1 Systèmes de blocage I m p a n t i d i b l o c c o Feststellanlagen Arrester systems Sistemas de bloqueo ARRESTER SYSTEMS
2 2 Breaking new grounds, making use of new technologies, developing new ideas. Founded in 1936, the company effeff from Albstadt became the market leader in the field of door control systems by following a consistent strategy. After starting the electric strike production in 1947, a comprehensive product range has been gradually developed, which enables effeff to offer suitable solutions for every door. February 1st, 2000, effeff joined the ASSA ALBOY Group based in Stockholm, Sweden. ASSA ABLOY is the leading manufacturer and supplier of mechanical and electromechanical locks and related products worldwide. The Ritz-Carlton,Wolfsburg Airport Hamburg
3 3 effeff s customers now profit from the group s wide know-how, offering everything for total security and comfort throughout the world. With worldwide sales activities in more than 75 countries and with highly experience make effeff the expert for electromechanical security a reliable and competent partner in all areas.the company attaches great importance to customer orientation and service. Whatever you want to safeguard, protect, preserve effeff offers the right solution! Airport Munich Trade Fair, Leipzig
4 4
5 CONTENTS ABOUT US CONTENTS ARRESTER SYSTEMS THE PRINCIPLE Components SMOKE PROTECTION SWITCHES Unit Versions FIRE ALARMS Technical Data Mounting and Installation ARRESTER DEVICES Overview of Electromagnets Electromagnets Spacers Counter Holding Plates Switching Elements REGULATIONS AND GUIDELINES Acceptance of the Arrester System and tests PRODUCT OVERVIEW FAX ORDER FORM
6 6
7 ARRESTER SYSTEMS Safety First Reliable Protection It is a legal requirement that fire doors be kept closed at all times. This is important because fire doors are an effective way of preventing the spread of dangerous smoke and fumes from a fire. On the other hand, you need barrier-free passageways for unhindered movement of persons and efficient work processes, for example in hotels, kindergartens, hospitals and business premises. Two Requirements, One Solution How can these two conflicting requirements be met? With arrester systems from effeff. The principle is simple but extremely effective. Each fire door is fitted with a door closer and a arrester device. Normally, the arrester device, an electromagnet, holds the door open. Visitors can pass unhindered, and business operations are not hampered by the continual opening and closing of the doors. Smoke detectors monitor the critical zones. When danger threatens, the smoke detectors fully automatically detect even the slightest concentrations of smoke or fumes day or night, even at weekends and outside working hours. They immediately send a message to the smoke protection switch. This interrupts the current supply to the electromagnet, and the door closer closes the door automatically, without outside intervention. This effectively prevents the spreading of the highly toxic smoke and fumes. If there are still people in the area of the fire, they can escape by the doors, the door closer reliably ensuring that the doors are again closed tightly against the smoke after each person has passed. The Complete System effeff offers all the components needed for a functioning system: smoke detectors, smoke protection switches, magnets and counter holding plates, and interruptor pushbutton. All the elements in this system are harmonised with each other and carefully tested. This guarantees reliable functioning and a long, uncomplicated lifetime. For reliable protection of persons and property. 7
8 Rauchmelder Rückstellung Tür freigeben Betrieb Auslösung Rauchmelder Rückstellung Tür freigeben Betrieb Auslösung Rauchmelder Rückstellung Tür freigeben Betrieb Auslösung Rauchmelder Rückstellung Tür freigeben Betrieb Auslösung THE PRINCIPLE Why Fire Barriers? Mains connection 230 V Fire and smoke doors, smoke flaps and similar installations are legally required fire barriers. In case of a fire, they prevent toxic fumes, smoke and flames from spreading through openings in walls and ceilings. This protects people and preserves the value of property. Fire barriers must be kept closed at all times. Output for external signals The disadvantage: Closed doors hamper the movement of persons and goods. The danger: The fire barriers are kept open by wedges or something of the sort. In case of fire, the barriers can no longer serve their purpose, and lives are endangered. Magnet cable, 2-core Input smoke detectors, 2-core 8 The solution: effeff arrester systems hold fire barriers open. Persons and goods can pass freely. When danger threatens, that is, when a fire is only just starting, the fire barriers are closed reliably. Their protective function takes over reliably. Output smoke detectors, 2-core The Functional Principle Fire barriers must be self-closing. However, to allow persons and goods to pass unhindered, the barriers are normally kept open by arrester systems. Should a fire start, the smoke detectors detect the increased concentration of smoke and fumes. The doors are released, and close automatically. Terminator resistance 2.4 kω The fire barriers are normally held open by magnets. Persons and goods can move unhindered. Should a fire start, the magnets are switched off and the fire barriers close. Persons who are in the room can flee safely. The fire sections are closed off. The escape routes remain free of smoke.
