SensaModular. Simple, cost effective and easy to install for single-room lighting control

Size: px
Start display at page:

Download "SensaModular. Simple, cost effective and easy to install for single-room lighting control"

Transcription

1 SensaModular Simple, cost effective and easy to install for single-room lighting control

2 Introduction Thorn s Indoor Lighting Controls portfolio is grouped into three distinct usage types SensaLite features Thorn luminaires with built-in sensors and remote sensors, offering standard presence/absence detection, daylight-linking and infra-red control. SensaLite is the first step to comfort and energy saving, and is used for small office applications, simple classrooms, corridors etc: SwitchLite consists of switching presence/absence detection and photocells RotaryDIM offers precise manual control via a wall plate SensaDigital covers both features: Daylight-linked dimming, presence/ absence detection and manual override via an infra-red handheld controller 2. SensaModular is a portfolio of lighting control products designed for single room applications. The modular concept allows customers to build-up a set of components tailored specifically to their needs: Users can select modules for creating light scenes, enabling daylight-linking, integrating presence/absence detection, switching, scene setting and infra-red control Just the components needed are taken and connected to, up to three groups of dimmable luminaires via a controller 3. SensaLink features Thorn luminaires with built-in sensors and remote sensors offering presence detection, daylight linking and infra-red control, scene setting and the possibility to link sensors. It provides an interacting lighting management system for projects requiring greater levels of comfort. 2

3 What is SensaModular? SensaModular is for everyone looking for a versatile product that is easy to install and understand SensaModular controller with 3 luminaire outputs (DSI or DALI) Standard double or single momentary action switches to dim/brighten luminaire groups Scene Plate Infra-red handheld controller Multi-sensor Unlike traditional dimmer pack or building-wide solutions, it is a simple, cost effective modular solution capable of saving time and labour for all indoor single-room applications with two or three luminaire groups. Its modularity is based on the controller which interfaces with various combinations of scene plates, sensors, switches and receivers to operate groups of luminaires, thus offering users flexibility and comfort with the reassurance that all components integrate fully with each other. Key benefits are: 1. Different ways of presence linking, allowing SensaModular to be adapted to the required detection pattern, and different operation modes. 2. Three methods of daylightlinking, making it easy to tailor SensaModular to the application, especially in terms of size, usage and ceiling height. 3. Scene setting via: Scene plate, Infra-red handheld control or Switch input device. ix connection for up to 8 devices (sensors, scene plates, switch inputs, 1 photo cell) Multi-sensor 4. DSI/DALI auto detection outputs (patented) for controlling luminaire groups, the large SensaModular controller allows three digital outputs, the small controller two. Photo cell (max. 1) 5. Easy installation via polarityfree 2-wire connections, using standard mains rated installation material. 3

4 Performance, Efficiency and Comfort (PEC) for a better lit environment SensaModular evokes the spirit of Thorn Lighting s dynamic, results-orientated PEC programme The programme is based on the principle that Performance, Efficiency and Comfort determine the effectiveness of lighting, its impact on the people using it, and its impact on the natural environment. SensaModular delivers the right light on the right place at the right time. Performance: Providing the best visual effectiveness Dimming and Scene setting gives flexibility of the lighting configuration, therefore SensaModular ensures good task lighting wherever the task is. Efficiency: Conserving energy and effort, reducing CO 2 emissions and waste, providing lighting that is practical and efficient to install, operate and maintain. Presence-link conserves energy by ensuring unnecessary lighting is turned off. Daylight-link conserves energy by ensuring the task is lit to the correct level and not over lit, irrespective of the source of light. Maintenance control is provided with the SensaModular multi-sensors, i.e. constant task illuminance is given throughout the maintenance cycle of the lighting, conserving energy and easing the maintenance requirements. Polarity-free connections make SensaModular quick and easy to install with reduced possibility of errors. There are two screwdriver adjustable rotary switches on the front of the controller, which will set the operation mode and off delay time for the presence-link function. This makes commissioning quick, easy and safe being operated from the ground. SensaModular gives us a lighting system we can manage effectively and ensures that the whole lighting performs as designed. Comfort: giving people satisfaction and stimulation Personalised light, either with dimming or with scene setting, allows the ambience of the space to be altered to suit the usage requirements. SensaModular allows the variability of the light through time, giving a more interesting and stimulating environment. 4

5 Energy saving potential By conserving energy we give better value for money whilst saving global resources Milestones to energy conservation with modern lighting Fluorescent lamp and conventional ballast Fluorescent lamp and low-loss ballast Fluorescent lamp and electronic ballast Fluorescent lamp and dimmable electronic ballast Fluorescent lamp and dimmable electronic ballast 0% -7% Manual dimming -22% Daylight-link -42% Presence-link -55% -61% System with T26 fluorescent lamps -71% -82% System with T16 fluorescent lamps Baseline Savings potential The CELMA (Federation of National Manufacturers Associations for Luminaires and Electrotechnical Components for Luminaires in the European Union) highlights the potential energy savings that dimmable electronic ballasts, day-light link and presence-link offer, as shown in the picture above. SensaModular allows the realisation of these energy savings in every single room indoor lighting application. 5

6 Key Benefit - Tailored-fit presence-link The most expensive light is the one that is still on in unoccupied rooms or areas. SensaModular enables you to automatically conserve energy whenever people are absent, allowing you to choose between three options: Using one SensaModular multi-sensor per luminaire group The SensaModular multi-sensors provide a presence-link function that may be allocated to the luminaire groups individually. This option is perfect for applications with zoned lighting, e.g. group offices, and considers the recommendations regarding presence-link stated in EN 15193, asking for zoned presence-link in applications larger than 30m 2. Using one SensaModular multi-sensor for all luminaire groups This option provides a presence-link function for all luminaire groups connected to the SensaModular controller, and is ideal in small applications where daylight-link and infra-red control are required. Using one SwitchLite presence detector for all luminaire groups Any standard 230 VAC presence detector, e.g. one of the Thorn SwitchLite portfolio, can be used as an alternative to the SensaModular multi-sensors. This can be connected to the dedicated PD input of the controller and is allocated to all luminaire groups. This option is perfect for any application requiring a different detection pattern to that of the SensaModular multi-sensor, for instance corridors and staircases, and also for applications where no daylight-link and infra-red control is needed. 6

