luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

Size: px
Start display at page:

Download "luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor"

Transcription

1 luxcontrol lighting control sstem ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 1 DSI or LI devices (max. 5 per output channel) LI/DSI output channels with adjustable negative offset from channel to channel 1 Ambient light sensor with motion detector Max. installation height 5 m Switch input for on/off switching and dimming Can be remote controlled Individual adjustment of the parameters with ILD Programmer or DSI-SMART Programmer 5-ear guarantee ILD 5DPI 14F È Wiring diagrams and installation examples, page 7 ILD 5DPI 14F Black ILD 5DPI 14F Black 1.8m 1

2 luxcontrol lighting control sstem ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor Technical data Rated suppl voltage 4 V Mains frequenc 5 / 6 Hz Power W Stand-b power.5 W Momentar-action switch input for dimming single Digital control line DSI/LI Control output (devices) 1 Max. output cable length at 1.5 mm² 1 m Operating temperature C Storage temperature C Tpe of protection IP Max. casing temperature tc 75 C ,4 44,4 1,8 Ø13,9 1,9 3 Ordering data Tpe Article number Mounting Packaging carton ILD 5DPI 14f 813 Luminaire installation 1 pc(s). ILD 5DPI 14f Black 8159 Luminaire installation 1 pc(s). ILD 5DPI 14f Black 1.8m 8158 Luminaire installation 1 pc(s). Illuminance (factor default) Motion detection angle smmetric Specific technical data Tpe Detection Light detection angle Light measurement at Max. cable length sensor asmmetric the sensor head 1 ILD 5DPI 14f lx 15 lx 78.8 m ILD 5DPI 14f Black lx 15 lx 78.8 m ILD 5DPI 14f Black 1.8m lx 15 lx m 1 The measured value at the sensor head corresponds to approx. 15 to, lux on the surface measured. The illuminance is set for a room defined b Tridonic. Depending on the actual room (reflectance) the measured illuminance ma deviate from this value. The illuminance should therefore be checked in the installation and adjusted if necessar.

3 luxcontrol lighting control sstem ACCES- SORIES REMOTECONTROL IR6 Product description Optional infra-red remote control Switching on and off (On/Off button) Dimming (Up/Down button) Activation of automatic lighting control Setting the threshold control point (Set button) Ordering data Tpe Article number Dimensions L x W x H Packaging carton REMOTECONTROL IR x 4.5 x 7. mm 5 pc(s). ACCES- SORIES ILD Programmer Product description Optional infra-red programming unit for ILD Setting of predefined discrete parameter values Programmable functions such as light level, time dela, P.I.R., bright-out, power up Ordering data Tpe Article number Packaging carton Weight per pc. ILD Programmer pc(s)..3 kg 3

4 luxcontrol lighting control sstem ACCES- SORIES DSI SMART Programmer Product description Optional infra-red programming unit for DSI-SMART PTM or ILD 1 44,5 1 Settings can be read and modified Programmable functions such as light level, time dela, P.I.R., bright-out, power up 18 Ordering data Tpe Article number Packaging carton Weight per pc. DSI-SMART Programmer pc(s)..35 kg 1 At version.3 for ILD. ACCES- SORIES 5DPI 14f Mounting Kit Product description Mounting frame for attaching all 5DP 14f sensor directl to the luminaire housing Shutter for preventing movement detection in one direction Ordering data Tpe Article number Packaging carton Weight per pc. 5DPI 14f mounting kit pc(s)..4 kg 5DPI 14f mounting kit black pc(s)..4 kg 4

5 luxcontrol lighting control sstem ILD The basic DIM ILD provides the basis for an eas-to-use and cost-effective lighting sstem with motion detection. When the sensor detects movement it triggers a individual adjustable motion detection profile in the control unit. As the amount of natural ambient light changes the illuminance from the artificial lighting sstem is adjusted. The connected luminaires can be switched on and off via momentar-action switch or remote control possible. IR is alwas active. Standards EN 5515 EN EN EN EN EN Glow-wire test according to EN passed. LI standard The ILD is designed to control control gear with LI standard IEC 699 (LI V) and IEC 6386 (LI V1). Installation Don t use the ILD without the sensor. DSI/LI is not SELV. The installation instructions for mains voltage therefore appl. The maximum cable length between the external switch and ILD is 1 m. The cable between the luminaire installation sensor and the base module must not be extended. A snchronous operation of LI and DSI ballasts at the same control gear is not possible. The maximum cable length of the DSI / LI control signal (for a cable cross-section of 1,5 m ) must not be exceeded. An number of push to make switches ma be connected in parallel to the inputs. Do not connect standard switches to the input. Please ensure that the detection range of the sensor lies in the lighting area of the controlled luminaires. Please ensure that the detection ranges of the sensors do not overlap. This ma have influence to the lighting control. Heaters, fans, printers and copiers located in the detection zone ma cause incorrect presence detection. To avoid false readings, the sensor should be installed so there is no direct light from the lamp in the detection zone. To avoid false measurements caused b the light from other luminaires we recommend that the sensor should be located centrall in the luminaire. Sensor wires must be routed separatel from the lamp wires and mains cables otherwise the lighting control sstem ma malfunction. If separate routing is not possible (for reasons of space) shielded lamp wires and mains cables must be used. Mounting variants luminair housing: Size of the sheet: mm Size of the sheet:.6.8 mm 1,5,5 19,1 ø14,1 +,, +, 4 +, +,1 -,1 ø1,8 +,1 3, -,15 Size of the sheet:.8 3. mm 3,3 5,5 41,1 +, 14,1 +, R1,9 -, 5

