1 Product training FLIR K series for firefighters(k45, K55, K65)
2 Disclaimer Dear Student, We kindly ask you to read the following carefully. Copyright ITC All rights reserved. This training material must not, in the whole or part, be copied, photocopied, reproduced, translated or transmitted to any electronic medium or machine readable form without the prior written permission of ITC. Names and marks appearing on the products herein are either registered trademarks or trademarks of FLIR Systems and/or its subsidiaries. All other trademarks, trade names or company names referenced herein are used for identification only and are the property or their respective owners. Legal disclaimer ITC s course material has been put together with highest diligence and according to the recognized state of the art within the field of thermography and its applications. Neither FLIR Systems nor ITC shall be liable for any direct, indirect, special, incidental or consequential loss or damage caused by eventual printing errors, changes of technology, standards and guidelines, or misinterpretations of the participant. Note/Advise Please be aware that infrared inspections of any kind- including IR image and other data acquisition, analysis, diagnosis, prognosis and reporting is a highly advanced skill. It requires professional knowledge of thermography and the specific application field, and is, in some countries, subject to certification and also legislation. Consequently, we strongly recommend that you seek the necessary training before carrying out inspections. Please visit the following sites for more information: Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
3 Content About the camera How a thermal camera works Specifications Component parts Battery Operate the buttons Screen elements, menus, and functions Camera operation Select between the modes Freeze, save, and recall images Record and view videos Change settings ConnectthecameratoaPC Change settings with FLIR Tools Transfer files Test questions - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
4 Sensing heat Whenclosetoawarmorhotobject,wecanfeeltheheatonourskin. Thedetectorofathermalcameraisalsosensitivetoheat. An electrical signal is generated and transformed into a thermal image. Figure 1 Camera principle - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
5 The thermal camera InthethermalimageoftheKseriescameras,darkermeanscolder and brighter means hotter. Figure2Twoexamplesofhowthethermalcameraseesheat - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
6 Technical specifications <1.1 kg 2mdroptested Water resistant(to IP67) Infrared resolution: K45: pixels K55andK65: pixels 60 Hz frequency Fieldofview(FOV):51 x38 2 digital zoom Two temperature ranges: 20 to +150 C(high sensitivity mode) 0 to +650 C(low sensitivity mode) Five camera modes Spotmeter, isotherm, and FSX Figure 3 K series cameras technical specifications - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
7 Specifications infrared resolution FLIR K45 ( ) Instantaneous FOV(IFOV)(at 1 m) 3.7 mm 2.9 mm 5 IFOV(at1m) 1.85cm 1.45cm Distancetoseeacat(20cmtall) 10m 14m Distancetoseeahuman(1.8mtall) 100m 125m Distancetoseeanelephant(4mtall) 200m 250m FLIR K55/K65 ( ) Figure 4 The practical implication of infrared resolution - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
8 Specifications infrared resolution At pixels (FLIR K55 or K65) you can recognize a human at a distance of up to 100 m. Figure 5 Recognizing two persons - Product training FLIR K series for firefighters (K45, K55, K65) Publ. No. T560489_35773_en-US_
9 Specifications field of view Normally our field of view(fov) is TheKseriescameralimitstheFOVto50. Figure 6 How the FOV affects your sight. Image credit: IRIS Thermovision. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
10 Specifications image frequency 60 Hz faster than the eye. True real-time information. Gives a fast, immediate overview of the situation, allowing fast action. Figure 7 Falling droplets seen with a thermal camera - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
11 Specifications FSX The K series cameras are equipped with FSX(Flexible Scene Enhancement): FSX is an advanced non-linear image-processing algorithm. FSX preserves detail in high dynamic range images. FSX extracts image details, such as edges and corners, from the original image. These details are weighted and combined with the original image. The result is an image with enhanced detail. Figure 8 Left: Image without FSX. Right: Image with FSX - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
12 Component parts FLIR K45 and K55 1. USB Mini-B connector. 2. Attachment point for the lanyard strap. 3. Eccentric latch to secure the battery. 4. On/off button. 5. Mode button. 6.Accesstosetupmenusandstoredimages:Push Mode + Zoom buttons. 7. Zoom button. 8. Connectors for the in-truck charger. 9. Save trigger. 10.Mount for a tripod adapter. 11.Attachment point for the retractable lanyard. 12.Battery. Figure9ComponentpartsoftheFLIRK45andK55 - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
13 Component parts FLIR K65 1. USB Mini-B connector. 2. Attachment point for the lanyard strap(left and right sides). 3.Latchtosecurethebattery(fastenedwithaTorx T20screw). 4. On/off button. 5. Mode button. 6.Accesstosetupmenusandstoredimages:Push Mode + Zoom buttons. 7. Zoom button. 8. Connectors for the in-truck charger. 9. Save trigger. 10.Mount for a tripod adapter. 11.Attachment point for the retractable lanyard. 12.Battery. Figure10ComponentpartsoftheFLIRK65 - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
