1 BEP Marine Gas Detector 600-GDRV Description BEP gas detectors use microprocessor control to ensure correct sensor sensitivity. The 600-GDRV Gas Detector uses the same sensor as the 600-GD and GDL, but the sensor is mounted in the front facia creating a stand alone unit. The unit is designed to be surface mounted at the lowest point in the vessel. The detector is equipped with a test button and a sensor status light. Features Power Supply: 10-32VDC Alarm Sensitivity: 20% LEL (Lower explosive limit) Detects Petrol fumes, LPG and CNG Current Draw: 70mA Dimensions 58mm x 44mm (2) sales@aquavolt.com.au 7/10/2012
2 600-GDRV 600 SERIES FUME DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS
3 Table of Contents 1 WARRANTY IMPORTANT CAUTIONS WHEN USING GAS SENSORS FEATURES SPECIFICATION FAULT DETECTION DIMENSIONS WIRING DIAGRAM INSTALLATION OPERATION TEST BUTTON INDICATOR DISPLAY... 7
4 1 Warranty The warranty of this BEP MARINE LTD product is for Two Years from date of sale to original purchaser. BEP MARIN assume the cost of removal or refitting of the product, or any other incidental cost that may arise, as the result of defe workmanship. Warranty will only be undertaken on equipment returned to either BEP MARINE LTD or their agent. The equipment w repaired at the discretion of either BEP MARINE LTD or its agents. As long as the equipment has neither been (1) Abused (2) Wrong connected (3) Contaminated due to neglect (4) Improper installation, (5) Used in violation of instructions supplied wit manufactured by BEP MARINE LTD. On return of equipment for warranty it must be accompanied with proof of purch tampered with. 2 Important It is the installer s sole responsibility to install and use this product in a manner that will not cause accidents, persona damage. Please follow the installation instructions supplied. If installation is not correct, the unit may not perform at it potential. If in doubt, consult your local BEP MARINE LTD dealer. BEP MARINE LTD disclaims all liability for any use that may cause accidents, damage or be in violation of any laws. Copyright 2005 BEP MARINE LTD. All rights reserved. 3 Cautions when using gas sensors 1. Exposure to silicone vapours If silicone vapours adsorb onto the sensor s surface, the internal sensing element maybe be coated, irreversibly sensitivity. Avoid exposure where silicone adhesives, hair grooming materials or silicone rubber/putty may be pre 2. Highly corrosive environment Exposure to corrosive materials such as H2S, SOx, Cl2, HCl, etc. for extended periods may cause irreversible damage to th sensor. 3. Water Sensor performance maybe adversely affected due to soaking, splashing or water condensing on the sensor sur salt water spray will adversely affected sensor performance. Light condensation under conditions of indoor usage should not pose a problem for sensor performance. 4. Freezing If freezing occurs on the sensor s surface irreversible damage may occur to the internal sensing element. 5. Usage in high density of gas Sensor performance maybe adversely affected if exposed to a high density of gas for a long period of time. 6. Explosive Limits Different combustible gasses have their own Lower Explosive Limits (LEL). Our gas sensors are calibrated again in Air. 7. False positive alarms False positive alarms can be caused by differing concentrations of various aerosols, perfumes, resins, epoxies, p alcohol, hydrogen, gases and fuels.
5 4 Features The GDRV fume detector offers the following features: Self testing capability Microprocessor control Single sensor mounted in front facia. Audible and visual alarms 5 Specification Voltage: Current: Alarm: 6 Fault Detection 10V-30V DC Total 350mA Max 20% LEL (Lower Explosive Limit) The nominal alarm point of the GDRV is 20% of the LEL (Lower Explosive Limit) of LPG/CNG in Air. In the event of a alarm activating, close the manual valve on your gas bottles and open hatches to ventilate the area. All fans and blow ventilate must be ignition-protected types. In the event of the sensor being contaminated or damaged the amber light will come on for the sensor. If the sensor the sensor could be damaged and will need to be replaced. In detecting LPG the sensor can also detect hydrocarbons in other products such as cleaners and strong adhesives, nuisance alarms. See section 3 - Cautions when using gas sensors for more details.