9 Rauchmelder Rückstellung Tür freigeben Betrieb Auslösung COMPONENTS The Components Arrester systems for fire barriers always consist of several components: The arrester devices (magnets), which normally hold the doors open. In the case of an alarm, or when triggered manually, they release the doors. Planning and Installation of Arrester Systems Arrester systems for fire doors must have a general certificate from the inspector of works. Effeff arrester systems are licensed by the Deutsche Institut für Bautechnik (DIBt, German Institute for building technology). They hold the system licence Z The smoke detectors, which are mainly installed in the form of optical smoke detectors. They monitor the concentration of smoke and fumes in the room. If this concentration increases, they put the fire alarm box in alarm mode. Another method is to monitor the room temperature. Heat sensors are used for this purpose. If the room temperature rises quickly, or exceeds 58 C, the alarm boxes go into alarm mode. The smoke protection switch, the central power supply and distribution unit in the system. The signals from the smoke detectors arrive here and are evaluated. In case of an alarm, or if the integrated trigger switch is actuated, the smoke protection switch switches the magnets off. The doors can now close securely, thus shutting off the rest of the building. The manual triggering buttons, mounted immediately next to the doors to allow them to be closed manually. When this button is pressed, the electrical circuit to the magnets is interrupted, and the door is closed V AC 3 2 Smoke Rauchschutzschalter protection switch Manual triggering Hand- Auslösetaster button Smoke Brandmelder detector Feststelleinrichtung Arrester device (z.b. (e.g. Haftmagnet) 2 The following units are licensed for use in the system. You may operate these units only together and as part of a arrester system for fire barriers: Smoke protection switch: Model Model Smoke Detector: Optical smoke detector Model Thermo-differential detector Model Locking equipment: 1. Magnets 1.1 effeff 837 (force of adhesion 300 N) 1.2 effeff 838 (force of adhesion 800 N) 1.3 effeff 858 (force of adhesion N) 2. Door closer with electrical-mechanical locking 2.1 Dorma door closer TS 73 EMF, EMF/S 2.2 Dorma door locking device TS EMF 2.3 Dorma TS 93 GSR / EMF Dorma TS 93 GSR / EMF Dorma BTS 80 EMB, EMB/S 2.6 Dorma BTS 80 FLB 2.7 Geze TS 540 E 2.8 Geze TS 550 E, E-IS 2.9 Geze TS 4000 E, E-IS, EFS 2.10 Geze TS 5000 E, E-IS 3. Sliding gate drives 3.1 Dorma radial coupling EMS 3.2 Dorma radial coupling EMS Dorma face coupling EMS-3 Manual triggering button: Model 1316 Model
10 SMOKE PROTECTION SWITCH 10 Central Power Supply and Processing Unit The smoke protection switch accommodates the mains adapter for the power supply of the entire arrester system and the evaluation electronics. At the core of the system, the smoke protection switch evaluates the incoming signals from the smoke detectors. If the signals indicate too high a concentration of smoke and fumes, or too high a temperature, the smoke protection switch interrupts the supply of electric current to the magnets. The fire doors close, preventing the further spread of smoke and fire to the next section of the building. Technical data Model Model Nominal voltage connection 230 V, 50 Hz Nominal operating voltage 24 V DC from internal mains adapter Nominal current consumption approx. 35 ma approx. 115 ma (typically) (typically) Outputs 24 V, 250 ma 24 V, 800 ma The overall current consumption of all external users (magnets and external signal transmitters) must not be exceeded. Relay outputs 1 x potential-free 24 V, 30 W 1 x potential-free 230 V, 5 A Max number of smoke detectors attachable Operating temperature range 0 C bis +40 C Storage temperature range -20 C bis +60 C Degree of protection IP 30 (acc. to DIN EN , ) Protection class I (acc. to VDE 0106 T 1) DIBT licence Z Housing Plastic Colour light grey (RAL 7035) Weight approx. 630 g approx g Dimensions W 166 mm 213 mm H 160 mm 184 mm D 81 mm 93 mm Several arrester systems can be connected to one common smoke protection switch. Max. Number of magnets attachable Model Model Model 837 up to 3 up to 10 Model 838 up to 2 up to 8 Model 858 up to 1 up to 3
11 UNIT VERSIONS Unit Versions Two versions are licensed as smoke protection switches: 81 mm 93 mm 160 mm 184 mm 166 mm 213 mm Smoke protection switch Continuous current consumption for external users: up to 250 ma Smoke protection switch Continuous current consumption for external users: up to 800 ma
12 SMOKE DETECTORS Which smoke detector for which room? The system licence permits the use of two types of smoke detectors in effeff arrester systems: Optical smoke detector Model Heat sensitive, thermo-differential detector Model Which type of detector you should use depends on the probable source and development of a fire. Almost all fires start with a smouldering phase. Long before a blaze starts, the fire is detectable by the presence of smoke and fumes. In locking systems for fire barriers, optical smoke detectors are used almost exclusively, because they can detect smoke and fume particles in the air reliably. 12 Use heat sensors only in exceptional cases in: Rooms in which dust, smoke, steam or aerosols occur, because here the smoke detectors could trigger even under normal operating conditions. Examples: woodworking, kitchens, etc. Rooms in which a fire could start without a smouldering phase, or with only a short one. Examples: ignition of solvent fumes, fluids, etc. Tip: Smoke detector rather than heat sensor Give the use of smoke detectors the priority. In the case of arrester systems for barriers in escape routes and for smoke doors, smoke detectors are compulsory.
13 TECHNICAL DATA Optical Smoke Detector Heat Sensitive, Thermo-differential Detector With pedestal and LED display for individual identification. For connection to smoke protection switches Model : Optical smoke detectors work on the principle of diffused light With pedestal and LED display for individual identification. For connection to smoke protection switch. The thermo-differential detector serves to detect fires that cause a rapid rise in temperature. It works on the principle of rise in temperature within specific unit of time and the threshold temperature value. According to EN 54, Part 5, Class 1 with a threshold temperature of 58 C. Temperature rise per minute = 4 C Model Bracket Complete with pedestal fixing screws Technical data Optical smoke detector Temp. diff. detector Model Model Nominal operating voltage 12 V DC Nominal current consumption approx. 60 µa approx. 75 µa (deadweight) (deadweight) approx. 15 ma (alarm) approx. 15 ma (alarm) Operating -5 C bis +60 C -5 C bis +70 C temperature range Storage -25 C bis +70 C -25 C bis +70 C temperature range Degree of protection IP 42 (acc. to DIN EN , ) Threshold values 58 C, 4 C per min. Housing Plastic Colour white (RAL 9010) Dimensions ø 101,5 mm, H 80 mm
14 SMOKE DETECTORS Function Optical smoke detectors work on the principle of diffused light. The interior of the smoke detector forms a labyrinth, so that no external light can penetrate it. The pulsed measuring light beam is reflected by any smoke that has entered, and falls on the light-sensitive element. Here, the incidence of light causes the current to increase. When the threshold value is exceeded, smoke is recognised and the alarm signal is triggered. Photo transmitter LED Smoke in the measuring chamber Optical smoke detectors react very promptly, especially in the case of smouldering fires with large, light-coloured smoke particles. Their advantage lies in the prompt reaction to smouldering plastics, blazing plastics and smoking, burning fluids. Labyrinth Photo receiver Reflection Alarm signal Installation with Wall Openings 14 Monitoring Range of smoke detectors Usually, several smoke detectors are needed to provide optimum monitoring. Smoke detectors have a limited monitoring range of up to 4 metres in diameter. When reading the following explanations, bear in mind that the entire width of the opening must always be monitored. In the case of openings wider than 4 metres, or by very high ceilings, you must install correspondingly more boxes. Is the door a rotating door? What is the distance between the top of the doorway and the ceiling on one or both sides? Up to 1m Yes No Greater than 1m Number of smoke detectors The required number of smoke detectors and their correct mounting depend on structural criteria of the building. The following diagram shows a simple way to determine the minimum required number: How wide is the doorway? Up to 3m Greater than 3m 1 Lintel box Min. 2 boxes (one ceiling box each side) Min. 3 boxes (one ceiling box each side and one lintel box on one side)
15 MOUNTING AND INSTALLATION Mounting Dimensions and Prescribed Distances 1 2 The distance between the top of the doorway and the ceiling is up to 1 metre, and the door had turning leaves with an opening of up to 3 metres. max. 3 m max. 1 m max. 0,1 m You need at least one lintel detector on one side or the other. Always mount the lintel detector in a vertical position. If necessary, use the mounting bracket, It is best to mount the lintel box in the centre, directly above the opening and a maximum of 0.1 meters from the top of the doorway. The distance between the top of the doorway and the ceiling is up to one metre, the door is a sliding or roller gate, or a turning door with an opening more than 3 metres wide. 1 2 max. 1 m min. 0,5 m 15 You need at least 2 detectors, i.e. one ceiling detector each side. Always mount the ceiling detectors on the ceiling that is fire-protection classified, i.e. on the first seamless, smoke-proof ceiling. At any rate, however, install it where the highest concentration of smoke and fumes is to be expected first. Always mount the box vertically above the opening in the wall. The distance between the opening and the wall must be at least 0.5 metres and must not exceed 2.5 metres. more than 3 m min. 0,5 m max. 2,5 m max. 2,5 m Note! In the case of openings wider than 4 metres, you must install correspondingly more smoke detectors. Note! Non-licensed detectors and detectors that are mounted differently or in different areas from those described above, can be attached, but do not count as effective smoke detectors as defined in the DIBt memos.