7 On/Off On/Off On/Off PD only Off PD only Off PD only Off On/Corridor On/Corridor On/Corridor PD Mode PD Mode PD Mode The SensaModular control unit features two inbuilt rotary switches that allow the user to determine the desired operation mode and Off Delay time for the presencelink function. These are easily and quickly set using a screwdriver. Presence- and absence-link (On/Off mode) Lighting is switched On whenever a person is detected by a connected sensor, and is slowly faded to Off, after a set Off delay time, as soon as the sensor detects absence. If several sensors are used then SensaModular will delay fading to Off until all of the sensors have reported absence. Absence-link (only Off mode) Lighting is slowly faded to Off, after a set Off delay time, as soon as a connected sensor detects absence. If several sensors are used then SensaModular will delay fading to Off until all of the sensors have reported absence. The lighting will never be switched On automatically in this mode and will have to be activated manually, using the scene plate, the momentary action switches or the infra-red handheld control. Presence-linked Corridor scene (On/Corridor mode) Lighting is switched on whenever a person is detected by a connected sensor, and is slowly faded to a lower corridor illuminance level, after a set Off delay time, as soon as the sensor detects absence. If several sensors are used then SensaModular will delay fading to the corridor illuminance level until all of the sensors have reported absence. The corridor illuminance level is set to 10% light output for all luminaires. On/Off On/Off PD only Off PD only Off On/Corridor On/Corridor PD Mode Off Delay (min) PD Mode Off Delay (min) Deactivated presence-link SensaModular allows all connected presence detectors or the presence-link function of all connected SensaModular multi-sensors to be deactivated. This mode also helps when the SensaModular installation is commissioned. Off Delay time After detecting absence SensaModular will wait for a configurable Off time delay before fading to the absence setting specified with the set operation mode. This time delay can be between 0 seconds and 1 hour. Note: If a standard presence detector (e.g. SwitchLite) is used, its own Off Delay time is added to that set on the SensaModular controller. Staircase function By connecting a standard momentary action switch to the SensaModular controller s presence detector (PD Input), a staircase function can be realised. Activating the momentary action switch announces presence and the lighting is switched On. After the set Off delay time the lighting is faded to Off, if the operation mode is set to On/ Off, or alternatively faded to a corridor illuminance level of 10%, if the mode is set to On/Corridor. 7

8 Key Benefit - Tailored-fit daylight-link 0% 25% 50% 0% 25% 50% 0% 25% 50% 500lux 500lux 500lux Daylight Daylight Daylight Artificial light Artificial light Artificial light Using one look down multi-sensor per luminaire group For daylight-linking one multi-sensor per luminaire group is installed on the ceiling, aimed at the working plane to register the light level. Advantages: Supports the recommendations stated in EN 15193, which ask for daylight-linking of zones smaller than 30m 2, thus resulting in a good rating of the installation for building passport purposes. Maintains illuminance despite aging of lamps and dirt on luminaires. Ideal for larger, zoned applications, like group offices. SensaModular multi-sensor heads combine daylight with presence linking and infra-red control. Points to consider: Measures daylight and artificial light reflected from desktop therefore influenced by reflecting material and colour. Several sensors needed (one per luminaire group), therefore more obtrusive. Impact of overlapping detection zones. Using one look out photocell for all luminaire groups For daylight-linking one photocell sensor is installed on the ceiling and aimed in the direction of the window to register incoming daylight. Advantages: Visual and physical intrusion on the ceiling is kept to a minimum as only one sensor is needed to register the flow of daylight for up to three individually controlled luminaire groups. With only daylight to register measurements are precise, thus maximising daylight saving potential. Ideal for applications with luminaire rows and/or ceiling heights of more than 3m, or where zoned presence-link is not required, e.g. classrooms, industrial or sports halls. Points to consider: Does not consider aging of lamps and luminaires becoming dirty. SensaModular photocell does not provide presence-linking and infra-red control. Using one look down multi-sensor for all luminaire groups For the daylight-linking of smaller rooms, e.g. a single office or meeting room, one multi-sensor for all luminaire groups is installed on the ceiling, aimed at the working plane to register the light level. Advantages: For applications not requiring zoned areas, visual and physical intrusion on the ceiling is kept to a minimum as only one sensor is needed to register the flow of daylight for up to three individually controlled luminaire groups. Maintains illuminance despite aging of lamps and dirt on luminaires. The SensaModular multi-sensor head combines daylight with presence-linking and infra-red control. Points to consider: Measures daylight and artificial light reflected from one local desktop therefore influenced by reflecting material and colour. Does not consider the recommendations stated in EN in applications larger than 30m 2. 8

9 Key Benefit - Scene setting No application is used for only one activity or task: Therefore SensaModular allows a user to set scenes and to adapt the lighting to the different tasks. Scene plate With the wall recessed SensaModular scene plate three scenes as well as the Off scene can be set and recalled. The active scene is visualised with indicator LEDs integrated into the keys. Three pairs of keys are used to dim and brighten the luminaire groups individually and a further pair allow all luminaires to be dimmed or brightened. The scene plate has a brass front in satin steel finish, matching back boxes are available as accessories. Infra-red handheld control The SensaModular infra-red handheld controller allows the setting and recalling of three scenes and the Off scene. The whole lighting can be dimmed and brightened via a rocker key, or after using the pre-selection buttons the luminaire groups can be dimmed individually. This device is also used to allocate the SensaModular multisensors to the luminaire groups. For the reception either the SensaModular multi-sensors or (if these are not planned in) the SensaModular infra-red sensors must be used. Switch input device As an alternative to the wallrecessed scene plate, standard momentary action switches can be used in conjunction with the SensaModular switch input device to recall three scenes and the Off scene. 9

10 Key Benefit - DSI/DALI auto detection SensaModular uses DSI/DALI auto detection luminaire outputs (patented), and allows you to connect either: Luminaires with electronic ballasts showing DSI (Digital Serial Interface) controllability, e.g. Thorn HFD luminaire versions Luminaires with DALI (Digital Addressable Lighting Interface) controllability, e.g. Thorn HFX luminaire versions One ballast type, either DSI or DALI, can be connected to each controller output (see table for permitted configurations and quantities) Every luminaire output of a SensaModular controller will check, individually, the type of ballasts used and automatically adapt its control language. Maximum number of ballasts connected to SensaMod-2DIG controller Output Grp1 Grp2 HFD luminaires only 50 DSI 50 DSI HFX luminaires only 25 DALI 25 DALI HFD or HFX luminaires 25 DSI or DALI 25 DSI or DALI Maximum number of ballasts connected to SensaMod-3DIG controller Output Grp1 Grp2 Grp3 HFD luminaires only 50 DSI 50 DSI 50 DSI HFX luminaires only 25 DALI 25 DALI 25 DALI HFD or HFX luminaires 25 DSI or DALI 25 DSI or DALI 25 DSI or DALI Note: A DSI amplifier is available as accessory to increase the number of connectable DSI ballasts (DSI-V, ). HFD - High Frequency Digital Dimmable DSI HFX - High Frequency Digital Dimmable DALI Key Benefit - Easy to Install When wiring the system, the two or three groups of HFD or HFX luminaires are allocated to the momentary action switches for direct manual control. One intelligent interface ( ix connection) is used for all user interfaces and sensors, e.g. multi-sensor heads or photocell, infra-red sensor, scene plate, momentary action switch input. There is no extra commissioning tool required. The infra-red handheld controller is used to allocate the multi-sensors to the luminaire groups. Regarding installation material; installers benefit from polarity-free connections and the possibility to use standard mains rated wiring. DSI or DALI wiring, ix wiring Polarity-free. Standard mains wiring, e.g. H05VV-U 2 x 1.5mm 2 and H05VV-U 2 x 0.75mm 2. For maximum lengths see table below. Wiring typologies: tree, star, line, radial. Wire diameter Maximum length ix and DALI wires Maximum length DSI wires 2 x 0.5mm 2 100m 125m 2 x 0.75mm 2 150m 125m 2 x 1.0mm 2 200m 125m 2 x 1.5mm 2 300m 250m 10

