvements in Process GC Instrumentation Dr. Jack Driscoll PID Analyzers, LLC copyright 2000-2006 PID Presentation Objectives A new Process GC has been developed

More information

Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air.

Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air. Cover Sheet Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air. PURPOSE: Some earlier generation air purifiers, have been shown to release ozone or secondary

More information

AS/NZS :2008

AS/NZS :2008 AS/NZS 60079.29.2:2008 Australian/New Zealand Standard Explosive atmospheres Part 29.2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen AS/NZS 60079.29.2:2008

More information

TICKET INFORMATION UTILIZATION BYLAW

TICKET INFORMATION UTILIZATION BYLAW TICKET INFORMATION UTILIZATION BYLAW CONSOLIDATED THIS IS A CONSOLIDATION, FOR REFERENCE PURPOSES, OF: Greater Vancouver Regional District Ticket Information Utilization Bylaw No. 1050, 2006 (Adopted July

More information

EuroFID Gas Analyzers for Measurement of the Total Hydrocarbon Content

EuroFID Gas Analyzers for Measurement of the Total Hydrocarbon Content Front page OPERATING INSTRUCTIONS EuroFID Gas Analyzers for Measurement of the Total Hydrocarbon Content Installation Operation Maintenance Document Information Described Product Product name: EuroFID

More information

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels. Gas Chromatograph Continuous Analysis of Ultra High Purity Argon to ppb levels Features Following on from the success of the AGC Series 100 Argon GC, AGC Instruments introduces the new NovaCHROM 2000 GC.

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60079-29-2 Edition 2.0 2015-03 Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen INTERNATIONAL

More information

C-NRPP Quality Assurance Guidance for Radon Test Devices

C-NRPP Quality Assurance Guidance for Radon Test Devices C-NRPP Quality Assurance Guidance for Radon Test Devices Table of Contents: 1. Purpose 2. Definitions 3. Quality Assurance Plan 4. Calibration 5. Spikes/Performance Tests 6. Duplicates 7. Blanks 8. Cross-Checks

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 12039 First edition 2001-06-15 Stationary source emissions Determination of carbon monoxide, carbon dioxide and oxygen Performance characteristics and calibration of automated

More information

Safety Systems Review Retail Guidance and specification Version

Safety Systems Review Retail Guidance and specification Version Systems Review Retail Guidance and specification Version 1 2014 Membership Training Qualifications Audit and Consultancy Policy and Opinion Awards Contents Page Systems Review 1 1 Specification for Systems

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000050625 Certified AMS: Manufacturer: Test lnstitute: A02000-Fidas24 for TOC ABB Automation GmbH Stierstädter

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 25140 First edition 2010-08-01 Stationary source emissions Automatic method for the determination of the methane concentration using flame ionisation detection (FID) Émissions

More information

+91-8048413395 Applied Techno Systems http://www.appliedtechnosystem.com/ We are industry leading Manufacturer and Supplier firm delivering state of art Gas Monitoring and Analyzing System. We aim to satisfy

More information

FACILITY PROFILE ARBEC FOREST PRODUCTS INC. PRODUITS FORESTIERS ARBEC INC. Oriented Strand Board Mill Miramichi, N.B. Prepared by:

FACILITY PROFILE ARBEC FOREST PRODUCTS INC. PRODUITS FORESTIERS ARBEC INC. Oriented Strand Board Mill Miramichi, N.B. Prepared by: FACILITY PROFILE ARBEC FOREST PRODUCTS INC. PRODUITS FORESTIERS ARBEC INC. Oriented Strand Board Mill Miramichi, N.B. Prepared by: Impact Management Branch Department of Environment and Local Government

More information

Patriot Systems Limited

Patriot Systems Limited COPYRIGHT 1997 - The Patriot Systems Ltd. Patriot Alarm Monitoring Automation Package is licensed for use on one computer, by the original person, or company, or organisation whose name is registered with