16 SMOKE DETECTORS The distance between the top of the doorway and the ceiling is greater than 1 metre. The type of door does not matter. 1 2 You need at least 3 detectors, i.e. one ceiling detector on each side and one lintel detector on one side. Always mount the lintel detector upright. If necessary, use the mounting bracket, It is best to mount the lintel detector in the centre, directly above the opening and not more than 0.1 metres away from the top of the doorway. Always mount the ceiling detectors on the ceiling that is fire-protection classified, i.e. on the first seamless, smoke-proof ceiling. At any rate, however, install it where the highest concentration of smoke and fumes is to be expected first. Always mount the detector vertically above the opening in the wall. The distance between the opening and the wall must be at least 0.5 metres and must not exceed 2.5 metres. greater than 1 m max. 0,1 m min. 0,5 m max. 2,5 m 16 The distance between the top of the doorway and the ceiling is greater than 5 metres. 1 2 You need at least 3 detectors, i.e. one ceiling detector on each side and one lintel detector on one side. The ceiling detectors may be mounted on brackets 0.5 metres long. You must affix these brackets at least 3.5 metres above the top of the doorway. The regulations for the lintel detectors still apply. Always mount the lintel detector upright. If necessary, use the mounting bracket, It is best to mount the lintel detector in the centre, directly above the opening and not more than 0.1 metres away from the top of the doorway. greater than 5 m max. 0,1 m 0,5 m 0,5 m min. 3,5 m Note! In the case of openings wider than 4 metres, you must install correspondingly more smoke detectors. Note! Non-licensed detector and detector that are mounted differently or in different areas from those described above, can be attached, but do not count as effective alarm boxes as defined in the DIBt memos.
17 MOUNTING AND INSTALLATION Installation With Openings in Ceilings 3 There are special regulations concerning openings in ceilings: Mount at least one smoke detector on the ceiling of each storey. The boxes must not be more than 0.5 metres from the edge of the opening in the ceiling. Assume a maximum monitoring radius of 2 metres for the smoke detectors. In the case of larger openings, install several detectors in such a way that the entire cross-section of the opening is monitored. At the upper end of the ceiling opening you must mount a detector over the centre of the opening. 2 1 max. 0,5 m Monitoring radius max. 2,5 m max. 0,5 m max. 0,5 m Installation in through-going shafts (e.g. lift shafts) 17 In through-going shafts, the same regulations as for wall openings apply, with the following additions: 2 Install an additional ceiling detector in the centre of the ceiling of the shaft. When an smoke detector is triggered, at least the barriers on the same floor and on the floors above must close. max. 0,1 m 1 min. 0,5 m max. 2,5 m When the upper ceiling detector is triggered, all the barriers associated with the shaft must close.
18 ARRESTER DEVICES Holding Magnets The comprehensive range of effeff magnets covers all types of application. Whether for mounting on the wall or the floor with appropriate spacers effeff is your competent partner, world wide. Use of door closers with integrated arrester devices instead of magnets is permissible only when they have system approval. Magnets with Diodes Magnets for integration in fire alarm systems and other electrical systems can be supplied with a built-in recovery and polarity reversal protection diode. Order supplement... with diode 18 Magnets and Counter Holding Plates Are made of special magnetic soft iron. This ensures optimum adhesion with low power consumption and slight residual adhesion. Magnets and counter holding plates must therefore always be ordered together. The surfaces of the magnets and counter holding plates are nickel plated. The magnets may be combined with mounting housings and spacers. Ease of Mounting The counter holding plates are always larger in diameter than the corresponding magnets. This makes it easier to adjust to the magnet when mounting the counter holding plate, because the excess size of the plate takes the mounting tolerances into account.
19 OVERVIEW ELECTROMAGNETS Example of wall mounting Example of floor mounting Model Model Model 838 A with mounting plate and covered connecting terminal 19 Model Model 838/839 BW 1 Spacer Model /839 BW 2U Heavy Duty Version Model Model 838 igw in cast aluminium housing Model Model 838 igb in cast aluminium housing
20 ARRESTER EQUIPMENT Magnets Version A With mounting plate and concealed connection terminal. Series 837 Holding force 300 N Model 837 A Model 837 BC Version BC Cable connection changeable to side or back. Back connection with 2 M5 screws for spacer or building-side holder. 837A F90 837BC F90 Series 838 Holding force 800 N Model 838 A Model 838 BC A F90 838BC F90 Technical data Model Model Model Operating voltage 24 V DC Nominal current approx. 0,075 A approx. 0,09 A approx. 0,25 A consumption (typically) (typically) (typically) Nominal power approx. 1,8 W approx. 2,1 W approx. 6 W consumption (typically) (typically) (typically) Switch-on time 100 % ED Operating temperature range 0 C to +50 C Operating temapprox. 45 C perature at 20 C approx. 45 C approx. 45 C Degree of protection IP 40 (acc. to DIN EN , ) Nominal holding force up to 300 N up to 800 N up to 1800 N DIBt approval Z Dimensions Vary with version Series 858 Holding force 1800 N Model 858 A 858A F90 Model 858 BC 858BC F90
21 ELECTROMAGNETS Magnets Version is Wall-mounting version in plastic housing Version igw In aluminium housing for wall mounting Model 838 is without cut out switch 838iS F90 Model 838 is/u with cut out switch 838iS/U-----F90 Holding force 800 N Version igb In aluminium housing for floor mounting Version.../U With cut out switch Model 838 igw without cut out switch 838iGW------F90 Model 838 igw/u with cut out switch 838iGW/U----F90 Holding force 800 N Model 838 igb without cut out switch 838iGB------F90 Model 838 igb/u with cut out switch 838iGB/U----F90 Holding force 800 N 21 Always mount the arrester devices at the point at which the force of the door closer is applied. This prevents warping of the door leaf. The door closer takes effect at the top, so mount the arrester unit at the top. The door closer takes effect at the bottom, so mount the arrester unit at the bottom.