6 luxcontrol lighting control sstem Mounting in luminaire housing with Mounting Kit: Size of the sheet:.8. mm Dimension drawing for needed mounting opening, ø1, +,1 R,9 1,8±,5 Shutter support ring has to be snapped into the shutter support Thickness metal sheet.8. mm.8 1,65±,5 Option shutter: has to be snapped into the shutter support ring Mounting Kit mounting Mounting Kit Shutter Area which is masked b the shutter

7 luxcontrol lighting control sstem Switch ILD has an input terminal for an external switch. An number of switches can be connected in parallel to the terminal. Short press (> 5 6 ms): Long press (> 6 ms): ON/OFF Dim up/down A change in the light value deactivates lighting regulation onl temporaril. As soon as the luminaire has been automaticall switched on again (motion detection) or manuall switched off and on again, regulation is activated again. x short press: The overwritten setpoint light value is stored (luminaire acknowledges b flashing twice) Function is lockable via the DSI programmer DSI/LI interface The interface selection DSI or LI is made b the DSI SMART Programmer. Wiring diagram ILD L N Cable tpes and cable cross-sections Solid wire with a cable cross-section of.5 mm² to 1.5 mm². wire preparation: mm² PCA 8 9 mm L N T ILD CH1 D1 D 3 4 PCA Sensor CH D1 D 6 7 ILD Sensor Enhancement of controllable light point B using a combination of LI Repeater and LI Power Suppl it is possible to enhance the sum of controllable light points. The schematic visualizes the wiring. L N Max. Max LCA N ~ L PS LCA L N T ILD CH1 D1 D Sensor CH D1 D IN LI Repeater OUT ILD Sensor Use onl in combination with LI Repeater ( ) and one of the following LI Power Supplies: LI PS1 (43433), ma, max. 1 additional devices LI PS (8876), 4 ma, max. 1 additional devices Wire length for 1.5 mm cables: from to LI Repeater max. 1 m after LI Repeater max. 3 m This combination can be used on CH1 and CH. 7

8 luxcontrol lighting control sstem Light level recognition area Sensor alignment h α = α = 38 α = 3 38 h h * d 1.7 m 1.3 m.7 m 1. m.8 m. m 1.6 m.8 m 1. m 3. m.3 m 1.8 m.9 m 1.3 m 3.7 m.5 m. m 1. m 1.4 m 4. m.7 m.1 m 1.1 m 1.6 m 4.4 m 3. m.3 m 1. m 1.7 m 4.9 m 3.5 m.7 m 1.4 m. m 5.7 m 4. m 3.1 m 1.6 m.3 m 6.5 m * The recommended maximum room height for office applications is 3 m and for corridor applications for example 4 m. Up to m mounting height presence is detected and over m motion is detected. Calculation of the diameter (light area): = tan(a) h = tan(a) h = tan(a) h Calculation of the diameter (motion area): d = tan(,5 a) h Example for light and motion detection area at height of 1.7 m: 1 m.7 m 1.3 m Light level recognation area 1 m Presence / motion detection.8 m Presence / motion detection h α = 78 d 8

