High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
|
|
- Walter Morton
- 5 years ago
- Views:
Transcription
1 High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw kw) ISO 9001 : 2008 ISO : 2004 ISO : 2007
2 R - 410a 50Hz Introduction: Established in the year 2004, we specialize in manufacturing of central air-conditioning and kitchen ventilation equipment, with a full-fledged manufacturing facility in Dubai Investments Park (DIP). We provide quality HVAC solutions for residential, commercial & specialized applications. Our vast experience and engineering skills allows us to offer true value added benefits to our clients. TROSTEN I Ducted Split Air Conditioners
3 Introduction Nomenclature Salient Features Product Specifications System Performance Data Fan Performance Data Electrical Data Recommended Pipe Selection Dimensional Drawings Wiring Diagrams Guide Specification ESMA certified split indoor and outdoor series by Trosten provides not only the ultimate comfort, but also long and trouble free operations. These products are registered under the Emirates Conformity Assessment Scheme (ECAS) based on compliance to the following requirements. UAE.S :2014 Labeling Energy Efficiency label for electrical appliances Part 5: Commercial and Central Air Conditioners. ECAS specific requirements for registration of low voltage equipment.
4 Nomenclature Outdoor Unit 6: V/1Ph/50Hz 1: R-410 a 7: R-407 c Indoor Unit 6: V/1Ph/50Hz 1: R-410 a 7: R-407 c
5 Indoor Salient Features The concealed ductable split units are of compact and energy efficient design, delivering ultimate performance. The units provide solutions for most of the domestic and commercial applications, designed with the optimum comfort, installation time-savings and reduced running costs for the end-user. The concealed ductable indoor units are designed using the latest fan coil technology, highly efficient in performance and ideal for whisper quiet operation. The indoor air compartment is completely insulated with fire retardant polyethylene insulation. Units are designed with advanced refrigerant circuiting offering minimal pressure drop for ideal performance. The units are made out of high quality galvanized steel for reliability and durability. The concealed ductable indoor units are available with the electrical characteristics of volts, 1 phase, 50 hz operation. The control voltage is 220 volts. Factory assembled controls with 220 volts wired remote controller (wireless remote controller is optional). Units are completely factory wired with single point power input, provided with knockouts for utility, main power supply and control connections. The evaporator coils are made out of seamless, inner grooved copper tube / corrugated aluminum fins. Efficient and dependable metering of the refrigerant is provided by thermostatic expansion device or flow restrictor, a device which improves overall system reliability and is easily accessible for routine maintenance. 03
6 Salient Features Outdoor The outdoor condensing units of TAC series are suitable for side and top discharge installation on the roof or on the ground. Units have been incorporated with high efficiency rotary / scroll compressor in single stage operation for improved comfort, performance and reliability. Units are designed & tested in accordance with AHRI standards. The outdoor condensing units are available with the electrical characteristics of volts, 1 phase, 50 Hz operation up to 11 kw nominal cooling capacity and thereafter by volts, 3 phase, 50 Hz operation. Compressors are fully hermetic rotary or scroll type designed for high efficiency and provided with standard controls & safety devices. Higher capacity compressors are provided with crankcase heaters to warm oil and prevent dilution by refrigerant. HP and LP controls for models above 11 kw are provided for the safe operation of the compressor. Units are provided with easy accessible control box, compressor and High pressure switch. Condenser fans are propeller type, direct driven, draw through side / vertical discharge with fan guard mounted to the panel. The fan design provides an efficient airflow rate