14 Component parts battery Howtoremovethebatteryofthe FLIRK45andK55: Pull the eccentric latch. Pull out the battery. Howtoremovethebatteryofthe FLIR K65: Unscrew the Torx T20screwandpull the latch. CAUTION Donotuseatorquevalueof morethan80ncmforthe Torx T20 screw. Damage to thecameracanoccurifyou disregard this. Pull out the battery. Figure 11 Remove the battery - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
15 Charge the battery Standalone battery charger 1. Put the battery into the standalone battery charger. 2.Connectthepowersupplycableplugto the connector on the standalone battery charger. 3. Insert the power supply mains electricity plug into a mains socket. 4. Disconnect the power supply cable plug when the blue battery condition LED glows continuously. In-truck charger(optional accessory) 1.Pushthebatteryintotheslotatthelower front of the charger. 2. Secure the battery using the eccentric latch on the charger. 3.Chargingofthebatteryhasnowstarted andiscompletewhentheblueled glows continuously. NOTE The camera can also be charged directly without removing the battery using the in-truck charger. Chargethebatteryfor4hoursbeforestartingthecameraforthefirsttime,oruntilthe blue battery condition LED glows continuously. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
16 In-truck charger The in-truck charger allows the battery to be charged both when inside the camera and when removed. Thein-truckchargerisintendedtobemountedonaflatsurfaceinthecab,inone of the equipment lockers, or in another suitable compartment of the fire engine. Figure 12 In-truck charger - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
17 In-truck charger 1. Top cover. 2. LED indicator for the camera charger. 3. Hole for attaching the charger housing to the metal bracket. 4. Connectors in the cradle. 5.Connectortopowerthechargerusinga standard FLIR Systems power supply. 6. Hole for attaching the charger housing to the metal bracket. 7. LED indicator for the battery charger. 8. Battery slot. 9. Eccentric latch to secure the battery during charging. Figure 13 In-truck charger: Front view - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
18 In-truck charger 10.Cable port. 11.Routing support V DC cable plinth. 13.Recess for the cable. 14.Routing support. For recommended cable areas and the fuse, and the mounting instructions, refer to the camera s user s manual. CAUTION Disconnect the in-truck charger from the fire engine s V DC system before cleaning. The in-truck charger can be cleaned using warm water or a weak detergent solution. Do not use solvents or similar liquids. Figure 14 In-truck charger: Rear view - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
19 Camera buttons 1. On/off button a. Pushtoturnonthecamera. b. Pushandholdformorethan3seconds butlessthan10secondstoputthe camera into standby mode. c. Pushandholdformorethan10seconds toturnoffthecamera. 2. Mode button Push repeatedly to select camera modes. 3. Zoom button Zoom factor 2. 4.Push the Mode and Zoom buttons simultaneously to access setup menus and stored images. Figure 15 Camera buttons - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
20 Save trigger and lens 1. Save trigger a. Pull:Saveanimage. b. Pullandhold:Animageisfrozenuntil thetriggerisreleased.oravideois recorded. Use the Change settings menu in FLIR Toolstoenablefreezingofanimageor video recording. 2. Lens Figure 16 Save trigger and lens - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
21 Prior and after use Check the following before using the camera: 1. Make sure that the battery is inserted correctly. 2.Switchonthecamera. 3.Waitfortheimagetobedisplayed. 4. After a small click is heard(indicating the NUC(non-uniformity correction)), the cameraisreadytouse. 5. You can also toggle through the modes or check the digital temperature reading. Do the following after using the camera: 1.Switchitoff. 2.Cleanthecamerahousingwitheitherwarmwateroraweakdetergent,appliedtoa soft cloth. 3.Cleanthelenswitheither: a commercial lens-cleaning liquid with more than 30% isopropyl alcohol or 96%ethylalcohol(C 2 H 5 OH)appliedtocottonwool. 4. Charge the battery. 5.TransferimagesandvideoclipstoaPC,ifneeded. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
22 Screen elements 1. Basic mode. 2. Black and white firefighting mode. 3. Fire mode. 4. Search and rescue mode. 5. Heat detection mode. 6. Low-sensitivity indicator. 7. Overheating indicator. 8. Indicator symbol for change in the color reference. 9. Reference bar. 10.Temperature bar. 11.Spotmeter temperature. 12.Battery condition indicator. 13.Spotmeter. Figure17ScreenelementsfortheFLIRKSeries - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
23 Temperature measurement Figure 18 Incorrect temperature measurement of flames - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
24 Camera modes The K series cameras have five modes for different purposes and tasks. Figure 19 The five different camera modes They differ in the use of temperature ranges and heat colorization. Temperature ranges: Low sensitivity: 0 to +650 C(observe the indicator to the upper left). High sensitivity: 20 to +150 C. Modes with green icons: Automatic range selection. Modes with blue icons: Temperature range is locked to high sensitivity. Heat colorization: Above a certain temperature, colors are used to visualize intervals of higher(and equal) temperatures. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
