1 OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION JPR Task(s): Remove Auto Glass (Laminated or Tempered) Skill No PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate, with assistant and wearing appropriate protective clothing and eye protection, shall demonstrate the proper removal of a windshield, side or rear glass from a motor vehicle as indicated." Minimum PPE: Full PPE w/o SBA PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. onfirm order with the officer for the rescue operation 2. Assess area for fire/explosion hazards, verbalizes precautions to be taken. (Suppression equipment, etc.) 3. andidate removes glass properly using acceptable techniques. 4. Glass removal avoids causing further hazards or injuries. "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 3 Evaluator 1 Objective(s): 6.4.1
2 JPR Task(s): Remove Vehicle Roof OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION Skill No PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate, with assistance and wearing appropriate protective clothing and eye protection, shall demonstrate the proper removal of a motor vehicle roof." Minimum PPE: Full PPE w/o SBA PERFORMANE andidate must successfully pass this skill in 20 minutes to pass 1. onfirm order with officer to remove roof 2. Plan the operation (method of roof removal) before starting work. 3. heck the area in which the work is to be done. 4. Verbalizes need to assess for flammable vapors and to produce no sparks 5. Verbalizes need to assess vehicle restraint systems and adverse effects on operation. 6. uts all roof post at the proper location based on model of vehicle, safety systems, and vehicle construction. 7. Positions four firefighters, one near each A post and one near each post. 8. Lift the roof off of the vehicle using legs and not back being sure to avoid twisting motions 9. Move the roof to an area in which it will not endanger others or interfere with operations. "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 7 Evaluator 1 Objective(s): 6.4.1
3 OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION JPR Task(s): Steering Wheel or olumn Removal Skill No PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate, with assistant and wearing appropriate protective clothing and eye protection, shall demonstrate the proper techniques of collapsing or removing the steering wheel and/or column of a vehicle. Minimum PPE: Full PPE w/o SBA PERFORMANE andidate must successfully pass this skill in 20 minutes to pass 1. onfirm order with officer to prepare vehicle 2. Plan the operation before starting work. 3. Determine impact of supplemental systems and isolate as necessary (i.e. De-Energize of Disconnect battery or batteries) 4. Remove windshield or roof if necessary to gain access. 5. Assesses the area for flammable vapors and acts accordingly with equipment choice 6. ut component to be removed using hydraulic shears, reciprocating saw, or bolt cutters 7. Remove the component using care not to injure passengers and using proper lifting. 8. Move the component to an area in which it will not endanger others or interfere with operations. "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 6 Evaluator 1 Objective(s): 6.4.1
4 OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION JPR Task(s): Displace Vehicle Dashboard Skill No PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate, with assistance and wearing appropriate protective clothing and eye protection, shall demonstrate the proper method of performing a dashboard displacement (rollup) of a motor vehicle." Minimum PPE: Full PPE w/o SBA PERFORMANE andidate must successfully pass this skill in 20 minutes to pass 1. onfirm order with officer to displace the dashboard 2. Plan the operation before starting work by determining the method of removing vehicle front doors. 3. Remove windshield 4. Directs team to remove front doors. 5. Makes relief cuts in A post and rocker panel at base of post on each side of vehicle. 6. Makes relief behind the strut mounts to eliminate vehicle movement 7. Positions the extension rams or other tools to move dashboard. 8. Operates tools until dashboard is moved clear of passengers. 9. Places cribbing or block in relief cut to hold dashboard in displaced position on each side. 10. Remove the tools by relieving pressure. "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 7 Evaluator 1 Objective(s): 6.4.1
5 OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION JPR Task(s): Pre-Incident Survey and Related Documentation Skill No PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate shall demonstrate, using the supplies and scenario provided, the proper method of performing a FD pre-fire survey of a facility." Minimum PPE: Helmet PERFORMANE andidate must successfully pass this skill in 20 minutes to pass 1. Verbalizes that inspector should use main entrance and needs neat appearance. 2. Introduces self and explains purpose of visit. 3. Obtains permission to perform a survey of the facility. 4. Surveys exterior of facility checking for hydrants, connections, accessibility, general 5. Draw exterior field sketch. 6. Verbalizes the need to perform flow tests on water supply in area. 7. Photographs structure from several angles, if acceptable. 8. Survey building interior, starting from roof down or lowest floor up. 9. Notes protection systems and life safety information. 10. Draw rough sketch of interior, floor by floor. 11. Notes locations of hazards on the sketch. 12. Looks for and verbalizes need to survey other structures on same property. 13. Performs an exit interview. 14. omplements owner/manager on good conditions found. 15. Gives tips to improve poor conditions for safety. 16. Thanks occupant for permission and answers any questions. "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 12 Evaluator 1 Objective(s): 6.5.3,6.5.1
