TULEKAHJU TEATENUPP HOONEAUTOMAATIKASÜSTEEMID AAR ÜLO KALA. Page 1. OSA VI-III ATS kesk ja lisaseadmed GKS VKS AAR0130 ÜLO KALA
|
|
- Janel Richardson
- 6 years ago
- Views:
Transcription
1 HOONEAUTOMAATIKASÜSTEEMID AAR OSA VI-III ATS kesk ja lisaseadmed GKS VKS ÜLO KALA 1 TULEKAHJU TEATENUPP PAIGALDATAKSE IGA VÄLJUMISUKSE JUURDE PAIGALDATAKSE 1,5 M PÕRANDAPINNAST NUPU KAUGUS ANTUD EVAKUATSIOONIPIIRKONNA VÄLJUMISUKSE KAUGEIMAST PINNAST EI TOHI ÜLETADA 30 m NUPPU EI TOHI KASUTADA MILLEKSKI MUUKS KUI AINULT TULEKAHJUTEATE EDASTAMISEKS NUPUD VÕIVAD OLLA KAS PURUSTATAVA KLAASIGA VÕI VÕTMEGA TAGASTATAVAD NUPP VÕIB OLLA KAS ADRESSEERITAV VÕI MITTEADRESSEERITAV NUPPE TOODETAKSE MITMES VÄRVITOONIS: 2 PUNANE TULEHÄIRE KOLLANE GAASIKUSTUTUSE KÄIVITUS HALL SUITSUÄRASTUSE KÄIVITUS SININE TEHNILINE ALARM Page 1
2 KONVENTSIONAALNE KESKSEADE ESSER BMZ 80 3 ADRESSEERITAV KESKSEADE Compact housing 450 x 320 x 185 mm Compact housing plus 1 x Extension housing 450 x 640 x 185 mm Compact housing plus 2 x Extension housing 450 x 960 x 185 mm Upright cabinet Steel sheet housing 700 x 2000 x 525 mm Option for all Panels 4 Page 2
3 KESKSEADME JUHTIMINE Single zone indicator unit (GEA) Common display FIRE Common display PRE-ALARM Common display TROUBLE Common display disconnection Alphanumeric display Key switch Operating elements Function keys and keyboard Opening for Programming connector must locked with dummy plug for ESD protection 220 V TOIDE ATS keskseade peab saama toite eraldi fiidri või eraldi automaadi kaudu. Eraldi automaat peab olema selgelt tähistatud ja teistest automaatidest eraldi. Hoonetes kus on maanduse kaitsereleed tuleb paigaldada eraldi relee ATS süsteemile. ATS toite kaitseautomaat või sulavkaitse peab olema varustatud selge punase kirjaga ATS TOIDE. Alati peb olema korralik keskseadme maandus. (näiteks ESSER keskseadmed süütavad halval maandusel kollase tule teatega ground loop fault. Kasutatada tuleks alati spetsiaalset toitekaablit näit. NYM 3 x 1.5 mm2 või sarnaste tehniliste andmetega kaablit. Paigaldus peab vastama kõigile kehtivatele elektrisüsteemide ehitusele esitatavatele nõuetele. 6 Page 3
4 ANDURITE JA KORDUSPANEELIDE ÜHENDAMINE (Standard) (Standard) (Relay) EP6 1 + EP6 1 Option 6 1 BR1 = n.o. (default) BR1 = n.c. OUT5 EM2 OUT5 EM2 - OUT5 BR1 2 IN4 C3 IN4 C3 IN4 C3 IN4 / B - A - A + C3 / B + B - B + FACP 8000C/M, IQ8Control, 8007 X24 FACP8000C/M, IQ8Control, 8007 Last device BR8 BR9 Last device LCD-IP FAS Basic module X8 B RS485 A UB ext + GND RS V B A + - J2 J3 J4 J6 J5 J7 J2 J3 J4 J6 J5 J7 max. 1000m J2 J3 J4 J6 J5 J7 J2 J3 J4 J6 J5 J7 7 KESKSEADME ÜHENDUS SUURSILMUSEGA SUURSILMUS- MULTIFUNKSIONAALNE AHEL LISAPANEEL FDOP max. 3,5 km SUURSILMUS esserbus esserbus transponder esserbus transponder 8 3 Page 4
5 AVASTUSTSOONID SUURSILMUSES 9 SOPISTUS EHK SPUR A B 10 Page 5