11 How to plan a SensaModular installation The cascading diagram below helps you evaluate and chart possible outcomes when seeking the benefits of energy saving and comfort Luminaire grouping chosen for application? Zones (and ceiling height max. 3m) Rows in parallel with window (or ceiling higher than 3m) Daylight linked? Presence linked? Presence linked? Presence linked? Presence linked? Yes Multi-sensors (look down) Yes Multi-sensors (look down, PD) Via wall mounted plate? Yes No Yes Multi-sensors (look down) No No Scene setting? Photocell (look out) SwitchLite presence detector Via infra-red handheld control? Yes Yes Yes No Photocell (look out) Yes SwitchLite presence detector No Via standard switches? Yes No Comfort Energy Saving Scene Plate Remote Control * * plus Infra-red Sensor if no Multi-sensor is used Input for standard switches How are the luminaire groups arranged in zones (e.g. using recessed louvre luminaires) or in rows (e.g. using suspended linear luminaires)? How high is the ceiling? Is daylight available and daylight-linking possible? Is presence-link also required? Energy Saving Based on the answers to these questions you decide to select either: the SensaModular multi-sensors, or the SensaModular photocell perhaps combined with a SwitchLite presence detector. Now choose any additional modular items: Do you want to set scenes? (Note: Scene 1 would be the daylightlinked one). If yes, would you prefer: Comfort - The SensaModular Scene Plate, that allows you to brighten and dim the luminaire groups individually and jointly, and to set and recall three scenes plus Off? It also indicates the active scene. This plate is perfect for meeting rooms, retail applications and much more. - Or an Infra-red handheld control? This would be optimal in any office application. (Note: If you have not chosen a multi-sensor head above, then you will need a Infra-red Sensor as well). - Or standard momentary action switches for recalling scenes? These would interface via the SensaModular Switch Input into the system. 11

12 Application example - Group Office Description of application: Example: Graphic design agency Number of users: < 15 Size: < 100m 2 Activities: PC work, desk work, break, cleaning Area of activity: Zone within an area, e.g. a working team s desk cluster Luminaire layout: Arranged in three zones, with a group of recessed luminaires above each desk cluster Ceiling height: 2.8m Needs and requirements Light level per zone adaptable to activities Saving Energy Easy to install and to commission, no need for a specialist or training Solution Multi-sensors detect presence/absence and dim/brighten light according to incoming daylight Individual manual dimming is provided via momentary action switches, or optional infra-red handheld controller, to override a zone s light level if needed Infra-red handheld controller used to allocate multi-sensors to the luminaire groups Detection mode and Off delay set via rotary switches, illuminance levels programmed via infra-red handheld controller, or via momentary action switch temporarily connected to lux input of SensaMod-3DIG Standard mains wiring only, polarity-free DSI/DALI and sensor wires One of three zones Group 3: DSI or DALI out Group 2: DSI or DALI out Group 1: DSI or DALI out ix Intelligent connection for sensors and scene setting devices Group 1 Group 2 Group 3 Needed for programming L N Group 1 Group 2 Group 3 12

13 Application example - Classroom Description of application Example: Primary school Number of users: < 25 Size: < 70m 2 Activities: Lessons, breaks, cleaning Area of activity: Room Luminaire layout: Arranged in rows, two groups, parallel to the window Ceiling height: 3m Needs and requirements Saving energy Vandal resistant operation, optionally protected Easy to use (especially in shared or public rooms) Easy to install and to commission, no need for a specialist or training Solution Lighting is linked to the incoming daylight using 1 photocell (looking towards the window) for all luminaire groups Wall mounted passive infra-red or unobstrusive Microwave presence detector for all luminaire groups, e.g. one of Thorn s SwitchLite portfolio Manual switching and dimming via standard key operated double momentary action switches to override light levels if needed (keys for teachers, facility manager, cleaner) Detection mode and Off delay set via rotary switches, illuminance level programmed either via push button built into photocell, or via momentary action switch temporarily connected to lux input of SensaMod-2DIG Standard mains wiring only, polarity-free DSI/DALI and photocell wires Group 2: DSI or DALI out Group 1: DSI or DALI out ix Intelligent connection for sensors and scene setting devices All groups L N Presence detector allocated to all groups Group 1 Group 2 13

14 Application example - Sports Hall Description of application Example: Swimming pool without large windows Number of users: < 50 Size: < 500m 2 Activities: Public swimming, competition, cleaning Area of activity: Hall Luminaire layout: Arranged in rows, three groups Ceiling height: 5 to 10m Needs and requirements Light level adaptable to different activities Saving energy Easy to use Easy to install and to commission, no need for a specialist or training Solution A scene plate allows the setting and selection of 3 scenes, thus matching the lighting to the different activities taking place. Light levels can be overridden individually if required. Standard mains wiring only, polarity-free DSI/DALI and scene plate wires Group 3: DSI or DALI out Group 2: DSI or DALI out Group 1: DSI or DALI out ix Intelligent connection for sensors and scene setting devices L N 14