More information

Boiler MACT Webinar Q/A

Boiler MACT Webinar Q/A Boiler MACT Webinar Q/A Q: How much modification can be done to a boiler or process heater before it is considered to be New? A: An existing boiler can be considered to be a New boiler if modifications

More information

Standard Development Timeline

Standard Development Timeline Standard Development Timeline The drafting team maintained this section while developing the standard. It will be removed when the standard becomes effective. Description of Current Draft This draft is

More information

IRO Reliability Coordinator Real-time Reliability Monitoring and Analysis Capabilities

IRO Reliability Coordinator Real-time Reliability Monitoring and Analysis Capabilities A. Introduction 1. Title: Reliability Coordinator Real-time Reliability Monitoring and Analysis Capabilities 2. Number: IRO-018-1 3. Purpose: Establish requirements for Real-time monitoring and analysis

More information

Information Guide Maintenance and Refrigerant Regulations. Issue 35

Information Guide Maintenance and Refrigerant Regulations. Issue 35 Information Guide Maintenance and Refrigerant Regulations Issue 35 Guide to Maintenance and Refrigerant regulations This is an independent guide produced by Mitsubishi Electric to enhance the knowledge

More information

Ministry Ministère Order Issued Pursuant to s.35(14) of of the de O. Reg. 419/05 Environment l Environnement. Benzene and Climate et de l Action en

Ministry Ministère Order Issued Pursuant to s.35(14) of of the de O. Reg. 419/05 Environment l Environnement. Benzene and Climate et de l Action en Ministry Ministère Order Issued Pursuant to s.35(14) of of the de O. Reg. 419/05 Environment l Environnement Benzene and Climate et de l Action en Change matière de changement climatique Expiry Date: November

More information

Subpart M National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities

Subpart M National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities Subpart M National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities The Environmental Protection Agency promulgated in the July 27, 2006 Federal Register National Perchloroethylene

More information

PASCOE S PTY LTD EMERGENCY RESPONSE MANUAL. (Public Version) SOP 531. July 2015

PASCOE S PTY LTD EMERGENCY RESPONSE MANUAL. (Public Version) SOP 531. July 2015 PASCOE S PTY LTD EMERGENCY RESPONSE MANUAL (Incorporating) Pollution Incident Response Management Plan (Public Version) SOP 531 July 2015 Unit 2 #97 LISBON STREET FAIRFIELD EAST, NSW 2165 TELEPHONE: 02

More information

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions Important: Keep these User Instructions for reference 2 TABLE OF CONTENTS GENERAL SAFETY

More information

USING A REAL TIME SIMULATOR IN A LARGE AND COMPLEX ROAD TUNNEL FOR TIME AND COST SAVINGS

USING A REAL TIME SIMULATOR IN A LARGE AND COMPLEX ROAD TUNNEL FOR TIME AND COST SAVINGS USING A REAL TIME SIMULATOR IN A LARGE AND COMPLEX ROAD TUNNEL FOR TIME AND COST SAVINGS Lars Elertson, Swedish Transport Administration Abstract 56 km of tunnel tubes compose the road tunnel E4 Stockholm

More information

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN )

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN ) Page 1 of 7 All tests and sampling performed by the laboratory meet the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009. The Laboratory is qualified to update standards

More information

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features. Features To measure and take control of indoor air quality Three noses in same unit Air Quality (VOC), Humidity (rh) and Temperature (T) Selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc via jumpers on pcb

More information

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning This initiative was developed by: Content and guidance kindly provided by the following organisations: Cool Drive CPS Asia Pacific

More information

VOCs in soil remediation

VOCs in soil remediation A buyer s guide to measuring VOCs in soil remediation Typical photoionisation detectors measure volatile organic compounds and other gases in concentrations from sub parts per billion to 10 000 parts per

More information

IRceL CH4 Methane (CH 4

IRceL CH4 Methane (CH 4 Product Datasheet IRceL CH4 Methane Sensor Document Purpose The purpose of this document is to present the performance specification of the IRceL CH4 Methane gas sensor. This document should be used in

