DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual Document Number: 057-159 Author: Fady Atallah DSE94xx Configuration Suite PC Software Manual ISSUE 15
DSE94xx Configuration Suite PC Software Manual DEEP SEA ELECTRONICS PLC Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723 890099 Sales Fax: +44 (0) 1723 893303 E-mail: sales@deepseaplc.com Website: www.deepseaplc.com DSE94xx Configuration Suite PC Software Manual Deep Sea Electronics Plc All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder except in accordance with the provisions of the Copyright, Designs and Patents Act 1988. Applications for the copyright holder s written permission to reproduce any part of this publication should be addressed to Deep Sea Electronics Plc at the address above. The DSE logo is a UK registered trademarks of Deep Sea Electronics PLC. Any reference to trademarked product names used within this publication is owned by their respective companies. Deep Sea Electronics Plc reserves the right to change the contents of this document without prior notice. Amendments List Issue Comments 1 Initial release 2 Amendments of 9472, 9480, 9481 3 Amendments of 9470 & 9480 V2.0 New features added: - Digital Input - Default Voltage Mode - Battery Profile - Configurable Gencom 4 Amendments for 9474 V1 and 9470/2 & 9480/1 V3.0 5 Amendments to cover the DSE9484 V1 and DSE9450 V1 6 Added the DSE9473 and DSE9483 battery chargers 7 Added DSE9452 8 Added DSE9462 dual output charger 9 Added DSE9479 10 DC Overvoltage Alarm removed from DSE9462, Configurable Short Circuit Alarm added to DSE9452 11 Updated battery profile image to show Bulk Trigger and Absorption Voltage. 12 Added DSENet configuration. 13 Amendments to DSENet options. 14 Updated for the DSE9473 new features (Soft Start, and Battery Self Test Range) 15 Updated to add the Stage Voltage Levels for all charger models 2
DSE94xx Configuration Suite PC Software Manual Typeface: The typeface used in this document is Arial. Care should be taken not to mistake the upper case letter I with the numeral 1. The numeral 1 has a top serif to avoid this confusion. NOTE: CAUTION! WARNING! Highlights an essential element of a procedure to ensure correctness. Indicates a procedure or practice which, if not strictly observed, could result in damage or destruction of equipment. Indicates a procedure or practice which could result in injury to personnel or loss of life if not followed correctly. Deep Sea Electronics Plc owns the copyright to this manual, which cannot be copied, reproduced or disclosed to a third party without prior written permission. 3
DSE94xx Configuration Suite PC Software Manual TABLE OF CONTENTS 1 BIBLIOGRAPHY... 5 2 DESCRIPTION... 5 3 INSTALLATION AND USING THE DSE CONFIGURATION SUITE... 5 4 EDIT CONFIG... 6 4.1 SCREEN LAYOUT... 6 4.2 CHARGER... 7 4.2.1 DIGITAL INPUT SELECTIONS... 8 4.2.2 CABLE VOLTAGE DROP... 8 4.2.3 BATTERY CHARGER SELF TEST... 8 4.2.4 CHARGER FAILURE... 9 4.2.5 SHORT CIRCUIT ALARM... 9 4.2.6 SOFT START... 9 4.3 BATTERY...10 4.3.1 BATTERY SETTINGS...10 4.3.2 BATTERY PROFILE...11 4.3.3 OVER CURRENT ALARM...12 4.3.4 UNDER VOLTAGE ALARM...12 4.3.5 OVER VOLTAGE ALARM...13 4.3.6 BATTERY DETECTION...13 4.4 MAINS...14 4.4.1 MAINS VOLTAGE ALARMS...14 4.5 COMMUNICATIONS...15 4.6 CONFIGURABLE GENCOM...16 5 SCADA... 17 5.1 ALARMS...18 5.2 INSTRUMENTATION...19 5.3 MODULE...20 4
Bibliography 1 BIBLIOGRAPHY This document refers to and is referred to by the following DSE publications which can be obtained from the DSE website www.deepseaplc.com: DSE PART DESCRIPTION 053-049 DSE9000 Series Battery Charger Installation Instructions 057-085 DSE900 / 9100 / 9200 / 9400 Series Battery Charger Operator Manual 053-147 DSE9460 / DSE9461 Installation Instructions 057-176 DSE9460 / DSE9461 Operator Manual 053-175 DSE9474 / DSE9484 Installation Instructions 057-231 DSE9474 / DSE9484 Operator Manual 053-178 DSE9450 & DSE9452 & DSE9479 Installation Instructions 057-240 DSE9450 & DSE9452 Operator Manual 053-185 DSE9473 / DSE9483 Installation Instructions 053-189 DSE9462 Installation Instructions 057-255 DSE9462 Operator Manual 057-264 DSE9479 Operator Manual 2 DESCRIPTION This manual covers the operation of the DSE Configuration Suite for DSE94xx (DSE9460, DSE9461, DSE9470, DSE9472, DSE9473, DSE9474, DSE9480, DSE9481, DSE9483, DSE9484, DSE9450, DSE9452, DSE9462 & DSE9479) battery chargers. Separate manuals