25 Temperature range Low sensitivity: 0 to +650 C. High-temperature details are visible. High sensitivity: 20 to +150 C. Low-temperature details are visible. For different types of operation, one temperature range will be more suitable than the other. Figure 20 Low- and high-sensitivity range - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
26 Heat colorization Thermal images from the K series cameras use a grayscale. Heat colorization adds information about temperature. Above a threshold temperature, one or more colors are added. The additional color(s) allows hot spots or areas to be localized faster and more precisely: a. Threshold temperature. b. Lower-temperature range limit. c. Upper-temperature range limit. d. Maximum temperature in the scene. e.hottestareas:20%ofthescene. Figure 21 Principle of heat colorization - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
27 Heat colorization a. Grayscale image: Intuitive and simple image. Some details. b. Heat colorization with several colors: Region of interest showing a lot of detail. c. Heat colorization with one color: Extremely obvious location of the hottest region No details for high temperatures. Figure 22 Different types of heat colorization - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
28 Basic mode Initial fire attack with life-saving procedures and controlofthefire Automatic range selection: 20to+150 Cor 0 to +650 C. Colorization of heat: +150 to +650 C. Figure23Exampleforthebasicmode - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
29 Black and white firefighting mode Initial fire attack with life-saving procedures and control of the fire. Automatic range selection: 20to+150 Cor 0 to +650 C. Colorization of heat: None. Black and white is more intuitive than a color palette. Figure 24 Example for the black and white firefighting mode - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
30 Fire mode Initial fire attack with life-saving procedures and control of the fire. Suitable for higher background temperatures. Automatic range selection: 20to+150 Cor 0 to +650 C. Colorization of heat: +250 to +650 C. Figure25Exampleforthefiremode - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
31 Search and rescue mode Situations with lower temperatures. High-sensitivity range, locked: 20 to +150 C. Colorization of heat: +100 to +150 C. The blue Temperature bar indicates the temperature at the spot meter. Figure26Exampleforthesearchandrescuemode - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
32 Heat detection mode Searching for hot spots and thermal patterns in colder environments. High-sensitivity range, locked: 20 to +150 C. Colorization of heat: The hottest areas of the viewed scene(20% of total view). Dynamic indication. The blue Temperature bar indicates the temperature at the spot meter. Figure 27 Example for the heat detection mode - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
33 Freeze and save images Save an image: Pull the Save trigger. Freeze an image: Pull and hold the Save trigger. Record a video: Pull and hold the Save trigger. Youcansaveamaximumof200imagesin the archive. A frozen image is easier to analyze because itisnotmoving. Youcaneitherfreezeanimageorrecorda videobyholdingthesavetrigger.usethe Settings menuorflirtoolstoselectthe function. Figure 28 Save trigger functions - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
34 Recall images Enter the image archive: 1.Pushthe Modebuttonandthe Zoombuttonatthesametime. 2.Pushthe Modebuttontoenterthe archive. In the archive: 1.Pushthe Modebuttontomove forward through the images. 2.Pull the Save trigger to move backward through the images. 3.Pushandholdthe Zoombuttonto enlarge an image. 4.Pushthe On/offbuttontoexit the archive. Figure 29 Archive - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
35 Viewing saved video clips Enter the archive: 1.Pushthe Modebuttonandthe Zoombutton atthesametime. 2.Pushthe Modebuttontoenterthearchive. In the archive: 1.Videoclipsareindicatedbyafilmstripicon. 2.Pushthe Modebuttontomoveforward through the videos. 3.PulltheSavetriggertomovebackward through the videos. 4.Pushandholdthe Zoombuttontostart viewing a video. 5.Releasethe Zoombuttontostopviewinga video. 6.Pushthe On/offbuttontoexitthearchive. Figure 30 Viewing video clips - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
36 Camera settings Enter the Settings menu: 1.Pushthe Modebuttonand the Zoom button at the same time. 2. Push the Zoom button to display the Settings menu. In the Settings menu: 1. Push the Mode button to step forward. 2. Push the Zoom button to change a value. 3.Pushthe On/offbuttonto confirm and exit. Figure 31 Settings menu - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
37 Temperature indication Basic mode with Reference bar Fire mode with Temperature bar Heat detection mode with Digital read-out (measurement) a. Reference bar b. Temperature bar c. Digital read-out (measurement) Figure 32 Examples of temperature indication in different modes - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
38 ConnectthecameratoaPC FLIRK45andK55 1.Folduptherubbercoveratthe topofthecamera. 2.Holdthemetalringfirmly. 3. Rotate the ring approximately 110 counter-clockwise. 4. Pull out the plastic insert. CAUTION The plastic insert has an O-ring seal.donotdamagethisseal. 5.ConnecttheUSBcabletothe USB Mini-B connector in the connector bay. Figure33ConnectaFLIRK45orK55toaPC - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