More information

AIR POLLUTION CONTROL REGULATION NO. 23 CONTROL OF PERCHLOROETHYLENE EMISSIONS FROM DRY CLEANING OPERATIONS. Promulgated December 2, 2003

AIR POLLUTION CONTROL REGULATION NO. 23 CONTROL OF PERCHLOROETHYLENE EMISSIONS FROM DRY CLEANING OPERATIONS. Promulgated December 2, 2003 AIR POLLUTION CONTROL REGULATION NO. 23 CONTROL OF PERCHLOROETHYLENE EMISSIONS FROM DRY CLEANING OPERATIONS Promulgated December 2, 2003 RHODE ISLAND DEPARTMENT OF ENVIRONMENTAL MANAGEMENT OFFICE OF AIR

More information

Patriot Systems Limited

Patriot Systems Limited COPYRIGHT 1997 - The Patriot Systems Ltd. Patriot Alarm Monitoring Automation Package is licensed for use on one computer, by the original person, or company, or organization whose name is registered with

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the FIDAMAT 6 FID Analyser manufactured by: Siemens Production Automisation S.A.S. 1 Chemin de la Sandlach B.P. 189 F-67506 Haguenau Cedex France

More information

Refrigerant Management Requirements Update

Refrigerant Management Requirements Update Refrigerant Management Requirements Update Georgia A&WMA Regulatory Update Conference May 11, 2017 Katie Brubaker Agenda Regulatory background pursuant to changes to rule Extension of refrigerant rules

More information

Archived Content. This content was archived on August 24, 2016.

Archived Content. This content was archived on August 24, 2016. This content was archived on August 24, 2016. Archived Content The Marihuana for Medical Purposes Regulations (MMPR) are no longer in effect and have been archived. They were replaced by the new Access

More information

Category V. NOTE: Fire Investigations are covered in Criterion 5D.

Category V. NOTE: Fire Investigations are covered in Criterion 5D. Category V Criterion 5B: Fire Prevention/Life Safety Program The agency operates an adequate, effective, and efficient program directed toward fire prevention, life safety, hazard risk reduction, the detection,

More information

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

The Louis Berger Group, Inc. 15 January 2016

The Louis Berger Group, Inc. 15 January 2016 15 January 2016 THE Louis Berger Group, INC. 350 Eagleview Boulevard, Suite 250, Exton, Pennsylvania 19341-1178 Tel 610 280-4000 Fax 610 363-5390 www.louisberger.com Ms. Anne J. Wolf Facilities R&A Team

More information

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Operation and Maintenance Manual GDS-48 Remote Bridge Sensor for Combustible Gases AUTHORIZED DISTRIBUTOR: GasDetectorsUSA.com - Houston, Texas USA sales@gasdetectorsusa.com - 832-615-3588 CAUTION: FOR

More information

ENVIRONMENTAL STANDARD OPERATING PROCEDURE 7 DEGREASING SOLVENT

ENVIRONMENTAL STANDARD OPERATING PROCEDURE 7 DEGREASING SOLVENT ENVIRONMENTAL STANDARD OPERATING PROCEDURE 7 DEGREASING SOLVENT 1. Version, Date. 3, 07 Sep 2014 (EMS) 2. Purpose. This Environmental Standard Operating Procedure (ESOP) establishes general use procedures

More information

Thermo Scientific TVA2020 Introduction

Thermo Scientific TVA2020 Introduction Thermo Scientific TVA2020 Introduction The Thermo ScientificT TVA2020 Toxic Vapor Analyzer, is an advanced design, portable, organic/inorganic vapor monitor for the gas survey industry. The analyzer uses

More information

Fire System Impairment Policy

Fire System Impairment Policy Fire System Impairment Policy Purpose: To establish procedures to be followed, when a fire protection or suppression system is taken out of service, due to construction, alteration, power outage, repair,

