OH110, OP110, HI110, HI112 Detectoare automate, Seria 110
|
|
- Sabina Merritt
- 6 years ago
- Views:
Transcription
1 OH110, OP110, HI110, HI112 Detectoare automate, Seria 110 Cerberus FIT Pentru linii de detectie colective si conventionale Procesarea semnalului cu algoritmi de detectie Seturi de parametri selectabile Indicare cu 3 LED-uri Compensare de drift Monitorizarea interna a defectelor Indicator de defect
2 Caracteristici OH110 detector de fum multi-senzor De mediu Procesare ecologica Materiale reciclabile Materiale electronice si sintetice usor de separat si recuperat Caracteristici Rezistent la factori de mediu si interferente cum ar fi praful, fibre, insecte, umiditate, temperaturi extreme, campuri electromagnetice, vapori corozivi sau vibratii Insensibil la impact, protejare cu tamper Electronica protejata, inalta calitate a componentelor. Indicator de alarma (AI), integrat in detector vizibil 360 Se pot conecta pana la 2 tipuri de indicatori externi de tipul FDAI91/FDAI92/FDAI93 conectabili per detector. Acelasi tip de soclu pentru toate tipurile de detectoare Optional Dispozitiv de blocare a detectoarelor impotriva furtului tip LP720 Placuta de etichetare FDBZ291 Element de etanseitate pentru soclu de detector RS720 Micro terminal DBZ1190-AA ( mm 2 ) Terminal de conexiune DBZ1190-AB ( mm 2 ) Detectorul de fum multi-senzor este alcatuit din: Detector Masca de praf pentru protejarea detectorului in timpul lucrarilor de constructie Functioneaza pe principiul imprastierii luminii sesizate cu un senzor optic, inainte de imprastiere. Camera optoelectronica de mostre de particule nu permite luminii exterioare sa interfereze, ajutand la detectarea optima a particulelor de fum, mai inchise sau mai deschise la culoare. Un senzor suplimentar de temperatura mareste imunitatea la fenomenele de interferenta Comportament de detectie selectabil prin doua seturi de parametri Setul de parametri 1: Senzitiv Setul de parametri 2: Robust Imunitate impotriva alarmelor false Pentru detectarea inceniilor cu flacara cauzate de combustia materialelor lichide si solide, ca si a incendiilor mocnite Pentru o detectare rapida a focului intr-un mediu ostil cu fenomene inselatoare 2
3 OP110 detector optic de fum Detectorul de fum este alcatuit din: Detector Masca de praf pentru protejarea detectorului in timpul lucrarilor de constructie Functioneaza pe principiul imprastierii luminii sesizate cu un senzor optic, inainte de imprastiere. Camera optoelectronica de mostre de particule nu permite luminii exterioare sa interfereze, ajutand la detectarea optima a particulelor de fum, mai inchise sau mai deschise la culoare. Comportament de detectie selectabil prin doua seturi de parametri Setul de parametri 1: Standard Setul de parametri 2: Sensitive Pentru detectia flacarilor generatoare de fum si a focurilor mocnite HI110 Detector de temperatura (RoR) Detectorul de fum este alcatuit din: Detector Echipat cu un senzor de temperatura Pentru cerinte inalte Diverse moduri de raspuns la cresterea temperaturii lenta sau rapida, ca si profunzimea temperaturii Setul de parametri A1R Pentru zonele cu un nivel ridicat de praf, murdărie sau umezeală, care pot conduce la activarea alarmelor false a detectoarelor de fum HI112 detector de temperarura (static) Detectorul de fum este alcatuit din: Detector Echipat cu un senzor de temperatura Masoara temperatura ambientala, cand temperatura maxima este depasita detectorul transmite un semnal de alarma centralei Comportament de detectie selectabil prin doua seturi de parametri Setul de parametri 1: A2S Setul de parametri 2: B Pentru zonele cu un nivel ridicat de murdărie sau fluctuatii de temperatura, care pot conduce la activarea alarmelor false a detectoarelor de fum 3
