Product Catalogue. Safety Equipment. Capacitive Voltage Detectors and Voltage Detection Systems

Size: px
Start display at page:

Download "Product Catalogue. Safety Equipment. Capacitive Voltage Detectors and Voltage Detection Systems"

Transcription

1 Product Catalogue Safety Equipment Capacitive Voltage Detectors and Voltage Detection Systems 6

2 Your Partner for Safety Equipment Since 1928 the name ARCUS equals quality and reliability in cable connections and safety products. The ARCUS ELEKTROTECHNIK ALOIS SCHIFFMANN GMBH is a highly specialised industrial enterprise in which high-quality products are designed and produced for the worldwide market. Our product range includes: Connectors and tools for underground cables Overhead line clamps Earthing and short circuiting devices with cables and bars Lance earthing devices for outdoor switchgear up to 80 ka/0.5 s and 63 ka/1 s High voltage detectors for nominal voltages up to 420 kv Detectors and phase comparators for encapsulated switchgear Compression material and compression tools Devices for current tapping and power supply Always in the centre of our activities: Our clients. Our top aim is their complete and long-term satisfaction! Highly qualified and motivated employees in our company in Munich and in our sales offices are the main condition for a successful conversion of customers' requirements. During the long history of our company we have always accepted some complex requirements of our customers as a challenge to be met. Cooperations with our business partners in technical projects which have in many cases resulted in products with exposed position on the world market. Technical know-how and the latest production techniques to insure long-term quality and reliability of our products. Availability by phone: For queries concerning products and delivery time, and to place an order by phone, we are available as follows: 49 (0)89/ Monday - Thursday: 8:00 am-12:00 noon and 12:30 pm-16:00 pm Friday: 8:00 am-12:00 noon Information concerning this catalogue: All rights reserved for copying of any kind. All dimensions and pictures are not binding. We permanently strive to improve products and reserve the right to change design, dimensions or material.

3 Contents General List of type numbers 4 Foreword 5 Introduction 6 Technical information voltage detectors 8 Technical information voltage detecting systems 13 Product overview 15 Voltage detectors for railway networks, overhead lines, and substations ARCUSBASIC 6-20 kv for overhead lines and substations Indoor use 16 Outdoor use 17 ARCUSDETECT M up to 36 kv for overhead lines and switchgear Indoor use 18 Outdoor use 19 ARCUSDETECT M for railway energy lines and substations 20 ARCUSDETECT M for railway energy lines 21 ARCUSDETECT M for contact wires 22 ARCUSDETECT H for traction current lines 23 ARCUSDETECT H up to 420 kv for overhead lines and substations outdoor use 24 ARCUSDISTANT III kv for overhead lines (non-contact voltage detector) 25 Accessories Handle extensions (threaded) 26 Extensions for contact electrode (threaded) 27 Fork contacts (threaded) 28 Additional extensions (threaded) 28 Wall holders 29 Carrying cases 30 Carrying bags 31 List of voltage detectors and allocation of accessories 32 Voltage detecting systems for encapsulated switchgear ARCUSPHASE 1x VDS 34 ARCUSPHASE 2x VDS & UPC 36 ARCUSPHASE - case sets 38 ARCUSPHASE - accessories 40 Periodic testing and repair 41 Questionnaire for voltage detectors 42 3

4 List of Type Numbers Type Number Page Type Number Page Type Number Page General

5 Introduction Dear reader! General The assessment of electrical installations and equipment with respect to their voltage status (voltage present or not) is always required when working on or with such installations, or in the vicinity of them. Following the result of such an assessment are usually a number of operations, for instance to earth and short circuit in those cases when absence of voltage has been determined. Consequently it is essential to have a clear and correct indication of voltage status. Absence of voltage can be determined in different ways. Besides firmly installed measuring or signaling devices, there is also the possibility to conclude on the voltage status from the switch position of earthing switches. Yet according to EN , absence of voltage is to be determined as close to the working site as possible. So usually a portable device for determination of absence of voltage is indispensable. Such portable detectors need to be as handy as possible, and simple to operate, considering that absence of voltage needs to be determined on all phases at the working site. 5

6 Introduction General Difficult handling or slow signalisation may lead the user to abandon the procedure, especially when under time pressure. In the worst case this may have lethal consequences. On the other hand, the detectors themselves must not endanger the user. Their application needs to be safe even under disadvantageous conditions, such as heavy rainfall, or on the cross arm of a 380 kv overhead line pylon. In the course of many decades, a number of different portable devices for determination of absence of voltage, in brief voltage detectors, have been developed. Depending on type of electric installation (outdoor substation, indoor installation, GIS, overhead line, etc.), different detectors are used which have one feature in common: they give fast and safe indication about absence or presence of voltage in the installation. ARCUS has arranged voltage detectors in different groups, based on the intended usage of the detectors. We mainly distinguish between: ARCUSBASIC: for outdoor and indoor installations 6-20 kv ARCUSDETECT M: for outdoor and indoor installations up to 36 kv ARCUSDETECT H: for outdoor installations up to 420 kv ARCUSDISTANT (non-contact voltage detector): for overhead lines kv ARCUSPHASE: for encapsulated switchgear up to 52 kv 6

7 Introduction General All these capacitive voltage detectors are adapted to their usage in an optimal way, and are configured to suit the individual customer requirements. Customised variations with different transport length, type of indication, or specific threshold values, in many cases can be considered. Also special requests, such as a different colour for the insulating rod, retrofit contact electrodes, or handle extensions are often possible to fulfil. This catalogue will give you an overview about our programme of high voltage detectors and accessories. We have arranged these products in the mentioned different groups to facilitate identification. All important details are listed in a table and supported by pictures. In case of uncertainties how to find a product or how to select a suitable one, please contact us. You will find our contact details on the backside of this catalogue. For a non-binding offer, please use our new questionnaire on pages 42 and following. ARCUS not only offers a vast range of high voltage detectors and accessories, but furthermore will be pleased to provide expertise and support in selecting the suitable products. This service is a matter of course for us! 7

8 Technical Information Voltage Detectors Product overview voltage detectors ARCUSBASIC: Low-cost construction for indoor and outdoor substations 6-20 kv General ARCUSDETECT M: Robust and ergonomic construction for railway networks, overhead lines, and indoor and outdoor substations up to 36 kv ARCUSDETECT H: Robust and easy-to-operate construction for railway networks, overhead lines, and outdoor substations up to 420 kv ARCUSDISTANT: User-friendly construction for overhead lines kv (non-contact voltage detector) O not available X basic version S special design ARCUSBASIC ARCUSDETECT M ARCUSDETECT H ARCUSDISTANT IEC X X X O Nominal voltage [kv] 6-20 Up to 36 Up to Single voltage detector X X X S Voltage range detector O X X X Frequency: 50 Hz X X X X Frequency: 16.7 Hz O S S S Visual indication X S O O Audible indication O O O X Visual and audible indication O X X O Indoor use X X S O Outdoor use X X X X Self-test X X X X Threaded fork contact (page 28) Threaded extension for contact electrode (page 27) Threaded additional extension (page 28) Threaded handle extension (page 26) S S X O O S O O O S O O O S S O Tubular bag (page 31) S S X S Carrying case (page 30) S S S S Wall holder (page 29) S S S S 8

9 Technical Information Voltage Detectors Overview of models ARCUSBASIC: 1-part For indoor substations 6-20 kv (50 Hz) General 2-part For indoor substations 6-20 kv (50 Hz) 2-part For outdoor substations 6-20 kv (50 Hz) ARCUSDETECT M: 2-part For indoor substations up to 36 kv (50 Hz) 2-part For outdoor substations up to 36 kv (50 Hz) 2-part For feeder lines and outdoor substations up to 36 kv (16.7 Hz) 2-part and 6-part For outdoor contact wire installations (16.7 Hz) 9