6 7 Dimensions
7 8 Wiring Diagram
8 9 Installation For ease of operation, the unit should be mounted in a convenient position close to your gas appliances and in a pos control head can be seen and heard easily. The unit can be either surface mounted or recessed into a 2.5mm panel. For LPG and Petrol fumes, which are heavier than air, mount the sensor in a low dry position where the gas is lik sensor must be mounted clear of bilge water. NOTE: If the sensor gets wet then the sensor becomes inoperable and must be replaced. For CNG, which is lighter than air, mount the unit just below ceiling height but not above cooking or heating appli 10 Operation On applying power to the unit, the unit goes through a test cycle. This will take approximately 45 seconds. During this is being cleaned and tested, at this time there will be a slow beep from the audible alarm and all the lights will flash a end of this period the pulse of the beeper and light will increase, if the unit senses that the environment is clear then safe mode. The beeper will turn off and the sensor light will change to green. 11 Test Button When operated in normal operation it will - Sounds the keyboard beeper Turn light red Pressing the switch again cancels the above. 12 Indicator Display SENSOR #1 Green: Amber: Red: Sensor on safe, no fumes, no beeping Sensor fault, slow beeping Alarm. Gas present, fast beeping AUDIBLE ALARM SOUNDS Warming up: Alarm: Fault: Medium slow, all lights flash amber Fast, sensor lights red Slow, sensor lights amber
BEP Marine Gas Detector FD-2
BEP Marine Gas Detector FD-2 Description BEP gas detectors use microprocessor control to ensure correct sensor sensitivity. The FD-2 Gas Detector is an economical gas detector with one remote mounted sensor..
More informationPropane Fume Detection System
Propane Fume Detection System Single Channel Systems P-1B-R (Black, Round) P-1C-R (Chrome, Round) Owner s Manual & Installation Instructions Read and comply with all instructions, warnings and limitations
More informationan ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors
TECHNICAL INFORMATION FOR TGS83 Technical Information for Combustible Gas Sensors an ISO900 company Figaro TGS 8-series sensors are a type of sintered bulk metal oxide semiconductor which offer low cost,
More informationPropane Fume Detection System With Solenoid Valve Control
Propane Fume Detection System With Solenoid Valve Control Single Channel Systems P-1BS-R (Black, Round, Solenoid Control) P-1CS-R (Chrome, Round, Solenoid Control) Dual Channel System P-2BS-R (Black, Square,
More informationMacurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference
Macurco HD-11 Hydrogen Gas Detector User Instructions Important: Keep these User Instructions for reference 2 TABLE OF CONTENTS GENERAL SAFETY INFORMATION 4 INTENDED USE 4 LIST OF WARNINGS AND CAUTIONS
More informationPropane Fume Detection System With Solenoid Valve Control
Propane Fume Detection System With Solenoid Valve Control Single Channel Systems P-1BS-R (Black, Round, Solenoid Control) P-1CS-R (Chrome, Round, Solenoid Control) Dual Channel System P-2BS-R (Black, Square,
More informationModel LP USER S MANUAL AND INSTALLATION INSTRUCTIONS
Atwood Mobile Products LLC 1120 North Main Street Elkhart, IN 46614-3203 USA & Canada 1-866-869-3118 Internet: http://www.atwoodmobile.com Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS TESTED TO
More informationKAB Gas Alarm Operation Manual
KAB Gas Alarm Operation Manual Henan Hanwei Electronics Co.,Ltd ISO9001-2008 Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use gas detector before
More informationMacurco HD-11 Hydrogen Gas Detector
Macurco HD-11 Hydrogen Gas Detector User Instructions Important: Keep these User Instructions for reference TABLE OF CONTENTS GENERAL SAFETY INFORMATION 3 Intended Use 3 List of Warnings and Cautions 3
More informationG D G D. Handbook. Handbook. Warranty
Warranty Each unit is carefully tested and adjusted at the factory before shipping and is warranted for one full year against original defects in materials or workmanship. This warranty does not include
More informationKAE Gas Alarm Operation Manual
KAE Gas Alarm Operation Manual Henan Hanwei Electronics Co.,Ltd ISO9001-2008 Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use gas detector before
More information3 Macurco Carbon Monoxide Detector CM-16A