39 ConnectthecameratoaPC FLIRK65 1.Folduptherubbercoveratthetopof the camera. 2.Foldupthemetalring. 3.UnscrewtheTorxT20screw. CAUTION Makesurethatyoudonotuseatorquevalueof morethan80ncmforthetorxt20screw.damage tothecameracanoccurifdisregardthis. 4. Pull out the plastic insert. CAUTION TheplasticinserthasanO-ringseal.Donot damage this seal. 5.ConnecttheUSBcabletotheUSB Mini-B connector in the connector bay. Figure34ConnectaFLIRK65toaPC - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
40 File transfer Drag and drop FLIR Tools Figure 35 Two options for image transfer - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
41 FLIR Tools 1. Change K series camera settings. 2. Import images from the camera. 3.Viewimagesinthelibrary. 4.Connecttoalivestream. 5. Create reports. 6. Update the camera. Figure 36 Using FLIR Tools - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
42 Changing camera settings in FLIR Tools General Settings tab 1. Regional settings: Synchronize the camera s date and time settings with the computer. 2. Firmware info area: Check for a newer version of the camera firmware. 3. Restore to factory default area: Restore all camera settings to the factory defaults. Figure 37 General Settings menu - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
43 SetuptheuserinterfacewithFLIRTools User interface tab 1. Temperature unit area. 2. Thermal indication area, select between: Digital readout only Reference bar Temp bar. 3. Save-button long press area. No action. Freeze image. Record video. 4. Auto range: The camera will automatically switch between the high-sensitivity range and the low-sensitivity range. 5. Add custom boot image. Figure 38 User interface menu - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
44 Camera operation Exercises Do the following exercises: 1. Remove(charge if needed) and insert the battery. 2.Switchthecameraonandoff. 3. Toggle the camera modes. 4.Ineachmode,observethethermalimagewhenlookingatobjectswith different temperatures. 5. In the Settings menu, change the temperature indication and observe the reference bar, the temperature reading, and the temperature bar for each mode. 6. Freeze, save, and recall images. 7.Recordandviewavideoclip. 8. Transfer images. 9. Create a simple report. 10.Clean the camera, and also the lens. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
45 Test questions 1.Whichofthefollowingliquidsshouldbeusedtocleanthecamerahousing? a. Common solvents. b. 96% ethyl alcohol. c. Warmwater. d. 50% acetone plus 50% ethyl alcohol(by volume). 2.Whatistheapproximatemaximumdistanceatwhichyoucanseeahuman beingusingaflirk45camera? a. 500m. b. 100m. c. 850m. d. 225m. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
46 Test questions 3. When would you prefer to use the high-sensitivity range? a. When the background temperature is high. b. Whenlookingforrelativelycoolobjectsinacoldenvironmentandthereisaneed to resolve small temperature differences. c. When dealing with large heights. d. Whenlookingforveryhotobjectsinacoldenvironment. 4.Inwhichsituationwouldyouusetheheatdetectionmode? a. Searching for persons in a smoke-filled room. b. Looking at a structural fire. c. Lookingforthermalpatternsontheseatsofacarafteranaccident. d. During the initial fire attack. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
47 Test questions 5. Using modes with heat colorization, what will you see with the thermal camera when the temperature is above the maximum temperature of +150 or +650 C? a. Saturation will occur, and saturated pixels will be displayed in purple. b. Heat colorization will stretch over the entire reference bar. c. The display will turn black. d. Thecamerawillswitchoff. 6.Whycanathermalcameraseeheat? a. BecauseitissensitivetoXrays. b. Becauseithasafrequencyof60Hz. c. Because the detector is sensitive to infrared radiation. d. Becauseithasaresolutionofatleast pixels. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
48 Test questions 7. What happens when infrared radiation travels through gases? a. It disappears. b. Itbecomesvisibletooureyes. c. It is unaffected. d. It is partly absorbed. 8.Howcanyouseethepreviousimageinthecameraarchive? a. By pushing the Save trigger. b. Bypushingthe Modebutton. c. By pushing the Zoom button. d. By pushing the On/off button. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
49 Test questions 9. Which of the following statements is true? Heat colorization a. overlays certain intervals of(equal) temperature with one or more contrasting colors. b. changes the temperature in the thermal image. c. depends on the object you are looking at. d. works only in closed environments. 10.Why can we look through smoke with a thermal camera? a. Because smoke is moving rapidly. b. Because smoke is essentially transparent to infrared radiation. c. Because smoke is lightweight. d. Because smoke mostly is warm. - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
50 Learn more know more ITC is the leading source within infrared science and its applications. To learn more, visit our website, take our online trainings, or attend a traditional face-to-face class. ITC EMEA websites and course calendar: ITC Americas websites and course calendar: Global ITC course schedule: ITC online training: - Product training FLIR K series for firefighters(k45, K55, K65) Publ. No. T560489_35773_en-US_
Dräger UCF 7000 Thermal Imaging Camera
Dräger UCF 7000 Thermal Imaging Camera Today, any call could potentially bring you into a hazardous area. The Dräger UCF 7000 thermal imaging camera is intrinsically safe and offers new levels of security