10 Technical Information Voltage Detectors Overview of models (continued) ARCUSDETECT H: General For overhead lines and outdoor substations up to 420 kv (50 Hz) 3-part and 4-part For railway networks up to 132 kv (16.7 Hz) 3-part and 4-part Usage in factory-assembled, type-tested switchgear The high voltage detector can be used in factory-assembled, type-tested switchgear only under specific conditions. One needs to clarify with the manufacturer of such switchgear, if and where the high voltage detector is permitted to be used. Usage in IT-Networks (insulated networks) This voltage detector is not suitable for use in IT-Networks. Construction and function The high voltage detector is a portable device to determine presence or absence of operating voltage at the installation part to be tested. It has a one-part or multiple-part design, with a handle section LH, an insulating element Li, and a head part with insertion depth Ai (see pict.1 on page 11). The handle section LH is the area in which the high voltage detector is to be held during voltage test. The insulating element Li is located between the hand guard (4) and the limit mark (red ring) (2). It gives the user the required protective distance and sufficient insulation towards the installation part to be tested for absence of voltage. The insertion depth Ai is the part of the high voltage detector between limit mark (red ring) (2) and contact electrode (1). It reduces the influence of interference fields on the indicator (3). From contact electrode (1) in direction of handle, the high voltage detector may be inserted up to the limit mark (red ring) (2) between earthed or live installation parts, or may contact them. 10

11 Technical Information Voltage Detectors 1 Indication signal: Signalisation is effected by LEDs for visual indication and/or by a piezo sound element for audible indication (see pict.2) LH Li Ai LO Single voltage and voltage range detectors: Beside our standard single voltage detectors, in addition our programme includes detectors for voltage ranges. This way one can cover a defined nominal voltage range with only one detector without the need to switch between single nominal voltages. Nominal frequency: ARCUS Voltage Detectors are designed for use in 50 Hz and 16.7 Hz power networks. Climatic conditions: Climatic category: N (normal) Temperature range: -25 up to 55 C Humidity: % Design and interference fields: The voltage detector measures the electric displacement current which is generated by two different potentials in one system. Thereby applies, the higher the potentials are at a distance, the higher the displacement current. This means, when the contact electrode has contact with a live part, the indicator part is to be positioned to have as large a distance as possible towards other live parts. Particularly in substations, but also on overhead line towers with complicated arrangements, the complex field configuration requires an extension of the detector s contact electrode until the above mentioned actual situation applies. General Pict.1 This construction carries the category "S" for substations, and features a clearly higher safety of indication than the short construction L. For safety reasons we have decided to only offer detectors with category S, for substations as well as for overhead lines. Easy battery exchange: ARCUS voltage detectors are designed for fast and easy exchange of used batteries. Pict.2 ARCUSDETECT M: Visual and audible indication Simple operation: Use of light-weight components and multiple-part insulating rods secure safe and simple handling in substations, railway applications, and on pylons. 11

12 Technical Information Voltage Detectors Self-test device General According to EN , voltage detectors are to be tested immediately before use, and if possible also after use. In all ARCUS detectors you will find a built-in self-testing device also called function check. Within the electronic circuit it tests all components. In case components or soldering points are not in good order, the self-testing device will recognise it and indicate the fault. Also the battery charge condition is included in the self-test. The self-testing device, whether built-in or as a separate device, needs to be able to test all electric circuits, including energy source and function of indication. In case it will not be possible to test all electric circuits, every limitation is to be mentioned in the instruction of use. These electric circuits must be produced with highest reliability. With a built-in self-testing device, the detector is to indicate its condition ready or not ready. IEC demands that all electric circuits which are not included in the self-test are mentioned. In our detectors, for safety reasons all electric circuits are self-tested without any limitation, even the contact electrode extensions including the contact electrode itself - up to 420 kv. Earthing arrangements Important for the correct indication of the detector is its area of application and the related earthing arrangement of the power network. We distinguish between one- and three-phase a.c.networks (three-phase current networks). Earthing arrangements: Symbols Simplified picture Net system effectively single-side isolated neutral 1-phase system (rail energy lines and contact wires) effectively centre-isolated neutral 1-phase system (traction current lines) effectively star point isolated neutral 3-phase system (overhead lines and substations) 12

13 Technical Information Voltage Detecting Systems Product overview voltage detecting systems according to IEC ARCUSPHASE: ARCUSPHASE is designed to test encapsulated switchgear with rated voltage of up to 52 kv and a nominal frequency of 50 Hz. General ARCUSPHASE 1x VDS 1) is a 1-polar voltage detector to IEC , with visual indication. ARCUSPHASE 2x VDS & UPC 2) is a 2-polar voltage detector and phase comparator to IEC , with visual indication. O not available X basic version ARCUSPHASE 1x VDS ARCUSPHASE 2x VDS & UPC IEC X X Nominal voltage [kv] Up to 52 Up to 52 Frequency: 50 Hz X X Visual indication X X Self-test X X Single-pole voltage detection X X Two-pole voltage detection O X Measurement of phase angle O X Measurement of frequency X X Test of interface (periodic testing) X X Expandable to various interfaces X X OLED colour display X X Indoor use X X Outdoor use X X With batteries X X With recharger set for rechargeable batteries X X 1) VDS=Voltage Detecting System 2) UPC=Universal Phase Comparator 13

14 Technical Information Voltage Detecting Systems ARCUSPHASE: Construction and function General With ARCUSPHASE professional electricians have at hand a universal measuring device for capacitive interfaces on highest technical level. With its integrated self-testing device which tests all relevant circuit elements including measuring lines, the ARCUSPHASE presents the ultimate safety for the user. A high-contrast display produced with OLED-technology facilitates reading of measurement results. For better distinction of limit values of interface currents, ARCUSPHASE provides two super-bright LED per measuring channel. In practical use, ARCUS- PHASE convinces with extremely simple and intuitive handling. Technical data Nominal frequency: 50 Hz Threshold value: 4.5 V at 2.0 MOhm Environmental temperature: -20 C up to 60 C Protection class: IP 54 Usage: Indoor and outdoor Phase balance: Phase angle -20 up to 20 (ARCUSPHASE 2x VDS & UPC) Model with batteries: 3x Alkali Mangan size LR6 or AA or 3x Lithium size FR6 or AA Model with rechargeable batteries : with recharger set for rechargeable batteries Standard: IEC Dimensions: 210 x 95 x 40 mm Weight: 300 g (excluding measuring lines) Highlights & details Precise measurement of current, phase angle (ARCUSPHASE 2x VDS & UPC), and frequency Accuracy of current measurement: 100 na Accuracy of frequency measurement: 0.1 Hz Accuracy of phase angle: 0.5 (ARCUSPHASE 2x VDS & UPC) Test of interface with real effective value of interface current according to IEC Integrated self-testing device for all system-relevant groups of components including measuring lines Automatic and manual selection of measuring functions CB-function: CB stands for Communication Back and returns to the user information about interface and phase angle over the display Simple and comfortable configuration by means of a clear menu navigation and extra-large pressure keys Large high-contrast OLED colour display with additional LED-signalisation Detachable measuring lines Ergonomic housing to IP54 Protector for rough conditions of use CE-Conformity Declaration: EMV-Directive 2004/108/EG ROHS-compliant Extension of measurement range with suitable measurement adaptors possible on all usual interface systems (LR, HR, LRM, LRP) High operating safety by use of high-quality components Reliable interface test OLED colour display with LED-signalisation Simple menu configuration 14

15 Product Overview Voltage detectors for railway systems, overhead lines, and switchgear ARCUSBASIC For indoor and outdoor use 6-20 kv Page 16 ff. General ARCUSDETECT M For indoor and outdoor use up to 36 kv Page 18 ff. ARCUSDETECT H For outdoor use up to 420 kv Page 23 ff. ARCUSDISTANT III For overhead lines kv Page 25 ff. Accessories Extensions for contact electrode, fork contacts, additional extensions, handle extensions Page 26 ff. Wall holders, cases, bags Page 29 ff. Voltage detection systems for encapsulated switchgear ARCUSPHASE 1x VDS 1-polar voltage detector up to a rated voltage of 52 kv, according to IEC Page 34 ff. ARCUSPHASE 2x VDS & UPC 2-polar voltage detector and phase comparator up to a rated voltage of 52 kv, according to IEC Page 36 ff. 15

