Introducing Corcom DB Series

Size: px
Start display at page:

Download "Introducing Corcom DB Series"

Transcription

1 Introducing orcom Series

2 orcom Series KY TURS ompact connector for high-current applications Reliable performance in a compact assembly 60 current rating Polarized mating scheme asy customer termination of power source Plug and receptacle available preterminated with standard wire lengths PPLITIONS Tyco lectronics has expanded the orcom product line with a new power inlet filter. vailable in four levels of filtering and an unfiltered version, these inlets are designed to accept up to 60 amps of current at 150 volts (UL/S) and 120 volts (TUV) in the filtered versions and 300 volts or in the unfiltered version. iltered versions include the basic clean-up J style through the higher performing style and X style which provides up to 68d insertion loss within the 150kHz to 30Mhz frequency range. The style uses feedthrough capacitors for improved high-frequency performance. Power input terminals are Tyco lectronics #4 WG lcon drawer style contacts. The filters load sides come prewired with #6 WG hi-flex stranded wire. The unfiltered plugs and receptacles are available with pre-terminated, hi-flex wire of various lengths. PPLITIONS Telecom equipment, utomotive equipment, ata communications, Power distribution panels STNR N SPS RI ilter - UL1283 Recognized - S ertified 22.2 No.8/TUV ertified N (ilter) onnector System - UL1977 Recognized/S ertified (through UL) - TUV ertified N61984 WRNING : This is not approved for hot swap or current interruption in applications. oing so will result in irreparable damage to contact. PPLITION TOOLING (UnterminT ontacts Only) Insertion/xtraction tool recommended : (for R/P only) No hand tool available. Must crimp per Tyco lectronics application spec : rimp tool : M22520/23-01 Indenter head : M22520/23-04 Locator : M22520/23-11 SSORIS onnector system locking kit available. (ontact orcom) Note : Tool required to disengage mated connector pair when using locking kit. Tyco lectronics I orcom Series

3 PROUT ORING 60R : onnector housing, receptable with retention clips 60P : onnector housing, plug with rention clips 60PL1 : Mating connector plug terminated with 1 foot cable 60PL3 : Mating connector plug terminated with 3 foot cable 60PL9 : Mating connector plug terminated with 9 foot cable 60RL1 : Receptacle terminated with 1 foot cable 60RL3 : Receptacle terminated with 3 foot cable 60J8 : ilter assembly with 6 inch wire leads 608 : ilter assembly with conventional wire leaded capacitors 608 : ilter assembly with feedthrough capacitors 60X8 : High performance filter assembly ase imensions Part No. (max) (max) 60J X RL 1.22* * 29.99* PL 1.695* * 23.62* * imensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. imensions are shown for reference purposes only. Specifications subject to change. WRNING : This is not approved for hot swap or current interruption in applications. oing so will result in irreparable damage to contact.

4 orcom Series S IMNSIONS continued 60J8 608/ Max. 6.0 Min (ref) Min (ref) onnector ia an ia. xtra lexible Label lack (-V) Label lack (-V) #6-32 Thread #4-40 Thread (2x) xtra lexible 60X8 60RL Min (ref) #6-32 Thread #4-40 Thread (2x) Label lack (-V) xtra lexible ia. 2x lack (-V) xtra lexible 60RL/60J8 Panel utout 60PL R ia. (2x) 3.50 R ia. (2x) ront Mount Panel utout Tolerance ± Rear Mount Panel utout Tolerance ±.005 lack (-V) xtra lexible WRNING : This is not approved for hot swap or current interruption in applications. oing so will result in irreparable damage to contact. orcom Series I Tyco lectronics

5 lectrical schematics -to-ground in 50 ohm circuit (requency MHz) Part Number J Part Number X to-line in 50 ohm circuit (requency MHz) Part Number J Part Number X J8 60X8 -V (lack) -V (lack) 608 -V (lack) 608 -V (lack) WRNING : This is not approved for hot swap or current interruption in applications. oing so will result in irreparable damage to contact. orcom Series I Tyco lectronics

6 OR MOR INORMTION Technical Support orcom Phone Internet: -mail: US: +1 (800) anada: +1 (905) Mexico & entral merica: +52(0) South merica: +55 (0) Germany: +49 (0) UK: +44 (0) rance: +33 (0) Netherlands: +31 (0) hina: +86 (0) Tyco lectronics orporation Harrisburg, P tycoelectronics.com 2009 Tyco lectronics orporation IS P 2.5M 9/2009 OROM, LON, T logo and Tyco lectronics are trademarks. Other products, logos, and ompany names mentioned herein may be trademarks of their respective owners. While Tyco lectronics has made every reasonable effort to ensure the accuracy of the information in this catalog, Tyco lectronics does not guarantee that it is error-free, nor does Tyco lectronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco lectronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco lectronics expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. onsult Tyco lectronics for the latest dimensions and design specifications.