4 Soclu DB110 (Setul de parametri 1) Soclu conventional standard pentru toate tipurile de detectoare din seria 110 Selecteaza setul de parametri 1 in detectoare pentru cablare ingropata pentru cablare aparenta, diametrul cablului de maxim 8 mm Soclul de detector DB110D (Setul de parametri 1) pentru BS5839, Part 1 Soclu conventional cu dioda pentru toate tipurile de detectoare din seria 110 Selecteaza setul de parametri 1 in detectoare pentru cablare ingropata pentru cablare aparenta, diametrul cablului de maxim 8 mm Soclul de detector DB110R (Setul de parametri 2) Soclu conventional cu rezistenta pentru setarea parametrilor si dioda de continuitate pentru toate tipurile de detectoare din seria 110 Selecteaza setul de parametri 2 in detectoare pentru cablare ingropata pentru cablare aparenta, diametrul cablului de maxim 8 mm Soclul de detector DB110RD (Setul de parametri 2) pentru BS5839, Part 1 Soclu conventional cu rezistenta pentru setarea parametrilor pentru toate tipurile de detectoare din seria 110 Selecteaza setul de parametri 2 in detectoare pentru cablare ingropata pentru cablare aparenta, diametrul cablului de maxim 8 mm Atasament de soclu BA720 Pentru montarea tevilor de cabluri (max. 20 mm) si a paturilor de cabluri aparente (max. 25 mm x 15 mm) Detectorul este fixat cu ajutorul unui arc de blocare. Siemens 4
5 5 Instalare Instalare simpla Soclu universal cu Doua decupaturi laterale pentru cabluri pozate aparent cu diametrul max. Ø8 mm Decupatura mare pe spate pentru conectarea simpla a cablurilor Gaurile de montaj foarte mari permit refolosirea gaurilor de suruburi de la alte sisteme Terminale de conexiuni pentru cabluri cu diametrul de max 2,5 mm 2 Loc pentru terminale auxiliare 2x DBZ1190-AA si 2x DBZ1190-AB Loc pentru terminale auxiliare DBZ1190-AA, DBZ1190-AB Terminale de conexiune pentru linia de detectie si IA extern Loc pentru intrarea cablului AI 6 1a 1b Terminale de conexiune pentru linia de detectie si IA extern Loc pentru suruburi min. 40 mm pana la max. 90 mm LP720 Dispozitiv de inchidere pentru detectoare Indicatorul de alarma (IA) este in mijlocul detectorului, nu este nevoie de aliniere. Pentru protectia impotriva furtului Pin filetat M3 x 12 mm Cheie hehagonala 5
6 5 FDBZ291 Placa pentru eticheta Pentru udentificarea adresei dispozitivului. Se foloseste doar fara sigiliul de etanseizare RS720 RS720 Sigiliu de etanseizare pentru soclu Pentru marirea gradului de protectie DBZ1190-AA Microterminal, DBZ1190-AB Teerminal de conexiuni Pentru conductoare de max. 0,5 mm 2 Pentru conductoare de max. 2,5 mm 2 Punct de suport pentru conexiuni in T, indicatoare de alarma externe (IA) sau ecranul cablului Loc pentru max. 2 terminale aditionale 6 1a 1b 6 Siemens
7 Dimensiunea detectorului cu soclu OH110 OP110 HI110/HI112 Date tehnice OH110 OP110 HI110 / HI112 Tensiunea de operare DC V DC V DC V Curentul de operare (in repaus) Max. 100µA Max. 100µA Max. 100µA Indicator de alarma extern fara soclul cu sirena Numar indicatoare cenectabile Temperatura de operare C C C (HI110) C (HI112, A2S) C (HI112, B) Temperatura de stocare C C C Umiditate (este permisa condensarea 96 % rel. 96 % rel. 96 % rel. pe termen scurt Protocol de comunicare Colectiv/Conventional Colectiv/Conventional Colectiv/Conventional Culoare weiss, ~RAL 9010 weiss, ~RAL 9010 weiss, ~RAL 9010 Categoria de protectie EN60529 / IEC529 Cu sigiliul de etanseizare pentru IP40 IP42 IP40 IP42 IP40 IP42 soclu RS720 Normen CEA4021, EN 54-7 EN 54-7 EN 54-5 Aprobari VdS LPCB G cerere G cerere Standarde QS Standard Siemens SN G / G cerere 7
8 Detalii de comanda Tip Nr. Articol Nume Greutate OH110 S54372-F11-A1 Detector de fum multisenzor - colectiv 0,144 kg OP110 S54372-F4-A1 Detector de fum optic - colectiv 0,138 kg HI110 S54372-F9-A1 Detector de temperatura (diferential) - colectiv 0,130 kg HI112 S54372-F10-A1 Detector de temperatura (static) - colectiv 0,130 kg DB110 S54372-F5-A1 Soclu - Colectiv 0,052 kg DB110D S54372-F6-A1 Soclu pentru BS5839, Pertea 1 0,100 kg DB110R S54372-F7-A1 Soclu Colectiv 0,052 kg DB110RD S54372-F8-A1 Soclu pentru BS5839, Partea 1 0,100 kg Zubehör LP720 S54319-F9-A1 Dispozitiv de inchidere pentru detectoare (2 chei hexagonale, 100 pini hexagonali) 0,040 kg FDBZ291 A5Q Placa pentru eticheta (10x) 0,034 kg FDAI91 S54370-F9-A1 Indicator alarma, varianta pentru tocul usii kg FDAI92 S54370-F3-A1 Indicator alarma, varianta pentru suprafete 0,050 kg FDAI93 S54370-F5-A1 Indicator alarma, varianta ingropata 0,010 kg BA720 S54319-F20-A1 Atasament de soclu 0,100 kg RS720 S54319-F8-A1 Sigiliu de etanseizare pentru soclu (10x) 0,014 kg DBZ1190-AA BPZ: Microterminal 0, ,5 mm 2 0,001 kg DBZ1190-AB BPZ: Terminal de conexiuni 1,0... 