16 ARCUSBASIC 6-20 kv for Use on Overhead Lines and in Substations Indoor Use According to IEC Technical information: Nominal frequency: 50 Hz Indication signal: visual (2 LED / 1x green, 1x red) Climatic category: N (normal) Temperature range: -25 up to 55 C Humidity: 20 to 96 % Design: S Power supply: 9-volt battery; alkaline Voltage Detector Accessories: Carrying bags and wall holders page 29 ff. Ø 24.2 Ø 32.7 Ai Li LH LO Type overview U n [kv] f [Hz] Net system LO Ai Li LH Transport length n-parts Bag (1) Type number ) not included effectively star point isolated neutral 3-phase system 16

17 ARCUSBASIC 6-20 kv for Use on Overhead Lines and in Substations Outdoor Use According to IEC Technical information: Nominal frequency: 50 Hz Indication signal: visual (2 LED / 1x green, 1x red), Climatic category: N (normal) Temperature range: -25 up to 55 C Humidity: 20 to 96 % Design: S Power supply: 9-volt battery; alkaline Accessories: Carrying bags and wall holders see page 29 ff. Ø 24.2 Ø 24.2 Voltage Detector Ai Li LH LO Type overview U n [kv] f [Hz] Net system LO Ai Li LH Transport length n-parts Bag (1) Type number ) not included effectively star point isolated neutral 3-phase system 17

18 ARCUSDETECT M up to 36 kv for Overhead Lines and Switchgear Indoor Use According to IEC Technical information: Nominal frequency: 50 Hz Indication signal: visual (2 LED / 1x green, 1x red), audible (piezo oscillator) Climatic category: N (normal) Temperature range: -25 up to 55 C Humidity: 20 to 96 % Design: S Power supply: 9-volt battery; lithium Voltage Detector Accessories: Fork contacts page 28 Additional extensions page 28 Extensions for contact electrode page 27 Handle extensions page 26 Carrying bags, cases and wall holders page 29 ff. Ø 21 Ø 24.2 Ai Li LH LO Type overview U n [kv] f [Hz] Single voltage detector Net system LO Ai Li LH Transport length n-parts Bag (1) Type number Voltage range detector ) not included effectively star point isolated neutral 3-phase system 18

19 ARCUSDETECT M up to 36 kv for Overhead Lines and Switchgear Outdoor Use According to IEC Technical information: Nominal frequency: 50 Hz Indication signal: visual (2 LED / 1x green, 1x red), audible (piezo oscillator) Climatic category: N (normal) Temperature range: -25 up to 55 C Humidity: 20 to 96 % Design: S Power supply: 9-volt battery; lithium Accessories: Fork contacts page 28 Additional extensions page 28 Extensions for contact electrode page 27 Handle extensions page 26 Carrying bags, cases and wall holders page 29 ff. Ø 24.2 Voltage Detector Ø 21 Ai Li LH LO Type overview U n [kv] f [Hz] Single voltage detector Net system LO Ai Li LH Transport length n-parts Bag (1) Type number Voltage range detector ) not included effectively star point isolated neutral 3-phase system 19

20 ARCUSDETECT M for Railway Energy Lines and Substations Basically to IEC (frequency 16.7 Hz) (and following DIN VDE V ) Technical information: Nominal frequency: 16.7 Hz Indication signal: visual (2 LED / 1x green, 1x red), audible (piezo oscillator) Climatic category: N (normal) Temperature range: -25 up to 55 C Humidity: 20 to 96 % Design: S Power supply: 9-volt battery; lithium Voltage Detector Accessories: Fork contacts page 28 Additional extensions page 28 Extensions for contact electrode page 27 Handle extensions page 26 Carrying bags, cases and wall holders page 29 ff. Ø 24.2 Ø 21 Ai Li LH LO Type overview U n [kv] f [Hz] Single voltage detector Net system LO Ai Li LH Transport length n-parts Bag (1) Type number Voltage range detector 10, ) not included effectively single-side isolated neutral 1-phase system 20

21 ARCUSDETECT M for Railway Energy Lines Basically to IEC (frequency 16.7 Hz) (and following DIN VDE V ) Technical information: Nominal frequency: 16.7 Hz Indication signal: visual (2 LED / 1x green, 1x red), Climatic category: N (normal) Temperature range: -25 up to 55 C Humidity: 20 to 96 % Design: S Power supply: 9-volt battery; lithium With transport eye for carabiner, with threaded fork contact. Usage: Direct voltage detection from mast or working platform. Accessories: Carrying bags, cases and wall holders page 29 ff. Voltage Detector Ø 21 Ø 24.2 Ai Li LH LO Type overview DB-Material-Nr U n [kv] f [Hz] Net system LO Ai Li LH Transport length n-parts Bag (1) Type number ) not included effectively single-side isolated neutral 1-phase system 21

22 ARCUSDETECT M for Contact Wires Following VDE 0681 part 6 Technical information: Nominal frequency: 16.7 Hz Indication signal: visual (2 LED / 1x green, 1x red), audible (piezo oscillator) Climatic category: N (normal) Temperature range: -25 up to 55 C Humidity: 20 to 96 % Design: S Power supply: 9-volt battery; lithium Voltage Detector Accessories: Carrying bag included. LV Ø 21 Ø 32.7 LI LH LG Type overview U n [kv] f [Hz] Net system LG LV LI LH Transport length n-parts Bag Type number effectively single-side isolated neutral 1-phase system 22

23 ARCUSDETECT H for Traction Current Lines Basically to IEC (frequency 16.7 Hz) and following DIN VDE V Technical information: Nominal frequency: 16.7 Hz Indication signal: visual (2 LED / 1x green, 1x red), audible (piezo oscillator) Climatic category: N (normal) Temperature range: -25 up to 55 C Humidity: 20 to 96 % Design: S Power supply: 9-volt battery; lithium Simple battery exchange without additional tool Including carrying bag and threaded fork contact for overhead lines. Accessories: Fork contacts page 28 Handle extensions page 26 Cases and wall holders page 29 ff. Voltage Detector 4-parts Ø 24 Ø 32.7 Ø 37.7 Ø 43 3-parts Ø 37.7 Ø 24 Ai Ø 32.7 Li LH LO Type overview U n [kv] f [Hz] Single voltage detector Net system LO Ai Li LH Transport length n-parts Bag Type number Voltage range detector effectively centre-isolated neutral 1-phase system effectively single-side isolated neutral 1-phase system 23

24 ARCUSDETECT H up to 420 kv for Overhead Lines and Substations Outdoor Use According to IEC Voltage Detector Technical information: Nominal frequency: 50 Hz Indication signal: visual (2 LED / 1x green, 1x red), audible (piezo oscillator) Climatic category: N (normal) Temperature range: -25 up to 55 C Humidity: 20 to 96 % Design: S Power supply: 9-volt battery; lithium Simple battery exchange without additional tool Including carrying bag and threaded fork contact for overhead lines Accessories:. Handle extensions page 26 Cases and wall holders page 29 ff. 4-parts Ø 24 Ø 32.7 Ø 37.7 Ø 43 3-parts Ø 37.7 Ø 24 Ai Ø 32.7 Li LH LO Type overview U n [kv] f [Hz] Single voltage detector Net system LO Ai Li LH Transport length n-parts Bag Type number Voltage range detector effectively star point isolated neutral 3-phase system