while operating at low rotational speeds to reduce fan noise. The design incorporates robust characteristics that provide good performance over a range of static pressure. Condenser coils are made of seamless, inner grooved copper tube and aluminum corrugated fins, mechanically bonded for maximum heat transfer TAC units have significant performance advantages in terms of efficiency, noise performance and power consumption. The condenser coils are factory tested for leaks and pressure tested at 600 psig. The outdoor units are leak tested with electronic machines and fully charged with refrigerant R410a. The outdoor units are made out of high quality galvanized steel, powder coated for long lasting protection and durability. 04
7 Product Specification T1 T3 Outdoor Unit Indoor Unit Model Cooling Capacity Power Input EER Cooling Capacity Power Input EER Fan Type Air Flow Rate Coil Fan Coil Fan Compressor External Static Pressure Power Input Fan Motor Protection Material Tube Diameter Material Fin No.of Rows Condensate Drain Size Air Filter System Operation Control Unit Dimension H x W x D Weight Power Supply Air Discharge Compressor Type Quantity Vibration Isolator Protective Device Fan Type / Drive Quantity Fan Speed Blade Material Tube Construction Tube Material Fin No.of Rows Unit Dimension Weight Pipe Size Refrigerant Power Supply Indoor Unit TDF-G06S1N6 TDF-G08S1N6 TDF-G10S1N6 TDF-G12S1N6 Outdoor Unit TAC-G18D1N6 TAC-G24D1N6 TAC-G30D1N6 TAC-G36D1N6 Btu/hr 17,300 21,600 25,600 34,890 W 1,650 2,070 2,560 3,210 Btu/hr / W Btu/hr 15,400 18,800 22,400 29,800 W 1,890 2,310 2,750 3,670 Btu/hr / W Double Inlet Double Width CFM ,200 Inches wg W Auto Reset Thermal Overload Inner Grooved Copper Tube Inches 5/16" 5/16" 3/8" 3/8" Aluminum Inches 3/4" Synthetic, Washable Wired Controller With Remote mm 245 x 1025 x x 1025 x x 1255 x x 1100 x 660 kg V / Ph / Hz Type / 1 / 50 Side Rotary Scroll No Rubber Mount Auto Reset Thermal Overload Propeller / Direct Drive No RPM ABS Fin Tube Construction Inner Grooved Copper Tube Aluminum H x W x D mm 650 x 870 x x 870 x x 925 x x 925 x 395 kg Suction 1/2" 5/8" 5/8" 5/8" Inches Liquid 1/4" 1/4" 3/8" 3/8" Type R-410a No. of Circuits V / Ph / Hz / 1 / 50 Notes: T1 Condition: Rated at F DB, F WB & 95 0 F ambient temperature. T3 Condition: Rated at F DB, F WB & F ambient temperature. Specifications are subject to change without notice in accordance with our policy of continous research and product development. 05
8 Product Specification T1 T3 Outdoor Unit Indoor Unit Model Cooling Capacity Power Input EER Cooling Capacity Power Input EER Fan Type Air Flow Rate Coil Fan Coil Fan Compressor External Static Pressure Power Input Fan Motor Protection Material Tube Diameter Material Fin No.of Rows Indoor Unit TDF-G14S1N6 TDF-G16S1N6 TDF-G20S1N6 Outdoor Unit TAC-G42D1N5 TAC-G48D1N5 TAC-G60D1N5 Btu/hr 39,000 46,640 51,600 W 3,750 4,370 4,860 Btu/hr / W Btu/hr 34,000 38,800 43,700 W 4,190 4,780 5,340 Btu/hr / W Double Inlet Double Width CFM 1,382 1,600 1,800 Inches wg W Auto Reset Thermal Overload Inner Grooved Copper Tube Inches 3/8" 3/8" 3/8" Aluminum Condensate Drain Size Inches 3/4" Air Filter Synthetic, Washable System Operation Control Wired Controller with Remote Unit Dimension H x W x D mm 378 x 1100 x x 1100 x x 1200 x 700 Weight kg Power Supply V / Ph / Hz / 1 / 50 Air Discharge Type Side Top Compressor Type Scroll Quantity No Vibration Isolator Rubber Mount Protective Device Auto Reset Thermal Overload Fan Type / Drive Propeller / Direct Drive Quantity No Fan Speed RPM 900 1,050 1,050 Blade Material ABS Metal Tube Construction Fin Tube Construction Material Tube Inner Grooved Copper Tube Fin Aluminum No.of Rows Unit Dimension H x W x D mm 1150 x 925 x x 765 x x 765 x 765 Weight kg Pipe Size Refrigerant Suction 3/4" 3/4" 3/4" Inches Liquid 3/8" 3/8" 1/2" Type R-410a No. of Circuits Power Supply V / Ph / Hz / 3 / Notes: T1 Condition: Rated at F DB, F WB & 95 0 F ambient temperature. T3 Condition: Rated at F DB, F WB & F ambient temperature. Specifications are subject to change without notice in accordance with our policy of continous research and product development.