6 OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION JPR Task(s): Inspect Protected Property with Fire Suppression Systems Skill No PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate shall demonstrate a FD inspection of property with fire detection, alarms and fixed extinguishing systems." Minimum PPE: Helmet PERFORMANE andidate must successfully pass this skill in 20 minutes to pass Fire detection and alarm systems 1. Inspects all fire detection and alarm systems present. 2. Looks for and records any missing components. 3. Inspects enunciator panel, should be on and showing normal. Fixed Extinguishing Systems 4. Inspects the water supply valves. 5. Inspects the pressure gauges. 6. Inspects systems components. 7. Inspects the sprinkler heads. 8. Inspect special agent extinguishing systems. 9. Records all data. "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 7 Evaluator 1 Objective(s): 6.5.1
7 OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION JPR Task(s): Service and Maintain Generator and Lighting Equipment Skill No PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate using appropriate hand and eye protection, given a partner, portable lighting equipment and a generator, shall demonstrate refueling, adding oil, inspecting generator unit, inspecting lighting equipment and changing bulbs in lights." Minimum PPE: Gloves, Helmet and Eye Protection PERFORMANE andidate must successfully pass this skill in 15 minutes to pass 1. With assistance, removes generator from storage, using proper lift techniques. 2. Inspects spark plug, changes as necessary, gaps to specifications. 3. Inspects plug wire for damage or frayed wire. 4. Inspects carburetor. 5. Adequate fuel level. Ensures fresh fuel. 6. hecks oil level. Adds as necessary. 7. Inspects all lighting equipment. 8. Starts generator, checks light operation (assume bulb is bad). 9. Disconnects power prior to servicing. 10. Removes defective bulb and installs proper replacement, if necessary. 11. Discards faulty bulb and return equipment to proper storage. 12.Documents inspection data and reports equipment needing service or removed from service to command. "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 9 Evaluator 1 Objective(s): 6.5.4
8 JPR Task(s): Service Test Fire Hose OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION Skill No PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate, in appropriate protective clothing and given the necessary equipment and pumper, shall demonstrate the proper testing/tagging of hose and the recording of test test results." Minimum PPE: Helmet and Gloves PERFORMANE andidate must successfully pass this skill in 20 minutes to pass 1. Lays out hose in straight run. 2. Inspects all gaskets before connecting and replaces as needed. 3. Test lengths must be shorter that 300 feet. 4. ompletes all connections. Attaches nozzle. 5. Secures each section of hose with hose straps. 6. Flushes hose of all trapped air, straightens any kinks/twists. 7. Marks each hose jacket at the coupling edge. 8. Sets pump pressure to that specified by current NFPA 1962 for hose testing. 9. Monitors lines for leakage. Maintains appropriate pump pressure for 5 minutes. 10. Ends test, bleeds off lines. 11. Inspects couplings for slippage. Marks test date on hose. 12. Records data, tags sections out of service with unacceptable slippages. "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 9 Evaluator 1 Objective(s): 6.5.5
9 OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION JPR Task(s): Fire Safety Survey of a Private Dwelling Skill No PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate shall demonstrate conducting a courtesy residential fire safety survey of a private single-family occupancy. " Minimum PPE: Helmet PERFORMANE andidate must successfully pass this skill in 20 minutes to pass 1. andidate verbalizes he or she shall be dressed appropriately. 2. Uses sidewalk, does not walk on lawn 3. Introduces self, states purpose of visit, asks permission to conduct courtesy survey. 4. Verbalizes that if no one home, leaves safety literature between doors 5. Upon invitation, cleans shoes before entering, removes cap if applicable 6. Surveys rooms, one at a time with the occupant noting conditions found that pose a fire or safety risk along the way, offering suggestions for correction 7. Inspects the exterior of the home noting and explaining conditions found that may contribute risk of fire and offering suggestions for correction. 8. Provides home fire safety information concerning escape plans, smoke detector placement and upkeep, and emergency phone numbers (minimum) 9. oncludes the survey by complimenting occupant on safe conditions found and thanks occupant for invitation to conduct survey. "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 7 Evaluator 1 Objective(s): 6.5.1
10 OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION JPR Task(s): onduct a Fire Station Tour Skill No PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate shall demonstrate planning and conducting a fire station tour. Group consist of 10 ub Scouts and 2 adult leaders." Minimum PPE: Helmet PERFORMANE andidate must successfully pass this skill in 20 minutes to pass 1. Secures station for tour. Notifies all appropriate personnel. 2. Has a teaching outline appropriate for the visiting age group. 3. Greets tour members and introduces helpers 4. Explains what will take place and what the role of adults in the group will be during the tour, (i.e. If an alarm comes in, what to do and where to go) 5. Uses appropriate terminology for the age of the group, stays simple and short 6. Provides an overview of the department and the fire service in general 7. Provides age appropriate handouts, stickers, etc. 8. oncludes the tour by escorting the group away from the station and thanking them for coming. Thanks all adults with handshake and an invitation to return. 9. ompletes the Station Tour Report and forwards to appropriate officer "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 7 Evaluator 1 Objective(s): 6.5.2
FIREFIGHTER 1 COMPETENCY EVALUATION
OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY JPR Task(s): Operate Portable Fire Extinguishers FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-46 PERFORMANE
More informationFIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES
10 FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES GENERAL 1- Demonstrate procedures for assuming and transferring command at an emergency scene, utilizing an incident management system. REFERENCE: NFPA 1001,
More informationBased on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.
Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition. Revised 02/10/2017 Alabama Fire College Firefighter II Instructional JPR Verification Sheet Full Name: Fire Department:
More informationFIREFIGHTER 1 COMPETENCY EVALUATION
JPR Task(s): Operate Portable Fire Extinguishers Skill No. 1-46 "The Candidate, provided a scenario of each fire class (A, B and C) in an incipient stage, shall demonstrate the operation of extinguishers
More informationBased on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition
Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Alabama Fire College Airport Firefighter Instructional JPR Verification Sheet Full Name: Fire Department: This Instructional
More informationS Fire Fighter II. Supplementary Material: Performance Test. Air Force Institute for Advanced Distributed Learning
CDC 10012 10012 01 S01 0404 Fire Fighter II Supplementary Material: Performance Test Air Force Institute for Advanced Distributed Learning Air University Air Education and Training Command i Acknowledgement
More informationAdditional Materials: Instructor s PowerPoint, Question Files
Course Delivery Formats: Online Interactive Course Online Streamed Video DVD Additional Materials: Instructor s PowerPoint, Question Files When it comes to mastering the basics for certification or refresher
More informationChapter 3 FF II Fire Department Communications
Chapter 3 FF II Fire Department Communications After completing this lesson, the student shall be able to discuss on-scene communications and postincident reports. 1. Describe the aspects that make up
More informationEASTERN ARIZONA COLLEGE Fire Department Operations II
EASTERN ARIZONA COLLEGE Fire Department Operations II Course Design 2015-2016 Course Information Division Allied Health Course Number FSC 102 Title Fire Department Operations II Credits 5 Developed by
More informationFIRE FIGHTER II NFPA 1001, Chapter 6, 2013 Edition
Official Skill Sheets for Practical Skills Ontario, Canada FIRE FIGHTER II NFPA 1001, Chapter 6, 2013 Edition National Fire Protection Association Standard for Fire Fighter Professional Qualifications
More informationFRS 201. Firefighters Advanced Skills I. 45 clock hours 3 credit bouts
FRS 201 Firefighters Advanced Skills I 45 clock hours 3 credit bouts Course Title Lecture/Skill Total Fractional FRS 2011 Firefighter Safety II 4 0 4 0.3 FRS 2012 Ladders II 10 1 11 0.7 FRS 2013 Rescue
More informationADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL
ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL 1- Utilize a pre-incident plan so that the industrial fire brigade member implements the responses detailed by the plan. NFPA
More informationINTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL
INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL 1- Utilize a pre-incident plan so that the industrial fire brigade member implements the responses detailed by the plan. NFPA 1081, 2012
More informationFIRE PROTECTION BUREAU ACCREDITATION AND CERTIFICATION PO Box Olympia WA (360) FAX: (360) AIRPORT FIREFIGHTER
5.2 RESPONSE 5.2.1 Responding to Incidents Daytime Evaluation Sheets: 5.2.1; 5.3.6 Skill Sheet: A Birth STANDARD: 5.2.1 and 5.3.6 TASK: Respond to a daytime incident or accident on and adjacent to the
More informationFIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure
NFPA 1001: 6.2.2 FIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure OBJECTIVE Trainee shall define and demonstrate prescribed
More informationAIRPORT FIRE FIGHTER ID#: STANDARD:
4.1 General Requirements Evaluation Sheet: ARFF 4.1.1.4-A 4.1.1.4 General Skill Requirements JPR - HAF - 1 Standard Area: General Skill Requirement Revised 1/27/2017 STANDARD: 4.1.1.4 FAA #3 Rescue Safety
More informationEssentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)
Essentials of Fire Fighting, Fourth Edition Transition Guide Chapter 1: The History of the Fire Service (Essentials, Chapter 1) This chapter covers the history of the fire service, the organization of
More informationWilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087
