Buyer s Guide Warning Lights FAMA BUYER S GUIDE TC044. Warning Lights. Prepared by the FAMA Electrical Subcommittee

Similar documents
Buyer s Guide Scene Lighting FAMA BUYER S GUIDE TC037. Scene Lighting. Prepared by the FAMA Electrical Subcommittee

NFPA 1901 Specification. Lighting Packages

CITY OF OWENSBORO OWENSBORO FIRE DEPARTMENT DEPLOYMENT ANALYSIS

Art, Wall Decor, Picture Frame & Custom Framing Report, 2013

Overview of Process for Certification to NFPA Standards for Fire and Emergency Services PPE. IOM Workshop on Certification of PPT April, 13, 2010

Mutual Aid Box Alarm System Illinois Communications MABAS BOX ALARM CARDS

Centers for Regional Excellence. Downriver Fire Authority. Organization Committee Objective. Operations Committee Report 2007

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

NFPA. How to Nail. Your First-Due Responsibility. Part 2: What the Standards Recommend

HOUZZ: GUIDELINES + BEST PRACTICES FOR BUSINESSES

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

An Approach to First Responder Radiological Preparedness Tom O Connell and Paul Ares

Pebble Beach Community Services District Fire Department 3101 Forest Lake Road, Pebble Beach, CA

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

SPECIALISTS IN INDUSTRIAL PROTECTION

Firefighters Support Foundation. v1 1

LIGHTING Solutions. 7 Round LED Headlight w/ Heated Lens 27275C. Portable Magnetic Base LED Beacon SL475A

INSTALLATIONGUIDE. HotSeam TM Overview ICE ROOF

Recent and Upcoming Changes in the ANSI Z136 Series of Standards for Safe Use of Lasers

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

ICARO Aircraft Warning Lights

Transition to a New Hazard Based Safety Standard, IEC

Home Staging Action Kit

SMALL TOOL REPLACEMENT PLAN

Safety Function: Single-beam Area Access Control (AAC)

Date: April 19, 2017 Community Development and Recreation Committee Fire Chief and General Manager, Fire Services

Operation and Maintenance Manual OM 897-3

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance.

MASH Implementation for Guardrail

Services the Agency is Required to Provide Services

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Fluke-Direct.com

End To End Optical Beam Smoke Detector. Additional Information

WHITE PAPER. Standard Product Safety Sign Catalog for Automotive Fire Apparatus RATIONALE

Installation Guide. Disabled Persons Emergency Alarm Kit. Single Zone Call Control/Call answered unit c/w Sounder LED indicators and Braille lettering

ReCollections Volume 5 / Issue

ISO Textiles Domestic washing and drying procedures for textile testing

Nuclear Power Plant LSZH Cable Overview

STROBE POWER SUPPLIES - two outlets by Tomar Electronics

As firefighters dismounted their apparatus, they recognized the life hazard that was presented. WNYF 2 nd issue 1967

CITY OF MOUNTAIN BROOK FIRE DEPARTMENT

Blind Spot Safety Solutions

LESSON PLAN TOUCHCAST USAGE IN EDUCATION

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

California. Approved LED Products.

2G & 3G GSM Wireless Beam Alarm

Evacuate everyone Sonos Pulse & Nexus Pulse

Authorization to Purchase one Pierce Velocity PUC Pumper NH657 Fire Engine

INTERNATIONAL STANDARD

LED VISOR LIGHT INSTALLATION & OPERATION MANUAL IMPORTANT: Contents:

Thermo-Electric for short trips

onlinecomponents.com

Annual Report Components

Warning Lamps WARNING LAMPS. 10 WELDON PH ( ) FAX " WARNING LAMPS

M E M O R A N D U M. Please do not vote negatively because of editorial errors. However, please bring such errors to my attention for action.

Monthly Report for November 2017

INTERNATIONAL ASSOCIATION OF FIRE FIGHTERS

SENSOR SOLUTIONS FOR DOORS

ISO INTERNATIONAL STANDARD. Intelligent transport systems Devices to aid reverse manoeuvres Extendedrange backing aid systems (ERBA)

Dräger UCF 7000 Thermal Imaging Camera

Tire Storage. Michigan Fire Inspectors Society Fall Conference

Lighting Controls An Introduction and Review

Sales FAQ. Paradox Insight - General. 1. What is Paradox Insight?