More information

Daikin VRV Sizing & Simulation Plug-in User Guide

Daikin VRV Sizing & Simulation Plug-in User Guide Daikin VRV Sizing & Simulation Plug-in User Guide IES Virtual Environment Copyright 2015 Integrated Environmental Solutions Limited. All rights reserved. No part of the manual is to be copied or reproduced

More information

Inspection Detail. General Questions for Laser Labs

Inspection Detail. General Questions for Laser Labs Laser Lab Inspection Checklist Building/Room: Authorized User: Inspection #: Inspection Detail 1 This inspection is General Questions for Laser Labs 2 Laser Users List Verified by Laser Supervisor? 3 Laser

More information

(h) Pesticide Application.

(h) Pesticide Application. Fire Code Cannabis Amendment Section 13.20.066 is added to the Marysville Municipal Code to read in its entirety as follows: 13.20.066 Cannabis Growing, Processing, or Extraction Facilities (a) Application.

More information

Air-Quality Detection Module. User s Manual

Air-Quality Detection Module. User s Manual Air-Quality Detection Module (Model:ZP07-MP901) User s Manual Version: 1.1 Valid from 2014-11-10 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual s copyright belongs to Zhengzhou

More information

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

A Notification under Article 12 of Regulation (EU) No 1025/2012 1 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Sustainable Growth and EU 2020 Standards for Boosting Competitiveness Brussels, 02/07/2014 A Notification under Article 12 of Regulation

More information

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951) Riverside County Fire Department Office of the Fire Marshal 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4777 Fax (951) 955-4886 Technical Policy Title: Plant Processing and Extraction

More information

Requirements for ships carrying hydrogen and compressed natural gas vehicles

Requirements for ships carrying hydrogen and compressed natural gas vehicles Lloyd's Register briefing IMO FP 55 Summary report for clients Overview The 55 th session of the IMO Fire Protection Sub Committee (FP) was held from 25 th to 29 th July 2011, at the IMO headquarters in

More information

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3. Rev. 1 03/05/2015 ANNEX A to the Yokogawa Corporation of America Quality Assurance Manual For Additional Requirements selectively applied to ATEX and IECEx certified products CONTENTS 1. Scope 2. Purpose

More information

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1)

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1) ST-IAM Sensor Transmitter Integrated Area Monitor Check / Calibration Procedure* Content Page 1-Introduction 2 2-Bump Test 2 3-Calibration 3 a. Exchanging sensor board 3 b. Gas Calibration 3 4-Additional

More information

Content Copy Of Original

Content Copy Of Original Content Copy Of Original General Mills Canada Corporation 111 Pillsbury Dr Midland, Ontario L4R 4L4 Site Location: 111 Pillsbury Drive Midland Town, County of Simcoe Ministry of the Environment Ministère

More information

EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM

EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM Page: 1 of 12 EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM TABLE OF CONTENTS 1. PURPOSE... 2 2. SCOPE... 2 3. REFERENCES... 2 4. DEFINITIONS... 3 5. RESPONSIBILITIES... 4 NOTE: LICENCE

More information

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security E²M Enhanced Environmental Mass Spectrometer Innovation with Integrity Safety & Security Enhanced GC/MS System The E 2 M is the successor to the highly successful and proven GC/MS system EM 640. It represents

More information

RK-05 Carbon Monoxide Detector Operator s Manual

RK-05 Carbon Monoxide Detector Operator s Manual 65-2433RK-05 Carbon Monoxide Detector Operator s Manual Part Number: 71-0189RK Revision: 0 Released: 5/17/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

HYDROCARBONENGINEERING June June 2015

HYDROCARBONENGINEERING June June 2015 www.hydrocarbonengineering.com Controlled Combustion Arthur Groenbos, Yokogawa Europe, discusses tunable diode laser gas analysis for combustion management in fired heaters. While fired heaters are used