Introducing Corcom CU Series 1U Height Power Entry Modules

Introducing Corcom CU Series 1U Height Power Entry Modules Introducing orcom U Series 1U Height Power Entry Modules orcom U Series 1U Height Power Entry Modules KEY ETURES ompact 1U (1 3/4 ) Design 115* iltered and Unfiltered SPST Switch Shrouded Quickonnect Terminals

More information

Quick Reference Guide.050 Centerline Micro-MaTch Connector Series

Quick Reference Guide.050 Centerline Micro-MaTch Connector Series Quick Reference Guide.050 enterline MicroMaTch onnector Series The Tyco Electronics MicroMaTch connector family, with its contact spacing of 1.27mm, offers a variety of wiretoboard and boardtoboard interconnections.

More information

Introducing Hermaphroditic Blade and Receptacle Connector

Introducing Hermaphroditic Blade and Receptacle Connector Introducing Hermaphroditic Blade and Receptacle Connector Wire-to-Board, Board-to-Board and Dust Cover Hermaphroditic Blade and Receptacle Connector : Wire-to-Board KEY FEATURES Available in 2, 4, and

More information

Introducing SlimSeal SSL Connector

Introducing SlimSeal SSL Connector Introducing SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These connectors provide low power, sealed

More information

Introducing Low Voltage DC Grid Interconnects

Introducing Low Voltage DC Grid Interconnects Introducing Low Voltage DC Grid Interconnects LVDC Grid Interconnects KEY FEATURES Power Feed Cable Assembly Power Feed Connectors are available upon special request comprising of the following: - Universal

More information

Quick Reference Guide Barrier Strips

Quick Reference Guide Barrier Strips Quick Reference Guide Barrier Strips Barrier strip style terminal blocks from Tyco Electronics are available in 3 main categories: dual-barrier, tri-barrier, and double row. Each category of barrier strip

More information

Introducing Inverted SMT Thru Board Connector

Introducing Inverted SMT Thru Board Connector Introducing Inverted SMT Thru Inverted SMT Thru KEY FEATURES Available in 2 through 6 positions Eliminates wire dress management issues with discreet wire leads around the surface of the LED pc board Accepts

More information

SOLARLOK Interconnection System Installation Manual

SOLARLOK Interconnection System Installation Manual SOLARLOK Interconnection System 1. Safety Note! n The SOLARLOK connector is to be used only to interconnect firmly fixed cables. n Do not disconnect under electrical load! n Electrical current path should

More information

Introducing Solar Identification Labels

Introducing Solar Identification Labels Introducing Solar Identification Labels Solar Identification Labels KEY FEATURES Recommended for use in identification of DC Disconnects and Inverters. For use on painted smooth metal and textured metal

More information

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment RoHS Ready UMCC Ultraminiature Coax Connector & Cable Assembly Series DESCRIPTION Tyco Electronics introduces the Ultraminiature Coax Connector and Cable Assembly series products. The UMCC series is an

More information

Z-PACK TinMan 85 ohm Connector Overview

Z-PACK TinMan 85 ohm Connector Overview Z-PACK TinMan 85 ohm High Speed Backplane Connector Z-PACK TinMan 85 ohm Connector Overview Product Facts 10+ Gbps performance 85 ohm impedance for differential pair configuration 5 pair version offers

More information

Standard and Customized Hand Tool Kits

Standard and Customized Hand Tool Kits Standard and Customized Hand Tool Kits Application Tooling and Equipment Portfolio Applicators Board Processing Equipment Crimp Machines and Equipment Equipment for Electrical Testing FFC-FPC Equipment

More information

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies APPLICATIONS High Speed I/O Multiple Channels Interconnects Switches for Fibre Channel and InfiniBand Standards TECHNICAL DOCUMENTS