9 System Performance Data Indoor TDF - G06S1N6 R - 410a / 50 Hz Outdoor TAC - G18D1N6 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 231 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 212 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 189 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 07
10 System Performance Data Indoor TDF - G06S1N6 R - 410a / 50 Hz Outdoor TAC - G18D1N6 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 210 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 193 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 172 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 08
11 System Performance Data Indoor TDF - G08S1N6 R - 410a / 50 Hz Outdoor TAC - G24D1N6 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 349 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 321 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 283 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 09
12 System Performance Data Indoor TDF - G08S1N6 R - 410a / 50 Hz Outdoor TAC - G24D1N6 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 317 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 292 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 258 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 10
13 System Performance Data Indoor TDF-G10S1N6 R - 410a / 50 Hz Outdoor TAC-G30D1N6 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 402 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 368 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 323 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 11
14 System Performance Data Indoor TDF-G10S1N6 R - 410a / 50 Hz Outdoor TAC-G30D1N6 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 365 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 335 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 294 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 12
15 System Performance Data Indoor TDF-G12S1N6 R - 410a / 50 Hz Outdoor TAC-G36D1N6 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 589 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 540 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 476 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 13
16 System Performance Data Indoor TDF-G12S1N6 R - 410a / 50 Hz Outdoor TAC-G36D1N6 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 567 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 519 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 458 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 14
17 System Performance Data Indoor TDF-G14S1N6 R - 410a / 50 Hz Outdoor TAC-G42D1N5 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 683 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 653 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 632 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 15
18 System Performance Data Indoor TDF-G14S1N6 R - 410a / 50 Hz Outdoor TAC-G42D1N5 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 653 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 623 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 602 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 16
19 System Performance Data Indoor TDF-G16S1N6 R - 410a / 50 Hz Outdoor TAC-G48D1N5 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 789 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 756 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 732 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 17
20 System Performance Data Indoor TDF-G16S1N6 R - 410a / 50 Hz Outdoor TAC-G48D1N5 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 755 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 722 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 698 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 18
21 System Performance Data Indoor TDF-G20S1N6 R - 410a / 50 Hz Outdoor TAC-G60D1N5 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 882 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 854 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 830 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 19
22 System Performance Data Indoor TDF-G20S1N6 R - 410a / 50 Hz Outdoor TAC-G60D1N5 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) T S T S T S T S MBH kw / 849 (High) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 821 (Medium) PI kw MBH kw PI kw MBH kw PI kw MBH kw / 797 (Low) PI kw MBH kw PI kw MBH kw PI kw Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 20
23 Fan Performance Data Imperial Fan Speed ESP Inches wg Airflow Rate (CFM) Indoor Model TDF Series: G06S1N6 G08S1N6 G10S1N6 G12S1N6 G14S1N6 G16S1N6 G20S1N6 0" " High 0.2" " " " " Medium 0.2" " " " " Low 0.2" " " Metric Fan Speed ESP Pascals (Pa) Airflow Rate (LPS) Indoor Model TDF Series: G06S1N6 G08S1N6 G10S1N6 G12S1N6 G14S1N6 G16S1N6 G20S1N High Medium Low ESP CFM LPS - External Static Pressure - Cubic Feet per Minute - Litres per Second 21