15 Product details SensaMod-3DIG Digital output unit for controlling three luminaire groups, with three control outputs for DSI or DALI compatible lamp control gears (auto detection). Up to 25 DALI or 50 DSI ballasts per output channel are connected via a polarity-free two-wire connection using standard mains rated wiring. Dimming range 1 to 100% (depending on ballasts). The unit shows an intelligent input for the connection of multi-sensors, infra-red sensors, a photocell, scene plates and switch input devices (max. 8 devices in parallel with only one photocell to be used) via a polarity-free two-wire connection using standard mains rated wiring. Additionally standard single or double momentary action switches can be connected to switch, dim and brighten the luminaire groups individually; standard mains rated presence detectors can be connected to link all luminaire groups to presence. Two rotary switches to set presence detection mode and Off delay time. All connections made via screw-terminals. Status LED and test button. Housing made of flame-retardant polycarbonate, halogen free, for installation into distribution cabinets on 35mm DIN rail, according to EN 50022, IP20 degree of protection, ambient temperature 0 to 50 C. Width 140mm (8 units), height 90mm, depth 59mm. Weight 650g SensaMod-2DIG Digital output unit for controlling two luminaire groups, with two control outputs for DSI or DALI compatible lamp control gears (auto detection). Up to 25 DALI or 50 DSI ballasts per output channel are connected via a polarity-free two-wire connection using standard mains rated wiring. Dimming range 1 to 100% (depending on ballasts). The unit shows an intelligent input for the connection of multi-sensors, infra-red sensors, a photocell, scene plates and switch input devices (max. 8 devices in parallel with only one photocell to be used) via a polarity-free two-wire connection using standard mains rated wiring. Additionally standard single or double momentary action switches can be connected to switch, dim and brighten the luminaire groups individually; standard mains rated presence detectors can be connected to link both luminaire groups to presence. Two rotary switches to set presence detection mode and Off delay time. All connections made via screw-terminals. Status LED and test button. Housing made of flame-retardant polycarbonate, halogen free, for installation into distribution cabinets on 35mm DIN rail, according to EN 50022, IP20 degree of protection, ambient temperature 0 to 50 C. Width 70mm (4 units), height 90mm, depth 59mm. Weight 350g SensaX-MULTISENSOR Multi-sensor for presence-link, daylight-link and integration of infra-red handheld controllers. Presence-link via passive infra-red sensor, circular detection pattern at 2.5(3)m ceiling height is diameter 6(7)m for seated persons, and diameter 7(9)m for persons in motion. Daylight-link is realised with sensor looking down at task area, measuring the daylight as well as the artificial light reflected from the task area. Connected to and supplied by central control device via a polarity-free two-wire connection using standard mains rated wiring. Either semi-recessed into single Euro ceiling back box, diameter 60mm, or surface-mounted onto ceiling or fully recessed into suspended ceiling (cut out diameter 92mm) with accessory rings provided, mounting height 3m max. Connection made via screwless push-in terminals. Green status LED behind lens for indication. Housing made of flame-retardant polycarbonate, white (RAL 9003), lens made of high density polyethylene, both halogen free. IP40 degree of protection, ambient temperature 0 to 50 C. Weight 50g. 15

16 SensaX-IRSENSOR Infra-red sensor for integration of infra-red handheld controllers. Connected to and supplied by central control device via a polarity-free two-wire connection using standard mains rated wiring. Either semi-recessed into single Euro ceiling back box, diameter 60mm, or surface-mounted onto ceiling or fully recessed into suspended ceiling (cut out diameter 92mm) with accessory rings provided. Connection made via screw less push-in terminals. Status LED behind lens for indication. Housing made of flame-retardant polycarbonate, white (RAL 9003), lens made of high density polyethylene, both halogen free. IP40 degree of protection, ambient temperature 0 to 50 C. Weight 50g SensaX-DAYSENSOR Photocell for daylight-link. Daylight-link is realised with sensor looking from ceiling towards window, measuring the daylight entering a room. Connected to and supplied by central control device via a polarityfree two-wire connection using standard mains rated wiring. Surface-mounted onto ceiling. Connection made via screw-terminals. Status LED behind lens for indication. Integrated test and program button. Housing made of flame-retardant polycarbonate, white (RAL 9003), halogen free. IP20 degree of protection, ambient temperature 0 to 50 C. Weight 40g SensaX-IRCONTROL Infra-red hand held controller for setting and recalling three scenes and Off scene. Controller includes one On/Off key, three scene keys, one dimming rocker key and five keys for pre-selection of luminaire groups. The whole lighting can be dimmed and brightened via the rocker key, or after using the pre-selection keys the luminaire groups can be dimmed and brightened individually. Device additionally used for allocation of multi-sensors to luminaire groups. Status LED for indication. Supplied by 2 batteries type AAA, included. Range up to 10m, IR protocol RSTEP, 38kHz. Housing made of ABS, halogen-free, wall-mounting bracket included, ambient temperature 0 to 40 C SensaX-SCENE Scene plate for setting and recalling three scenes and Off scene. Active scenes visualised with indicator LEDs integrated into the keys. Four pairs of keys for dimming and brightening luminaire groups individually as well as jointly. Connected to and supplied by central control device via a polarity-free two-wire connection using standard mains rated wiring. Front plate made of brass in satin steel finish, hiding screws after installation. Wall recessed into back boxes, available as accessories. Connection made via detachable plug with screwterminals. Connection of protective earth via separate screw-terminal. IP20 degree of protection, ambient temperature 0 to 50 C. Width 145mm, height 86mm. Depth without plate 25mm, depth of plate 4mm. Weight 350g. 16

17 RBOX2 PS CONTROLITE Back box plastic (polystyrene, halogen-free) 2-gang for the wall recessed installation of the SensaX-SCENE scene plate. Suitable for flush fitted installation into cavity walls. Outside dimensions 134x74mm, depth 36mm (without rim and clamps) RBOX2 ST CONTROLITE Back box stainless steel 2-gang for the wall recessed installation of the SensaX-SCENE scene plate. Suitable for flush fitted concealed installation into brick or concrete walls. Outside dimensions 134x74mm, depth 28mm SensaX-4SWITCH Switch input device to recall three scenes and the Off scene, or alternatively to switch, dim and brighten three luminaire groups individually and jointly, via volt-free standard momentary action switches. Connected to and supplied by central control device (ix connection) via a polarity-free two-wire connection using standard mains rated wiring. Connection of up to four volt-free momentary action switches, switch function, scene recall or group dimming and brightening, set via built-in rotary switch. Recessed into back box behind switches. Connection made via pre-connected wires, length approx. 30cm. Housing made of flame-retardant polycarbonate, transparent, halogen free. IP20 degree of protection, ambient temperature 0 to 50 C. Diameter 53mm, height 13mm. Weight 100g PDAX 500VA Phase dimmer/reverse phase dimmer (automatic load detection) with DSI interface, controllable via SensaModular output, for continuous dimming of ohmic light sources, LV halogen lamps with magnetic or electronic transformers. A total connected load of 40 to 500VA can be operated. Dimming range 1 to 100%. Connection via screw terminals, housing made of flame-resistant polycarbonate, halogen-free, suited for ceiling recess, ambient temperature 0 to 60 C (max. 300VA)/0 to 45 C (max. 500VA). IP20 degree of protection. Length 167mm, width 42mm, height 31mm. Weight 200g. 17

