CERTIFICATION MANUAL FOR NF PROGRAMMES MANAGED BY EUROVENT CERTITA CERTIFICATION: GENERAL PROVISIONS

Size: px
Start display at page:

Download "CERTIFICATION MANUAL FOR NF PROGRAMMES MANAGED BY EUROVENT CERTITA CERTIFICATION: GENERAL PROVISIONS"

Transcription

1 Certification body mandated by AFNOR Certification 48/50 rue de la Victoire PARIS Telephone: +33 (0) CERTIFICATION MANUAL FOR NF PROGRAMMES MANAGED BY EUROVENT CERTITA CERTIFICATION: GENERAL PROVISIONS Revision 0 February 2017 Approved by AFNOR Certification: 15 February 2017 Date of 1st application: 15 February 2017

2 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 2 of 31 CONTENTS PART 1 - GENERAL INFORMATION... 5 THE CERTIFICATION RULES... 5 SCOPE AND CONDITIONS OF APPLICATION... 5 STAKEHOLDERS AFNOR Certification EUROVENT CERTITA CERTIFICATION Audit body Test body/laboratory Compliance Committee... 8 LIST OF TERMS... 9 PART 2 - REQUIREMENTS OF THE REFERENCE STANDARD REFERENCE DOCUMENTS Standards Additional technical specifications REGULATIONS QUALITY MANAGEMENT PROVISIONS MARKING Reference texts The NF logo and the marking process PART 3 - CERTIFICATION PROCESS HOW TO OBTAIN CERTIFICATION: THE ADMISSION PROCEDURE Submission of an admission application file Review of the application Implementation of checking operations Evaluation and decision MAINTAINING THE CERTIFICATION: MONITORING PROCEDURES Implementation of monitoring operations Evaluation and decision STATEMENT OF CHANGES Changes concerning the holder Changes concerning production entities Changes concerning the quality organisation of the manufacturing and/or marketing process Changes to the scope of certification: additional admission for a new model and/or new range Changes concerning the NF-certified product: Extension Maintenance application Temporary or permanent cessation of production of an NF-certified product CONDITIONS FOR STOPPING MARKING OR REMOVAL OF THE MARK IN THE EVENT OF SUSPENSION, WITHDRAWAL OR WAIVER 28 PART 4 - FINANCIAL PROVISIONS COST OF CERTIFICATION Obtaining certification Monitoring of certified products Annual fee for the right to use the NF mark TERMS OF PAYMENT Collection of payment Administrative costs Audits Tests... 31

3 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 3 of Additional checking operations... 31

4 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 4 of 31 This certification manual for NF programmes managed by EUROVENT CERTITA CERTIFICATION: General provisions were submitted to AFNOR Certification for acceptance into the NF certification system. It was approved by the legal representative of AFNOR Certification on 15 February It cancels and replaces any previous versions. MODIFICATIONS First date of application of the certification reference standard: 15 February 2017 Part Revision Date Modification made modified no /02/2017 Creation of Certification Manual

5 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 5 of 31 Part 1 - GENERAL INFORMATION The certification rules The NF mark certification rules, under the terms of the French Consumer Code, is made up of: - the General Rules of the NF mark, which set out the general structure and the conditions of use of the mark, the conditions of validity and the sanctions in the event of improper use of the NF mark; - this certification manual for NF programmes managed by EUROVENT CERTITA CERTIFICATION : General provisions, known as the certification manual, which describes the general working principles, the general requirements to be met and the procedures used to check compliance with these requirements; - the applicable technical certification reference standard, known as the technical reference standard, specific to the product(s) in question in each NF programme, which describes the technical requirements to be met and the procedures used to check compliance; - the reference documents listed in the certification manual and the technical certification rules, together with any additional technical specifications; and - the applicable price list. Scope and conditions of application All of the products that can be covered by NF certification managed by EUROVENT CERTITA CERTIFICATION are set out in the technical certification rules listed in Figure 1: Structure of the certification rules.

6 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 6 of 31 Figure 1: Structure of the certification rules General rules of the NF Mark Certification manual for NF programmes managed by Eurovent Certita Certification: General provisions One of the following technical certification rules : (*) Technical certification rules NF Domestic appliances using liquid or solid fuels Technical certification rules NF Radiators Technical certification rules NF Clay/ceramic chimney products Technical certification rules NF Bulk milk coolers on farms Technical certification rules NF Mobile liquid fuel heaters Reference documents (standards, regulations, etc.) T echnical certification rules NF Controlled mechanical ventilation Technical certification rules NF Heat pump Technical certification rules NF Domestic solar water heaters Price lists Technical certification rules NF Metal chimney ducts and liners Technical certification rules NF Multi-energy systems Technical certification rules NF Air purification devices (*) This list is not exhaustive The implementation of the products is not concerned by this reference standard. Certification is open to all applicants (or participants) whose products fall within the defined scope and are capable of meeting the technical requirements described in each technical certification rules.

7 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 7 of 31 Stakeholders The bodies involved in the procedure to grant the right to use the NF mark and to monitor the NFcertified products are specified below AFNOR Certification AFNOR owns the NF collective certification mark and has granted AFNOR Certification exclusive licensing rights. AFNOR Certification manages and coordinates the NF certification system, which particularly defines the NF mark governance rules and procedure. AFNOR Certification 11, rue Francis de Préssensé F LA PLAINE ST DENIS Cedex Tel.: EUROVENT CERTITA CERTIFICATION In accordance with the General Rules of the NF mark, AFNOR Certification has appointed the following body, known as the mandated body, to manage the NF certification programmes listed in a contract: EUROVENT CERTITA CERTIFICATION SAS 48/50 rue de la Victoire F PARIS Tel.: EUROVENT CERTITA CERTIFICATION, a certification body pursuant to the French Consumer Code, is responsible to AFNOR Certification for the operations for which it has been contractually appointed Audit body The audits performed as part of the certification process are carried out by auditors from one of the audit bodies listed in each technical reference standard. The participant or applicant must facilitate the operations that auditors are required to carry out in the context of their mission. Auditors have the right to inspect the applicant's or participant's facilities in order to perform their mission Test body/laboratory Product testing is carried out in accordance with the provisions set out by EUROVENT CERTITA CERTIFICATION and specified in the relevant technical certification rules.

8 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 8 of Compliance Committee Role If applicable, an advisory body is set up for each NF certification programme known as the Compliance Committee. Its role is to give its opinion on: - the technical certification rules and any changes to it, - the NF certification decisions (acceptance or rejection for new applications, and any sanctions relating to monitoring - warnings, suspensions, withdrawals), if applicable, - disputed cases, - the examination and implementation of recognition agreements relating to tests and audits, and - communication activities relating to the NF certification in question Working principle The names of the members of the committee are approved by EUROVENT CERTITA CERTIFICATION, each member being informed by EUROVENT CERTITA CERTIFICATION. The term of office for members is 3 years and is renewable by tacit agreement. EUROVENT CERTITA CERTIFICATION reserves the right to end a committee member's term of office if necessary. The Chairman of the Compliance Committee is appointed under the same conditions, following consultation of the Compliance Committee. The performance of the duties of a Compliance Committee member is strictly personal. However, if a member of the Compliance Committee is absent, they can be represented by a proxy appointed under the same conditions. The members of the Compliance Committee may not receive any payment for the duties performed. The committee members undertake to fulfil their duties with total impartiality and to keep the information disclosed to them confidential, particularly personal information. EUROVENT CERTITA CERTIFICATION takes the specific measures necessary to ensure the confidentiality of any applicant or participant files presented to the Programme Committee (except in the event of disputes/appeals) Members of the committee The members of the committee are selected in order to represent the various interested parties on an equitable basis and to guarantee their relevance: 1 Chairman (appointed from the Program Committee members) 2 Vice-Chairmen o 1 representative of AFNOR Certification o 1 representative from the mandated body: EUROVENT CERTITA CERTIFICATION Panel: Manufacturers, distributors (2 to 7 representatives) Representatives of the participants or applicants (or their agents) of the NF mark in question

9 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 9 of 31 Panel: Technical bodies, experts, laboratories (1 to 7 representatives) Representatives of technical bodies, particularly audit and test bodies Panel: Users, prescribers, consumers (1 to 7 representatives) o Representative(s) of prescribers o Representative(s) of consumer associations o Representative(s) of installers Working group For certain occasional activities not requiring that all of the Program Committee members meet, a working group may be created whose members are designated by name and selected from the members of the Program Committee. External individuals or professionals may be called upon to assist with these activities. The missions of this working group are specified by the Program Committee. Its powers are generally limited to preparing projects or proposals or supplying additional information on a given subject on behalf of the Programme Committee. List of terms Granting of the right to use the NF mark: Audit: Admission application: Additional admission application: Extension application: Brand Name application: Applicant: Authorisation granted by AFNOR Certification pursuant to the certification decision notified by EUROVENT CERTITA CERTIFICATION to an applicant to affix the NF mark on the product for which the application was submitted. Systematic, independent and documented process for obtaining objective evidence and evaluating it objectively to determine the extent to which the audit criteria are fulfilled (ISO 9000: paragraph ). First application Application whereby an applicant requests, for the first time, the right to use the mark for a product; he declares that he is acquainted with the technical certification rules and undertakes to comply with it. New product - New range - New factory belonging to a holder Application whereby a participant wishes to obtain the right to use the NF mark for a new product, a new range or a product/range manufactured at a new production entity. Changes to a product or range that is already certified Application whereby a participant requests the extension of the right to use the NF mark that he holds for a product or range the certified characteristics of which have been modified. New sales reference for a certified product Application whereby a holder requests the maintenance of the right to use the NF mark for a product intended to be marketed by a holder or a distributor under a different trade mark and/or sales reference with no modification of the certified or certifiable characteristics. Legal entity requesting the right to use the mark covered by the reference standard that undertakes to comply with said technical certification rules.

10 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 10 of 31 Distributor: Agent: Product: Admissibility: Maintain: Expell: Subcontractor: Suspension: Participant: Legal entity that introduces onto the market products certified by another participant. Legal entity or private individual located in the European Economic Area (EEA) that has the role of representing the applicant (or participant) located outside the EEA and has a written power of attorney from the applicant or participant stating that it can act on its behalf and specifying in what framework. Item resulting from a manufacturing method or process, originating from a given production unit, defined by a specific trade mark and/or sales reference with specific technical characteristics. Eligibility of the application for examination. Admissibility relates to the administrative and technical sections of the application. Decision notified by EUROVENT CERTITA CERTIFICATION whereby the participant's right to use the NF mark is renewed. Decision notified by EUROVENT CERTITA CERTIFICATION that cancels the right to use the NF mark. Legal entity that produces or assembles all or part of a product on behalf of an applicant or participant, with the applicant or participant being accountable for compliance with the certification requirements. Decision notified by EUROVENT CERTITA CERTIFICATION that temporarily and for a given period cancels the granting of the right to use the NF mark. Suspension may particularly be notified as a sanction or on the participant's application. Legal entity that has the right to use the mark covered by the reference standard, that undertakes to comply with said technical certification rules.

11 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 11 of 31 Part 2 - REQUIREMENTS OF THE REFERENCE STANDARD 2 Reference documents Standards The standards are listed in each technical certification rules Additional technical specifications If applicable, the additional technical specifications are set out in each technical certification rules. Regulations The products covered by a certification reference standard shall comply with the French regulations in force. They are manufactured to comply with all applicable directives and regulations. The awarding of the right to use shall under no circumstances substitute the legal responsibility of the company holding the right to use the NF mark by the responsibility of EUROVENT CERTITA CERTIFICATION. Quality management provisions These provisions apply to the applicant (or participant) of the mark and, as the case may be, to the production units of the main components of the product. The applicant (or participant) shall take every measure necessary to guarantee the product's continual compliance with the technical certification rules. This paragraph defines the minimum provisions that the applicant (or participant) shall set up in terms of quality management so that the products covered by the NF mark are produced at all times in accordance with this certification reference standard. The specific product requirements are defined in each applicable technical certification rules. These provisions encompass certain requirements of ISO 9001:2008 or 2015 designed to ensure product conformity. They do not imply certification of the quality management system. Accordingly, it is recommended that applicants and participants of the NF mark base the quality system set up for the products intended to be certified on the standard model defined by ISO 9001:2008 or 2015 and draw up the quality plans and quality manual in compliance with the requirements specified therein. The applicant/participant shall set up and maintain a quality management structure the existence and effectiveness of which are evaluated by EUROVENT CERTITA CERTIFICATION. For companies whose Quality Management System is certified by a body accredited by the EA (European Cooperation for Accreditation), the requirements of ISO 9001:2008 or 2015 are considered to be satisfied insofar as the company's Quality Management System applies to the products considered.

12 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 12 of 31 However, verification of the quality management provisions must include, at every audit, verification of compliance with the requirements of the chapters of ISO 9001:2008 or 2015 relevant to the product in question. The applicable chapters of ISO 9001:2008 or 2015 and the requirements specific to the NF mark are defined in the technical certification rules for each programme. The quality management documents are both: descriptive: o general organisation rules, o Procedures relative to the achievement and verification of quality. and technical: o definition of inspection procedures for products and equipment, o Definition of methods for measuring and verifying characteristics. Table 1: Approach for evaluating the additional requirements of ISO 9001:2015 compared to ISO 9001:2008 of of TITLE ISO 9001:2008 ISO 9001:2015 TITLE 4 Quality management system 4 Context of the organisation 4.1 a) to e) General requirements 4.4 Quality management system and its processes 4.2 Documentation requirements 7.5 Documented information General General 4.3 Determining the scope of the quality management system Quality manual Quality management system and its 4.4 processes General Control of documents Creating and updating Control of records Control of documented information 5 Management responsibility 5 Leadership 5.1 Management commitment General 5.2 Listening to customers Customer focus 5.3 Quality policy Establishing the quality policy Communicating the quality policy Quality objectives Quality objectives and planning to achieve QMS planning them 5.5 Responsibility, authority and Responsibility, authority and communication communication Responsibility and authority Organisational roles, responsibilities and Management representative authorities Internal communication 7.4 Communication 5.6 Management review 9.3 Management review 6 Resource management 7 Support 6.1 Provision of resources General Human resources 6.2 Human resources General 7.2 Competence Competence, awareness and training 7.2 Competence 7.3 Awareness 6.3 Infrastructure Infrastructure 6.4 Work environment Environment for the operation of processes Organisational knowledge 7 Product realisation 8 Operation 7.1 Planning of product realisation 8.1 Operational planning and control Customer communication Customer communication 7.3 Design and development 8.3 Design and development of products and services 7.4 Purchasing 8.4 Control of externally provided products and services 7.5 Production and preparation of service 8.5 Production and service provision

13 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 13 of 31 of of TITLE ISO 9001:2008 ISO 9001:2015 TITLE Control of service preparation and Control of production and service provision performance Post-delivery activities Validation of processes for production and service provision Control of production and service provision Identification and traceability Identification and traceability Preservation of product Preservation Control of changes 7.6 Control of monitoring and measuring equipment 8.2 Monitoring and measurement Monitoring and measuring resources General Measurement traceability Monitoring, measurement, analysis and evaluation Customer satisfaction Customer satisfaction Internal audit 9.2 Internal audit Monitoring and measurement of product 8.6 Release of products and services 8.3 Control of non-conforming product 8.7 Control of nonconforming outputs 10.2 Non-conformity and corrective action 8.4 Analysis of data Analysis and evaluation 8.5 Improvement 10 Improvement Corrective action 10.2 Non-conformity and corrective action Preventive action 6.1 Actions to address risks and opportunities 10.3 Continuous improvement In the event that the applicant/participant does not comply with the additional requirements of ISO 9001:2015 compared to ISO 9001:2008, the auditor will give notification of: - an area for improvement (if the non-compliance is found before 15/09/2018), and - a non-conformity (if the non-compliance is found before 15/09/2018). Marking Marking forms an integral part of the certification of a product and is used to ensure traceability. In addition the identification and traceability of a certified product, the marking of a product with the NF logo ensures better protection of the users and facilitates the defence of participants against misuse and fraudulent imitations. The reproduction and display of the AFNOR, AFNOR Certification and EUROVENT CERTITA CERTIFICATION logos are strictly forbidden without the prior approval of these bodies. The NF-certified product must bear a designation and identification distinct from non-nf-certified products. The participant must only use the NF logo to distinguish NF-certified products, without risk of any possible confusion with other products, particularly with NF-non-certified products. The participant authorises EUROVENT CERTITA CERTIFICATION to incorporate a link to the participant's website into its website. The following requirements apply unless otherwise specified in the technical certification rules Reference texts The French Consumer Code Article R of the French Consumer Code stipulates that: "When reference is made to certification in advertising, on labelling or the presentation of any product or service, and in sales documents of any kind relating thereto, the following mandatory information shall be provided to the consumer or user:

14 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 14 of 31 - the designation or corporate name of the certification body or the collective certification mark, - the name of the technical certification rules used, and - the manner in which the certification reference standard can be consulted or obtained." Article L of the French Consumer Code stipulates in particular that: "Any reference made to certification in advertising, on labelling or in the presentation of any product or service, and in sales documents relating thereto, shall be accompanied by clear information enabling the consumer or user to obtain easy access to the certified characteristics. technical certification rules shall be available for consultation either free of charge at the certification body, or by the sending of copies at the claimant's expense." General rules of the NF mark The purpose of the marking rules given below is to guide the participant in how to meet the regulations and the requirements of the NF mark. The general rules of the NF mark specify the conditions of use and validity and the sanctions in the event of improper use of the NF mark. Without prejudice to the sanctions laid down in the general rules of the NF mark, any incorrect statement of the certified characteristics and any fraudulent use of the NF logo expose the participant to lawsuits for fraud and/or misleading advertising. The information about the certified products is available on the website. This information includes: - identification of the product, - identification of the technical certification rules, - identification of the participant, - the certified characteristics. On request, EUROVENT CERTITA CERTIFICATION will provide the information about the validity of any given certificate. When the holder provides copies of certification documents to third parties, they shall be reproduced in full.

15 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 15 of The NF logo and the marking process The NF logo must ensure identification of every certified product. The participant undertakes to respect the graphic charter of the NF mark. The NF logo and graphic charter are available from the communications department of EUROVENT CERTITA CERTIFICATION. In order to meet the requirements of Article R of the French Consumer Code (see 2.4.1), the mark must be produced as follows, whenever this is technically possible: The dimensions of this marking and the means used are left to the participant's discretion provided the information is legible and subject to compliance with the NF mark graphic charter, which is available on request. References to the NF mark in the documentation (including in advertising materials, on websites, etc.) shall be made in such a manner that there is no risk of confusion between certified products and other products. The NF mark must be reproduced in the documentation and advertising materials in accordance with the conditions defined in the NF mark graphic charter. Reproduction of the NF mark, as defined in 2.4.2, on the participant's letterhead, is prohibited, unless the participant has been granted the NF mark for all of its products. It is recommended that the participant submit all documents (packaging, nameplates, sales documentation, etc.) containing the NF mark to EUROVENT CERTITA CERTIFICATION beforehand. In the event of a suspension or withdrawal decision, a non-conforming product or the waiving of certification, all reference to the NF mark on the products, in documentation or on the website must cease.

16 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 16 of 31 Part 3 - CERTIFICATION PROCESS 3 HOW TO OBTAIN CERTIFICATION: The admission procedure The certification acceptance process is as follows: APPLICANT EUROVENT CERTITA CERTIFICATION PROGRAMME COMMITTEE Compiling the application file: - application for the right to use the mark ( 3.1.1) - documents to be supplied ( 3.1.2) Review of the certification application ( 3.1.2) Corrective actions (if any) In-plant verifications - audit ( ) - sampling ( ) Tests, extrapolations and simulations ( ) Corrective actions (if any) Evaluation of audit and test reports ( 3.1.4) Possible examination of the application by the Programme Committee ( 3.1.4) Decision and notification ( 3.1.4) Follow-Up process

17 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 17 of 31 Any applicant (see definition in 1.4) wishing to obtain the right to use the NF mark on a product must first become familiar with the mark technical certification rules and declare its acceptance thereof. The application is drawn up on the applicant's letterhead as shown in the template (form 1a) and must be sent to EUROVENT CERTITA CERTIFICATION. If the product comes from a production unit outside the EEA, the applicant will appoint an agent within the EEA who jointly signs the application. It specifies the models and ranges covered by the application Submission of an admission application file Before submitting the application, the applicant shall first ensure that it meets the terms and conditions defined in the certification reference standard in relation to its product and sites. To support his application, the applicant undertakes to: - accept and comply with the terms and conditions set out and defined in the technical certification rules specific to the field of the products in question, and in particular: o submit products for certification in compliance with the regulations in force; o implement the changes required by the changes in technical certification rules that are communicated by the certification body; o use the NF mark under the conditions set out in the technical certification rules and for the certified products only; o act on the decisions made by the certification body for the certification (in particular define and implement corrective actions following a deviation noted or apply a sanction decision); - comply at all times with the certification requirements defined by the reference standard, including implementing the appropriate changes notified by the certification body; - ensure that the certified product continues to meet the requirements of the reference standard, in particular: o apply the internal production control system established efficiently in order to meet the requirements of the technical certification rules; o perform the inspections incumbent upon it so that the right to use the certification mark can be maintained; - take all necessary measures for: o the performance of evaluation and monitoring, including the supply of items with a view to the examination thereof, such as documentation and records, access to equipment, sites, areas, personnel and subcontractors of the client in question; o the investigation of complaints; o the participation of observers, if applicable; - make statements and provide information about the certification in accordance with the scope of the certification, in particular: o not submit counterfeit products for certification; o only use the trade name of the product submitted for the products certified in compliance with this technical certification rules;

18 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 18 of 31 - not use the certification of its products in any way that might be harmful to the certification body, or make any statements about the certification of its products that the certification body might consider to be misleading or unauthorised, in particular: o not use the NF mark in a manner that is improper or non-compliant with the certification reference standard in force; o not use the logo of the certification body; - in the event that certification is suspended, withdrawn or expires, to cease to use all means of communication that refer to the certification, comply with all of the requirements set out in the technical certification rules and take any other measure required; - in the event that a copy of the certification document is supplied to a third party, to reproduce it in its entirety or as specified by the technical certification rules; - when referring to the certification of its products in communication media such as documents, brochures or advertisements, to comply with the requirements of the certification body and/or the specifications of the certification programme and to send the certification body, at its request, all printed advertisements and catalogues that refer to the certification mark; - comply with all of the requirements that may be stipulated in the product certification programme relating to the use of conformity marks and information about the product; - investigate, record and retain a record of all complaints of which it is aware regarding compliance with the certification requirements; and: o make these records available to the certification body and auditors on request; o take all appropriate action in relation to such complaints and any imperfections found in the products that affect their compliance with the certification requirements; o document the actions taken; - inform the certification body in a timely manner of any changes that might affect its ability to comply with the certification requirements, in particular: o inform the certification body in a timely manner of any changes made to the basic file submitted at the time of application for the right to use the NF mark (particularly any changes made to the product(s) covered by the application); o inform the certification body of any permanent or temporary cessation of production covered by the certificate; - ensure, for all employees of the certification body or its approved subcontractors, that all of the safety measures relating to working conditions, sites and equipment comply with the local regulations in force; and - pay the certification costs (management, audit and testing, if applicable) in accordance with the price list in force. If the applicant (or holder) fails to obey these rules, then the examination of his application may be interrupted or suspended. In particular, reference may not under any circumstances be made to the NF mark before certification has been obtained.

19 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 19 of 31 The application shall be presented in accordance with the following conditions and templates: All documents must be submitted in French or English, except documents intended for the installer as well as the end user, which must be in French: Admission application form letter reproduced on the applicant's letterhead (form 1a) General information sheet (form 1b) List of models for which the NF mark application is being made (form 1c 1) File of admission tests in accordance with the provisions of each technical certification rules Technical file in accordance with the provisions of each technical certification rules Quality file in accordance with the provisions of each technical certification rules Review of the application The application and enclosed file sent to EUROVENT CERTITA CERTIFICATION are examined to ensure in particular that: - all the required documents are enclosed with the application file; - the products covered by the application are clearly defined and fall within the scope defined in the relevant technical reference standard; and - the documents in the technical file meet the requirements of the certification reference standard. EUROVENT CERTITA CERTIFICATION makes sure that it is in a position to respond to the application, and may request any additional information required for the admissibility of the application, if it is incomplete. In the event that certain documents do not meet the requirements of the certification reference standard, EUROVENT CERTITA CERTIFICATION informs the applicant Implementation of checking operations When the application is admissible, EUROVENT CERTITA CERTIFICATION organises the inspections and informs the applicant of the organisational procedures (auditor, audit duration, audited sites, laboratories, sampled products, etc.). Several types of inspection are carried out for the NF mark: - audits, particularly of production sites ( ), - admission tests on the products ( ), and - inspection of the technical and sales documentation.

20 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 20 of Initial admission audit The audit is performed by a EUROVENT CERTITA CERTIFICATION-approved auditor with the aim of ensuring that the measures defined and taken by the applicant during the design and/or manufacturing and/or marketing process comply with the requirements of this general reference standard and the relevant technical certification rules. The audit may be performed in the presence of an observer, who is bound by a confidentiality agreement. EUROVENT CERTITA CERTIFICATION may be required to permit the presence of said observer by standards or agreements to which it is a signatory. EUROVENT CERTITA CERTIFICATION will systematically inform the applicant that the observer will be present before the audit. EUROVENT CERTITA CERTIFICATION may also propose to the applicant that any other observer be present. If the applicant subcontracts part of its business, EUROVENT CERTITA CERTIFICATION reserves the right to send an auditor to the subcontractor's(s') premises on the basis of the same reference standard. The auditor(s): - Conduct(s) an audit designed to verify the existence and implementation of the quality provisions established by the applicant and their compliance with the requirements set out in the technical certification rules. This audit is carried out according to the general principles defined by ISO 19011:2012 regarding the quality audit, in particular relating to the scope of the audit and the details of the procedures, stipulated in an audit plan sent to the company before the audit begins. - Verify(ies) that the inspections have been carried out regularly for at least 3 months. - May have tests performed in his/their absence, in order to verify the conditions under which inspections are carried out on the audited site. These tests are preferably carried out on the type sampled for tests in the laboratory of the mark. - May take samples for tests in the laboratory of the mark in accordance with the sampling procedures set out in With the applicant's agreement, the auditors may make a copy of any document they consider necessary. If the applicant holds an ISO 9001 certificate, the audit report(s) must be made available to the auditor. If all of the requirements of the technical certification rules cannot be covered on the audited site, the applicant shall put in place the measures and resources necessary to evaluate all of said requirements. The duration of the audit (including preparation, performance of the audit, drafting the report and followup of corrective action, if any) is defined in each technical certification rules. Following the audit, the lead auditor establishes an audit report detailing the effectiveness of the quality organisation implemented, the strengths and weaknesses and a statement of nonconformities. It also includes a sampling sheet, if applicable. The applicant informs EUROVENT CERTITA CERTIFICATION of any corrective actions taken as a result of nonconformities identified during the audit within a period of one month unless otherwise specified by the lead auditor.

21 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 21 of Sampling for laboratory tests If the technical reference standard requires that samples are taken, this is done in accordance with the provisions set out. In addition: - a sampling sheet stating the samples taken is produced; - the applicant is responsible for sending the samples to the laboratory in charge of performing the tests; and - the applicant sends any sample requested by EUROVENT CERTITA CERTIFICATION to the laboratory in charge of performing the tests within the prescribed deadlines Admission tests Any sample taken are tested to check the certified performance as described in the relevant technical certification rules. Admission tests are performed by the mark laboratories (see 1.3.4) or in accordance with specific provisions set out in the relevant technical certification rules. A test report produced by the laboratory in charge of the tests is sent to EUROVENT CERTITA CERTIFICATION, which then passes it on to the applicant. If any nonconformities are identified, the applicant sends EUROVENT CERTITA CERTIFICATION an action plan setting out the root cause analysis, the extent of the deviation and the remedial and corrective actions Evaluation and decision EUROVENT CERTITA CERTIFICATION evaluates the test and audit report(s) in accordance with the procedures in force. The applicant must present, for each deviation, the actions taken or planned, including the schedule for the implementation of such action in the documented corrective action report. EUROVENT CERTITA CERTIFICATION analyses the relevance of the response and may request additional inspections to confirm that the corrective actions have been taken and are effective (additional audit(s) and/or testing). If necessary, EUROVENT CERTITA CERTIFICATION may anonymously present all of the evaluation results to the Programme Committee (see 1.3.5) for its opinion, where such a committee exists. On the basis of the results obtained during the examination of the application and any proposals made by the Programme Committee, EUROVENT CERTITA CERTIFICATION notifies the applicant of one of the following decisions: - Certification approved - Certification refused In the event that certification is refused, the applicant is given the reasons for the decision. A decision can be deferred in order to carry out additional examination of the application. The applicant may challenge the decision by submitting an appeal to EUROVENT CERTITA CERTIFICATION in accordance with the General Rules of the NF mark.