More informationSEE THROUGH SMOKE FROM EVERY ANGLE. FLIR Handheld, Mounted, and Aerial Thermal Imaging Cameras for Firefighting
SEE THROUGH SMOKE FROM EVERY ANGLE FLIR Handheld, Mounted, and Aerial Thermal Imaging Cameras for Firefighting IMAGE MODES FLIR THERMAL IMAGING CAMERAS FOR FIREFIGHTING FULL FORCE COVERAGE FROM THE GROUND
More informationBULLARD T4MAX THERMAL IMAGER CAMERA
BULLARD T4MAX THERMAL IMAGER CAMERA OBJECTIVES IDENTIFY ALL COMPONENTS & FEATURES OF BULLARD T4MAX DEMONSTRATE USES AND APPLICATIONS DISCUSS CARE AND MAINTENANCE DISCUSS OPERATIONAL CAPABILITIES & LIMITATIONS
More informationAvigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager
Avigilon System Integration Guide for the Avigilon Control Center and Access Control Manager 2014-2016, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, AVIGILON CONTROL CENTER,
More informationAvigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager
Avigilon System Integration Guide for the Avigilon Control Center and Access Control Manager 2014-2017, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACC, AVIGILON CONTROL CENTER,
More informationAvigilon Control Center 5 System Integration Guide
Avigilon Control Center 5 System Integration Guide for Paxton Net2 Access Control Systems 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted with
More informationCS027 User Instructions
CS027 User Instructions Battery Powered 7 Day Programmable Room Thermostat Programmable room thermostats are widely recognised as one of the best ways in which to control central heating. The CS027 programmable
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Velocity INT-HIRSCH-A-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation of this
More informationModel: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature
Model: 616-146v2 Quick Setup Guide DC: 090116 Atomic Projection Alarm with Indoor and Outdoor Temperature Snooze/Backlight BUTTONS Time, Alarm with Snooze, & Calendar Projection Arm Rotates 180 Indoor/Outdoor
More informationMood Light and Nature Sound Alarm Clock
Mood Light and Nature Sound Alarm Clock For online video support: http://bit.ly/laxtechtalk Model: C83117 DC: 031518 TABLE OF CONTENTS 3 3 4 4 4 4 5 5 5 6 6 6 6 7 7 7 7 8 8 9 9 9 9 10 10 Power Up Settings
More informationModel: Av2 Quick Setup Guide DC: Atomic Projection Alarm Clock
BUTTONS Model: 616-146Av2 Quick Setup Guide DC: 111815 Atomic Projection Alarm Clock Snooze/Backlight Time, Alarm with Snooze Projection Arm Rotates 180 Indoor Temperature + Trends Moon Phase + Calendar
More informationIllustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide
Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide 8200-1102-10 B0 Notice Please read this manual thoroughly and save it for future use before attempting to connect or operate this
More informationMonitoring Operator Guide. Access Control Manager Software Version
Monitoring Operator Guide Access Control Manager Software Version 5.10.10 2018, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER, ACM, ACM VERIFY AND TRUSTED
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation
More informationEngineering Specification
Engineering Specification Page 1 of 8 Contents PURPOSE AND SCOPE...3 VERSION HISTORY...3 GENERAL...4 DESCRIPTION OF WORK... 4 VIDEO SMOKE DETECTION CENTRAL EQUIPMENT...5 CENTRAL CONTROL UNIT... 5 SYSTEM
More informationYour competent partner for measuring and services.
Your competent partner for measuring and services. Intuitive, efficient, reliable everything for facility management: Welcome to the Smart World of Testo. 1 Too cold, too draughty, too humid? With the
More informationWEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL -
WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM10 - - OWNER S MANUAL - Thank you for purchasing the new generation of color projection clock. Designed and engineered
More informationC-Stat 17-ZW User Instructions
C-Stat 17-ZW User Instructions 7 Day Wireless Programmable Room Thermostat and ASR-ZW Receiver Programmable room thermostats are widely recognised as one of the best ways in which to control central heating.
More informationConfiguring IndigoVision Control Center. Configuring IndigoVision Control Center
Control Center Prerequisite: IndigoVision Control Center 4.7 build 25 or later Sightlogix Firmware: 5.4.6829 or later Control Center Note: This functionality is only available if you have administrator
More informationHigh Precision Digital Rain Gauge with Indoor Temperature and Humidity
High Precision Digital Rain Gauge with Indoor Temperature and Humidity Contents 1. Introduction... 2 2. Get Started... 2 2.1 Parts List... 2 2.2 Recommend Tools... 3 2.3 Installation... 3 2.4 Mount outdoor
More informationHDCVI PIR Camera User s Manual
HDCVI PIR Camera User s Manual Version 1.0.1 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Detection Range... 4 4 Device Installation... 5
More informationColour Observation System
FAR < > NEAR Colour Observation system talk action menu _ + auto next FAR < > NEAR Colour Observation Monitor Colour Observation Monitor English Colour Observation System Table of contents Page Introduction...3
More informationJOVY SYSTEMS RE-7500 User Manual Rev Index
JOVY SYSTEMS RE-7500 User Manual Rev. 1.60 Index - Introduction... 3 - Copyrights and Liability disclaimer........ 3 - Specifications.. 4 - Safety/ Caution instructions...... 4 - RE-7500 hardware description......