2,5 mm 2 0,007 kg Pentru detalii verificati documentul numarul A6V Siemens SRL Bucuresti Infrastructura si Orase Divizia Tehnologie Pentru Cladiiri Bld. Preciziei nr.24, West Gate Park, H3 sector 6, Ro , Bucuresti, Romania tel: Copyright by Siemens Switzerland Ltd Data and design subject to change without notice. Supply subject to availability. Document no. A6V _e_de_-- Manual FD720 Edition Section 2
DBS721, DBS729 Sounder interbase, Sounder beacon interbase
DBS721, DBS729 Sounder interbase, Sounder beacon interbase For the automatic addressable detector bus C-NET Cerberus PRO Sounder interbase DBS721 and sounder beacon interbase DBS729 11 selectable tones,
More informationOH720, OP720, HI720, HI722
Cerberus PRO OH720, OP720, HI720, HI722 Automatic fire detectors For the automatically addressable detector bus C-NET The ideal fire detector for every application Signal processing with detection algorithms
More informationOOH740, OOHC740 Automatic fire detectors
OOH740, OOHC740 Automatic fire detectors ASAtechnology TM For the automatic addressable detector bus C-NET Collective / Conventional (OOH740 only) Cerberus PRO Signal processing with ASAtechnology TM Event-controlled
More informationOH110, OP110, HI110 Automatic fire detectors
OH110, OP110, HI110 Automatic fire detectors For collective and conventional detector lines Signal processing with detector algorithms Selectable parameter sets 3 color LED indication Drift compensation
More informationFDS229-R / FDS229-A Alarm sounder with supplementary optical indication
FDS229-R / FDS229-A Alarm sounder with supplementary optical indication For the automatic addressable detector bus C-NET and FDnet Cerberus PRO Sinteso Alarm sounder with 11 tonalities selectable, 2 activation
More informationOOH740, OOHC740. Cerberus PRO. Automatic fire detectors
Cerberus PRO OOH740, OOHC740 Automatic fire detectors ASAtechnology For the automatically addressable detector bus C-NET collective / conventional (OOH740 only) Signal processing with ASAtechnology Event-controlled
More informationFDCL221-M Multi line separator module
FDCL221-M Multi line separator module addressable (FDnet/C-NET) Sinteso TM Cerberus PRO Automatic module with several line separators Creation of T taps (stub lines) in the FDnet/C-NET Operation of the
More informationManual call points. Sinteso / Cerberus PRO FDM225, FDM226
Sinteso / Cerberus PRO Manual call points FDM225, FDM226 Manual call points with direct activation for the FDnet/C-NET automatic addressable detector bus Manual call points for addressed Sinteso FS20 and
More informationMulti line separator module
Sinteso Cerberus PRO Multi line separator module FDCL221-M Multi line separator module, addressed (FDnet/C-NET) Automatic module with several separate line separators Formation of stub lines (T-branches)
More informationFDBZ290 Air sampling smoke detection kit
FDBZ290 Air sampling smoke detection kit Sinteso Cerberus PRO Reliable monitoring for smoke of supply air, exhaust air and recirculation ducts of air conditioning and ventilation systems Suitable for air
More informationDC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules
DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules AnalogPLUS AlgoRex DC1130 Series Thanks to its robust construction, the input/output modules can be used in both dry and dusty / wet areas
More informationFDBZ290 Air sampling smoke detection kit
FDBZ290 Air sampling smoke detection kit Sinteso Cerberus PRO Reliable monitoring for smoke of supply air, exhaust air and recirculation ducts of air conditioning and ventilation systems Suitable for air