6 TULETÕKKETSOON JA AVASTUSTSOON 3 2nd KORRUS floor 2 KORRUS 1st floor 1 Ground KORRUS floor 4/1 4/2 4/3 4/4 3/1 3/2 3/3 3/4 1/1 1/2 1/3 1/4 TREPIKODA Stairwell 2/3 2/2 2/1 11 TULETÕKKETSOON Fire TSOON section A A Fire TSOON section B B TULETÕKKETSOONID ON EHITUSLIKULT MÄÄRATUD PIIRKONNAD HOONES MIS ON ERALDATUD OMAVAHEL TULEPÜSIVATE VAHESEINTE, USTE JA MUUDE TÕKENDITEGA TULETÕKKETSOON EI PEA KOKKU LANGEMA AVASTUSTSOONIGA. TULETÕKKETSOONIS VÕIB OLLA MITU AVASTUSTSOONI AVASTUSTSOONIS EI VÕI OLLA MITUT TULETÕKKETSOONI 12 Page 6
7 SUURSILMUSE LIIKMED LRS compact/eb IQ8Control transponder transponder 4 tsooni/ 1 tsoon 2 releed transponder 32 LED transponder 12 Releed transponder FSA esserbus kustutuspaneel 8010 LED INFOPANEEL TRANSPONDER RZT 8000 Tehnilise alarmi moodul IQ8Tam 13 TEISE TOOTJA ANDURID VÕRK (RS485) FACP 3008 Gateway Indicating and operating Panel intruder / fire FACP 8000C esserbus WINMAG Serial essernet Interface essernet FOC Fibre optical cable FACP IQ8Control C FOC IAP 5008 C IAP esserbus max. 1 km Repeater max. 1 km esserbus -PLus 14 Page 7
8 VÕRGUÜHENDUSED essernet not used! not used! not used! not used! L1 + L1 - L2 + L2 - essernet module essernet module L2 + L2 - L1 + L1 + L1 - L2 + L1 - L2-15 FIIBEROPTILINE VÕRK Length / attenuation refer to specified optical fibre type above Vcc RxD T R PIN 3 PIN 8 Panel 1 Panel 2 T R Vcc RxD PIN 3 PIN 8 FOC converter / UBext. GND essernet module Conventional essernet wiring or connection via second fibre optics cable +UBext. GND 4 essernet module Fibre Optics Link FOC FOC essernet essernet Fibre Optics Link FOC FOC Fibre Optics Link 16 FOC FOC Page 8
9 Web-X WebCam GRAAFILINE TARKVARA Notifikation Internet PC- Netzwerk ESSER NET modem ISDN IGIS LOOP access control video matrix emergency exit control 17 RS 485 serial GRAAFILINE LIIDES 1 EKRAANIGA 2 EKRAANIGA WINMAG 18 Page 9
10 STANARD LIIDES PLAAN SÜNDMUSE event text and TEKST measure JA JUHISED STRUK- TUUR 19 SÜNDMUSTE LOGI 20 Page 10
11 ALARMSEADMED ANDUR SISSEEHITATUD SIREENI VÕI VALJUHÄÄLDIGA SPETSIAALNE ALARMSEADE 21 HELIRÕHK EFFEKTIIVNE HLIRÕHK ON ÕHUMOLEKULIDE POOLT PÕHJUSTATUD RÕHK MIS TEKIB NENDE VÕNKUMISEL (HELILAINE) INIMKÕRV SUUDAB VASTU VÕTTA HELISID RÕHUGA 0 (KUULDELÄVI) KUNI 120 SAGEDUSEL 1000 Hz. SEE VASTAB HELIRÕHU MUUTUSELE 20N/m2 (= Pa) VÕI SIIS 1: 1,000,000 HELIRÕHU JAOKS (Lihtsuse mõttes arvutataksegi helirõhku logaritmilistes suurustes( ). KESKKOND ELURUUMID ÖISEL AJAL ERALDI BÜROORUUMID AVATUD BÜROORUUMID LAOHOONED EL. TÕSTUKITEGA LAOHOONED DIISELTÕSTUKITEGA TOOTMISHOONED JA LINNATÄNAV SURUÕHU PIIKVASAR 10 M KAUGUSELT POLITSEI, TULETÕRJE JNE SIREEN 10 M REAKTIIVMOOTOR 10 M HELIRÕHU TASE 1) < > Page 11
12 MINIMAALNE HELITUGEVUS EN 54-3, OSA JÄRGI KIIRGUSNURK DIN SIGNAAL MADAL TOON 730 Hz KESKM. TOON 830 Hz KÕRGE 970 Hz HELIROHK KUULDEPUNKTIS 92 1m 72 10m ~ -20 HELIRÕHU MUUTUS SÕLTUVALT ALLIKA KAUGUSEST: L ( ) = 20 x log (r2 [m] / r1 [m]) KUS: r1 = 1m algne kaugus r2 = 20m uus kaugus ALARMSEADMETEL ON TAVALISELT ANTUD HELIRÕHK 1 M KAUGUSEL SEADMEST. IGA KORD KUI KAUGUS SUURENEB 2 X VÄHENEB HELIRÕHK 6 Db. 24 Page 12