22 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 22 of 31 If certification has been approved, AFNOR Certification authorises the use of the NF mark, and EUROVENT CERTITA CERTIFICATION sends the applicant, who is now a mark holder, the NF certificate and a review of the evaluation notifying it of the decision. The certificate shows a validity end date of at most 3 years after the issue date, subject to compliance with the conditions for the renewal of the certificate set out in paragraph 3.2; it is renewed automatically at no cost under the same conditions. The exercising of the right to use the Mark is strictly limited to the products for which it was approved, in other words the duly defined products from the duly defined factories, manufactured under the conditions set out in the certification reference standard. The awarding of the right to use shall under no circumstances substitute the legal responsibility of the company holding the right to use the NF mark by the responsibility of EUROVENT CERTITA CERTIFICATION.

23 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 23 of 31 MAINTAINING THE CERTIFICATION: monitoring procedures EUROVENT CERTITA CERTIFICATION monitors the certified products from the time when the right to use the NF mark is granted, according to the process shown below: APPLICANT EUROVENT CERTITA CERTIFICATION PROGRAMME COMMITTEE Corrective actions (if any) In-plant verifications - audit ( Erreur! Source du renvoi introuvable.) - sampling ( ) Corrective actions (if any) Tests, extrapolations and simulations ( ) Evaluation of audit and test reports ( 3.2.2) Possible examination of the application by the Programme Committee ( 3.2.2) Decision and notification ( 3.2.2) Throughout the entire certification period, the holder shall: - comply with the requirements defined and the marking procedures; - keep the certification file up to date using the templates given; and - systematically inform EUROVENT CERTITA CERTIFICATION of changes to any of the characteristics of the certified product and/or its organisation likely to have an impact on the certification. Moreover, EUROVENT CERTITA CERTIFICATION reserves the right to proceed with any inspections (audits, tests, verifications, etc.) that it deems to be necessary further to: - a change to the certified product or the quality organisation of the production entities (production plant, production workshops, subcontractors' plants, etc.); and - complaints, claims, litigation, etc. regarding the use of the NF mark that have come to its attention.

24 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 24 of Implementation of follow-up operations The follow-up of NF-certified products includes examinations, analyses or testing of the products and audits of the sites involved in the manufacturing process. It also includes follow-up of the use of the mark and marking on the products, packaging and all marketing media. The follow-up procedures are based on the decisions made following the previous inspections Follow-up audit The provisions set out in apply to the applicant, who is now a mark holder. Follow-up audits are performed annually within one calendar year unless otherwise specified in the relevant technical reference standard. The checks performed primarily concern any modifications made since the previous audit that affect manufacturing or inspection procedures and any modification of the organisation of the quality management system. Verification of the quality management measures must include, during each audit, verification that the specific requirements of the NF Mark ( 2.4), the specific provisions of the relevant technical reference standard and the following chapters of ISO 9001:2008 or 2015 are observed, through processes defined by the holder: Table2: ISO 9001:2008 or 2015 requirements to be checked as a minimum during monitoring audits of of TITLE ISO 9001:2008 ISO 9001:2015 TITLE Identification and traceability Identification and traceability Preservation of product Preservation Follow-up and measuring resources Control of follow-up and measuring General equipment Measurement traceability Follow-up and measurement of product 8.6 Release of products and services 8.3 Control of nonconforming product 8.7 Control of nonconforming outputs 10.2 Nonconformity and corrective action Corrective action 10.2 Nonconformity and corrective action APPLICABILITY AND SPECIFIC FEATURES FOR NF CERTIFICATION Applicable in full Additional requirement for the NF mark: Records of complaints regarding certified products and the processing thereof shall be produced and retained. The other processes (and chapters of the standard) are verified during the various annual follow-up audits (by sampling) Sampling for tests at the mark laboratory The provisions set out in apply to the applicant, who is now a mark holder Follow-up tests The provisions set out in apply to the applicant, who is now a mark holder Inspection of technical and sales documentation The information contained in technical and sales documentation will be checked during audits and/or by regular inspection (websites in particular will be checked).

25 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 25 of Evaluation and decision The evaluation procedures are the same as for admission, as described in Depending on the results of all of the checks, EUROVENT CERTITA CERTIFICATION may decide: - to renew the certification. This renewal may be accompanied by comments or corrective action requests; - to renew the certification with notice to correct the nonconformities identified within a given period, with or without additional inspections; - to suspend or withdraw the certification; or - to perform additional inspections or checks before making a decision. If a decision to renew certification has been made, EUROVENT CERTITA CERTIFICATION notifies the holder of the renewal of the right to use the NF mark. If certification is suspended or withdrawn, EUROVENT CERTITA CERTIFICATION notifies the holder of the suspension or withdrawal of the right to use the NF mark, giving the reasons for the decision. Sanctions may be proposed by the Programme Committee, if necessary. The sanction shall come into effect on the date of receipt of notification thereof. The charges of additional verification caused by the sanctions shall be borne by the holder. Holders are responsible for their use of the NF mark relating to the product concerned and agree to implement the measures arising from the suspension or withdrawal of the usage right, made in accordance with the certification reference standard (as defined in 1.1). If the right to use the NF mark is suspended or withdrawn, the holder is prohibited from using the NF mark and making reference to the mark on any new products manufactured (see 3.4). For products manufactured prior to the suspension or withdrawal of the usage right, EUROVENT CERTITA CERTIFICATION may take specific measures on a case-by-case basis. The holder may challenge the decision by submitting an appeal in accordance with the General Rules of the NF mark. Statement of changes Any changes to the initial conditions of obtaining the NF mark shall be reported in writing by the holder within one month. If EUROVENT CERTITA CERTIFICATION observes that this obligation has not been honoured, the right to use the NF mark may be suspended or withdrawn. For all other cases not covered in paragraphs to 3.3.7, EUROVENT CERTITA CERTIFICATION determines whether the changes call the certification into question and whether an additional inspection is necessary Changes concerning the holder The holder shall notify EUROVENT CERTITA CERTIFICATION in writing of any legal changes to the company or any change in the corporate name. In case of merger, bankruptcy or takeover of the holder, all of the holder's rights to use the NF mark cease automatically. EUROVENT CERTITA CERTIFICATION is responsible, after consulting the Programme Committee if necessary, for examining the terms of any new application for admission that might be made.

26 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 26 of Changes concerning production entities Any transfer (total or partial) of the production entity(ies) of an NF-certified product to a different production site brings about an immediate cessation of NF marking by the holder on the transferred products in any form whatsoever. The holder shall inform EUROVENT CERTITA CERTIFICATION in writing of the new production procedures envisaged. Based on the information sent by the holder, EUROVENT CERTITA CERTIFICATION will identify any checks to be performed on a case-by-case basis. These checks may include an audit of the new production site, limited or comprehensive testing and, if applicable, presentation to the Programme Committee. The certification renewal evaluation and decision procedures are identical to those for admission described in paragraph Changes concerning the quality organisation of the manufacturing and/or marketing process The holder shall declare in writing to EUROVENT CERTITA CERTIFICATION any change regarding its quality organisation likely to have an impact on the compliance of the manufacturing and/or marketing with the requirements of the technical certification rules (changes to its facilities, quality plans, agent, etc.). Furthermore, any temporary cessation of the internal inspection of an NF-certified product results in immediate cessation of the NF marking thereof by the holder in any form whatsoever. The holder shall inform EUROVENT CERTITA CERTIFICATION. In this case, the procedure set out in applies. The certification renewal evaluation and decision procedures are identical to those for admission described in paragraph 3.1. Where appropriate, if a third party is tasked with distribution, the holder undertakes to immediately inform EUROVENT CERTITA CERTIFICATION of any changes to the distribution of its products, and in particular any interruption in supply by the designated third party Changes to the scope of certification: additional admission for a new model and/or new range An additional admission application for the right to use the NF mark must be made for a new model and/or a new range, in accordance with the provisions set out in each technical certification rules Following examination of the application and the corresponding file, EUROVENT CERTITA CERTIFICATION determines which, if any, verifications (which may include an audit) and tests are to be conducted and informs the applicant of either acceptance of the file "as is", the performance of preliminary inspections or referral to the Programme Committee if necessary. The samples required for carrying out tests are sent by the applicant under its responsibility, to the independent laboratory charged with carrying out the tests. The certification evaluation and decision procedures are identical to those for admission described in paragraph 3.1.

27 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 27 of Changes concerning the NF-certified product: Extension EUROVENT CERTITA CERTIFICATION shall receive a written statement of all changes, whether or not they affect the compliance of a certified model and/or range with the requirements set out in each technical certification rules, by means of an extension application for the right to use the NF mark in accordance with the provisions set out in each technical reference standard. Following examination of the application and the corresponding file, EUROVENT CERTITA CERTIFICATION determines which, if any, verifications and tests are to be conducted and informs the applicant of either acceptance of the file "as is", the performance of preliminary inspections or referral to the Programme Committee if necessary. The samples required for carrying out tests are sent by the applicant under its responsibility, to the independent laboratory charged with carrying out the tests. The certification evaluation and decision procedures are identical to those for admission described in paragraph Application for Brand name The right to use the NF Mark granted to a product under a given designation or trade mark is not automatically extended to similar products from the same source, sold under a different designation or trade mark. A holder of the NF mark that wishes to market a certified product under a new designation or trade mark shall apply to maintain the right to use the NF mark using the form set out in each technical certification rules. If the product is marketed by another company, the application shall be countersigned by said company (and the agent if applicable) Temporary or permanent cessation of production of an NF-certified product The holder shall inform EUROVENT CERTITA CERTIFICATION immediately of any temporary cessation of production or inspection of a certified product. Having consulted the Programme Committee if necessary, EUROVENT CERTITA CERTIFICATION may notify the holder that the right to use the NF mark has been suspended for the products in question, together with the procedure for lifting the suspension. The maximum suspension period is one year (unless otherwise specified in the relevant technical reference standard). After this period, the right of use is withdrawn. The holder shall inform EUROVENT CERTITA CERTIFICATION if production resumes. If the holder permanently ceases production of a certified product or if he waives the right to use the NF mark, he must inform EUROVENT CERTITA CERTIFICATION, indicating the period he considers necessary for depletion of the remaining stock of products bearing the NF mark. EUROVENT CERTITA CERTIFICATION sets out the conditions under which the stock can be depleted, after consulting the Programme Committee if necessary. Notification of withdrawal of the right to use the NF mark is given on expiry of the stock depletion period approved by EUROVENT CERTITA CERTIFICATION.

28 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 28 of 31 Conditions for stopping marking or removal of the mark in the event of suspension, withdrawal or waiver The mark shall be removed when notification of the suspension or withdrawal of the right to use the mark is received. All use of the NF mark is prohibited when notification of the sanction decision is received. The mark shall be removed in such a way that there is no ambiguity. The holder shall completely remove or conceal the mark logo, or any reference to the mark, from all media (see 2.4.2). If necessary, the media shall be destroyed. EUROVENT CERTITA CERTIFICATION may check, by any convenient means, that the mark has been removed satisfactorily. If the holder who has lost the right to use the NF mark fails to remove the mark completely, it is liable to legal proceedings for fraud and/or misleading advertising.

29 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 29 of 31 Part 4 - FINANCIAL PROVISIONS This part defines the cost of the services pertaining to NF certification and describes the collection procedure. Fees for the services involved in obtaining certification and monitoring certified products are indicated in a list of charges which may be revised annually. The list of charges for the current year is sent to all mark applicants/holders on request from EUROVENT CERTITA CERTIFICATION and can be viewed at The prices are expressed in Euro, and are exclusive of tax. 4 Cost of certification Obtaining certification The application fee is intended to cover the costs incurred in producing and updating the various documents necessary for the running of the certification programme in question. It is charged per programme once only to each new applicant. The examination services for each factory include the examination of files, the audit, and simulation or testing on the samples taken Follow-up of certified products Invoicing covers the right to use the NF mark, passed on to AFNOR Certification, application follow-up, the audit and tests carried out on any samples taken, and publication of data Annual fee for the right to use the NF mark When the admission file is opened and following product certification, EUROVENT CERTITA CERTIFICATION invoices the holder for an annual fee for the right to use the NF mark; this is paid to AFNOR Certification. This usage fee is included in the list of charges for each programme. This usage fee is intended to cover: - general operation of the NF mark (quality system, monitoring of bodies in the NF network, management of the NF mark committee, etc.); - protection of the NF mark: filing and protection of the mark, legal counsel, processing of improper uses (legal services, etc.); and - contribution to the general promotion of the NF mark.

30 Certification Manual for NF programmes managed by Eurovent Certita Certification: General provisions - Rev0 Page 30 of 31 Terms of payment Collection of payment EUROVENT CERTITA CERTIFICATION, as a mandated body, is authorised to collect payment of all invoices and pays the appropriate portion to AFNOR Certification. The applicant or holder shall pay for all of these services under the conditions set. Any failure on its part impedes EUROVENT CERTITA CERTIFICATION in the exercise of its inspection and intervention responsibilities pursuant to this technical certification rules. If the first enforcement order, sent by registered letter with acknowledgement of receipt, does not result in payment of the total amount due within one (1) month, EUROVENT CERTITA CERTIFICATION may take protective measures with regard to the right to use the NF Mark, for all of the holder's certified products Administrative costs The fee for examination of the application is paid as a single sum when the application is filed and covers its examination (for a production site), its presentation to the Programme Committee, a contribution to the general operation of the mark and a fee for the right to use the NF mark paid to AFNOR Certification. The costs are charged at the minimum rate, and additional fees may be charged on the basis of EUROVENT CERTITA CERTIFICATION's hourly rate, in case of review or additional technical assistance necessary to process an application. The amounts relating to all of the certification services are non-refundable, regardless of the result of the evaluation and whether or not the right to use the NF mark is granted. If acceptance is granted during the course of the year, the amounts invoiced correspond to the services provided. The costs relating to monitoring the certified products are non-refundable in the event of non-renewal, waiver, suspension or withdrawal of the right of use during the year. All applications to waive the right to use the NF mark shall reach EUROVENT CERTITA CERTIFICATION by 30 November of the current year, so that the model or range is not taken into account for the following year. As long as the holder has stocks of products bearing the NF mark, inspections are continued and the corresponding fees are due Audits A flat rate for travel time is included in the cost of the audit, in accordance with the following geographical breakdown: Zone 1 Mainland France, Benelux, Germany, Switzerland, Liechtenstein, Italy, Spain, Portugal Zone 2 Zone 3 EU countries not listed in zone 1, Turkey, Norway, Iceland, Morocco, Tunisia, Algeria French overseas departments and territories and countries not listed in zones 1 or 2

31 Certification body mandated by AFNOR Certification 48/50 rue de la Victoire PARIS Telephone : +33 (0) / CERTIFICATION RULES OF THE MARK RADIATORS, CONVECTORS AND CEILING-MOUNTED RADIANT PANELS, HOT WATER HEATING, FAN ASSISTED AND MIXED Identification number of AFNOR Certification: NF- 047 Revision number: 14 (this version cancel and replace all previous version) Approbation by AFNOR Certification: 12/12/2016 Date of the first edition of application: 03/02/1982 Reference document: GENERAL RULES OF THE NF MARK Approved by the president of AFNOR on 23 April 2012.

32 Certification Rules NF 047 Page 2 of 63 CONTENTS PART 1: PRESENTATION AND SCOPE Scope Who can apply for the NF mark and why? The NF mark... PART 2: THE REQUIREMENTS OF THE RULES Applicable documents The standards and additional specifications The regulations Quality management requirements Marking... PART 3: HOW TO OBTAIN CERTIFICATION: the admission procedures Filing an application for certification Examination of the application / admissibility Verification procedures Evaluation and decision... PART 4: MAINTAINING THE CERTIFICATION: the control procedures Monitoring procedures Evaluation and decision Modifications statement... PART 5: PARTICIPANTS... PART 6: USE OF THE APPLICANT'S/HOLDER'S LABORATORIES If the applicant's/holder's laboratories are not accredited If the applicant's/holder's laboratories are accredited... PART 7: RATES... PART 8: CERTIFICATION APPLICATIONS... PART 9: ADDITIONAL SPECIFICATIONS... APPENDIX 9-A: specific requirements for radiators and convectors with hot water heating... APPENDIX 9-B: specific requirements for ceiling-mounted radiant panels with hot water heating... APPENDIX 9-C: specific requirements for fan-assisted radiators and convectors... APPENDIX 9-D: specific requirements for mixed radiators...

33 Certification Rules NF 047 Page 3 of 63 Part 7 Part 9 Specific requirements Specific requirements by covered types of products Part 8 How to complete applications? Standard letters and applications What are the costs? - applicable rates - terms of payment Contents Update and History of modifications APPLICANT HOLDER Part 1 Which products are covered by the NF mark? - scope - who can apply for the NF mark and why? - the NF mark Part 2 What requirements have to be satisfied? - for the product - for the quality management system - for marking Part 6 Used of manufacturer lab s Arrangement for the delivery authorisation Part 3 How is certification obtained? - application file - acceptance audit - acceptance process Part 5 Which bodies are involved? - AFNOR Certification - Mandated body - auditors - test laboratories - special committee Part 4 After certification - monitoring - changes and modifications

34 Certification Rules NF 047 Page 4 of 63 These certification rules were submitted to AFNOR Certification for approval and admission into the NF certification system. It was approved by the General Manager of AFNOR Certification on 12 December It cancels and replaces any previous versions. EUROVENT CERTITA Certification, as a certifying body accredited by COFRAC under the number n the scope of the accreditation can be found on - agrees to draw up a certification rules that meet the expectations of the market in terms of the certification process and the definition of the requirements. Therefore, the certification rules can be revised, in part or in full, by EUROVENT CERTITA Certification after referring to the interested parties. The revision is approved by the General Manager of AFNOR Certification for admission to the NF certification system. First date of application of the rules: 03/02/1982 MODIFICATIONS Part modified Revision N Date All 14 12/12/2016 Modification performed NF047 : - Update of the requirements of product s quality - Commitment of the applicant - Update of the documents related to the application of the certification - Various corrections Pat 9 Appendix A - Take into account the revision of the standard EN 442 and update of the requirements of the product s quality - Various corrections Part 9 appendix B - Take into account the issue of the standard EN Pat 9 appendix D - Update of the 9D-4.3. Abnormal functioning condition - Various corrections - Modification of the tittle NF047 Rules. - Update of the Company Name CERTITA by EUROVENT CERTITA All 13 29/10/2014 Certification. - NF logo: correction on declension. - Take into account the new requirements of the standard ISO 17065; - Various corrections. - Adaptation of the rules to the new general rules of the NF mark (rev. All 12 23/05/2013 6) and new guide to writing the certification rules (reference) of the applications of the NF mark, - Extension of the rules to include:. radiators and convectors with fans,. mixed radiators. All 11 18/04/2011 Replacement of ATITA (technical secretariat) with CERTITA (mandated).

35 Certification Rules NF 047 Page 5 of 63 Part 1 PRESENTATION AND SCOPE 1.1 Scope These certification rules NF047 concerns the appliances fed with hot water or steam at temperatures below 120 C. On this day, these rules apply to the following products: - Radiators fed with hot water, - Wall-mounted convectors fed with hot water, - Radiators or convectors with fans-assisted, - Mixed radiators, - Ceiling-mounted radiant panels fed with hot water. The definition of each product and the certified characteristics can be found in the appendices of part Who can apply for the NF mark and why? These rules are open to any applicant whose products fall within the above-defined scope and meet the technical requirements described in part 2 of this document: - definition of applicants / mandated bodies / distributors: 1 Applicant / holder: A legal entity that provides control and accountability for compliance with all requirements specified in the NF 047 mark standard. These requirements cover at least the following steps: design, fabrication, assembly, quality control, marking, packaging and introduction onto the market, and specify the critical points of each step. Any legal entity can claim the right to use the NF mark, if it meets at least one of the following three conditions: *intellectual ownership of the product, *fabrication (includes fabrication/assembly, quality control, marking and packaging), *distribution of the products. Any contractual ties between the applicant / holder and the service provider, to whom one of the requirements is subcontracted, must be defined in the form of a subcontracting contract between the two parties, as defined in part 8. In particular, this contract must specify the service provider's commitment to meet the applicable requirements of these rules.

36 Certification Rules NF 047 Page 6 of 63 2 Mandated body: Legal entity or private individual located in the EEA which has a representative function of the applicant/holder outside the EEA and has a contractual and written power of attorney from the applicant/holder stating that it can act on its behalf and specifying in what framework (missions and associated responsibilities and financial aspects, claims, certifying body contact, among others) in the NF mark certification process in accordance with the provisions of the certification rules. The mandated body may be the distributor or the importer; its various functions are clearly identified. 3 Distributor: Legal entity distributing the products of the applicant/holder that does not modify the product with regard to NF mark requirements. The types of distributors can be the following: - distributors who do not intervene technically on the product and distribute the product under the holder's trademark, distributors who have no technical intervention on the product and distribute the product with a change of trademark. In this case, it is necessary to maintain the right to use or to apply for the right to use, if the applicant does not wish that explicit reference to the applicant/holder be made. In the latter case, the respective responsibilities are defined by contract and the agreement of the applicant/holder must be in writing, distributors who intervene technically on the product must apply for the right to use and are considered as applicants in their own right. 1.3 The NF mark Created in 1938, the NF mark is a registered collective certification mark that certifies the conformity of products with the applicable national, European and international standards, which may be completed by additional specifications, under the conditions defined in the certification rules. The mark is awarded by AFNOR Certification and its network of partners, which form the NF network. The NF mark is a voluntary product certification mark that meets the requirements of the French Consumer Code, in particular by involving the interested parties in the validation of the certification rule, by defining the rules applying to product markings and by communicating clearly and transparently on the main certified characteristics. The right to use the NF mark is granted on the basis of compliance with one or more standards and more generally with the entire rules, for a product coming from an applicant and a designated design and/or manufacturing and/or marketing process. Awarding the right to use shall under no circumstances substitute the legal responsibility of the company holding the right to use the NF mark by the responsibility of EUROVENT CERTITA Certification. The NF mark checks the characteristics for the protection of the safety of persons and property, suitability for use and the durability of products, and any other additional characteristics that differentiate the product on the market.

37 Certification Rules NF 047 Page 7 of 63 Unanimously recognised by economic players, consumers, public authorities and institutions, the NF mark has acquired an indisputable reputation that has been rewarded by the very status as a "very well renowned mark" in France. This renown is based on: compliance with standards, a symbol of the consensus reached between the interested parties, the guarantee of quality, safe and high-performance products that have been tested and checked, the will to meet the changing needs of the markets, confidence in the robustness of the certification process resulting in the award of the mark (thoroughness, transparency and impartiality, command of the processes), confidence in the competence and impartiality of the bodies that award the mark. The operation of the NF mark relies on a network of mandated certifying bodies, technical secretariats, laboratories, inspection bodies, auditors and recognised regional technical experts that, along with AFNOR Certification, make up the NF Network. In accordance with the General Rules of the NF mark, AFNOR Certification has appointed EUROVENT CERTITA Certification, the certifying body, to manage the mark NF-047. EUROVENT CERTITA Certification is answerable to AFNOR Certification for the operations with which it is entrusted and which are covered by a contract with AFNOR Certification. 1.4 Contacts list Who to contact? EUROVENT CERTITA CERTIFICATION 48/50 rue de la Victoire PARIS / certita@certita.fr Contacts: Project Manager: Mr Pascal BUTIN p.butin@certita.fr Assistante : Mrs Gloria COSTA g.costa@certita.fr

38 Certification Rules NF 047 Page 8 of 63 Part 2 THE REQUIREMENTS OF THE RULES 2.1 Applicable documents The rules of this application of the NF mark, under the terms of the French Consumer Code, are made up of: the General Rules for the NF mark setting out the general organisation and terms of use of the mark, this certification rules, which describes the technical characteristics to be respected, and the procedures used to check the conformity of these characteristics, the standards to which these certification rules refers, and the additional technical specifications. These certification rules are used to certify products and services, other than foodstuffs specified in the French Consumer Code 1, which specify the conditions of application of the General Rules of the NF mark to the products defined in part The standards and additional specifications The standards for each product type or specific tests methods are given in part 9. The lists of the standards written in these Rules take into account the main standards but they are not exhaustive. Standards: NF EN ISO 9001: Quality management systems Requirements, NF EN ISO/IEC 17025: General requirements for the competence of testing and calibration laboratories. NF EN ISO 2409: 2013 Paints and varnishes - Cross-cut test. NF EN ISO 19011: 2012 Guidelines for auditing management systems. EN ISO 9227 : Corrosion tests in artificial atmospheres -- Salt spray tests Additional specifications The additional specifications for each type of product covered by the applicability of the present rules are given in part The regulations The products covered by these certification rules must comply with the regulations in force. They have to be manufactured so as to comply with all of the directives and regulations in force that are applicable to them. 1 Articles R et R of the French Consumer Code on the 26/10/2016.

39 Certification Rules NF 047 Page 9 of Requirements for quality management Purpose The applicant/holder and their distributors are each responsible, as far as they are concerned, for the right to use the NF mark for the product being considered. The applicant/holder shall take every step necessary to guarantee the compliance of the product with these certification rules on an ongoing basis. This paragraph defines the minimum provisions that the manufacturer shall set up in terms of quality management so that the products covered by the NF mark are produced at all times in accordance with this certification rules. The requirements specific to the products are also defined in part 9. Paragraph 2.4 constitutes the audit standard. The quality system is partly based on the manufacturer setting up a series of organisational provisions to control the compliance of the products delivered with standards and additional specifications, where applicable. These provisions are described in paragraphs and These provisions can be completed by specific requirements related to the type of product certified. In this case, they are given in part 9 of the present certification rules Minimum requirements for quality management Chapter Title 4 Quality management system 4.2 Documentation requirements General Quality Manual Document control Control of records 5 Management responsibility 5.3 Quality policy Quality goals 5.6 Management review General Input of the review Output of the review

40 Certification Rules NF 047 Page 10 of 63 Chapter Title 6 Resource management 6.2 Human resources General Competence, awareness and training 7.4 Purchasing Purchasing process Information on purchasing Checks of purchased products 7.5 Production and preparation of service Control of service preparation and production Identification and traceability Product preservation 7.6 Control of monitoring ad measuring equipment 8 Measurements, analysis and improvement 8.2 Monitoring and measurement Customer satisfaction Internal audit Product monitoring and measurement 8.3 Control of non-conforming product 8.5 Improvement Corrective action Preventive action Audits may be reduced for companies with a certified quality management system complying with the standard NF EN ISO 9001, under the condition that: - Includes, within its scope and perimeter, sites and activities covered by the NF mark, - Has been issued by an authorised certification body by COFRAC or an EA member (European cooperation for Accreditation) see members on the COFRAC website ( lightening can be apply when the ISO certificate is sent to EUROVENT CERTITA CERTIFICATION; Minimum requirements specific to the products General The manufacturer must have the necessary resources and means during the inspections and tests to guarantee product conformity.

41 Certification Rules NF 047 Page 11 of 63 The manufacturer must set up a documented inspection plan that must, as a minimum, include the inspections and tests described in the following paragraphs and the complementary requirements defined in part 9. The frequency of the sampling is determined at the manufacturer's initiative and must be representative of the quantity of products manufactured. If the inspection frequencies are specified (hereafter or in part 9 relating to the products), then they must be taken into consideration in the manufacturer's inspection plan. However, the manufacturer is free to define stricter frequencies. The inspection results must be recorded in registers or other documents kept for this purpose and retained in accordance with a documented procedure. The tolerances applying to the dimensional inspections of the product shall be shown on the manufacturer's drawings and/or the inspection instructions. These tolerances shall not exceed the tolerances specified in the standard applicable to the product in question or specified on part Acceptance inspection of the components and raw materials The requirements applying to the acceptance inspections of each product type are included in part Inspections during production The requirements applying to the acceptance inspections of each product type are included in part Leak and pressure resistance tests The tests described below are applicable to all the products covered by this application, apart from mixed radiators. The leak test requirements for mixed radiators are defined in part 9, appendix D. - Leak tests: The manufacturer must perform a leak test on each individual products by subjecting them to a pressure at least 1.3 times the maximum pressure declared by the applicant/holder. The test pressure must not be lower than 5.2 bar. A pressure gauge, having at least an accuracy of ±5%, must be installed on each test bench that is readily visible to the operator during the test operations. The test can be made with water or air under pressure:. For test using water, the pressure has to be maintained during 10 seconds into the product, after stabilisation of the pressure.. For test using air, the pressure has to be maintained during 3 seconds into the product, after stabilisation of the pressure. - Pressure resistance tests: Once a week and on each production line, the manufacturer must take an product measuring at least 500 mm in length and subject it at least to a test pressure 1.69 times the maximum operative pressure declared by the applicant/holder. The product is compliant if it does not leak. The test can be made using water or air. The pressure has to be maintained into the product during 2 minutes and checked by a pressure gauge having at least an accuracy of ±5%.