More informationUSER MANUAL USB Multi-Function Datalogger Model RHT35
USER MANUAL USB Multi-Function Datalogger Model RHT35 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech multi-function, easy-to-use, portable
More informationFig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.
Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems
More informationSystem Description AutroMaster V Presentation System
System Description AutroMaster V Presentation System AMASTERV-SYSTEM/XGB, Rev. B, 2018-05-07, Autronica Fire And Security AS COPYRIGHT This publication, or parts thereof, may not be reproduced in any form,
More informationUSB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger
USER MANUAL USB Multi Function Dataloggers RHT30 Humidity/Temperature Datalogger TH30 Dual Temperature Datalogger Additional User Manual Translations available at www.extech.com Introduction Thank you
More informationOperations Manual TS400. Test Station for G450/G460 Gas Detector
TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations
More informationAvigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0
Avigilon System Integration Guide Avigilon Control Center with AMAG Symmetry Security Management System 7.0 2013-2016, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, HDSM, HIGH
More informationModel: A Quick Setup Guide DC: Atomic Projection Alarm Clock
BUTTONS Model: 616-146A Quick Setup Guide DC: 070314 Atomic Projection Alarm Clock Snooze/Backlight FRONT VIEW Time, Alarm with Snooze Projection Arm Rotates 180 Indoor Temperature + Trends Moon Phase
More informationOperations Manual TS400. Test Station for G450/G460 Gas Detector
TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations
More informationTS400. Operating Manual. Test Station for Microtector II Series (G450/G460)
Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /
More informationModel: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location
Model: T83653v2 Instruction manual DC: 012916 WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location FRONT VIEW Time, Alarm + Calendar Indoor Humidity & Temperature
More informationCORAL MANTA User Guide
CORAL MANTA User Guide Copyright 208 Coral Detection Systems, all rights reserved. Rev B Doc P/N: xxxx 2. Contact Information For help with this device, please contact Coral Detection Systems at: Website
More informationDEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes
DEFECTOVISION IR Non-Destructive Testing of Steel Billets and Tubes FOERSTER DIVISION TESTING SYSTEMS (TS) The Company FOERSTER is a global technology leader for nondestructive testing of metallic materials.
More informationPrecision Infrared Thermometer. Users Manual
Precision Infrared Thermometer Users Manual March 2005 2005 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev2 Copyright 2011 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation
More informationEnglish. FCC declaration. Electro Magnetic Compatibility (EMC) Warning. This device complies with part 15 of the FCC rules.
English FCC declaration Warning: To prevent fire or shock hazard, do not expose camera or monitor to rain or moisture. The lightning flash with arrowhead symbol, within a triangle, is intended to alert
More informationCAN unit for Analog Sensors
CAN unit for Analog Sensors Didactum`s Monitoring Systems have many uses: Monitoring of wring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power
More informationAvigilon Control Center System Integration Guide
Avigilon Control Center System Integration Guide with Picture Perfect 4 INT-PP4-A-Rev1 Copyright 2012 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation
More informationAtomic Projection Alarm Clock
Model: 616-143 Quick Setup Guide DC: 072915 Atomic Projection Alarm Clock Snooze/Backlight Projection Lens Projection Arm Rotation (Front and Back) FRONT VIEW Buttons Projection Focus BACK VIEW AC Power
More informationMilestone XProtect Alarm Matrix Integration 1.0
Milestone XProtect Alarm Matrix Integration 1.0 Milestone XProtect Alarm Matrix Integration 1.0 Target Audience This document is aimed at system users and provides descriptions on how to install, configure
More informationTruVision Bullet IR Camera Pocket Guide
GE Security TruVision Bullet IR Camera Pocket Guide g 1065696A Copyright Disclaimer Trademarks and patents Intended use Copyright 2008 GE Security. All rights reserved. This document may not be copied
More informationDatasheet Crowd Management
Datasheet Crowd Management Version 3.78 This Specification Sheet gives the details of system requirements, feature details and other salient points of AllGoVision s Crowd Management applications. Revision
More informationPROFESSIONAL DRIVER FATIGUE MONITOR
PROFESSIAL DRIVER FATIGUE MITOR RVS-350P User Manual Product Composition *RVS-350P includes the host and 5 pin signal line. It can work on all types of vehicle, both 12V and 24V power supply. Caution Do
More informationSecurity Management System - Configuring Video Analytics
Introduction This document describes the steps for configuring the Video Analytics (VA) module available in the Security Management System software. Security Management System video analytics module is
More informationSmoke Detector and Siren. Manual
Smoke Detector and Siren Manual 004001 Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device...
More informationTypical applications include the vibration detector. Detection of vibrations and shocks
Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems
More informationstatus AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.
status 2016 Chuango. All Rights Reserved. Printed in China PA : AW1-UM-EN-V1.0 AW1 WiFi Alarm System User Manual Foreword Contents Congratulations on your purchase of the AW1 Alarm system. Before you commence
More informationOutdoor Temperature Sensor
Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems
More informationModel: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight
Model: 616-143 Quick Setup Guide DC: 083017 Atomic Projection Alarm Clock Snooze/Backlight Projection Lens Projection Arm Rotation (Front and Back) Buttons Projection Focus 5.0 VAC Power Jack 616-143 www.lacrossetechnology.com/support
More informationEasyLog Data Logger Series
EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line
More informationHDAVS ICR IR Water proof Dome Camera User s Manual
HDAVS ICR IR Water proof Dome Camera User s Manual Version 1.0.0 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Installation... 3 4 Menu...