13 Audible signals / Speech output Audible signals (Example) Demo Signal component Description of signal Duration [s] Tone 1 (GB) FP Telecoms BS 5839 Pt1-Tone 1 Alternating signal tone, Fequency 800 / 970 2Hz 4,00 Tone 2 (GB) FP Telecoms BS 5839 Pt1-Tone 2 Alternating signal tone, Frequency 800 / 970 1Hz 4,00 Tone 3 (GB) FP Telecoms BS 5839 Pt1-Tone 3 Cyclic signal tone, Frequency 970 1Hz 0,5 s 4,00 Speech outputs Demo Signal component Description of signal Duration [s] Phrase 6 This is a fire alarm. Please leave the building immediately by the nearest available exit. 5,27 Phrase 7 Attention please. This is an emergency. Please leave the building by the nearest available exit. 5,82 Phrase 8 An incident has been reported in the building. Please await further instructions. 4,37 Phrase 9 This is a test message. No action is required. 3,18 25 Phrase 10 The emergency is now cancelled. We apologise for any inconvenience. 4,46 PLAHVATUSOHT Ex VASTAVUS EU Explosion Protection Directive 94/9/EC-ATEX 100a 26 Page 13
14 PLAHVATUSOHU TSOONID TSOON 2: Alad kus plahvatusohtlik atmosfäär võib tekkida harva ja lühikeseks ajaks TSOON 1: Alad kus plahvatusohlik kontsentratsioon tekib aeg-ajalt kindlasti TSOON 0: Alad kus on kogu aeg plahvatusohtlik atmosfäär 27 KUSTUTUSSÜSTEEMID KUSTUTUSSÜSTEMID GAASKUSTUTUS VEEKUSTUTUS PULBERKUSTUTUS HALOONGAASID LOODUSL. GAASID KEEMILIS. GAASID VEESPRINKLER VEEUDU KUSTUTUS AURUGA KUSTUTUS PÜROGEENAEROSOOLID KÄSIKUSTUTID 28 Page 14
15 GAASKUSTUTUSSEADE KUSTUTUSAGENDI BALLOON SUITSUANDURID DÜÜSID ALARMISEADE KÄSITSI RAKENDUS SEISKAMISNUPP KESKSEADE 29 GAASKUSTUTUSSÜSTEEM essernet esserbus Outputs Page 15
16 31 HALONI ALTERNATIIVID CO 2 FM-200 Argonite Inergen FE-13 Veeudu Pürotehnilised 32 Page 16
17 CO 2 Lõhnatu Atmosfääri koostisosa Minimaalne kustutuse kontsentr. 34% 5,800 kpa Survestus Pikk tühjenemisaeg - kuni 3 minutit Balloonid nõavad palju ruumi Võib kasutada lokaalsetes süsteemides 33 FM-200 HEA ASENDUS HALONILE Kiire ja efektiivne Ohutu inimestele Pole elektrijuht - ohutu kasutada el. seadmetel Keskkonnasõbralik Pikk säilitusaeg 34 Page 17
18 KUSTUTUSVIISID INERTGAASID 35 VAJALIK GAASI KOGUS (MAHT) Halon 1301 CO22 Inert Gaas 36 Page 18
19 ARGONITE Lõhnatu Vajalik kontsentratsioon 40% Alati gaasiline 20,000 kpa Survestus Pikk tühjenemisaeg - 60 sekundit Vaja palju balloone Märgatav ruumikulu Ekspluatatsioon kallis 50% ARGON 50% NITROGEN Inert gas blend - 52% N 2, 40% Argon, 8% CO 2 Primarily acts by O 2 dilution, to 10-12%, with some 37 Page 19
PÕLEMISE LIIGID HOONEAUTOMAATIKASÜSTEEMID AAR Page 1 OSA VI-II AUTOMAATNE TULEKAHJUSIGNALIS ATSIOON ( ATS ) ÜLO KALA
HOONEAUTOMAATIKASÜSTEEMID AAR0130 2010 OSA VI-II AUTOMAATNE TULEKAHJUSIGNALIS ATSIOON ( ATS ) ÜLO KALA 1 PÕLEMISE LIIGID PUU PÕLEMINE LAHTISE LEEGIGA 2 PUU PÜROLÜÜS Page 1 PÕLEMISPROTSESS PÕLEMINE ENERGEETILISED
More informationInstallation Instruction. Fire Alarm Control Panel IQ8Control C/M GB0 G G Technical changes reserved!