42 Certification Rules NF 047 Page 12 of 63 In the case of design or towel radiators produced with steel tubes, the frequency of check can be reduced as followed: Level 1: once a week and per production line.. After 6 conforming consecutive tests go through the level 2. Level 2: Once per two months and per production line. After 3 conforming consecutive tests go through the level 3. Level 3: once per each 6 months and per production line. From the first result observed non-conforming, the level 1 has to be applied immediately Paint inspections The methods used for the preliminary treatment and paint (or any other finish, such as chrome, polishing, etc.) must cover all of the exterior surfaces of a protective coating in touch with the air. - Painting process: At least once a week, the manufacturer must perform periodical inspections all along the painting process, from the surface treatment of the products to the paint curing oven. The gradient of temperature of each oven of polymerization must be monitored at least once a year to guarantee a good quality of cooking of the final paint. The records have to be kept. - Thickness of the painting on the product: The manufacturer shall once a day and per painting line verified at least the finish coating thickness. The level of acceptance criteria must be documented. For the products covered by the standard NF EN (see the edition of the standard in 2.2 of this rules), the requirement of reaction to fire must be respected. - Cross-cut test: On painted products that are ready to be installed, the resistance of the paint to separation must be tested according to the standard NF EN ISO If the result is in the classification 0 or 1, as defined in table 1 of this standard, then paint is compliant. Inspections must be made at least once a day. - Corrosion test in salt spray atmosphere: Once a year tests are performed on one product selected after the process of the paint. For all products covered by the scope of these Rules, excepted for the cast iron radiators painted only with priming coat against the corrosion, a corrosion test in salt spray atmosphere has to be performed in accordance with the standard ISO 9227 (see the edition of the standard in 2.2). After 200 hours of test, the conformity is reached if there is not on the surface of the appliance, without stripe on the appliance for the necessity of test, damage on the coating surface such as, flakes, blisters, cracks, superficial rust points. Corrosion and detachment test of the coating on the appliance, with stripes realized in accordance with the standard ISO 9227 (see the edition of the standard in 2.2 of this rules), shall be made until 350 hours and beyond if the manufacturer wishes it. A measure has to be made at least at 200, 250, 300 and 350 hours. The evaluation of the results are made in accordance with the technical specifications of the manufacturer.

43 Certification Rules NF 047 Page 13 of 63 The test in wet atmosphere is allowed until 30/06/2017, excepted in the case where the manufacturer changes the surface treatment process of the appliances and/or of the painting Inspection of the NF mark on the products The manufacturer must inspect the NF mark, (as define ), in order to make sure that they are legible just after the painting process and that only certified products are marked. These inspections must be made at least once a day Document control In order to guarantee that the data is compliant and that the requirements applying to the documentation defined in paragraph and in part 9 are met, all the manufacturer's documents (in hardcopy or electronic format) mentioning the certified characteristics must be checked by competent persons before they are released. The holder shall also ensure that it controls its applications for the right to use the NF mark, in order to inform EUROVENT CERTITA Certification of any modification of elements forming them, particularly if they affect the certified features (for example: thermal outputs, gradients, maximum working pressure, etc.) Inspections on the finished product In the product audits, the manufacturer must periodically inspect samples (at least once per month) to check that the products are compliant. Inspections must be made of: - The conformity of the stacking of the products according to the documented instruction; - the check of the storage condition to guarantee the integrity of the products - the conformity of the markings with the product, - conformity of the products with the labelling requirements, according to the standard applicable to the product. If the maximum working pressure and/or thermal output and/or the characteristic equation are indicated, the conformity of these indications must be checked, - presence and legibility of the NF mark, - presence of any visual faults in the paint Processing of complaints The manufacturer must take actions to manage complaints by customers about the certified products. The processing of complaints and any subsequent actions must be recorded and preserved.

44 Certification Rules NF 047 Page 14 of Marking Marking is an integral part of the certification of a product. Beyond the identification of a certified product and its traceability, the marking of a product with the NF logo ensures better protection of the users and facilitates the defence of holders against misuse and fraudulent imitations. The reproduction and display of the AFNOR, AFNOR Certification and EUROVENT CERTITA Certification logos is strictly forbidden without the prior approval of these bodies Reference texts The French consumer code Article R433-2 (decree on 29/06/2016) of the French Consumer Code (on 26/10/2016) stipulates that: "When reference is made to certification in advertising, on labelling or the presentation of any product or service, and in commercial documents of any kind relating thereto, the following mandatory information are provided to the consumer or user: the designation or company name of the certifying body or the collective certification mark, The name of the certification referential used, The manner in which the certification rules can be consulted or obtained." Moreover, the purpose of indicating the main certified characteristics is to make the technical characteristics to which the NF mark applies more transparent for consumers and users. It adds value to the certification and its content. A certified characteristic is any technical characteristic whose content is checked within the scope of the NF mark. For the purposes of these certification rules, the certified characteristics are defined in the appendices of part 9. General Rules of the NF Mark The purpose of the marking rules given below is to guide the holder in complying with the regulation requirements and the NF certification requirements. The general rules of the NF mark specify the conditions of use, of validity and the penalties in the event of improper use of the NF mark. Without prejudice to the sanctions laid down in the general rules of the NF mark, any incorrect announcement of the certified features and any fraudulent use of the NF logo expose the holder to lawsuits for fraud and/or misleading advertising. Information related to the certified products are available on the website or They cover notably: - Product identification; - NF047 Rules; - Holder identification; - Certified characteristics;

45 Certification Rules NF 047 Page 15 of 63 EUROVENT CERTITA Certification provides, on request, information regarding the validity of a given certification. When the holder provides copies of certification documents, it has to be reproduce integrally The NF logo The NF logo shall assure the identification of all certified products. The holder commits to respect the style guide of the NF mark. The NF logo and the style guide can be obtained from EUROVENT CERTITA Certification (see contact details on the cover page). The NF certified product must bear a designation and identification distinct from non-nf certified products. The holder must only use the NF logo to distinguish certified products, without risk of any possible confusion with other products, particularly with non-nf certified products. Holders are advised to submit all documents (hardcopy and electronic) containing the NF mark to EUROVENT CERTITA Certification in advance, in order to avoid any risk of misinterpretation and errors that could require the holder to correct its documentation and withdraw any incorrect documents from circulation Marking process This paragraph describes both the process for affixing the NF logo and the marking of essential certified characteristics. In order to meet the requirements of article R433-2 (decree on 29/06/2016) of the French Consumer Code (on 26/10/2016), the mark must be produced as follows, whenever this is technically possible: - For the radiators fed only hot water heating:

46 Certification Rules NF 047 Page 16 of 63 - For the radiators and convectors fan-assisted: - For the radiators mixed: This section covers the following three aspects: 1. marking of the NF logo on the NF certified product 2. marking of the NF logo on the packaging of the NF certified product, if applicable 3. marking of the NF logo on documentation As indicated on 2.5.1, it is recommended to inform the consumer about the main reasons and the advantages to use a certified product Marking of the NF-certified product Each certified product must show the NF mark permanently, visibly, legibly and durably in accordance with the conditions defined in paragraph 2.5.3, and in accordance with the specific standards and the applicable regulations. - For convectors The mark is applied to both the heat exchangers and the housing.

47 Certification Rules NF 047 Page 17 of 63 - For the other products Steel: The markings are preferably placed on welded sleeves or attachments. Cast iron or aluminium: Markings made in the foundry, preferably near a coupling. - Indications to appear on the product The product is marked in accordance with the marking conditions defined in paragraph 2.5.3, along with the holder's identification number, which may be followed by the identification number of the production unit, if the NF mark recognises several sites. The holder receives his identification number with the certification of admission to the right to use the NF mark. - Marking difficulties In case of technical impossibility, the mention relate on the type of product (title under the NF logo) thus this related at EUROVENT CERTITA CERTIFICATION and this on the web site address can be omitted, if these markings are not technically possible. If they are present, then these markings must be clearly legible. The minimum permissible markings are: (*) Holder's identification number. NF 047 / XXX (*) However, due to the specific nature of the NF 047-certified products, the following exceptions to the above-mentioned requirements are permitted: - the requirement for the minimum size of the standard logo defined in the style guide is replaced by the notion of legibility. - moulded or stamped markings will be corrected when a new tool is installed. When the holder experiences difficulties in meeting the above requirements, the planned type of marking is subject to prior approval by EUROVENT CERTITA Certification. The request must explain the reasons and the planned marking project. The following requirements must be met when self-adhesive labels are used: - They must withstand a minimum temperature of 110 C, - The adhesive must withstand the variations in temperature of the product, - The NF logo (as defined in paragraph 2.5.3) must withstand attack by solvents that are regularly used. The holder's application for exception must be accompanied by the label supplier's specifications, including details of the temperature limits. The holder must provide a commitment to meet the second and third requirements.

48 Certification Rules NF 047 Page 18 of Marking on the packaging of the NF certified product or on supporting documentation (including labels) Displaying the NF mark on packaging and/or the documents accompanying the certified products is a means of promoting NF certified products. Therefore, holders of the NF mark are strongly advised to also display the NF mark on the packaging and/or the documents accompanying the certified products. In addition to the NF mark defined in 2.5.3, and at the very least, the reference and trade name of the certified product must also appear on the packaging Marking on documentation (technical and sales documents, labels, posters, advertisements, websites, etc.) Displaying the NF mark on the holder's documentation is a means of promoting these products. Therefore, holders of the NF mark are strongly advised to refer to it. References to the NF mark in the documentation must be made in such a manner that there is no risk of mixing up certified products and other products. The NF mark must be reproduced in the documentation and advertising materials in accordance with the conditions defined in paragraph Reproduction of the NF mark, as defined in 2.5.3, on the holder's letterhead is prohibited, unless the holder has been granted the NF mark for all of its production. In all cases, the holder must request prior approval from EUROVENT CERTITA Certification. Holders are advised to submit all their documents containing the NF mark to EUROVENT CERTITA Certification for prior approval in order to make sure that this paragraph has been correctly interpreted, to avoid any risk of errors and, by the same token, to avoid the immediate recall of any material that has already been released. Specific requirements for the products are described in part 9.

49 Certification Rules NF 047 Page 19 of 63 Part 3 HOW TO OBTAIN CERTIFICATION: the admission procedure APPLICANT PARTICIPANTS SPECIAL COMMITTEE Preparation of the certification application file Examination of the administrative and technical admissibility of the application for certification ( 3.2.2) Factory inspections: - audit - sampling (where appropriate) Tests in the mark's laboratory Corrective actions (if any) Evaluation of factory visit and test reports Presentation to the application Committee (where appropriate) Decision and notification Follow-up process (Part 4)

50 Certification Rules NF 047 Page 20 of 63 Definition - Definition of the applicant (see 1.2), - Definition of the different types of application An application for the right to use the NF mark can be:. an application for certification. a subsequent application for certification. an application for extension. an application for maintenance An application for admission is submitted by an applicant who does not have the right to use the NF Mark in the application concerned. The application corresponds to a range of products resulting from a given design and/or production and/or marketing process, defined by a trade mark and/or referring specifically to the product in question and its technical characteristics. If one or more parts are subcontracted, the subcontractors agree to refrain from marketing the products under their own brand and trade name using the NF mark. A subsequent application for admission differs from the preceding definition inasmuch as it is made by an applicant who already has at least one right to use the NF mark for the application in question. Applications for extension are made by holders for a product range that has been modified or for the addition of model(s) and height(s). Applications for maintenance are made by holders for a range of NF certified products to be marketed under another brand and/or trade name, or, to replace the brand and/or trade name of the certified range, without making any changes to its certified characteristics. Case of an application for admission 3.1 Filing an application for certification Before making the application, the applicant must be sure to meet, at the time of the application, the conditions defined in these Certification Rules, especially those in Part 2, regarding the corresponding range and sites. The applicant/holder is responsible for making sure that the regulations applicable to its product are effectively respected (for example: CE mark). It must undertake to comply with the same conditions during the entire duration of the right to use the NF mark. Applications for the right to use the NF mark are only admissible for series produced products. The applicant/holder has to make sure that his products covered by a right to use the NF mark comply with all the requirements of this NF Rules throughout the duration of the NF mark.

51 Certification Rules NF 047 Page 21 of 63 To support its application, the applicant undertakes, as a minimum, to: - accept and comply with the terms and conditions set out and defined in the certification rules, and in particular: o present for certification products that comply with the regulations in force, o implement any modification made necessary by changes to the certification rules notified by the certification body, o use the certification mark under the conditions set out in the certification rules and for the certified products only, o take action on the basis of decisions made by the certification body in the context of the certification (in particular, to define and implement corrective action following a discrepancy found, or to apply a penalty decision); - comply at all times with the certification requirements defined by the certification rules, including implementing the appropriate changes notified by the certification body; - ensure that the certified product continues to meet the requirements of the certification rules, in particular: o efficiently apply the internal production control system set up to meet the requirements of the certification rules; o perform the inspections for which it is responsible so that the right to use the certification mark may be maintained; - make all necessary arrangements for: o the conduct of evaluation and surveillance (if required), including provision for examining documentation and records, and access to the relevant equipment, location(s), area(s),personnel, and subcontractors of the client in question; o the investigation of complaints; o the participation of observers, if applicable; - make statements and provide information about the certification in accordance with the scope of the certification, in particular: o not submit counterfeit products for certification, o use the trade name of the product submitted only for products certified in accordance with these certification rules; - not use its product certification in such a manner as to bring the certification body into disrepute, or make any statement regarding its product certification that the certification body may consider to be misleading or unauthorized, in particular: o not misuse the certification mark or use it in a manner that does not comply with the certification rules in force, o not use the certification body's logo; - in the event that certification is suspended, withdrawn or terminated, discontinue its use of all means of communication that refer to the certification, take action as required by the certification scheme and take any other required measure; - in the event that a copy of the certification document is supplied to a third party, reproduce it in its entirety or as specified by the certification rules; - when referring to the certification of its products in communication media such as documents, brochures or advertising, comply with the requirements of the certification body and/or the specifications of the certification program and send the certification body, upon its request, all printed advertisements and catalogues that refer to the certification mark; - comply with all of the requirements that may be prescribed in the product certification program relating to the use of conformity marks and on information related to the product;

52 Certification Rules NF 047 Page 22 of 63 - investigate, record and keep a record of all complaints made known to it relating to compliance with the certification requirements and o make these records available to the certification body and auditors when requested, o take all appropriate action with respect to such complaints and any deficiencies found in the products that affect their compliance with the certification requirements, o document the actions taken; - inform the certification body without delay of any changes that may affect its ability to conform with the certification requirements, in particular: o inform the certification body without delay of any modification to the basic file submitted at the time of application for the right to use the NF mark (particularly any modification to the product(s) for which the application was made). o inform the certification body of any definitive or temporary cessation of production covered by the certificate; - ensure, for all the associated personnel of the certification body or its qualified subcontractors, that all of the safety provisions relating to working conditions, sites or equipment comply with the local regulations in force; - pay the certification fees (management, audit and testing, if applicable) in accordance with the price list in force. If the applicant/holder fails to obey these rules, then the review of their application may be interrupted or suspended. In particular, it is strictly forbidden to make any reference to the NF mark before the right to use it has been obtained, or to submit counterfeit products for certification. If the applicant/holder fails to obey these rules, then the examination of their application may be interrupted or suspended. In particular, it is strictly forbidden to make any references to the NF mark before obtaining the right to use it, or to submit counterfeit products for certification. The application must be submitted in accordance with the conditions and models in part 8. If the product range comes from a manufacturing unit outside the European Economic Area, the applicant will appoint a mandated body within the EEE who jointly signs the application. Upon receipt of the application, the following process is initiated: - Examination / admissibility of the application, - Implementation of checks and inspections, - Assessment and decision. 3.2 Examination of the application / Admissibility Upon receiving the application, EUROVENT CERTITA Certification checks that: - all the required documents are enclosed with the application, - the documents in the technical file meet the requirements of these certification rules. The application is only admissible if: - the applicant controls and takes responsibility for the following steps: design, fabrication, assembly, quality control, marking, packaging; - any steps not performed by the applicant are covered by a contract defining the respective responsibilities with their service provider. The list of the minimum requirements to be included in a contract can be found in the model in part 8. The applicant remains responsible for all the operations and their coherency;

53 Certification Rules NF 047 Page 23 of 63 - the products covered by the application meet the rules and technical specifications laid down in part 2 of these certification rules; - the inspections and tests of the products covered by the application, as specified in the technical documents of these certification rules, are in place; - all the required documents are enclosed with the application, and in particular the contractual documents between the applicant/mandated body and the applicant/distributor, where appropriate. EUROVENT CERTITA Certification also makes sure that it is in a position to respond to the application, and may request any additional information required for the admissibility of the application, if it is incomplete. Once the application is admissible, EUROVENT CERTITA Certification organises the inspections, and informs the applicant about organisation methods (auditor, duration of the audit, laboratories, sampled products, etc.). 3.3 Verification procedures The inspections carried out for the NF mark are generally of two different types: - tests on the products, - the audits (design and/or manufacturing and/or marketing process, distribution centre ), Tests All the examinations and tests of conformity with standards and additional specifications are defined in paragraph 2.2. The examinations and tests are performed under the following conditions: - option 1: by one of the NF mark's laboratories designated in paragraph 5.4 of these certification rules e standard or by one of the laboratories recognised under the "RADMAC" agreement (mutual recognition of test results) or by a laboratory accredited according to the terms of the Construction products regulation n 305/2011 for all applications for admission/extension. - option 2: by the applicant/holder in its "NF authorised" laboratory. The procedure for obtaining this authorisation is defined in part 6. - option 3: by a combination of the above options 1 and 2. - option 4: for electrical safety tests according to the terms of the standard NF EN (30 or 43 or 80) (see the edition of the standard in 2.2), by a laboratory accredited in accordance with the standard NF EN ISO/IEC (see the edition of the standard in 2.2) by an accreditation body that has signed the recognition agreements as part of the EA (European cooperation for Accreditation). The examinations and tests of conformity with additional specifications must be performed by one of the NF mark's laboratories defined in paragraph 5.4 or by one of the laboratories recognised in the "RADMAC" agreement (mutual recognition of test results). The products to be tested are defined in part 9, depending on the products covered by the application for certification.

54 Certification Rules NF 047 Page 24 of 63 The applicant usually directly approaches one of the NF mark's laboratories (as designated in part 5) or one of the laboratories recognised under the "RADMAC" agreement, with a view to proceeding with the product tests in accordance with the applicable standard and, where appropriate, with the additional specifications described in part 9, appendix A 4.2. The applicant/holder can also contact a laboratory accredited under the terms of the Construction products regulation n 305/2011. However, if the additional specifications described in part 9 appendix A 4.2 apply to the type of radiator in question, then these tests must be performed by one of the laboratories mentioned in paragraph 5.4. The applicant encloses the test reports and its catalogue (where appropriate) drawn up by the laboratory with its application for the right to use the NF mark. EUROVENT CERTITA Certification examines the test reports and checks the correlation with the application. If necessary, EUROVENT CERTITA Certification can refer the application to the NF-047 special committee. After granting the right to use the NF mark, EUROVENT CERTITA Certification can sample one or more of the holder's products, independently of the products that are covered by the monitoring of NF certified products defined in part 4. The purpose of these inspections is to confirm / check the conformity: - the thermal output (within a tolerance of -4% relative to the certified output), - pressure resistance, - products relative to the application submitted to EUROVENT CERTITA Certification to acquire the right to use the NF mark. Product sampling request The applicant may also ask for products to be sampled by an inspector, with a view to performing tests in one of the laboratories recognised under the "RADMAC" that it has designated at its request. EUROVENT CERTITA Certification determines the products, possibly by referring to one of the NF mark's laboratories for advice. The list of samples is sent to the applicant in readiness for sampling by EUROVENT CERTITA Certification's representative. The applicant must make sure that a set of 10 products for each sample is made available in the store or on the production line on the day when the samples are taken. Where appropriate, the person in charge of the sampling can ask for a product to be made. The samples are marked with a distinctive sign by EUROVENT CERTITA Certification s representative and sent by, and under the applicant's responsibility, to the test laboratory. The two parties jointly complete and sign the sampling sheet. The laboratory or EUROVENT CERTITA Certification draws up the test reports and sends them to the applicant. These reports may, as appropriate, be sent to the applicant before or after the evaluation.

55 Certification Rules NF 047 Page 25 of audits The audit will last least one day. The audit, carried out by an NF auditor or an auditor recognised under the "RADMAC" agreement (mutual recognition of audit reports), has the purpose of ensuring that the measures defined and implemented by the applicant during the design and/or manufacturing and or marketing process meet the corresponding requirements established in part 2 of these certification rules. The audit is conducted according to the general principles laid down in the standard ISO/IEC (see the edition of the standard in 2.2) for quality audits. The scope of the audit and the details of its execution are specified in an audit plan that is sent to the company beforehand. For situations in which the applicant subcontracts a part of their activity, EUROVENT CERTITA Certification reserves the right to send an NF auditor to audit the subcontractor(s) in the same terms established in these rules. The NF auditor must be provided with all the resources necessary (offices, installations, facilities) to perform the assignment, including competent people to carry it out. With the applicant's agreement, the auditors may make a copy of any document they consider necessary. The auditor can request or perform checks of one or more products on the spot. These checks may apply the requirements defined in these certification rules or in the standards applying to the products regarding: dimensions, mechanical resistance to pressure, resistance to pressure, the conformity of the welds, electrical safety tests, etc. Samples may be identified and/or taken during the audit for examinations or tests. They are sent to the test laboratory by, and under the responsibility of, the applicant. The auditor draws up a sampling sheet signed by both parties. At the end of the audit, the auditor realizes a meeting with the representatives of the Company to remind the objective of the audit and explain the conclusions of the audit. The auditor reminds also the process followed during the audit. The audit report is completed and signed by the both parties at the end of the closing meeting. The Company can refuse the conclusion of the document. If the audit report cannot be given at the end of the audit and if applicable, non-conformity(ies) sheet mentioning the conclusions of the audit is signed by the two parties. The complete audit report will be sent to the representative of the Company. An observer, bounded to the respect of confidentiality (this observer is chosen by EUROVENT CERTITA CERTIFICATION by standards and agreements which he has signed), can take part to the audit. The holder is systematically informed by EUROVENT CERTITA CERTIFICATION of the presence of this observer before the audit. EUROVENT CERTITA CERTIFICATION might suggest the applicant the involvement of another observer.

56 Certification Rules NF 047 Page 26 of 63 Other types of applications A subsequent application for certification The requirements defined in paragraph 3.3 shall apply, on the following conditions: The audit can be adapted or combined with a monitoring audit. Applications for extension These applications cover changes to a certified product range (example: thickness of sheet metal, dimensions, etc.), or additional height(s), EUROVENT CERTITA Certification examines the application and assesses the impact of the change made to the certified products. It may refer to one of the mark's laboratories for advice. If appropriate, it may ask for one or more products to be tested before taking a decision. The steps outlined in paragraph 3.1 shall apply. The outputs of the certified range can be preserved for minor changes that do not affect the certified outputs by more than -4%. The audit can be adapted or combined with a monitoring audit. Applications for maintenance No examinations or tests are necessary. The examination of the application is purely administrative. 3.4 Evaluation and decision EUROVENT CERTITA Certification assesses the report(s) intended for the applicant in accordance with the current procedures (transmission after evaluation or handing out of the report on site). The report(s) shall, when required, include a response request within a timeframe set in the report mailing. The applicant must present, for each deviation, the actions taken or to be taken, including the schedule to put them in place. EUROVENT CERTITA Certification analyses the suitability of the response and may request additional inspections to confirm that the corrective actions have been taken (complete or partial audit and/or tests). If necessary, EUROVENT CERTITA Certification may anonymously present all the evaluation results to the Special Committee (see part 5) for opinion.

57 Certification Rules NF 047 Page 27 of 63 Depending on the results of all inspections, EUROVENT CERTITA Certification notifies one of the following decisions: - Certification - Deferral or refusal of the certification If certification has been approved, AFNOR Certification authorises the use of the NF mark, and EUROVENT CERTITA Certification sends the applicant, who is now a mark holder, the NF certificate and/or letter notifying the decision. The granting of the right to use the mark shall not substitute the legal responsibility of the company, holder of the right to use, with that of EUROVENT CERTITA Certification. The methods of communication about certification are set out in part 2.5 of these certification rules. The applicant may object to the decision made by submitting a claim in accordance with the General Rules of the NF Mark.

58 Certification Rules NF 047 Page 28 of 63 Part 4 MAINTAINING THE CERTIFICATION: the control procedures EUROVENT CERTITA Certification conducts a control of the certified products as soon as the right to use the NF mark is granted, according to the flow chart shown below. HOLDER PARTICIPANTS SPECIAL COMMITTEE Factory inspections: - audit - sampling Tests Corrective actions (if any) Evaluation of factory visit and test reports Presentation to the special Committee (where appropriate) Decision and notification During the entire certification, the holder shall: - comply with the requirements defined and the conditions of marking described in part 2, - keep the certification file up to date using the models enclosed in part 8, - systematically inform EUROVENT CERTITA Certification of changes of any characteristics of the certified product, and/or of its organisation likely to have any consequence on the certification.

59 Certification Rules NF 047 Page 29 of 63 Moreover, EUROVENT CERTITA Certification reserves the right to proceed with any inspections (audits, tests, verifications, etc.) that it deems to be necessary further to: - A change to the certified product or the quality organisation of the production entities (production plant, production workshops, subcontractors' plants, etc.), - Complaints, claims, litigation, etc. regarding the use of the NF mark that came to its notice. 4.1 Monitoring procedures The monitoring of NF certified products includes examinations, analyses or tests on product ranges and audits of the design and/or manufacturing and/or marketing process It also includes supervision of the use of the mark and the logo on the products, packaging and all marketing media. The control procedures are based on the decisions made with reference to the previous controls. The following dispensations (if any). After obtaining the NF mark, annual inspections are made in the production unit and on the NF certified products. However, EUROVENT CERTITA Certification can, at the committee's initiative, reduce the frequency of the audits to once every two years, if the minimal requirements specific to the products defined in paragraph are satisfactory, and it the holder does not benefit from the "RADMAC" agreement Tests on the NF certified product All tests and examinations to determine compliance with standards and additional specifications, as required, are conducted in the following conditions: At least one product per product family admitted to the NF mark is inspected once a year. The test samples are defined by EUROVENT CERTITA Certification. The samples are taken on the manufacturer's premises or on the open market and are identified by EUROVENT CERTITA Certification s representative with a distinctive sign. The products are sent by, and under the responsibility of, the applicant to one of the laboratories designated in part 5, unless EUROVENT CERTITA Certification decides that they are to be sent to a laboratory of its own choosing. If necessary, and in particular if the production unit does not undergo a control audit, EUROVENT CERTITA Certification can ask the holder to build and ship (by a given date) the samples, under its own responsibility, to one of the laboratories designated in part 5, unless EUROVENT CERTITA Certification decides that they are to be sent to a laboratory of its own choosing.

60 Certification Rules NF 047 Page 30 of 63 The conformity tests of the NF certified product are performed in accordance with the standards and, where appropriate, with the additional specifications defined in paragraph 2.2. The laboratory sends the test reports to EUROVENT CERTITA Certification. EUROVENT CERTITA Certification examines the test reports to check the conformity of the results with the certified values, within the permitted tolerances. The tolerance applying to the measurement of the thermal output is -4%. The other tolerances are specified in part 9 for the various products. EUROVENT CERTITA Certification sends the reports and the conclusions of the evaluation to the holder. After notification of the results, the holder can ask the laboratory to return its products. However, if the samples are found to be non-compliant, then the holder must first ask for EUROVENT CERTITA Certification's permission. If the holder does not ask for its products to be returned within three months of the issue of the test reports, the laboratory will destroy them. For holders that possess an authorised laboratory, as per the conditions described in part 6, the control tests can be performed in their own laboratory. However, one of the selected products must undergo comparative tests with one of the NF mark's laboratories of the holder's choosing. EUROVENT CERTITA Certification will inform the holder of the conditions of execution. The test reports drawn up by the holder shall be sent to EUROVENT CERTITA Certification no later than 15 days after the tests. Increased monitoring schedule If the checks produce non-compliant results on one product, then the checks are repeated on at least one other identical product, at the holder's cost. As a general rule, the product is tested in the laboratory that performed the initial tests. Nevertheless, EUROVENT CERTITA Certification reserves the right to designate another laboratory. EUROVENT CERTITA Certification's representative takes a sample of the product on the manufacturer's premises or on the open market, and identifies it with a distinctive sign. The representative completes a sampling form and asks the manufacturer to send, under its own responsibility, the sample to the laboratory. If necessary, and in particular if no products are available in the stock or difficulties are encountered in obtaining a sample of the product, EUROVENT CERTITA Certification can ask the holder to build the samples (before a given date) and to send them to the laboratory. The tests and the evaluation of the results are performed under the conditions specified in the preceding paragraph. Notification of the evaluation of the results Two situations are possible: - the results comply with the certified products: EUROVENT CERTITA Certification informs the holder and the certified characteristics are not corrected. - the results show another instance of non-conformity with the certified products: EUROVENT CERTITA Certification informs the holder and suspends the range, pending corrective action by the holder. The holder proceeds with further tests, as specified in paragraph 3.1-commitment. If an instance of non-compliant acoustic power or absorbed power is detected (see additional requirements in part 9), the difference between the mean of the measured values and the mean of the certified values is deducted from all the certified values.