24 Electrical Data Electrical Data For Indoor Units Indoor Model TDF Series: V / Ph / Hz G06S1N6 G08S1N6 G10S1N6 G12S1N6 G14S1N6 G16S1N6 G20S1N / 1 / 50 Operating Voltage Blower Motor Min Max HP FLA MCA Amps MOCP Amps Electrical Data For Outdoor Units Outdoor Model TAC Series: V / Ph / Hz G18D1N6 G24D1N6 G30D1N6 G36D1N6 G42D1N5 G48D1N5 G60D1N / 1 / / 3 / 50 Operating Voltage Min Max RLA Compressor LRA Quantity HP Condenser FLA Quantity MCA Amps MOCP Amps Notes: FLA LRA RLA MCA MOCP - Full Load Amps - Locked Rotor Amps - Running Load Amps - Minimum Circuit Amps - Maximum Over Current Protection 22
25 Recommended Pipe Selection Liquid Line Pipe Selection (Outdoor unit above indoor unit) Equivalent Pipe Length (feet) (Vertical + Horizontal) TDF-G06S TDF-G08S TDF-G10S TDF-G12S TDF-G14S TDF-G16S TDF-G20S TAC-G18D TAC-G24D TAC-G30D TAC-G36D TAC-G42D TAC-G48D TAC-G60D Pipe Size 16' 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 25' 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 33' 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 50' 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 66' - - 3/8" 3/8" 3/8" 3/8" 1/2" 82' - - 3/8" 3/8" 3/8" 1/2" 1/2" 98' - - 3/8" 3/8" 3/8" 1/2" 1/2" 115' - - 3/8" 3/8" 3/8" 1/2" 1/2" 131' - - 3/8" 3/8" 3/8" 1/2" 1/2" Liquid Line Pipe Selection (Indoor unit above outdoor unit) Equivalent Pipe Length (feet) (Vertical + Horizontal) TDF-G06S TDF-G08S TDF-G10S TDF-G12S TDF-G14S TDF-G16S TDF-G20S TAC-G18D TAC-G24D TAC-G30D TAC-G36D TAC-G42D TAC-G48D TAC-G60D Pipe Size 16' 1/4" 1/4" 3/8" 3/8" 3/8" 1/2" 1/2" 25' 1/4" 1/4" 3/8" 3/8" 3/8" 1/2" 1/2" 33' 1/4" 1/4" 3/8" 3/8" 3/8" 1/2" 1/2" 50' 1/4" 1/4" 3/8" 3/8" 3/8" 1/2" 1/2" 66' 1/4" 1/4" 3/8" 3/8" 3/8" 1/2" 1/2" 82' 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 98' 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 115' 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 131' 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" General Notes: a. Standard pipe size supplied by factory will be 16' (5m) b. Total equivalent length of piping should be limited to 131' (40 m) c. For rotary compressor the total equivalent length of piping is to be limited to 50' (15 m) d. For scroll compressor the total equivalent length of piping is to be limited to 131' (40 m) e. Additional Refrigerant Charge Liquid Line Size R410a Charge (grams / ft) 1/4" 10 3/8" 17 1/2" 24 23
26 Recommended Pipe Selection Suction Line Pipe selection Equivalent Pipe Length (feet) (Vertical + Horizontal) TDF-G06S TDF-G08S TDF-G10S TDF-G12S TDF-G14S TDF-G16S TDF-G20S TAC-G18D TAC-G24D TAC-G30D TAC-G36D TAC-G42D TAC-G48D TAC-G60D Pipe Size 16' 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 25' 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 33' 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 50' 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 66' - - 5/8" 5/8" 3/4" 3/4" 7/8" 82' - - 5/8" 5/8" 3/4" 3/4" 7/8" 98' - - 5/8" 5/8" 3/4" 7/8" 7/8" 115' - - 3/4" 3/4" 3/4" 7/8" 7/8" 131' - - 3/4" 3/4" 7/8" 7/8" 7/8" Capacity Loss Multiplier Equivalent Pipe Length (feet) (Vertical + Horizontal) TDF-G06S TDF-G08S TDF-G10S TDF-G12S TDF-G14S TDF-G16S TDF-G20S TAC-G18D TAC-G24D TAC-G30D TAC-G36D TAC-G42D TAC-G48D TAC-G60D 16' ' ' ' ' ' ' ' ' General Notes: a. Standard pipe size supplied by factory will be 16' (5m) b. For rotary compressor the total Equivalent length of piping is to be limited to 15 meters c. For Scroll compressor the total Equivalent length of piping is to be limited to 40 meters d. When the Outdoor unit is located above indoor unit, install a suction riser every 5 meters e. The capacity derating as per the performance chart applicable at various ambient temperatures f. The total length exceed more than 20 mts the following components to be installed at site g. Hard start kit (start capacitor and relay) must be installed on outdoor unit for single phase condensers h. Crankcase heater must be installed on compressors 24
27 Dimensional Drawings 25
28 26 Dimensional Drawings
29 Dimensional Drawings 27
30 28 Dimensional Drawings
31 Indoor Units Wiring Diagrams 29
32 Wiring Diagrams Outdoor Units 30
33 Outdoor Units Wiring Diagrams 31
34 Wiring Diagrams Outdoor Units 32
35 Outdoor Units Wiring Diagrams 33