Installation Instruction Fire Alarm Control Panel IQ8Control C/M 79895.GB0 G 99044 0.009 G 059 GB Technical changes reserved! 009 Honeywell International Inc. Intended purpose This product must only be
More informationIQ8Control C Fire Alarm Panel
IQ8Control C Fire Alarm Panel State-of-the-art processor technology Maximum cable length for esserbus: 3,500 m Graphics supported, high performance programming tool Innovative alarm signalling by means
More informationBasic Fire Alarm SystemTraining. Arman Alnasar
Basic Fire Alarm SystemTraining Arman Alnasar Agenda Introduction to Esser 10 min Product Overview 5 min Control Panels 30 min Detectors 20 min Field Devices Alarm Devices 20min 10 min Management & Interface
More informationInstallation Instruction. Fire Alarm Control Panel Compact GB0
Installation Instruction Fire Alarm Control Panel Compact 798237.GB0 Technical changes reserved! G 214072 GB 10.2014 / AC 2014 Honeywell International Inc. Intended use This product may only be used for
More informationConcepts for the secure networking of large building complexes
Concepts for the secure networking of large building complexes Secure conditions: competence & responsibility Due to our extensive product portfolio, you can realize projects with us which, because of
More informationQuickstart Guide. Fire Alarm System Design
Quickstart Guide Fire Alarm System Design 2 Quickstart Guide Innovations The market for fire protection is a complex and constantly changing field in which many factors are to be considered during the
More informationTOOLS 8000 SOFTWARE FOR THE ENTIRE LIFE CYCLE OF YOUR FIRE DETECTION SYSTEMS
TOOLS 8000 SOFTWARE FOR THE ENTIRE LIFE CYCLE OF YOUR FIRE DETECTION SYSTEMS ONE SOFTWARE FOR ALL TASKS tools 8000 is the complete software tool for your fire detection systems. It accompanies you during
More informationOperation and Installation Instruction
Operation and Installation Instruction Extinguishing Control Computer 8010 19-Inch Design (Series 2 and Series 3) 798955.GB0 09.2007 G 200090 G 205064 GB Technical changes reserved! Intended purpose This
More informationEngineering Guideline. pac- Carriers Type Universal
Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art
More informationDCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS
DCA4 Digitally controlled Audio Matrix Product Specification March 2002 Current Thinking Document Number DDC DCA 7001 01 ACS Introduction Voice Alarm (VA) systems are the quickest way to evacuate the public
More information561-MB256 plus. Intruder alarm control panel. Performance features
561-MB256 plus Intruder alarm control panel The intruder alarm control panel 561-MB256 plus is designed for use in private and commercial zones and is highly suitable for setting up medium to large-sized
More informationFlexES Control Flexible solutions with the modular fire detection system
Flexible solutions with the modular fire detection system APPROVAL REPORT Project No: 0003042587 Class: 3010 Product Name: Examination for Approval of FlexES and Peripherals Product Type: Fire Alarm System
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationProduct Catalog Fire Alarm Systems
Product Catalog 0 Fire Alarm Systems Contents General Hints - General Information - Small Control Panels 8- ES Line/Conventional Compact/Single Loop Intelligent Addressable 8-0- IQ8Control Panels IQ8Control
More informationFeatures. Windows management system for hazard detection systems
Management Systems Features Compatible with Windows XP Professional SP2, Windows of 2003 servers and Windows Vista Modular construction and freely programmable Direct control of the network devices List
More informationfour Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1
four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2
More informationAll the security you need in one housing
IQ8Quad All the security you need in one housing IQ8Quad: The highlight of every fire detection scenario Fire detection technology 02 03 Safety is the result of efficiency and innovation This applies to
More informationDIVA8MG2. Compact PAVA System Master Unit. DIVA8 System
DIVA8MG2 Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Compact PAVA System Master Unit DIVA8 System DIVA8 system
More informationProduct Catalogue 2008 / Fire Alarm Systems
Product Catalogue 2008 / 200 Fire Alarm Systems Content General Details 1-6 1 2 Introduction Extensions 4 General Information Control Panels 7-8 Conventional Control Panels 8 - IQ8Control 10-2 System 8000