61 Certification Rules NF 047 Page 31 of 63 After notification of the results, the holder can ask the laboratory to return its products. However, if the samples are found to be non-compliant, then the holder must first ask for EUROVENT CERTITA Certification's permission. If the holder does not ask for its products to be returned within three months of the issue of the test reports, the laboratory will destroy them Audit of the design and/or manufacturing and/or marking process The audit will last least one day. This audit is conducted in accordance with the conditions specified in At the end of the audit, the auditor realizes a meeting with the representatives of the Company to remind the objective of the audit and explain the conclusions of the audit. The auditor reminds also the process followed during the audit. The audit report is completed and signed by the both parties at the end of the closing meeting. The Company can refuse the conclusion of the document. If the audit report cannot be given at the end of the audit and if applicable, non-conformity(ies) sheet mentioning the conclusions of the audit is signed by the two parties. The complete audit report will be sent to the representative of the Company. An observer, bounded to the respect of confidentiality (this observer is chosen by EUROVENT CERTITA CERTIFICATION by standards and agreements which he has signed), can take part to the audit. The holder is systematically informed by EUROVENT CERTITA CERTIFICATION of the presence of this observer before the audit. EUROVENT CERTITA CERTIFICATION might suggest the applicant the involvement of another observer. 4.2 Evaluation and decision The evaluation procedures are the same as for admissions, as described in part 3 ( 3.4). Depending on the results of all the checks, EUROVENT CERTITA Certification can decide: a) to maintain the certification, with observations or a request for corrective actions, where appropriate. b) To realize further checks and verifications before take decision, c) to maintain the certification, with a warning and with or without more inspections, d) to suspend the certification. Suspensions last for maximum of one year. After this, withdrawal of certification is pronounced. e) to withdraw the certification.

62 Certification Rules NF 047 Page 32 of 63 If a decision to uphold certification has been made, AFNOR Certification upholds the right to use the NF mark. If a decision to suspend or withdraw certification has been made, AFNOR Certification suspends or withdraws the right to use the NF mark. For sanctions b), c) and d), the fees for additional verifications are charged to the licensee, regardless of their results. The decisions are enforceable as from the date of notification. EUROVENT CERTITA Certification sends written notice of the decision to the holder. The sanction shall come into effect on the date of receipt of its notification. The charges of additional verification caused by the sanctions shall be borne by the holder. Holders are responsible for the right to use the NF mark relative to the product concerned and agree to implement the actions arising from the suspension or withdrawal of the right of use, made in accordance with these certification rules. All suspensions and withdrawal of the right to use the NF mark lead to the interdiction to use the mark and reference to it for all new production. For products manufactured prior to the suspension or withdrawal of the right of use, the certifier may implement special measures on a case by case basis (for example: authorisation to sell off remaining stocks, sell products in stock at a discount, product recall, etc.). The holder may object to the decision made by submitting a claim in accordance with the General Rules of the NF Mark. 4.3 Modifications statement Any modification to the initial conditions of obtaining the NF mark shall be reported in writing by the holder. If EUROVENT CERTITA Certification observes that this obligation has not been honoured, the right to use the NF mark may be suspended or withdrawn. For other cases that are not covered by parts to 4.3.5, EUROVENT CERTITA Certification determines whether the modifications could cast doubt over the certification and whether an additional inspection is necessary. Depending on the examination results, EUROVENT CERTITA Certification s legal representative takes the appropriate decision Modification concerning the holder The holder shall report in writing to EUROVENT CERTITA Certification any legal modification of the company or any change in the company s name.

63 Certification Rules NF 047 Page 33 of 63 In case of merger, bankruptcy or take over of the holder, the right to use the NF mark for all products from which the holder may benefit, cease automatically. A new application may be submitted and its examination reduced depending on the modifications Modification concerning the production entities Any transfer (total or partial) of the manufacturing unit(s) of an NF certified product to a different production site brings about an immediate cessation of NF marking by the holder on the transferred products in any form whatsoever. The holder shall declare this transfer in writing to EUROVENT CERTITA Certification which will organise an audit of the new production site and, as the case may be, have tests carried out. The certification assessment and renewal decision procedures are identical the those for admission described in Part Modification concerning the quality organisation of the design and/or manufacturing and/or marketing process The holder must declare in writing to EUROVENT CERTITA Certification any change regarding its quality organisation likely to have an impact on the compliance of the design and/or manufacturing and/or marketing with regard to the requirements of these certification rules (changes to the systems, quality plans, mandated bodies, etc.). On the other hand, any temporary cease in the internal quality assurance operation for an NF certified product entails an immediate halt in the NF marking of it by the holder. The holder shall inform EUROVENT CERTITA Certification. The certification assessment and renewal decision procedures are identical to those for admission described in Part 3. Where appropriate, if a third party is tasked with distribution, the holder agrees to immediately inform EUROVENT CERTITA Certification of any changes to the distribution of its products, and in particular any stoppage of procurement by the designated third party Modification concerning the NF certified product EUROVENT CERTITA Certification must be informed by written statement of any modification of the NF certified product with respect to the application, the accepted model or conformity of the product with the requirements of these certification rules or any change of trademark. According to the modification declared, EUROVENT CERTITA Certification determines whether it is a certification extension application, a subsequent or a maintenance application.

64 Certification Rules NF 047 Page 34 of Temporary or definitive cessation of production Any definitive or temporary (more than 6 months) cessation of production of an NF certified product range or any abandonment of the right to use the NF mark shall be declared in writing to EUROVENT CERTITA Certification, specifying the period of time required to deplete the inventory of NF marked products. The production unit must be audited before putting an end to the temporary suspension. The certification assessment and renewal decision procedures are identical at those for admission described in Part 3. EUROVENT CERTITA Certification gives notice of the suspension or withdrawal of the right to use the NF mark by registered letter with return receipt.

65 Certification Rules NF 047 Page 35 of 63 Part 5 PARTICIPANTS The bodies involved in the procedure to grant the right to use the NF mark and to monitor the NF certified products are specified below AFNOR CERTIFICATION AFNOR owns the NF mark and has granted AFNOR Certification exclusive licensing rights. AFNOR Certification manages and coordinates the NF certification system, which particularly defines the NF mark governance rules and procedure. The various bodies mandated by AFNOR Certification to fulfil the functions described below shall not subcontract these functions, in part or in full, without the prior and formal approval of AFNOR Certification. In particular, the decisions taken by EUROVENT CERTITA Certification cannot be delegated. 11 rue Francis de Pressensé F La Plaine Saint Denis Cedex Telephone: +33 (0) Fax: +33 (0) MANDATED BODY In accordance with the General Rules of the NF mark, AFNOR Certification has designated the following mandated body to manage the NF Mark - Radiators, Convectors and Ceiling-mounted radiant panels, hot water heating, fan assisted and mixed: 48 / 50 rue de la Victoire F-7009 PARIS Telephone: +33 (0) certita@certita.fr EUROVENT CERTITA Certification is answerable to AFNOR Certification for the operations with which it has been entrusted and which are covered by a contract.

66 Certification Rules NF 047 Page 36 of AUDIT BODY The audit functions of the manufacturing unit, and possibly the sites of marketing, are carried out by the following body, called the audit body: 48 / 50 rue de la Victoire F-7009 PARIS Telephone : +33 (0) certita@certita.fr The auditors are entitled to inspect the applicant s or holder s facilities, in order to perform their mission. Under the terms of the "RADMAC" mutual recognition agreement, audits can be performed by one of the certification bodies that have signed the agreement. 5.4 TEST BODIES/LABORATORIES When the inspections involve product tests, these tests are performed, at EUROVENT CERTITA Certification's request, by one of the following laboratories, which include the mark's laboratories and the laboratories recognised under the terms of the "RADMAC" (RADiators Mutual ACceptance) agreement. Tests: in accordance with the standards NF EN 442 (see the edition of the standard in 2.2), NF EN (see the edition of the standard in 2.2) and the protocols of the tests and specifications defined in part 9, excepted the part 9 appendix D: Centre Technique des Industries Aérauliques et Thermiques Domaine Scientifique de la Doua 25, Avenue des Arts B.P Villeurbanne Cedex - FRANCE Tel.: Fax: cetiat.commercial@cetiat.fr

67 Certification Rules NF 047 Page 37 of 63 Tests: in accordance with the standards NF EN 442 (see the edition of the standard in 2.2) and NF EN (see the edition of the standard in 2.2). For the part 9 appendix D, restricted for the measure of the temperature and the electrical power: POLITECNICO DI MILANO - DIPARTIMENTO DI ENERGETICA Laboratorio Misure Ricerche Termotecniche (M.R.T.) Via Raffaele Lambruschini, 4 (Zona Bovisa) MILANO ITALIE Tel.: Fax: mrt@polimi.it 5.5 RECOGNITION OF TESTS/AUDITS PERFORMED BY OTHER LABORATORIES/AUDIT BODIES The following monitoring tests/audits may also be taken into consideration: - tests/audits performed under the RADMAC (RADiators Mutual Acceptance) agreement on the mutual recognition of tests and audits - tests/audits performed according to the conditions specified in the rules (part 3) 5.6 SPECIAL COMMITTEE The special Committee is a consultative instance. In its capacity of the secretary of the committee, EUROVENT CERTITA Certification has the following missions: organising meetings, presenting summaries of audits and tests, tracking the proposals made by the committee, compiling the minutes. The members of the Mark Committee are selected in order to represent the various interested parties on an equitable basis and to guarantee their relevance. Composition of the special committee - 1 Chairman (to be designated by the Committee members) - 2 Vice-chairmen (one representative of AFNOR Certification and one representative of EUROVENT CERTITA Certification) - Manufacturers (2 to 5 representatives of the mark's holders) - Users, consumers, prescribers (1 to 5 representatives) - Technical bodies (2 to 6 representatives)

68 Certification Rules NF 047 Page 38 of 63 The members of the Mark Committee are designated by EUROVENT CERTITA Certification. Members of the Mark Committee can be represented by a deputy designated under the same conditions. One of the members of the Mark Committee is appointed Chairman under the same conditions. AFNOR Certification sits on the Mark Committee (vice-chairman by rights). The special Committee issues notices of decision and its members are not allowed to receive any compensation for the duties they perform. The term of office for members is 3 years. This term of office is renewable by tacit agreement. Committee members undertake to perform their function in any impartiality and to ensure the confidentiality on the communicated information. EUROVENT CERTITA Certification takes the specific measures necessary to ensure the confidentiality of applicant or holder files presented to the Mark Committee (except in the event of disputes/appeals). The Mark Committee can delegate certain missions to a board or other entity, whose members must be appointed amongst the members of the special committee. The board consists of the NF Mark Committee Chairman, a representative of each college, a EUROVENT CERTITA Certification representative assisted by a submitter as required (representatives of laboratories and qualified auditors). Board meetings are held as required. The board reports on its works to the Mark Committee meetings. Working groups may be formed for certain occasional missions that do not require all the members of the Committee to be summoned. Working groups are made up of members of the Mark Committee. If necessary, experts and/or holders of the right to use the NF mark for this application and/or external personalities may be called on. The Mark Committee decides on its missions. Its duties will generally be limited to the development of projects, proposals or providing further information on a given topic on behalf of the Mark Committee.

69 Certification Rules NF 047 Page 39 of 63 Part 6 USE OF THE APPLICANT'S/HOLDER'S LABORATORIES FOREWORD This part describes the procedure according to which an applicant/holder may be authorised to conduct, in their own laboratories, all or part of the tests required for examining an application for its own products. If the tests are performed partially, then the remaining tests are to be performed in a mark laboratory. When this authorisation is granted, the holder obtains an "NF authorisation" and the laboratory or laboratories in question are said to be "NF authorised". The NF authorisation of a laboratory applies only to this NF mark, and any mention of this authorisation is prohibited APPLICANT/HOLDER LABORATORIES THAT ARE NOT ACCREDITED General The conditions for authorising an applicant's/holder's laboratory and to consider its test results are set forth in the general rules stated below in and, where appropriate, in special rules that complement these general rules and stipulate the application procedures for each category of product subject to a specific standard. The standard applied is these certification rules for the certification procedures and standard NF EN ISO/IEC for the test procedures General rules Authorisation application The applicant/holder sends the application for authorisation to EUROVENT CERTITA Certification. The application must include: - the types of products for which NF authorisation is requested; - the standards covered by this application; - the complete description of equipment and instrumentation at the laboratory's disposal to perform these tests; - The description of the laboratory's quality management system (quality manual, quality plan); - the applicant's commitment to respect the relevant provisions of the application certification rules, including appendices.

70 Certification Rules NF 047 Page 40 of Examination of the NF authorisation application EUROVENT CERTITA Certification designates a group of auditors tasked with checking the quality assurance measures and the equipment of the laboratory, and the use to test systems. This group is made up of a laboratory auditor for the quality assurance aspects and at least one representative of an independent laboratory, who acts as the expert for the tests aspects. During the laboratory audit, the experts: a) collect the drawings and diagrams of the premises, installations and equipment, gather information for which the standards or rules governing special procedures require compliance, monitoring or inspection; b) check that the laboratory has the necessary and sufficient equipment to performance the tests (the standards or rules defining specific procedures for each type of product, the nomenclature and the precise specifications); c) check that the precision of the measuring products meets the standards or obeys the rules of the special procedures and that the precautions required to maintain the quality of the measurements are taken; d) check that the test equipment is in good working order and is regularly calibrated and rated; e) note the name and title of the test official and the branch or department to which he/she belongs within the company; f) check that the quality management system is suited to the certification operations and that it is actually applied. Prior to any NF authorisation, a comparative test is conducted according to the standards applicable to the product and/or the additional specifications defined in paragraph 2.2, between the applicant's/holder's laboratory and one of the mark's laboratories, on the so-called secondary set of three standard radiators belonging to the laboratory applying for authorisation. EUROVENT CERTITA Certification compiles a report containing: - a report of their audit; - a summary of observations and/or any instances of non-conformity on each point a), b), c), d), e) and f) above; - a list of material and equipment assigned by the applicant/holder for admission testing and which meet the specifications of the rules of special procedures or the standards; - any observations or comments that they deem appropriate. The mark's laboratory, selected by the applicant for the comparative test, compiles a report containing: - the result of the comparative test stipulated above. This results must demonstrate that the laboratory meets the requirements specified in the standards applicable to the product and/or the additional specifications defined in paragraph 2.2 and that the laboratory is capable of contributing to the NF certification procedure;

71 Certification Rules NF 047 Page 41 of 63 - any observations or comments that they deem appropriate; - The report is sent to EUROVENT CERTITA Certification, which validates it, after having examined the responses of the audited party. The costs of all aforementioned operations shall be borne by the applicant NF authorisation agreement After verification that the application is complete from the administrative, technical and financial point of view, EUROVENT CERTITA Certification approves or rejects NF authorisation specifying the reasons, or delays the decision by recommending an additional investigation. The Special Committee is informed of the authorisations granted by EUROVENT CERTITA Certification NF authorisation validity period The NF authorisation NF is valid for three years from the date when the audit is completed. During this period, the NF authorised laboratory proceeds with annual inspections in accordance with the standards applicable to the product and/or the additional specifications defined in paragraph 2.2, on its secondary set of standard products, with one of the mark's laboratories Laboratory NF authorisation renewal The renewal of NF authorisation is made following a new application and a complete new examination (see ). This procedure is reduced if the laboratory's organisation has not changed and if the systematic examination of the products allowed during this period have not revealed any discrepancy in the results. In this case, these inspections act as comparative tests Post-NF authorisation checks The NF authorised laboratory regularly informs EUROVENT CERTITA Certification of the results of the tests conducted on its secondary set of radiators with one of the NF mark's laboratories, and of any changes to its quality management system that could impact the results of the tests on the products. This information, together with the results of the verifications made pursuant to these certification rules ( systematic and other verifications) are examined by EUROVENT CERTITA Certification which, after evaluation, recommends maintaining, suspending or withdrawing the NF authorisation for all or part of the tests. Any total or partial suspension or withdrawal of accreditation by COFRAC or any equivalent institution recognised by the E.A will lead to a new evaluation of the Laboratory status regarding the NF mark.

72 Certification Rules NF 047 Page 42 of APPLICANT/HOLDER LABORATORIES THAT ARE ACCREDITED NF authorisation application Any applicant/holder with a laboratory approved by COFRAC or any equivalent institution recognised by the E.A (European Cooperation for Accreditation), may request, on the basis of this accreditation, that tests performed in this laboratory and covered by this accreditation, for its products, be considered by EUROVENT CERTITA Certification. The NF authorisation application must be sent to EUROVENT CERTITA Certification, with the following attachments: - a copy of the accreditation decision taken by COFRAC, or an equivalent body recognised by the E.A., specifying the scope thereof (the types of tests); - the report(s) compiled by COFRAC, or an equivalent body recognised by the E.A, as part of the procedure for accreditation by COFRAC, or an equivalent body recognised by the E.A., plus any subsequent reports on verifications made by COFRAC, or an equivalent body recognised by the E.A.; - the commitment to comply with the relevant provisions of the certification rules and its appendices; and, by indicating for which tests the NF authorisation is required, out of those subject to the accreditation by COFRAC, or an equivalent body recognised by the E.A. Prior to any NF authorisation, a comparative test is conducted according to the standards applicable to the product and/or the additional specifications defined in paragraph 2.2, between the applicant's/holder's laboratory and one of the mark's laboratories, on the so-called secondary set of three standard radiators belonging to the laboratory applying for authorisation. The costs of all aforementioned operations shall be borne by the applicant NF authorisation agreement EUROVENT CERTITA Certification studies the application and checks that it is complete. If it is not complete, EUROVENT CERTITA Certification asks for more information. EUROVENT CERTITA Certification approves or rejects the NF authorisation specifying the reasons, or delays the decision by recommending an additional investigation. The Special Committee is informed of the authorisations granted NF authorisation validity period The NF authorisation NF is valid for three years from the date when the audit is completed. During this period, the NF authorised laboratory proceeds with annual inspections in accordance with the standards applicable to the product and/or the additional specifications defined in paragraph 2.2, on its secondary set of standard products.

73 Certification Rules NF 047 Page 43 of Laboratory NF authorisation renewal If the applicant/holder has applied for accreditation by COFRAC, or an equivalent body recognised by the E.A., for its laboratory, then it informs EUROVENT CERTITA Certification of the state of progress of this procedure on the date when it applies for the renewal. a) if the procedure for accreditation by COFRAC, or an equivalent body recognised by the E.A., is not complete, the NF authorisation is renewed after a new application and a new examination, in accordance with paragraph ; b) if the procedure for accreditation by COFRAC, or an equivalent body recognised by the E.A., is complete, there are two possible cases, separately or simultaneously: b1) the laboratory has an accreditation by COFRAC, or any equivalent body recognised by the E.A, for all or part of the tests subject to the expired NF authorisation. In this case, the applicant/holder may ask for renewal of its NF authorisation for said tests according to the procedure described in article 2, for the set time frame in this procedure. b2) the accreditation from COFRAC, or any equivalent body recognised by the E.A, has been withdrawn for all or part of the tests subject to the expired NF authorisation. In this case, the applicant/holder may nevertheless ask for renewal of its NF authorisation for said tests according to the procedure described in 6.1. EUROVENT CERTITA Certification takes a decision on the application for renewal in light of the investigation made by COFRAC, or an equivalent body recognised by the E.A., and of the reasons for the refusal of the accreditation by COFRAC, or an equivalent body recognised by the E.A.. It defines any conditions applying to the renewal by indicating the necessary verifications Post-NF authorisation checks The NF authorised laboratory regularly informs EUROVENT CERTITA Certification of the verifications made by COFRAC, or an equivalent body recognised by the E.A., and of the decisions taken by the latter further to these verifications. This information, together with the results of the verifications made pursuant to these certification rules ( systematic and other verifications) are examined by EUROVENT CERTITA Certification which, after evaluation, recommends maintaining, suspending or withdrawing the NF authorisation for all or part of the tests. Any total or partial suspension or withdrawal of accreditation by COFRAC or any equivalent institution recognised by the E.A will lead to a new evaluation of the Laboratory status regarding the NF mark.

74 TABLE 1: Authorisation procedure for a manufacturer's laboratory with respect to the NF mark (complete or partial tests) MANUFACTURER EUROVENT CERTITA Certification MARK LABORATORY STAGE 1. sends one copy of a complete application file to EUROVENT CERTITA Certification, in accordance with paragraph or The application must also specify the name of the mark's laboratory chosen by the manufacturer to conduct the comparative test in PHASE 2.. records the application and verifies that it is complete,. processes the application,. informs the laboratory of the mark that has been selected,. selects the audit team,. draws up and sends an estimate to the manufacturer, STAGE 2. conducts the NF conformity tests,. draws up the corresponding test report,. keeps the tested product available for the mark's laboratory,. sends the mark laboratory:. the test report,. the documents relative to the products tested. STAGE 3 STAGE 4. examines the whole application (audit result, comparative test results, etc.),. makes a decision based on the results,. notifies its decision to the manufacturer, submitting a copy to laboratory of the mark in question. The certificate specifies the NF authorisation scope (complete or partial tests).. examines the renewal procedure according to the provisions of this part.. conducts the comparative test,. draws up the corresponding test report,. submits the report to EUROVENT CERTITA Certification and to the manufacturer,. issues the corresponding invoice to the manufacturer.

75 TABLE 2: Procedure of complete or partial tests performed by an NF authorised laboratory MANUFACTURER EUROVENT CERTITA Certification MARK LABORATORY STAGE 1. sends EUROVENT CERTITA Certification an application for the right to use the NF mark (see part 8) for its products,. with a view to conducting the examination for PHASE 2, sends the mark laboratory the report of the tests conducted in its NF authorised laboratory as part of its application, in duplicate.. assigns a file number to the application,. processes the application,. issues the corresponding invoices (admission and report evaluation costs), STAGE 2 STAGE 3 STAGE 4. the products are NF certified. They are subject to periodic inspections defined by the mark's certification rules.. examines the test report submitted by the manufacturer,. makes any necessary changes or additions, with the approval of the laboratory,. if necessary, submits the application to the Special Committee.. prepares the certificate.. sends the signed certificate to the holder.

76 Certification reference standard NF 047 Page 46 of 63 Part 7 RATES This part defines rates of services regarding NF certification and describes the collection method. NF certification includes the following services: Application rules development and implementation Processing the certification application Running of the certification application Tests Audits Sampling Right to use the NF Mark Additional verifications (checks) NF Mark promotion 7.1 SERVICES RELATING TO NF CERTIFICATION Type of service Service definition General conditions common to NF marks Registration Implementation of a NF mark - Registration fees are paid by (development and application, elaboration of the the applicant at the initial implement of new application) certification rules included. application for the right to use the NF mark - The certification rules specifies when the registration shall be paid: application, issue of the right to use Processing the certification application Administration of certification application Tests Audit This service includes the examination of application files, exchanges with applicants, laboratories, auditors, evaluation of inspection results/ Services for managing applications for certified products and their holders, drawing up lists of certified products, and assessing inspection results. Test services corresponding to laboratory rates. The service includes the audit preparation, the audit itself and the report. Payment of these services are due even if the right to use the NF Mark is not granted or if the application process is forsaken during processing. Laboratories rates are available in appendix. Payment of this service is due even if the right to use the NF mark is not granted or extended.

77 Certification Rules NF 047 Page 47 of 63 Type of service Service definition General conditions common to NF marks Travel expenses will be added to these services. Sampling Right to use the NF mark Additional specification NF Mark promotion This service includes sampling preparation and the sampling itself. This licensee fee due to AFNOR Certification is intended to cover : Protection of the NF Mark: filing and protection of the mark, legal counsel, processing of misuses (legal services); Contribution to the general promotion of the NF Mark; General operation of the NF Mark (management of the authorities of governance of the NF Mark, quality system...).. Services incurred by additional inspections or verification tests that may prove necessary following insufficiency or anomalies revealed by current inspections. Sector-based promotion actions of the NF Mark. If the sampling is made outside the audit, there will be no charge less than half a day. - When the certification is granted, annual fees of the NF Mark will be charged to the applicant. - When the NF Mark is granted during the year, the annual fees is prorated based on the date of issue of the certificate; - The right to use the NF Mark is due, even in case of withdrawal or suspension during the year. Services are borne by the applicant/holder. Service for which the fees can be defined every year in addition to the other services. 7.2 RATES, TERMS OF PAYMENT AND COLLECTING PAYMENT The document is available on EUROVENT CERTITA Certification website ( or can be sent with a request made at EUROVENT CERTITA Certification.

78 Certification Rules NF 047 Page 48 of 63 Part 8 CERTIFICATION APPLICATIONS The purpose of this part is to give applicants for the right to use the NF mark all the information they need to complete their application PREREQUISITES FOR THE FILING AND EXAMINATION OF APPLICATIONS The minimum conditions to be met in order to submit an application are defined in paragraph 1.2 of these certification rules TYPES OF APPLICATIONS The different types of applications are defined in part PRESENTATION OF THE APPLICATION The complete application for the right to use the NF mark must be sent to: 48 / 50 rue de la Victoire F PARIS Telephone:+ 33 (0) Fax: Site : certita@certita.fr EUROVENT CERTITA Certification examines the application. If the product comes from a manufacturing unit outside the European Union, the applicant will appoint a French mandated body or a representative within the European Union who jointly signs the application. An application concerning a product availing of a foreign conformity mark or a test certificate issued by a foreign laboratory is processed according to existing recognition agreements, in accordance with the general rules of the NF Mark.

79 Certification Rules NF 047 Page 49 of Applications for the right to use the NF mark The applicant compiles, in French or English, a standard application, the contents of which, in addition to the general documents described hereafter, are defined in part 9 "Additional specifications". All the documents are to be sent to EUROVENT CERTITA Certification. Depending on the type of application, the following general documents are used: - Application for admission:. standard letter 001,. general information form "F-02" regarding the applicant. This form must be provided when making a first application for the right to use the NF mark or when changes are made to the information.. standard form F-03 "MANDATED BODY". This form must be provided if the applicant is not located in the European Economic Area.. form F-04 "CONTRACT". This form must be provided if the applicant subcontracts any of the requirements defined in paragraph Subsequent applications for admission:. standard letter 001,. standard form F-03 "MANDATED BODY". This form must be provided if the applicant is not located in the European Economic Area.. form F-04 "CONTRACT". This form must be provided if the applicant subcontracts any of the requirements defined in paragraph Applications for extension:. standard letter 002,. standard form F-03 "MANDATED BODY". This form must be provided if the applicant is not located in the European Economic Area. - Applications for maintenance:. standard letter 003,. standard engagement form for beneficiaries F-01. This form must be used if the application for maintenance is for a third party,. commercial document (if available).

80 Certification Rules NF 047 Page 50 of 63 STANDARD LETTER: 001 APPLICATION FOR THE RIGHT TO USE THE NF MARK (to be drawn up on the applicant's headed paper) EUROVENT CERTITA Certification M. le Directeur Général, à l attention du chargé d affaire rue de la Victoire PARIS (FRANCE) subject: NF- Radiators, Convectors and Ceiling-mounted radiant panels, hot water heating, fan assisted and mixed Application for the right to use the NF mark and commitment Dear Sir, I am writing to apply for the right to use the NF mark for the range designated below: Trademark:... Trade name:... produced in the following manufacturing unit: Company name:... Address:... In this respect, I declare knowledge and acceptance of the General Rules of the NF Mark and the NF 047 certification rules, with its appendices, and undertake to comply thereto throughout the period of use of the NF mark.

81 Certification Rules NF 047 Page 51 of 63 (1) <Moreover, I hereby authorise the Company (company name), (status of the company), (head office) represented by Mr./Ms. (name of the legal representative), in their capacity as (quality), to represent me in France for all questions relating to the use of the NF 047 Mark. I undertake to inform EUROVENT CERTITA Certification immediately of any change in the aforementioned representative>. <OPTION: For such purposes, I ask that the fees incumbent on me be invoiced directly to him/her. He/she will directly pay them on my behalf upon receiving the invoices, as s/he so undertakes when accepting to be my representative.> Yours faithfully. (2) Date and signature Date and signature of the representative in of the legal representative the European Economic Area of the applicant (1) Delete as appropriate (2) Compulsory for applicants/holders outside the European Union and optional for all others.

82 Certification Rules NF 047 Page 52 of 63 STANDARD LETTER: 002 APPLICATION FOR EXTENSION OF THE RIGHT TO USE THE NF MARK FOR A MODIFIED RANGE OR NEW MODELS (to be drawn up on the applicant's headed paper) EUROVENT CERTITA Certification M. le Directeur Général, à l attention du chargé d affaire rue de la Victoire PARIS (FRANCE) subject: NF- Radiators, Convectors and Ceiling-mounted radiant panels, hot water heating, fan assisted and mixed Application for the extension of the right to use the NF mark for a modified range or new models and commitment. Dear Sir, As a holder of the NF mark for the product manufactured by me under the following reference:. production unit: (<corporate name> <address>). trademark:. trade designation:. right to use granted by certificate number (certificate number) dated (date) I am writing to apply for the right to use the NF Mark for the range of my own production, deriving from the NF certified range with the following modifications: - New model(s) new height(s):... - Other reasons (subject to prior approval):...