More informationTruVision Bullet IR Camera Pocket Guide
GE Security TruVision Bullet IR Camera Pocket Guide EN FR DE IT NL ES PT PL g 1065697A Copyright Disclaimer Trademarks and patents Intended use Copyright 2009 GE Security. All rights reserved. This document
More informationOwner s Manual. PIR-1 IR Learner
Owner s Manual PIR-1 IR Learner PIR-1 Owner s Manual 2010-2013 Universal Remote Control, Inc. The information in this owner s manual is copyright protected. No part of this manual may be copied or reproduced
More informationWiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title
WiFi Hints & Tips Contents Page No. Section No. Title Section.0 System Set-Up 3 Section. Sensor Set-Up 4-5 Section. Sensor Set-Up (Configuring Network) 6-9 Section.3 Sensor Set-Up (Configuring Settings)
More informationMillennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.
Millennium Xtra Millennium ATMA setup and configuration guide May 16 2017 Millennium Group, Inc. 16 Tech Circle Natick, MA 01760 P: 508-655-1340 F: 508-651-2902 Millennium ATMA setup and configuration
More informationCombined CAN Sensor Unit Temperature, Humidity and Smoke
Combined CAN Sensor Unit Temperature, Humidity and Smoke Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical
More informationWelcome to MultiSight TM Vision Sensor Hands-On Lab
Welcome to MultiSight TM Vision Sensor Hands-On Lab About This Hands-On Lab Welcome to the MultiSight TM Vision Sensor Hands-On Lab! This session provides you with an opportunity to explore the functionality
More informationQUICK START. FLIR Model MR59. Ball Probe Moisture Meter with Bluetooth
QUICK START FLIR Model MR59 Ball Probe Moisture Meter with Bluetooth MR59 - QUICK START - EN To obtain the detailed User Manual please visit http://support.flir.com (download tab). Please read the user
More informationModel: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight
Model: 616-143 Quick Setup Guide DC: 051916 Atomic Projection Alarm Clock Snooze/Backlight Projection Lens Projection Arm Rotation (Front and Back) Buttons Projection Focus 5.0 VAC Power Jack Battery Cover
More informationModel 3300 Technical Support and Installation Manual
Model 3300 Technical Support and Installation Manual Manual # T15011 Document Revision: A1 1. OVERVIEW 1 2. BASIC OPERATION 1 2.1 General 1 2.2 Field-of-View 2 2.3 Range 2 2.4 Environment 2 2.5 Configuration
More informationDatasheet Face Recognition [Genetec VMS]
Datasheet Face Recognition [Genetec VMS] Version 3.6 This Specification Sheet gives the details of system requirements, features and other salient points of AllGoVision Face Recognition application for
More informationDual Spin Mop Robot Cleaner
Dual Spin Mop Robot Cleaner Copyright 2017 EVERYBOT Inc. All rights reserved. This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by any
More informationUser Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs
User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents
More informationCeiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver
Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with
More informationstatus AW1 Plus WiFi Alarm System User Manual
status AW1 Plus WiFi Alarm System User Manual Foreword Congratulations on your purchase of the AW1 Plus Alarm system. Before you commence installation we recommend that you unpack the product, familiarise
More informationNotice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...
Table of Contents Preface 1 Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty... 2 Chapter 1 Radius Overview 6 1.1 About
More informationAlarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9
Alarm Client Installation and User Guide NEC NEC Corporation May 2009 NDA-30364, Revision 9 Liability Disclaimer NEC Corporation reserves the right to change the specifications, functions, or features,
More informationAutomated Infrared Thermography Complete Solutions from a Single Source
Automated Infrared Thermography Complete Solutions from a Single Source Temperature monitoring of processes Automatic surveying of thermal marks Early fire detection and site security www.infratec.eu Innovative
More informationDC200 Digital Dispenser Operating Manual
DC200 Digital Dispenser Operating Manual 2015 Fisnar Phone: (973) 646-5044 E-mail: info@fisnar.com Table of Contents Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine
More informationUser s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB
User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB Copyright 2016 This manual is furnished under license and may be used or copied only in accordance with the terms of such license.
More informationWall Hung Boiler Room Thermostat OR30 OT Thermostat
8 733 201 137-00.1O Wall Hung Boiler Room Thermostat OR30 OT Thermostat Operating Instruction 6 720 812 418 (2014/07) en 2 Contents Contents 1 Symbols and safety precautions..................................