22 ARRESTER EQUIPMENT Magnets Spacers for Floor and Wall Mounting of Magnets Spacer 839 Convertible for floor or wall mounting. Always order the desired model of magnet and spacer together. Model 837/839 without cut out switch 837/ F90 Model 837/839 U with cut out switch Model 838/839 without cut out switch 838/ F90 Model 838/839 U with cut out switch 837/839U----F90 Dimensions Distance from wall Distance from floor Holding force 95 mm 60 mm 300 N 838/839U----F90 Dimensions Distance from wall Distance from floor Holding force 98 mm 60 mm 800 N 838/ Spacer 839 BW... The 839 BW... spacers can be modified for floor or wall mounting. Spacer tube for mounting the magnet is available in 4 standard lengths. Always order the desired model of magnet and spacer 839 BW... together. Version.../U with cut out switch Model 838/839 BW 1 without cut out switch 838/839BW1--F90 Model 838/839 BW 1 U with cut out switch 838/839BW1U-F90 Dimensions Distance from wall Distance from floor Holding force 115 mm 70 mm 800 N Model 858/839 BW 1 without cut out switch 858/839BW1--F90 Model 858/839 BW 1 U with cut out switch 858/839BW1U-F90 Dimensions Distance from wall Distance from floor Holding force 127 mm 70 mm 1800 N 838/839 BW 1 U Version BW Convertible for floor or wall mounting Convertible for floor or wall mounting Model 838/839 BW1U-F90 BW2U-F90 BW3U-F90 BW4U-F90
23 SPACERS ELECTROMAGNETS Model 838/839 BW 2 without cut out switch 838/839BW2--F90 Model 838/839 BW 2 U with cut out switch 838/839BW2U-F90 Dimensions Distance from wall Distance from floor Holding force 155 mm 110 mm 800 N Model 858/839 BW 2 without cut out switch 858/839BW2--F90 Model 858/839 BW 2 U with cut out switch 858/839BW2U-F90 Dimensions Distance from wall Distance from floor Holding force 167 mm 110 mm 1800 N 838/839 BW 2 U Model 838/839 BW 3 without cut out switch 838/839BW3--F90 Model 838/839 BW 3 U with cut out switch 838/839BW3U-F90 Model 858/839 BW 3 without cut out switch 858/839BW3--F90 Model 858/839 BW 3 U with cut out switch 858/839BW3U-F90 23 Dimensions Distance from wall Distance from floor Holding force 265 mm 220 mm 800 N Dimensions Distance from wall Distance from floor Holding force 277 mm 220 mm 1800 N 838/839 BW 3 U Model 838/839 BW 4 without cut out switch 838/839BW4--F90 Model 838/839 BW 4 U with cut out switch 838/839BW4U-F90 Model 858/839 BW 4 without cut out switch 858/839BW4--F90 Model 858/839 BW 4 U with cut out switch 858/839BW4U-F90 Dimensions Distance from wall Distance from floor Holding force 395 mm 350 mm 800 N Dimensions Distance from wall 407 mm Distance from floor 350 mm Holding force 1800 N 838/839 BW 4 U
24 ARRESTER EQUIPMENT Magnet Mating Plates Mounting plate with articulated magnet counter holding plate Model Model Model Counter holding plate on mounting fixture with cushioning spring, softening the impact of heavy doors Model 837-2P Model 838-2P Model 858-2P 837-2P P P P 838-2P 858-2P
25 MAGNET MATING PLATES ELECTROMAGNETS Magnet mating plates on mounting plate, adjustable for extreme angles between door and magnet Model Model Model Note! Fire barriers must be able to withstand fires. You must not drill holes in them, and you must use only attachment material with a melting point of above 1000 C. Attach the magnet counter holding plates on steel doors only with steel M5 riveted nuts and steel screws. With wooden doors, use steel woodscrews. The screws must not penetrate the wood any farther than 3 / 4 of the thickness of the door leaf. Mount the magnet counter holding plates on the door leaf so that the attachment screws are not more than 150 mm from the upper or lower edge and from the vertical edge on the side on which the lock is (see illustration on the right). max. 150mm max. 150mm Max. distances for mounting the magnet mating plate
26 ARRESTER EQUIPMENT SWITCHING ELEMENTS Contact-breaker Button For manual release of the arrester system Surface-mounted interrupter pushbutton with red actuating surface and lettering Tür schließen Dimensions: W 61 x H 61 x D 22 mm Flush-mounted interrupter pushbutton with red actuating surface and lettering Tür schließen Dimensions: W 81 x H 81 x Ø 55 mm Marking the Door Areas Acceptance of the Arrester System and Inspections 26 The areas of the fire barriers must be made recognisable. You can do this by applying coloured markings to the floor and ceiling, or, if this is not practicable, by signs on the fire barriers themselves. There is no prescribed form for these signs. However, to make them conspicuous, we recommend signs roughly 300 mm x 150 mm at least with a red border. Inspection interval Arrester systems for fire barriers must be inspected regularly: After installation in the form of an acceptance test by authorised specialists, Once a month by the operator, and Once a year by authorised specialists. The inspections must be initiated by the operator. Each inspection must be logged. Draw the operator s attention to these inspections. The Acceptance Inspection When a arrester system has been installed ready for operation in the position where it is to be used an acceptance test must be carried out to ensure that it is working properly and has been installed correctly. The manufacturer of the release and locking equipment must point out the need for this inspection. The operator must initiate it. According to DIBt, effeff locking equipment may be acceptance-tested only by: effeff specialists, or Specialists from a recognised test centre, or Specialists who have been authorised by effeff.