83 Certification Rules NF 047 Page 53 of 63 (1) <Moreover, I hereby authorise the Company (company name), (status of the company), (head office) represented by Mr./Ms. (name of the legal representative), in their capacity as (quality), to represent me in France for all questions relating to the use of the NF 047 Mark. I undertake to inform EUROVENT CERTITA Certification immediately of any change in the aforementioned representative. <OPTION> For such purposes, I ask that the fees incumbent on me be invoiced directly to him/her. He/she will directly pay them on my behalf upon receiving the invoices, as s/he so undertakes when accepting to be my representative. I hereby declare that the other characteristics of the range concerned by this application are in strict compliance with the products that are already NF certified and manufactured in the same conditions. Yours faithfully. (2) Date and signature Date and signature of the representative in of the legal representative the European Economic Area of the holder (1) Compulsory for applicants/holders outside the European Union and optional for all others.

84 Certification Rules NF 047 Page 54 of 63 STANDARD LETTER: 003 APPLICATION FOR THE MAINTENANCE OF THE RIGHT TO USE THE NF MARK (To be drawn up on the holder's headed paper) EUROVENT CERTITA Certification M. le Directeur Général, à l attention du chargé d affaire rue de la Victoire PARIS (FRANCE) subject: NF- Radiators, Convectors and Ceiling-mounted radiant panels, hot water heating, fan assisted and mixed Application to maintain the right to use the NF mark Dear Sir, I am writing to you to apply for the maintenance of the right to use the NF mark for the range that only differs from the NF certified range in name and/or trade mark. This application applies to: Production unit: (corporate name) (address). NF CERTIFIED RANGE(S) NEW TRADE NAME Certificate N Trade name Trademark Trade range Trade name (*) (*) For simultaneous applications (for example: admission, maintenance), the column is not completed. This new trade name replaces the old trade name.. NO (1). YES (1)

85 Certification Rules NF 047 Page 55 of 63 (2) Representative of the holder <Moreover, I hereby authorise the Company (company name), (status of the company), (head office) represented by Mr./Ms. (name of the legal representative) in their capacity as (quality) to represent me in France for all questions relating to the use of the NF 047 Mark. I undertake to inform EUROVENT CERTITA Certification immediately of any change in the aforementioned representative. Invoicing: - administrative costs of the examination of this application (3) At the holder of the right to use the NF Mark (origin of the range). I ask that these expenses are directly charged to me. At the holder s representative mentioned above. I ask that these expenses which are under my responsibility are directly charged to it. The holder s representative will insure the payment when it will receive the invoice as it commits by accepting the representation. At the Company beneficiary of the maintenance of the right to use. I ask that these expenses which are in my charge are directly charged to it. - Administrative operating costs according to 7.6 of these Rules (3) At the holder of the right to use the NF Mark (origin of the range). I ask that these expenses are directly charged to me. Yours faithfully. At the holder s representative mentioned above. I ask that these expenses, which are under my responsibility, are directly charged to it. The holder s representative will insure the payment when it will receive the invoice as it commits by accepting the representation. At the Company beneficiary of the maintenance of the right to use. I ask that these expenses which are in my charge are directly charged to it. (2) Date and signature Date and signature of the representative in of the legal representative the European Economic Area of the holder (4) Date and signature of the beneficiary (1) Delete as appropriate (2) Compulsory for applicants/holders outside the European Union and optional for all others. (3) Cross the case concerned (4) Only applied to the application for the maintenance for third parties.

86 Certification Rules NF 047 Page 56 of 63 FORM F-01 BENEFICIARY COMMITMENT (To be drawn up on the beneficiary's headed paper) I, the undersigned,... acting in my capacity as (owner, president, General Manager)... of the company: - Company name:... - Address: Country:... - Tel.: Web: SIRET N (1):... APE Code (1):... - VAT Identification N :... (1) Only for French companies Hereby I commit: - Not to make any technical modification regarding the nature and/or working features of the products describes below : NF CERTIFIED RANGE(S) NEW TRADE NAME Registration n (*) Trade name Brand name Trade range Trade name (*) in case of simultaneous application (admission and maintenance), do not fill the column. - Not to make other modifications that change certified characteristics of the products manufactured by the company <Company>. such as <details of modifications> ; - Any subsequent change must be notified for agreement to EUROVENT CERTITA CERTIFICATION beforehand and agreed with the holder;

87 Certification Rules NF 047 Page 57 of 63 - Not to modify the aforementioned trade names unless in agreement with the manufacturer who holds the right to use the NF Mark; - Not to make any modification to these trades names without having first informed EUROVENT CERTITA CERTIFICATION by letter; - Not to modify any marking on the products done by the older, in accordance with the provisions of this NF-047 certification rules, which the undersigned declared to have acknowledged; - To collaborate with EUROVENT CERTITA CERTIFICATION on any verification regarding the products in question and their marketing; - To apply the measures resulting from penalties taken in conformity with this NF-047 Rules which the undersigned declared to have acknowledged, that during all time using the right to use the NF Mark; - To pay the admission fees as foreseen by the rates mentioned in part 7 and any payments which will be requested in compliance with this certification Rules NF047; - To inform the holder of any claims received related to the certified products. Date, Name and signature of the legal representative of the beneficiary of maintenance

88 Certification Rules NF 047 Page 58 of 63 FORM F-02 GENERAL DATA SHEET CONCERNING THE APPLICANT APPLICANT: - Company name:... - Address: Country:... - Tel.:... - Fax: (of the company): Web: SIRET N (1):... APE Code (1):... - VAT Identification N : Name and position of the legal representative (2):... - Name and position of contact (if different):... MANUFACTURER (if different from the manufacturing unit): - Company name:... - Address: Country:... - Tel.:... - Fax: Web: (1) Only for French companies (2) The legal representative is the person who is legally responsible for the company

89 Certification Rules NF 047 Page 59 of 63 - SIRET N (1):... APE Code (1):... - VAT Identification N : Name and position of the legal representative (2):... - Name and position of contact (if different):... Correspondent's Name of the quality officer:... - French-speaking person (for foreign companies):... (1) Only for French companies (2) The legal representative is the person who is legally responsible for the company

90 Certification Rules NF 047 Page 60 of 63 FORM F-03 MANDATED BODY EXAMPLE OF A MANDATE List of the information to be provided: Company name: Address: Country: Telephone: Fax: SIRET N 1 : NAF code 1 : Name and position of the legal representative 2 : Name and position of contact (if different): VAT identification number 3 : address of contact person: address of the Company: Web: Identification of the functions of the mandated body to be specified in the mandate between the applicant/holder and the mandated body Applicant/Holder:... Mandated body:... Minimum requirements which must be included in the mandate: Mandate: assignments and associated responsibilities financial aspects claims certifying body contact The mandate must be registered in the applicant's/holder's quality system. A copy of the mandate in French or English must be enclosed with the co-signed application for admission. Respect of the mandate will be audited. Date of the initial mandate Modification dates: 1 2 Subject of the modification Cosignature

91 Certification Rules NF 047 Page 61 of 63 FORM F-04 CONTRACT OF SERVICE PROVIDER A form is provided to define the contractual ties between the applicant and the various service provider(s), to which it subcontracts any aspect(s) specified in paragraph 3.2 of these Rules. The form must be updated and sent to EUROVENT CERTITA Certification when any changes are made to the contract or if the service provider is replaced. A form must be drawn up in French and in English (if relevant) for each service provider and for each of the previously defined aspects. Applicant/Holder:... EXAMPLE OF A CONTRACT Between the two Companies signatory: The Company Legal Company Name of the applicant/holder, address, represented by Name and function, duly authorized, Below named the applicant/holder On one hand, And The Company Legal Company Name service provider, address, represented by Name and function, duly authorized, Below named the service provider On the other hand, Minimum requirements which must be included in the contract: - the service provider must commit to meeting the requirements of the certification rules of the corresponding NF-047 application; - management of customer complaints by the applicant/holder in coordination with the service provider; - management of complaints among service providers by the applicant/holder; - as part of the design work, the holder of the intellectual property shall be designated; it shall inform the other party of any change in the design drawings,

92 Certification Rules NF 047 Page 62 of 63 - the service provider shall inform the applicant/holder of any changes to its quality management system, and in particular of any instances of non-conformity detected by internal inspections or external audits; - the service provider accepts the possible presence of the representative of the applicant/holder during the admission audits and during monitoring of NF certification. - the applicant/holder must commit to inform the service provider of any change in the certification of the products covered by the NF Mark. Done at.. On the. In two original copies, one for each party. For Legal Company Name of the holder/applicant Name function For Legal Company Name of the service provider Name function Signature Signature

93 Certification Rules NF 047 Page 63 of 63 Part 9 Additional specifications This part specifies the specific requirements applicable to the products covered by these certification rules in the form of appendices: Appendix A: specific requirements for radiators and convectors with hot water heating Appendix B: specific requirements for ceiling-mounted radiant panels with hot water heating Appendix C: specific requirements for fan-assisted radiators and convectors Appendix D: specific requirements for mixed radiators

94 PART 9 - APPENDIX A CERTIFICATION RULES Radiators, Convectors and Ceiling-mounted radiant panels, hot water heating, fan assisted and mixed SPECIFIC REQUIREMENTS FOR HOT WATER HEATING RADIATORS AND CONVECTORS CONTENTS 9A-1 Scope 9A-2 Reference documents 9A-3 Definitions 9A-4 Technical specifications and characterisation methods 9A-5 Quality control specifications 9A-6 Specific test methods 9A-7 Certification file 9A-8 Provision on documentation Identification N : NF 047 Revision N : 14 Date of application: 12/12/2016

95 Certification Rules NF 047 Page 2 of 28 9A-1. SCOPE This appendix of the NF-047 Rules specifies the specific requirements applying to the radiators and convectors fed with hot water covered by the standard NF EN 442 (see the edition of the standard in 9A-2) for their heating function. This rules does not apply any thermal output limits for the certification of products. The power of products that is below or above the limits defined in the standard NF EN 442 (see the edition of the standard in 9A-2) for the execution of tests is determined by calculation. The certified characteristics are: The thermal power. The maximum operating pressure. 9A-2. REFERENCE DOCUMENTS The standards listed above take into account the mean standards but they are not exhaustive. The following standards are applicable to the products: NF EN 442-1: December 2014, Radiators and convectors Part 1: technical specifications and requirements. NF EN 442-2: December 2014, Radiators and convectors Part 2: test methods and rating. NF EN 10204: January 2005, Metallic products - types of inspection documents 9A-3. DEFINITIONS The definition of the products and procedures can be found in the standard NF EN 442 (parts 1 and 2) (see the edition of the standard in 9A-2). 9A-4. TECHNICAL SPECIFICATIONS AND CHARACTERISATION METHODS 9A-4.1 Determination of the output of the appliances The number of products is selected and the output is determined according to the test methods defined in the standard NF EN (see the edition of the standard in 9A-2). The thermal output of panel radiators is determined with the appliances fitted at least with their grill and side plates, if this version is contained in the applicant's / holder's catalogue. If he so wishes, the applicant/holder can ask the laboratory to test a number of appliances that is higher than the number specified in the standard NF EN (see the edition of the standard in 9A-2).

96 Certification Rules NF 047 Page 3 of 28 For horizontal water flow radiators, for which the proportionality versus the length is not necessarily verified, the applicant/holder can ask for several lengths of the selected model to be tested. If, in certain special cases, the selection method described in the standard NF EN 442 (see the edition of the standard in 9A-2) or in the test procedure cannot define them, then EUROVENT CERTITA Certification is free to choose the models, possibly together with one of the mark's laboratories. 9A-4.2 Mechanical resistance and deformation of the appliances Plate radiators made of flat tubes must be tested at a pressure 1.3 times the maximum operating pressure declared by the applicant in its application for the right to use the NF mark, in order to measure their permanent deformation. The test pressure must not be lower than 5.2 bar. The conformity of the products is confirmed if the ratio between the initial and final measurements (after pressurisation) is lower than 10%. Selecting the products for the initial tests (applications for the right to use the NF mark): The appliances used to determine the thermal output shall be tested. Selecting the products for the control tests: The appliance must be at least 500 mm long, and it is preferable to select a product that is close to 1 meter in length. Test method The measurements are taken as follows: The measure shall to be made with an appliance enabling to measure the thickness on a contact point (such as a caliper with mouthpiece contact point (or hook), a micrometer ). 1- Initial measurement: The thickness is measured at six points on the product as follows:. For panel radiators: On multi-panel radiators, the measurement is made on a single panel. The measurements are made half-way up the collectors: three at the top and three at the base. For each collector, the first two measurements are made one third of the way along the length of the radiator at each extremity and third is made half-way along the length. If obstacles, such as convention fins or reinforcing spacers, prevent the measurements from being made, then the point of measurement can be moved slightly to the left or the right.

97 Certification Rules NF 047 Page 4 of 28. For flat tube radiators: Measurements on radiators with multiple rows of tubes are made on a single row. The measurements are made in the middle of the width of the first tube of the radiator: three on one side, and three on the other side. For each tube, the first two measurements are made one third of the way along the length (or half-way up the height, depending on the orientation of the tubes) of the radiator at each extremity and third is made half-way along the length. If obstacles, such as convention fins or reinforcing spacers, prevent the measurements from being made, then the point of measurement can be moved slightly to the left or the right.. For lamellar radiators: The measurement is made on one side of the radiator. The measurements are made in the middle of the depth of the first plate of the radiator: three on one side, and three on the other side. For each plate, the first two measurements are made one third of the way up the height of the radiator at each extremity and third is made half-way up the height. 2 - Application of the test pressure using the selected process: - Water test: The test is performed using a test pump or a suitable hydraulic test circuit. The accuracy of the pressure manometer has be at least ±5%. After having filled and drained the radiator, gradually and smoothly apply and maintain the test pressure for 10 minutes. - Air test: The test apparatus comprises: - a tank filled with water and its accessories. - a pneumatic circuit capable of delivering the required pressure. Gradually and smoothly apply the air pressure to the radiator submerged in water for 2 minutes. 3- Final measurement: After having relieved the pressure inside the appliance, repeat the measurements at the same points as the initial measurements. 9A-5. QUALITY CONTROL SPECIFICATIONS The quality control provisions stated in part 2 of this rules apply to these products.

98 Certification Rules NF 047 Page 5 of 28 The manufacturer must also apply the requirements specific to the products: Paragraph 9A Steel panel and plate radiators, Paragraph 9A Steel tube radiators Paragraph 9A Aluminium alloy radiators Paragraph 9A Extruded aluminium radiators Paragraph 9A Cast iron radiators Paragraph 9A Convectors 9A STEEL PANEL AND LAMELLAR RADIATORS 9A Inspection of the components and raw materials. The manufacturer shall inspect the components used to manufacture the appliances or take other measures necessary to guarantee the conformity of purchased products. Special attention shall be paid to the following parts: for lamellar radiators:. the connections For panel radiators:.the connections (fittings). the reinforcing rings. the integrate tube. the grill. The manufacturer shall imperatively check the thickness and surface condition of steel coils (no rust or scaling). The steel plates used has to be conform to the specifications related to the material and the thickness of the wet surface of the wall defined in the standard NF EN (see the edition of the standard in 9A-2). It is advisable to ask for an analysis certificate for every supply (in accordance with the standard NF EN paragraph 2.2 (see the edition of the standard in 9A-2)), that specifies the chemical composition and the mechanical characteristics of the product. Otherwise, the manufacturer must be able to receive this information from the supplier.. For the paint, it is advisable to ask for an analysis certificate for every supply, specifying the characteristics of the batch. Otherwise, the manufacturer must be able to receive this information from the supplier. 9A Dimensional inspections during production The manufacturer must perform for each production line at least the following inspections, in accordance with its own sampling plan. Inspections shall be made whenever changes are made to the manufacturer program or at least once a day.

99 Certification Rules NF 047 Page 6 of 28 List of inspections and acceptance tolerances (in mm): For panel radiators. Inspection of the connection centre-to-centre distance tolerance ± 2. Inspection of the overall depth tolerance ± 2,5. Inspection of the overall height tolerance: H 900 mm, +4/-2; 900mm<H, +5/-2. Inspection of the overall length tolerance: L mm, ±2; 1 000mm<L, ± 0,25%. Inspection of the squareness of the radiator on the two axes (x, y) tolerance +2. Inspection of the depth of the fins - tolerance ± 1. Inspection of the height of the fins - tolerance +3/-1. Inspection of the depth of the water channels or the collector tolerance ± 1 For lamellar radiators. Inspection of the connection centre-to-centre distance tolerance ± 2. Inspection of the overall depth tolerance ± 2,5. Inspection of the overall height tolerance: H 900 mm, +4/-2; 900mm<H, +5/-2. Inspection of the overall length tolerance: L mm, ±3; 1 000mm<L, ± 0,5% 9A Mechanical resistance tests and deformation measurements Mechanical resistance to pressure must be tested in accordance with paragraph 9A-4.2. Samples must be taken at least once a month. The selected samples must be representative of the production output. 9A Weld inspections The manufacturer must check the quality of the welds on the radiator by performing destructive or nondestructive tests defined according to a suitable method and reproducible. A test with a hammer cannot be considered as reproducible. The manufacturer has to give priority to performing the inspection by a measure of one force with adapted device as a torque wrench, for example. Inspections must be made at least once a day on the following parts: For panel radiators. on the connections. on the fitting supports (if any). on the reinforcing spacers. on the fins The manufacturer has to define the evaluation criteria of the conformity of the results. Nevertheless, the manufacturer has to demonstrate how it has established the criteria in accordance with a documented study. 9A Build inspection for panel radiators with covers on front plate If the manufacturer produces radiators with covers on the front plate, he shall draw instructions describing the attachment process, which he commands perfectly.

100 Certification Rules NF 047 Page 7 of 28 9A TUBE RADIATORS 9A Inspection of the components and raw materials. The manufacturer must inspect the components used to manufacture the appliances or take other measures necessary to guarantee the conformity of products. Special attention shall be paid to the following parts:. joins and covers,. the grills (if relevant). For steel tubes/sections, the manufacturer must inspect the thickness, diameter, height, width and the surface condition. The tubes/sections has to be conform to the specifications related to the material and the thickness wet surface of the wall defined in the standard NF EN (see the edition of the standard in 9A-2). It is advisable to ask for an analysis certificate for every supply (in accordance with the standard NF EN paragraph 2.2 (see the edition of the standard in 9A-2)), that specifies the chemical composition and the mechanical characteristics of the product. Otherwise, the manufacturer must be able to receive this information from the supplier.. The manufacturer shall check the thickness and surface condition of steel coils. It is advisable to ask for an analysis certificate for every supply (in accordance with the standard NF EN paragraph 2.2 (see the edition of the standard in 9A-2)), specifying in particular the chemical composition and the mechanical characteristics of the product. Otherwise, the manufacturer must be able to receive this information from the supplier.. For the paint, it is advisable to ask for an analysis certificate for every supply, specifying the characteristics of the batch. Otherwise, the manufacturer must be able to receive this information from the supplier. 9A Dimensional inspections during production The manufacturer must perform at least the following inspections, in accordance with its own sampling plan. Inspections shall be made on each production line whenever changes are made to the manufacturer program or at least once a day. List of inspections and acceptance tolerances (in mm): For tubular radiators (design and towel radiator). Inspection of the connection centre-to-centre distance tolerance ± 2. Inspection of the overall depth tolerance ± 1,5. Inspection of the overall height tolerance: H 900 mm, +4/-2 ; 900mm<H, +5/-2. Inspection of the overall length tolerance: L mm, ±4 ; 1 000mm<L, ± 0,4%. Inspection of the depth of the fins tolerance ± 1. Inspection of the height of the fins (if relevant) tolerance +3/-1. Inspection of the bending of the radiator (if relevant) - -tolerance ± 5

101 Certification Rules NF 047 Page 8 of 28 For multi column radiators. Inspection of the connection centre-to-centre distance tolerance ± 2. Inspection of the overall depth tolerance ± 1,5. Inspection of the overall height tolerance: H 900 mm, +4/-2; 900mm<H, +5/-2. Inspection of the length of the element and/or overall Tolerance per element as specification of the manufacturer Overall tolerance L mm, ±4; 1 000mm<L, ± 0,4%. Inspection of the squareness of the radiator on the two axes (x, y) tolerance +2 9A Mechanical resistance tests and deformation measurements Mechanical resistance to pressure must be tested in accordance with paragraph 9A-4.2 on radiators produced with flat tubes. Test must be taken at least once a month. The selected samples must be representative of the production output. The manufacturer can realize the tests on finished product without coating or on tubes selected in the stock. In the latter case, the manufacturer has to select randomly two tubes in the stock and cut them at two meters length. Tubes are joined together and welded in their extremities to avoid any leak; besides, the connections are welded to alloy to put the pressure in the tubes. Three points of measure are to be marked on the middle point of the width of the tube, for each tube. One on the middle of the length of the sample and the two others at 600 mm from the edge of tube. The measure and the evaluation of the conformity are done according to the method described in 9A A Weld inspections The manufacturer must check the quality of the welds by performing destructive or non-destructive tests defined according to a suitable method and reproducible. A test with a hammer cannot be considered as reproducible. The manufacturer has to give priority to perform the inspection by a measure of the force with adapted device as a torque wrench, for example. Inspections must be made at least once a day on the following parts:. on the connections (if electric welds),. on the fitting supports (if any and if electric welds),. on the fins. The manufacturer has to define the evaluation criteria of the conformity of the results. Nevertheless, the manufacturer has to demonstrate how it has established the criteria in accordance with a documented study. 9A Build inspection for radiators with covers If the manufacturer produces radiators with covers on the front, he shall draw instructions describing the attachment process, which he commands perfectly.

102 Certification Rules NF 047 Page 9 of 28 9A ALUMINIUM ALLOY RADIATORS 9A Inspection of the components and raw materials. The manufacturer shall inspect the components used to manufacture the appliances or take other measures necessary to guarantee the conformity of purchased products. Special attention shall be paid to the following parts:. the joins. the nipples. For aluminium alloy, the manufacturer shall perform a spectrometric test on every batch. The aluminium has to be conform to the specifications related to the material and the thickness wet surface of the wall defined in the standard NF EN (see the edition of the standard in 9A-2). It is advisable to ask for an analysis certificate for each supply, specifying in particular the chemical composition and the mechanical characteristics of the product. Otherwise, the manufacturer must be able to receive this information from the supplier.. If steel tubes are used, the manufacturer must check their thickness. It is advisable to ask for an analysis certificate for every supply (in accordance with the standard NF EN paragraph 2.2 (see the edition of the standard in 9A-2)), specifying in particular the chemical composition and the mechanical characteristics of the product. Otherwise, the manufacturer must be able to receive this information from the supplier.. For the paint, it is advisable to ask for an analysis certificate for every supply, specifying the characteristics of the batch. Otherwise, the manufacturer must be able to demand this information from the supplier. 9A Inspections during production The manufacturer must perform at least the following inspections, in accordance with its own sampling plan. Inspections shall be made whenever changes are made to the manufacturer program or at least once a day. List of inspections and acceptance tolerances (in mm):. Inspection of the aluminium alloy in the melting furnace tolerance as specification of the standard. Inspection of the flatness of the bearings or the squareness of the battery Tolerance:. on the flatness of the bearings, as the specification of the manufacturer. on the squareness, +4/10 elements. Inspection of the threads of the connections,. Inspection of the tightening torque of the nipples tolerance as specification of the manufacturer. Inspection of the centre-to-centre of the couplings (after threading the part) tolerance +0,8/-1,2. Inspection of the overall depth per element (*) tolerance +0/-1. Inspection of the overall height tolerance ±2,5. Inspection of the overall length per element (*) tolerance ±0,2

103 Certification Rules NF 047 Page 10 of 28. Inspection of the height of the convection surfaces (*) tolerance +0,2/-0,8. Inspection of the depth of the convection surfaces (*) tolerance +0,2/-0,8 (*) These inspections can be made when checking the moulds (validation/maintenance) 9A Validation and maintenance of the moulds The manufacturer shall write and apply procedures for the validation and maintenance of the moulds. When validating the moulds, all the dimensions of the part must be measured in accordance with the drawing and the results of the inspections must be recorded in a report. For maintenance, each operation must be recorded in the mould's file. Any significant changes must be validated (see above). 9A Destructive inspections The manufacturer must make sure that the minimum thickness of the wet surface is no less than the thickness defined in the standard NF EN (see the edition of the standard in 9A-2) by taking daily and random product samples. 9A EXTRUDED ALUMINIUM RADIATORS 9A Inspection of the components and raw materials. The manufacturer shall inspect the components used to manufacture the appliances or take other measures necessary to guarantee the conformity of purchased products. Special attention shall be paid to the following parts:. the joins. the nipples. For sections, the manufacturer must inspect the diameter of the water channel and the thickness. The sections have to be conform to the specifications related to the material and the thickness of the wet surface of the wall, defined in the standard NF EN (see the edition of the standard in 9A-2). If aluminium ingots are used, the manufacturer shall perform a spectrometric test on every batch. The aluminium has to be conform to the specifications related to the material and the thickness of the wet surface of the wall defined in the standard NF EN (see the edition of the standard in 9A-2).. If the heads are purchased, the manufacturer must check the diameter of the nipples.

104 Certification Rules NF 047 Page 11 of 28 For every delivery of aluminium ingots, heads and sections, it is advisable to ask for an analysis certificate, specifying in particular the chemical composition of the product. Otherwise, the manufacturer must be able to receive this information from the supplier.. For the paint, it is advisable to ask for an analysis certificate for every supply, specifying the characteristics of the batch. Otherwise, the manufacturer must be able to receive this information from the supplier. 9A Inspections during production The manufacturer must perform at least the following inspections, in accordance with its own sampling plan. Inspections shall be made whenever changes are made to the manufacturer program or at least once a day. List of inspections and acceptance tolerances (in mm):. Inspection of the aluminium alloy in the melting furnace (where appropriate) Tolerance according to the specifications of the standard. Inspection of the flatness of the bearings or the squareness of the battery Tolerance:. for the bearings, according to the specification of the standard. for the squareness, +4/10 elements. Inspection of the threads of the couplings. Inspection of the tightening torque of the nipples tolerance according to the specification of the manufacturer. Inspection of the connection centre-to-centre distance tolerance +0/-1,2. Inspection of the overall depth (*) - tolerance ±0,65. Inspection of the overall height- tolerance ±2,5. Inspection of the overall length of the element tolerance ±0,65. Inspection of the height of the convection surfaces (*) - tolerance +0,2/-0. Inspection of the depth of the convection surfaces (*) tolerance +0,2/-0 (*) These inspections can be made when checking the moulds or stamps (validation/maintenance) 9A Validation and maintenance of the moulds. If the manufacturer makes aluminium alloy heads, then he shall write and apply procedures for the validation and maintenance of the moulds. When validating the moulds, all the dimensions of the part must be measured in accordance with the drawing and the results of the inspections must be recorded in a report. For maintenance, each operation must be recorded in the mould's file. Any significant changes must be validated (see above).. If the manufacturer outsources the production of the heads, then he must take the steps required to monitor and control the supplier(s). The moulds must be validated under the same conditions as above.

105 Certification Rules NF 047 Page 12 of 28 9A CAST IRON RADIATORS Inspection of the components and raw materials. The manufacturer shall inspect the components used to manufacture the appliances or take other measures necessary to guarantee the conformity of purchased products. Special attention shall be paid to the following parts:. the joins. the nipples - for the smelting:. the ferro-silicon. the ferro-manganese. the phosphorous - for the moulding:. the back mineral. the bentonite - for the coring:. the resin. The manufacturer must make regular inspections of the components listed below. It is advisable to ask for an analysis certificate for each supply, specifying in particular the chemical composition and the mechanical characteristics of the product. Otherwise, the manufacturer must be able to receive this information from the supplier. List of components:. new cast iron (the grey cast iron) has to be conform to the specifications related to the material and the thickness of the wet surface of the wall, defined in the standard 4.2 of the standard NF EN442-1 (see the edition of the standard in 9A-2).. the moulding silica sand (granulometry checks). the coring silica sand (granulometry checks). For the paint, it is advisable to ask for an analysis certificate for every supply, specifying the characteristics of the batch. Otherwise, the manufacturer must be able to demand this information from the supplier. 9A Inspections during production The manufacturer must perform at least the following inspections, in accordance with its own sampling plan. Inspections shall be made whenever changes are made to the manufacturer program or at least once a day.