SOG Name: Multi Family Dwelling SOG Number: 403.15 Effective Date: February 2, 2015 Approved: Joey Cooper, Director Reviewed: Scope This procedure has been developed to provide WEMA with a set of guidelines
More informationINCIPIENT FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL
INCIPIENT FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL 1- Initiate a response to a reported emergency and transmit and receive messages via the facility communications system so that all necessary
More informationSaskatchewan Evaluation and Certification Guide. Appendix D
Saskatchewan Evaluation and Certification Guide Appendix D NFPA 1002 Fire Apparatus Driver/Operator Professional Qualifications Revised 2013 Emergency Management and Fire Safety Page 1 of 13 Table of Contents
More informationGREEN SHEET. Los Angeles Fire Department. Informational Summary Report of Serious LAFD Injuries, Illnesses, Accidents and Near-Miss Incidents
GREEN SHEET Los Angeles Fire Department Informational Summary Report of Serious LAFD Injuries, Illnesses, Accidents and Near-Miss Incidents FIREFIGHTER INJURY SOLANO AVENUE VEHICLE FIRE This report is
More informationCORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS
CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS FIRE EXTINGUISHER REQUIREMENTS 1. All commercial cooking operations require at least one 2A10BC rated (5 or 6 pound size) fire extinguisher.
More informationCumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07
Standard Operating Guidelines Page: 1 of 6 15.07 Scope: Commercial properties shall include businesses, schools and shops with very limited special hazards. 15.0701 First engine placement: Positioning
More informationDriver Operator Pumps: Sprinkler and Standpipe Operations
Driver Operator Pumps: Sprinkler and Standpipe Operations 2 Skills Total NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition 1 Driver Operator Pumps: Sprinklers and Standpipe
More informationPro Board Assessment Methodology Matrices for NFPA 1001
Pro Board Assessment Methodology Matrices for NFPA 1001 NFPA 1001 - Fire Fighter I - 2013 Edition INSTRUCTIONS: In the column titled Cognitive/Written Test place the number of questions from the Test Bank
More informationStandardized Curriculum Form Ontario, Canada
Standardized Curriculum Form Ontario, Canada Office of the Fire Marshal and Emergency Management Curriculum based on NFPA 1001, Chapter 5, 2013 Edition FIRE FIGHTER I National Fire Protection Association
More informationMASTER COURSE OUTLINE
A. FIRE 1100 Firefighter I B. COURSE DESCRIPTION: MASTER COURSE OUTLINE This course is designed to cover the necessary skills to perform the basic duties of firefighting including thought processes used
More informationEASTERN ARIZONA COLLEGE Fire Department Operations I
EASTERN ARIZONA COLLEGE Fire Department Operations I Course Design 2015-2016 Course Information Division Allied Health Course Number FSC 101 Title Fire Department Operations I Credits 6 Developed by B.K.
More informationFamily Foster Home Fire Safety Evaluation Checklist Instructions
Family Foster Home Fire Safety Evaluation Checklist Instructions Please read these instructions prior to commencing your inspection. This checklist is provided to specific Foster Family Homes for the purpose
More informationNFPA Fire Fighter I (Including Entry Level Fire Fighter) Task Book
State of Oregon Department of Public Safety Standards and Training NFPA Fire Fighter I (Including Entry Level Fire Fighter) Task Book Task Book Assigned To: Name DPSST Fire Service # Department Name Date
More informationFIRE FIGHTER II APPLICATION PENNSYLVANIA VOLUNTARY FIRE SERVICE CERTIFICATION PROGRAM NFPA Edition
FIRE FIGHTER II APPLICATION PENNSYLVANIA VOLUNTARY FIRE SERVICE CERTIFICATION PROGRAM NFPA 1001 2008 Edition SECTION I Last Name First Name M.I. SSN (last four digits required) Street Address City State
More informationRequired Materials For complete material(s) information, refer to
Butler Community College Health, Education, and Public Safety Division Troy R. Jellison Revised Fall 2018 Implemented Spring 2019 COURSE OUTLINE Firefighter 1 Course Description FS 100. Firefighter 1.
