3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Similar documents
Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

OLC(T) 100 FIXED GAS DETECTOR

3M Oldham OLCT 100. Description. Fixed Gas Detector

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Transmitters/Sensors. OLCT Series

GAS DETECTOR ST400EC PART.NO

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Sieger Apex. Flexibility that meets your requirements

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

SIL 2. Ultima X Series Gas Monitors CERTIFIED

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Monitores Personales. Personal Monitor

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

SP-220. Features. Combustible handheld gas leakage detector

ALTAIR 5X Multigas Detector Product Specification

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

Global Gas Detection and Monitoring Solutions

Toxic Gas Detection. Model F12. Toxic Gas Detection

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Zareba Sensepoint Pro

ESD500. ESD500 Combustible / Toxic Gas Detector

Frequently Asked Questions

ESD3000 ESD200 Combustible / Toxic Gas Detector

Micro III (Models G203, G203S, and G213) Operation Manual

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Model D12. Digital Gas Transmitter

MICRO III (G202 / G202s / G212) Single Gas Detector

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

User manual CTX 300 Analogic Gas Detector

Operation and Maintenance Manual

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

User manual CTX 300. Analogic Gas Detector. The Fixed Gas Detection Experts. Part Number: NP300GB Revision: K.1

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

Fixed Gas & Flame Detection International Product Range Overview

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Dräger Polytron 8000 Stationary gas detector (EC)

MERIDIAN UNIVERSAL GAS DETECTOR

Dräger PIR 3000 Detection of flammable gases and vapours

Warranty Registration

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

MSA XCell Sensors. Because every life has a purpose

ULTIMA X5000. MSAX5000.com

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : E

Dräger X-am 5000 Multi-Gas Detection

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

APPLICATION DATA SHEET

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

incontrol Systems Inc. Flame and Gas Detection

Micro IV Operation Manual

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

M2A Transmitter Operator s Manual

300 SERIES. Ref.: NP300 GB Revision G

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens

S5000 Gas Monitor. GMS5000.com

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Dräger PEX 3000 Flammable Gas Detection

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : G.

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

GMA 36 Pro. Operation Manual. Stand Alone Monitor

Dräger Polytron 8720 IR Detection of carbon dioxide

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

ALTAIR 5X Multigas Detector

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Transcription:

Fixed Gas Monitoring Solutions Detection of explosive gases, toxic gases and oxygen Infrared XP IR version SIL 2 high reliability IP 66 E n o r t c e l i c 3years W a r r a t n y Certifications: The Fixed Gas Detection People

The OLC/OLCT CT range of fixed ddetectors t has been designed for detection of explosive gases, toxic gases or oxygen. According to your application, Oldham proposes you OLCT transmitter with 4-20 ma output OLC detector with a Wheatstone bridge output for detection of explosive gases. Available in explosion-proof or intrinsically safe versions, the OLC(T) is suitable for detection of all gases in ATEX zone. APPLICATIONS: Steel mills Petrochemical facilities Chemical industry Pharmaceutical industr Food industry Refrigeration industry Water treatment... IR SENSOR The infrared sensor is proposed for detection of explosive gases in more severe environmental conditions, where the presence of poisons could harm the use of a catalytic cell. With a 3-year warranty, this sensor will offer you reliability and longer life time A high temperature sensor is now available for detection of explosive gases up to 200 C.