More informationDC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules
DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules Interactive AlgoRex DC1150 Series Thanks to its robust construction, the line modules can be used in both dry and dusty / wet areas Housing
More informationManual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)
Sinteso Cerberus PRO Manual call point FDM223H, FDM224H 'Heavy Duty' manual call point addressed (FDnet/C-NET) Manual call points for addressed Sinteso FS20 and Cerberus PRO FS720 fire detection systems
More informationInput module, input/output modules
Sinteso / Cerberus PRO Input module, input/output modules FDCI222, FDCIO222, FDCIO224 Input module and input/output modules for the automatically addressed detector line Input module FDCI222: Four monitored
More informationOH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual
OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual 17.10.2011 Control Products and Systems Technical specifications and availability subject to change without notice. 2008-2011 Copyright
More informationInput module, input/output module
Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input
More informationFDCIO223 (ES 45) Transponder
FDCIO223 (ES 45) Transponder Addressed (FDnet/C-NET) Sinteso Cerberus PRO 2 monitored inputs/outputs, which can optionally be used as a detector line (collective Siemens/Cerberus, Synova 600, or collective
More informationDC1192 Input /Output module
DC1192 Input /Output module Interactive, AnalogPLUS/SynoLOOP, collective/synoline600 AlgoRex Synova In-/output module suitable for collective fire detection system as detection line coupler interactive
More information13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba
Cerberus PRO Cerberus FIT Interbases DBS721, DBS728, DBS729 Sounder interbase, sounder beacon interbase, sounder interbase with supplementary optical indication for the automatically addressable detector
More informationOutput module (230 V)
Cerberus FIT Output module (30 V) FCA109-Z1 Output module for use in monitored output lines Output with potential-free relay contacts for controlling fire ventilators, air conditioning systems, elevators,
More informationDB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories
DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories interactive, AnalogPLUS/SynoLOOP, collective/synoline600 AlgoRex Synova TM Base made of impact and scratch-proof plastic Screw less terminals
More informationOH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines
Automatic Fire Detector For collective and conventional detector lines Signal processing with detector algorithms Selectable parameter sets 3 colour LED indication Drift compensation Internal fault monitoring
More informationDM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button
DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button collective/synoline600 AlgoRex Synova Manual call point to all fire detection system control
More informationFC724 Fire control panel
FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as
More informationFDOOT241-9, FDOOT241-A, FDO241, FDT241
Sinteso S-LINE FDOOT241-9, FDOOT241-A, FDO241, FDT241 Automatic fire detectors For the automatically addressed detector bus FDnet The ideal fire detector for every application Line separators for uninterrupted
More informationFC722 Fire control panel
FC722 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as
More informationOOH740-A9-Ex Multisensor fire detector
OOH740-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled
More informationFDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM
Sinteso Cerberus PRO Cerberus FIT FDF241-9 Flame detector Flame detector addressed or collective, ASAtechnology TM Reliable detection using three infrared sensors and ASAtechnology (indoor and outdoor
More informationFC723 Fire control panel