9 luxcontrol lighting control sstem The following operating modes can be set for the motion detector via the ILD Programmer or DSI-Smart Programmer: Active Off Onl Never Off Inactive The light is switched on or off automaticall depending on whether or not there is a person in the room. The motion detector onl switches the connected lighting off. The luminaires are switched on manuall via the connected external switch or infra-red control. If it has not detected an movement the sensor dims to the second light value parameter and remains at this value The motion sensor is deactivated. The light must be switched on or off manuall. Switch-off dela This is the time after which the lighting is switched off if no movement is detected. It can be set via the time dela parameter. Second light value On the ILD ou can set whether the light is to be switched off after the switch-off dela or dimmed to the second light value. The light value and the dwell time (how long the value is held) can be set via the when vacant and sec. level parameters. Offset The light level of channel is less then the light level of channel 1. The difference can be set with the parameter Offset Value via ILD Programmer or DSI-SMART Programmer. Channel Channel 1 4 % 7 % 5 LUX Artificial light Natural light Manual-off dela If the sstem is switched off manuall via the switch or remote control the motion sensor is deactivated. At the end of a 1 minutes dela if motion has not been detected the motion sensor is activated again. If the sensor detects motion during the Manual Off dela, the time will be reset to the start. The following operating modes can be set for lighting control via the DSI-Smart Programmer: Active Inactive Constant light control is active. Constant light control is deactivated. The lighting is switched on at 1%. The value is set with the light-level parameter. If the value is set to max then lighting control is deactivated. For all other values lighting control is active. Setpoint adjustment DSI-SMART Controller: Pressing the Set button stores the current light value as a new setpoint. ILD Programmer or DSI-SMART Programmer: Via the light-level parameter External switch: Briefl pressing the switch twice stores the current light value as a new setpoint. (Function is lockable via the ILD Programmer or DSI Programmer) Bright-out If the nominal illuminance (e.g. 5 lux) is exceeded for 1 minutes b more than 15 % (e.g. 75 lux), the lighting is switched off even if motion is detected. The lighting is switched on again when the measured light value falls below the setpoint. The bright-out function is displaed b a green status indication LED at the sensor. This function can be deactivated via the ILD Programmer or DSI-SMART Programmer. 9

10 luxcontrol lighting control sstem User-definable parameters ILD have the following user-definable parameters (since DSI-SMART Programmer version.3): The values in parentheses are the factor default settings. The adjustable values for the ILD Programmer is available in a separatel documentation on Parameter light-level time dela if vacant Range (Factor setting) 1 1/max (7) 3 s 6 min/con ( min) off 3 s 6 min/con (off) sec. level 1 1 % (1 %) P.I.R active/inactive/off onl (active) bright-out Power up hold overwrite PTM Set LIorDSI Offset Mode es/no (es) on/off (on) on/off (off) on/off (on) DSI/LI (DSI) fixed/converging (converging) Offset Value to -7 % (-3 %) Description Selectable lighting control set point, 1 1 increments. max also makes it possible to set the control gear to full power. (DSI 55) man indicates whether the adjustment value was overwritten b the SET function of the SMART Controller. Dela time after the last detected movement The following values can be set: 3 seconds, 1,, 3, 5, 1, 15,, 3, 45 and 6 minutes and continuous (no switch-off) The off setting switches the luminaire off after the dela time has elapsed. If a time value is set, the luminaire dims to the sec. level parameter and onl switches off after the previousl set time has elapsed. The following values can be set: off, 3 seconds, 1,, 3, 5, 1, 15,, 3, 45 and 6 minutes and continuous ( never OFF function) Second light level to which luminaire dims after the dela time has elapsed. (in conjunction with the if vacant parameter) With the active setting, the lighting is automaticall switched on or off depending whether a person is present. With the inactive setting, the ILD/DSI-SMART (PTM) can, in combination with continuous time dela, onl be used for lighting control. With the off onl setting, the lighting has to be switched on manuall (momentar-action switch, remote control) but is switched off b the presence detector. With the es setting, the lighting switches off as soon as the light level exceeds 15 % of the set point for longer than 1 minutes, for instance, if the room is adequatel illuminated b sunlight. If the actual value falls below 1 % of the set point, the lighting switches back on again. With the no setting, the lighting remains switched on (at the minimum dimming level) even if the room is adequatel illuminated b sunlight and no artificial lighting is required. With the on setting, the luminaire switches on after a mains break. With the off setting, the luminaire does not switch on after a mains break. The presence detector becomes active again after 15 seconds. If the light level is manuall dimmed via a momentar-action switch or remote control, lighting control stops. The previousl set dimming level retains its fixed value as long as lighting control is not activated b manual intervention (momentar-action switch or remote control). If there is no movement in the room in this state and the time dela has elapsed, the control unit stores the fixed dimming level. With the off setting, lighting control is restarted each time movement is detected. With the on setting, the control unit switches the luminaires back to the fixed dimming level each time movement is detected and lighting control remains stopped. With this setting, lighting control can be activated again via the remote control (Automatic button). If lighting control was active before repeated detection or if the lighting was switched off manuall, the luminaires and lighting control are switched on after movement is detected in order to prevent people having to enter a dark room. With the on setting, it is possible to save the currentl set light level as a lighting control set point b pressing the momentar-action switch twice shortl. With the off setting, this function is disabled. With the DSI setting, DSI interface mode is enabled. With the LI setting, LI interface mode in which LI broadcast commands are sent is enabled. This parameter specifies how the adjustable Offset Value of the ILD behaves from channel to channel 1 over the dimming range. With the fixed setting, the previousl set Offset Value remains the same across the dimming range. (e.g. with an Offset Value of -3 %, channel remains at 7 % when channel 1 has reached 1 %). With the converging setting, the previousl set Offset Value remains the same up to a specific dimming level and decreases the closer one gets to 1%. (e.g., with an Offset Value of -3 %, the dimming level of channel is 4 % and that of channel 1 is 7 %. but both channels simultaneousl change to a dimming level of 1 % if the lighting is dimmed up). Adjustable brightness difference between channel and channel 1 of the ILD. The following values can be set: %, -1 %, - %, -3 %, -4 %, -5 %, -6 % and -7 % 1