OLCT XP Explosion-proof version is equipped with a catalytic, electrochemical or semiconductor sensor, for detection of explosive, toxic gases or oxygen. OLCT IS Intrinsically safe version is equipped with an electrochemical sensor for detection of toxic gases or oxygen. OLCT XP IR Explosion-proof version is equipped with an infrared sensor for detection of explosive gases or CO 2. OLCT XP HT High temperature explosion-proof version for detection of explosive gases up to 200 C. GAS HAZARD CO 2 Explosives Toxic or O 2 OLCT XP IR OLC OLCT XP IR OLCT XP HT OLCT XP OLCT XP OLCT IS RELIABILITY The OLC(T) is SIL 2 certifi ed by INERIS, according to EN 50402 standard, which corresponds to IEC/EN 61508 for gas detectors. The OLC(T) is a highly reliable solution for your SIL2 application. The OLDHAM, patented infrared version, allows you to reduce your maintenance intervals at an annual calibration with the same level of safety, higher than other technologies. With a probability of failure on demand of 0.13 10-6 (corresponding to a failure rate of 1 out of 2857 solicitations), the SIL 3 level of reliability would have been reached, if it was recognized by EN 50402 standard, which just considers SIL 1 and SIL 2 levels ( " SIL 3 and SIL 4 are not possible with the current technology SIL 3 gas detection systems can be achieved using 2 identical detectors "). Gas Mesure SIL Capability λ DU Reduction Risk Factor Test Period Combustibles Catalytic (C0) SIL 2 2.19 10-6 418 3 Combustibles, CO 2 Infrared SIL 2 0.13 10-6 2857 12 O 2 Electrochemical SIL 2 0.74 10-6 1234 3 CO Electrochemical SIL 2 1.09 10-6 840 3 H 2S Electrochemical SIL 2 2.98 10-6 306 3 NH 3 Electrochemical SIL 2 4.48 10-6 203 3

SENSORS TECHNICAL SPECIFICATIONS Gas Measuring Range (ppm) Version Version Range Accuracy (ppm) XP IS Temperature %RH Life Time Response ( C) (month) Time T 50/T 90 (s) Storage Condition AsH 3 Arsine 1.00-20 to +40 20-90 +/- 0.05 18 30/120 (a) Cl 2 Chlorine 10.0-20 to +40 10-90 +/- 0.4 24 10/60 (a) ClO 2 Chlorine dioxide 3.00-20 to +40 10-90 +/- 0.3 24 20/120 (a) CO Carbon monoxide 300 0-20 to +50 15-90 +/- 3 (range 0-) 40 15/40 (a) COCl 2 Phosgene 1.00-20 to +40 15-90 +/- 0.05 12 60/180 (b) ETO Ethylene oxide 30.0-20 to +50 15-90 +/- 1 36 50/240 (a) H 2 Hydrogen 2000-20 to +50 15-90 +/- 5% 24 30/50 (a) H 2S Hydrogen sulfide 30.0 0-40 to +50 15-90 +/- 1.5 (range 0-30) 36 15/30 (a) HCl Hydrochloric acide 30.0 / -20 to +40 15-95 +/- 0.4 (range 0-10) 24 30/150 (a) NH 3 NO NO 2 Ammonia Nitrogen monoxide Nitrogen dioxide 0 5000 300 0 10.0 30.0-20 to +40 15-90 +/- 5 +/- 20 +/- 150 or 10% 24 25/70 20/60 60/180-20 to +50 15-90 +/ 2 (range 0-) 36 10/30 (a) -20 to +50 15-90 +/- 0.8 24 30/60 (a) O 2 Oxygen 0-30% vol 0.4% Vol -20 to +50 15-90 (from 15 to 22% O 2) 28 6-15 (a) PH 3 Phosphine 1.00-20 to +40 20-90 +/- 0.05 18 30/120 (a) SiH 4 Silane 50.0-20 to +40 20-95 +/- 1 18 25/120 (a) SO 2 Sulphur dioxide 10.0 30.0-20 to +50 15-90 +/- 0.7 (range 0-10) 36 15/45 (a) CH 3Cl Methyl Chlorure 500-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) CH 2Cl 2 Methylene Chlorure 500-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R12 1% vol -20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R22 2000-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R123 2000-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) FX56 2000-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R134 a 2000-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R142 b 2000-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R11 1% vol -20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R23 1% vol -20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R141 b 2000-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R143 a 2000-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R404 a 2000-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R507 2000-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R410 a 0-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R32 0-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R227 1% vol -20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R407 c 0-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Freon R408 a 0-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Ethanol 500-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Toluene 500-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Isopropanol 500-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) 2-butanone (MEK) 500-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) Xylene 500-20 to +60 20-95 +/- 5 ppm to ppm 40 25/50 (c) (a) (a) + 4 C to 20 C 20 % to 60 % RH (b) +4 C to 20 C 20 % to 60 % RH maximum 3 (c) -20 C to 50 C 20 % to 60 % RH