18 PDAS 1000VA Phase dimmer/reverse phase dimmer (automatic load detection) with DSI interface, controllable via SensaModular output, for continuous dimming of ohmic light sources, LV halogen lamps with magnetic or electronic transformers. A total connected load of 40 to 1000VA can be operated. Dimming range 1 to 100%. Connection via screw terminals, housing made of flame-resistant polycarbonate, halogen-free, suitable for installation in switch or distribution cabinets on 35mm DIN rail. Ambient temperature 0 to 40 C. IP20 degree of protection. Width 105mm (6 units), height 90mm, depth 59mm. Weight 400g TE one4all sc 105VA Digital, dimmable transformer with DSI/DALI interface; controllable via SensaModular output (identified as DALI ballast), dimming range of 1 to 100%; for operation of 12V low voltage tungsten-halogen lamps with a lamp power of between 20 and 105VA; lamp leads up to 2m; housing made of flame-resistant polycarbonate, halogen-free; suitable for ceiling recess; protection class II; ambient temperature -25 to +60 C. Length 167mm, width 42mm, height 31mm. Weight 180g TE one4all sc 150VA Digital, dimmable transformer with DSI/DALI interface; controllable via SensaModular output (identified as DALI ballast), dimming range of 1 to 100%; for operation of 12V low voltage tungsten-halogen lamps with a lamp power of between 50 and 150VA; lamp leads up to 2m; housing made of flame-resistant polycarbonate, halogen-free; suitable for ceiling recess; protection class II; ambient temperature -20 to +50 C. Length 207mm, width 46mm, height 40mm. Weight 290g DSI-V Digital device for amplifying the DSI signal, enables connection of 50 additional DSI compatible operating devices, like digital electronic ballasts, phase dimmers or electronic transformers, to the DSI output of SensaModular after the maximum number of DSI ballasts has been reached. The DSI load of the DSI-V is equivalent to the load of 2 DSI ballasts. Serial connection of up to 5 amplifiers possible. DSI input and output. Connections made with push-in terminals; housing made of flame-resistant polycarbonate, halogenfree, suitable for ceiling-recess, IP20 degree of protection, protection class II with fitted terminal covers, ambient temperature 0 to 60 C. 18

19 Ordering Guide Ordering Guide Description Weight (Kg) SAP code SensaModular DSI/DALI Output 3x and 2x SENSAMOD-3DIG SENSAMOD-2DIG SensaModular multi-sensor, infra-red sensor and photocell SENSAX-MULTI-SENSOR SENSAX-IRSENSOR SENSAX-DAYSENSOR SensaModular Infra-red Handheld Control SENSAX-IRCONTROL SensaModular Scene Plate and back boxes, polystyrene and steel SENSAX-SCENE RBOX2 PS CONTROLITE RBOX2 ST CONTROLITE SensaModular 4-fold scene or group switch input SENSAX-4SWITCH Accessories: DSI phase/reverse phase dimmers, auto load detection, VA and VA PDAX 500VA PDAS 1000VA Accessories: DSI/DALI electronic transformers, 12V, VA and VA TE ONE4ALL SC 105VA TE ONE4ALL SC 150VA Accessory: DSI amplifier for 50 additional DSI loads DSI-V Connecting Accessories Further DALI out Further DSI out DSI in load out PDAX/PDAS DSI in DSI-V DSI out Further 50 DSI out DALI in load out TE one4all 19

20 Lighting people and places Thorn Lighting Limited UK Silver Screens, Elstree Way, Borehamwood, Hertfordshire, WD6 1FE UK Project Pricing Quotations Tel: Fax: UK Sales desk - Orders/Stock Enquiries Tel: Fax: Ireland Thorn Lighting (Ireland) Limited Century House Harolds Cross Road Dublin 6W Tel: (353) Fax: (353) dublinsales@thornlighting.com Thorn Olympics Sports Lighting Team Tel: olympics.team@thornlighting.com Spare Parts Tel: Fax: spares@thornlighting.com Technical Support Tel: Fax: technical@thornlighting.com Brochureline Answering Service Brochures on specific products/ranges Tel: Fax: brochures.uk@thornlighting.com Thorn Lighting is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. The right is reserved to change specifications without prior notification or public announcement. All goods supplied by the company are supplied subject to the company s General Conditions of Sale, a copy of which is available on request. All measurements are in millimetres and weights in kilograms unless otherwise stated. Publication No: 397 (GB) Publication Date: 02/10 SAP code: Member of The Lighting Industry Federation ISO 9001:2008 Reg: AT-00005/5 ISO 14001:2004 Reg: AT-00247/2 Manufacturing

SensaModular. Simple, cost effective and easy to install for single-room lighting control

SensaModular. Simple, cost effective and easy to install for single-room lighting control SensaModular Simple, cost effective and easy to install for single-room lighting control Introduction Thorn s Indoor Lighting Controls portfolio is grouped into three distinct usage types 1 2 3 1. SensaLite

More information

IndiQuattro. Same great looks but slimmer and better performance

IndiQuattro. Same great looks but slimmer and better performance IndiQuattro Same great looks but slimmer and better performance IndiQuattro With up to 70% LOR and a new, slimline 70mm body, IndiQuattro is now better performing and even easier to install Easy to install

More information

Elevation. Restyled recessed fluorescent luminaire with greater performance, efficiency and practicality

Elevation. Restyled recessed fluorescent luminaire with greater performance, efficiency and practicality Elevation Restyled recessed fluorescent luminaire with greater performance, efficiency and practicality Whether in an office, conference room or learning space, face to face communication between people

More information

SENSA MRE DDM MR

SENSA MRE DDM MR 96239831 SENSA MRE DDM MR Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring and fixing 3 4 Programming 6 5 Wiring diagrams 8 6 Detection pattern diagrams

More information

SWITCHLITE MRE SLDM ADJ

SWITCHLITE MRE SLDM ADJ 96239855 SWITCHLITE MRE SLDM ADJ Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Installation 3 4 Fixing - Flush 4 5 Fixing - Surface 4 6 Head locking

More information

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PPAD-C-HB-DALI-230V Product Guide Ceiling PIR HS presence detector DALI / DSI dimming Overview The PPAD-C-HB-DALI-230V PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

SWITCHLITE MRE DDM ADJ

SWITCHLITE MRE DDM ADJ 96239889 SWITCHLITE MRE DDM ADJ Front features Mounting Bezel Back features Retaining Spring Power Input & Switched Output Connector (Channel 1) Sensor Lens which covers... Microwave Sensor IR Receiver

More information

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features EBDHS-DD-LT30 Product Guide Ceiling PIR HS presence detector DALI / DSI, low temperature Overview The EBDHS-DD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MWS6-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS6-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual

More information

Direct Dim Microwave Presence/Absence Detector

Direct Dim Microwave Presence/Absence Detector Product Guide MWS3A-DD Direct Dim Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Fixing 3 4 Installation 3 5 Fixing

More information

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications Simple Fit Switching Sensors 1.8m to 3m Cone-shaped detection pattern, 6m radius at mounting height 6.0m AC220~240V/50Hz MK Simple Fit Sensors offer cost effective presence detection for lighting control

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MWS3A-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS3A-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual

More information

SMART BASIC BASIC-IR DAYLIGHT

SMART BASIC BASIC-IR DAYLIGHT LUXMATE Lighting Control System LUXMATE. The ing system for maximum quality and dimming convenience. SMART BASIC BASIC-IR DAYLIGHT The art of modern technology lies in making complicated things simple.