More information

Pin, Spool & Strain Insulators

Pin, Spool & Strain Insulators Pin, Spool & Strain Insulators TE Connectivity Pin, Spool & Strain Insulators Pin, SpooL, Strain Insulators TE Energy rounds out the insulator offering to include spool, pin and strain insulators. TE s

More information

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies APPLICATIONS High Speed I/O Multiple Channels Interconnects Switches for Fibre Channel and Infiniband Standards Internal and External

More information

AMP SUPERSEAL 1.5 SERIES Connectors

AMP SUPERSEAL 1.5 SERIES Connectors Introduction Tyco Electronics has developed the MP SUPERSEL 1.5 SERIES Connector family to meet the increasing requirements for reliability and water proofness. MP SUPERSEL 1.5 SERIES Connector exceed

More information

LOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE

LOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE LOW POWER AND SIGNAL APPLICATION GUIDE MORE SOLUTIONS TE Connectivity s (TE) extensive connector and sensor solutions provide the essential connectivity you need for your daily interactions at home and

More information

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution Undercarpet Cabling Products TE Connectivity Enterprise Networks Warranty Power Distribution Product Coverage* TE Connectivity warrants that all Undercarpet cabling system products within this catalog

More information

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS YOUR UNDERGROUND CONNECTION Cable accessories provide a critical backbone to today s complex underground

More information

PlanarMag Product Technology

PlanarMag Product Technology Technical Data APPLICATIONS Enterprise switches and routers Low profile Laptop, Netbook, e-readers SMB (small medium business) switches and routers Wireless router TV/DVRs/STB IP Phones and cameras Video

More information

Quick Reference Guide: Connectors for Mobile Devices

Quick Reference Guide: Connectors for Mobile Devices Quick Reference Guide: Connectors for Mobile evices Tyco Electronics supplies a unique expertise for today's and tomorrow's mobile equipment applications, including cellular phones, mobile media players,

More information

High Speed Fine Pitch Connectors (MICTOR, MICTOR SB, Micro-Strip and STEP-Z Interconnection Systems)

High Speed Fine Pitch Connectors (MICTOR, MICTOR SB, Micro-Strip and STEP-Z Interconnection Systems) 4 Need more information? all Technical Support at the numbers listed below. Technical Support is staffed with specialists well versed in all Tyco Electronics products. They can provide you with: Technical

More information

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO Elastomeric MV Terminations TFTI/TFTO for and Applications for Polymeric Cables up to 42 kv Push-on and Cold-shrink

More information

Application Specification MAG-MATE* Poke-In Tab Terminals

Application Specification MAG-MATE* Poke-In Tab Terminals Application Specification MAG-MATE* 114-2050 Poke-In Tab Terminals 30 MAR 07 Rev G1 NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters

More information

Reliable solutions for electrified railway systems

Reliable solutions for electrified railway systems Reliable solutions for electrified railway systems 1 2 3 Insulation Enhancement System Insulation Enhancement System 1. Raychem MVLC: (Medium Voltage Line Cover) Provides insulation for catenary, droppers

More information

Gas Discharge Tubes GTCX25-XXXM-R02 Series

Gas Discharge Tubes GTCX25-XXXM-R02 Series Raychem Circuit Protection 5mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines

More information

High Density Optical In-Line Dry-Mate Connector (ILC) High Performance Multichannel Fiber Optic Connectors

High Density Optical In-Line Dry-Mate Connector (ILC) High Performance Multichannel Fiber Optic Connectors DEUTSCH High Density Optical In-Line (ILC) High Performance Multichannel Fiber Optic Connectors DEUTSCH High Density Optical In-Line High Pressure/High Temperature Performance Developed from subsea and

More information

Signal Connectors for Topside and Subsea Applications

Signal Connectors for Topside and Subsea Applications Signal Connectors for Topside and Subsea Applications Withstand the Hazards of Offshore DEUTSCH signal connectors from TE Connectivity (TE) deliver rugged reliability in challenging and harsh environments

More information

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS Designed and independently tested to meet all requirements of IEC 61914. Integral stainless steel clamping plates to ensure

More information

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10 Cradle Relay Accessories and Mounting 108-98016 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet,