25 ARCUSDISTANT III kv for Overhead Lines (Non-Contact Voltage Detector) Following DIN VDE V ARCUSDISTANT III non-contact voltage detector with audible indication is designed for contactless verification of absence of voltage on high voltage overhead lines, from the crossarm of the tower. Technical information: Nominal frequency: 50 Hz Indication signal: audible (piezo oscillator) Temperature range: -25 up to 55 C Humidity: 20 to 96 % Power supply: 9-volt battery; alkaline Accessories: Carrying bags and wall holders page 29 ff. Voltage Detector max. 120 Ø 24.2 LT LG Li LH Type overview U n [kv] f [Hz] Net system LG LT Li LH Transpor length n-parts Bag 1) Type number ) not included effectively star point isolated neutral 3-phase system effectively centre-isolated neutral 1-phase system 25

26 Handle Extensions (threaded) Technical information: Usage: for ARCUSDETECT M or ARCUSDETECT H Material: tube of synthetic material Threaded connection: on one end Type overview Voltage Detector D effective length for D L Effective length Type number L Technical information: Usage: for ARCUSDETECT M Material: tube of synthetic material Threaded connections: on both ends Type overview D D for D L Effective length Type number effective length L Further models and accessories available upon request 26

27 Extensions for Contact Electrode (threaded) Technical information: Usage: for single voltage detectors series ARCUSDETECT M Material: Test electrode: aluminium alloy Extension: tube of synthetic material Type overview effective length L L Effective length Type number Voltage Detector Technical information: Usage: for single voltage detectors series ARCUSDETECT M Material: Test electrode: aluminium alloy Extension: tube of synthetic material Type overview effective length L L Effective length Type number

28 Fork Contacts and Additional Extensions (threaded) Fork Contact acts Technical information: Usage: for overhead lines, with threaded connection to ARCUSDETECT M and ARCUSDETECT H Fork contact: Aluminium alloy Voltage Detector Type overview L Un [kv] L Type number above 24 kv above 52 kv above 72.5 kv Additional Extensions Technical information: Usage: For indoor switchgear 12 kv, with threaded connection to ARCUSDETECT M Standard: IEC Material: Contact tip: Copper alloy (tin-plated) Insulation (red): Polyolefin Type overview D L Effective length Type number D effective length L 28

29 Wall Holders For storage of high voltage detectors, operating rods, and earthing rods. Easy and fast installation. Wall holders are made of very strong plastic material. Voltage Detector Type number For insulating rods with tube diameter Ø mm Type number For insulating rods with tube diameter Ø mm Type number For insulating rods with tube diameter Ø mm 29

30 Carrying Cases Carrying case for high voltage detectors Basic version: Shell of plastic material Voltage Detector Outside dimensions Type number H W D Carrying case for high voltage detectors Robust model: Shell of rigid plastic material with aluminium frame and foamed inlays Outside dimensions Type number H W D

31 Carrying Bags Tubular bags Design: Polyester, royal blue 2x belt strap black 1 shoulder strap Lid with zipper Transparent pocket inside for instruction for use Dimensions Type number Ø 150x820 long Ø 150x1020 long Ø 150x1100 long Ø 150x1220 long Ø 150x1320 long Ø 150x1420 long Ø 150x1520 long Ø 150x1620 long Ø 150x1720 long Voltage Detector Tubular bag for ARCUSDISTANT III Design: Polyester, royal blue 1 shoulder strap with zipper Type number Bag Design: Tarpaulin, royal blue 2x belt strap black With belt closure Transparent pocket inside for instruction for use Suitable for 2-part high voltage detectors H L Pockets Type number

32 List of Voltage Detectors and Allocation of Accessories Voltage Detector Type Number Type Un [kv] f [Hz] Net System Indoor Use Outdoor Use Application n- Parts Transport Length ARCUSDISTANT III x Overhead Line ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Railway Energy Line ARCUSDETECT M x Contact Wire ARCUSDISTANT III x Overhead Line ARCUSBASIC 6 50 x Overhead Line/Substation ARCUSBASIC x Overhead Line/Substation ARCUSBASIC x Overhead Line/Substation ARCUSBASIC 6 50 x Overhead Line/Substation ARCUSBASIC x Overhead Line/Substation ARCUSBASIC x Overhead Line/Substation ARCUSBASIC 6 50 x Overhead Line/Substation ARCUSBASIC x Overhead Line/Substation ARCUSBASIC x Overhead Line/Substation ARCUSDETECT H x Traction Current Line ARCUSDETECT H x Traction Current Line ARCUSDETECT H x Traction Current Line ARCUSDETECT H x Traction Current Line ARCUSDETECT M x Contact Wire ARCUSDETECT H x Overhead Line/Substation ARCUSDETECT H x Overhead Line/Substation ARCUSDETECT H x Overhead Line/Substation ARCUSDETECT H x Overhead Line/Substation ARCUSDETECT H x Overhead Line/Substation ARCUSDETECT H x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Railway Energy Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M x Railway Energy Line/Substation ARCUSDETECT M x Overhead Line/Substation ARCUSDETECT M 6 50 x Overhead Line/Substation ARCUSDETECT H x Traction Current Line ARCUSDETECT M x Railway Energy Line/Substation ARCUSDETECT H x Overhead Line/Substation ARCUSDETECT M x Railway Energy Line/Substation ARCUSBASIC x Overhead Line/Substation Page effectively centre-isolated neutral 1-phase system effectively single-side isolated neutral 1-phase system 32 effectively star point isolated neutral 3-phase systeme

33 List of Voltage Detectors and Allocation of Accessories Type Number Carrying Bag Page 31 Carrying Case Page 30 Handle Extensions Page 26 Extensions for Contact Electrode Page 27 Fork Contact for Overhead Lines Page 28 Additional Extensions Page , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Included , , Included , , Included , , Included , , Included , , Included , , Included , , Included , , Included , , Included , , Included , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Included , , , , , , , , Included , , , , , Voltage Detector 33

34 ARCUSPHASE 1x VDS According to IEC Safety measuring line with plug for LR-system OLED colour display indication of measurement values LED-signalisation Indication of battery status ON/OFF-button Navigation button clear and simple menu navigation Voltage Detecting Systems Product highlights: Ergonomic housing to IP54 suitable for indoor and outdoor use Exchangeable protector for rough usage conditions 1-polar voltage detector (VDS 1) ) tested to IEC Suitable for rated voltages up to 52 kv / 50 Hz Exact and reliable detection of voltage and frequency Test of interface by measurement of real effective value of interface current Integrated self-testing device OLED colour display with additional LED-signallisation Automatic or manual selection of measuring functions Model with batteries or recharger set for rechargeable batteries Ergonomic housing to IP54 suitable for indoor and outdoor use Exchangeable protector for rough usage conditions Further models and accessories available upon request 1) VDS = Voltage Detecting System 34

35 ARCUSPHASE 1x VDS Connection of safety measuring line through a BNC-coupling and test socket for self-test without interface adaptor. Test sockets for self-test including interface adaptor. Technical data: Voltage Detecting Systems Standard: IEC Nominal frequency: Threshold value: 50 Hz 4.5 V at 2.0 MOhm Environmental temperature: -20 C up to 60 C Protection class: IP 54 Usage: High-contrast OLED colour display: Indication of battery status: Model with batteries Model with recharger set for rechargeable batteries Length of measuring lines: Indoor and outdoor Yes Yes 3x Alkali Mangan size LR6 or AA or 3x Lithium size FR6 or AA 3x NiMH-rechargeable batteries size LR6 or AA Connection of measuring line: LR-system (other systems see page 44) Dimensions: Weight: 2 m 210 x 95 x 40 mm 300 g (without measuring lines) 35