11 luxcontrol lighting control sstem Default Parameter Motion Detector Parameter A light-level 1 time dela B sec. level if vacant 11

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor luxcontrol lighting control sstem ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI

More information

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1 Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) DALI/DSI output channels with adjustable negative offset from channel to channel 1 Ambient light

More information

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel)

More information

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor ILD Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) 2 DALI/DSI output channels

More information

11,1 30. Ordering data

11,1 30. Ordering data ID Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or I ballasts I/DSI output channels with adjustable negative offset

More information

DALI MSensor 02 Multi-sensor for DALI system

DALI MSensor 02 Multi-sensor for DALI system MSensor 02 Multi-sensor for system Product description Component of the comfortdim system ( standalone) With ambient light dependent control and motion detection Simple group assignment via rotary switch

More information

DALI MSensor 02 Multi-sensor for DALI system

DALI MSensor 02 Multi-sensor for DALI system MSensor 02 Multi-sensor for system Component of the comfortdim system ( standalone) With ambient light dependent control and motion detection Simple group assignment via rotary switch Multiple MSensors

More information

luxcontrol DALI basicdim DGC Product Manual

luxcontrol DALI basicdim DGC Product Manual luxcontrol DALI basicdim DGC Product Manual Table of Contents 1. Scope of documentation 3 1.1. Copyright.................................................................................................................

More information

Installation Instruction

Installation Instruction INFRARED PROGRAMMING UNIT FOR AMBIANT LIGHT & MOTION SENSOR 300 90 019 Delta Light nv Muizel straat 2 B-8560 Wevelgem (Moorsele) Belgium T +32 (0)56 435 735 F +32 (0)56 435 736 Info@deltalight.com www.deltalight.com

More information

LPCMPIRM65 & LPCMPIRDSI65

LPCMPIRM65 & LPCMPIRDSI65 Product Guide LPCMPIRM65 & LPCMPIRDSI65 Luminaire high mount PIR detectors Overview The LPCMPIR PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

LPC3BSP65 & LPC3BDP65

LPC3BSP65 & LPC3BDP65 Product Guide LPC3BSP65 & LPC3BDP65 Batten mount PIR detectors Overview The LPC3B series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR In the Master function, the remote control entries will be acknowledged as follows: acknowledged 3 x with the red LED In the Slave function, each detection is acknowledged 2 x with the green LED. NOTE:

More information

Detector switch - Dual Tech

Detector switch - Dual Tech Page 1. Use.................................... 1 2. Technical characteristics................1 3. Dimensions............................ 2 4. Connection........................... 2 5. Installation...........................

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

SMART BASIC BASIC-IR DAYLIGHT

SMART BASIC BASIC-IR DAYLIGHT LUXMATE Lighting Control System LUXMATE. The ing system for maximum quality and dimming convenience. SMART BASIC BASIC-IR DAYLIGHT The art of modern technology lies in making complicated things simple.

More information

Integrated PIR detectors

Integrated PIR detectors EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Premium Version Tri-level Dimming Control

Premium Version Tri-level Dimming Control 0 Premium Version Tri-level Dimming Control Model: HC9VRC with HRC-0 Infrared remote receiver Detection area Buzzer Sensor antenna indication Daylight threshold Stand-by period. 86. 9. 0 Installation hole

More information

Operating instructions

Operating instructions MA00929301 09/2015 Operating instructions ED10429002 ESYLUX GmbH An der Strusbek 40 22926 Ahrensburg Germany info@esylux.com www.esylux.com 1 Table of contents 1 Using the manual 8 2 Safety instructions