27 REGULATIONS AND GUIDELINES The acceptance inspection must include the following points: 1. The units built into the arrester system must be identical with the units specified in the approval certificate. 2. The identification of the installed units must be identical with the identification specified in the approval certificate. 3. The interplay of all the devices must be inspected on the basis of the approval certificate, and must be triggered both by simulating the category of fire for which the smoke detector is designed, and by hand. When the acceptance inspection is complete, the operator must affix the acceptance plate to the wall close to the barrier. Successful acceptance is documented in the acceptance log Routine Monitoring The operator must keep the arrester system ready for operation at all times, and check it for proper functioning at least once a month. 4. The inspection must show whether the barrier is released for automatic closing when the locking system becomes functional (e.g. by removing a smoke detector or by cutting off the power). In addition, the operator is duty bound to have an inspection of the proper, fault-free interplay of all units carried out and maintenance done at least once a year, unless a shorter interval is specified in the approval certificate. Note! Fire barriers are for saving lives! The following points are therefore most important: 1. The fire barriers must be functional. They must move easily and automatically and be able to close without hindrance. They must not be blocked by objects, nor must they scrape on floor, wall or ceiling. 2. The areas around the fire barriers must always be kept clear. Nothing must be set down in them. Objects must not hang into the area of the door. Take care the objects cannot fall into the areas of the barriers. These inspections and maintenance must be carried out only by a specialist or by a person specially trained for the task. Scope, results and date of the regular inspection must be logged. The log entries must be stored by the operator
28 effeff products PRODUCTS ELECTRIC STRIKES By activating an electric strike, you unlock your door at the push of a button without having to go to the door. effeff electric strikes offer total security and comfort. Our wide product range meets every requirement and offers the suitable strike for any application. This can be guaranteed world-wide as effeff takes national and international regulations completely into account. HIGH SECURITY STRIKES Even the most peculiar requirements are not a problem to us: within the wide range of special and fire door electric strikes, effeff offers completely solutions. Our comprehensive product range for particular high security requests needs every legal regulation and offers high level solutions for fire doors and escape doors to our own high quality standards. Besides, effeff provides the right product even for special applications such as interlock control, clean room doors and outer applications. 28 DOOR AND MOTORIZED BOLTS effeff door bolts and motorized power bolts are a reliable complement to locks and strikes. They are suitable for applications on special doors (e.g. swing and sliding doors) where they are often installed as additional locking. In case of door bolts with integrated monitoring contact, the locking status can be monitored so that a system can start only when the relevant door is safely locked. The applications vary from simple drawers to elevator doors and highsecurity areas. ESCAPE DOOR SYSTEMS Thanks to the comprehensive escape door systems range, effeff meets every demand for people s security and secure the enviroment. You can trust effeff s know-how and reliability even in case of danger. Our escape door systems always guarantee the correct functioning of the escape doors: this concerns the authorized unlocking of the door as well as its locking. In case of danger, absolutely safe use of the escape door is totally granted. effeff escape door systems guarantee protection and security in department stores, schools, nursery schools, premises, airports and fair pavilions as well. Besides, we offer solutions even for special applications such as protected areas of clinics.
29 effeff products PRODUCT PRODUCTS SECURITY LOCKS Just rely on security: thanks to the panic function and the automatic locking, effeff electric security locks guarantee the highest mechanical security as well as the most convenient service for the customers. effeff s lock range is suitable for application in fire doors as well as for use on escape doors. MAGNETS One of the important elements of the effeff locking devices range is the wide variety of magnets in different shape. Thanks to a low noise mechanism and the comfort of a simple mounting, the magnets are extremely suitable for additional door locking. Moreover, effeff offers high-quality surface magnets. Their modern design fits to harmoniously to the environment. 29 ACCESS CONTROL SYSTEMS Easy solutions for more security! effeff access control systems are designed to protect and control buildings, rooms or high-security areas. Different technologies, devices and systems are available and fitting every specific requirement. effeff access control systems made to our customer s requests and can be used in private, official and industrial areas. ARRESTER SYSTEMS effeff arrester systems secure fire doors that have to be left open during normal use. As soon as smoke is detected, the arrester system mechanism releases the door. The fire doors then close avoiding smoke and fumes spreading to rooms and buildings nearby and restricting the spreading fire as well.
30 NOTES 30
31 It is our intention to continue to keep abreast of calls for further technical developments and innovations. For this reason, we reserve the right to make design changes. Despite meticulous care taken in publication, printing or other errors cannot be excluded. effeff is unable to accept any liability and enters into no obligation whatsoever.
32 Systèmes de blocage I m p a n t i d i b l o c c o Feststellanlagen Arrester systems Sistemas de bloqueo effeff Fritz Fuss GmbH & Co. Kommanditgesellschaft auf Aktien Bildstockstraße Albstadt GERMANY Tel Fax info@effeff.com G000 An ASSA ABLOY Group company
Applications. Applikationen. Applications. Aplicaciones LOCKING MECHANISMS FOR WASHROOMS
E s e m p i d i i m p i e g o Applikationen Aplicaciones LOCKING MECHANISMS FOR WASHROOMS THE REQUIREMENTS In hospitals, washrooms are often accessible from two rooms. It is therefore, important to ensure
More information1 Door closers. Door closers Technical information. The global leader in door opening solutions.
1 Door closers Door closers Technical information The global leader in door opening solutions. ASSA ABLOY Baltic AS Main office: Valdeku 132 Tallinn 112 Estonia Tel. +372 655 9101 Fax +372 655 9100 info@assaabloy.ee
More informationGâches électriques. Elektro-Türöffner. Electric strikes. Cerraderos eléctricos ATP RIM-TYPE STRIKE MULTIFIX A06
Gâches électriques A p r i p o r t a e l e t t r i c i Elektro-Türöffner Electric strikes Cerraderos eléctricos ATP RIM-TYPE STRIKE MULTIFIX A06 ATP RIM-TYPE STRIKE MULTIFIX A06 MultiFix model range 14A06,
More informationDICTATOR Hold-Open Systems for Hazardous Areas
DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought
More informationFor Standard Applications
Electric strikes For Standard Applications About us. Whatever you want to secure, protect, maintain - we have the technology you require. Breaking new grounds, implementing new technologies, developing
More informationTS 93. Cam action door closer system in Contur Design
TS 9 Cam action door closer system in Contur Design VERSATILE AND ELEGANT The TS 9 cam action door closer system provides a high-quality architectural solution for all project application requirements.