FC723 Fire control panel FS720 series (IP5) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 756 addresses Processes
More informationDM1131 / DM1133 / DM1134 Manual call points
DM1131 / DM1133 / DM1134 Manual call points AnalogPLUS/SynoLOOP AlgoRex Synova Manual call points to the fire detection system AnalogPLUS/SynoLOOP Manual call point DM1131 with direct operation Manual
More informationFC724 Fire control panel
FC724 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as
More informationInterbases. Sinteso FDSB221, FDSB228, FDSB229
Sinteso Interbases FDSB221, FDSB228, FDSB229 Sounder interbase, sounder beacon interbase, sounder interbase with supplementary optical indication for the automatically addressable detector bus FDnet Addressed
More informationOOH740-A9-Ex Multi-sensor fire detector
OOH740-A9-Ex Multi-sensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled
More informationDT1101A / DT1102A / DO110xA Automatic fire detectors
DT1101A / DT1102A / DO110xA Automatic fire detectors collective/synoline600 AlgoRex Synova High degree of reliability and stability Compatible with all control units with collective/synoline600 detector
More informationFDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system
FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system Addressed (FDnet) Sinteso Full integration into FS20, SIGMASYS, and AlgoRex fire detection systems Simultaneous operation
More informationFDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8
Sinteso S-LINE FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8 Multisensor fire detectors Multi-sensor fire detector for gradual modernization with ASAtechnology For the modernization of
More informationASA linear smoke detector
Sinteso / Cerberus PRO ASA linear smoke detector FDL241-9 Linear smoke detector, used addressed or collectively, ASAtechnology TM Reliable smoke detection in large spaces (indoor application) Detection
More informationFDOOT221, FDO221, FDT221
Sinteso C-LINE FDOOT221, FDO221, FDT221 Automatic fire detectors For the automatically addressed detector bus FDnet The ideal fire detector for every application Signal processing with detection algorithms
More informationDOW1171 / DCW1151 Radio fire detection system
DOW1171 / DCW1151 Radio fire detection system Interactive AlgoRex Complete integration in the interactive fire detection system CS1140 Simultaneous operation of wired and wireless fire detectors New possibilities
More informationFDCL221-Ex Line adapter (Ex)
FDCL221-Ex Line adapter (Ex) Addressed (FDnet-Ex/C-NET-Ex) For operating FDnet-Ex/C-NET-Ex peripheral devices in potentially explosive areas Sinteso Cerberus PRO Electrical isolation of Ex and non-ex lines
More informationDF1101-Ex Infrared flame detector
DF1101-Ex Infrared flame detector Collective/SynoLINE 600 for explosion-hazard areas of zones 1 and 2 AlgoRex Synova Sinteso Cerberus PRO For inside and outside applications Triple-sensor evaluation Detection
More informationFDCL221 Line separator
FDCL221 Line separator Technical manual Fire Safety & Security Products Technical specifications and availability subject to change without notice. 2004-2009 Copyright Siemens, Inc. We reserve all rights
More informationFDOOT241-A9-Ex Multisensor fire detector
FDOOT241-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Sinteso Collective Signal processing with ASAtechnology Multiple protocol detector (collective/fdnet-ex) Event-controlled
More informationFC722 Fire control panel
FC722 Fire control panel Series FS720 (MPXS) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as
More informationMimic display driver, LED ribbon cable
Sinteso / Cerberus PRO Mimic display driver, LED ribbon cable FT2001-A1, F50F410 FDnet/C-NET mimic display driver and LED ribbon cable for the fire detection systems Sinteso FS20 and Cerberus PRO FS720.
More informationSistem electronic multi-circuit de distribuţie electrică, control şi monitorizare a sistemelor de însoţitori electrici, cu montare pe panou.