More information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor. Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits uminaire-integrated modules ENOTEC modular system 110046819 Control CD I 110046818 Control CD CO1 110046814 ensor ED HF1 110046813 ensor ED HF2 110046816 ensor ED PIR Function description The new ENOTEC

More information

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PPAD-C-HB-DALI-230V Product Guide Ceiling PIR HS presence detector DALI / DSI dimming Overview The PPAD-C-HB-DALI-230V PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

1 Safety instructions. 2 Device components. Presence detector. Operating instructions Presence detector Standard Art. No. 3361 WW Presence detector Standard Art. No. 3361 AL Presende detector Universal Art. No. 3361-1 WW Presende detector Universal Art. No. 3361-1 AL Operating instructions

More information

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features EBDHS-DD-LT30 Product Guide Ceiling PIR HS presence detector DALI / DSI, low temperature Overview The EBDHS-DD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. Product Guide LPCMPIRDSI Ceiling PIR presence detector DALI / DSI dimming Overview The LPCMPIRDSI PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

1. Basic safety information 3 2. Proper use 3

1. Basic safety information 3 2. Proper use 3 307146 03 EN Presence detector thepiccola P360-100 DE WH 2090200 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Device description 4 4. Installation and connection 4 Installing the presence

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 4 START-UP All parameter settings are carried out via the ETS (Engineering Tool Software). The magnet provided can be used to activate the programming status for the physical address on the PD-ATMO 360i/8

More information

Connections, displays and operating elements C D E G H. Installing the control unit

Connections, displays and operating elements C D E G H. Installing the control unit 1 2 3 GB Control unit 0-10 V REG-K/3-gang with manual mode Operating instructions Art. no. MTN646991 ¼ DANGER Risk of fatal injury from electrical current. All work on the device should only be carried

More information

0701 CO Light, HVAC, Monitoring, Brightness

0701 CO Light, HVAC, Monitoring, Brightness Using the application program Communication objects Product range: Product type: Manufacturer: Name: Order No.: Phys. sensors presence detector Siemens UP 258/21 presence detector 5WG1 258-2AB21 Functional

More information

Built-in HF Sensor for High Bay

Built-in HF Sensor for High Bay Daylight Monitoring RX TM Synchronisation control Ambient daylight threshold Built-in HF Sensor for High Bay HC419VRC/R Tri-level Control With Synchronisation and Remote Control Applications Occupancy

More information

Tebis application software

Tebis application software 5 Tebis application software STCC530E 2-channel presence detector 360 A faire Product reference Description TP device RF devices TCC530E Bi-zone presence detector TCC530E Output module: Dimmer Loads connected

More information

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

EBMHS (standard & slim-line PSU)

EBMHS (standard & slim-line PSU) Product Guide EBMHS (standard & slim-line PSU) Miniature HS PIR Presence Detector (luminaire fitting) Overview The EBMHS series of miniature PIR (passive infrared) presence detectors provide automatic

More information

UP 258E11 OPTISENS OFFICE

UP 258E11 OPTISENS OFFICE Product and functional description The UP 258E11 is a presence/motion detector with integrated 2-point light control. The UP 258E11 device communicates via KNX/EIB with actuators or other KNX devices.

More information

Detector switch - Dual Tech SCS

Detector switch - Dual Tech SCS 0 672 26 0 784 86 5 740 48 5 740 98 Page 1. Use...1 2. Technical characteristics....1 3. Dimensions....1 4. Connection...1 5. Installation...2 6. Operation...2 7. Settings...2 8. Configuration....3 9.

More information

Product and Applications Description

Product and Applications Description Product and Applications Description The presence detector with a sensing range of 360 allows the automatic execution of control functions in the electrical system by detecting movements. For example,

More information

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual

More information

KNX/EIB - Product database - Application description

KNX/EIB - Product database - Application description KNX/EIB - Product database - pplication description Theben HTS KNX/EIB Product Database V3.2 for Theben HTS presence detectors ECO-IR 360EIB-C ECO-IR 180EIB-C ECO-IR DUL-EIB compact office EIB compact

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

Tri-level Control Sensor

Tri-level Control Sensor Daylight Monitoring Photocell Advance TM One-Key Commissioning Ambient daylight threshold oop in oop out Tri-level Control Sensor HC038V HCD038 Detached inear Version with Remote Control Applications Occupancy

More information

Devices for Special Applications

Devices for Special Applications Overview AP 2/11 UP 2/12 N 26/02 UP 28/11 UP 28/21 N 342 AP24/02 GE 22 GE 23 GE 24 UP 2 AP 2 Control Integrated constant light level control 1-channel 3-channel -- -- -- 1-channel -- -- 1-channel -- 1-channel

More information

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version) Dimming Function MC00V (Standard Version) MC00V R (Reinforced Version) Dimming Introduction Automatic dimming when used in combination with 1-V dimmable LED drivers or ballasts. Built-in adjustable daylight

More information

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR 8. SPECIFICATION LOAD 6 Amps fluorescent and incandescent lighting. 3 Amps compact fluorescent lighting. 3 Amps low energy lighting. 3 Amps low voltage lighting (switch primary of transformer). Switch

More information

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR GB Contents 1. GENERAL 1 1.1 KNX bus basics 1 1.2. Overview 1 1.3 Symbols 1 2. OCCUPANCY DETECTOR BASICS 2-3 2.1 Introduction 2 2.2 Motion detection with the B.E.G.