106 Certification Rules NF 047 Page 13 of 28 List of inspections and acceptance tolerances (in mm): For the moulding sand:. compressibility check. shear check. humidity check. permeability check For the coring:. check of the dimensions of the bearings tolerance according to the specification of the manufacturer. check for air ducts For the smelting:. check of the temperature of the furnaces. spectrometric analysis of the cast iron For machining and assembly:. inspection of the threads of the couplings. inspection of the position of the connections with the part, horizontally and vertically. tolerance according to the specification of the manufacturer. inspection of the equidistance of the blade bearings - tolerance according to the specification of the manufacturer. inspection of the flatness of the bearings - tolerance according to the specification of the manufacturer. tightening torque check - tolerance according to the specification of the manufacturer. inspection of the length - tolerance ± 1,5% mm. inspection of the centre-to-centre of the connection (after threading the part) tolerance ± 0,5 mm Other inspections:. inspection of the height (*) tolerance ± 4 mm. inspection of the depth (*) tolerance ± 2 mm. inspection of the height of the convection surfaces (*) tolerance +3/-1,5 mm. inspection of the depth of the convection surfaces (*) tolerance ± 1,5 mm (*) These inspections can be made when checking the models (validation/maintenance) 9A Validation and maintenance of the core boxes and model plates The manufacturer shall write and apply procedures for validation and maintenance. When validating, all the dimensions of the part must be measured in accordance with the drawing and the results of the inspections must be recorded in a report. For maintenance, each operation must be recorded in a file. Any significant changes must be validated (see above).

107 Certification Rules NF 047 Page 14 of 28 9A Destructive inspections The manufacturer must make sure that the minimum thickness of the wet surface is no less than the thickness defined in the standard NF EN (see the edition of the standard in 9A-2) by taking daily and random product samples. 9A CONVECTORS 9A Inspection of the components and raw materials. For purchased couplings, the manufacturer must proceed with inspections or other activities that are necessary to make sure that the product is compliant.. The manufacturer shall check the thickness and surface condition of steel, aluminium or other coils. It is advisable to ask for an analysis certificate for every supply (in accordance with the standard NF EN paragraph 2.2 (see the edition of the standard in 9A-2)), specifying in particular the chemical composition and the mechanical characteristics of the product. Otherwise, the manufacturer must be able to receive this information from the supplier.. The manufacturer shall check the thickness and surface condition of tubes.. It is advisable to ask for an analysis certificate for every supply (in accordance with the standard NF EN paragraph 2.2 (see the edition of the standard in 9A-2)), specifying in particular the chemical composition and the mechanical characteristics of the product. Otherwise, the manufacturer must be able to receive this information from the supplier.. The coils (steel, aluminium, or other) and the tubes have to be conform to the specifications related to the material and the thickness of the wet surface of the wall, defined in the standard 4.2 of the standard NF EN442-1 (see the edition of the standard in 9A-2).. For the paint, it is advisable to ask for an analysis certificate for every supply, specifying the characteristics of the batch. Otherwise, the manufacturer must be able to receive this information from the supplier. 9A Inspections during production The manufacturer must perform at least the following inspections, in accordance with its own sampling plan. Inspections shall be made whenever changes are made to the manufacturer program or at least once a day. List of inspections and acceptance tolerances (in mm): For the fins: Height tolerance ± 0,5 Depth tolerance ± 0,5 For the casing: Height - tolerance: H 900 mm, +4/-2; 900mm<H, +5/-2 Length - tolerance: H 900 mm, ±5; 900mm<H, ± 0,5% Depth - tolerance +4/-3. Check of all the dimensions of the casing (height, length, depth)

108 Certification Rules NF 047 Page 15 of 28 9A-6 SPECIFIC TEST METHODS There are no specific test methods. The methods described in the standard NF EN (see the edition of the standard in 9A-2) shall apply. 9A-7 CERTIFICATION APPLICATION In addition to the general documents specified in Part 8, the applicant shall also supply the documents in the table below: DOCUMENTS TO BE SUPPLIED NUMBER OF COPIES A technical data sheet for the product range, as per the standard data sheet "FA-01a" or "FA-01b". The manufacturing plan, in accordance with the instructions in FA- 02 Test reports and/or catalogue from a laboratory that:. possesses the NF mark,. is part of the RADMAC agreements,. is notified, as per regulation n 305/2011 (Construction products) Declaration of conformity - FA-03 1 Photograph or commercial document (optional)

109 Certification Rules NF 047 Page 16 of 28 FA-01a TECHNICAL DATA SHEET VERTICAL water flow radiators Example of products to which this data sheet applies Height Height Height Height Centre- Centre- Centre- Centre- Pitch Pitch Pitch Pitch Panels Panels Radiators Radiators Vertical section (steel, tube Cast iron, aluminium, etc.) 1 - GENERAL INFORMATION: - Trade name. Trademark:. Trade range:. Trade designation:. Trade designation with fittings grill and side plates (if any):

110 Certification Rules NF 047 Page 17 of 28 - Production unit:. Company name:. Address: - Material(s):. Composition: (if different from the composition described in the standard NF EN 442 (see the edition of the standard in 9A-2). Specify the nature) - Pitch (mm): - Depth "P1" of the emitter (in mm): P2 P1 P1+P2 - Overall depth "P2" (mm): P1+P2 P1+P2 - Permissible service pressure in bar or kpa: - Planned position of the NF mark on the radiator: - Paint coating and nature: 2 - TEST LABORATORY: The test laboratory can be one of the NF laboratories listed in Part 5 or a laboratory notified in accordance with the construction products regulation 305/2011/UE. Name and address of the laboratory: (<corporate name> <address>)

111 Certification Rules NF 047 Page 18 of SPECIAL CONDITIONS: - Radiators with grills, side plates and accessories If the equipment is sold with grills, side plates and accessories, it must undergo the tests together with these fittings. Indicate below whether your products have fittings by deleting as appropriate: yes no Selecting the tests (delete where appropriate): tests with and without fittings (grill and side plates) tests only with fittings - Connection of the radiator for the tests If the appliance is not designed to be connected in accordance with the specifications of the standard NF EN (see the edition of the standard in 9A-2) (connections on one side only, fluid inlet at the top and outlet and the base), then specify the type of connection below. Type of connection: (example: at the base, diagonally, etc.) - For tube radiators: Do the products have one or more baffles to force the water flow inside the appliances? YES NO (delete as appropriate)

112

113 Certification Rules NF 047 Page 20 of TECHNICAL CHARACTERISTICS: CHARACTERISTICS MODEL. MODEL. MODEL. MODEL. MODEL. MODEL. Reference or trade designation Overall height (mm) Distance between connections Centre-to-centre (mm) Water capacity (in litres/base element) Weight when empty (in kg/base element) Height of the fins (mm) Note: reproduce the table for any additional models. Height Height Height Height Centre- Centre- Centre- Centre- Pitch Pitch Pitch Pitch

114 Certification Rules NF 047 Page 21 of 28 FA-01b TECHNICAL DATA SHEET HORIZONTAL water flow radiators Example of products to which this data sheet applies Height Height Centre- Height Centre- Centre- Length Length Length Towel rail Radiators Panels Convectors Tube Vertical 1 - GENERAL INFORMATION: - Trade name. Trademark:. Trade range:. Trade designation:. Trade designation with fittings grill and side plates (if any):

115 Certification Rules NF 047 Page 22 of 28 - Production unit:. Company name:. Address: - Material(s):. Composition: (if different from the composition described in the standard NF EN 442 (see the edition of the standard in 9A-2). Specify the nature) - Depth "P1" of the emitter (in mm): - Overall depth "P2" (mm): P2 P1 P1+P2 P1+P2 P1+P2 - Permissible service pressure in bar or kpa: - Planned position of the NF mark on the radiator: - Paint coating and nature: 2 - TEST LABORATORY: The test laboratory can be one of the NF laboratories listed in Part 5 or a laboratory notified in accordance with the construction products regulation 305/2011/UE. Name and address of the laboratory: (<corporate name> <address>)

116 Certification Rules NF 047 Page 23 of SPECIAL CONDITIONS: - Radiators with grills, side plates and accessories If the equipment is sold with grills, side plates and accessories, it must undergo the tests together with these fittings. Indicate below whether your products have fittings by deleting as appropriate: yes no Selecting the tests (delete where appropriate): tests with and without fittings (grill and side plates) tests only with fittings - Connection of the radiator for the tests If the appliance is not designed to be connected in accordance with the specifications of the standard NF N (see the edition of the standard in 2.2) (connections on one side only, fluid inlet at the top and outlet and the base, or at the base for towel rails), then specify the type of connection below. Type of connection: (example: at the base, diagonally, etc.) - For tube radiators: Do the products have one or more baffles to force the water flow inside the appliances? YES NO (delete as appropriate) - Does the radiator have an injection tube? YES NO (delete as appropriate)

117 Certification Rules NF 047 Page 24 of TECHNICAL CHARACTERISTICS: Table to be completed when one height is available in several lengths: Example of radiators: Height Height Centre- Height Centre- Centre- Length Length Length MODEL. : Reference or trade designation: Height (in mm): Length (mm) Distance between connections Centre-to-centre (mm) Water capacity (in litres/base element) Weight when empty (in kg/base element) Note: reproduce the table as many times as necessary.

118 Certification Rules NF 047 Page 25 of Table to be completed when several heights are available for one reference length L = 1 m: Example of radiators: Height Centre- Length CHARACTERISTICS MODEL. MODEL. MODEL. MODEL. MODEL. MODEL. Reference or trade designation Overall height (mm) Distance between connections Centre-to-centre (mm) Water capacity (in litres/base element) Weight when empty (in kg/base element) Note: reproduce the table as many times as necessary.

119 Certification reference standard NF 047 Page 26 of 28 FA-02 INSTRUCTIONS FOR THE SUPPLY OF DRAWINGS (drawings must be supplied in two copies) * For all types of radiators/convectors/ceiling-mounted radiant panels: - One drawing per range or model, containing: the different detailed views and cross-sections required to define the appliance, with the various thicknesses and dimensions, with their tolerances, all the dimensions, with their tolerances, that impact the emission of heat (without forgetting the overall length and depths, the length and depth of the emitter, the height and the centre to centre distance), the main dimensions of other models (height) with their tolerances, presented in a table, the number, scale, name of the company and date, the product material (with the reference),. For panel radiators: A view of the fin panel, with details of the thickness, heights and pitch, with the tolerances, the number and position of the weld points for the panel and the fins, the drawing of the grill and side plates, with all the dimensions. * For extruded aluminium alloy radiators: a drawing of the head(s), with a cross-section and all the dimensions and tolerances, a cross-section of the section with the dimensions and tolerances. * For tube radiators: the position of the guide (where appropriate), the position and dimensions of the injection tube for each model (if any). a view of the fin panel, with details of the thickness, heights and pitch, with the tolerances, the position and number of the weld points for the fins, the drawing of the grill and side plates, with all the dimensions. * For convectors: A definition drawing of the fins with details, in particular, of the thickness, height and length and the tolerances, A definition drawing of the housing, with all the dimensions of the space requirements and the tolerances. a drawing of the grill with all the dimensions,

120 Certification reference standard NF 047 Page 27 of 28 FA-03 DECLARATION OF CONFORMITY I, the undersigned... acting in my capacity as: manager of the Ltd Company: (1)... Chairman of the Board of Directors; (1)... Company President 1 :... whose head office is located at:... Hereby declare that the products designated by: - the trademark:. - the trade name:... meet all of the European directives and national regulations in force applicable to the products. Moreover, I undertake to provide EUROVENT CERTITA Certification with any certificate or declaration it may ask of me. Date and signature of the legal representative of the applicant/holder (1) Delete as appropriate.

121 Certification reference standard NF 047 Page 28 of 28 9A-8. PROVISION ON DOCUMENTATION The general provisions applying to the markings on the documentation defined in paragraph of the rules apply to these products. The purpose of this paragraph is to define the additional requirements to be included in the holder's hardcopy or electronic documentation. The documentation must include at least the following information: the name and/or reference; the dimensions of the products (height, length, depth); the maximum operating pressure; the thermal output at the base element, or if it is not certified for each model;. the thermal output must be given at T 50K (75 C/65 C) and T 30K (55 C/45 C);. the type of connection used in the tests to determine the output must be specified, if the appliance is not designed to be connected in accordance with the connection mode defined in the standard NF EN 442 (see the edition of the standard in 9A-2).. if the appliances are certified with and without fittings (grill and/or side plates), the output must be entered in separate table to avoid any risk of misinterpretation;. If the thermal output was certified for the NF mark under special conditions that differ from those specified in the standard NF EN (see the edition of the standard in 9A-2), then they must be specified;. the following must be specified for convectors: - the reference flow rate (at T 50K); - the correction coefficients according to the flow rate, next to the output. the date of publication of the documentation. Additional information may also be provided, such as: the material; the gradient/exponent "n" of the characteristic equation of the range; head losses; the nominal flow rate. The holder is advised to send the draft documentation to EUROVENT CERTITA Certification for verification before printing and distributing.

122 PART 9 - APPENDIX B CERTIFICATION RULES Radiators, Convectors and Ceiling-mounted radiant panels, hot water heating, fan assisted and mixed SPECIFIC REQUIREMENTS FOR HOT WATER HEATING CEILING-MOUNTED RADIANT PANELS CONTENTS 9B-1 Scope 9B-2 Reference documents 9B-3 Definitions 9B-4 Technical specifications and characterisation methods 9B-5 Quality control specifications 9B-6 Specific test methods 9B-7 Certification application 9B-8 Provisions for the documentation Identification N : NF 047 Revision N : 14 Date of application: 12/12/2016

123 Certification Rules NF 047 Page 2 of 11 9B-1. SCOPE This part of the NF-047 rules the specific requirements applying to the ceiling-mounted radiant panels fed with hot water covered by the standard NF EN for their heating function. The certified characteristics are: The thermal output, The maximum operating pressure. 9B2. REFERENCE DOCUMENTS: The standards listed above take into account the mean standards but they are not exhaustive. The following standards are applicable to the products: NF EN : , free hanging heating and cooling surfaces for water with a temperature below 120 C. Pre-fabricated ceiling mounted radiant panels for space heating. Technical specifications and requirements NF EN : , free hanging heating and cooling surfaces for water with a temperature below 120 C. Pre-fabricated ceiling mounted radiant panels for space heating. Test method for thermal output NF EN : , free hanging heating and cooling surfaces for water with a temperature below 120 C. Prefabricated ceiling mounted radiant panels for space heating. Rating method and evaluation of radiant thermal output NF EN : , free hanging heating and cooling surfaces for water with a temperature below 120 C. Open or closed heated ceiling surfaces. Test method for thermal output 9B-3. DEFINITIONS The definition of the products and procedures can be found in the standard NF EN (parts 1 and 2).

124 Certification Rules NF 047 Page 3 of 11 9B-4. TECHNICAL SPECIFICATIONS AND CHARACTERISATION METHODS 9B-4.1 Determination of the output of the appliances The number of products is selected and the thermal output is determined according to the test methods defined in the standard NF EN If he so wishes, the applicant/holder can ask the laboratory to test a number of appliances that is higher than the number specified in the standard NF EN or the test procedure. If, in certain special cases, the selection method described in the standard NF EN cannot define them, then EUROVENT CERTITA Certification is free to choose the models, possibly together with one of the NF mark laboratories. 9B-5. QUALITY CONTROL SPECIFICATIONS The quality control provisions stated in part 2 of these rules apply to these products. The manufacturer shall also apply the following specific requirements: 9B-5.1. Inspection of the components and raw materials. The manufacturer shall inspect the components used to manufacture the appliances or take other measures necessary to guarantee the conformity of purchased products. Special attention shall be paid to the following parts: - tubes, - sheet metal, - insulating materials, - paint. It is advisable to ask the suppliers to produce an analysis certificate (for tubes and sheet metal, conformity with the standard NF EN 10204, paragraph 2.2) for the above-listed products.. The manufacturer shall check the thickness and exterior diameter of the tubes.. The manufacturer shall check the thickness and surface condition of steel coils (no rust). 9B-5.2 Inspections during production The manufacturer must perform at least the following inspections, in accordance with its own sampling plan.

125 Certification Rules NF 047 Page 4 of 11 Inspections shall be made whenever changes are made to the manufacturer program or at least once a day. List of inspections: Length of the tubes, Length of the radiant metal panel, Width of the radiant metal panel, Height of the edges on the sides, Distance between the tubes, Distance between the axes of the attachment points. 9B-5.3 Inspection of the attachment points The manufacturer shall proceed with strength tests in accordance with paragraph 5.4 "Attachment point" of the standard NF EN The frequency of the inspections shall be: - For the load test with three times the total weight of the panel, at least once a week, - For the load test with five times the total weight of the panel, at least once a month. 9B-5.4 Weld inspections The manufacturer must periodically take samples (at least once a day) to perform tests (destructive or nondestructive), defined according to a suitable method, on the tubes welded onto the radiant panel. 9B-5.5 Paint inspections Reaction to fire: When, according to paragraph of the standard NF EN , the paint or organic coatings must represent less than 1% by weight or volume of the product, the manufacturer shall periodically check (once a week), using appropriate means (any suitable means), that the products comply with the requirements applying to reaction to fire (NF EN , 5.12). The effectiveness of the device must be proven. 9B-6 SPECIFIC TEST METHODS The test methods to determine the thermal output defined in the standard NF EN shall apply.

126 Certification Rules NF 047 Page 5 of 11 9B-7 Certification application In addition to the general documents specified in Part 8, the applicant shall also supply the documents in the table below: DOCUMENTS TO BE SUPPLIED NUMBER OF COPIES A technical data sheet for the product range, as per the standard data sheet "FB-01" The manufacturing plan, in accordance with the instructions in FB- 02 Test reports and/or catalogue from a laboratory that:. possesses the NF mark,. is notified, as per regulation n 305/2011 (Construction products) Declaration of conformity FB-03 1 Photograph or commercial document (optional) 1 Minimum number and declaration of conformity and stability of the attachment points Report (approved by management) confirming that the sample was made with the same materials and processes as the standard production models (excluding the insulating materials)

127 Certification Rules NF 047 Page 6 of 11 FB-01 TECHNICAL DATA SHEET CEILING-MOUNTED RADIANT PANELS 1 - GENERAL INFORMATION: Trade name. Trademark:. Trade range:. Trade designation: - Production unit: - Material(s):. Company name:. Address: - Overall height (of the edges on the sides) in mm: - Overall width of one module in mm: - Number of tubes per module: - Distance between the tubes in mm: - Diameter of the tube in mm: Type of tube: Quality of the tube: - Maximum operating pressure in bar or kpa: - Paint coating and nature:

128 Certification Rules NF 047 Page 7 of 11 - Specification of the upper insulating material(s) (marketed): Nature and definition of the insulating material: Thermal resistance in m 2 k/w: Density at 40 C in kg/m 3 : Coating: Fire resistance: - Space provided for the NF mark on the radiant panel: 2 - TEST LABORATORY: The test laboratory can be one of the NF laboratories listed in Part 5 or a laboratory notified in accordance with the construction products directive regulation 305/2011/UE. Name and address of the laboratory: (<corporate name> <address>)

129 Certification Rules NF 047 Page 8 of TECHNICAL CHARACTERISTICS PER LINEAR METRE: CHARACTERISTICS MODEL. MODEL. MODEL. MODEL. MODEL. MODEL. Name Width (mm) Water capacity (l/ml) Weight when empty (kg/ml) Note: reproduce the table for any additional models.

130 Certification reference standard NF 047 Page 9 of 11 FB02 INSTRUCTIONS FOR THE SUPPLY OF DRAWINGS (drawings must be supplied in two copies) - One drawing per range or model, containing: the different detailed views and cross-sections required to define the appliance, with the various thicknesses and dimensions, with their tolerances, all the dimensions, with their tolerances, that impact the emission of heat (without forgetting the overall length and depths, the length and depth of the emitter, the height and the centre to centre distance), the main dimensions of other models (height) with their tolerances, presented in a table, the number, scale, name of the company and date, the product material (with the reference), details of the welds and other assembly methods. The number of connection points between the dry surface and the humid surface by metre and by tube. details of the materials used, and in particular the diameter of the tube, the nominal thickness of the walls of the humid and dry surfaces, the specification of the surface treatment, the maximum distance between the axes of the attachment points, the method used to connect the dry surface to the humid surface.

131 Certification reference standard NF 047 Page 10 of 11 FB-03 DECLARATION OF CONFORMITY I, the undersigned... acting in my capacity as: manager of the Ltd Company: (1)... Chairman of the Board of Directors; (1)... Company President 1 :... whose head office is located at:... Hereby declare that the products designated by: - the trademark:. - the trade name:... meet all of the European directives and national regulations in force applicable to the products. Moreover, I undertake to provide EUROVENT CERTITA Certification with any certificate or declaration it may ask of me. Date and signature of the legal representative of the applicant/holder (1) Delete as appropriate.

132 Certification reference standard NF 047 Page 11 of 11 9B-8. PROVISION ON DOCUMENTATION The general provisions applying to the markings on the documentation defined in paragraph of the rules apply to these products. The purpose of this paragraph is to define the additional requirements to be included in the holder's hardcopy or electronic documentation. The documentation must include at least the following information: the name and/or reference; the dimensions of the products (height, length, depth); the maximum operating pressure; the thermal output of the basic element at T 55K; the date of publication of the documentation. Additional information may also be provided, such as: the material; the gradient/exponent "n" of the characteristic equation of the range; head losses. The holder is advised to send the draft documentation to EUROVENT CERTITA Certification for verification before printing and distributing.

133 PART 9 - APPENDIX C CERTIFICATION RULES Radiators, Convectors and Ceiling-mounted radiant panels, hot water heating, fan assisted and mixed SPECIFIC REQUIREMENTS FOR FAN-ASSISTED RADIATORS AND CONVECTORS CONTENTS 9C-1 Scope 9C-2 Reference documents 9C-3 Definitions 9C-4 Technical specifications and characterisation methods 9C-5 Quality control specifications 9C-6 Specific test methods 9C-7 Certification file 9C-8 Provision on documentation Identification N : NF 047 Revision N : 14 Date of application: 12/12/2016

134 Certification Rules NF 047 Page 2 of 14 9C-1. SCOPE This appendix of the NF-047 Rules defines the specific requirements for appliances assisted by fans that use water for their heating function. The appendix applies to fan-assisted radiators and convectors. These rules do not apply any thermal output limits for the certification of products. The thermal output of products that is below or above those defined in the standard NF EN 442 (see the edition of the standard in 9C-2) for the execution of tests is determined by calculation. The certification does not apply to fan-assisted appliances fed with air from outside the building and trench convectors. The certified characteristics are: The thermal output of the fan when working and at a standstill, The maximum operating pressure, The acoustic power level. For the electric part: The standby power, The power when in operation. 9C-2. REFERENCE DOCUMENTS: The standards listed above take into account the mean standards but they are not exhaustive. The following standards are applicable to the products: NF EN : 2015, Fan assisted radiators, convectors and trench convectors. Technical specifications and requirements NF EN : 2015, Fan assisted radiators, convectors and trench convectors. Test method and rating for thermal output NF EN 442-1: , Radiators and convectors - Part 1: technical specifications and requirements. NF EN 442-2: , Radiators and convectors Part 2: test methods and rating. NF EN : 2005 (+A1: A2: 2009), Household and similar electrical appliances - Part 2-40: special rules for heat pumps, air conditioners and dehumidifiers. NF EN 50106: 2009, Safety of household and similar electrical appliances Particular rules for routine tests referring to appliances under the scope of the standard EN

135 Certification Rules NF 047 Page 3 of 14 NF EN ISO 3744: 2012, 2012, Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane. NF EN ISO 3745: 2009, Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Precision methods for anechoic and hemi-anechoic rooms. 9C-3. DEFINITIONS Definition of the products is done in the standards NF EN 442 (part 1 and 2) and NF EN (see the edition of the standards in 9C-2). A range of fan-assisted appliances: A range is made up of: - a range of appliances, as defined in paragraph 3 of the standard NF EN (see the edition of the standard in 9C-2), - the same fan type. 9C-4. TECHNICAL SPECIFICATIONS AND CHARACTERISATION METHODS 9C-4.1. Determining the output: The thermal outputs are measured according to the test methods defined in the standard NF EN (see the edition of the standard in 9C-2). The outputs are determined with the fan at a standstill and working. The values in the test report are the certified values. No tolerance is allowed for the declared outputs. When monitoring the product, the permissible tolerance between the certified output and the measured output is -4%. The number of products to be tested is determined according to the criteria defined in the standard NF EN (see the edition of the standard in 9C-2). The output of panel radiators is determined with the appliances fitted at least with their grill and side plates, if this version exists in the applicant's / holder's catalogue. For "ON / OFF" all-or-nothing fans, the measurement is made at the fan's nominal speed. For fans with variable or adjustable speeds, the measurement is made at the fan's minimum and maximum speeds, and at the intermediate speed (where appropriate), as indicated by the applicant in the application for the right to use the NF mark.

136 Certification Rules NF 047 Page 4 of 14 Conditions for the determination of the outputs: - the thermal output is measured at T 50K and calculated at T 30K, even if a range of appliances is not designed for use at T 50K. These two outputs are certified. 9C-4.2. Mechanical resistance tests and deformation measurements: For panel and plate radiators and radiators made of flat tubes, each selected sample is tested to measure the output in accordance with paragraph 9A-4.2 of part 10 appendix A. Conformity is confirmed if the appliance does not leak and is deformed by less than 10% after the test. 9C-4.3. Absorbed electric power: There are three types of variation of ventilation speeds: - all-or-nothing, "On / Off", - speed variation by the supply voltage, - several pre-set speeds selected using a switch. The certified powers are determined at the minimum, intermediate and maximum speeds. The measurements are given with two figures after the decimal point, applying the following rounding rules: - between 0.01 and 0.04, rounded down to the next hundredth, - between 0.05 and 0.09, rounded up to the next hundredth. Evaluation of the conformity of the declared values: Conformity is confirmed if the measured value is not 5% greater than the value included in the applicant's application for the right to use the NF mark. There are two possible cases of non-conformity: - Only one declared value is observed and does not comply with the measured value. This value is corrected and the measured value is retained. - Several declared values do not comply with the measured values. The correction is made as follows: The declared values found to be non-compliant with the measured values are corrected, and the measured values are retained. The declared values that do not correspond to the tested appliances are corrected by increasing them by the mean of the differences between the valued measurements and the non-compliant declared values. Example of min and max outputs: Before correction Model N 1 N 2 N 3 N 4 Output min max min max min max min max Declared output Measured output Difference (%) Mean difference = ( )/3 = 6.17%

137 Certification Rules NF 047 Page 5 of 14 After correction Model N 1 N 2 N 3 N 4 Output min max min max min max min max Declared output Corrected output Example: 2.1 x 6.17%=2.24 W 9C-4.4. Standby power: The standby power is measured when the appliance is switched on and the fan(s) at a standstill. Conformity is confirmed if the measured value is not 5% greater than the value included in the applicant's application for the right to use the NF mark. If the value is declared to be non-compliant with the measured value, it is returned to the measured value by correcting the applicable tolerance (defined previously). 9C-4.5. Electrical safety: To obtain the right to use the NF mark, appliances fitted with fans must meet the requirements of the standard NF EN (see the edition of the standard in 9C-2). 9C-4.6. Sound power Three situations are possible: - all-or-nothing, "On / Off" fan: The certified value is the value declared by the applicant when the fan is in nominal operation. - Variable speed fan: The certified values are the values declared by the applicant when the fan is operating at minimum, intermediate and maximum speed. - Multiple speed fan (adjustable): The certified values are the values declared by the applicant at each speed. Sound power must be determined according to one of the standards mentioned in paragraph 9C-2. Measurements must be made at least according to class 2. The measured values are included in the test report of the individual units. The following rounding rule is applied: between 0.1 and 0.4, round down to the next unit. Between 0.5 and 0.9, round up to the next unit. The appliances from the range used to determine the thermal outputs will be tested. Configuration: For radiators / convectors, the appliance to be tested must be installed according to the test protocol described in paragraph 9C-6.