More informationUniversal operator - easy to install, reliable in operation
Universal operator - easy to install, reliable in operation As a powerful fully automatic electro-hydraulic swing door operator, the DORMA ED 200 is suitable both for standard doors and also for large
More informationAll by design. ASSA ABLOY Door Controls
All by design. ASSA ABLOY Door Controls Designed to work for you ASSA ABLOY door controls span three technologies that cover everything you could want from a door closer: from unique features that enhance
More informationDC200 Rack and pinion door closer with link arm
114 Door closers Rack and pinion door closer with link arm ASSA ABLOY Certified in compliance with EN 114, size 2-4 Suitable for fire and smoke protection doors For single action doors up to 10 mm wide
More informationGEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM
GEZE SAFETY TECHNOLOGY GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM Title and cover photo: GEZE GmbH GEZE SecuLogic RWS TABLE OF CONTENTS GEZE emergency
More informationABLOY FIRE DOOR CLOSING SYSTEMS
FIRE DOOR CLOSING SYSTEMS Maximum security An ASSA ABLOY Group brand FIREDOOR CLOSING SYSTEMS Maximum security and easy access ABLOY high security products are well known and highly respected all over
More informationWorld Strike 77 series Adjustable. The whole range for quick and easy installation. ASSA ABLOY, the global leader in door opening solutions
World Strike 77 series Adjustable The whole range for quick and easy installation. ASSA ABLOY, the global leader in door opening solutions 3 World Strike Your Benefits The New World Strike Quick and easy
More informationECO ETS Electromotive drive
ECO ETS Electromotive drive 1 ETS 73 - System highlights 1. Force - up to 250 kg / EN 7 The ECO ETS has a strong power unit that safely opens and closes door leafs up to 250 kg in weight and up to 1.600
More informationUV Flame Supervision System
7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running
More informationHold-open magnets DORMA
Hold-open magnets DOA DOA Hold-open magnets A modular system for fire and smoke doors Setting new standards for hold-open magnets DOA s new range of hold-open magnets provides the perfect complement to
More information01_TT_TST_04_61_GB.qxd :30 Uhr Seite 4. Door Closers and Door Control Systems
0_TT_TST_04_6_GB.qxd 5.08.004 9:0 Uhr Seite 4 Door Closers and Door Control Systems 4 0_TT_TST_04_6_GB.qxd 5.08.004 9:0 Uhr Seite 5 4 6 Concealed cam action door closers with slide channel Cam action and
More informationCam action door closer system DORMA TS 93
Cam action door closer system DORMA TS 93 reddot design award winner 200 DORMA TS 93 Cam action door closer system DORMA TS 93 Cam action door closer system TS 93 G-SR-EMR Versatile and elegant The TS
More informationRegulatory Reform (Fire Safety) Order 2005
Regulatory Reform (Fire Safety) Order 2005 This document has been prepared by ASDMA (Architectural & Specialist Door Manufacturers Association) to provide for guidance for Responsible Persons in respect
More informationAirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation
mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning
More informationDORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut
DORMA Free Swing and Hold-open Solutions for Fire Doors An alternative to Fire door keep shut Permanently closed fire doors can present an obstacle to building occupants, particularly on circulation routes,
More informationFCP 320/FCH 320 Conventional Automatic Fire Detectors
Fire Alarm Systems FCP 320/FCH 320 Conventional Automatic Fire Detectors FCP 320/FCH 320 Conventional Automatic Fire Detectors High reliability of detection thanks to evaluation electronics Active adjustment
More informationGEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM
GEZE SAFETY TECHNOLOGY GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM Title and cover photo: GEZE GmbH GEZE SecuLogic RWS TABLE OF CONTENTS GEZE emergency
More informationUse this guide to assist you when completing the Evacuation scheme application form.
Guide EVACUATION SCHEME APPLICATION ABOUT THIS GUIDE Use this guide to assist you when completing the Evacuation scheme application form. CONTENTS Before you start completing your application Section 1
More informationTS 93. Cam action door closer system in Contur Design
TS 93 Cam action door closer system in Contur Design dormakaba TS 93 Versatile and elegant The TS 93 cam action door closer system provides a high-quality architectural solution for all project application
More informationABLOY DOOR AUTOMATICS Easy access for all types of swing doors
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where opening doors manually would be inconvenient or laborious. Recommended
More informationNEW. TS 98 XEA: Licence to close. Slide channel door closer TS 98 XEA
NEW TS 98 XEA: Licence to close Slide channel door closer TS 98 XEA Expertise and experience from the production of more than 100 million door closers has gone into the development of the TS 98 XEA. That
More informationDC300 Rack and pinion door closer with link arm
Rack and pinion door closer with link arm ASSA ABLOY Rack and pinion closer with link arm L190 Certified in compliance with EN 114, size 3-6 Suitable for fire and smoke protection doors For single action
More informationSMARTair SOLUTIONS GUIDE. Providing complete specifications utilising ABLOY SMARTair. Page 1
SMARTair SOLUTIONS GUIDE Providing complete specifications utilising ABLOY SMARTair Page 1 Table of Contents Solutions Standard Internal Applications - Standard Handle Set Page 4 - Standard Wall Reader
More information½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E
Schneider-Electric 2014EAV56178-0102/15 en Getting to know the smoke detector Scope of supply ARGUS Smoke Detector Single Operating instructions Art. no. MEG5470-2119 Accessories Sealing pin for ARGUS
More informationFDC/ -B. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO
ECO FDC/ -B Product information SYSTEM TECHNOLOGY FOR THE DOOR FDC / -B Product characteristics FDC FDC- B Closing force Size acc. to EN (continuously adjustable) 3 6 4 6 Door width acc. to EN Dimensions
More informationSecurity Door Closer Safe and secure by design. ASSA ABLOY Door Controls
Security Door Closer Safe and secure by design ASSA ABLOY Door Controls The challenge: How can you upgrade doors in your building while preserving fire safety certification? Buildings evolve. A new occupant
More informationHAHN CQ LINE. Electromagnetic door holding systems
HAHN CQ LINE Electromagnetic door holding systems Kendrion - Industrial Magnetic Systems We develop solutions! Kendrion develops, manufactures and markets highquality electromagnetic systems and components
More informationConductive Leakage detectors of the Leckstar range
Conductive Leakage detectors of the Leckstar range with electrode and relay Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466 Lambrecht (Germany) Tel. +49 6325 188-01 Fax +49 6325 6396 www.jola-info.de
More informationOptical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator
TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who
More informationLFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR
7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or
More informationDC340 Rack and pinion door closer with guide rail or link arm
128 Door closers Rack and pinion door closer with guide rail or link arm ASSA ABLOY Available with heigth-adjustable guide rail G195 or standard guide rail G193 Certified in compliance with EN1154, size
More informationABLOY DOOR CLOSERS Excatly the right choice
DOOR CLOSERS Excatly the right choice DOOR CLOSERS Superior performance and reliability ABLOY high security products are known and highly respected all over the world. Every item in our wide product range
More informationOperating Instructions
Operating Instructions TEKA Cartmaster Type PF-W 1, PF-W 2 TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0)
More informationTest Unit GTL 100 for Fire Detectors
Test Unit GTL 100 for Fire Detectors Description and Operation Manual Zertifiziertes QM System Nach DIN EN ISO 9001 Description and Operation Manual Table of Contents 1. Instructions 1.1 General 1.2 Standards
More informationLFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02
7 783 ISO 9001 DETACTOGYR Flame Safeguard Series 02 The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil
More informationContents. Best Trusted and Rated Quality Products. PX-1 Stand-Alone Smoke Alarm. PX-1C Radiolink Smoke Alarm. PX-AR Alarm Relay
Product Line PX-I Stand-Alone Smoke Alarm PX- IC Radiolink Smoke Alarm PX-AR Alarm Relay PX-iP Wi-Fi Smoke Alarm System Pyrexx Web-App Colouresque Variety Accessories EN Contents 04 05 06 07 08 09 10 11
More informationEMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be
EMLC Academy Trust Fire Safety Policy 2017/19 Every child deserves to be the best they can be 1 Scope: EMLC Academy Trust & Academies within the Trust Version: 2 Filename: EMLC Academy Trust Fire Safety
More informationLine Smoke Detector LRMX
Line Smoke Detector LRMX Motorized detector head User-friendly commissioning via automatic selfadjustment Disturbance-protected operation via automatic electromechanical tracking of the detector head during
More informationABLOY DOOR AUTOMATICS Easy access for all types of swing doors
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where opening doors manually would be inconvenient or laborious. Recommended
More informationUpdated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations
Updated to include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations WHICH DORMA DOOR CONTROL? INTRODUCTION There are two main
More informationSpark Extinguishing Systems. Extinguish BEFORE Ignition. Fire Protection. Measuring Technology. Service. Fagus-GreCon Greten GmbH & Co.