More informationFRS 101 INTRODUCTION TO FIRE SERVICE 45 CLOCK HOURS 3 CREDIT HOURS. Course Title Lecture/Skill Total Fractional Credit
FRS 101 INTRODUCTION TO FIRE SERVICE 45 CLOCK HOURS 3 CREDIT HOURS Course Title Lecture/Skill Total Fractional FRS 1011 Fire Department Organization 10 0 10 0.7 FRS 1012 Fire Behavior 4 0 4 0.3 FRS 1013
More informationPrereq: FOD 131 or Instructor Permission
FOD 101--Required Fire Officer I: This course is an introduction to a fire officer s duties. The content includes report writing, diversity issues, work-place safety, decision-making, quality assurance,
More informationTEN STEP PROCESS PREPARING FIRE SAFETY PLANS
TEN STEP PROCESS PREPARING FIRE SAFETY PLANS STEP 1 CONDUCT FIRE SAFETY AUDIT IDENTIFY BUILDING FEATURES AND HUMAN RESOURCES. STEP 2 APPOINTMENT OF SUPERVISORY STAFF IDENTIFY TRAINED SUPERVISORY STAFF
More informationOwner/Operator Guide for Successful Sprinkler and Fire Pump Systems
Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems Adam Olomon, P.E. Associate Consultant Fire & Life Safety and Fire Protection Introduction Adam Olomon Licensed Professional Engineer
More informationSeptember 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal
M.S. Montgomery Fire Marshal September 1, 2010 This document describes rules changes affecting the operation and fire safety in foster homes licensed and regulated by the Texas Department of Family and
More informationObjective 1: Describe the role of a Firefighter II in planning for and conducting private dwelling fire safety surveys.
Chapter 21 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe the role of a Firefighter II in planning for and conducting private dwelling fire
More informationTRAINING AND EDUCATION PAYMENT POLICY FOR TESTING
TRAINING AND EDUCATION PAYMENT POLICY FOR TESTING WRJFD POLICIES FOR TRAINING AND EDUCATION A. BASIC TRAINING REQUIREMENTS 1. The Fire District will provide training and education for all Fire Department
More informationAirport Firefighter Recertification Core Competency Task Book
2011 Airport Firefighter Recertification Core Competency Task Book Agency:_ TASK BOOK ASSIGNED TO: INDIVIDUAL S PRINTED NAME & TITLE 1 2 DO NOT COMPLETE THIS UNLESS YOU ARE RECOMMENDING THE INDIVIDUAL
More informationInspection and Testing of Water-Based Systems
Inspection and Testing of Water-Based Systems Standard Model/Computer-Based Testing Level II Content Outline The candidate for NICET certification at Level II in the Inspection and Testing of Water- Based
More informationElko County Human Resources Employment Opportunity Announcement
Position opens: August 18, 2017 Elko County Human Resources Employment Opportunity Announcement POSITION: Firefighter I/Firefighter II Elko Station SALARY: Firefighter I - Hourly Rates Firefighter II Hourly
More informationMachine Guarding. 1 Copyright 2014, Rev by PEC Safety Management, Inc. PPT-SM-MG 2014, Rev
Machine Guarding 1 Copyright by PEC Safety Management, Inc. The Importance of Machine Guarding Amputations are among the most severe and disabling workplace injuries Amputations may result from improperly
More informationFIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY
FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY PLAN REVIEWS SITE PLANS: 1) Access to buildings (Volume V NC Building Code sections 602.6.1
More informationMINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry
MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Fire Alarm Systems Plan Review Checklist Date: Permit Number: Business Name: Address: Fire Alarm System Submittal
More information1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone
Medicine Hat Fire Service Construction Site Fire Safety Plan ABC Part 9 Buildings 1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone 403-529-8282 Email fireprevention@medicinehat.ca Small Buildings
More informationNew Construction Fire Inspection Process
New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific
More informationJUNE NEWSLETTER- FALLIING OBJECTS
JUNE NEWSLETTER- FALLIING OBJECTS Struck by, or contact with a falling object is the third leading cause of firefighter deaths. According to the NFPA s annual death and injury survey only stress and being
More informationProposed construction of National Institute of Homeopathy at Sec-A8, Narela Delhi by Ministry of Ayush. Risk Assessment
Risk Assessment Building and construction project involve high risk category having many associated hazards like trip slip and fall, falling material, height at work, electrical hazard, & fire etc. Adequate
More informationLamorinda CERT - Unit 2 09/15/2016
Contra Costa County CERT Program Unit 2 Fire Safety Released: 15 September 2016 Community Emergency Response Team Personal safety is ALWAYS the number one priority Work as a team Wear personal protective
More informationFire Safety and Utility Controls. CERT Basic Training Unit 2
Fire Safety and Utility Controls Unit 2 Unit Objectives Explain role of CERTs in fire safety Identify and reduce potential fire and utility risks Describe CERT sizeup process Conduct basic sizeup for a
More informationChapter 17 Test. Directions: Write the correct letter on the blank before each question.