36 Guide Specification General: Ducted Split Units shall be of high efficiency performance, being suitable for side and up flow installation on the roof or on the ground. Units shall be highly competent in performance and ideal for both commercial and residential application with whisper quiet operation. Units shall be designed to work up to 52 C (125.6 F) without tripping. Outdoor Unit: Outdoor units shall be designed and tested, conforming to AHRI Standards. Units shall be leak tested with electronic machines, piped, internally wired and fully charged with refrigerant R410a. Units shall be made from high quality, corrosion resistant galvanized steel casing and shall be powder coated for weather resistance and resilience. The galvanized steel sheets shall conform to ASTM-A525 and the powder coated panels shall be able to withstand 1000 hours as per ASTM-B117. Compressors shall be highly efficient rotary / fully hermetic scroll with standard controls and safety devices. Higher capacity compressors shall be provided with crankcase heaters which warm oil and keeps in check attenuation by refrigerant. High pressure and low pressure controls shall be provided for units above 36,000 Btu/hr. Internal thermal overload protection shall be available with the compressor. Condenser coils shall be constructed out of seamless inner grooved copper tube and aluminum corrugated fins mechanically bonded for maximum heat transfer. Coils shall be designed to have minimum pressure drop for refrigerant flow to induce the best output. Coils shall be factory pressure tested at 600 PSI. Condenser fans shall be propeller type, direct drive draw through vertical discharge with fan guard mounted to the panel. The outdoor units shall operate in electrical characteristics of Volts / 50 Hz / 1Ø upto 36,000 Btu/hr and Volts / 50Hz / 3Ø for capacities from 42,000 Btu/hr and above. 34
37 Guide Specification Indoor Unit: Indoor units shall comprise of evaporator coil, fan motor assembly, synthetic washable filter and metering device. Units shall have a compact design and a low profile suitable for horizontal Installation in most standard drop ceiling application thus providing flexibility in installation. The fans shall operate at three different speeds of Low, Medium and High. Fan type shall be double inlet double width (DIDW) and of ABS material. The motor provided shall be a single phase unit suitable for Volts / 50 Hz. Unit shall be provided with factory assembled controls with a Volts wired remote controller. Fan motor shall be internally thermal protected. Evaporator coil shall be constructed of seamless inner grooved copper tube and corrugated aluminum fins for high efficiency and durability. Units shall be constructed with an advanced refrigerant circuitry, offering minimum pressure drop and delivering the best possible output. The metering device shall be a flowrator / thermostatic expansion valve (TXV) Low density insulation provided in the units shall habilitate a quiet performance. The air compartment in the indoor unit shall be completely insulated with closed cell elastomeric insulation. All units shall be completely factory wired with single point power input provided with knockouts for utility, main power supply and control connections. The units shall be leak tested at 600 PSI by electronic machines, piped, internally wired and shall have a holding charge of refrigerant R410a. 35
38 Notes
39 Notes
40 Ref:TR/CAT/DSAC/16/02
FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationConcealed Ducted Split Series R-407C MBH
Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY
More informationDUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES
DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More informationDUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C
DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationPAJ3. Product Specifications
13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationUP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT
SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A
More informationMAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationMAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate
More informationSELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS
SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationProduct Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons
0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationTECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely
More informationProduct Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons
007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),
More informationPACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationMidea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual
Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without
More informationUP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM
EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More informationPAR5. Product Specifications
TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced
More informationJOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:
T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED
More informationWJH4 Product Specifications
UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More informationWCH5**4. Product Specifications
HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY
More informationGeneral Description. Operation
ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationAll side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.