36 ARCUSPHASE 2x VDS & UPC According to IEC Safety measuring line with plug for LR-system OLED colour display indication of measurement values LED-signalisation Indication of battery status ON/OFF-button Navigation button clear and simple menu navigation Voltage Detecting Systems Product highlights: Ergonomic housing to IP54 suitable for indoor and outdoor use Exchangeable protector for rough usage conditions 2-polar voltage detector (VDS 1) ) and phase comparator (UPC 2) ); tested to IEC Suitable for rated voltages up to 52 kv / 50 Hz Exact and reliable detection of voltage and frequency Measurement of phase angle with a basic accuracy of 0.5 Test of interface by measurement of real effective value of interface current Integrated self-testing device OLED colour display with additional LED-signallisation Automatic or manual selection of measuring functions Model with batteries or recharger set for rechargeable batteries Ergonomic housing to IP54 suitable for indoor and outdoor use Exchangeable protector for rough usage conditions Further models and accessories available upon request 1) VDS = Voltage Detecting System 2) UPC = Universal Phase Comparator 36

37 ARCUSPHASE 2x VDS & UPC Simple and safe connection of safety measuring lines through BNC couplings. Test sockets for self-test. Technical data: Voltage Detecting Systems Standard: IEC Nominal frequency: Threshold value: 50 Hz 4.5 V at 2.0 MOhm Environmental temperature: -20 C up to 60 C Protection class: IP 54 Usage: Indoor and outdoor Phase balance: Phase angle: -20 up to 20 High-contrast OLED colour display: Indication of battery status: Model with batteries Model with recharger set for rechargeable batteries Length of measuring lines: Yes Yes 3x Alkali Mangan size LR6 or AA or 3x Lithium size FR6 or AA 3x NiMH-rechargeable batteries size LR6 or AA Connection of measuring line: LR-system (other systems see page 44) Dimensions: Weight: 2 m 210 x 95 x 40 mm 300 g (without measuring lines) 37

38 ARCUSPHASE - Case Sets ARCUSPHASE 1x VDS Set with case with recharger set for rechargeable batteries 1x ARCUSPHASE 1x VDS 1x Measuring line red, for LR-system, 2 m long 1x LRM-LR adaptor for LRM-system, earth and phase line 1x LRP-LR adaptor with plug 4mm and with earth line 1x HR-LR adaptor for HR-system 1x Recharger set for rechargeable batteries 1x Instruction for use for ARCUSPHASE 1x Instruction for use for HR-LR adaptor 1 x Plastic case Voltage Detecting Systems Type number ARCUSPHASE 2x VDS & UPC Set with case with batteries 1x ARCUSPHASE 2x VDS & UPC 1x Measuring line black, for LR-system, 2 m long 1x Measuring line red, for LR-system, 2 m long 2x HR-LR adaptor for HR-system 1x Instruction for use for ARCUSPHASE 1x Instruction for use for HR-LR adaptor 1 x Plastic case Type number

39 ARCUSPHASE - Case Sets ARCUSPHASE 2x VDS & UPC Set with case with recharger set for rechargeable batteries 1x ARCUSPHASE 2x VDS & UPC 1x Measuring line black, for LR-system, 2 m long 1x Measuring line red, for LR-system, 2 m long 2x HR-LR adaptor for HR-system 1x Recharger set for rechargeable batteries 1x Instruction for use for ARCUSPHASE 1x Instruction for use for HR-LR adaptor 1 x Plastic case Type number Voltage Detecting Systems ARCUSPHASE 2x VDS & UPC Set with case with batteries 1x ARCUSPHASE 2x VDS & UPC 1x Measuring line black, for LR-System, 2 m long 1x Measuring line red, for LR-System, 2 m long 2x HR-LR adaptor for HR-system 1x Instruction for use for ARCUSPHASE 1x Instruction for use for HR-LR adapto 1x Carrying bag Type number

40 Accessories for ARCUSPHASE LRM-LR adaptor for LRM-system earth and phase line Type number LRM-LR adaptor for LRM-system phase line only Type number LRM-LR adaptor set for LRM-system 1x Type number x Type number Type number Voltage Detecting Systems LRP-LR adaptor for LRP-system with plug 6 mm and with earth line Type number with plug 4 mm and with earth line Type number LRP-LR adaptor for LRP-system with plug 6 mm Type number with plug 4 mm Type number HR-LR adaptor for HR-system Type number Measuring line red for LR-system, 2 m long Type number Measuring line black for LR-system, 2 m long Type number Recharger set for rechargeable batteries incl. recharger, power supply unit, car adaptor (12 V), instruction for use, excl. rechargeable batteries Type number Plastic case Outer dimensions [WxHxD]: 395 x 295 x 106 mm Type number Carrying bag Outer dimensions [WxHxD]: 250 x 130 x 80 mm Type number Protector Material: Lifoflex Type number

41 Periodic Testing and Repair Periodic testing To insure good functioning of your voltage detectors and voltage detecting systems, and at the same time your own safety and the one of your colleagues, according to product standards periodic tests have to be carried out in regular intervals. As manufacturer of voltage detectors and voltage detecting systems we perform fast and economic periodic testing on your detectors. Following work is included in our periodic testing: Electric and mechanic tests according to product standards Cleaning of detectors Add correct instruction for use Test protocol for each detector Each detector is provided with a sticker showing the date for the next periodic testing Return of detectors Filing of test results for the complete product life time in our company Repair Your detector shows defects? Periodic Testing Our technicians will repair damages on faulty detectors: With competence, reliability, and at fair prices! 41

42 founded 1928 Questionnaire for Voltage Detectors As the basis of a non-binding offer, please fill in this questionnaire as detailed as possible and return by fax, post or . Fax / Post ARCUS ELEKTROTECHNIK Alois Schiffmann GmbH Truderinger Straße Munich info@arcus-schiffmann.com Your contact details Name Company Street Phone First name Department Postal code, place Fax Web Voltage Detectors Application Substations Overhead lines Railway energy installations Traction current lines (off rail track) Railway contact wire... Earthing / Net arrangement star point isolated neutral 3-phase system single-side isolated neutral 1-phase system centre-isolated neutral 1-phase system... Nominal voltage Un... kv Portable Earthing and Safety Equipment Cable Connection Technique High Voltage Detectors Phone Fax Fax Seat of the Company Internet: General General Sales Department Truderinger Straße (0) 89 / (0) 89 / (0) 89 / D Munich info@arcus-schiffmann.com

43 founded 1928 Questionnaire for Voltage Detectors (continued) Frequency f 16.7 Hz 50 Hz 60 Hz Voltage detector ARCUSBASIC (6-20 kv) Outdoor use Indoor use ARCUSDETECT M (3-36 kv) ARCUSDETECT H ( kv) ARCUSDISTANT ( kv) X X Outdoor use Outdoor use Outdoor use Indoor use Total length LG approx.... mm Transport length LT approx.... mm Contact electrode Threaded electrode Fork contacts (accessories) Hook contact (only for railway contact wires) Reference detector model... Special requirements... Special requirements Accessories... Others Required quantity Language of documentation Required delivery time Others Date... Signature... Portable Earthing and Safety Equipment Cable Connection Technique High Voltage Detectors Phone Fax Fax Seat of the Company Internet: General General Sales Department Truderinger Straße (0) 89 / (0) 89 / (0) 89 / D Munich info@arcus-schiffmann.com

44 Catalogues "Safety Equipment" Capacitive Voltage Detectors and Voltage Detection Systems Fully-Insulated and Part-Insulated Earthing and Short Circuiting Devices for Low Voltage Applications Safety Equipment for Railway Systems Phone General 49 (0) 89 / Fax General 49 (0) 89 / Fax Sales Department 49 (0) 89 / Internet info@arcus-schiffmann.com Seat of the Company Truderinger Str. 199 D Munich Layout: Marion Renz Edition: Subject to change without notice Copyright ARCUS Schiffmann

SENTINEL D - Fault Passage Monitoring

SENTINEL D - Fault Passage Monitoring SENTINEL D - Fault Passage Monitoring DIRECTIONAL FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-D range allows locating the fault arisen

More information

SENTINEL A - Fault Passage Indicator

SENTINEL A - Fault Passage Indicator SENTINEL A - Fault Passage Indicator AMPEREMETRIC FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-A range allows locating the fault arisen