3 Macurco Carbon Monoxide Detector CM-16A User Instructions for 3M Macurco Carbon Monoxide Detector (CO) CM-16A FOR MORE INFORMATION In United States, contact: Website: www.3m.com/occsafety Technical Assistance:
More informationSBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present
SBS-H2 Hydrogen Gas Detector Kit For battery charging rooms and other areas where hydrogen gas may be present INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS Protects Life, Property, and Profits Compliant
More informationGD Series Gas Alarm Operation Manual
GD Series Gas Alarm Operation Manual Hanwei Electronics Co.,Ltd Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use the product before reading this
More informationPre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit
Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design N56 W16665 Ridgewood Drive Menomonee Falls, WI 53051 SBS-H2 Hydrogen Gas Detector Kit For battery charging rooms and other areas where
More informationDocument No
CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 CARBON MONOXIDE DETECTOR MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Document No. 01-2510-02 MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Page 1
More informationTC100N. Fixed Gas Detector Operation Manual
TC100N Fixed Gas Detector Operation Manual Safety Information Before using this device, please carefully read the following safety information: After opening the packing box, please check if there is any
More informationG.O.L.D. GAS OPERATIONS LEAK DETECTION USER MANUAL
G.O.L.D. GAS OPERATIONS LEAK DETECTION USER MANUAL Part Number: MAN-0045-00 Rev1 August 2003 Copyright 2003 Net Safety Monitoring Inc. Printed in Canada This manual is provided for informational purposes
More informationGASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL
GASGUARD H2S EXP Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used
More informationGG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual
GG-LEL2 COMBUSTIBLE GAS SENSOR Installation and Operation Manual 2 GG-LEL2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration
More informationDeluxe Discharge Alarm
Deluxe Discharge Alarm DU-RBH-01 (Round, Black, Horn) DU-RCH-01 (Round, Chrome, Horn) Owner s Manual & Installation Instructions Read and comply with all instructions, warnings and limitations before installing,
More informationQAS-101 SERIES SINGLE CHANNEL CONTROLLERS
QAS-101 SERIES SINGLE CHANNEL CONTROLLERS INSTALLATION OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749, RICHMOND, ONTARIO, CANADA. K0A 2Z0 PHONE: (613) 838-4005
More informationUser s Manual For Model Aero-551 (Rev. Orig.)
User s Manual For Model Aero-551 (Rev. Orig.) Document: 551-100 REV A LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION APPROVED Orig. 1 thru 5 12/4/06 Initial Release ASH VIJ A 2 and 3 10/22/06 Deleted
More informationGASGUARD LEL 3 OPERATING & INSTALLATION MANUAL
GASGUARD LEL 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GasGuard LEL 3 Operating and Installation Manual 2 Table of Contents 3GasGuard LEL Operating and Instruction Manual General description. 4
More informationProcess Control PIP PCEA001 Fixed Gas Detection Guidelines
November 2015 Process Control PIP PCEA001 PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from the technical
More informationModel GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com
Model GD-3300 Combustible Gas Leak Detector Instruction Manual reedinstruments com Introduction The Combustible Gas Leak Detector has a 16 gooseneck probe to find leaks in hard-to-reach areas. It s adjustable
More information6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment
CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES ---------------------------------------- 2 3. SPECIFICATION --------------------------------- 3 4. OPERATION GUIDE ---------------------------
More informationMACURCO INC. CONTROLLERS & CARBON MONOXIDE DETECTORS SS103-3A, SS103-10A SS102H, SS102HC-1 INSTALLATION & OPERATING INSTRUCTIONS
MACURCO INC. CONTROLLERS & CARBON MONOXIDE DETECTORS SS103-3A, SS103-10A SS102H, SS102HC-1 INSTALLATION & OPERATING INSTRUCTIONS WWW.MACURCO.COM NOTE: SUGGESTED WIRE SIZE VS LENGTH OF WIRE BETWEEN EACH
More informationGASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL
GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard H 2-1% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation..