Sistem electronic multi-circuit de distribuţie electrică, control şi monitorizare a sistemelor de însoţitori electrici, cu montare pe panou CONDUCTĂ DE CABLU Module Card Rack COMUTATOR PRINCIPAL 800 mm
More informationSWING radio fire detection system
Sinteso / Cerberus PRO SWING radio fire detection system FDCW241, FDOOT271, FDM273, FDM275, FDM275(F), FXS2061 SWING radio fire detection system Multihop mesh technology Full integration into the fire
More informationDM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex
DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex Interactive, for explosion-hazard area of zones 1 and 2 AlgoRex Manual call point to the interactive fire detection system with microprocessor,
More informationFC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel
FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel Synova Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches, punch cards, etc. unnecessary
More informationDF1151-Ex Infrared flame detector
DF1151-Ex Infrared flame detector Interactive, for explosion-hazard areas of zones 1 and 2 AlgoRex For inside and outside applications Triple-sensor evaluation Detection in various wavelengths Microprocessor-controlled
More informationFC330A-ECO Auto-addressing analogue 1-Loop fire detection panel
FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic
More informationFC2020 Fire control panel
FC2020 Fire control panel Series FS20 (MP4.0) Sinteso Compact, prefabricated, microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as stand-alone
More informationFire control panels FC726 FC726-XA
Fire control panels FC726 FC726-XA Modular, pre-confectioned, microprocessor-controlled fire control panel for up to max. 1512 device addresses Integrated, user-friendly operating unit Detection and automatic
More informationSynova TM product catalog.
Synova product catalog Synova TM product catalog. Fire protection products and accessories. Siemens Switzerland Ltd Building Technologies Group International Headquarters Gubelstrasse 22 CH-6301 Zug Tel
More informationRaport IFLA Global Vision, Madrid Delegat RalucaTRIFU. #iflaglobalvision
Raport IFLA Global Vision, Madrid 2017 Delegat RalucaTRIFU ÎMPREUNĂ CREĂM VIITORUL! DISCUȚII GLOBALE VIZIUNEA IFLA 2017 IFLA a lansat IFLA Global Vision Obiectiv Crearea unui forum de discuții globale
More informationRadio fire detection system
OEM Radio fire detection system FDOOT271-O, FDM273-O, FDM275-O Radio fire detection system Multihop mesh technology High transmission reliability thanks to the use of independent communication paths transmission
More informationFire control panels FC360
Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses
More informationFDL241-9 Linear smoke detector Mounting Commissioning
FDL241-9 Linear smoke detector Mounting Commissioning 2014-06-27 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. 2011-2014
More informationData încetării prezumţiei de conformitate a standardului înlocuit. Indicativ standard Titlu standard Standard înlocuit
03.01.2018 Standarde române care adoptă standarde europene armonizate privind echipamente terminale de telecomunicaţii şi recunoaşterea mutuală a conformităţii acestora sub incidenţa directivei RTTE 2014/53/EU
More informationTHERMAL ANALYSIS OF TANKLESS HEATING SYSTEM
BULETINUL INSTITUTULUI POLITEHNIC DIN IAŞI Publicat de Universitatea Tehnică Gheorghe Asachi din Iaşi Volumul 64 (68), Numărul 2, 2018 Secţia ELECTROTEHNICĂ. ENERGETICĂ. ELECTRONICĂ THERMAL ANALYSIS OF
More informationXC10 combined fire detection and extinguishing control
XC10 combined fire detection and extinguishing control Planning Tool for multi-sector applications Compact panels for fire detection and extinguishing control Protecting people and assets, business processes
More informationCONSIDERATII PRIVIND INTRODUCEREA UNUI SISTEM DE STINGERE A INCENDIULUI IN STATIILE ELECTRICE DE TRANSFORMARE
CONSIDERATII PRIVIND INTRODUCEREA UNUI SISTEM DE STINGERE A INCENDIULUI IN STATIILE ELECTRICE DE TRANSFORMARE CONSIDERATION ON FIRE SUPPRESSION SYSTEM IN SUBSTATIONS Vasile TABACARU Cezar CRISTIAN SC FDFEE
More informationSiemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation
Sinteso Cerberus PRO FDA241, FDA221 ASD Aspirating smoke detector Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Patented technology Early
More informationXC10 combined fire detection and extinguishing control