TECHNICAL SPECIFICATIONS Model OLC OLCT XP OLCT XP IR OLCT XP OLCT XP HT OLCT XP OLCT IS Sensor Catalytic bead Catalytic bead Infrared Electrochemical Catalytic bead Semi-conductor Electrochemical Material Epoxy-coated aluminium housing (Inox 316L optional). 316 stainless steel sensors Dimensions (mm) 138x133x84 138x133x84 179x138x84 179x138x84 150x138x84 179x138x84 179x138x84 Weight (kg) 0.95 1 1.1 1.1 1.8 1.1 1.1 Ingress Protection IP66 Cable Entry M20 or ¾ NPT Supply Voltage only by OLDHAM 15.5 to 32 VDC 13.5 to 32 VDC 10 to 32 VDC 15.5 to 32 VDC 15.5 to 32 VDC 15.5 to 32 VDC Controller Average 340 ma 110 ma 60 ma 23.5 ma ma ma 23.5 ma Consumption Relative Humidity 0 % to 95 % RH 0 to 95 % RH 0 to 95 % RH Depends on gas 0 to 95 % RH 20 to 95 % RH Depends on gas (non condensing) Pressure atmospheric ± 10% Response Time T 50 = 6 s T 90 = 15 s for methane T 50 = 6 s T 90 = 15 s for methane - CO 2 version : T 50 = 11 s T 90 = 30 s - LEL version: T 50 = 11 s T 90 = 30 s Depends on gas T 50 = 6 s T 90 = 15 s for methane Depends on gas Depends on gas Average Life Time 36 to 48 36 to 48 > 48 Depends on gas 36 to 48 36 to 48 Depends on gas Continuous -40 C to +70 C -40 C to +70 C -25 C to +55 C Depends on gas -20 C to +200 C -20 C to +60 C Depends on gas Temperature Range Storage Conditions -50 C to 70 C Output signal Approvals Cable -50 C to +70 C +4 C to +20 C 10 to 60 % RH usual source encoded from 0 to 23 ma (not isolated) - linear 4 à 20mA output, reserved for measurement - 0 ma : electronic fault or no power supply - < 1mA : fault - 2 ma : initialization mode - > 23 ma : out of range Depends on gas -50 C to +70 C -20 C to +50 C Compliant with european directive ATEX 94/9/CE and with IECEx schedule for explosion-proof detectors. SIL 2 according to EN 50402 / EN 61508 Metrological performances according to EN 50054 and EN 50057 (61779-1 :2000 and 61779-4 :2000 harmonized standards) Electromagnetic compatibility according to EN 50270 2 active wires, Depends on gas 2 active wires,

ORDERING INFORMATION The reference is broken down as follows: OLCT-XPIR-001-1 OLCT XP IR Transmitter, 0-% LEL CH 4 Range: Type: Gas: Approval and entry of cable range: OLC OLCT OLCT HT5 OLCT HT10 OLCT HT15 XP IS XPIR codifyed from 1 to 999, includes gas and detection range 1 - ATEX and M20 cable entry 3 - ATEX and 3 / 4 NPT cable entry CSA approvals are pending. ACCESSORIES A Calibration cup (6 331 141) allows introduction of calibration gas on the sensor B Bypass adapter (6 327 910) allows measurement of samples C Splash guard system (6 329 004) protects the detector from liquid projections D Remote gas introduction head (6 327 911) allows introduction of gas without opening the detector E Removable protective filter (3 665 975) protects the sensor against projections and dust F Duct measurement kit (6 793 322) allows gas monitoring in a duct G Mounting bracket (6 322 420) allows to fix the detector to the ceiling H Protective cover (6 123 716) protects the detector against bad weather conditions or against direct sun radiations I Adapter plate (6 793 718) allows the replacement of another OLDHAM detector without re-drilling J Wall mounted collecting cone (6 331 169) Wall mounted for use with lighter than air gases K Ceiling mount collecting cone (6 331 168) Cieling mounted for use with lighter than air gases A B C G H I D E F J K AMERICAS Phone: +1-412-788-4353 Fax: +1-412-788-8353 info@indsci.com ASIA PACIFIC Phone: +65-6561-7377 Fax: +65-6561-7787 info@ap.indsci.com Test and calibration gas For your safety, test and calibrate your gas monitors regularly. EUROPE Phone: +33-3-21-60-80-80 Fax: +33-3-21-60-80-00 info@oldhamgas.com REV 0610 Ref. Litt_OLC(T)_ENG_v1