cover the remaining DSE modules supported by the software. The DSE Configuration Suite allows the DSE9400 series to be connected to a PC via USB A USB B cable. Once connected the various operating parameters within the charger can be viewed or edited as required by the engineer. This software allows easy controlled access to these values and also has diagnostic monitoring facilities. The DSE Configuration Suite should only be used by competent, qualified personnel, as changes to the operation of the module may have safety implications on the panel to which it is fitted. The information contained in this manual should be read in conjunction with the information contained in the appropriate module documentation. This manual only details which settings are available and how they may be used. A separate manual deals with the operation of the charger (See section entitled Bibliography elsewhere in this document). 3 INSTALLATION AND USING THE DSE CONFIGURATION SUITE For information in regards to installing and using the DSE Configuration Suite Software please refer to DSE publication: 057-151 DSE Configuration Suite PC Software Installation & Operation Manual which can be found on our website: www.deepseaplc.com 5
DSE94xx Configuration Suite PC Software Manual 4 EDIT CONFIG This menu allows module configuration, to change the function of Inputs, Outputs and LED s, system timers and level settings to suit a particular application. 4.1 SCREEN LAYOUT NOTE: The Charger Output 2 and Battery 2 sections are only available for the DSE9462 battery charger. The type of configuration file being edited Move to the Previous or Next configuration page The coloured shading shows the currently selected page. Close this configuration file Click + or to show or hide the sub settings within each sections. Click to select the subsection to view / edit 6
Edit Configuration 4.2 CHARGER Free entry boxes to allow the user to give the configuration file a description. Typically this is used to enter the job number, customer name, engineers name etc. Select the output voltage of the charger. Not available for DSE9450, DSE9452, DSE9462, DSE9473, DSE9474, DSE9479, DSE9483 and DSE9484 Applicable on the DSE9473 only. Enable the battery voltage sensing wires. Only available for DSE9450, DSE9452, DSE9462, DSE9474, DSE9479, and DSE9484 Enable or disable the alarms. The relevant value below appears greyed out if the option is disabled. Only available for DSE9450, DSE9452, DSE9462, DSE9474, DSE9479, and DSE9484 Type the value or click the up and down arrows to change the settings Not available for DSE9450, DSE9452, DSE9462, DSE9474, DSE9479, and DSE9484 Parameters are detailed overleaf. Not available in the DSE9450 configuration 7
Edit Configuration 4.2.1 DIGITAL INPUT SELECTIONS Parameter Charger Off Enable Battery Detection Lamp Test Manual Boost Switch To Alternative Voltage Mode Description This input turns off the charger output When active, the battery charger detects the presence of the battery and illuminates its LEDs to indicate the status. This input illuminates all on board LEDs This input forces the charger into boost mode This input switches the output voltage to the alternative mode i.e. if the default voltage mode is set to 12V, activating this input changes the output voltage to 24V. 4.2.2 CABLE VOLTAGE DROP NOTE: Only available when the battery charger is connected to the battery with no active alarms and the mains supply is available. Parameter Alarm Alarm Delay Return Return Delay Description Only available for DSE9450, DSE9452, DSE9474, DSE9479, and DSE9484 The alarm activates when the voltage difference between the battery charger output and the Battery Voltage Sensing terminals exceeds the Alarm trip setting for longer than the Alarm Delay duration. Only available for DSE9450, DSE9452, DSE9462, DSE9474, DSE9479, and DSE9484 The alarm is deactivated when the voltage difference between the battery charger output and the Battery Voltage Sensing terminals falls below the Return setting for longer than the Return Delay time. 4.2.3 BATTERY CHARGER SELF TEST NOTE: Battery Charger Self Test is not available on the DSE9462 Intelligent Battery Charger. Parameter Enable Self Test Timer Description = Feature disabled. = The battery charger performs a self test in a regular interval set by the Self Test Timer. The alarm activates when an internal failure is detected. Set the time interval between the Battery Charger Self Test runs. 8