More information

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR 8. SPECIFICATION LOAD 6 Amps fluorescent and incandescent lighting. 3 Amps compact fluorescent lighting. 3 Amps low energy lighting. 3 Amps low voltage lighting (switch primary of transformer). Switch

More information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor. Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55 96239823 SWITCHLITE MRE SLD MAN 96239821 SWITCHLITE MRE SLD IP55 Overview The SWITCHLITE MRE SLD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Integrated PIR detectors

Integrated PIR detectors EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1 Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) DALI/DSI output channels with adjustable negative offset from channel to channel 1 Ambient light

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-A-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-A-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual

More information

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor ILD Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) 2 DALI/DSI output channels

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. Product Guide LPCMPIRDSI Ceiling PIR presence detector DALI / DSI dimming Overview The LPCMPIRDSI PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Analogue Dimming Microwave Presence/Absence Detector

Analogue Dimming Microwave Presence/Absence Detector Product Guide MWS3A-AD Analogue Dimming Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Fixing 3 4 Installation 3

More information

DALI MSensor 02 Multi-sensor for DALI system

DALI MSensor 02 Multi-sensor for DALI system MSensor 02 Multi-sensor for system Component of the comfortdim system ( standalone) With ambient light dependent control and motion detection Simple group assignment via rotary switch Multiple MSensors

More information

Energy efficient lighting control

Energy efficient lighting control Energy efficient lighting control 2015/2016 Brighter Lighting With intelligent sensors, Aura Light takes lighting control to the next level. The smart components and systems enable us to simplify the installation

More information

MWS3A-PRM Product Guide

MWS3A-PRM Product Guide MWS3A-PRM Product Guide Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Installation 3 4 Fixing - Flush 4 5 Fixing

More information

VERSION 2 VISION LIGHTING CONTROLS

VERSION 2 VISION LIGHTING CONTROLS VERSION 2 VISION LIGHTING CONTROLS CONTENTS VISION 100 Stand alone controls 8-15 - Stand alone passive-infra-red and microwave devices - Latest high definition technology for improved coverage - Easy to

More information

Digital Addressable Lighting Interface

Digital Addressable Lighting Interface Digital Addressable Lighting Interface Who started DALI? It is supported by major manufacturers of ballasts Initially promoted by: And now including: BAG, Erco, Insta, Johnson controls, Magnetek, FCS lighting,

More information

UNIVERSAL LIGHTING OFFERS BREAKTHROUGHS FOR BOTH ANALOG AND DIGITAL DIMMING APPLICATIONS

UNIVERSAL LIGHTING OFFERS BREAKTHROUGHS FOR BOTH ANALOG AND DIGITAL DIMMING APPLICATIONS UNIVERSAL LIGHTING OFFERS BREAKTHROUGHS FOR BOTH ANALOG AND DIGITAL DIMMING APPLICATIONS SuperDim and AddressPro provide dimming versatility and time-saving convenience SuperDim Analog Dimming Ballasts

More information

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features Product Guide MWS3A-PRM Ceiling microwave presence/absence detector Overview The MWS3A-PRM microwave presence detector provides automatic control of lighting loads with optional manual control. The MWS3A-PRM

More information

Menlo³. Freedom to create with the power to comply

Menlo³. Freedom to create with the power to comply Menlo³ Freedom to create with the power to comply Contents Performance, Efficiency and Comfort p.4-7 Outstanding photometrics p.8-9 Aesthetic quality p.10-11 Choice range overview p.14-25 Making life easy

More information

EBMHS (standard & slim-line PSU)

EBMHS (standard & slim-line PSU) Product Guide EBMHS (standard & slim-line PSU) Miniature HS PIR Presence Detector (luminaire fitting) Overview The EBMHS series of miniature PIR (passive infrared) presence detectors provide automatic

More information

FR-A180 FR-A360. Occupancy detector. Use

FR-A180 FR-A360. Occupancy detector. Use 5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable

More information

DALI MSensor 02 Multi-sensor for DALI system

DALI MSensor 02 Multi-sensor for DALI system MSensor 02 Multi-sensor for system Product description Component of the comfortdim system ( standalone) With ambient light dependent control and motion detection Simple group assignment via rotary switch

More information

An-10 Wireless lighting control technology

An-10 Wireless lighting control technology An-10 Wireless lighting control technology An-10 Issue 1.1 An-10 Wireless Lighting Control 2 Welcome to CP Electronics CP Electronics has been designing and developing lighting control solutions for the

More information

An-10 Wireless lighting control technology

An-10 Wireless lighting control technology An-10 Wireless lighting control technology An-10 Issue 1.0 2 An-10 Wireless Lighting Control Welcome to CP Electronics CP Electronics has been designing and developing lighting control solutions for the

More information

Ceiling Microwave presence/absence detector 12-24V AC/DC

Ceiling Microwave presence/absence detector 12-24V AC/DC MWS3A-PRM-LV Product Guide Ceiling Microwave presence/absence detector 12-24V AC/DC Overview The MWS3A-PRM-LV Microwave presence detector provides automatic control of low voltage loads including lighting

More information

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features Product Guide PPAD-C-230V Ceiling PIR presence/absence detector Overview The PPAD-C-230V passive infrared presence detector provides automatic control of lighting loads with optional manual control. The

More information

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features Product Guide MWS6-PRM Ceiling microwave presence/absence detector Overview The MWS6-PRM microwave presence detector provides automatic control of lighting loads with optional manual control. The MWS6-PRM

More information

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDSPIR-HB-AD High bay PIR presence detector 1-10V dimming Overview The EBDSPIR-HB-AD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

The Power To Supply... All Your Electrical Products

The Power To Supply... All Your Electrical Products May 2016 ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and

More information

Standalone Presence Detectors

Standalone Presence Detectors Standalone Presence Detectors Innovation. Functionality. Simplicity. A Group brand Contents Infared Handsets UNLCDHS Professional programming/ commissioning LCD handset 4 UHS5 Compact programming/ commissioning

More information

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features Product Guide MPAD-C 12-24V Ceiling microwave presence/absence detector 12-24V AC/DC Overview The MPAD-C 12-24V Microwave presence detector provides automatic control of low voltage loads including lighting

More information

Trios Training Manual

Trios Training Manual Trios Training Manual Version 1.2, June 2002 TRIOS training-manual 1. 2 1 1. TRIOS SYSTEM INTRODUCTION... 2 The Trios Concept... 2 Trios Multi-functionality... 2 Trios Flexibility... 2 Trios Simplicity...