More information

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDSPIR-HB-AD High bay PIR presence detector 1-10V dimming Overview The EBDSPIR-HB-AD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components pure white Order-No. : 0317 02 colour aluminium Order-No. : 0317 04 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure

More information

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

The two type sensors are innovative and active motion dimmable LED drivers or ballasts. Dimming Function (Standard Version) R (Reinforced Version) Introduction Automatic dimming when used in combination with 1-V The two type sensors are innovative and active motion dimmable LED drivers or

More information

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5 Lighting Control Sensor Daylight 2 Daylight+Motion 3 Daylight+Motion+Control 4 Daylight+Motion+Control IP67 5 Daylight SL01A Daylight+Motion+Control SM03A Daylight+Motion SM05 With the increasing interests

More information

D-Tect 2 GJD300 Quad PIR Movement Detector

D-Tect 2 GJD300 Quad PIR Movement Detector D-Tect GJD0 Quad PIR Movement Detector Package Contents 3. Package Contains: x D-Tect x Drilling template for fixing holes x Allen Key 3 x 3.75mm wall plugs 3 x 3.75mm screws x Spare Sliding Curtains x

More information

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

GE Lighting. Lighting Controls. DALI Digital Lighting Controls GE ighting ighting Controls I Digital ighting Controls the I Protocol Multi-functional control of I-ready GE uminaires 1-1 to I converters available for analogue luminaires I CB Type 2 - complete programmable

More information

North America Version / Dimming Function. Introduction

North America Version / Dimming Function. Introduction orth America Version / Dimming Function /OFF Introduction Automatic switching or dimming when used in combination with 1-10V dimmable ED drivers or ballasts. Built-in daylight. 1-10V interface can match

More information

Daylight harvest function to regulate light output for maintaining required lux level

Daylight harvest function to regulate light output for maintaining required lux level TM Ambient daylight threshold oop in oop out HF Aisle Sensor Trilevel Control with Daylight Harvest and Remote Control Applications Occupancy detector with trilevel dimming control suitable for below applications:

More information

Sensors and Detectors

Sensors and Detectors 12/12/2017 Sensors and Detectors - Clipsal by Schneider Electric Sensors and Detectors Add sensors and detectors to make an environment smarter and more efficient. C-Bus sensors and detectors allow environmental

More information

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MWS6-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS6-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual

More information

User Manual 120/240/300 Outdoor Motion Detector

User Manual 120/240/300 Outdoor Motion Detector User Manual 120/240/300 Outdoor Motion Detector Swiss Garde 4000 Warning! - Any work on the main power supply must only be completed by trained specialists. - The product must be installed in accordance

More information

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm). Flush Mount PIR Motion Sensor PIR 1-10V Dimming with Remote Control Mechanical Structure 70mm 64.7 4 56 68.1 73.3 Ø85 3 (1) Sensor inset (2) Lens pluggable Infrared receiver 1 Photocell LED indicator (3)

More information

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions Art.-No.: AS..1280-1.. Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

Presence detector Komfort attachment Installation Instructions

Presence detector Komfort attachment Installation Instructions Presence detector Standard attachment Order no.: 0304 0x Order no.: 0319 0x System information This unit is a product of the Instabus-EIB-System and corresponds to the EIBA Guidelines. Detailed technical

More information

LUX Hardwired - Installation Notes

LUX Hardwired - Installation Notes Ness LUX wired PIR with Nightlight Quad element pyro sensor 15m x 15m wide angle coverage Look down Creep Zone Selectable Standard and Pet Aware modes Adjustable sensor mask for No Creep and Pet modes

More information

Description of the application programme for KNX occupancy detectors version 3.1

Description of the application programme for KNX occupancy detectors version 3.1 Contents 1. General...1 1.1 Basics for the KNX/EIB BUS...1 1.2 Application versions...1 1.2 Application versions Switchgear application Version 3.1: BEG_SWI_HKL_V3.1 Part numbers: 1.3 Symbols used...1