More informationDual Laser InfraRed (IR) Thermometer
User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42512 Introduction Congratulations on your purchase of the Model 42512 IR Thermometer. This Infrared thermometer measures and displays non-contact
More informationDEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual
DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual Document Number: 057-159 Author: Fady Atallah DSE94xx Configuration Suite PC Software Manual ISSUE 15 DSE94xx
More informationDashboard for Windows V1.1.0
User manual Dashboard for Windows V1.1.0 TBS Electronics BV De Factorij 46 1689 AL Zwaag The Netherlands www.tbs-electronics.com COPYRIGHT 2009 (rev1e) - 1 - TABLE OF CONTENTS 1. INTRODUCTION......................
More informationUser Manual LIGHTMEN.COM. Apollo A75050
User Manual LIGHTMEN.COM Apollo A75050 TABLE OF CONTENTS 1 Introduction... 3 1. 1 Maintenance... 4 1.2 Operating elements and connections... 5 1.3 Menu button overview... 5 1.4 Operating elements and connections
More informationNON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL
NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL VR40 Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction.........................
More informationIntelliDoX Operator Manual
IntelliDoX Operator Manual OPERATOR MANUAL TABLE OF CONTENTS Table of Contents Table of Contents...1 About this Publication...3 Important Safety Information: Read First...4 Getting Started...5 About the
More informationMini InfraRed (IR) Thermometer with Type K Input and Laser Pointer
USER MANUAL Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer MODEL IR267 Introduction Thank you for selecting the Extech Model IR267 Mini IR Thermometer. The Model IR267 IR thermometer
More informationCompact, high-power, outdoor-rated, cable-free, battery-powered LED uplight with onboard wireless DMX, infrared remote, and manual control via OLED function menu + Six-unit road-worthy custom charging
More informationUSER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual.
USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor User Manual 8690 Rev B Update: 10/24/2013 1 Table of Contents 1 Introduction.. 3 2 Host
More informationRecording Server PRELOADED
Configuration English Recording Server PRELOADED Rev. 1.1.2 / 2015-12-09 Module BANK Information about copyright, trademarks, design patents 2015 Dallmeier electronic The reproduction, distribution and
More information4-IN-1 PIN/PAD RH MOISTURE METER
4-IN-1 PIN/PAD RH MOISTURE METER USER S MANUAL MMH800 Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction................................ 3 4 Key
More informationOntech GSM 9040/50. Reference Manual English -1 -
Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7
More informationWIRELESS COLOR FORECAST STATION
Model: 308-1412S Manual DC: 080217 WIRELESS COLOR FORECAST STATION SENSOR TX141TH-Bv2 LED TX Sensor Battery 2 AA Buttons 3 AAA AC Power USB PORT Model: 308-1412S www.lacrossetechnology.com/support Page
More informationIndigoVision Alarm Panel. User Guide
IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE
More informationDry Contact Probe DCP (#30008)
Dry Contact Probe DCP (#30008) The Networked Robotics DCP probe enables network data collection of the state of any normally open or normally closed switch. This product can sense alarm contact outputs
More informationMWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features
Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual
More information64 Max IR Thermometer
64 Max IR Thermometer Users Manual January 2017 2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
More informationE529 Smart Digital Thermostat Product Guide
E529 Smart Digital Thermostat Product Guide Table of Contents Table of Contents... Page 1 Overview and General Concept... Page 2 Application... Page 3 Features... Page 4 LCD Item Descriptions... Page 5
More informationWARRANTY Sper Scientific warrants this product against defects in materials and workmanship for period of one (1) Year from the date of purchase and agrees to repair or replace any defective unit without
More informationM210 Multifunction Micro OTDR
Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New
More informationUsers Manual. Visit us at
Users Manual 568 EX Infrared Thermometer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com PN 4326622 June 2013 2013 Fluke Corporation.
More informationAtomic Projection Alarm. Model: A Instruction Manual
Atomic Projection Alarm Model: 616-146A Instruction Manual Introduction The Atomic Projection Alarm features radio-controlled time, indoor temperature, and moon phase on a simple, and easy to read display.
More informationAtomic Digital Wall Clock
Model: BBB87269 Instruction Manual DC:102015 Atomic Digital Wall Clock Table of Contents Welcome... Get Started... Button Functions... Settings: Time, Date, etc.... Time Zone Settings and 12/24 Hour Time...
More informationSpa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)
Spa Touch Control Panel with 2000, 2100 controllers (Spa Owner s Manual insert) P.N. 7876B February 11, 2015 For Spas equipped with BP2000, BP2100 controllers and Spa Touch panel. Spa Touch Control Panel
More informationLUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers
LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL October 2014 Serial Number 25000100 and Succeeding Serial Numbers LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL October
More informationWireless Weather Station. Table of Contents
Wireless Weather Station Model: T83646v2 Instructional Manual DC:071916 For online video support: http://bit.ly/laxtechtalk Table of Contents LCD Features... Buttons... Setup... Set Time, Date etc....
More informationC-Bus Pascal Automation Controller 5500PACA. Installation Instructions
C-Bus Pascal Automation Controller 5500PACA Installation Instructions Contents 1.0 Description...3 2.0 Important Notes...3 3.0 Capabilities...3 4.0 Wiring Instructions...4 4.1 Battery Back up...5 4.2 Connecting
More information