More information

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Product Guide EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM-VFC PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

GE Lighting. Lighting Controls. DALI Digital Lighting Controls GE ighting ighting Controls I Digital ighting Controls the I Protocol Multi-functional control of I-ready GE uminaires 1-1 to I converters available for analogue luminaires I CB Type 2 - complete programmable

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

The Power To Supply... All Your Electrical Products

The Power To Supply... All Your Electrical Products ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and omissions

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

11,1 30. Ordering data

11,1 30. Ordering data ID Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or I ballasts I/DSI output channels with adjustable negative offset

More information

MWS3 Ceiling Mount Microwave Occupancy Detector

MWS3 Ceiling Mount Microwave Occupancy Detector MWS3_0916/ISSUE1 MWS3 Ceiling Mount Microwave Occupancy Detector Description: the MW3SA offers a unique presence/absence detection capability by using an adjustable head. This incorporates an innovative

More information

Sensors Explained AUTOMATION

Sensors Explained AUTOMATION Sensors Explained Sensors Explained: Our range of PIR sensors and microwave presence detectors are designed to reduce the amount of time lighting is left on unnecessarily, for example if an area is unoccupied

More information

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC Product Guide EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC Ceiling PIR presence/absence detector 2 channel Overview The EBDSPIR-PRM-2CH PIR (passive infrared) presence detector provides automatic control of lighting

More information

Garbo. Calm mellow light from decorative wall, pendant and ceiling luminaires

Garbo. Calm mellow light from decorative wall, pendant and ceiling luminaires Garbo Calm mellow light from decorative wall, pendant and ceiling luminaires Garbo represents Thorn s latest thinking on how to combine a soft, mellow light within a discreet, classic and timeless luminaire

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features Product Guide VITMR-EBDSPIR-PRM PIR Presence/Absence Detector IR with Ceiling Rose Overview The VITMR-EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads.

More information

Energy Management. Lighting Control Solutions. To create flexible lighting networks

Energy Management. Lighting Control Solutions. To create flexible lighting networks Energy Management Lighting Control Solutions To create flexible lighting networks Greengate by Cooper Controls Offices Public Spaces Airports Stations Shopping Centres Libraries About Cooper Controls Cooper

More information

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel)

More information

LPCMPIRM65 & LPCMPIRDSI65

LPCMPIRM65 & LPCMPIRDSI65 Product Guide LPCMPIRM65 & LPCMPIRDSI65 Luminaire high mount PIR detectors Overview The LPCMPIR PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Instructions PRODUCT RANGE NEWLEC DALI OCCUPANCY DETECTOR PART NUMBER NL5701DALI

Instructions PRODUCT RANGE NEWLEC DALI OCCUPANCY DETECTOR PART NUMBER NL5701DALI PRODUCT RANGE NEWLEC DALI OCCUPANCY DETECTOR PART NUMBER NL5701DALI Occupancy Detector detection pattern 2.4 METRES FEATURES Presence and Absence Detection Options Automatic Daylight Harvesting Settable

More information

CHALLENGER 66 INDUSTRIAL

CHALLENGER 66 INDUSTRIAL CHALLENGER 66 INDUSTRIAL Features: Available in two lengths Single or twin LEDs Surface mounting IP66 (dust tight & strong water jet proof) IK10 (20 joule) shock resistance Corrosion resistant High performance

More information

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle GreenLight cooperative Product Specifications LED High Bay W LED High Bay GLC-ANHB-W- Linear Design System Light Efficacy >0 LPW Easy Installation & Maintenance IP6/ IP30(PIR) Five Years Warranty ETL,

More information

71 SKYTILE 36W 68 SKYTILE SENSE 76 SKYTILE SURFACE 5000 NEW NEW SKYTILE SKYTILE SKYTILE BASE LINEAR 28W SKYTILE SKYTILE SKYTILE SURFACE 6200

71 SKYTILE 36W 68 SKYTILE SENSE 76 SKYTILE SURFACE 5000 NEW NEW SKYTILE SKYTILE SKYTILE BASE LINEAR 28W SKYTILE SKYTILE SKYTILE SURFACE 6200 03 Panels NEW NEW 68 SENSE 70 28W 71 36W 72 BASE 73 LINEAR 75 SURFACE 4000 76 SURFACE 5000 77 SURFACE 6200 78 SURFACE 6600 Introducing Skytile Sense Skytile panel with integrated daylight harvesting or

More information

EBDSPIR-PRM-LV Product Guide

EBDSPIR-PRM-LV Product Guide EBDSPIR-PRM-LV Product Guide Ceiling PIR presence/absence detector 12-24V AC/DC Overview The EBDSPIR-PRM-LV PIR (passive infrared) presence detector provides automatic control of low voltage loads including

More information

B.E.G. LUXOMAT. Find the right detector.

B.E.G. LUXOMAT. Find the right detector. B.E.G. LUXOMAT Find the right detector www.beg-luxomat.com B.E.G. B.E.G. SMARTPHONE APP The new B.E.G. remote control app 92726 Rapid programming by smartphone The B.E.G. remote control app is the easiest

More information

DALI SPECIFICATION GUIDE

DALI SPECIFICATION GUIDE DALI SPECIFICATION GUIDE Page 2/3 contents Page 1. INTRODUCTION 6 2. DALI - THE STANDARD 6 2.1. Industry standard 6 2.2. Light control 6 2.3. Digital control 7 2.4. Switching in the electronic ballast

More information

luxcontrol DALI basicdim DGC Product Manual

luxcontrol DALI basicdim DGC Product Manual luxcontrol DALI basicdim DGC Product Manual Table of Contents 1. Scope of documentation 3 1.1. Copyright.................................................................................................................

More information

MANUFACTURED IN THE UK

MANUFACTURED IN THE UK The Mini-Max range of energy efficient bulkhead fittings are manufactured with a polycarbonate base and diffuser. Together with a poured gasket the Mini-Max leads vandal-resistant IP65 technology. With

More information

LPC3BSP65 & LPC3BDP65

LPC3BSP65 & LPC3BDP65 Product Guide LPC3BSP65 & LPC3BDP65 Batten mount PIR detectors Overview The LPC3B series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

ARGUS presence detectors. Move towards energy efficiency

ARGUS presence detectors. Move towards energy efficiency ARGUS presence detectors Move towards energy efficiency Energy consumption will dramatically increase within the next 20 years Solutions based on energy-efficient products are requested more and more 2

More information

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels MS3602CH 2 Channel Motion Sensor For Outdoor Use Wall & Ceiling Mounted Quick & Easy Installation 2 Channels Channel 2 Distance Wiring Diagram 220-240V ~ 50Hz 14A Max. (cosø=1) 3000W for incandescent load