More information

Direct Dim Microwave Presence/Absence Detector

Direct Dim Microwave Presence/Absence Detector Product Guide MWS3A-DD Direct Dim Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Fixing 3 4 Installation 3 5 Fixing

More information

False Ceiling HF Sensors

False Ceiling HF Sensors False Ceiling HF Sensors HC009S/EXT HC018V/EXT HC019V/EXT Applications Ideally suited to retrofit projects where the luminaire is too small to accomodate the sensor internally, this motion sensor can be

More information

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL THE EVOLUTION OF CONTROL APP & CLOUD PORTAL APP MAIN APP FUNCTIONS EMERGENCY Facilitates the work of installers and company maintenance operators. Allows control of the functions of all lights of the system.

More information

Passive infrared ceiling sensor

Passive infrared ceiling sensor Passive infrared ceiling sensor 88 Description Control and command device, powered by the SCS BUS, with two different sensors, the combination of which enables managing the light level inside the room,

More information

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6 307214 1103107701 EN Presence detector theronda S360-101 DE WH 2080565 theronda S360-101 DE GR 2080566 theronda S360-101 AP WH 2080555 theronda S360-101 AP GR 2080556 1. Product characteristics 4 2. Safety

More information

Tri-level Control HF Sensor

Tri-level Control HF Sensor Daylight Monitoring TM Ambient daylight threshold Loop in Loop out Tri-level Control HF Sensor HC403VRC-KD Detached Version with Daylight Monitoring Applications Occupancy detector with tri-level dimming

More information

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels MS3602CH 2 Channel Motion Sensor For Outdoor Use Wall & Ceiling Mounted Quick & Easy Installation 2 Channels Channel 2 Distance Wiring Diagram 220-240V ~ 50Hz 14A Max. (cosø=1) 3000W for incandescent load

More information

SWITCHLITE MRE DDM ADJ

SWITCHLITE MRE DDM ADJ 96239889 SWITCHLITE MRE DDM ADJ Front features Mounting Bezel Back features Retaining Spring Power Input & Switched Output Connector (Channel 1) Sensor Lens which covers... Microwave Sensor IR Receiver

More information

Detailed operating instructions

Detailed operating instructions MA00613903 Detailed operating instructions MD 360/8 Basic EB10430404 MD 360i/8 Basic EB10430428 MD 360/24 Basic EB10430848 MD 360i/24 Basic EB10430862 MD 360/8 Basic SMB EB10430497 MD 360i/8 Basic SMB

More information

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500 0073-1-7613 Rev. 01 06.2011 KNX Technical Reference Manual Busch Präsenz tech 6131/10-500 6131/11-500 KNX Technical Reference Manual Busch Präsenz tech 1 Safety instructions Work on the 230 V power supply

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-A-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-A-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

SENSA MRE DDM MR

SENSA MRE DDM MR 96239831 SENSA MRE DDM MR Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring and fixing 3 4 Programming 6 5 Wiring diagrams 8 6 Detection pattern diagrams

More information

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MWS3A-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS3A-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual

More information

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector 307021 3. Proper use EN Motion detector themova P360-100 UP WH 1030600 themova P360-100 UP GR 1030601 The motion detector is intended for interior. The motion detector is eclusively intended for the use

More information

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX.. Presence detector PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX.. D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 32 Operating Manual

More information

FSTR- Series Microwave Motion Sensor (MSSD) Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten. Introduction

FSTR- Series Microwave Motion Sensor (MSSD) Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten. Introduction Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten Introduction Unique split design makes it suitable to fix within lamps which have limited space. Automatic dimming when used in

More information

SCS motion sensors Surface/wall mounting - PIR

SCS motion sensors Surface/wall mounting - PIR IP55 Page 1. Use.....................................1 2. Technical characteristics................1 3. Dimensions............................1 4. Connection.............................1 5. Removal................................2

More information

e-sense move dali Manual

e-sense move dali Manual e-sense move dali Manual Page Content The Basic Function of Move...4 5 Programming RF-signal...6 7 Erase RF-signal...8 Pre-set Scenes...9 Receiving RF-signal Options...10 Reduced Power, Standby Dimming

More information

Movement controller comfort, Flush-mounted (Up) xx, xx

Movement controller comfort, Flush-mounted (Up) xx, xx Order no.: 752615xx 752616xx The instabus movement controller comfort is designed for internal use and is pushed onto a flushmounted bus coupling unit (BCU). It reacts to heat movements triggered by persons,

More information

Analogue Dimming Microwave Presence/Absence Detector

Analogue Dimming Microwave Presence/Absence Detector Product Guide MWS3A-AD Analogue Dimming Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Fixing 3 4 Installation 3