Chapter 17 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe initial factors to consider when suppressing structure fires. 1. Which strategy
More informationWinnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
More informationDEPARTMENTAL GUIDELINES CHAPTER 6 TACTICAL OPERATIONS
Section 400.000 Suppression Systems The purpose of this guide is to assist the Incident Commander (IC), Fire Officers and Firefighters with the planning of effective operations for supporting water-based
More information2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7
WET SPRINKLER Monthly Wet Sprinkler 2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 VISUALS [per NFPA 25-1998 ed] 1. Gauge (Ck for Condition, Normal Pressure) [per 2-2.4.1] 2. Valves
More informationFire/General Safety Review Program Key Performance Indicators Environmental Health and Safety
Fire/General Safety Review Program Key Performance Indicators Environmental Health and Safety Fire and CO Detection Systems Fire alarm pull station obstructed. Annunciation panel obstructed. Lack of approved
More informationBlack Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment
Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment February 2017 Alberta Fire Code safety equipment maintenance requirements: The Black Diamond Fire Department has
More informationPrevention. Education
Fire Prevention and Public Education Objectives (1 of 2) Identify elements of public fire safety education programs covering stop, drop, and roll; exit drills in the home; and installation and maintenance
More informationRapid Intervention Team
3.2.1.2 Rapid Intervention Team YOUR ORGANIZATION STANDARD OPERATING PROCEDURES/GUIDELINES TITLE: Rapid Intervention Team NUMBER: 3.2.1.2 PREPARED BY: SECTION/TOPIC: Fire Suppression Risk Management ISSUE
More informationCourse Outline Cover Page
College of Micronesia FSM P.O. Box 159 Kolonia, Pohnpei Course Outline Cover Page Advanced Fire Control and Prevention MM 173 Course Title Department and Number Course Description: To provide candidates
More informationCDC 10311W Fire Inspector I Performance Test
CDC 10311W Fire Inspector I Performance Test Extension Course Program (A4L) Air University Air Education and Training Command Acknowledgement Preparation of this supplement was aided through the cooperation
More informationNational Certification Program Study Guide
National Certification Program Study Guide October 2009 Driver/Operator Aerial NFPA 1002, Standard for Fire Appratus Driver/Operator Professional Qualifications, 2009 Edition This document is provided
More informationHot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope
1. Purpose The purpose of the University of Denver Hot Work policy is to protect personnel and property from a fire caused by hot work. The DU Hot Work policy defines the responsibilities and requirements
More informationHonolulu Community College Health & Safety Inspection Checklist for Shops Tech I. Program: Conducted by: Date: Reference 29 CFR 1910.
Program: Conducted by: Date: Means of Egress/Escape Are exits provided to permit the prompt escape of occupants in case of fire or other emergency? Is every exit, way of approach, and way to travel from
More information1.0 Basic Principles and Practices of Propane Performance-Based Skills Assessment 2016
1.0 Basic Principles and Practices of Propane Performance-Based Skills Assessment 2016 Section 1 Task 1 Task 2 Task 3 Task 4 Section 2 Task 1 Task 2 Task 3 Task 4 Section 3 Task 1 Task 2 Section 4 Task
More informationIAAI/USFA Abandoned Building Project
IAAI/USFA Abandoned Building Project FD Operations in Vacant/Abandoned Buildings Presentation Outline Introduction This lesson is intended to introduce fire department personnel to the conditions that
More informationUnit 2 Fire Safety (Zone 2)
IFE Level 3 Diploma in Fire Safety and Fire Science Unit 2 Fire Safety (Zone 2) Examiner Report March 2017 Introduction 21% of the candidates that sat the examination attained a pass. Candidates did not
More informationFire Prevention Plan
Fire Prevention Plan TABLE OF CONTENTS Section Title Page 1.0 Objective. 3 2.0 Background 3 3.0 Assignment of Responsibility.. 4 4.0 Plan Implementation..... 5 5.0 Types of Hazards...... 6 6.0 Training........
More informationIMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE
INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 0171-735 7611 Fax: 0171-587 3210 Telex: 23588 IMOLDN G Ref. T4/4.01 IMO E MSC/Circ.911 4 June 1999 INTERPRETATIONS OF FIRE
More information1.1.0 Protocols for the response to fires involving MRI Machines
MRI Responding to Fires Involving MRI Machines 1.1.0 Protocols for the response to fires involving MRI Machines 1.1.1 It is incumbent upon all Fire Department Personnel to remain knowledgeable about the
More informationPrerequisite/Co-requisite: Pass the reading and writing portions of COMPASS or other accepted testing instrument.
Industrial Fire Protection (FIRT 1347) Credit: 3 semester credit hours (3 hours lecture, 0 hours lab) Prerequisite/Co-requisite: Pass the reading and writing portions of COMPASS or other accepted testing
More informationFire Prevention Plan Program Prepared by: Allied Insurance Brokers, Inc.
Fire Prevention Plan Program Prepared by: Allied Insurance Brokers, Inc. Commonwealth Scaffold, LLC Effective Date: 12/14/2012 Revision Number: 1 TABLE OF CONTENTS 1. Fire Prevention Plan Program 1 2.
More informationFire Prevention Plan
Fire Prevention Plan TABLE OF CONTENTS Section Title Page 1.0 Objective. 3 2.0 Background 3 3.0 Assignment of Responsibility.. 4 4.0 Plan Implementation..... 5 5.0 Types of Hazards...... 6 6.0 Training........
More informationFIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION
CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION SECTION FC 1401 GENERAL 1401.1 Scope. This chapter shall govern fire safety measures during the construction, alteration, or demolition
More informationBROWNSVILLE VOLUNTEER FIRE DEPARTMENT
BROWNSVILLE VOLUNTEER FIRE DEPARTMENT USTANDARD OPERATING GUIDELINES U TABLE OF CONTENTS 100 - PROTECTIVE CLOTHING AND PERSONAL SAFETY 200 - DISPATCH 300 - DRIVER OPERATIONS 400 - APPARATUS RESPONSE/ASSIGNMENT
More informationICC CODE CORNER 2015 International Fire Code
PART II GENERAL SAFETY PROVISIONS CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS SECTION 401 GENERAL 401.1 Scope. Reporting of emergencies, coordination with emergency response forces, emergency plans and
More informationMinimum Information Required to Process your Special Occasion Application. Parking area Access to site
FIRE CODE PERMIT SPECIAL OCCASION APPLICATION YAKIMA COUNTY FIRE MARSHAL S OFFICE International Fire Code 128 N. 2nd Street, 4th floor, Yakima, WA 98901 - (509) 574-2300 FORM: BFS45A 6/5/18 Minimum Information
More informationGLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE
GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE To: From: Subject: Whom It May Concern Carl Ray Austerman, Fire Marshal Contractor s Guide Welcome to the Glendale Fire Department s Contractors Guide. This
More informationEmergency Planning and Preparedness
Emergency Planning and Preparedness Writing an Emergency Evacuation Plan A thorough emergency plan will include the following components: The procedure for reporting emergencies The procedure for relocating
More informationFIRE SAFETY. This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are:
FIRE SAFETY This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the program and the subject that it addresses.
More informationc. Explain how to safely discard and store flammable liquids.
FIRE SAFETY BYU PowWow Official Merit Badge Worksheet Scout s Name Instructor's Name Scout s Address City State ZIP Instructions 1) The Scout is to review the merit badge book before the first week of
More informationService Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT
58 Fire protection equipment requires care and maintenance at scheduled intervals to assure it will operate properly and safely when needed. Only personnel who are trained and qualified to maintain the
More informationModel Policy On Portable Fire Extinguishers (Ontario Version)
Model Policy On Portable Fire Extinguishers (Ontario Version) Every workplace needs a policy ensuring the appropriate selection, use, storage and maintenance of fire extinguishers. OHS managers in any
More informationRAMBLER PARK FIRE SAFETY INFORMATION
RAMBLER PARK FIRE SAFETY INFORMATION Parmenter Realty Partners 7557 Rambler Rd. Dallas, Texas 75231 214-373-9561 214-373-9620 (fax) RAMBLER PARK RAMBLER PARK FIRE SAFETY INFORMATION II. Objective To provide
More informationRequirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification
Requirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification In order to successfully pass the inspection, your property will need to meet all regulations mandated by the state and municipality.