More informationtools 8000 The perfect all-round tool: tools 8000 Programming and service software for alarm systems Fire detection technology
tools 8000 The perfect all-round tool: tools 8000 Programming and service software for alarm systems Fire detection technology 02 03 The circle is complete: programming from installation to maintenance
More informationFire Alarm Control Panel IQ8Control C/M. Operation Instruction GB / AA
GB Operation Instruction 798950.10.GB0 04.2015 / AA Intended purpose This product must only be used for the applications outlined in the catalogue and the technical description and in combination with
More informationEngineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules
Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional
More informationAdvanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O Features Assembly System integration kit for Advanced Diagnostics PCS integration via Diagnostic Manager or device DTM Simple automatic
More informationEC-P Zone Intruder Alarm System
EC-P10 10-20 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 5 Remote Keypads... 5 EC-LED Remote Keypad... 5 EC-LCD Remote Keypad...
More informationIQ8Quad. The highlight of every fire detection scenario. Fire detection technology
The highlight of every fire detection scenario Fire detection technology 2 3 Safety is the result of efficiency and innovation four fire safety tasks, one device l This applies to fire alarm systems too,
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationIntelligent Addressable Fire Alarm System
Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of
More informationIntegrated Security Solutions
Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 3 Our integrated security solutions
More informationUser manual. KNXgal. version
User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with
More informationAdded password for IP setup page : Password must be in IP format!
NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP
More informationSIMATRIX NEO Modular Video Matrix
SIMATRIX NEO Modular Video Matrix SIMNEO-168 Modular Design Expandable up to 224 Video-Inputs, 32 Video-Outputs Up to 8 keyboards can be connected for control Multiple protocol driver for the direct control
More informationSecurity Alarm Systems
eclipse Security Alarm Systems Contents Introduction 2 System Configuration 3 Control Panels 4 Remote Keypads & Expanders 5 Communication Modules 6 Upload/Download 6 Specifications 7 Introduction Zeta
More informationTECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2
FEATURES: Closed Loop Design (Class A Wiring) Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationVoice Alarm Systems. Inform Selectively, Evacuate Safely Complete systems for voice alarm and fire detection technology
Voice Alarm Systems Inform Selectively, Evacuate Safely Complete systems for voice alarm and fire detection technology A New Dimension of Voice Alarm For use everywhere: The new voice alarm systems from
More informationFire Detection Systems Product Catalogue (Version )
Fire Detection Systems Product Catalogue (Version 2015-01) Version 2015-01 Product Catalogue Fire Detection Systems This product catalogue is intended for sales purposes only. For planning, installation,
More informationCall stations and extensions
Novigo Call stations and extensions PT2001-A1, PT2002-A1, PT2008-A1, PT2009-A1, PTO2001-A1, PTO2002-A1, PTO2003-A1, PTO2004-A1, PTO2005-A1, PTO2006-A1, PTO2008-A1 EN 54-16-certified alarm and business
More informationErbium-Doped Fiber Amplifier (EDFA) - MW Series
Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available
More informationEngineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS
Engineering Guideline pac-carriers Type 9195 for Yokogawa ProSafe-RS 2 Engineering Guideline / Yokogawa ProSafe-RS 06.06.2017 Integrated solutions for Yokogawa R. STAHL offers a wide range of customized
More informationConventional Fire Detection
SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct
More informationAn introduction to... Sigma
An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines
More informationGE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring
GE Security FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring Version v2-2 / September 2005 Aritech and Kilsen are GE Security brands. http://www.geindustrial.com/ge-interlogix/emea
More informationTri-Tech Medical Inc.