Excelsior Fire District Aerial 11 Key Questions

Professional Security Officer Program(PSOP)

Vehicle Detection: How To Choose the Right Technology... 3

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

SENSOR SOLUTIONS FOR DOORS

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

polar zone components and systems for extreme temperatures

AIRCRAFT RESCUE AND FIREFIGHTING

Chapter 1 Test. Directions: Write the correct letter on the blank before each question.

# Thorton s Gas Station Conceptual PUD Project Review for Planning and Zoning Commission

JUNE NEWSLETTER- FALLIING OBJECTS

Different types of Fire Alarm System

Overview Alliance Medical Gas Corporation is a privately held organization that was founded on January 1, 1996 with the vision to be a single-source,

The Basics Arc Flash Protection

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

Fire and gas safety systems:

Mission. Vision. To set the standard for excellence and innovation in public safety. Department Description

TIME TO PRIME, by Rich Teske

Pulse Firing Doubles Capacity and Cuts Fuel Costs

NFPA Electronic Safety Equipment Standards What s happening now!

Thank you for choosing the Minquas Fire Company for your child s birthday party! A party at the fire house will not only be fun, but educational.

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

Newfoundland and Labrador Association of Fire Services PMA Conference St John s April 23,

Vigilant LED Based Obstruction Lights

Stage 1 Audio Upgrade (BMW Speakers) Installation Instructions for BMW 5 Series, E60 Sedan Logic 7

Wanting to renovate your kitchen and don t know where to start? Follow these simple steps Verona recommends.

A holistic view on the charm and challenge of CENELEC standards for railway signaling Restricted Siemens AG 2016 All rights reserved.

GARN WHS 3200 Addendum to the Owner s Manual

IXIUM. DVR Smoke Alarm. User Manual

2013 Compliance Report RCW 52.33

NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure.

* A person would be visible from a greater distance at nighttime than during daytime. At nighttime their heat / IR signature would be greater than

La Veranda Summary Notes from DRAC meeting 4/05/16

Understanding NFPA, NEC 2005 Article 409 a White Paper by Paul A. Terry, P.E.

Transcription:

FAMA BUYER S GUIDE TC044 Prepared by the FAMA Electrical Subcommittee This guide does not endorse any manufacturer or product Page 1 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

Contents Introduction...3 Overview...3 Apparatus...3 Large Apparatus... 3 Small Apparatus... 4 Flash Rate & Failure Minimums... 4 Operation Modes... 5 Permissible Colors... 5 Light Energy Requirements... 6 Large Apparatus...6 Small Apparatus...7 Zones...8 ZONE A... 8 ZONE C... 9 ZONES B&D... 10 Page 2 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

Introduction There are many choices to be made for Fire Truck when purchasing your new apparatus. The goal of this buyer s guide is to help with those choices and make that decision-making process much easier. Overview When considering for your new apparatus there are several factors to take into consideration. It is important for you or your committee to completely understand what guidelines have to be met for your new apparatus to be NFPA compliant. The following sections will touch on all those factors that need to be considered for Fire Truck Emergency Lights along with some application photos that can be beneficial when it comes to specifying your new apparatus. We will look at this in detail as we move forward. Apparatus The first determination for you or your committee will be the size of your apparatus. NFPA breaks this into two categories, Large Apparatus & Small Apparatus. Let s take a look at the Large Apparatus first. LARGE APPARATUS A large apparatus is defined in NFPA 1901 as an apparatus with a bumper-to-bumper length of 25 feet or more. The upper-level optical warning devices shall be mounted as high and near the corner points of the apparatus as is practical. The lower-level devices shall be between 18 inches and 62 inches above level ground. (we will touch on the zone configurations along with upper/lower level in the next section). A mid-ship optical warning device shall be used if the distance between the front and rear lowerlevel optical devices exceeds 25 feet. Page 3 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