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

RAGNAR STÅLSKOG AB INSTRUCTION MANUAL HVDC-H HVDC-L VOLTAGE DETECTOR HVDC-H, HVDC-L 15H11

RAGNAR STÅLSKOG AB INSTRUCTION MANUAL HVDC-H HVDC-L VOLTAGE DETECTOR HVDC-H, HVDC-L 15H11 RAGNAR STÅLSKOG AB INSTRUCTION MANUAL HVDC-H HVDC-L VOLTAGE DETECTOR HVDC-H, HVDC-L 15H11 Attention: Read this instruction manual carefully before using the detector. 1. FUNCTION / USE This device is designed

More information

HIGH VOLTAGE A.C.(50 or 60Hz) CONTACT CAPACITIVE HIGH VOLTAGE DETECTOR

HIGH VOLTAGE A.C.(50 or 60Hz) CONTACT CAPACITIVE HIGH VOLTAGE DETECTOR HIGH VOLTAGE A.C.(50 or 60Hz) CONTACT CAPACITIVE HIGH VOLTAGE DETECTOR INSTRUCTION MANUAL 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

More information

Procedure for the Approval of New Fire Detection and Alarm Technologies

Procedure for the Approval of New Fire Detection and Alarm Technologies VdS Guidelines for Automatic Fire Detection and Fire Alarm Systems VdS 3469en Procedure for the Approval of New Fire Detection and Alarm Technologies VdS 3469en : 2016-01 (01) Publisher and publishing

More information

Economically Productive Universal applicable

Economically Productive Universal applicable Professional installation- and electrical connection technique druseidt battery operated tool program: Electro-hydraulic operated crimping- and cutting tools for industrial as well as applications in craft

More information

VIBRA-series: VIBRA, VIBRA +

VIBRA-series: VIBRA, VIBRA + DATASHEET VIBRA-series (VIB.00100/..120/..130) VIBRA-series: VIBRA, VIBRA + Profound VIBRA-series Vibrations from pile driving, construction, road or rail traffic, demolition work and blasting can create

More information

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No & 6339H_Manuals 10/24/12 12:56 PM Page 1 Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No. 40-6685 & 40-6687 Instruction Manual Congratulations on your choice of this Self-Leveling

More information

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

LED Colour Flood 10W / 30W RGB LED floodlight. user manual LED Colour Flood 10W / 30W RGB LED floodlight user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet:

More information

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities. i-con Switchgear Condition HV Switchgear Integrated Substation Condition ISCM Answers for Infrastructure & Cities. The challenge: Reliable energy supply is the key to success for every enterprise in a

More information

ELECTRICAL SAFETY for GAS ENGINEERS ACV. Do a GOOD JOB Take care of YOURSELF STAND OUT from the competition 2018 ISSUE 1. sterling4gas.co.

ELECTRICAL SAFETY for GAS ENGINEERS ACV. Do a GOOD JOB Take care of YOURSELF STAND OUT from the competition 2018 ISSUE 1. sterling4gas.co. ELECTRICAL SAFETY for GAS ENGINEERS 238.7 ACV Do a GOOD JOB Take care of YOURSELF STAND OUT from the competition 2018 ISSUE 1 sterling4gas.co.uk 01536 400802 QUESTIONS GAS ENGINEERS SHOULD ASK... 1. How

More information

VAMP 120 & 121. Arc flash detection units. Product picture

VAMP 120 & 121. Arc flash detection units. Product picture Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize

More information

Heating Mats and Jackets. innovations in heat tracing

Heating Mats and Jackets. innovations in heat tracing Heating Mats and Jackets innovations in heat tracing The eltherm GmbH Solutions with electrical heat tracing systems eltherm GmbH is an international operating company specialising in the field of electrical

More information

EKL3 short circuit and earth fault indicator

EKL3 short circuit and earth fault indicator EKL3 short circuit and earth fault indicator Summary EKL3 short circuit grounding fault indicators are mainly used in various Ring Main Units(RMU), high-voltage switchgears and cable branch units to ascertain

More information

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g. INSTRUCTION MANUAL FA 400 Humidity measuring instruments with display and alarm for measurement of the pressure dew point and the atmospheric dew point in different applications: - compressed air plants

More information

SHORT WAVE INFRARED PANEL DRYER

SHORT WAVE INFRARED PANEL DRYER INSTRUCTIONS FOR: SHORT WAVE INFRARED PANEL DRYER MODEL: IR3000 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

More information

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , & 1622i_Manuals 12/14/16 12:52 PM Page 1 Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No. 40-6685, 40-6687 & 40-6688 Instruction Manual Congratulations on your choice of this

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

Monitoring Devices 11/1

Monitoring Devices 11/1 11/4 Introduction 11/6 5TE5 8 light indicators 11/7 4AC3 0, 4AC3 1 bells, buzzers 11/7 5TT3 46 fault signaling units 11/8 7LQ2 1, 5TT3 3 dusk switches 11/9 7LQ2 0 temperature controllers 11/9 5TT3 170

More information

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH4 C3H8 H2 Gas leak testing Over and over again, devastating explosions and fires are caused

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management Reyrolle Protection Devices 7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management 7XG3120 - Arc Fault Monitor Relay The over-current caused by an arc is, due to its resistance, lower than the over-current

More information

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing Ready-to-Use Heat Tracing Solutions for Laboratory Applications innovations in heat tracing eltherm GmbH Solutions with Electric Heat Tracing Systems eltherm GmbH is an internationally operating engineering

More information

DALI EMERGENCY LIGHTING ...MADE EASY DALI EMERGENCY LIGHTING TAP SCREEN TO CONTINUE N-LIGHT - REF: 7294V3 04/12 POWERED BY: DALI EMERGENCY LIGHTING

DALI EMERGENCY LIGHTING ...MADE EASY DALI EMERGENCY LIGHTING TAP SCREEN TO CONTINUE N-LIGHT - REF: 7294V3 04/12 POWERED BY: DALI EMERGENCY LIGHTING N-LIGHT - REF: 7294V3 04/12 DALI EMERGENCY LIGHTING TAP SCREEN TO CONTINUE TAP SCREEN TO CONTINUE DALI EMERGENCY LIGHTING POWERED BY: DALI EMERGENCY LIGHTING...MADE EASY PAGE 2 www.mackwell.com Introducing

More information

Safety Laboratory Gas Burner. - A step ahead! Technical Data: The range of delivery:

Safety Laboratory Gas Burner. - A step ahead! Technical Data: The range of delivery: - A step ahead! The innovative SCS - Series provides maximum safety and highest convenience for all flame-related applications in the laboratory. Quality down to the smallest detail The unique quality

More information

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02 7 783 ISO 9001 DETACTOGYR Flame Safeguard Series 02 The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil

More information

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor 4 Zones, 8 Sensors Features Four independent arc fault tripping zones 1 or 2 arc fault sensors per zone allowing up to 8 arc fault sensors per module Trip indication

More information

One giant leap for safety: AZM400.