Fagus-GreCon Greten GmbH & Co. KG P.O. Box 1243 D-31042 Alfeld-Hanover Phone +49(0)5181-79-0 Fax +49(0)5181-79-229 E-Mail sales@grecon.com www.grecon.com Extinguish BEFORE Ignition Fire Protection Measuring
More informationAirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation
mfh systems modern floor heating AirUnit Decentralised domestic ventilation Operating manual List of contents, Operating manual Page 1. General information... 02 2. Device description... 03 3. Adjustment
More informationABLOY DOOR CLOSERS Exactly the right choice
DOOR CLOSERS Exactly the right choice An ASSA ABLOY Group brand DOOR CLOSERS Superior performance and reliability ABLOY high security products are known and highly respected all over the world. Every item
More informationNotice. Approval number: Z Scope of validity By: 08 January 2013 to: 01 November 2017
Notice of the amendment and supplementation to the general building inspectorate approval dated 25 October 2012 Approval body for building products and types of building Civil Engineering Test Agency An
More informationDC300 Rack and pinion door closer with link arm
Rack and pinion door closer with link arm ASSA ABLOY Rack and pinion closer with link arm L190 Certified in compliance with EN 114, size 3-6 Suitable for fire and smoke protection doors For single action
More informationHART XL High Sensitivity Smoke Detection
High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.
More informationABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE
ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that
More informationFire Door Control Solutions
Fire Door Control Solutions Contents Fire Door Control Solutions Smoke Detectors Pages 07.003.00-07.018.00 Power Packs Control of Signals Ex-Proof Hold-Open Systems Pages 07.019.00-07.030.00 Electromagnets
More informationORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P
ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions
More informationJANSEN BRANDSCHUTZ. Special solutions - Protection without limits
JANSEN BRANDSCHUTZ Special solutions - Protection without limits Recess shutters Special sizes Corner fire protection Fire protection via semi-circular lifting door JANSEN BRANDSCHUTZ Special solutions
More informationM-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH
EN M-Sens 2 Operating Instructions Online-Moisture Meter for Solids SWR engineering Messtechnik GmbH CONTENTS Page 1. System Overview......................................................................
More informationMBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.
24V 24V PME PME CM DM SM DM WM Reset Reset Emergency power control unit GB Installation instructions 1 Table of contents 1 Symbols and illustrations...3 2 Product liability...3 3 Safety instructions...3
More informationFire PROtec. Manual for automatic Fire Curtains. copyright by SIMON RWA Systeme GmbH Passau
Fire PROtec Manual for automatic Fire Curtains Edition B /2007 All information are subject to technical changes, errors excepted Contents 1. System Description Page 3-4 1.1 General 3 1.2 Fire curtain sizes
More informationSERIES 4000 AUTO GATE MANUAL
SERIES 4000 AUTO GATE MANUAL Website: www.turnstilesecurity.com Page 1 of 27 Table of Contents 1.0 Warranty... 4 2.0 Safety... 5 2.1 Designated Use... 5 2.2 Areas of Application... 5 2.3 Warning Notes...
More informationComfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W
Comfort Ceiling Fan Coil System INDULVENT ec NEW Draught-free ambient air distribution with cooling capacity up to 2600 W Low sound power levels Only electrical, cooling water and condensate connections
More informationPluggit iconvent Decentralized residential ventilation with heat recovery Operating and installation instructions
git iconvent Decentralized residential ventilation with heat recovery Operating and installation instructions www.pluggit.com The technology makes the difference. Innovations of git with an added value
More informationED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR
ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk
More informationEM Hold-open magnets
Hold-open magnets dormakaba modular system for fire and smoke doors setting new standards for hold-open magnets dormakaba s new range of hold-open magnets provides the perfect complement to a technically
More informationACS-30-EU-EMDR- 10-MOD
ACS-30-EU-EMDR- 10-MOD MULTI-APPLICATION HEAT TRACING CONTROL AND MONITORING IN COMMERCIAL AND RESIDENTIAL BUILDINGS ROOF & GUTTER DE-ICING SENSOR MODULE TECHNICAL INFORMATION DESCRIPTION The nvent RAYCHEM
More informationConventional Fire Detection
SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct
More informationDFA 127. record DFA 127 automatic drive system for swing doors. record your global partner for entrance solutions
record your global partner for entrance solutions record DFA 127 automatic drive system for swing doors your global partner for entrance solutions DFA 127 your global partner for entrance solutions DFA
More informationMR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION
DOCUMENT CONTROL NUMBER / MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION 1. INTRODUCTION The MR300 range of optical smoke detectors forms part of the M300 series of plug-in
More informationhighline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10
highline WINDOW CONTROLS INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM SVCS-1 * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10 CERTIFICATE OF COMPLIANCE SVCS-1 We the undersigned
More informationElectronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21
Electronic Standard Devices Annunciator Relay MR and MRE MR 2 and MRE 2 The products described in this brochure are intended for industrial use and meet the requirements laid down by the EU directive 7
More informationHART XL High Sensitivity Smoke Detection
High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in
More informationInstallation and Operating Instructions
ELECTRICALLY OPERATED FOLDING STAIRS Installation and Operating Instructions Premier Loft Ladders ltd Registered Office: 2 Dawson Drive, Trimley St Mary, Felixstowe, Suffolk. IP11 0YW Registered in England
More informationMeeting the requirements of the Equality Act & Fire regulations. Which Door Control?