The minimum optical warning system should require no more than an average of 40 amps when operating in the blocking mode (we will cover modes later in this section). Should the apparatus require mid-ship lights, no more than 5 amps of additional current should be required for operation of each set of mid-ship lights. See the NFPA 1901 standards guide for more information and load management demand questions. More mid-ship lights needed: Additional mid-ship lights must be added to lower B & D zones on a large apparatus so that you always maintain a horizontal distance of 25 feet or less between all centers of the lower level warning lights. Below is a minimum midship lighting example for Zones B & D. SMALL APPARATUS A Small Apparatus is defined in NFPA 1901 as an apparatus whose bumper-to-bumper length is less than 25 feet. The upper-level warning devices should be mounted high, but not over 8 feet, at the optical center. One or more lower-level warning devices shall be mounted close to the front corner(s) of the apparatus with the distance between 18 inches and 48 inches from the ground. The minimum optical warning system should require no more than an average of 35 amps when operating in the blocking mode. See the NFPA 1901 standards guide for more information on load management demand questions. FLASH RATE & FAILURE MINIMUMS It is important to take into account your Flash Rate & Failure minimums for each size apparatus. For Large & Small Apparatus the Flash Rate & Failure minimums are as follows: 75 flashes per minute is the minimum flash rate allowed for a single optical source 150 flashes per minute from all the light sources visible at any data point (i.e. two warning lights are required per zone). Failure of a lighting product should not leave a zone area without a lighting source. Page 4 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

OPERATION MODES There are two operation modes when running your apparatus, they are: Calling for Right of Way (Responding) apparatus responding to an emergency Blocking Right of Way (At Scene) Blocking right of way, white light not permitted PERMISSIBLE COLORS There are permissible Warning Light colors in both Calling for Right of Way & Blocking Right of Way that have to be taken into account when considering your Warning Light selection. The following table lists the permissible colors in both Modes: Page 5 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

LIGHT ENERGY REQUIREMENTS There are minimum Light Energy Requirements that have to be met for both Large & Small Apparatus. The following tables show those levels so the correct Warning Light Package can be determined: Large Apparatus Page 6 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

Small Apparatus Page 7 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

Zones There are four zones that you have to take into consideration when specifying your apparatus. These consist of Zones A, B, C, & D. It is also important to remember that each zone is broken into an Upper and Lower level as well. So, in total, there are eight zones that have to be addressed. The following diagram shows an overview of each main Zone on an apparatus: ZONE A Per the above diagram, Zone A is going to be the forward facing direction on your apparatus. The Upper portion of Zone A usually consists of some form of light bar. Here are a couple examples of light bars in Upper Zone A on apparatus: Page 8 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

Lower Zone A usually will consist of 2-4 Perimeter Lights or Directional Lights. ZONE C Again, referring back to the diagram, Zone C is going to be your rear facing direction on your apparatus. Upper Zone C can consist of many different light configurations to be compliant per NFPA standards. Some of your most popular options for Upper Zone C are going to be Beacons, Mini Bars, & Perimeter Lights. Pictured are examples of each: Beacons Mini Bars Perimeter Lights Page 9 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

Lower Zone C will usually consist of Perimeter Lights or Directional Lights. ZONES B&D One last time referring back to the diagram, Zones B & D are going to be the sides of your apparatus. With Zones B & D, their lighting packages will almost always mirror one another. When it comes to Upper Zones B & D, it is usually standard to place Perimeter Lights in this area to obtain a compliant lighting package. Depending on what brand lights are installed, where they are installed, & what size lights will determine how many lights are needed. Your apparatus manufacturer will determine how many lights are needed to be NFPA compliant. Here are some examples of Perimeter Lights: Page 10 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

Lower Zones B & D will also usually entail some form of Perimeter or Directional Lights. Here are some examples: Finally, in some instances, lights from one zone will also cover another zone for NFPA compliance. In the following diagram we will take a look at how that can happen: Page 11 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

As you can see, there are many determining factors that go into the decision making process for the selection of a Warning Light Package. Use of this guide will help make that task much less daunting. Make sure you use the expertise of the Warning Light Page 12 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404

Manufacturer along with the OEM who builds your apparatus to help with any questions you may have along the way. Both of these outlets can be very beneficial to you as you move forward. Page 13 of 13 Fire Apparatus Manufacturers Association TC044 - Buyers Guide - 18040404