One giant leap for safety: AZM400. One giant leap for safety: AZM400. Holding force: Unlocking against lateral force: Mechanical life: Protection class: Dimensions: Supply voltage: Electrical connection: AZM400 10,000 N 300 N > 1,000,000

More information

Conductivity Electrode LRG Original Installation Instructions English

Conductivity Electrode LRG Original Installation Instructions English Conductivity Electrode LRG 16-4 EN English Original Installation Instructions 818854-02 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...5 Directives and standards

More information

NEW GENERATION COMPACT HAND HELD METAL DETECTION SET

NEW GENERATION COMPACT HAND HELD METAL DETECTION SET PD140N NEW GENERATION COMPACT HAND HELD METAL DETECTION SET NIJ-0602.02 Compliant FEATURES NIJ Standard - 0602.02 Compliant Compact, Elegant, Robust and Ergonomic Uniform Detection of Magnetic and Non-Magnetic

More information

A Soft (R)evolution. For a flexible future: modular fire alarm technology by ESSER

A Soft (R)evolution. For a flexible future: modular fire alarm technology by ESSER A Soft (R)evolution For a flexible future: modular fire alarm technology by ESSER A new outlook for the future: F uture-oriented fire alarm systems need to fulfill a complex range of requirements, including

More information

tools 8000 The perfect all-round tool: tools 8000 Programming and service software for alarm systems Fire detection technology

tools 8000 The perfect all-round tool: tools 8000 Programming and service software for alarm systems Fire detection technology tools 8000 The perfect all-round tool: tools 8000 Programming and service software for alarm systems Fire detection technology 02 03 The circle is complete: programming from installation to maintenance

More information

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET NSN: 6665150114797 WIDE SEARCH AREA HAND-HELD METAL DETECTION SET Wide Search Area for Faster and Accurate Screening Operations Search operations allowed even in close proximity of metal reinforced floors

More information

Alarm System SECURE AS 302

Alarm System SECURE AS 302 Alarm System SECURE AS 302 Operating Manual SECURE Light app now available! Table of Contents Before You Start.................................. 4 User Information....................................4

More information

Reliable solutions for electrified railway systems

Reliable solutions for electrified railway systems Reliable solutions for electrified railway systems 1 2 3 Insulation Enhancement System Insulation Enhancement System 1. Raychem MVLC: (Medium Voltage Line Cover) Provides insulation for catenary, droppers

More information

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR INSTRUCTION MANUAL Index 1. Safety rules... 2. General description... 3. Principle of how it works... 4. Check it and get it going... a. Check

More information

Level Electrode NRG NRG Original Installation Instructions English

Level Electrode NRG NRG Original Installation Instructions English Level Electrode NRG 10-52 NRG 16-52 EN English Original Installation Instructions 819123-02 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and

More information

Howler Go-Link Evacuation Alarm

Howler Go-Link Evacuation Alarm Howler Go-Link Evacuation Alarm Go simple, GoLink In an age of sophistication, complexity and novelty, we sometimes lose sight of what we actually need, and ultimately what we actually want. When it comes

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality FlexLine Steam humidifier New flexibility in award-winning quality A series of units with a wide performance range for every area of application Individual confi guration Easy operation Highest quality

More information

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207 EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please

More information

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex. Data sheet testo 317-2 / testo 316-1 / testo 316-2 / testo gas detector / testo 316-EX Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH 4 C

More information

E-pro. Time adaptor with E-Pro Stick for thermostatic valves

E-pro. Time adaptor with E-Pro Stick for thermostatic valves E-pro Time adaptor with E-Pro Stick for thermostatic valves pressurisation & Water Quality Balancing & control thermostatic control ENGINEErING ADVANTAGE E-Pro Description HEIMEIER E-Pro time adaptor for

More information

DS500. Alarm Sensors (built in) Power. Sounds. Accessories* Attachment

DS500. Alarm Sensors (built in) Power. Sounds. Accessories* Attachment DS500 DEWALT MOBILELOCK GPS LOCATOR WITH ANTI-THEFT ALARM is an innovative, wireless system designed to monitor valuable mobile assets wherever are located. MOBILELOCK offers tracking, notification and

More information

PD140N NEW GENERATION COMPACT HAND HELD METAL DETECTION SET. Threat Detection through Electromagnetics. NIJ Compliant.

PD140N NEW GENERATION COMPACT HAND HELD METAL DETECTION SET. Threat Detection through Electromagnetics. NIJ Compliant. PD140N NEW GENERATION COMPACT HAND HELD METAL DETECTION SET NIJ-0602.02 Compliant Certified according to EU Regulation on Civil Aviation Security FEATURES NIJ Standard - 0602.02 Compliant Compact, Elegant,

More information

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR 7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or

More information

EST User Manual. (Please read this manual carefully before using)

EST User Manual. (Please read this manual carefully before using) EST-1000 Handheld Intelligent Toxic Gas Detector User Manual (Please read this manual carefully before using) ENVIRONMENTAL SENSOR TECHNOLOGY CO.INC. Contents I. Product Overview...1 II. Product Description...1

More information

Parker icount Oil Sampler (IOS)

Parker icount Oil Sampler (IOS) Parker icount Oil Sampler (IOS) Portable condition monitoring for hydraulic oil and fuel systems Accurate condition monitoring made quick, simple and cost effective The icountos (IOS) is an innovative

More information

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies Version:- 2.0 Date of Issue:- May 2015 Page 1 of 17 NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies 1. Purpose The purpose of this

More information

Temperature Sensor TRG Original Installation Instructions English

Temperature Sensor TRG Original Installation Instructions English Temperature Sensor TRG 5-6.. EN English Original Installation Instructions 818597-05 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards

More information

We measure it. testo 316-Ex CH 4 testo 316-1

We measure it. testo 316-Ex CH 4 testo 316-1 Gas leak detectors testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH 4 C 3 H 2 Gas leak testing Over and over again, devastating explosions and fires are caused by leaky gas pipelines.

More information

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Sinteso Cerberus PRO FDA241, FDA221 ASD Aspirating smoke detector Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Patented technology Early

More information

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems 41 Accurate Condition Monitoring made Quick, Simple and Cost Effective The (IOS) is an innovative solution to the

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60364-1 Fifth edition 2005-11 Low-voltage electrical installations Part 1: Fundamental principles, assessment of general characteristics, definitions This English-language version

More information

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series DESCRIPTION The SZL-VL-S Series miniature-type limit switch is designed for use in applications where limited space is available. With IP67

More information

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions

More information

Level Electrode NRG Original Installation Instructions English

Level Electrode NRG Original Installation Instructions English Level Electrode NRG 16-36 EN English Original Installation Instructions 819257-01 Contents Contents Page Important notes Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards

More information

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1 CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V PART NO: 6920330 & 6920332 OPERATING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1218 - ISS 1 INTRODUCTION Thank you for purchasing this CLARKE Ceramic

More information

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES NIJ-0602.02 Standard Compliant Wide Search Area for Faster and Accurate Screening Operations Elegant, Robust and Ergonomic High

More information

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation The most user friendly Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Security Alarm System L S 4 0 0 Section 2 Planning your Installation 2.1 Location of

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control

More information

Alarm Switchgear AS1-M

Alarm Switchgear AS1-M Installation, Operating and Maintenance Instructions 1/7 Installation, Operating, and Maintenance Manual for Alarm Switchgear AS1-M These installation, operating and maintenance manual must be handed to

More information

DEKO 260 Washer - Disinfector - Dryer

DEKO 260 Washer - Disinfector - Dryer DEKO 260 Washer - Disinfector - Dryer HIGH QUALITY, EFFICIENT WASHING PERFORMANCE WITH SHORT CYCLE TIMES DEKO 260 The Deko 260 washerdisinfector-dryer is designed and manufactured to be fully compliant

More information

Spy model 673 wet sponge holiday detector ope rati ng instructions

Spy model 673 wet sponge holiday detector ope rati ng instructions Spy model 673 wet sponge holiday detector ope rati ng instructions picltd.com PIPELINE INSPECTION COMPANY welcome Thank you for purchasing the SPY Model 673 Wet Sponge Holiday Detector. Pipeline Inspection

More information

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions Magnetic-Inductive Flow Velocity Sensor PIT Installation and Operating Instructions Table of contents 1 IDENTIFICATION... 3 1.1 Manufacturer/supplier... 3 1.2 Product type... 3 1.3 Product name... 3 1.4

More information

Tools for Cu-terminals mm², Al-terminals mm² (-35 solid) mm² and C-sleeves 6-50 mm²

Tools for Cu-terminals mm², Al-terminals mm² (-35 solid) mm² and C-sleeves 6-50 mm² Tools for Cu-terminals 10-240, Al-terminals 16-25 (-35 solid) and C-sleeves 6-50 T2600/T2600B/T2600C T2600/T2600B/T2600C Mechanical handtool for crimping of Cu- and Al-terminals: T2600 for KRF/KSF, T2600B

More information

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX 1 EUROSTER 2510TX Introduction Congratulations on the purchase of your new Digital Thermostat. Thanks to the latest microprocessor technology, the thermostat offers many convenient and energy-saving features.