More information

Tri-level Control HF Sensor

Tri-level Control HF Sensor Tri-level Control HF Sensor Standard Version Applications Occupancy detector with tri-level control suitable for indoor use. Suitable for building into the fixture: Office / Commercial Lighting Use for

More information

PIR movement and presence detectors 10 A

PIR movement and presence detectors 10 A PIR movement and presence detectors 10 A Hotel room energy-enabling units ighting control in corridors (for hotels, offices and hospitals) Offices, swimming baths and schools SЕRIES Staircase light control

More information

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector EN Motion detector themova S360-101 DE WH 1030565 themova S360-101 DE GR 1030566 themova S360-101 AP WH 1030555 themova S360-101 AP GR 1030556 1. Product characteristics 307067 Passive infra-red motion

More information

Loop out. Ambient daylight threshold

Loop out. Ambient daylight threshold transmitter 0 ULT - HC9V Type of Product: Description: Finish: Warranty: Tri-level Dimming Control Microwave Motion Sensor Colour White years Daylight threshold Stand-by period Stand-by dimming level Antenna

More information

Integrated SensorDIM LED Driver Daylight Monitoring Version

Integrated SensorDIM LED Driver Daylight Monitoring Version TM Integrated SensorDIM ED Driver Daylight Monitoring Version Model: HEC730 with HRC-0.1 ED + ED - ED current selection 0 9 Daylight threshold Antenna module connector Buzzer ] PUSH Extended antenna 99

More information

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR 307079 EN Motion detector themova P360 KNX UP WH 1039600 themova P360 KNX UP GR 1039601 1. Product characteristics 4 2. Safety 5 3. Proper use 6 4. Function 6 5. Detection area 10 6. Installation 13 7.

More information

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55 96239823 SWITCHLITE MRE SLD MAN 96239821 SWITCHLITE MRE SLD IP55 Overview The SWITCHLITE MRE SLD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Microwave Sensor. Basic Microwave Sensor. Energy Saving Motion Sensor. Introduction Features Technical Specification. 3 Dimensions

Microwave Sensor. Basic Microwave Sensor. Energy Saving Motion Sensor. Introduction Features Technical Specification. 3 Dimensions Energy Saving Motion Sensor Introduction Features Sensor detection pattern 2 3 Dimensions Function Guidelines Installation and Wiring Wiring diagrams Set up guide About One-LUX Get in touch 4 5 6 Introduction

More information

Detailed operating instructions

Detailed operating instructions MA00744002 Detailed operating instructions MD-FLAT 360i/8 RW EP10427886 MD-FLAT 360i/8 SW EP10427893 MD-FLAT 360i/8 RB EP10428074 MD-FLAT 360i/8 SB EP10428081 MD-FLAT-E 360i/8 RW GST EP10427862 MD-FLAT-E

More information

Automatic switch attachment Standard Installation Instructions

Automatic switch attachment Standard Installation Instructions System 2000 Order no.: 1300 xx 1301 xx Function The System 2000 automatic switch attachment Standard responds to movements of heat sources and triggers a switching action. The light remains on as long

More information

Use of the application program

Use of the application program Contents overview Use of the application program Use of the application program 1 1. Functional description 2 Switching on / off 2 Dimming brighter / darker 2 Dimming value (8 bit) 3 Status Switching (1

More information

Save energy. ARGUS presence detectors

Save energy. ARGUS presence detectors Save energy Ef cient energy use 2 Keeping energy costs down Increasing energy costs and growing awareness of the environment in modern buildings management now mean that more innovative solutions for efficient

More information

B.E.G. LUXOMAT. Find the right detector.

B.E.G. LUXOMAT. Find the right detector. B.E.G. LUXOMAT Find the right detector www.beg-luxomat.com B.E.G. B.E.G. SMARTPHONE APP The new B.E.G. remote control app 92726 Rapid programming by smartphone The B.E.G. remote control app is the easiest

More information

2. Safety. 4. Function

2. Safety. 4. Function EN Presence detector KNX AP WH 2089550 KNX AP GR 2089551 KNX FLAT DE WH 2089560 KNX FLAT DE GR 2089561 1. Product characteristics 307337 1103092301 Passive infrared presence detector for ceiling Circular

More information

Sensors SR Programming manual

Sensors SR Programming manual Sensors SR510000 Index 1 GENERAL DESCRIPTION... 3 2 TECHNICAL INFORMATION... 4 3 PROGRAMMING... 5 3.1 APPLICATION PROGRAM INFORMATION... 5 3.2 COMMUNICATION OBJECTS TABLE... 5 3.3 OBJECTS DESCRIPTION...

More information