More information

QUADRAX D-SUB CONNECTORS

QUADRAX D-SUB CONNECTORS QUADRAX D-SUB CONNECTORS RUGGED QUADRAX DESIGN ENABLES GIGABIT ETHERNET SPEEDS WITH SUPERIOR SHIELDING PERFORMANCE FOR SIGNAL INTEGRITY QUADRAX D-SUB CONNECTORS Quadrax High-Speed Connectors WELL ESTABLISHED

More information

Gas Discharge Tubes. Features: Benefits: Applications:

Gas Discharge Tubes. Features: Benefits: Applications: TE Circuit Protection 5mm 3Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines from

More information

Universal Connectivity Platform

Universal Connectivity Platform Enabling Business Transformation through Agility Availability Efficiency UCP provides a fully modular approach to accommodate both copper and fiber into one common footprint, simplifying network architecture

More information

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE Robert Moore, Principal Engineer High Speed Specialist AEROSPACE, DEFENSE & MARINE /// WHITE PAPER - COMMERCIAL PROTOCOLS AND AEROSPACE

More information

KILOVAC K1K High-Voltage Contactor

KILOVAC K1K High-Voltage Contactor KILOVAC K1K High-Voltage Contactor High Performance in a Compact, Lightweight, Hermetically Sealed Contactor Designed for up to 1000 V/1000 A in Harsh Environments KILOVAC K1K High-Voltage Contactor Compact,

More information

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS ENERGY /// LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY (LVHS JOINTS) LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS TE Connectivity (TE) offers a wide range of reliable

More information

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE Authors: Stefan Glaser Senior Manager Customer Engineering VWA Waldemar Stabroth Director Technical Marketing Contact:

More information

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS ENERGY /// RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS ADVANCED SWITCHGEAR CONNECT TECHNOLOGY

More information

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES KEY FEATURES Hermetically sealed intrinsically safe. Operates in explosive/harsh environments without oxidation or contamination of contacts, including long periods of non-operation 8kV isolation between

More information

Jan05 Rev A EC

Jan05 Rev A EC Product Specification Two Circuit Heavy Duty Burner Connector 108-1056 12Jan05 Rev A EC 0990-0059-05 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the

More information

Gas Discharge Tubes GTCX28-XXXM-R05 Series

Gas Discharge Tubes GTCX28-XXXM-R05 Series GTCX28-XXXM-R05 Series Raychem Circuit Protection Products 8mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal

More information

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv Energy Division Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv Our Raychem heat-shrinkable medium voltage terminations

More information

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) TYPE-TESTED, FIELD-PROVEN INNER CONE CONNECTORS Inner cone

More information

DEUTSCH D3 SERIES PCB CONTACTS FOR SERIES III-STYLE CONNECTORS

DEUTSCH D3 SERIES PCB CONTACTS FOR SERIES III-STYLE CONNECTORS EUTSCH 3 SERIES PCB CONTCTS FOR 38999 SERIES III-STYE CONNECTORS QUICK REFERENCE GUIE Wide Range Mil spec, commercial, and composite shells Variety of standard and custom tail lengths available Choice

More information

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications DEUTSCH 369 Series PCB-Mount Connectors DEUTSCH 369 Series connectors

More information

RAYCHEM MEDIUM VOLTAGE

RAYCHEM MEDIUM VOLTAGE ENERGY /// RAYCHEM MV OUTDOOR SURGE ARRESTERS RAYCHEM MEDIUM VOTAGE Surge Arresters for special applications Raychem MV Indoor Surge Arresters Raychem MV Surge Arresters MPA for Indoor Applications For

More information

Universal Connectivity Platform A Modular Approach to Infrastructure Design

Universal Connectivity Platform A Modular Approach to Infrastructure Design A Modular Approach to Infrastructure Design TE Connectivity s Universal Connectivity Platform (UCP) provides a fully modular approach to designing data centers and telecommunications rooms. This patch

More information

Incutrol/2 Regulator

Incutrol/2 Regulator 12216-08 Model 2597A Incutrol/2 Regulator Hach Company, 1986-1996. All rights. reserved. Printed in the U.S.A. 05/95 13ed 09/96 rev2 2 Table of Contents Specifications...1 General Description...2 Setup...2

More information

Contacts for Econoseal III Connectors Series.070 (1.8 mm) and Series.250 (6.3 mm)