More information

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Type Test chamber capacity SC 2000 MHG approx. 3400 l Radiation area approx. 1.36 m 2 TECHNICAL DATA Characteristic values for

More information

Tempest TP420/180 Electric Pressure Washer

Tempest TP420/180 Electric Pressure Washer Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Modular Fire Panel 5000 Series Just as flexible as your plans

Modular Fire Panel 5000 Series Just as flexible as your plans Modular Fire Panel 5000 Series Just as flexible as your plans 2 One modular system does it all Unbeatable flexibility With the Modular Fire Panel 5000 Series, Bosch is again redefining the market: With

More information

Radio fire warning panel SRC 3000

Radio fire warning panel SRC 3000 Radio fire warning panel SRC 3000 6 zone radio fire warning panel Operating instructions Version 1.2 Art. 32487 detectomat GmbH Headquarter: Phone: +49 (0) 4102-2114-60 An der Strusbek 5 Fax: +49 (0) 4102-2114-670

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage Product Bulletin VeriSafe Absence of Voltage The Safe Way to Verify the Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification

More information

polar zone components and systems for extreme temperatures

polar zone components and systems for extreme temperatures polar zone components and systems for extreme temperatures 2 Our customers safety in their day-to-day work is the main focus of our business. The company has been working towards this for over 80 years

More information

Electronic timeswitch

Electronic timeswitch Electronic timeswitch RWB1007 To control combination boilers and single zone applications together with the appropriate thermostat. Easy-to-read backlit display Time programming 7-day 2/3 ON/OFFs Advance

More information

Operating Instructions

Operating Instructions Operating Instructions TEKA Cartmaster Type PF-W 1, PF-W 2 TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0)

More information

Weigh In Motion (WIM) Wheel Impact Load Detector (WILD)

Weigh In Motion (WIM) Wheel Impact Load Detector (WILD) Weigh In Motion (WIM) Wheel Impact Load Detector (WILD) The WIM & WILD is a smart solution entirely based on optical fibre sensors technology, that combines the Weigh In Motion (WIM) functionality with

More information

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage. Product Bulletin VeriSafe Absence of Voltage The Safe Way to Verify the Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification

More information

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex. Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH 4 C 3 H 2 Gas leak testing Over and over again, devastating explosions and fires are caused

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

Battery Interconnects

Battery Interconnects Battery Interconnects Product Facts Total interface solution Current capacity 7 Amps/ single contact at 30 C T-Rise Choice of right-angle or vertical mount headers with left, right or keyless polarization

More information

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Knürr RMS Compact II. Knürr RMS Compact II 2.81 Knürr RMS Compact II Knürr RMS Compact II 2.82 to 2.85 2.81 Knürr RMS Compact II Damage prevention with checks and controls System and network management requirements mean the systems ambient conditions

More information

Safety requirements for voltage testing instruments

Safety requirements for voltage testing instruments MODEL POLICY Safety requirements for voltage testing instruments 1. FOREWORD 1.1. Approval 1.1.1. This standard is owned by. name of promulgating organization or department 1.1.2. Questions related to

More information

Internet. Climate rating definitions. Customer service.

Internet. Climate rating definitions. Customer service. Climate rating definitions Climate rating SN = Ambient temperatures of +10 C to + 32 C Climate rating N = Ambient temperatures of +16 C to + 32 C Climate rating ST = Ambient temperatures of +16 C to +

More information

Electronic Temperature Controller 70304,

Electronic Temperature Controller 70304, Electronic Temperature Controller 70304, 70304.2 Instruction Manual Version 1.00.01 List of content 1 General information... 4 2 Declaration of conformity... 4 3 Safety instructions... 5 4 Warranty...

More information

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual Model: RT310i Smartphone Controlled Thermostat Installation Manual Contents Product Compliance... 3 Safety Information... 3 Introduction... 4 Overview... 5 Box contents... 5 Features... 5 Connecting the

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Integrated electronic maximum-minimum thermometer, with factory programmed alarms, for vaccine refrigerators

More information

FIA FORMULA E CHAMPIONSHIP TEAM esafety and checklists. Season

FIA FORMULA E CHAMPIONSHIP TEAM esafety and checklists. Season FIA FORMULA E CHAMPIONSHIP TEAM esafety and checklists Season 2016-2017 CONTENTS MANDATORY TEAM EQUIPMENT FORMULA E CAR & ELECTRICAL HAZARD SAFETY DATA SHEET PRESENTATION ELECTRICAL RISK AND SAFETY DEVICES

More information

SEPTIC FLUID ASPIRATOR MEDAP-VENTA SP 26 N MEDAP-VENTA SP 26 A

SEPTIC FLUID ASPIRATOR MEDAP-VENTA SP 26 N MEDAP-VENTA SP 26 A SEPTIC FLUID ASPIRATOR MEDAP-VENTA SP 26 N MEDAP-VENTA SP 26 A This document is intended to provide information to an international audience outside of the US. VENTA SP 26 3 TOP QUALITY TECHNOLOGY FOR

More information

Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q

Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q Documentation Glass -/quartz insulated Heating Cable Factory terminated Type: ELK-H, -HS, -Q ELW-H, -HS, -Q 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of

More information

HD 7/11-4 Cage Classic

HD 7/11-4 Cage Classic HD 7/11-4 Cage Classic Long service intervals and high-quality components such as the crankshaft pump with ceramic piston are among the many strengths of the HD 7/11-4 Cage Classic single-phase high-pressure

More information

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET PD20 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET NIJ-0602.02 Compliant Certified according to EU Regulation on Civil Aviation Security NSN: 666515011797 FEATURES NIJ-0602.02 Standard

More information

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear IEC/PAS 62271-109 Edition 1.0 2002-07 High-voltage switchgear and controlgear Part 109: Alternating-current series capacitor by-pass switches PUBLICLY AVAILABLE SPECIFICATION INTERNATIONAL ELECTROTECHNICAL

More information

GMH 285 / GMH 285-BNC

GMH 285 / GMH 285-BNC GMH 285 GMH 285-BNC H69.0.01.6C-02 Operating Manual Pt1000 Precision Thermometer For exchangeable probes, with alarm as of version V1.0 GMH 285 / GMH 285-BNC GMH-GREISINGER GMH-GREISINGER WEEE-Reg.-Nr.

More information

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10 Qualification: Date Completed: 02 Feb 17 Unit: FIA AO Level 3 Fire Detection and Alarm Advanced Installer Development Group: FD&A Development Group Guided Learning Hours (GLH) 8 Invigilated Assessment

More information

EUROPUMP ATEX Guideline Part II

EUROPUMP ATEX Guideline Part II EUROPEAN ASSOCIATION OF PUMP MANUFACTURERS ASSOCIATION EUROPÉENNE DES CONSTRUCTEURS DE POMPES EUROPÄISCHE VEREINIGUNG DER PUMPENHERSTELLER EUROPUMP ATEX Guideline Part II Application of the EC-Guidelines

More information

NRG NRG NRG NRG

NRG NRG NRG NRG GESTRA Steam Systems NRG 16-50 NRG 17-50 NRG 19-50 NRG 111-50 EN English Installation Instructions 818954-04 Level Electrodes NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50 1 Contents Important Notes Page

More information

KM300 Carbon Monoxide Detection System Installation Manual

KM300 Carbon Monoxide Detection System Installation Manual GE Security KM300 Carbon Monoxide Detection System Installation Manual P/N 1068922 REV 2.0 16SEP09 Copyright Copyright 2009 GE Security, Inc. All rights reserved. This document may not be copied in whole

More information

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user. Climapro 2 User manual To be left with the user wireless room thermostat without receiver www.glow-worm.co.uk table of contents READ CAREFULLY BEFORE USING 1 Introducing your Climapro 2... 3 1.1 Description...

More information