Meeting the requirements of the Equality Act & Fire regulations Which Door Control? Introduction There are two main considerations in specifying door controls: Does it meet the requirements of the Equality
More informationInstruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!
Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de
More informationInstallation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro
Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2
More informationNon-contacting guards
General information Non-contacting guards www.schmersal.com Dr. Peter Kocher Definition In the introduction of the standard EN 61496-1 [1], which is relevant for non-contacting guards, such guards, as
More informationHANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S
FACTORY AUTOMATION HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S Certification Type Tested Inhalt / Content / Sommaire / Indice Deutsch......................................................... 3 English.........................................................
More informationIDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80
IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...
More informationOperation Manual. Control TJ-HRC
Operation Manual Control TJ-HRC for NET Heat Exchangers TJ-HRC-0218 1 Subject to changes in design and scope of delivery as well as further technical developments. Original operation manual, Neue Energie-Technik
More information2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC
2CKA001473B9007 19.05.2017 System Manual Busch-Infoline Handicapped toilet signal set 1510 UC-... -101 Table of contents Table of contents 1 Notes on the instruction manual... 3 2 Safety... 4 2.1 Information
More informationM-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP
EN M-Sens 2 Operating Instructions Online moisture measurement for solids SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP CONTENTS Page 1. System overview.............................................
More informationSCHMIDT LED Measured Value Display MD Instructions for Use
SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...
More informationVentilator insert Silvento V... Installation directions - Please pass on to the user -
Ventilator insert Silvento V... Installation directions - Please pass on to the user - Contents: Notes on these installation instructions Safety precautions Technical specifications, waste disposal Parts
More informationSilvento concealed variant clamped-ventilator - Replaces Skalar-; Skalar-V...; Skalar-2V... - Installation directions - Please pass on to the user -
Silvento concealed variant clamped-ventilator - Replaces Skalar-; Skalar-V...; Skalar-2V... - Installation directions - Please pass on to the user - Contents: Notes on these installation instructions Safety
More informationSpeed and Frequency Seite 1 von 7
Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.
More informationXenex Conventional Fire Detection & Alarm System
SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector
More informationDATASHEET. Burner control unit FDA 601x
EN 298 / EN 230 2012 19 PCB 100x160mm 3HE/8TE socket DIN 41612 2-channel microprocessor controlled program air valve control for heating / cooling preventilation continuous operation with ionisation intermittent
More informationGEZE DOOR TECHNOLOGY GEZE TS 1500 / TS 2000 / SYSTEM TS 4000 OVERHEAD DOOR CLOSERS WITH LINK ARM BEWEGUNG MIT SYSTEM
GEZE DOOR TECHNOLOGY OVERHEAD DOOR CLOSERS WITH LINK ARM BEWEGUNG MIT SYSTEM Cover photo: Robert Les, photo on page 2: GEZE GmbH Overhea oor closers with link arm CONTENTS Overview table 4 Technics 6 Prouct
More informationMultifunctional Gate Box MGB. More than safety.
Multifunctional Gate Box MGB More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 98. Around the world the Swabian specialists
More informationOperating instructions for the radio heat detector GS412
Operating instructions for the radio heat detector GS412 Index 1. Safety instructions... 3 2. Suitable and unsuitable locations... 3 2.1 Radio heat detectors should be installed in the following rooms:...
More informationXGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more
EN XGUARD-0/-5 LASER SCANNERS for industrial doors XGUARD-0: max. detection range of 9.9 m x 9.9 m XGUARD-5: max. detection range of 5.0 m x 5.0 m User s Guide for product version 0600 and more SAFETY
More informationOperating Manual. English. Refrigerators for chemicals KRC 50 KRC 180
English Operating Manual Refrigerators for chemicals KRC 50 KRC 180 1.951.6610-V1 12/12 JULABO GmbH 77960 Seelbach / Germany Tel. +49 (0) 7823 / 51-0 Fax +49 (0) 7823 / 24 91 info@julabo.de www.julabo.de
More informationSENSOR SOLUTIONS FOR DOORS
SENSOR SOLUTIONS FOR DOORS Application Overview Safety Light Curtain RAY-LG Pedestrian Door Switch ENTRYSENSE Non-Contact Edge RAY-NC Opto-Electronic Safety Edge OPTOEDGE Photo Eyes RAYTECTOR, RAY-M, RAY-RT,
More informationSchueco Fire and Smoke Protection Systems
Schueco Fire and Smoke Protection Systems Green Technology for the Blue Planet Clean Energy from Solar and Windows 02 Schueco Fire and Smoke Protection Systems Fire and Smoke Protection Systems Schueco
More informationSENSOR SOLUTIONS FOR DOORS
SENSOR SOLUTIONS FOR DOORS Application Overview Safety Light Curtain RAY-LG Pedestrian Door Switch ENTRYSENSE Pre-Traveling Light Barrier OPTOGUARD Opto-Electronic Safety Edge OPTOEDGE Photo Eyes RAYTECTOR,
More informationINFRARED MODULATED BARRIERS
INFRARED MODULATED BARRIERS riello elettronica group INFRARED BARRIERS WITH ADJUSTABLE LENSES FULL FULL SYNCRO POWER SUPPLY 12/24 Vac-dc MAXIMUM RANGE UNDER IN CONDITIONS 15 METRES CONFORMS TO THE SAFETY
More informationOperating instructions
MA00929301 09/2015 Operating instructions ED10429002 ESYLUX GmbH An der Strusbek 40 22926 Ahrensburg Germany info@esylux.com www.esylux.com 1 Table of contents 1 Using the manual 8 2 Safety instructions
More informationInstructions for Use
T-1321 e 6.12.13 Translation of the original instructions for use Instructions for Use For Automatic Sliding Doors with Drive imotion 2202 Sliding Door Drive imotion 2202.A Sliding Door Drive imotion 2301
More informationShort Term Accommodations Fire Code Requirements
Short Term Accommodations Fire Code Requirements 1 Foreward The following is a comprehensive reference to Retrofit 9.3 of Division B of the Ontario Fire Code (OFC). Retrofit provisions were developed to
More informationDANGER DETECTORS 2016 RANGE
ABUS UK www.abus.com DANGER DETECTORS 2016 RANGE Robust monitoring for underestimated risks: smoke and danger detectors Q4, 2015 CONTENTS EVERYTHING AT A GLANCE DANGER DETECTORS 2016 RANGE In this catalogue,
More informationMonitoring Devices 11/1
11/4 Introduction 11/6 5TE5 8 light indicators 11/7 4AC3 0, 4AC3 1 bells, buzzers 11/7 5TT3 46 fault signaling units 11/8 7LQ2 1, 5TT3 3 dusk switches 11/9 7LQ2 0 temperature controllers 11/9 5TT3 170
More information