138 Certification Rules NF 047 Page 6 of 14 When taking measurements in the open air, as per the standard NF EN ISO 3744 or NF EN ISO 3745 (see the editions of the standards in 9C-2), a supporting wall with the following characteristics must be installed: the density must be > 15 kg/m 2 (e.g., bonded sandwich type plasterboard), 2.50 m high, 4.60 m long (corresponding to one half of the wavelength at the lowest frequency to be measured). The acoustic test shall be conducted at temperatures of between 15 C and 25 C, without connecting the appliance, with no water inside the appliance and with a dry coil surface. Evaluation of the conformity of the declared values: Conformity is confirmed if the measured value is not 2 db(a) greater than the value included in the applicant's application for the right to use the NF mark. There are two possible cases of non-conformity: - Only one declared value is observed and does not comply with the measured value. This value is corrected and the measured value is retained. - Several declared values do not comply with the measured values. The correction is made as follows: The declared values found to be non-compliant with the measured values are corrected, and the measured values are retained. The declared values that do not correspond to the tested appliances are corrected by increasing them by the mean of the differences between the valued measurements and the non-compliant declared values. Example: Before correction Model N 1 N 2 N 3 N 4 Output min max min max min max min max Declared output Measured output Difference Mean difference = (3+3+4)/3 = 3.3, or a correction value returned to the unit of 3. After correction Model N 1 N 2 N 3 N 4 Output min max min max min max min max Declared output Corrected output C-5. QUALITY CONTROL SPECIFICATIONS The quality control provisions stated in part 2 and in part 9 appendix A of these rules apply to these products. The manufacturer shall also implement:

139 Certification Rules NF 047 Page 7 of 14 Acceptance checks: The output of fans must be checked according to the manufacturer's sampling plan, in addition to the documentary check. Inspections on the finished product: Earth continuity and dielectric rigidity tests must be performed on every finished product according to the standard NF EN (see the edition of the standard in 9C-2). 9C-6. TEST METHODS The nominal (standard) thermal output is determined according to the standard NF EN (see the edition of the standard in 9C-2). 9C-6.1. Determining the thermal output 9C Radiators and convectors in static mode The nominal thermal heat output (standard) is determined according to the standard NF EN (see the edition of the standard in 9A-2). 9C Fan-assisted radiators and convectors The determination of the thermal heat output and the requirements on the devices measure are described in the standard NF EN (see the edition of the standard in 9C-2). 9C-7. CERTIFICATION FILE In addition to the general documents specified in Part 8, the applicant shall also supply the documents in the table below: DOCUMENTS TO BE SUPPLIED NUMBER OF COPIES A technical data sheet for the product range, as per the standard data sheet FC-01 The manufacturing plan, in accordance with the instructions in FC- 02 Electric wiring diagram 2 Test report(s) and/or catalogue to determine the outputs 1 Declaration of conformity - FC-03 1 User manual 1 Photograph or commercial document (optional) 1 1 2

140 Certification Rules NF 047 Page 8 of 14 FC-01 TECHNICAL DATA SHEET VERTICAL water flow radiators 1 - GENERAL INFORMATION: - Trade name. Trademark:. Trade range:. Trade designation:. Trade designation with fittings grill and side plates (if any): - Production unit: - Material(s):. Company name:. Address: - Length of the basic module in mm (see definition in 9C-3): - Overall depth (mm): - Permissible operating pressure in bar or kpa: - Planned position of the NF mark on the radiator: - Paint coating and nature:

141 Certification Rules NF 047 Page 9 of 14 - Fan:. Type: Rotary (centrifugal) Propeller. Brand: Diameter of the blades (in mm):. Supply voltage and frequency:. Multiple-speed fans: by switch:. number of positions:. declaration of the intermediate position for the test:. declaration of the voltage in the minimum, intermediate (for the test) and maximum positions: by variable speed:. declaration of the voltage for the tests at: - Minimum speed: - Intermediate speed: - Maximum speed: 2 - TEST LABORATORY: The test laboratory must be one of the NF mark laboratories listed in part 5. Name of the laboratory: <corporate name> 3 - SPECIAL CONDITIONS: - Radiators with grills, side plates and accessories If the equipment is sold with grills, side plates and accessories, it must undergo the tests together with these fittings. Indicate below whether your products have fittings by deleting as appropriate: yes no Selecting the tests (delete where appropriate): tests with and without fittings (grill and side plates) tests only with fittings

142 Certification Rules NF 047 Page 10 of 14 - Connection of the radiator for the tests If the appliance cannot be connected in accordance with the specifications of the standard NF EN (see the edition of the standard in 9C-2) paragraph (connections on one side only, fluid inlet at the top and outlet and the base), then specify the type of connection below. Type of connection: (example: at the base, diagonally, etc.) - For tube radiators: Do the products have one or more guides to force the water flow inside the appliances? YES NO (delete as appropriate) 4 - TECHNICAL CHARACTERISTICS: Declaration of the acoustic power and electric output versus the number of fans - Declared standby output (in Watts to the nearest 10 th ):.. - Table for ON-OFF type operation: N of fans Length of the appliance (mm) Sound power (db(a)) (1) Absorbed power (in Watts) 2) (1) values in units (2) values to the 100 th Note: reproduce the table as many times as necessary.

143 Certification Rules NF 047 Page 11 of 14 - Table for variable-speed type operation: N of fans Length of the appliance (mm) Sound power in db(a) (1) At the speed: Absorbed electric power (Watts) (2) At the speed: minimum intermediate maximum minimum intermediate maximum (1) values in units (2) values to the 100 th Note: reproduce the table as many times as necessary. 4.2 Other characteristics Height (in mm):. Reference Length (mm) Distance between connections Centre-to-centre (mm) Water capacity (in litres/base element) Weight when empty (in kg/base element) Height of the convection fins (mm) Note: reproduce the table as many times as necessary.

144 Certification Rules NF 047 Page 12 of 14 FC-02 INSTRUCTIONS FOR THE SUPPLY OF DRAWINGS (drawings must be supplied in two copies) * For all types of radiators/convectors/ceiling-mounted radiant panels: - One drawing per range or model, containing: the different detailed views and cross-sections required to define the appliance, with the various thicknesses and dimensions, with their tolerances, position of the fans, all the dimensions, with their tolerances, that impact the emission of heat (without forgetting the overall length and depths, the length and depth of the emitter, the height and the centre to centre distance), the main dimensions of other models (height) with their tolerances, presented in a table, the number, scale, name of the company and date, the product material (with the reference),. For panel radiators: A view of the fin panel, with details of the thickness, heights and pitch, with the tolerances, the number and position of the weld points for the panel and the fins, the drawing of the grill and side plates, with all the dimensions. * For extruded aluminium alloy radiators: a drawing of the head(s), with a cross-section and all the dimensions and tolerances, a cross-section of the section with the dimensions and tolerances. * For tube radiators: the position of the guide (where appropriate), the position and dimensions of the injection tube for each model (if any). a view of the fin panel, with details of the thickness, heights and pitch, with the tolerances, the position and number of the weld points for the fins, the drawing of the grill and side plates, with all the dimensions. * For convectors: A definition drawing of the fins with details, in particular, of the thickness, height and length and the tolerances, A definition drawing of the housing, with all the dimensions of the space requirements and the tolerances. a drawing of the grill with all the dimensions,

145 Certification Rules NF 047 Page 13 of 14 FC-03 DECLARATION OF CONFORMITY I, the undersigned... acting in my capacity as: manager of the Ltd Company: (1)... Chairman of the Board of Directors; (1)... Company President 1 :... whose head office is located at:... Hereby declare that the products designated by: - the trademark:. - the trade name:... meet all of the European directives and national regulations in force applicable to the products. Moreover, I undertake to provide EUROVENT CERTITA Certification with any certificate or declaration it may ask of me. Date and signature of the legal representative of the applicant/holder (1) Delete as appropriate.

146 Certification Rules NF 047 Page 14 of 14 9C-8. PROVISION ON DOCUMENTATION The general provisions applying to the markings on the documentation defined in paragraph of the rules apply to these products. The purpose of this paragraph is to define the additional requirements to be included in the holder's hardcopy or electronic documentation. The documentation must meet the regulatory and normative requirements relating to electrical safety. The documentation must also include at least the following information: the name and/or reference; the dimensions of the radiators (height, length, depth); the maximum operating pressure; the thermal output with:. the fans at a standstill,. the fans in operation (minimum, intermediate, maximum and others, if adjustable), The thermal outputs must be given at T 50K (75 C/65 C) and T 30K (55 C/45 C). However, if the range is designed to work at T 50K, then the outputs at this T can be indicated in the documentation, but the holder must indicate the output at the maximum operating T of the appliances. The following must be specified for convectors: - the reference flow rate (at T 50K); - the correction coefficients according to the flow rate, next to the output. The type of connection used in the tests to determine the output must be specified, if the appliance is not designed to be connected in accordance with the connection mode defined in the standard NF EN 442 (see the edition of the standard in 9C-2.2). the sound powers with:. the fans in operation (minimum, intermediate, maximum and others, if adjustable), the standby electric output; the absorbed electric power when operating at minimum, intermediate and maximum speeds, and at other speeds, if adjustable; the date of publication of the documentation. Additional information may also be provided, such as: the material; the gradient/exponent "n" of the characteristic equation of the range; head losses; the nominal water flow.

147 PART 9 APPENDIX D CERTIFICATION RULES Radiators, Convectors and Ceiling-mounted radiant panels, hot water heating, fan assisted and mixed SPECIFIC REQUIREMENTS FOR MIXED RADIATORS CONTENTS 9D-1 Scope 9D-2 Reference documents 9D-3 Definitions 9D-4 Technical specifications and characterisation methods 9D-5 Quality control specifications 9D-6 Specific test methods 9D-7 Certification application 9D-8 Provisions for the documentation Identification N : NF 047 Revision N : 14 Date of application: 12/12/2016

148 Certification Rules NF 047 Page 2 of 13 9D-1. SCOPE This appendix of the NF-047 Rules describes the specific requirements applying to mixed appliances that use hot water and electricity, in which hot water is the main energy source and electricity is used as an auxiliary source, in particular between seasons. To benefit from the right to use the NF mark, mixed radiators shall: - benefit from the right to use the NF Radiators, Convectors and Ceiling-mounted radiant panels, hot water heating, fan assisted and mixed mark for their heating function by hot water, - be fitted with a regulation system that stops the electric heating resistance, either by a timing device and/or by the regulation of the ambient temperature or the temperature of the water, - meet the requirements of the standard NF EN and/or NF EN (see the editions of the standards in 9D-2), - be assembled in the factory. The installation of the auxiliary electric heating at a later date is forbidden, - be fitted with a temperature limiter (electric circuit breaker) in the event of abnormal use. The certified characteristics are: the surface temperature of mixed radiators with an electric heating resistance, the air outlet temperature for mixed radiators with a blower, the output of the electric heating element and/or of the blower. 9D-2. REFERENCE DOCUMENTS: The standards listed above take into account the mean standards but they are not exhaustive. The following standards are applicable to the products: NF EN : , Radiators and convectors - Part 1: technical specifications and requirements. NF EN 442-2: , Radiators and convectors Part 2: test methods and rating. NF EN : 2013 (A11: 2014), Household and similar electrical appliances. Safety. General requirements NF EN : 2012 (+A11: 2013), Household and similar electrical appliances - Part 2-30: particular requirements for room heaters. NF EN : 2005 (+A1: 2006, +A2: 2008), Household and similar electrical appliances - Part 2-43: particular requirements for clothes dryers and towel rails. NF EN 50106: 2009, Safety of household and similar electrical appliances Particular rules for routine tests referring to appliances under the scope of the standard NF EN D-3. DEFINITIONS Radiator See the definition in paragraph 3 of the standard NF EN (see the edition of the standard in 9D-2).

149 Certification Rules NF 047 Page 3 of 13 Radiator and towel rails without blower Comprises a hot water central heating radiator, an electric heating element and a regulation system. The immersed electric heating element is mounted inside the radiator in direct contact with the central heating circuit. Mixed radiator and towel rails with blower Comprises a hot water central heating radiator, an electric blower and a regulation system. The blower is attached to the radiator and cannot be detached. Product range The product range is made up of: - a range of appliances, as defined in paragraph 3 of the standard NF EN (see the edition of the standard in 9D-2), - the same electric heating element or blower technology, - the same regulation system of the auxiliary electric heating. 9D-4. TECHNICAL SPECIFICATIONS AND CHARACTERISATION METHODS 9D-4.1 Electrical safety of mixed radiators: The radiator shall meet the requirements of the standard NF EN and/or NF EN (see the editions of the standards in 9D-2). For the radiators and towel rails with electric heating element, it is accepted that the tests are realized with a product filled with water and closed by the manufacturer. Otherwise, the specifications described above have to be followed. Specification for mixed radiators and towel rails with an electric heating resistance: The appliance shall be tested in accordance with the instructions for installation and use described in the manufacturer's manual. The radiator shall be installed under the following conditions for the surface temperature tests: The inlet of the radiator is connected to a water supply, as shown in the diagram below (any other equivalent arrangement may also be considered). The stop device on the size of water tank shall remain open during the tests and the second stop device (4b) shall be closed to prevent the water from escaping. It is necessary to check the radiator and the supply circuit for air bubbles when filling the radiator with water. (5) (2) (1) (3) (1) mixed radiator (2) water tank (3) feed pipe (4a and 4b) stop device (5) drain (4b) (4a)

150 Certification Rules NF 047 Page 4 of 13 9D-4.2. Determining the surface temperature Mixed towel rails radiators with blower: The test is performed in accordance with the specifications of the standard NF EN (covering the radiator with four layers of linen, Pn à 1,15) (see the edition of the standard in 9D-2). The measured surface temperature shall not exceed 75 K, i.e., in a room at 20 C, a maximum temperature of 95 C Mixed radiators without blower: The test is performed in accordance with the specifications of the standard NF EN (see the edition of the standard in 9D-2). The measured surface temperature shall not exceed 70 K, i.e., in a room at 20 C, a maximum temperature of 90 C Mixed radiators with blower (without an electric heating resistance): If the towel rail has a blower, the test in accordance with NF EN (see the edition of the standard in 9D-2) shall be realized. The maximum measured temperature on the surface of the grill of the outlet air shall not exceed 100 K, i.e., in a room at 20 C, a maximum temperature of 120 C. 9D-4.3. Abnormal functioning condition for mixed radiators with a heating resistance: The test consists in checking the operation of the thermal protection device when air is accumulated inside the radiator, possibly causing the electric heating resistance to emerge from the water. Two radiators of smaller dimensions of the range are tested having in one hand a resistance of the lowest power and in the other hand a resistance of the biggest power. The temperature of the appliance is measured by covering it with a felt. Safety element has to cut before the surface temperature of the radiator achieves 100K, either for a room at 20 C a maximal temperature at 120 C. If the safety element failed, the ultimate protection has to act before the surface temperature of the radiator achieves 150 K, either for a room at 20 C a maximal temperature at 170 C. The laboratory shall make sure that the interior of the radiator is dry in order to prevent the formation of steam in the course of the test. 9D-4.4. Determining the power of the electric heating resistance: Conformity is confirmed if the measured value is not 5% greater or 10% less than the value included in the applicant's application for the right to use the NF mark. For the radiators and towel rail radiators fitted with an electric heating resistance and a blower, the power of each ensemble is measured separately. Nota: take into account electronic power and power of the turbine or fan.

151 Certification Rules NF 047 Page 5 of 13 9D-4.5. Pressure resistance test: The test is performed on a finished product from the range at a pressure at least at 1.69 times the appliance's maximum operative pressure (Pmax) declared by the applicant/holder. The appliance is compliant if the radiator does not leak. The test can be made using water or air inside the appliance. The pressure needs to be maintained in the appliance during 2 minutes and checked by using a manometer having accuracy of ±5%. 9D-4.6. Tests: The table below explains the various tests performed for admission to the NF mark and for monitoring purposes. Process NF EN (2-30 and/or 2-43) Surface temperature Abnormal operating conditions Electric output Pressure resistance test Admission X X X X X Monitoring X X X X 9D-5. QUALITY CONTROL SPECIFICATIONS 9D-5.1 Requirements for mixed radiators with an electric heating resistance Acceptance checks: The manufacturer shall be capable of demonstrating the conformity of the electric heating resistances with the standard NF EN (see the edition of the standard in 9D-2). In addition to the documentation check, the output of the electric heating resistances shall be checked in accordance with the sampling plan described by the manufacturer. Tightening torque checks The tightening torque shall be checked in accordance with the manufacturer's inspection plan. The checks shall be performed at least once a day, or once per production run. Pressure resistance test: The manufacturer shall perform pressure resistance tests in accordance with the specification described in the preceding paragraph 9D-4.6. The samples shall be taken at least once a week, or once per production run.

152 Certification Rules NF 047 Page 6 of 13 Inspections on the finished product: Unit tests shall be performed in order to check the conformity of the following aspects of the appliances: - continuity of the earth (for class I appliances) - the dielectric rigidity (for class I or II appliances), as defined in the standard NF EN (see the edition of the standard in 9D-2), - electric power. 9D-5.2 Requirements for mixed radiators with blowers Acceptance checks: The manufacturer must be capable of demonstrating the conformity of the blowers with the standard NF EN (see the edition of the standard in 9D-2). In addition to the documentation check, the output of the blowers shall be checked in accordance with the sampling plan described by the manufacturer. Inspections on the finished product: Unit tests shall be performed in order to check the conformity of the following aspects of the appliances: - continuity of the earth (for class I radiators) and the dielectric rigidity, as defined in the standard NF EN (for class I or II appliances) (see the edition of the standard in 9D-2), - electric power. 9D-6. SPECIFIC TEST METHODS Since the standards NF EN and NF EN (see the editions of the standards in 9D-2) do not cover mixed radiators, the installation specifications of the radiators are defined in paragraph 9D-4.1. These standards apply to the tests and conformity checks of the appliances.

153 Certification Rules NF 047 Page 7 of 13 9D-7. CERTIFICATION APPLICATION In addition to the general documents specified in Part 8, the applicant shall also supply the documents in the table below: DOCUMENTS TO BE SUPPLIED A technical data sheet for the product range, as per the standard data sheet "FD-01". The manufacturing plan, in accordance with the instructions in FD- 02. NUMBER OF COPIES 1 2 From accredited laboratory:. A test report of an appliance in the range according to the standard NF EN and/or NF EN (see the editions of the standards in 9D-2) of the range corresponding to the application,. a test report for each electric output in the range (heating resistance and/or blower). From NF-047 laboratory:. A test report for abnormal condition functioning of an appliance in the range (see 9D-4.3); a test report for the strength pressure test, of an appliance in the range (see 9D-4.5). Declaration of conformity FD-03 1 User manual 1 Photograph or commercial document (optional). 1 1

154 Certification Rules NF 047 Page 8 of 13 FD-01 TECHNICAL DATA SHEET 1- Reference of the hot water range admitted to the NF mark:. Trademark:. Trade designation:. Registration number:. Certificate number:. Certificate date: Note: EUROVENT CERTITA Certification must be informed of any changes that could affect the certification of this range. 2 - General information: - Trade name:. Trademark:. Trade range:. Trade designation: - Production unit:. Company name:. Address: - Overall depth (mm): - Material(s): - Product protection class: - Product supply voltage and frequency: - Planned position of the NF mark on the radiator: 3- NF mark test laboratory: Laboratory name: <corporate name>

155

156 Certification Rules NF 047 Page 10 of technical characteristics: CHARACTERISTICS MODEL. MODEL. MODEL. MODEL. MODEL. MODEL. Reference / name Overall height (mm) Distance between connection Centre-to-centre (mm) Water capacity (litres) Weight when empty (kg) Height of the fins (mm) Brand Reference Declared power of the heating resistance (Watts) Declared power of the blower (Watts) Height of the electric heating resistance (mm) Type of regulation (according to temperature: ambient or of the fluid) Note: reproduce the table for any additional models. Heating resistance and/or blower

157 Certification reference standard NF 047 Page 11 of 13 FD-02 INSTRUCTIONS FOR THE SUPPLY OF DRAWINGS (drawings must be supplied in two copies) * For all types of radiators: - One drawing per range or model, containing: the various detailed views and cross-sections required to define the appliance with an electric heating resistance or a blower, the main dimensions with their tolerances, the number, scale, name of the company and date, the product material (with the reference), * For panel radiators: the drawing of the grill and side plates, with all the dimensions, * For tube radiators: the position of the guide (where appropriate), the drawing of the grill and side plates, with all the dimensions,

158 Certification reference standard NF 047 Page 12 of 13 FD-03 DECLARATION OF CONFORMITY I, the undersigned... acting in my capacity as: manager of the Ltd Company: (1)... Chairman of the Board of Directors; (1)... Company President 1 :... whose head office is located at:... Hereby declare that the products designated by: - the trademark:. - the trade name:... meet all of the European directives and national regulations in force applicable to the products. Moreover, I undertake to provide EUROVENT CERTITA Certification with any certificate or declaration it may ask of me. Date and signature of the legal representative of the applicant/holder (1) Delete as appropriate.

159 Certification reference standard NF 047 Page 13 of 13 9D-8. PROVISION ON DOCUMENTATION The general provisions applying to the markings on the documentation defined in paragraph of the rules apply to these products. The purpose of this paragraph is to define the additional requirements to be included in the holder's hardcopy or electronic documentation. The documentation shall meet the regulatory and normative requirements applying to electrical safety. It shall also include at least the following information: the name and/or reference; the dimensions of the radiators (height, length, depth); the certified electric powers; the date of publication of the documentation. The holder is advised to send the draft documentation to EUROVENT CERTITA Certification for verification before printing and distributing. User manual supplied with the appliance: The following text shall appear on the manual: When using the "electric function" of the mixed radiator, only close the inlet tap and NEVER CLOSE THE RETURN in order to allow the fluid to expand towards the system. CAUTION: closing the return can result in the destruction of the heating unit due to overpressure higher than the operating pressure. If the central heating system is fitted with a pump that is independent of the boiler, then it must be stopped. Otherwise there is a danger that the heating unit will be siphoned if the joins are not perfectly tight.

160 Règles générales de la marque NF General rules of the NF mark Révision 6. Approuvée par le Président d AFNOR, le 23/04/2012 Revision 6. Approved by the President of AFNOR, on 23/04/ rue Francis de Pressensé La Plaine Saint-Denis Cedex - France -T. +33 (0) F : +33 (0) SAS au capital de euros RCS Bobigny

161 Sommaire 1. Objet Propriété de la marque NF Organisation générale Conditions d usage Référentiels de certification Comité de la marque NF Accords de reconnaissance de marques Confidentialité, protection des documents Information sur les produits bénéficiant de la marque NF et promotion de la marque NF Suspension, retrait du droit d usage Contestation et appel Validité du droit d usage de la marque NF Usage abusif de la marque NF Régime financier Suppression d une application de la marque NF Approbation par le Président d AFNOR... 9 Contents 1 - Subject Ownership of the NF mark General organisation Conditions of use Certification Guidelines NF Mark Committee Markrecognition agreements Confidentiality, safeguarding of documents Information on products benefiting from the NF mark, and promotion of the NF mark Suspension, withdrawal of user rights Dispute and Appeals Validity of the right to use the NF mark Misuse of the NF mark Financial framework Discontinuance of an NF mark application Approval by the President of AFNOR... 9 Règles générales de la marque NF General rules of the NF mark 2/9

162 1. Objet La marque collective de certification NF n , matérialise une certification de produits au sens de l article L du code de la consommation (1). Une certification matérialisée par la marque NF a pour objet d attester la conformité des produits aux documents normatifs nationaux, européens et internationaux les concernant, tels que des normes ou des spécifications techniques, dans des conditions définies par des Référentiels de certification (2). Pour le contrôle des produits, la certification matérialisée par la marque NF peut s appuyer sur tout ou partie des dispositions des documents normatifs nationaux, européens et internationaux, en vigueur en matière de management de la qualité. La certification matérialisée par la marque NF peut s appliquer à tout produit et éventuellement à des prestations de service associées à ces produits. Le terme produit couvre les produits et les prestations de services éventuellement associées dans la suite des présentes règles. 1 - Subject The NF n collective certification mark is a system of product certification within the meaning of Article L of the Consumption Code (1). The aim of NF mark certification is to attest to a product's compliance with the national, European and international regulatory documents concerning it, such as technical standards or specifications, under conditions defined by the Certification Guidelines (2). With regard to product testing, NF mark certification can be based on some or all of the provisions of the national, European and international regulatory documents in force with regard to quality management. NF mark certification can be applied to any product and possibly to the provision of services associated with these products. The term product covers the products themselves, along with the provision of services which may be associated with them, in accordance with the following rules. 2. Propriété de la marque NF La marque NF n est la propriété exclusive d AFNOR, en vertu du dépôt à titre de marque effectué le 23 juillet La marque NF fait également l objet d enregistrements internationaux et nationaux dans les pays où il a été nécessaire d assurer sa protection. La marque NF est une marque collective de certification qui en tant que telle n est cessible que dans les conditions particulières fixées par la loi et est insaisissable. Elle ne peut faire l objet d aucune mesure d exécution forcée. 2 - Ownership of the NF mark The NF n mark is the exclusive property of AFNOR, by virtue of the trademark registration submitted on 23 July The NF mark has also been registered internationally and nationally in the countries in which its protection must be guaranteed. The NF mark is a collective certification mark and, as such, is transferable only in the special conditions set by law, and is unattachable. It cannot be the subject of any compulsory enforcement measures. 3. Organisation générale AFNOR a concédé à AFNOR Certification, SASU, une licence d exploitation de la marque NF. AFNOR Certification gère le système de certification NF, qui définit notamment les règles de gouvernance et les modalités de fonctionnement de la marque NF. 3 - General organisation AFNOR has granted AFNOR Certification, SASU, an operating licence for the NF mark. AFNOR Certification manages the NF certification system, which defines the governance rules and operating procedures for the NF mark. (1) Modifié par la loi n du 4 août 2008 de modernisation de l économie. Modified by Law No of 4 August 2008 related to the modernization of the economy. (2) Le terme «règles de certification» peut également être employé. The term certification rules may also be used. Règles générales de la marque NF General rules of the NF mark 3/9

CERTIFICATION RULES OF THE MARK

CERTIFICATION RULES OF THE MARK Certification body mandated by AFNOR Certification 48/50 rue de la Victoire 75009 PARIS Telephone : +33 (0)1 75 44 71 71 www.eurovent-certification.com /www.certita.fr CERTIFICATION RULES OF THE MARK RADIATORS,

More information

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU GNB-CPR AG Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU NB-CPR/AG/03/002r3 Issued: 24 May 2013 APPROVED GUIDANCE GNB-CPR AG position paper Guidance to

More information

Kiwa Regulations for Certification in accordance with the CPR

Kiwa Regulations for Certification in accordance with the CPR 1 May 2014 Kiwa Regulations for Certification in accordance with the CPR EC Regulation No. 305/2011 (CPR) 1 May 2014 Kiwa Regulations for Certification in accordance with the CPR EC Regulation No. 305/2011

More information

Chief Operating Officer Giampiero Belcredi

Chief Operating Officer Giampiero Belcredi CONTENTS 1. PURPOSE AND SCOPE 2. GENERAL PRINCIPLES AND GUARANTEES FOR THE CLIENT 3. ACCESS REQUIREMENTS FOR CERTIFICATION 4. ASSESSMENT PROCESS REQUIREMENTS 5. SUSPENSION AND REVOCATION OF THE CERTIFICATION

More information

Centexbel. General certification regulations. Construction products

Centexbel. General certification regulations. Construction products Centexbel Scientific and Technical centre of the Belgian Textile Industry General certification regulations Construction products 22/03/17 blz. 1 / 8 Contents 1 Introduction 3 2 Object 3 3 Definitions

More information

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group

More information

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3. Rev. 1 03/05/2015 ANNEX A to the Yokogawa Corporation of America Quality Assurance Manual For Additional Requirements selectively applied to ATEX and IECEx certified products CONTENTS 1. Scope 2. Purpose

More information

REGULATION FOR THE CE CERTIFICATION ACCORDING TO THE MEDICAL DEVICES DIRECTIVE

REGULATION FOR THE CE CERTIFICATION ACCORDING TO THE MEDICAL DEVICES DIRECTIVE TABLE OF CONTENTS 1. PURPOSE AND FIELD OF APPLICATION 2. GENERAL PRINCIPLES AND GUARANTEES FOR THE CUSTOMER 3. ACCESS REQUIREMENTS FOR CERTIFICATION 4. REQUIREMENTS OF THE ASSESSMENT PROCESS 5. SUSPENSION,

More information

Certification Rules of the Mark AEAS LUMINAIRES FOR EMERGENCY LIGHTING

Certification Rules of the Mark AEAS LUMINAIRES FOR EMERGENCY LIGHTING Certification Rules of the Mark Identification No : NF 015 Revision No : B July 2015 Application date : 2015-07-15 AEAS LUMINAIRES FOR EMERGENCY LIGHTING Certification Body mandated by AFNOR Certification:

More information

COMMISSION DELEGATED REGULATION (EU) /... of

COMMISSION DELEGATED REGULATION (EU) /... of EUROPEAN COMMISSION Brussels, 29.6.2017 C(2017) 4408 final COMMISSION DELEGATED REGULATION (EU) /... of 29.6.2017 amending Commission Delegated Regulation (EU) No 151/2013 of 19 December 2012 supplementing

More information

New Requirements for Placing of Medical Devices on the Market: Conformity Assessment to the Technical Regulations

New Requirements for Placing of Medical Devices on the Market: Conformity Assessment to the Technical Regulations New Requirements for Placing of Medical Devices on the Market: Conformity Assessment to the Technical Regulations September 2015 This summer the medical device circulation reform became one of the most

More information

Guidelines for designating and monitoring notified bodies in Norway

Guidelines for designating and monitoring notified bodies in Norway Guidelines for designating and monitoring notified bodies in Norway Version 13.12.2010 The Ministry of Trade and Industry has also prepared a Norwegian version of these guidelines. Questions may be directed

More information

(recast) (Text with EEA relevance) out the conformity assessment procedure. Conformity 20 February 2014.