More information

Certificate: _01 / 2 February 2015

Certificate: _01 / 2 February 2015 Test report: 936/21210059/A of 21 October 2009 Initial certification: 12 February 2010 Certificate: renewal (previous certificate 0000025931 of 10 March 2010 valid until 11 February 2015) Expiry date:

More information

Date Issued: December 14, 2017 Revision: 2.1

Date Issued: December 14, 2017 Revision: 2.1 2.1 1. Introduction A is implemented to ensure the fire safety of building occupants or a building area when the Fire Alarm System or a Fire Protection System has been temporarily disabled due to malfunction,

More information

Fall 2018 ECE608 Computational Models and Methods

Fall 2018 ECE608 Computational Models and Methods Fall 2018 ECE608 Computational Models and Methods Prerequisite: Graduate Standing Time and Place: TTh 12:00-1:15pm SC239 Instructor: Professor Irith Pomeranz MSEE234, 494-3357, pomeranz@ecn.purdue.edu

More information

RK-02 Multi Point Detector Operator s Manual

RK-02 Multi Point Detector Operator s Manual 65-2485RK-02 Multi Point Detector Operator s Manual Part Number: 71-0237RK Revision: A Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles 1, 2, 3, 4, and 5 Gas Detectors Quick Reference Guide Limited Warranty & Limitation of Liability BW Technologies Ltd.

More information

Datalogging as standard

Datalogging as standard Datalogging as standard for expanded performance Autofim II and Autofim II GC have a sophisticated datalogging system, as standard, which enables you to keep a permanent data record. The memory is capable

More information

GEORGIAN COLLEGE OPERATING PROCEDURES & PRACTICES. Revised Responsible Procedure Date: Department: Administration Number: LOCKDOWN

GEORGIAN COLLEGE OPERATING PROCEDURES & PRACTICES. Revised Responsible Procedure Date: Department: Administration Number: LOCKDOWN GEORGIAN COLLEGE OPERATING PROCEDURES & PRACTICES Revised Responsible Procedure Date: 01.31.12 Department: Administration Number: 2-121 LOCKDOWN PURPOSE: SCOPE: To provide general direction to the College

More information

GUARDED STATUS INFORMATION and REQUIREMENTS For OWNERS AND OPERATORS Of REFRIGERATION PLANTS

GUARDED STATUS INFORMATION and REQUIREMENTS For OWNERS AND OPERATORS Of REFRIGERATION PLANTS GUARDED STATUS INFORMATION and REQUIREMENTS For OWNERS AND OPERATORS Of REFRIGERATION PLANTS [Second Revised Edition] April, 2003 Issued by: Mechanical and Engineering Branch Room 500, Norquay Building

More information

Canadian Fire Alarm Association. Fire Alarm System Activation. Fire Alarm with malfunction history

Canadian Fire Alarm Association. Fire Alarm System Activation. Fire Alarm with malfunction history Canadian Fire Alarm Association Discussion topics False alarms Shut off notices Owner s responsibilities Documents required by AHJ Fire Alarm System Activation Fire detection (early warning at insipient

More information

EMERGENCY OPERATIONS PLAN Revision 4.0

EMERGENCY OPERATIONS PLAN Revision 4.0 Annex A- Purpose To provide an overview of the responsibilities and the procedures whereby the notification of key University officials and the warning of the general public, Students and employees are

More information

portable gas analyser

portable gas analyser www..com portable gas analyser Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy. The device is contained in a compact soft casing. Analyser

More information

X0.01 Emergency Management. Approved: September 27, 2002 Revised: July 15, Next Scheduled Review: July 15, 2014 PROCEDURE STATEMENT

X0.01 Emergency Management. Approved: September 27, 2002 Revised: July 15, Next Scheduled Review: July 15, 2014 PROCEDURE STATEMENT Texas A&M AgriLife Extension Service Procedures 34.07.99.X0.01 Emergency Management Approved: September 27, 2002 Revised: July 15, 2012 Next Scheduled Review: July 15, 2014 PROCEDURE STATEMENT Texas A&M

More information