Contacts for Econoseal III Connectors Series.070 (1.8 mm) and Series.250 (6.3 mm) Series.070 (1.8 mm) and Series.250 (6.3 mm) Introduction Tyco Electronics Econoseal III sealed connector range has been designed to meet the exacting requirements of the automotive industry, for a reliable

More information

CII FCAC-150 Series Relay

CII FCAC-150 Series Relay Introducing CII Series Relay 50 Amps, 1PST/NO (DM) CII Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts KEY FEATURES Non-latching relay Balanced force design Corrosion protected metal enclosure

More information

Your Pick... One Solution

Your Pick... One Solution Abrasion Resistance NBCCS EMC Safety High Speed Complete Harnessing Solutions Repairability Reliability Extreme Temperatures Flexibility Your Pick... One Solution Low Outgassing Flame Retardant Fuel and

More information

WILDLIFE AND ASSET PROTECTION PRODUCTS

WILDLIFE AND ASSET PROTECTION PRODUCTS WILDLIFE AND ASSET PROTECTION PRODUCTS Protection and Prevention Before You Need It ADVANCED PROTECTION FOR MORE RELIABLE POWER DISTRIBUTION As structural building developments and roadways increase, more

More information

Cat 6 Shielded Patch cords

Cat 6 Shielded Patch cords Product Specification 108-93010 14/Oct/2009 Rev E Cat 6 Shielded Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT*

More information

HARTMAN Smart AC Contactors

HARTMAN Smart AC Contactors HARTMAN Smart AC Contactors Intelligent Contactors for Critical Aerospace Applications Intelligent Power Protection Products One of the most important trends today for military and aerospace contactors

More information

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214

More information

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS TE Energy offers a wide range of reliable and cost-effective products for the electrical power industry. Our position as

More information

RENEWABLE ENERGY. Durable solutions for maximum efficiency and the promise of reliability. ENERGY PIONEERS IN POWER SOLUTIONS

RENEWABLE ENERGY. Durable solutions for maximum efficiency and the promise of reliability. ENERGY PIONEERS IN POWER SOLUTIONS REEWABE EERY urable solutions for maximum efficiency and the promise of reliability. EERY PIEERS I PWER SUTIS BRII REEWABE EERY T THE WR TE Connectivity (TE) offers a comprehensive range of solutions that

More information

Tether and Umbilical Cables for Remotely Operated Vehicles

Tether and Umbilical Cables for Remotely Operated Vehicles Tether and Umbilical Cables for Remotely Operated Vehicles 6000 meters down is no place for cable failure TE Connectivity (TE) helps you go deep, whether it s to the ocean floor, the bottom of a mine,

More information

S200 SHIELD TERMINATORS

S200 SHIELD TERMINATORS RAYCHEM S200 SHIELD TERMINATORS FAST, EASY SHIELD TERMINATION AND GROUNDING TO 200 C RAYCHEM S200 SHIELD TERMINATORS High-Performance, High-Temperature Cable Terminators Heat-Shrinkable Sleeve for Fast,

More information

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY White Paper 23 May 2013 Rev A 503-32020 GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY Background Safety is paramount in the home appliance industry. Due to the possibility of human misapplication, over-current,

More information

Cat 6 Unshielded Patch cords

Cat 6 Unshielded Patch cords Product Specification 108-93017 13/Oct/2009 Rev D Cat 6 Unshielded s 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Cat

More information

/Oct/2014 Rev B

/Oct/2014 Rev B Product Specification 108-93042 07/Oct/2014 Rev B Class EA shielded solid Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE

More information

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT) TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions

More information

M7100 Pressure Transducer

M7100 Pressure Transducer SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces

More information

CabLite VR LED Lighting System Installation Manual

CabLite VR LED Lighting System Installation Manual CabLite VR LED Lighting System Installation Manual REV: 2.1 DATE: 1/5/2018 MANUAL NUMBER: 36 ELECTRONIC CONTROLS, INC. 7073 NORTH ATLANTIC AVE CAPE CANAVERAL, FL 32920 WWW.ECIAMERICA.COM REV DATE DESCRIPTION

More information

NECTOR S Line lighting components. Flexible solutions for your lighting designs

NECTOR S Line lighting components. Flexible solutions for your lighting designs NECTOR S Line lighting components Flexible solutions for your lighting designs The lighting industry is always changing. It is constantly in pursuit of more energy-efficient products with longer life-spans

More information

Figure 1. Figure 2. See notes 1 and 2 below.