Submittal Data Sheet Project Information Project Number Approval Features The Master Alarm Panel conversion kits are designed to upgrade or retro-fit existing panels produced by several major brands. The
More informationMed Touch Master Alarm
Submittal Data Sheet Features The Powerex Med Touch Master Alarm Panel monitors and displays normal and alarm conditions from up to 128 remote medical gas source signals and provides alarm conditions as
More informationIQ8Quad. The highlight of every fire detection scenario. Fire detection technology
IQ8Quad The highlight of every fire detection scenario Fire detection technology 2 3 Safety is the result of efficiency and innovation l This applies to fire alarm systems too, as especially in this case,
More informationUser Manual. Security Systems Security System L208
User Manual Security Systems Security System L208 a Contents This hand book is a technical instruction document for the installation, commissioning and operation of the L208 intrusion alarm security system.
More informationOperation and Installation Instructions
Operation and Installation Instructions Fire Alarm Computer 8008 798 G930 08.005 G96946 GB Technical changes reserved! Intended purpose This product must only be used for the applications outlined in the
More informationFire control panels FC360
Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses
More informationSERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000
SERVICE INSTRUCTIONS FOR Fire Alarm System MINI-2000 Version 1.3 02.04.1998 Jari Ollila Tom Brunberg Oy Esmi Ab Copyright Oy ESMI Ab, 1991... 1998 The copyright to the documentation herein is the property
More informationOn the job around the clock 24/7: Fire detection systems
On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,
More informationFire control panel detect 3004 plus and accessories
Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be
More informationOperating Instructions
Operating Instructions ProVicom MT-65, MT-125 R. STAHL HMI Systems GMBH Im Gewerbegebiet Pesch 14 50767 Köln Version 1.7 Issue: 21.07.2008 R. STAHL HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc
More informationUEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers
Intrusion Systems UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers Up to 6 UEZ LSNs can be networked with system loop technology (SRT) Fire
More informationFC724 Fire control panel
FC724 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as
More informationCOMPACT FLAME CONTROLLER CFC 2000
COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationMicrophones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY
VIGIL Microphones VIGIL Unitouch combined data sheets LEADING THE WAY TO SAFETY Emergency Fire Microphone Certified to BSEN54 BFM400 is a range of fully monitored emergency fire microphones that provide
More informationFC724 Fire control panel
FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as
More informationThe EN54 Part 2 & 4 Fire System
Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54
More information(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS
(68.52) X June 2000 supersedes February 2000 vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS VIGILON SYSTEM ARCHITECTURE Repeat Panel Spur Manual Call Point T-breaker Alarm Sounder Max loop length 1000m
More informationFC722 Fire control panel
FC722 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as
More informationME 3011C / Alarm Indication / Quick Reference Guide
Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan
More informationOMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments
OMC-158-2 Ex interface unit Manual Version 1.2 August 2017 Author: Observator Instruments Revisions: 0.1 (October 2016) First issue 0.2 (December 2016) Prototype 0.3 (January 2017) Test release 1.0 (March
More informationCODESEC FIRE ALARM SYSTEMS. security technologies
CODESEC FIRE ALARM SYSTEMS security technologies AA402 ADRESSABLE FIRE ALARM CONTROL PANEL AA402 Electronic Addressable Intelligent Fire Alarm Control Panel Onboard one loop, 250 nodes per loop, Metal
More informationUniversal fault annunciator for panel mounting
Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs
More informationModBus DE-1 INSTALLATION AND USER MANUAL
ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN
More informationOperating Manual MS220DA
ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN
More informationIntelligent Single Loop Fire Alarm Control Panel
Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels
More informationRAEGuard 2 PID. User Guide
RAEGuard 2 PID User Guide P/N: H-D03-4001-000 Rev M February 2018 Contents Section 1: RAEGuard 2 PID User s Guide 1 General Information... 6 2 General Specifications... 8 2.1 RAEGuard 2 PID Specifications...
More informationGMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly
Operation Manual GMA200-MT Gas detection controller for mounting rail assembly GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231
More informationAnnunciator Unit SACO 16 D1. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open
More informationModel KBF 240 Constant climate chambers with large temperature / humidity range
Model KBF 240 Constant climate chambers with large temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Pressure
More informationContent. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 9. Packing list 9
Content Ⅰ General information 1 Ⅱ Product description 2 Ⅲ System description 3 Ⅳ Fault message 9 Ⅴ Packing list 9 Appendix: Network Connection Manual 1 About this manual This manual book describes the
More information600 Range Dialer Installation Manual. Version 1.0
600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract
More informationFire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63
Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.