XC10 combined fire detection and extinguishing control Planning Tool for single-sector applications Compact panels for fire detection and extinguishing control Protecting people and assets, business processes
More informationOperating and Maintenance Instructions
Instrucțiuni de Exploatare și Întreținere Operating and Maintenance Instructions Model / Models: X-CYCLONE C 2-7 Comanda-Nr. Order No. Din 05/ 2013 As of 05/ 2013 www.facebook.com/reven.ro Producător /
More informationDSB-F0901ELH-VKW DSB-F1201ELH-VKW DSB-F1801ELH-VKW DSB-F2401ELH-VKW
DSB-F0901ELH-VKW DSB-F1201ELH-VKW DSB-F1801ELH-VKW DSB-F2401ELH-VKW 6 Please scan the QR code to download the latest App software. The latest App software integrated air conditioner, dehumidifier and Portable
More informationCerberus FIT conventional system
Cerberus FIT conventional system Combining intelligent signal processing and easy installation for reliable fire detection and alarming www.siemens.com/cerberus-fit Reliable, intelligent and cost-efficient
More informationFDCI221, FDCIO221 Input module, input/output module Technical Manual
FDCI221, FDCIO221 Input module, input/output module Technical Manual 2012-09-30 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without
More informationFDA241, FDA221 Siemens ASD
FDA241, FDA221 Siemens ASD Patented Technology Sinteso TM Cerberus PRO Compatible with the Siemens FDnet/C-NET loops (requires FDCC221S option) Advanced dual Wavelength optical detection (Blue & Infra-red)
More informationFDS229 Alarm sounder with supplementary optical indication Technical Manual
FDS229 Alarm sounder with supplementary optical indication Technical Manual 2014-02-10 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change
More informationCentrala detectie incendiu analog adresbila IRIS
Centrala detectie incendiu analog adresbila IRIS Manual instalare si programare CUPRINS 1. INTRODUCERE... 5 1.1 Descriere Generala... 5 1.2 Specificatii Generale... 5 1.2.1 Specificatii tehnice generale...
More informationXC10 Extinguishing control panels
XC10 Extinguishing control panels Market package 2.1 Advanced control panels for detection and alarming as well as for the activation of the extinguishing process Microprocessor-controlled fire detection
More informationFDCW241 Radio gateway Mounting
FDCW241 Radio gateway Mounting 2017-01-05 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal, reproduction, dissemination
More informationFDBZ290 Air sampling smoke detection kit Technical Manual
FDBZ290 Air sampling smoke detection kit Technical Manual 2015-12-17 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal,
More informationDryer User Manual Uscător Manual de utilizare DU 7133 GA _EN/
Dryer User Manual Uscător Manual de utilizare DU 7133 GA0 2960311090_EN/210415.1617 Please read this user manual first! Dear ustomer, Thank you for prefering a Beko product. We hope that your product which
More informationSistem de alarma wireless PNI Safe House PG300
Sistem de alarma wireless PNI Safe House PG300 Manual de utilizare Pentru a utiliza sistemul de alarma in mod corect va recomandam sa cititi complet acest manual. Configurarea si instalarea acestui sistem
More informationData încetării prezumţiei de conformitate a standardului înlocuit. Indicativ standard Titlu standard Standard înlocuit
23.05.2017 Standarde române care adoptă standarde europene armonizate privind echipamente terminale de telecomunicaţii şi recunoaşterea mutuală a conformităţii acestora sub incidenţa directivei RTTE 2014/53/EU
More informationFC2040. Fire control panel. Sinteso. FS20 series, MP6
FC2040 Sinteso Fire control panel FS20 series, MP6 Compact, pre-assembled, microprocessor-controlled fire control panel with integrated operating unit for up to 504 addresses Fire control panel can be
More informationEUROPEAN DIGITAL CITY BASED ON THE SVN CONCEPT ORASUL DIGITAL EUROPEAN DUPA CONCEPTUL SVN
EUROPEAN DIGITAL CITY BASED ON THE SVN CONCEPT ORASUL DIGITAL EUROPEAN DUPA CONCEPTUL SVN Dorin FLOREA Mayor of Tirgu Mures City Vice-President of the Romanian Association of Municipalities Elected since
More informationFire & Security Products. Siemens Building Technologies Group
Fire & Security Products Siemens Building Technologies Group . 1 Brief overview.................................................... 1 1.1 Characteristics....................................................
More informationFD20 Sinteso Detector system
FD20 Sinteso Detector system Equipment overview CPS Fire Safety Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability.