Figure 1. Figure 2. See notes 1 and 2 below. 273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc. com INSTALLATION INSTRUCTIONS HORN SPEAKER WITH AMPLIFIER Use this product according to this

More information

/Oct/2014 Rev E

/Oct/2014 Rev E Product Specification 108-93017 14/Oct/2014 Rev E Cat 6 Unshielded Patch Cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE Connectivity

More information

CabLite ECO Installation Manual

CabLite ECO Installation Manual CabLite ECO Installation Manual REV : 4.1 DATE: 1/17/2018 MANUAL NUMBER : 32 ELECTRONIC CONTROLS, INC. 7073 NORTH ATLANTIC AVE CAPE CANAVERAL, FL 32920 WWW.ECIAMERICA.COM REV DATE DESCRIPTION 1.0 10/28/2013

More information

Built-In Electric Wall Oven

Built-In Electric Wall Oven uilt-in lectric Wall Oven Installation uide NW9000K Install_NW9000K_68-00000_00_N.indd 1 2016-06-30 6:21:36 ontents Safety informations Safety informations 2 Related equipment safety ontents Related equipment

More information

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES TE CONNECTIVITY S CYLINDER HEAD FOR INDUSTRIAL & COMMERCIAL VEHICLES WE GO TO EXTREMES TO MAKE EVERY CONNECTION COUNT INDUSTRIAL & COMMERCIAL TRANSPORTATION /// CYLINDER HEAD FOR INDUSTRIAL & COMMERCIAL

More information

Jun08 Rev C

Jun08 Rev C Product Specification Connector, Card Edge,.050 Centerline 108-14034 02Jun08 Rev C 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for Tyco Electronics.050 centerline

More information

Two Circuit Heavy Duty Burner Connector

Two Circuit Heavy Duty Burner Connector Product 108-1056 11 Oct.16 Rev B Specification EC 0990-0059-05 Two Circuit Heavy Duty Burner Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the

More information

AUTOMOTIVE MINIATURE WIRE (AMW)

AUTOMOTIVE MINIATURE WIRE (AMW) 0.13 mm 2 and 0.17 mm 2 AUTOMOTIVE MINIATURE WIRE (AMW) T4 (150 C/3000 hrs) TE AUTOMOTIVE /// AUTOMOTIVE MINIATURE WIRE (AMW) 0.13 mm 2 and 0.17 mm 2 AUTOMOTIVE MINIATURE WIRE (AMW) T4 (150 C/3000 hrs)

More information

Wire and Cable The Industry Standard for Rugged, Reliable Performance

Wire and Cable The Industry Standard for Rugged, Reliable Performance Wire and Cable The Industry Standard for Rugged, Reliable Performance TE Connectivity A Powerful Source Pushing the Performance Envelope As one of the world s largest suppliers of passive electronic components

More information

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

Insulation and Protection Enhancing the Reliability of Overhead Power Systems Insulation and Protection Enhancing the Reliability of Overhead Power Systems TE Energy TE Energy provides solutions for substations, underground cable, overhead lines, and railway applications. These

More information

Mar11 Rev B

Mar11 Rev B Product Specification 108-1576-2 11Mar11 Rev B NETCONNECT*, CHAMP* System 5 Modular Jack Patch Panel 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for NETCONNECT*

More information

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE Karl Kitts, Director of Development Engineering for High Performance Relays AEROSPACE, DEFENSE & MARINE /// WHITE PAPER - CONTACTORS FOR AEROSPACE

More information

PolySwitch Surface-Mount Resettable Fuses

PolySwitch Surface-Mount Resettable Fuses PolySwitch Surface-Mount Resettable Fuses New surface-mount products reduce the footprint and extend the operating range of the broadest product line of surface-mount resettable fuses Raychem, inventor

More information

626 Pneumatic Tool System The Effortless Alternative to Hand Crimping

626 Pneumatic Tool System The Effortless Alternative to Hand Crimping The Effortless Alternative to Hand Crimping Fast Facts Effortless crimping for a broad range of terminals, either bench-mounted or hand-held for working in cramped quarters. Lightweight tool eliminates

More information

Cannon ZIF Connectors

Cannon ZIF Connectors L - Plastic ody The annon L Series of Zero Insertion Force (ZIF) connectors fill the need in the medical, commercial / industrial, computer, and peripheral equipment market places for low-cost, high performance,