More informationSOUTH LYON FIRE DEPARTMENT Manual of Procedures 111
PUBLIC EDUCATION - COMMUNITY EVENTS Issued: July 30, 2012 Revised: November 3, 2016 Approved: Chief Mike Kennedy I. PURPOSE The ability to prevent loss of life and property from fire through education
More informationEXCELSIOR FIRE DISTRICT
EXCELSIOR FIRE DISTRICT Minnesota State Fire Code and the Excelsior Fire District Inspection Fire Safety & Code Requirements TENTS OVER 200 SQUARE FEET The following codes set fourth by the Minnesota State
More informationFire Safety and Utility Controls. CERT Basic Training Unit 2
Fire Safety and Utility Controls Unit 2 Unit Objectives Explain role of CERTs in fire safety Identify and reduce potential fire and utility risks Describe CERT sizeup process Conduct basic sizeup for a
More information5.07 Air Replenishment Systems
5.07 Air Replenishment Systems Reference: 2010 SFFC, Section 511.2 Definitions: CERTIFIED COMPRESSOR. A compressor used by a contractor for maintenance and testing of air replenishment systems that is
More informationCamden County Fire Rescue Office of the Fire Marshal 125 N. Gross Road, Kingsland, GA
Camden County Fire Rescue Office of the Fire Marshal 125 N. Gross Road, Kingsland, GA 31548 912-510-4302 February 9, 2011 Greetings Camden County Businesses, As always, our department is working vigilantly
More informationWELDING, CUTTING, AND BRAZING SAFETY PROGRAM
WELDING, CUTTING, AND BRAZING SAFETY PROGRAM HOT WORK TABLE OF CONTENTS 1.0 Introduction 1.1 Purpose 1.2 Scope 2.0 Responsibilities 2.1 Building Office 2.2 Building Personnel 2.3 Individuals Performing
More informationTelecom Applications Management
Con EdIson SUBJECT: Manhole Inspections TeAM Policy Telecom Applications Management PAGE 1 of 4 POLICY NO.: 004-00-06-X Policy Statement Con Edison Electric Manholes : Telecommunications customers and
More informationGeneral Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin
The purpose of a monthly self-inspection program is to identify unsafe conditions in the work environment and unsafe employee actions. Management can then correct these safety hazards, reducing the potential
More informationSPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES
SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES Page 1 of 4 Volume: Training Section: 30.00 Number: 30.02 Subject: Live Fire Training Date Issued: 9 January 2017 Rescinds: Originator: Assistant Fire
More informationNATIONAL COMPETENCY STANDARD
NATIONAL COMPETENCY STANDARD WSQ Framework : WSH Professionals Competency Category : Implement operational control of WSH Competency Code : WP-IC-302C-1 Competency Unit : Coordinate implementation of emergency
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST FIRE AND LIFE SAFETY SYSTEMS FOR STRUCTURES FIVE OR MORE STORIES IN HEIGHT AND LESS THAN 75 FEET IN HEIGHT FROM THE POINT
More informationFIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures
FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures Building Name: Building Address: Plan Prepared By (please print): Date: Revision Date Comments Approval FIRE SAFETY MAINTENANCE
More informationTABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2
TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2 6.1] GENERAL... 2 6.2] EXCERPTS FROM 2012 BC FIRE CODE PART 2 BUILDING AND OCCUPANT FIRE SAFETY... 3 6.3] EXCERPTS FROM 2012 BC FIRE CODE
More informationSkill Sheet 17-I-1. Suppress an interior structure fire Direct, indirect, or combination attack. (NFPA 1001, , )
Skill Sheet 17-I-1 Objective 21: Suppress an interior structure fire Direct, indirect, or combination attack. (NFPA 1001, 5.3.10, 5.3.13) Student Name: Date: Directions For this skills evaluation checklist,
More informationRICHMOND PUBLIC SCHOOLS GENERAL SAFETY RULES AND REGULATIONS. This is a brief presentation on RPS General Safety Rules And Regulations
RICHMOND PUBLIC SCHOOLS GENERAL SAFETY RULES AND REGULATIONS SCRIPT: (O H = Overhead) O H 1 This is a brief presentation on RPS General Safety Rules And Regulations O H 2 Sidewalks: To ensure your safety
More information