More informationTermostat cu ecran digital
Termostat cu ecran digital Modele: VS35W și VS35B MANUAL DE UTILIZARE/INSTALARE Contents Conținut Conținut cutie Introducere Conformitatea produsului Instalarea Ghidul utilizatorului Parametrii de setare
More information9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE
Cerberus PRO Marine Fire and Detection Equipment s FH-2071-UM, BP-62 and USCG-HPLATE Cerberus PRO Fire Safety Products ARCHITECT AND ENGINEER SPECIFICATIONS Marine equipment is used with Cerberus PRO 252-point
More informationFC700A Fire detection control unit
FC700A Fire detection control unit Synova 4-16 Loop analogue addressable control panel 128 devices per loop (SynoLOOP) and up to 1000 devices per panel Up to 24 collective lines for Synova TM 600 serie
More informationHOTTY. POMPE DE CALDURA AER APA PENTRU EXTERIOR Temperaturi inalte - Eficienta ridicata
HOTTY POMPE DE CALDURA AER APA PENTRU EXTERIOR Temperaturi inalte - Eficienta ridicata FRE ON R7c Pf = 7,6 21,7 kw Pt = 9,1 24,8 kw Mod. 031 081 Temperatura maxima apa 60 C CALOR SRL - Str. Progresului
More informationFDM273 Radio manual call point Mounting
FDM273 Radio manual call point Mounting 2016-11-28 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal, reproduction,
More informationEvolution Analogue Addressable Fire System
Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards
More informationFORENSIC ERGONOMICS IN ROMANIA Forensic Ergonomics consultants are usually involved in cases where it is suspected that damages, injury or death resul
International Journal of Criminal Investigation Volume 1 Issue 3 109-113 FORENSIC ERGONOMICS IN ROMANIA Abstract Octavian CIOBANU, Gr.T.Popa University of Medicine and Pharmacy, Iași (oct.ciobanu@gmail.com)
More informationFS720 Fire detection system (marine) Technical Manual
FS720 Fire detection system (marine) Technical Manual 2016-05-10 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal,
More informationME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems
Electronic Alarm Indication Systems ME 3011 compact Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment 2 Table of Contents Contents Page System
More informationTest units and accessories
Cerberus PRO Test units and accessories FDUL221, DX791, RE6, REF8, REF8-S, REF8-C, RE8, RE8-S, RE8-C, RE7T, RE8ST, RE8STCO, RE8-CO, RE7T-x, RE10, FDUM29x, FDLU291, LE3, StabexHF Test units to test detectors
More informationRules for Intruder Alarm Systems
Rules for Intruder Alarm Systems Opening detectors (Magnetic contacts) Part 1: Requirements VdS 2120en 03/96 (03) Subject 44 1 General; 2 Terms and definitions; 3 Classification 1 General 1.1 Scope These
More informationStandard Devices. Electronic Alarm Indication Systems. ME 3011b
Standard Devices Electronic Alarm Indication Systems ME 3011b Before connecting and powering this device, please read carefully the manual, and refer to it whenever you have any doubts. This brochure is
More informationFDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points
FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points Technical manual Building Technologies Fire Safety & Security Products Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design
More informationSOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon
SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon alarm devices For fire detector and extinguishing systems Loud alarm signal clearly recognizable as a danger signal even in noisy environments
More informationORGANISMUL NAȚIONAL DE STANDARDIZARE.
ORGANISMUL NAȚIONAL DE STANDARDIZARE www.asro.ro Definiție formulată în cadrul ITU A smart sustainable city is an innovative city that uses information and communication technologies (ICTs) and other means
More informationSystem 800 Addressable Fire Detection & Alarm System
SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools
More informationFire control panel for modernization
Sinteso Fire control panel for modernization FC2030 Modular, pre-assembled fire control panel with integrated, user-friendly operating unit for gradual migration to Sinteso. Fire control panel for a maximum
More informationFOCSANI. Emmanuel Crivat URBAN PLANNING & MODERNIZATION URBANISM SI MODERNIZARE
FOCSANI Emmanuel Crivat URBAN PLANNING & MODERNIZATION URBANISM SI MODERNIZARE Schita de IDEI - The draft of ideas Base théorique La théorie de la signification 2 Schita de IDEI - The draft of ideas Care
More information