BRINE CHILLER DESCRIPTION

Similar documents
All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

MAC N-407 Air-Cooled Chiller

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

MACH N-407 Heat Pump Air-Cooled Chiller

SHUBHAM C O O L I N G S O L U T I O N S

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Concealed Ducted Split Series R-407C MBH

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Call us today! (800)

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

Refrigeration Plant Information. We Speak Hockey 365

.2 Section Waste Management and Disposal.

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

EHH SERIES DRAW THROUGH FAN COILS CFM

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

AIR COOLED PACKAGED CHILLER

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Call us today! (800)

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Call us today! (800)

Air-Cooled Global Chiller

VOLUME 2 (BOQ & Price Bid)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Leadership, Innovation, Advanced Technology Synergise Here!

Hi-Pres Cooling Products Catalogue. Product Catalogue

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

SECTION AIR COOLED WATER CHILLERS

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Ultimate energy saving technology

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

MAC-120HE-03 Air-Cooled Chiller

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Green economy with natural refrigerants

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Air-Cooled Water Chiller Air-Cooled Water Chiller with Heat Pump Option 3~30 Tons

Precise Temperature Control; Compact Footprint

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

SECTION ROTARY-SCREW WATER CHILLERS

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

R22 R407C. 60Hz. ACHDX Series. 225 to 415 Tons. Air Cooled Horizontal Rotary Screw Chillers. Products That Perform...

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

KELVIN Clim F497. Kelvin air conditioning

30GT FLOTRONIC AIR-COOLED CHILLERS

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

PACKAGED AIR COOLED Product Data Catalog

500 EX Fusion Compressor Series

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

kw COOLING kw HEATING

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

LC Series Chillers. Engineering Catalog. Air-Cooled Condenser

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

PYXIS U PYXIS U. rcgroupairconditioning

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Product Chillers A P P L I C AT I O N S

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

How to Select and Size a Chiller

Ultimate energy saving technology

Advance Release September 2009

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

30GN FLOTRONIC II AIR-COOLED CHILLERS

Water Chiller Solutions. A solution to every water cooling need.

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Hi-Pres Cooling Products Catalogue

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

water to water heat pumps

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

High Heat COP. High/Low Stage

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Specifications and Performance S2H

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw

Transcription:

BRINE CHILLER DESCRIPTION Scanair Brine chillers are engineered for demanding process fluid cooling applications and incorporate the latest in industry leading designed uncontrolled. Package with enhanced futures and hi performance refrigeration components our self contained air cooled and water cooled condensers incorporated chillers are extremely affordable. Brine chillers will maintained temperature range from - 40 C To + 30 C ± 1 C, capacity from 3000 Kcal/Hr to 150000 Kcal/Hr with different flow capacity. Specially these chillers are commonly used in bulk drug manufacturing, diary, food processing industry, beverage industry, chemical reactor jacket cooling applications etc., Scanair Brine chiller can be used special application in aquamarine industry the sea water cooled with titanium gasket heat exchanger evaporator for corrosion free life for many years of trouble free operation. We have a wide range of cooling fluid solution like ethylene glycol for chemical industry propylene glycol for food industry and also other fluid can be used directly in our exchanger. TITANIUM is the only heat exchanger material proven to be 100% fish and coral safe in saltwater systems. The Scanair is built with an oversized helical titanium coil in the heat exchanger to maximize calories transfer efficiency. The quite, internal, spring mounted hermetically sealed compressor provides years of reliable service. Their low profile and compact design allows for easy placement in tight places. These chillers are ideal and most suitable applications in industries like vacuum systems and evaporators, chemical reactor jacket cooling, dies & pigment manufacturing, electro plating, anodizing, vapour recovery system, heat exchangers, food processing, beverage, bakery, distillation process, diary, pharma industry etc., those applications need to be cooled in presided Temperature to reduce the cycle time and product quality, productivity. Scanair chillers are designed new generation styled and built esthetically to match the modern trend in equipment manufacturing.

BRINE CHILLER GENERAL SPECIFICATION COMPONENTS STANDARD SPECIFICATIONS OPTIONAL SPECIFICAT COMPRESSOR FAN MOTOR CABINET CONTROLS AND SAFETIES THERMOSTAT ELECTRICAL INDICATORS REFRIGERANT AIR COOLED CONDENSERS WATER COOLED CONDENSERS EVAPORATORS EXPANSION VALVE Hermetically sealed, sem Hermetically sealed, Scroll compressors make emers compressor with overload protection. maneurop, bitzer,frascold Propeller fan Dynamically balanced ball bearing with self mounting type. GEC, Anbo, Rockwell, Cr EBM Nadi Galvanized steel fabrication with powder coat paint finish, Colours SS Stainless Steel fabrica available Dark Blue with Lite Blue, or accommodate special siz Dark Gray with VIP Blue or Dark colours for bulk orders. Gray with lite Siemens gray. Flow controller, water leve switch, inlet temperature Hp Lp cutout, temperature controller, temperature indicator, Au compressor OLR, Pump OLR, single outgoing solenoid valve, a phase preventor. high temperature alarm, n fluid distribution header, p meter, PH Meter and add Digital thermostat with differential adjustment system. Single Phase 220V, 50 Hz, Three Phase 440 V, 50 Hz. Phase indicators, HPLP, water low level, Single phase Preventor, compressor on, pump on. R-134 A,R-22, R - 404 A Aluminum fin copper grooved pipe brazed heat exchanger. MS Shell and Copper grooved pipe heat exchanger. Fin and tube type, dipped coil, Plate type Heat Exchanger. Thermostatic expansion valve, Emersion, Danfoss. BRINE TANK Made out of Stainless Steel 304 Grade 16 Gauge thickness With NTC, PT100, RTD S Subzero temperature con USB/RS 232, RS 485, Te Record/Print/Temperature Monitoring, Remote contr Single phase 220 V, 60 H Water pressure, Antifreez high level, Water outlet te R- 410 A, R-507 A, R- 40 R 23. Copper fin, copper groove SS Shell and Copper gro PHE Brazed heat exchan SS fin and Tube type, Tub exchanger, Shell and coil Capillary tube, Thermosta external equalizer, Electro SS 316 L, PVC Tank, Cop coated, MS Tank with epo