More informationModel C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments
Model C-380 Refrigerant Leak Detector Instruction Manual reedinstruments www 1-877-849-2127 info@reedinstruments. www.reedinstruments. Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument
More informationMacurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions
Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions Important: Keep these User Instructions for reference 2 TABLE OF CONTENTS GENERAL SAFETY
More informationSBS-H2 Hydrogen Gas Detector Kit
SBS-H2 Hydrogen Gas Detector Kit For battery charging rooms and other areas where hydrogen gas may be present INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Protects Life, Property and Profits Electrical
More informationINSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715
INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model ABM - 715 M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: 800-831-1525 Mazeppa, MN 55956 Fax : (507)843-4953
More informationincontrol Systems Inc. Flame and Gas Detection
incontrol Systems Inc. Flame and Gas Detection Our flame and gas detectors are globally certified to the latest product approval standards Wherever toxic or combustible gases are part of an industrial
More informationIMR IX176 Portable Gas Detector User Manual
IMR Portable Gas Detector User Manual Read this manual carefully before using this device. (727) 328-2818 / (800) RING-IMR Fax: (727) 328-2826 www.imrusa.com Ver. 1.0A4 CONTENTS SERVICE GUIDELINES... 3
More information169MHz Telecare Devices. Gas Detector
169MHz Telecare Devices Gas Detector Compatible with Reach at-home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems Alarm at 10% of LEL (Lower Explosive Limit) 85dB @ 1m
More informationNG-9B NATURAL GAS ALARM
User Manual NG-9B NATURAL GAS ALARM Detects gas from household appliances NG-9B 1 Do not ignore any warning from your Natural Gas Alarm! Vacate the property and immediately call the UK Gas Emergency Service
More informationMODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR
MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749 RICHMOND, ONTARIO CANADA
More informationAT-G-SENSE Gas Sensing System
AT-G-SENSE Gas Sensing System INSTALLATION & OPERATING MANUAL INSTALLATION INSTRUCTIONS Open the AT-G-SENSE by undoing the two screws. Remove metal faceplate, turn over and check connection terminals (maximum
More informationINSTRUCTION MANUAL CD Fax: (503)
INSTRUCTION MANUAL CD200 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com Introduction International Symbols The CD200 has a long, slim gooseneck probe and a bright LED tip light
More informationOPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)
OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252) What is Carbon Monoxide? Carbon Monoxide (CO) is a colorless,
More informationCOMBUSTIBLE GAS LEAK DETECTOR PEN
COMBUSTIBLE GAS LEAK DETECTOR PEN USER S MANUAL PNG1 Please read this manual carefully and thoroughly before using this product. Test Equipment Depot - 800.517.8431 99 Washington Street Melrose, MA 02176
More informationA series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.
Belonging to Made in Italy GS911K Gas Detector GS911K Using the catalytic sensor inside it, the GS911K detector detects the presence of explosive gas such as: Methane, LPG, with trip sensitivity calibrated
More informationWIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions
Wireless Gas Detection & Shut Off System - User Manual & Instructions Please read and follow these instructions prior to installation of the system as correct installation is critical to the performance
More informationRK-05 Combustible Gas Transmitter Operator s Manual
65-2405RK-05 Combustible Gas Transmitter Operator s Manual Part Number: 71-0180RK Revision: 0 Released: 2/16/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction
More informationGASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL
GASGUARD Cl 2 Chlorine Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard Cl 2 Operating and Instruction Manual General description. 4 Installation..
More informationGG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual
GG-H2S HYDROGEN SULFIDE GAS SENSOR Installation and Operation Manual 2 GG-H2S Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by
More informationDESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR
DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR 70086 The information in this doucment is applicable to sensors built in September, 2008 or later (Firmware 3.0) The information and technical
More informationFPX103C. Dual Loop Auto/Manual Fire Control Panel. Technical Manual
FPX103C Dual Loop Auto/Manual Fire Control Panel Technical Manual FPX103C Auto DUAL LOOP AUTO/MANUAL FIRE CONTROL PANEL Iss 1.0 SUMMARY: Dual detection loops with full fault monitoring. Automatic extinguisher
More informationNGD8800 USER S MANUAL
NGD8800 USER S MANUAL COMBUSTIBLE GAS DETECTOR Please read this manual carefully and thoroughly before using this product. CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES -----------------------------------------
More informationGG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual
GG-CO-EXP CARBON MONOXIDE SENSOR Installation and Operation Manual 2 GG-CO-EXP Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by
More informationGas Fire Patio Heater Q9
Gas Fire Patio Heater Q9 Instruction Manual Please read the manual BEFORE you unpack or install the fire TABLE OF CONTENTS Warning 3 Getting Started 4 What s Included 5 Assembly Procedures 6 Product Drawing
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Combustible Gas Leak Detector Instruction and Operation Manual Page 2 Detector
More informationUser s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM
User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info HHAQ-109 Portable Multi-gas Detector User Guide Thanks for our using our products. Before
More informationSetup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2
Setup instructions 1. Connection terminal, output signal and device connection Honeywell GAS DETECTOR Overview The autonomous gas sensor (hereinafter referred to as the sensor) is a home device for detecting
More informationINSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700
INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model ABM - 700 M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: 800-831-1525 Mazeppa, MN 55956 Fax : (507)843-4953
More informationII 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA
SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING II 2 G Ex ib IIB T3 IP20 PENDING (USA) Class 1, Division 1, Groups C and D, T3 Suitable for
More informationSENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20
SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex II3G Ex ic llb T3 IP20 PENDING (USA) Class 1, Zone 2, AEx nl llb T3 PENDING (Canada) Class
More informationSENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector
SENSIT HXG-2 Instruction Manual For use with combustible gases Gas Leak Detector CLASSIFIED 7WA6 Approved UL913, For Class 1, Division 1, Groups C & D hazardous locations when used with alkaline batteries.
More informationGASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL
GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a
More informationC0-210 Carbon Monoxide Probe
C0-210 Carbon Monoxide Probe Instruction Sheet Introduction The CO-210 Carbon Monoxide Probe (hereafter referred to as the Probe ) detects the presence of carbon monoxide (CO) and measures concentrations
More informationGG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual
GG-NO2 NITROGEN DIOXIDE GAS SENSOR Installation and Operation Manual 2 GG-NO2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by
More informationSmoke Alarm User s Manual
V-MUL-007-D(A0) Smoke Alarm User s Manual Please read and save this manual PHOTOELECTRIC SMOKE ALARM( HUSH FEATURE) MODEL: VST-S588H Class II Apparatus Photoelectric smoke alarms are generally more effective
More informationGas Fire Patio Heater Lhotse-817
Gas Fire Patio Heater Lhotse-817 Instruction Manual Please read the manual BEFORE you unpack or install the fire TABLE OF CONTENTS Warning 3 Getting Started 4 What s Included 5 Assembly Procedures 6 Product
More informationGL-CO-RFG Channel Gas Leak Alarm System
Four Elms Road Edenbridge Kent TN8 6AB UK Features & Benefits Remote sensors for natural gas, LPG and CO 1 x SPST relay outputs DIN-rail as standard, panel mounting kit available Adjustable alarm thresholds
More informationFor cleaning machines, parts & supplies click/visit Electrolux Home Care Products Ltd.
Sanitaire 1.5 GALLON Carpet Spotter SC6075A Part No. SC6075A Rev 2 (9/13) Owner s Guide IMPORTANT Do not return this product to the store. Call 1-800-800-8975* Monday - Friday 8:00 AM to 7:30 PM and Saturday
More informationOperation and Maintenance Manual
Operation and Maintenance Manual GDS-48 Remote Bridge Sensor for Combustible Gases AUTHORIZED DISTRIBUTOR: GasDetectorsUSA.com - Houston, Texas USA sales@gasdetectorsusa.com - 832-615-3588 CAUTION: FOR
More informationCO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL
OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel mount and Remote Detectors (R) (353 and 353R) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION
More informationSENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)
WARRANTY AND REPAIR POLICY Your SENSIT HXG-2d instrument is warranted to be free from defects in materials and workmanship for a period of two years after purchase (excluding sensor, calibration and batteries).
More informationUser s Manual & Safety Instructions Read Carefully Before Use
Thank you for choosing Sunnydaze Decor. If you have any questions, comments or concerns please feel free to contact us by phone at: 888-881-4668, by email: customerservice@serenityhealth.com, or you could
More informationOWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.
OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) (353-101 and 353-201) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION
More informationSafety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR
Safety Siren Carbon Monoxide, Propane & Methane DETECTOR Owner's Manual Model Number HS80004 HS80104 HS80204 HS80504 Copyright, 1996 All Rights Reserved Family Safety Products, Inc. 2879 Remico SW Grandville,
More informationFPX103C Auto DUAL LOOP AUTO/MANUAL FIRE CONTROL PANEL Iss 1.0
FPX103C Auto DUAL LOOP AUTO/MANUAL FIRE CONTROL PANEL Iss 1.0 SUMMARY: Dual detection loops with full fault monitoring. Automatic extinguisher operation after shutdown. Double knock automatic activation
More informationCO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.
1951 E. AIRPORT DRIVE Date: 8-20-2004 CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 OWNERS MANUAL CARBON MONOXIDE DETECTOR MODEL 452-201 REMOTE UNIT MODEL 452-201 OWNERS MANUAL Page 1 of 22 INTENTIONALLY
More informationRK Transmitter Technical Notice
65-2450RK Transmitter Technical Notice Although this Operator s Manual was written for the 65-2400RK combustible gas LEL transmitter, the operational instructions are the same for the 65-2450RK hydrogen
More informationRK Combustible Gas Transmitter Operator s Manual
65-2400RK Combustible Gas Transmitter Operator s Manual Part Number: 71-0060RK Revision: C Released: 1/31/13 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationQAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR
QAS-10000 SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR INSTALLATION, OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749, RICHMOND, ONTARIO, CANADA. K0A
More informationIR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance
IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The
More informationSENSIT HXG-2d Combustible Gas Detector
INSTRUCTION MANUAL SENSIT HXG-2d Combustible Gas Detector Read and understand instructions before use. 710183 UL 913 Intrinsically Safe for Use in Class I, Groups C and D, T3 Hazardous Locations For use
More informationGas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.