More information

Jun08 Rev A

Jun08 Rev A Product Specification Terminal Block Crimp Snap Plug Assembly 108-2319 09Jun08 Rev A 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics

More information

SONANCE PROFESSIONAL SERIES

SONANCE PROFESSIONAL SERIES PROFESSIONAL SERIES SURFACE MOUNT SPEAKER PS-S3T Introducing the Sonance Professional Series From Sonance, the company that created the architectural audio category comes a range of professional loudspeakers

More information

TE Connectivity's AMP NETCONNECT Cable Management

TE Connectivity's AMP NETCONNECT Cable Management One of the major challenges facing cabling mounting holes installers and maintenance personnel is organizing distribution cables and patch cords in the telecommunications room. TE Connectivity's AMP NETCONNECT

More information

PROFESSIONAL SERIES PENDANT SPEAKER PS-P63T

PROFESSIONAL SERIES PENDANT SPEAKER PS-P63T PROFESSIONAL SERIES PENDANT SPEAKER PS-P63T Introducing the Sonance Professional Series From Sonance, the company that created the architectural audio category comes a range of professional loudspeakers

More information

SONANCE PROFESSIONAL SERIES

SONANCE PROFESSIONAL SERIES PROFESSIONAL SERIES SURFACE MOUNT SPEAKER PS-S63T Introducing the Sonance Professional Series From Sonance, the company that created the architectural audio category comes a range of professional loudspeakers

More information

Inverted Through Board Surface

Inverted Through Board Surface Inverted Through Board Surface Application Specification Mount Technology (SMT) 114-13245 Connector Assembly 14 DEC 09 Rev E NOTE i All numerical values are in metric units [with U.S. customary units in

More information

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL 95 Methodist Hill Drive Rochester, NY 14623 Phone: US +1.585.321.5800 Fax: US +1.585.321.5219 www.spectracomcorp.com Part Number 8143-5000-0050

More information

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT INSTALLATION GUIDE Document No. 3000-A2-GB41-50 October 2002 COMSPHERE 48 Vdc Central Office Power Unit COMSPHERE 48 Vdc Central Office Power Unit Installation

More information

BUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals

BUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals BUDI-M-SP I N S T A L L A T I O N I N S T R U C T I O N Building distributor Introduction Suitable for FTTH applications where easily pre-connectorized splittersmodules can be build in. The box is designed

More information

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY White Paper BACKGROUND: Safety is paramount in the home appliance industry. Due to the possibility of human mis-application, over-current, or short circuit

More information

Apr06 Rev A

Apr06 Rev A Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece

More information

NT DUAL CHANNEL DISPLAY. User Guide

NT DUAL CHANNEL DISPLAY. User Guide NT DUAL CHANNEL DISPLAY User Guide Table of Contents Introduction... 2 Input Signals... 2 Output Signals... 2 User Programmable Features... 2 Installation... 3 Mechanical Installation... 3 Dimensional

More information

Brute Elite Volume Water Heaters Indoor 150, ,000 BTU/Hr. Up to 97% Thermal Efficiency

Brute Elite Volume Water Heaters Indoor 150, ,000 BTU/Hr. Up to 97% Thermal Efficiency rute lite Volume ater eaters Indoor 1,000 -,000 TU/r. Up to % Thermal fficiency The unit will be designed and constructed in accordance with the S oiler and Pressure Vessel ode Section IV requirements

More information

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC. 108-37065 Product Specification Rev. A 18-Jan-2007 Housing Assy 5p Hybrid Std./Jr. Power Timer Tab & Rec. DESIGN OBJECTIVES The product described in this document has not been fully tested to insure conformance

More information

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter Installation Instructions for the LM Series MCU (Microcontroller Unit) Issue 3 50082092, CAUTION Be cautious when working around and connecting to the LM Series terminals, especially those other than the

More information

Universal Retention Modules 02 MAR 10 Rev A

Universal Retention Modules 02 MAR 10 Rev A NOTE i Application Specification 114-26017 Universal Retention Modules 02 MAR 10 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and

More information

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation Sold by: http://www.twacomm.com Toll Free: (877) 389-0000 Commercial / Industrial Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation Introduction lev-lok

More information