(recast) (Text with EEA relevance) out the conformity assessment procedure. Conformity 20 February 2014. 29.3.2014 Official Journal of the European Union L 96/357 DIRECTIVE 2014/35/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating

More information

ANN ARBOR CITY NOTICE ORDINANCE NO. ORD ALARM SYSTEMS

ANN ARBOR CITY NOTICE ORDINANCE NO. ORD ALARM SYSTEMS ANN ARBOR CITY NOTICE ORDINANCE NO. ORD-16-14 ALARM SYSTEMS AN ORDINANCE TO AMEND SECTIONS 7:402, 7:405, 7:406, AND 7:407 OF CHAPTER 93, ALARM SYSTEMS, OF TITLE VII OF THE CODE OF THE CITY OF ANN ARBOR

More information

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance It is ordained by the Town Council of the Town of New Shoreham

More information

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR TF N 635 Regulation 574_2014: Annex III CPR and Regulation 568_2014: Annex V CPR 30-05-2014 28.5.2014 L 159/41 REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 574/2014 of 21 February 2014 amending

More information

EUROPEAN UNION. Brussels, 13 February 2014 (OR. en) 2011/0357 (COD) PE-CONS 54/13 ENT 190 MI 550 CONSOM 128 COMPET 470 CODEC 1481

EUROPEAN UNION. Brussels, 13 February 2014 (OR. en) 2011/0357 (COD) PE-CONS 54/13 ENT 190 MI 550 CONSOM 128 COMPET 470 CODEC 1481 EUROPEAN UNION THE EUROPEAN PARLIAMT THE COUNCIL Brussels, 13 February 2014 (OR. en) 2011/0357 (COD) PE-CONS 54/13 T 190 MI 550 CONSOM 128 COMPET 470 CODEC 1481 LEGISLATIVE ACTS AND OTHER INSTRUMTS Subject:

More information

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY ("Official Gazette of RS, issue No. 13/2010) I INTRODUCTION Scope Article 1 This Rulebook stipulates the essential requirements that shall be met with regard to

More information

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems BAFE Scheme: SP203-1 Version 7.1: January 2019 FIRE SAFETY REGISTER Fire Protection Industry Scheme, Reference SP203-1 For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire

More information

Tennessee Code/TITLE 62 PROFESSIONS, BUSINESSES AND TRADES/CHAPTER 32 FIRE PROTECTION/PART 1 FIRE PROTECTION SPRINKLER SYSTEMS

Tennessee Code/TITLE 62 PROFESSIONS, BUSINESSES AND TRADES/CHAPTER 32 FIRE PROTECTION/PART 1 FIRE PROTECTION SPRINKLER SYSTEMS Tennessee Code/TITLE 62 PROFESSIONS, BUSINESSES AND TRADES/CHAPTER 32 FIRE PROTECTION/PART 1 FIRE PROTECTION SPRINKLER SYSTEMS PART 1 FIRE PROTECTION SPRINKLER SYSTEMS Source: Tennessee Code/TITLE 62 PROFESSIONS,

More information

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland Electrical Safety Act (1135/2016) By decision of Parliament, the following is enacted:

More information

European Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till

European Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till SINTEF Building and Infrastructure P.O.Box 124 Blindern N-0314 Oslo Tel. 47 22 96 55 55 Fax 47 22 69 54 38 Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December

More information

DIRECTIVES. DIRECTIVE 2009/142/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 relating to appliances burning gaseous fuels

DIRECTIVES. DIRECTIVE 2009/142/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 relating to appliances burning gaseous fuels L 330/10 Official Journal of the European Union 16.12.2009 DIRECTIVES DIRECTIVE 2009/142/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 relating to appliances burning gaseous fuels

More information

Council Directive 93/68/EEC of 22 July 1993 amending Directives

Council Directive 93/68/EEC of 22 July 1993 amending Directives Council Directive 93/68/EEC of 22 July 1993 amending Directives 87/404/EEC (simple pressure vessels), 88/378/EEC (safety of toys), 89/106/EEC (construction products), 89/336/EEC (electromagnetic compatibility),

More information

Advokatfirmaet BAHR AS - ENGAGEMENT TERMS

Advokatfirmaet BAHR AS - ENGAGEMENT TERMS Advokatfirmaet BAHR AS - ENGAGEMENT TERMS 1. Scope These Engagement Terms regulate Advokatfirmaet BAHR AS s ( BAHR ) provision of legal and other services under the Engagement. 2. The engagement The Engagement

More information

Conformity assessment procedures for the Alarm Components Scheme

Conformity assessment procedures for the Alarm Components Scheme Conformity assessment procedures for the Alarm RD_070, Issue 20 This guide describes the conformity assessment procedures for Alarm Components. This Alarm certifies that Alarm Components comply with technical

More information

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems 5 August 2014 Certification of Alarm Communication Certification (ATS) Kiwa N.V. - 1-5 Augustus 2014 Preface This Evaluation Guideline (Certification Scheme) has been accepted by the Kiwa Board of Experts

More information

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL RULES AND REGULATIONS CONCERNING 8 CCR 1507-57 BUILDING AND FIRE CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR LIMITED GAMING

More information

BOARD OF EXAMINERS OF LANDSCAPE ARCHITECTS

BOARD OF EXAMINERS OF LANDSCAPE ARCHITECTS STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS BOARD OF EXAMINERS OF LANDSCAPE ARCHITECTS RULES AND REGULATIONS Revised RHODE ISLAND STATE BOARD OF EXAMINERS OF LANDSCAPE ARCHITECTS RULES OF THE BOARD

More information

Bureau Veritas Certification (India) Pvt. Ltd. - Use of Certification Marks

Bureau Veritas Certification (India) Pvt. Ltd. - Use of Certification Marks Contents 1. Introduction 2. Use of Certification Mark and Accreditation Body logo, IAF MLA mark 3. Use of client logo 4. Product Statement 5. Combined Certificate 6. How changes in certification cycle

More information

Certification reference document: ELECTRONIC SECURITY EQUIPMENT

Certification reference document: ELECTRONIC SECURITY EQUIPMENT Certification Body: AFNOR Certification 11, rue Francis de Pressensé 93571 LA PLAINE Saint Denis Cedex Tel: + 33 (0)1 41 62 80 00 Fax: + 33 (0)1 49 17 90 00 Web sites: www.afnor.org and www.marque-nf.com

More information

Article 3: Police Regulated Occupations and Businesses. Division 37: Burglary, Robbery and Emergency Alarm Systems

Article 3: Police Regulated Occupations and Businesses. Division 37: Burglary, Robbery and Emergency Alarm Systems Article 3: Police Regulated Occupations and Businesses Division 37: Burglary, Robbery and Emergency Alarm Systems 33.3701 Definitions Defined words appear in italics. Except as otherwise provided, for

More information

DRAFT COMMISSION DELEGATED REGULATION (EU) / of XXX

DRAFT COMMISSION DELEGATED REGULATION (EU) / of XXX DRAFT COMMISSION DELEGATED REGULATION (EU) / of XXX on making available on the market of unmanned aircraft intended for use in the open category and on third-country UAS operators THE EUROPEAN COMMISSION,

More information

Guidelines Cooperation between authorities under Articles 17 and 23 of Regulation (EU) No 909/2014

Guidelines Cooperation between authorities under Articles 17 and 23 of Regulation (EU) No 909/2014 Guidelines Cooperation between authorities under Articles 17 and 23 of Regulation (EU) No 909/2014 11 July 2017 ESMA70-151-435 Table of Contents 1 Scope... 3 2 Purpose... 5 3 Compliance and reporting obligations...

More information

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER 0780-02-14 FIRE EXTINGUISHERS TABLE OF CONTENTS 0780-02-14-.01 Definitions 0780-02-14-.09 Restrictions 0780-02-14-.02 Standards

More information

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety Foreword by Communities and Local Government Ministers It is always a priority to ensure safety from the

More information

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme: Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme: Solar products and components Accreditation Kiwa Italia S.p.A. Via Treviso 32/34 31020 San Vendemiano (TV) Italia Tel: +39

More information

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE) SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE) SCS/SF/053-8 Issue 1 Sira Certification Service INTRODUCTION One of the conditions placed on all holders of Sira

More information

DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL 29.3.2014 Official Journal of the European Union L 96/309 DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating

More information

The European Radio Equipment Directive 2014/53/EU

The European Radio Equipment Directive 2014/53/EU TÜV SÜD Slide 1 The European Radio Equipment Directive 2014/53/EU 28 March 2017 Meet the speaker behind the voice Jon Lea Senior Engineer (Product Certification), TÜV SÜD 30 years experience in the testing

More information

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS Mandated by CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT Certifying Body 84 avenue Jean Jaurès Champs sur Marne F 77442 MARNE-LA-VALLEE Cedex 2 11 rue Francis de Pressensé F 93571 LA PLAINE SAINT DENIS

More information

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - TF N 530 Rev.2 2012-04-13 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 Drafting

More information

NF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE

NF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE Mandated by CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT Certifying Body 84 avenue Jean Jaurès Champs sur Marne F 77442 MARNE-LA-VALLEE Cedex 2 rue Francis de Pressensé F 9357 LA PLAINE SAINT DENIS Cedex

More information

EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR HEALTH AND FOOD SAFETY

EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR HEALTH AND FOOD SAFETY EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR HEALTH AND FOOD SAFETY Brussels, 23 October 2018 REV1 Replaces the Q&A document published on 13 September 2017 QUESTIONS AND ANSWERS RELATED TO THE UNITED KINGDOM'S

More information

MONTGOMERY COUNTY RULES GOVERNING ALARMS SECTION 1. PURPOSE SECTION 2. DEFINITIONS

MONTGOMERY COUNTY RULES GOVERNING ALARMS SECTION 1. PURPOSE SECTION 2. DEFINITIONS MONTGOMERY COUNTY RULES GOVERNING ALARMS These rules and procedures are adopted pursuant to Chapter 233 of the Texas Local Government Code. SECTION 1. PURPOSE A. The purpose of these Rules is to encourage

More information

COMPILATION OF COMMUNITY PROCEDURES ON INSPECTIONS AND EXCHANGE OF INFORMATION

COMPILATION OF COMMUNITY PROCEDURES ON INSPECTIONS AND EXCHANGE OF INFORMATION EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Consumer goods Pharmaceuticals European Medicines Agency Inspections London, 18 May 2009 EMEA/INS/GMP/313510/2006 Rev 1 COMPILATION OF COMMUNITY

More information

DEPARTMENT OF AGRICULTURE, FORESTRY AND FISHERIES REGULATIONS REGARDING CONTROL OF THE EXPORT OF FRESH CUT FLOWERS AND FRESH ORNAMENTAL FOLIAGE

DEPARTMENT OF AGRICULTURE, FORESTRY AND FISHERIES REGULATIONS REGARDING CONTROL OF THE EXPORT OF FRESH CUT FLOWERS AND FRESH ORNAMENTAL FOLIAGE 40 No. 38189 GOVERNMENT GAZETTE, 14 NOVEMBER 2014 No. R. 886 14 November 2014 DEPARTMENT OF AGRICULTURE, FORESTRY AND FISHERIES AGRICULTURAL PRODUCT STANDARDS ACT, 1990 (ACT No. 119 OF 1990) REGULATIONS

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1500: Issue 2.1 provide compartmentation in buildings This standard defines the requirements for companies installing fire resisting compartment systems approved by LPCB to

More information

Securities Dealing Policy

Securities Dealing Policy Securities Dealing Policy INTRODUCTION PURPOSE AND OBJECTIVES As a public company, CSL is bound by laws governing the conduct for buying, selling and otherwise dealing in securities. This document sets

More information

PART 3 REQUIREMENTS FOR SPRINKLER SYSTEMS and SPRINKLER INSTALLERS

PART 3 REQUIREMENTS FOR SPRINKLER SYSTEMS and SPRINKLER INSTALLERS Page 1 of 42 CONTENTS Schedule of amendments for this part of the scheme document 3.0 Introduction 3.1 Business Licensing Requirements 3.2 Insurance 3.3 Language 3.4 Quality System 3.5 Safety System 3.6

More information

ENGROSSED SUBSTITUTE HOUSE BILL State of Washington 60th Legislature 2007 Regular Session

ENGROSSED SUBSTITUTE HOUSE BILL State of Washington 60th Legislature 2007 Regular Session ENGROSSED SUBSTITUTE HOUSE BILL 1968 State of Washington 60th Legislature 2007 Regular Session By House Committee on Commerce & Labor (originally sponsored by Representatives Simpson, Conway and Ormsby)

More information

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

A Notification under Article 12 of Regulation (EU) No 1025/2012 1 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Sustainable Growth and EU 2020 Standards for Boosting Competitiveness Brussels, 02/07/2014 A Notification under Article 12 of Regulation

More information

EXHIBIT A BE IT ORDAINED BY THE MAYOR AND THE CITY COUNCIL OF THE CITY OF BELLEVUE, NEBRASKA.

EXHIBIT A BE IT ORDAINED BY THE MAYOR AND THE CITY COUNCIL OF THE CITY OF BELLEVUE, NEBRASKA. EXHIBIT A 1 1 1 1 1 1 0 ORDINANCE NO. AN ORDINANCE TO AMEND ARTICLE VI OF CHAPTER OF THE BELLEVUE CITY CODE PERTAINING TO ALARM SYSTEM REGISTRATION REQUIREMENTS INCLUDING WITHOUT LIMITATION INCREASING

More information

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR)

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR) November 2013 Last updated: June 2015 Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR) Frequently Asked Questions Part IV Preliminary remarks

More information

Membership Scanning your card or entering your card number when in store or shopping Online Earning Member Benefits

Membership Scanning your card or entering your card number when in store or shopping Online Earning Member Benefits By registering as a member or claiming any Member Benefit, you agree to be bound by, and your participation in Lowes Rewards will be governed by, these Terms and Conditions. 1. Membership 1. To become

More information

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034 Guidance Note No 21/1 CE Marking Windows and doorsets to BS EN 16034 Introduction CE Marking of construction products has been a legal requirement since July 2013. It is a European requirement for all

More information

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision... CONTENTS Schedule of amendments for this part of the scheme document Page 1 of 14 3-O Introduction...3 3-O.1 Scope of Maintenance and Supervision...3 3-O.2 Certification conditions...5 3-O.3 LPS 1233 Service

More information

General Terms and Conditions of Use of the Wacker Neuson WebEDI Portal for Suppliers (Last Update: July 1 st, 2018)

General Terms and Conditions of Use of the Wacker Neuson WebEDI Portal for Suppliers (Last Update: July 1 st, 2018) General Terms and Conditions of Use of the Wacker Neuson WebEDI Portal for Suppliers (Last Update: July 1 st, 2018) Article 1 - Scope of Application 1.1 Wacker Neuson SE ( Wacker Neuson ) operates the

More information

POLICY & STANDARDS FOR CCTV OPERATION AT LSST

POLICY & STANDARDS FOR CCTV OPERATION AT LSST POLICY & STANDARDS FOR CCTV OPERATION AT LSST Document title: Policy & Standards for CCTV Operation at LSST Owner: Head of Security Approving body: Executive Committee Date of approval: September 2017

More information

Credit Suisse AG RULEBOOK OF THE ORGANIZED TRADING SYSTEM INTERNAL MARKET MAKING. 01 September 2018

Credit Suisse AG RULEBOOK OF THE ORGANIZED TRADING SYSTEM INTERNAL MARKET MAKING. 01 September 2018 Credit Suisse AG RULEBOOK OF THE ORGANIZED TRADING SYSTEM INTERNAL MARKET MAKING 01 September 2018 Table of Contents 1. 2. 3. 4. INTRODUCTION... 1 INSTRUMENTS... 1 USERS... 1 ORGANIZATION OF TRADING...

More information

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT These Conditions of Service apply to all NBN Services. These Conditions of Service form part of our Standard Form of Agreement found at www.adam.com.au/legal.

More information

COMMISSION IMPLEMENTING REGULATION (EU) /... of XXX

COMMISSION IMPLEMENTING REGULATION (EU) /... of XXX EUROPEAN COMMISSION Brussels, XXX SANTE/11949-2015 [ ](2015) XXX draft COMMISSION IMPLEMENTING REGULATION (EU) /... of XXX amending Implementing Regulation (EU) No 414/2013 specifying a procedure for the

More information

Part 1 Scope. Part 2 Definitions

Part 1 Scope. Part 2 Definitions Statutory Order on placing on the market of electrical and electronic equipment and management of waste electrical and electronic equipment (The WEEE Order) i,ii Pursuant to sections 9i (2), 9j(2), 9k

More information

REQUIREMENTS FOR THE ESTABLISHMENT OF PEST FREE PLACES OF PRODUCTION AND PEST FREE PRODUCTION SITES

REQUIREMENTS FOR THE ESTABLISHMENT OF PEST FREE PLACES OF PRODUCTION AND PEST FREE PRODUCTION SITES ISPM 10 INTERNATIONAL STANDARDS FOR PHYTOSANITARY MEASURES ISPM 10 REQUIREMENTS FOR THE ESTABLISHMENT OF PEST FREE PLACES OF PRODUCTION AND PEST FREE PRODUCTION SITES (1999) Produced by the Secretariat

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1196: Issue 1.2 This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information purposes only. Its use for testing, assessment,

More information

IFLA Regional Office for Latin America and the Caribbean: Call for Applications to host the Regional Office

IFLA Regional Office for Latin America and the Caribbean: Call for Applications to host the Regional Office IFLA Regional Office for Latin America and the Caribbean: Call for Applications to host the Regional Office Introduction The International Federation of Library Associations and Institutions http://www.ifla.org

More information

COMMISSION DELEGATED REGULATION (EU) /... of XXX

COMMISSION DELEGATED REGULATION (EU) /... of XXX Ref. Ares(2017)4156968-24/08/2017 EUROPEAN COMMISSION Brussels, XXX [ ](2017) XXX draft COMMISSION DELEGATED REGULATION (EU) /... of XXX establishing common safety methods on safety management system requirements

More information

This follows similar work previously conducted by Bureau Veritas for Nestlé S.A. in other global operations.

This follows similar work previously conducted by Bureau Veritas for Nestlé S.A. in other global operations. Nestlé S.A. Independent Assurance of Compliance with the Nestlé Policy and Instructions for Implementation of the WHO International Code of Marketing of Breastmilk Substitutes in Uganda (August 2016) Independent

More information

VdS Guidelines for the Certification of Monitoring and Alarm Receiving Centres according to DIN EN 50518

VdS Guidelines for the Certification of Monitoring and Alarm Receiving Centres according to DIN EN 50518 VdS Guidelines for the Certification of Monitoring and Alarm Receiving Centres according to DIN EN 50518 VdS 3137en : 2013-09 (02) Clause on non-binding character The present procedure guidelines VdS 3137

More information

The results of the impact assessment and of the workshop will be considered in the final proposal of the new directive.

The results of the impact assessment and of the workshop will be considered in the final proposal of the new directive. EUROPEAN COMMISSION ENTERPRISE DIRECTORATE-GENERAL Conformity and standardisation, new approach, industries under new approach Mechanical and electrical equipment (including telecom terminal equipment)

More information

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

Official Journal of the European Union. (Non-legislative acts) REGULATIONS L 146/1 II (Non-legislative acts) REGULATIONS COMMISSION IMPLEMENTING REGULATION (EU) 2016/879 of 2 June 2016 establishing, pursuant to Regulation (EU) No 517/2014 of the European Parliament and of the

More information

UWE CCTV Code of Practice

UWE CCTV Code of Practice UWE CCTV Code of Practice 1. Introduction... 1 2. Definitions... 1 3. Scope... 2 4. Ownership and Operation... 2 5. Principles... 2 6. Purpose of the CCTV System... 2 7. Data Protection Act 1998... 3 8.

More information

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Circuit Breakers JANUARY The electronic pdf version of this document found through   is the officially binding version STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for EU recognised organisation Mutual Recognition (MR) No. MR-E001 Circuit Breakers JANUARY 2013 The electronic pdf version

More information

INVITATION TO BID SUPPLY OF VARIOUS PORTABLE FIRE EXTINGUISHERS

INVITATION TO BID SUPPLY OF VARIOUS PORTABLE FIRE EXTINGUISHERS ASIAN DEVELOPMENT BANK 6 ADB Avenue, Mandaluyong City 550 Metro Manila, Philippines Tel: 632-4298; Fax: 636-2577 or 63-6899 Email: malbano@adb.org and sdiano@adb.org INVITATION TO BID SUPPLY OF VARIOUS

More information

COMMISSION DELEGATED REGULATION (EU) /... of

COMMISSION DELEGATED REGULATION (EU) /... of EUROPEAN COMMISSION Brussels, 8.3.2018 C(2018) 1392 final COMMISSION DELEGATED REGULATION (EU) /... of 8.3.2018 establishing common safety methods on safety management system requirements pursuant to Directive

More information

Shipboard incinerators with capacities up to 4000 kw

Shipboard incinerators with capacities up to 4000 kw STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for Marine Equipment Directive (MED) No. 431.90 - MED A.1/2.7 Shipboard incinerators with capacities up to 4000 kw JANUARY

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1531: Issue 1.1 companies installing or applying passive fire protection This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for

More information

ARTICLE 4-13 ALARM SYSTEMS * Division 1. Generally

ARTICLE 4-13 ALARM SYSTEMS * Division 1. Generally ARTICLE 4-13 ALARM SYSTEMS * Division 1. Generally Sec. 4-13-1 Definitions Alarm site. The single premises or location (one (1) street address) served by an alarm system or systems that are under the control

More information

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems BAFE Scheme: SP203-1 Version 5: May 2011 Fire Protection Industry Scheme, Reference SP203 Part 1 For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems British

More information

Exemptions Interprofessional practice: Architects and engineers are exempt for work which is incidental to their practice.

Exemptions Interprofessional practice: Architects and engineers are exempt for work which is incidental to their practice. Landscape Architecture Licensure Laws ASLA Summary of Provisions MAINE Maine Revised Statutes: Title 32, Chapter 3 A Code of Maine Rules: Chapter 2, Section 288 Type of Law: Title act. Maine State Board

More information

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax: STANDARD FOR CERTIFICATION No. 2.9 RADAR REFLECTOR JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation with

More information

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS TECHNICAL DOCUMENT 5: BIAXIALLY-ORIENTED PRESSURE PIPE GROUP

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS TECHNICAL DOCUMENT 5: BIAXIALLY-ORIENTED PRESSURE PIPE GROUP Mandated by CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT Certifying Body 84 avenue Jean Jaurès Champs sur Marne F 77442 MARNELAVALLEE Cedex 2 11 rue Francis de Pressensé F 93571 LA PLAINE SAINT DENIS Cedex

More information

Title 32: PROFESSIONS AND OCCUPATIONS

Title 32: PROFESSIONS AND OCCUPATIONS Title 32: PROFESSIONS AND OCCUPATIONS Chapter 139: MAINE FUEL BOARD Table of Contents Subchapter 1. GENERAL PROVISIONS... 3 Section 18101. DEFINITIONS... 3 Section 18102. LICENSE REQUIRED... 4 Section

More information

CORPORATION OF THE CITY OF KINGSTON. Ontario. By-Law Number A By-Law To Impose Fees For Automatic Alarms (False) False Alarm By-law

CORPORATION OF THE CITY OF KINGSTON. Ontario. By-Law Number A By-Law To Impose Fees For Automatic Alarms (False) False Alarm By-law CORPORATION OF THE CITY OF KINGSTON Ontario By-Law Number 2014-26 A By-Law To Impose Fees For Automatic Alarms (False) Passed: January 21, 2014 False Alarm By-law As Amended By By-Law Number: By-Law Number:

More information

Buying goods/services

Buying goods/services General contractual provisions Buying goods/services These are the only contractual provisions that apply between Fire and Emergency New Zealand and the Contractor. If any other provision is to apply or

More information

Page 1 of 5 CHAPTER 99 ALARM SYSTEMS [HISTORY: Adopted by the Township Committee of the Township of Hamilton as indicated in article histories. Amendments noted where applicable.] GENERAL REFERENCES Police

More information

1 of 1 DOCUMENT. NEW JERSEY REGISTER Copyright 2009 by the New Jersey Office of Administrative Law

1 of 1 DOCUMENT. NEW JERSEY REGISTER Copyright 2009 by the New Jersey Office of Administrative Law Page 1 1 of 1 DOCUMENT NEW JERSEY REGISTER Copyright 2009 by the New Jersey Office of Administrative Law VOLUME 41, ISSUE 9 ISSUE DATE: MAY 4, 2009 RULE PROPOSALS LAW AND PUBLIC SAFETY DIVISION OF CONSUMER

More information

FIRE SAFETY MANAGEMENT PLAN

FIRE SAFETY MANAGEMENT PLAN FIRE SAFETY MANAGEMENT PLAN February 2014 2 Document Control Revision: 1 Date: 4 February 2014 Status: Document change control: Approved by EPC Revision # Change Description Date Author 1 Initial document

More information

The New EMC Directive 2004/108/EC

The New EMC Directive 2004/108/EC The New EMC Directive 2004/108/EC In the process of this review I have tried to spell out in words what is often referred to as a section number while also keeping to location information as used in the

More information

ORDINANCE NO

ORDINANCE NO ORDINANCE NO. 2010-06 AN ORDINANCE OF THE CITY OF TOMBALL, TEXAS, AMENDING CHAPTER 26, EMERGENCY SERVICES OF THE CODE OF ORDINANCES OF THE CITY OF TOMBALL TO ESTABLISH POLICIES, PROCEDURES AND REGULATIONS

More information

New Legal Framework Carlo Casati

New Legal Framework Carlo Casati New Legal Framework Carlo Casati Milan, 1 April 2016 Summary New Legislative Framework Market Surveillance Conformity Assessment CE Marking 2 06.11.2013 NOTIFIED BODY TRAINING 01 New Legislative Framework

More information

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D BRL-K629/03 Date 01-02-2012 Evaluation Guideline for the Kiwa product certificate for Backflow protection devices Family E, Types A, B, C and D Preface Kiwa This (BRL) has been drawn up by Kiwa's Board

More information

RULES OF THE TENNESSEE ALARM SYSTEMS CONTRACTORS BOARD CHAPTER GENERAL PROVISIONS TABLE OF CONTENTS

RULES OF THE TENNESSEE ALARM SYSTEMS CONTRACTORS BOARD CHAPTER GENERAL PROVISIONS TABLE OF CONTENTS RULES OF THE TENNESSEE ALARM SYSTEMS CONTRACTORS BOARD CHAPTER 0090-01 GENERAL PROVISIONS TABLE OF CONTENTS 0090-01-.01 Purpose 0090-01-.08 Insurance Requirements 0090-01-.02 Definitions 0090-01-.09 Fees

More information

2430 Roman Forest Blvd. Ray Ricks Roman Forest, Texas Ordinance No. 215-A

2430 Roman Forest Blvd. Ray Ricks Roman Forest, Texas Ordinance No. 215-A Ordinance No. 215-A AN ORDINANCE OF THE CITY OF ROMAN FOREST, TEXAS ADOPTING SECURITY BURGLAR ALARM RULES; PROVIDING DEFINITIONS; PROVIDING FOR AN ALARM PERMIT REGISTRATION POLICY WITH FEES; PROVIDING

More information

COMMISSION DELEGATED REGULATION (EU)

COMMISSION DELEGATED REGULATION (EU) 28.5.2014 L 159/41 REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 574/2014 of 21 February 2014 amending Annex III to Regulation (EU) No 305/2011 of the European Parliament and of the Council on the

More information

Abu Dhabi Conformity Assessment Scheme for Fire Pumps

Abu Dhabi Conformity Assessment Scheme for Fire Pumps Abu Dhabi Conformity Assessment Scheme for Fire Pumps Assessment and Surveillance Plan Page i TABLE OF CONTENTS DEFINITIONS... 1 1 ABOUT THE ABU DHABI QUALITY AND CONFORMITY COUNCIL... 2 2 FOREWORD...

More information

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS (05/2011) PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS 3rd EDITION May 2011 Responsible Authority The Design, Equipment and Boating Safety Branch is

More information

While this translation was carried out by a professional translation agency, the text is to be regarded as an unofficial translation based on the

While this translation was carried out by a professional translation agency, the text is to be regarded as an unofficial translation based on the While this translation was carried out by a professional translation agency, the text is to be regarded as an unofficial translation based on the latest official Statutory Order no. 130 of 6 February 2014.

More information

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW! June 2018 DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW! How to recognize compliant cables? The new CPR defines the rules and the requirements of construction products to be manufactured, distributed

More information

PROCEDURE FOR HANDLING RAPID ALERTS AND RECALLS ARISING FROM QUALITY DEFECTS

PROCEDURE FOR HANDLING RAPID ALERTS AND RECALLS ARISING FROM QUALITY DEFECTS PHARMACEUTICAL INSPECTION CONVENTION PHARMACEUTICAL INSPECTION CO-OPERATION SCHEME PI 010-5 3 Appendices 1 July 2017 STANDARD OPERATING PROCEDURE PROCEDURE FOR HANDLING RAPID ALERTS AND RECALLS ARISING

More information