Edit Configuration 4.2.4 CHARGER FAILURE Parameter Alternative Charge Source Delay Description = The Alternative Charge Source is disabled and the Charger Failure Alarm activates when the battery charger measures a voltage higher than its output voltage. The alarm is delayed by the configurable Delay timer. This is useful when the battery charger switches from Bulk mode to Float charging mode, as the battery voltage remains higher than the battery charger output voltage for a short amount of time. = The Alternative Charge Source is enabled and the Charger Failure Alarm no longer activates when the battery charger measures a voltage higher than its output voltage. This is useful when a DC Alternator is fitted on the engine and supplies a voltage higher than the battery charger. When the Alternative Charge Source is disabled, this sets the time delay for the Charger Failure Alarm. 4.2.5 SHORT CIRCUIT ALARM NOTE: Not available in the DSE9450 Intelligent Battery Charger s configuration. Parameter Enable Delay Description = The Short Circuit Alarm is disabled; however the battery charger switches its output off when a short circuit is detected. = The Short Circuit Alarm is enabled and activates when a short circuit is detected for longer than the configurable Delay timer. Set the time delay for the Short Circuit Alarm. This is useful to delay the alarm when the engine crank motor is engaged; the battery charger detects the current drawn by the crank motor as a short circuit. In this case, the charger immediately switches its output off for protection but the alarm is delayed. 4.2.6 SOFT START NOTE: Available only on the DSE9473 Intelligent Battery Charger. Parameter Enable Description = The Soft Start is disabled. = The Soft Start is enabled. The charger rises its output voltage to the required DC voltage level in steps, and takes longer time to reach the maximum output voltage level. This feature helps to reduce the inrush current caused by the capacitive loads or deeply discharged batteries. 9
Edit Configuration 4.3 BATTERY The inputs page is subdivided into smaller sections. Select the required section with the mouse. 4.3.1 BATTERY SETTINGS Enable or disable the external Battery Temperature Sensor (PT1000). The relevant values below appear greyed out if the option is disabled. Type the value or click the up and down arrows to change the settings Click and drag to change the settings Over Temperature Alarms Alarm Alarm Delay Return Return Delay The alarm activates when the battery temperature exceeds the Trip value setting for longer than the Trip Delay time duration. The alarm is deactivated when the battery temperature falls below the return value setting for longer than the Return Delay duration. Voltage Compensation / C NOTE: For further information on the temperature compensation, refer to the product s Operator Manual which can be found on our website: www.deepseaplc.com Set the variation of the charger output voltage for each degree Celsius of temperature change. This is normally specified by the battery manufacturer. 10
Edit Configuration 4.3.2 BATTERY PROFILE NOTE: For a 2-Stage charging profile, select a 3-Stage profile and configure Boost Voltage and Float Voltage to the same value. Click to select the appropriate battery charging profile for your batteries Create and Save Custom Battery Profiles Adjust the Current Limit of the charger output. Choose between 3 Stage and 4 stage profile and set the number of battery cells The value the charger output voltage must drop below to go into the Bulk charge state. Change the profile parameters to edit custom battery profiles Not available in the DSE9450, DSE9452, DSE9462, DSE9476, DSE9479, DSE9484 11
Edit Configuration 4.3.3 OVER CURRENT ALARM Enable or disable the alarms. The relevant value below appears greyed out if the option is disabled. Type the value or click the up and down arrows to change the settings Click and drag to change the settings Over Current Alarm Trip Trip Delay Return Return Delay The alarm activates when the current drawn by the battery exceeds the Trip setting for longer than the Trip Delay duration. The alarm is deactivated when the current drawn by the battery falls below the return value setting for longer than the Return Delay duration. 4.3.4 UNDER VOLTAGE ALARM Enable or disable the alarms. The relevant value below appears greyed out if the option is disabled. Type the value or click the up and down arrows to change the settings Click and drag to change the settings Under Voltage Alarm Trip Trip Delay Return Return Delay The alarm activates when the battery voltage falls below the Trip setting for longer than the Trip Delay duration. The alarm is deactivated when the battery voltage exceeds the Return setting for longer than the Return Delay duration. 12