Gas Safety Products Merlin Gas Detectors Read these instructions carefully before operating or servicing. Installation, operating and maintenance S&S Northern Ltd 1 The unit should be installed by a competent
More information3M Oldham OLCT 100. Description. Fixed Gas Detector
Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions,
More informationApplication Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES
FLAME AND GAS DETECTION FOR LNG FACILITIES Liquefied natural gas (LNG) is a generic name for liquefied hydrocarbon gas composed primarily of methane. When natural gas is cooled to approximately -260 F,
More informationRK / RK Methane Detector Operator s Manual
61-1006RK / 61-0192RK Methane Detector Operator s Manual Part Number: 71-0228RK Revision: 0 Released: 10/29/18 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationGASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL
GASGUARD NH 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard NH 3 Operating and Instruction Manual General description. 4 Installation.. 4
More informationRK-03 Hydrogen Detector Operator s Manual
61-1001RK-03 Hydrogen Detector Operator s Manual Part Number: 71-0371 Revision: P1 Released: 5/26/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.
More informationGG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual
GG-NH3 AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration
More informationMGC Dock User s Manual
Operator s Manual Contents Warnings Statements/Avertisseement... 3 READ FIRST BEFORE OPERATION... 3 Basic Operation... 4 Clip Dock Components... 4 LEDs... 4 Operation... 5 Turning the Clip Dock On and
More informationINSTALLATION AND OPERATING MANUAL
dickinson since 1932 MODEL 00-NEW-P12000 INSTALLATION AND OPERATING MANUAL Manufactured by: Dickinson Marine (1997) Ltd, 407-204 Cayer Street, Coquitlam, British Columbia, Canada V3K 5B1 www.ahoycaptain.com
More informationCatalytic Flammable Gas Sensor. (Model: MC105B) User s Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.
Catalytic Flammable Gas Sensor (Model: MC105B) User s Manual Version: 1.3 Valid from: 2014-05-01 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen
More informationTower Ceramic Heater
Instruction Manual Tower Ceramic Heater M odel : SH-1508 It is important that you read these instructions before using your new heater and we strongly recommend that you keep them in a safe place for future
More information169MHz Telecare Devices Gas & Carbon Monoxide Detector
169MHz Telecare Devices Gas & Carbon Monoxide Detector Compatible with Reach at-home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems Gas alarm activates at 10% of Lower
More informationMEMS Carbon Monoxide Gas Sensor. (Model No.:GM-702B) Manual. Version: 1.1. Valid from: Zhengzhou Winsen Electronics Technology Co.
MEMS Carbon Monoxide Gas Sensor (Model No.:GM-702B) Manual Version: 1.1 Valid from: 2017.11.23 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen
More informationSUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS
SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS READ THESE INSTRUCTIONS BEFORE PLANNING YOUR INSTALLATION PLEASE READ AND SAVE THESE INSTRUCTIONS: DO NOT CONNECT POWER
More informationReacti-Therm I and III Heating/Stirring Modules
INSTRUCTIONS Reacti-Therm I and III Heating/Stirring Modules TS-18821 TS-18823 Number TS-18821 TS-18823 Description Reacti-Therm I Heating/Stirring Module (single block) Reacti-Therm III Heating/Stirring
More informationGASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL
GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard NH 3 2% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6
More informationWireless Interlink Smoke Alarm + 10 Year Life
User Manual Wireless Interlink Smoke Alarm + 10 Year Life WST-630 Please retain this user manual for future reference 1 CONTENTS Introduction 3 Sensor technology 3 Application 3 Positioning 4 How to install
More informationOLC(T) 100 FIXED GAS DETECTOR
Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The
More informationOWNER S MANUAL. Remote Mobile Security System. Models: PL50 PL60
Remote Mobile Security System OWNER S MANUAL Models: PL50 PL60 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
More informationUser Guide. for the Beacon ProActTM 200 System
TM User Guide for the Beacon ProActTM 200 System BEACON recommends that this product, like all sump pumprelated products, be installed by or under the supervision of a professional plumbing contractor.
More information4P-90 CiTipeL Combustible Gas Sensor Part Number: PM
Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance 4P-90 CiTipeL Combustible Gas Sensor Part Number: PM143-000 Performance
More information