More informationHRX Technical Manual. Version 1.2
HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire
More informationINDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...
GUIDE MANUAL INDEX 1- Introduction...5...5...6 4- The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops...7 4.2- The Control Panel 4 and 8 Loops...9 5- Installation Guide...10 5.1- Pre-Installation
More informationFlair 500 Series Annunciators
Flair 500 Series s Basics Flair Multi-Zone s (MZAs) are fully functional, flexible, programmable micro controller based alarm control panels. They can be used independently d or in conjunction with other
More informationAnnunciator unit. Application
Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally
More informationSolution F2. Fire Alarm Control Panels one step ahead.
Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution
More informationFire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features
Fire Control Panels UL, ULC, CSFM Listed; FM Approved* Features Compatible with Simplex 4120 Network Converts multiple 4120 network communications signals into a single fiber optic link to: Multiplex audio
More informationSyncro AS. Analogue Addressable Fire Control Panel. User Manual
Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level
More informationINSTRUCTIONS. Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH. 5.1 Rev: 4/
INSTRUCTIONS Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH 5.1 Rev: 4/17 INSTRUCTIONS Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH DESCRIPTION
More informationIntegrated Security Solutions
Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 2 Our integrated security solutions
More informationControl Panel User Guide
Fire Detection & Alarm System Control Panel V4.14 Control Panel User Guide (TO BE RETAINED BY USER) 26-0397 Issue 6 Fike s policy is one of continual improvement and the right to change a specification
More informationFCCP 200: Fume-cupboard indicator and monitor
Product data sheet 3.1 43.170 FCCP 200: Fume-cupboard indicator and monitor How energy efficiency is improved Display and interface for safe, energy-efficient monitoring of fume cupboards, pressure zones
More informationFire and Gas Monitoring Panel ST7-HV
Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content
More informationControl Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)
Fire Detection & Alarm System Control Panel (Suitable for TWINFLEX pro control panels from V2.00) Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER) 26-0959
More informationSiemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation
Sinteso Cerberus PRO FDA241, FDA221 ASD Aspirating smoke detector Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Patented technology Early
More informationFC723 Fire control panel
FC723 Fire control panel FS720 series (IP5) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 756 addresses Processes
More information4100U Fire Indicator Panel Australian Wiring Diagrams
Fire Fire Indicator Panel ustralian Wiring Diagrams ustralian Installation Wiring Diagrams Manual LT0432 Iss 1.04 General Each of these diagrams shows the wiring for a particular module or card or base
More informationE21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0
E21.X.01.6C-05 Operating Manual EB2000 MC page 1 Operating manual EB2000 MC EASYBUS-display with MIN-/MAX-alarm for up to 9 sensor modules Version 3.0 Pursuant to EN 50 081-1 and EN 50 082-2 for unlimited
More informationIntelligent 2 & 4 Loop Fire Alarm Control Panels
Intelligent 2 & 4 Loop Fire Alarm Control Panels Advanced has combined the latest technology with many years of fire experience, to create the Axis AX Series Intelligent Fire Alarm Control Panels. The
More information1.6. Installation instructions for Bridge Navigation Watch Alarm System (BNWAS 3000)
Technical Documentation BNWAS 000.. Installation instructions for Brid Navigation Watch Alarm System (BNWAS 000) WATCH ALARM MAIN UNIT REATER UNIT SELECTOR UNIT RESET UNIT Revisions Version Date Author
More informationTri-Tech Medical Inc.
Submittal Data Sheet Project Information Project Number Approval Features The Tri-Tech Area and Master Alarm Panel digitally displays gas pressure (1 psi increments) monitors and displays normal and alarm
More informationSecuriSens d-list Product Catalogue 2015
SecuriSens d-list Product Catalogue 2015 Content 1. Processor Units... 5 2. Cable d-list... 7 3. Single Sensor d-list... 8 4. Accessories d-list... 9 5. ATEX components d-list... 13 6. Spare Parts d-list...
More informationby Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE
WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE by Honeywell WINMAG, The Ultimate Vigilon Text And Graphics Software WINMAG offers the best possible integrated visual data and management solution
More informationSonos-SB Siren/Beacon
Sonos-SB Siren/Beacon Audible/optical signal transmitter compliant with EN 54-3 and EN 54-23 for fire alarm systems, in red and white. Wall mounting (category W) and ceiling mounting (category C) for indoor
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationMaster devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems
X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone
More information