Edit Configuration 4.3.5 OVER VOLTAGE ALARM NOTE: DC Over Voltage Alarm configuration is not available in DSE9462. Enable or disable the alarms. The relevant value below appears greyed out if the option is disabled. Type the value or click the up and down arrows to change the settings Click and drag to change the settings Over Voltage Alarm Trip Trip Delay Return Return Delay The alarm activates when the battery voltage exceeds the Trip setting for longer than the Trip Delay duration. The alarm is deactivated when the battery voltage falls below the return setting for longer than the Return Delay time duration. 4.3.6 BATTERY DETECTION Enable or disable the alarms. The relevant value below appears greyed out if the option is disabled. Click and drag to change the settings Battery Detection Battery Detection Test The battery charger performs a battery detection test on a regular interval set by the Battery Detection Rate. The alarm activates when a battery detection test fails. 13
Edit Configuration 4.4 MAINS 4.4.1 MAINS VOLTAGE ALARMS Enable or disable the alarms. The relevant values below will appear greyed out if the option is disabled. Type the value or click the up and down arrows to change the settings Click and drag to change the settings Mains Over Voltage Alarms Trip The alarm activates when the Mains voltage exceeds the Trip setting for longer than the Trip Delay Trip Delay duration. Return The alarm is deactivated when the Mains voltage falls below the Return setting for longer Return Delay than the Return Delay duration Mains Under Voltage Alarms Trip The alarm activates when the Mains voltage falls below the Trip setting for longer than Trip Delay the Trip Delay duration. Return The alarm is deactivated when the Mains voltage exceeds the Return setting for longer Return Delay than the Return Delay duration. 14
Edit Configuration 4.5 COMMUNICATIONS RS485 Port Communications Mode Basic Slave ID Baud Rate Advanced Master Inactivity Timeout DSENet CAN Port RS485: Configures the RS485 port to be used for MODBUS communication DSENet: Configures the RS485 port to be used for DSENet communication The Modbus Slave address and RS485 baud rate. Slave ID: This is used when connecting the RS485 port to a Modbus Master device. Baud Rate: The communications link speed. Adjustable from 1200 to 115200. Master Inactivity Timeout: Modbus timer to enable the charger to detect when the Modbus Master is no longer communicating. The DSENet slave address This is used when connecting the RS485 port to a DSE module s DSENet port. Only available for DSE9473, DSE9474, DSE9479, DSE9483, DSE9484, DSE9450 & DSE9452 The CANbus source address This is used when connecting the CAN port to a CAN device. 15
Edit Configuration 4.6 CONFIGURABLE GENCOM NOTE: Configurable Gencomm pages are NOT available in DSE9470, DSE9472, DSE9480 and DSE9841. For Modbus users of the battery charger, configurable Gencomm pages are available. 16
SCADA 5 SCADA SCADA stands for Supervisory Control And Data Acquisition and is provided both as a service tool and also as a means of monitoring / controlling the module. As a service tool, the SCADA pages are to check the operation of the controller s inputs and outputs as well as checking the operating parameters. Click to open the connection to the module. If no module is connected, the SCADA opens to show the screens for the type of module currently open in the configuration. When connection is made Click to close the connection to the module The Module s firmware revision number The SCADA page is subdivided into smaller sections. Select the required section with the mouse. 17
SCADA 5.1 ALARMS Shows any present alarm conditions. 18
SCADA 5.2 INSTRUMENTATION Shows the chargers instrumentation parameters. 19
SCADA 5.3 MODULE Shows the chargers software versions and identity information. 20
This page is intentionally blank 21
This page is intentionally blank 22