PUMPS BRINE FLOW RATE PIPING WARRANTY NOTIFICATION: The information given above is based on our current state of knowledge due to the continuing process of product improvement all information in this brochure is subject to change without notification. Above specifications for only standard models if customer required specifications for Vertical, Horizontal Model Will be given on request form. STANDARD MODEL: Machines will have our standardized inner and outer dimension measurements. VERTICAL MODEL : Machines will occupy less floor space, measurement of height, inner and outer dimensions will vary. HORIZONTAL MODEL: Machines will occupy more floor space and height will be less than 3 ft., specially Suited for low roof buildings. fabrication. Centrifugal monoblock pump, Wilo make, Crompton Greaves, Nanfang Cast iron or Stainless steel body. Chiller will be supplied as per our recommended Flowrate specified in technical standards. Refrigerant piping is rigid copper with service valves insulated suction lines. Water circuit made out of GI threaded configrated with brided hosepipes with necessity valves, all pipes are insulated. 18 Months from the date of dispatch or 12 Months from the date of installation which our is earliest. Groundfass, Multistage v designs, Stainless steel c Piston pump, Diafrom pum Any specific flowrate requ be supplied. Drain valve, SS Pipe line, special fluids and corrosio piping, seamless polymer Torcellin. 3 Years warranty on comp labour.

BRINE CHILLER TECHNICAL CONFIGURATION CAPACITY RANGE UNIT TYPE TEMPERATURE 0.5 TR 100 TR and above. Independent function or group function. -30 C TO + 30 C Media Temperature. COOLING CAPACITY Evaporation at 7 C, Condensation at 50 C. COOLING MEDIA EVAPORATION TYPE COMPRESSOR TYPE CONDENSORS EVAPORATOR WATER FLOW RATE WATER PUMP REFRIGERANT TYPE INSULLATION ELECTRICALS WORLDCLASS Ethylene, propylene glycol, calcium chloride, Sodium Choloride (Sea Water). Online, storage type, direct immersion type. Hermetically sealed, Scroll, Digital Scroll, semi hermetic, screw, Open type. Water or air cooled grooved pipe heat exchanger. Plate type heat exchanger, fin and tube type, shell and tube type, dipped coil, Tube in Tub Very wide range from 5 Lpm to 2000 Lpm+ Centrifugal monobloc, vertical Multi stage pump, (optional) Stainless steel pumps, Horizo R-22, R-134A, R- 404A, R-507A, R- 407C Torcellin, puf, nitral rubber, thermo cool, thermorex. 1Ph 230 V, 50 Hz, AC, 3 Ph 440 V, 50 Hz, AC, Attachable, Detachable Penal Board. Designed to meet ASHRAE, ARI and International standards.

BRINE CHILLER TECHNICAL SPECIFICATION BRINE CHILLER SAB-30S SAB-45S SAB-60S SAB-90S SAB-120S SAB-150S SAB-180S SAB-225S SAB-300S SAB-375S SAB-450S SAB-600S NOM TONS KCAL/HR 1.0 3170 1.5 4550 2.0 6000 3.0 9200 4.0 12600 5.0 15000 6.0 18750 7.5 22500 10 31000 12.5 37500 15 47000 20 61450 TANK LTRS PUMP HP FLOW POWER RATE LPM SUPPLY COMPRESSOR RLA AMPS FAN MOTORS HP 20 0.5 16 220 V 6.3 1/10 16 30 0.75 24 440 V 4 1/8 18 40 1 38 440 V 5.3 1/5 22 60 1 38 440 V 7.5 1/4 26 80 1 38 440 V 8.5 1/4 28 80 1 38 440 V 10.5 1/4X 2 30 120 1.5 56 440 V 13 1/4X2 32 120 1.5 56 440 V 13.5 1/3X2 32 150 2 128 440 V 21 1/3X4 50 200 2 128 440 V 26 1/2X2 56 200 2 128 440 V 30 1/2X2 60 200 3 246 440 V 43 1/2X2 60 O D W SAB-750S 25 200 3 246 440 V 51 1/2X4 72

SAB-900S SAB-1200S SAB-1500S 75300 30 92500 40 126800 50 154500 300 5 465 440 V 58 1/2X4 72 400 5 465 440 V 76 1X2 72 500 5 465 440 V 92 1X4 84