All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing
More informationProduct Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons
(60Hz) Single-Package Air Conditioners 3-5 Nominal Tons Product Data The is a package air conditioner for manufactured housing, residential, and light commercial applications. The unit design is the result
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More information16 SEER TWO-STAGE AIR CONDITIONERS
FORM NO. ATZ-210 Supersedes Form No. ATZ-210 16 SEER TWO-STAGE AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability
More information48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS
48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION
More informationPC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]
PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed
More informationWall Mounted Split Systems
MWM - 2005 Wall Mounted Split Systems Models: MWM 007F/FR MWM 010F/FR MWM 015F/FR MWM 020F/FR MWM 025F/FR MWM 030F/FR Contents Features... 1 Nomenclature... 2 Specifications... 3 Performance Table... 11
More informationAdvance Release September 2009
Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationProduct Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons
50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons Product Data The 50EES unit with ZP technology is a package air conditioner for manufactured housing, residential, and light commercial
More informationR4H4. Product Specifications
R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on
More informationN4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationProduct Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion
38ARZ/ARD Commercial Air-Cooled Split Sizes 007-028 With 40RM007-028 6-25 Nominal Tons - 50Hz Product Data The 38ARZ/ARD condensing units with scroll compressors match Carrier s 40RM indoor-air handlers
More informationFLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13
Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationCondensing Units CUS 15-60
Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:
GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationCFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH
CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More informationCFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH
CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More information50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant
Package Rooftop Units Quality Assurance Certificate Reg. No: 04 100 950420 Subject to change without notice Manufacturing point: Jeddah, Saudi Arabia Nearest port of embarkation: Jeddah Islamic port Product
More informationCFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH
CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More informationProduct Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )
Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,
More informationTechnical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationProduct Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )
SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured
More informationWall Mounted Air Conditioners with Gas Heat Models AVGA
PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety
More informationVERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons
491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED
More informationProduct Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )
PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit PA3Z- B A10165 The PA3Z- B unit is a packaged air conditioner
More informationNH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT
ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230
More informationProduct Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving
Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE
More informationTABLE OF CONTENTS INTRODUCTION NOMENCLATURE AC P S J 035 C CO AR Q - 2 -
TABLE OF CONTENTS Page No Introduction... 2 Nomenclature... 2 Components... 3 Standard Features... 3 Optional Accessories... 5 Cooling and Heating Portfolio... 5 Physical Specifications... 6 System Cooling
More informationCATALOG. SKYPAK Self-Contained Heating/Cooling Units
CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationContent. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...
R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor
More informationSUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationYour Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED
Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5
More informationWALL-MOUNT HEAT PUMPS - (60HZ)
WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling
More informationRuud Commercial Achiever Series Package Gas Electric Unit
Package Gas Electric Ruud Commercial Achiever Series Package Gas Electric Unit RKPN- 14 SEER Series RKQN- 15 SEER Series Nominal Sizes 3-5 Tons [10.6-17.6 kw] (15 SEER/12.0 EER AND ABOVE ONLY) Proper sizing
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel
More information13 GEP A L P - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800
More informationN4H4. Product Specifications
14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors
More informationGREEN REFRIGERANT R-410A
WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to,000 Capacities:,00 to,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More information15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING
SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant
More informationSUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More information13 SEER CONDENSING UNITS
FORM NO. A11-182 REV. 8 Supersedes Form No. A11-182 Rev. 7 13 SEER CONDENSING UNITS Features Painted louvered steel cabinet. Easily accessible control box. Condenser coils constructed with copper tubing
More information60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES
60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,
More informationProduct Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationTHE WALL-MOUNT TM SIX TON AIR CONDITIONER
The Bard Wall-Mount Six Ton Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or
More informationRetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)
Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt,
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationDRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION
CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner
More informationAdvance Product Data
Infinityr 19VS Variable Speed Air Conditioner 2, 3, and 4---Ton (5---Ton Coming Q4 2014) Advance Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationProduct Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons
Product Data 50ZP Single-Package Air Conditioners 2 to 5 Tons UNIT 50ZP The 50ZP unit is a packaged air conditioner for manufactured housing, residential, and light commercial applications. The 50ZP unit
More informationProduct Data INDUSTRY LEADING FEATURES / BENEFITS. 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48
38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48 Product Data INDUSTRY LEADING FEATURES / BENEFITS A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT. The 38MBQ series ductless
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More information