More information

IQ Wave. Comfort without compromise

IQ Wave. Comfort without compromise IQ Wave Comfort without compromise 2 Comfort without compromise People are an organisation s most important and valuable asset. Regardless of what business you re in, people are an organisation s most

More information

C-Bus Application Note. Function Rooms and Ballrooms. Overview

C-Bus Application Note. Function Rooms and Ballrooms. Overview C-Bus Application Note Function Rooms and Ballrooms Overview A function venue or hotel will generally include large spaces purpose designed and built for holding functions. Function rooms and Ballrooms

More information

Lighting Management Solutions

Lighting Management Solutions Lighting Management Solutions Products & systems catalogue PUTTING A STOP TO ENERGY WASTE Putting a stop to energy waste CONTENTS Our vision...p3 Why implement Lighting Management?...p4 Requirements for

More information

Product Specifications

Product Specifications //206 00 VLN0 Product Specifications Nastro LED High Bay W Nastro LED High Bay EO-LN- EO-LN-T EO-LN-HV EO-LN-HVT Linear Design System Light Efficacy LPW Easy Installation & Maintenance IP6/ IP30(PIR) Five

More information

AddressPro Digital Dimming Technical Product Information

AddressPro Digital Dimming Technical Product Information AddressPro Digital Dimming Technical Product Information Installation Guidelines Control Wiring: Additional control wiring is required for AddressPro systems. The control wiring (violet and gray wires)

More information

Light Management Systems: Energy Savings.

Light Management Systems: Energy Savings. www.osram.com/lms Light Management Systems: Energy Savings. Complete LMS range for daylight-dependent and presence-dependent lighting. LMS ENERGY SAVINGS Good for our climate and good for your business.

More information

Canolux LED. Petrol Station Forecourt Luminaires

Canolux LED. Petrol Station Forecourt Luminaires Canolux LED Petrol Station Forecourt Luminaires Point source LEDs provide excellent opportunities to direct light accurately improving uniformity and reducing the electrical load. Well designed and manufactured

More information

Dublin airport - Dublin, Ireland

Dublin airport - Dublin, Ireland Dublin airport - Dublin, Ireland 604 Route LED 607 Route LED II 608 SYL Safe EMERGENCY 601 Emergency 80 Hammersmith Road - London, England Control Gear: Electronic Integral Sensor: Not applicable Emergency:

More information

PSFL , PSFL , PSFL , PSFL , PSFL

PSFL , PSFL , PSFL , PSFL , PSFL No. 345/ 09.01.2015, Edition No. 13, 1/11 Indoor luminaire PSFL-07 Clio PSFL-07-118, PSFL-07-126, PSFL-07-218, PSFL-07-226, PSFL-07-132, PSFL-07-142 Clio PSFL-07-118, PSFL-07-126, PSFL-07-218, PSFL-07-226

More information

Tri-level Control HF Sensor

Tri-level Control HF Sensor Daylight Monitoring TM Ambient daylight threshold Loop in Loop out Tri-level Control HF Sensor HC403VRC-KD Detached Version with Daylight Monitoring Applications Occupancy detector with tri-level dimming

More information

Product Specifications Dialog Room Controller* (*patent pending)

Product Specifications Dialog Room Controller* (*patent pending) 1 Product Specifications Dialog Room Controller* (*patent pending) 1. GENERAL 1.1. OVERVIEW 1.1.1. Provide a complete stand-alone, decentralized, low voltage, digital lighting control system for classrooms,

More information

SMARTER BUILDING. Busch-Presence detectors Energy saving the easy way

SMARTER BUILDING. Busch-Presence detectors Energy saving the easy way SMARTER BUILDING Busch-Presence detectors Energy saving the easy way 2 BUSCH-PRESENCE DETECTORS ENERGY SAVING THE EASY WAY Modern light management Saving costs with innovation Presence detectors automatically

More information

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER TOCR0 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER SAFETY PRECAUTIONS Be sure to switch off power source before installing. Make sure that the power wiring comes from circuit with an external 16A miniature

More information

Busch-Watchdog presence. Overview and applications of presence detectors.

Busch-Watchdog presence. Overview and applications of presence detectors. Busch-Watchdog presence Overview and applications of presence detectors. Do without the unnecessary. And save energy. Presence detectors automatically detect the presence of someone inside the room to

More information

Fully addressable lighting control system. Issue

Fully addressable lighting control system. Issue Fully addressable lighting control system Issue 3.2 Welcome to CP Electronics Leaders in energy saving controls for commercial, public sector and domestic environments Fully Addressable Lighting Control

More information

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent GI1DPC/B User Guide Single gang PIR Dimmer Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Night light mode* Scene setting and soft on/off* * only

More information

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version) Dimming Function MC00V (Standard Version) MC00V R (Reinforced Version) Dimming Introduction Automatic dimming when used in combination with 1-V dimmable LED drivers or ballasts. Built-in adjustable daylight

More information

B.E.G. Already heard of it? News

B.E.G.   Already heard of it? News B.E.G. Already heard of it? News 2014 Discover energy-savings potentials with OCCULOG* and convince your clients! How to save energy Knowing today about your energy-savings for tomorrow It is common knowledge

More information

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5 Lighting Control Sensor Daylight 2 Daylight+Motion 3 Daylight+Motion+Control 4 Daylight+Motion+Control IP67 5 Daylight SL01A Daylight+Motion+Control SM03A Daylight+Motion SM05 With the increasing interests

More information

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

The two type sensors are innovative and active motion dimmable LED drivers or ballasts. Dimming Function (Standard Version) R (Reinforced Version) Introduction Automatic dimming when used in combination with 1-V The two type sensors are innovative and active motion dimmable LED drivers or

More information

LEVEL SWITCH NP-3T DL v1.0 Installation instructions Order no E-no

LEVEL SWITCH NP-3T DL v1.0 Installation instructions Order no E-no LEVEL SWITCH v1. Installation instructions Order no. 13181 E-no. 13 6 81 Control that uses a light sensor Presence Power regulating up to two hours No presence Low level Blue knob1% Rest No presence Completely

More information

HF Motion Sensor Introduction

HF Motion Sensor Introduction HF Motion Sensor Introduction Completely built-in the lighting fixture, the motion sensor utilizes Doppler principle and RADAR technology to detect moving objects at certain speed & reflection surface,

More information

Lighting & Controls Motion & Presence Detectors

Lighting & Controls Motion & Presence Detectors Lighting & Controls Motion & Presence Detectors Let there be light But efficiently, please! Lighting control plays an important role in modern facility management. Not only to produce ideal living and

More information

Advanced Lighting For Office

Advanced Lighting For Office Advanced Lighting For Office Open-Plan Office Applications High-Density 1 This High-Density 1 lighting application module presents alternative energy effective lighting design options for open-plan offices.

More information