PACKAGED REFRIGERATION CONDENSING UNITS

Similar documents
PACKAGED REFRIGERATION CONDENSING UNITS

500 EX Fusion Compressor Series

ENTHALPY TD SERIES CONDENSING UNITS. Enthalpy. Semi Hermetic TD Series Condensing Units (Medium / Low Temperature)

ENTHALPY TD SERIES CONDENSING UNITS

MULTIPLE COMPRESSOR SYSTEMS COMPRESSOR PACKAGES ORIGINAL MANUFACTURED EQUIPMENT. Multiple Compressor Systems BA AUS

Gear up for summer Familiarise yourself with our indoor condensing unit range Page 9-11 THE GAUGE ISSUE 10

Kirby Commander Condensing Unit

AIR COOLED CONDENSING UNIT

ENTHALPY HERMETIC CONDENSING UNITS

Call us today! (800)

Air-Cooled Condensing Units with Compact Screw Compressors

Call us today! (800)

Call us today! (800)

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

AMERICAN STANDARD 14 MODELS 4A7B E

The results are in! THE GAUGE ISSUE 11. DC-3 Field Trial - Case Study Results Page 4-5. Outdoor Condensing Units Comparing the Range Page 8-9

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

Split System Cooling Product Data

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

Split System Heat Pump Product Data

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Split System Heat Pump Product Data

Technical Bulletin (TB )

Split System Cooling Product Data

commercial refrigeration products

Split System Heat Pump Product Data

SUBCRITICAL & TRANSCRITICAL SYSTEMS

Split System Cooling Product & Performance Data

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

ROOFTOP PACKAGED AIR CONDITIONERS

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

NATURAL REFRIGERANT SYSTEMS

30GN FLOTRONIC II AIR-COOLED CHILLERS

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

CALOREX TECHNICAL GUIDE PRO-PAC H HY. Air/water heat pumps

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

MACH N-407 Heat Pump Air-Cooled Chiller

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Split System Cooling Product Data

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

Split System Cooling Product Data

Air-Cooled Condensing Units with Bitzer Compressors

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Commercial and Technical Data

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Split System Heat Pump Product & Performance Data

MAC N-407 Air-Cooled Chiller

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SMALL AIR COOLED CONDENSERS

Split System Cooling Product Data

Split System Heat Pump Product Data

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

30GT FLOTRONIC AIR-COOLED CHILLERS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Kramersaver Air Cooled Condensing Units

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Condensing Units CUS 15-60

Remote Air Cooled Condensers C2 Series

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Technical Bulletin (TB-0037)

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

OACS Outdoor Air-Cooled Central Chillers

Split System Cooling Product Data

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Water Chiller Solutions. A solution to every water cooling need.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Copeland Scroll. Product Information. Outdoor condensing units for refrigeration applications

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

EN aquatech.piovan.com

AIR COOLED CONDENSERS

Technical guide Pro-Pac H HY. Air/water heat pumps

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Split System Cooling Product Data

.2 Section Waste Management and Disposal.

Super-Flo Low Profile Unit Cooler

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

Copeland Scroll Outdoor Refrigeration Unit

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Commercial High-Efficiency Condensing Units

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

air systems Roomtop RTC-RTH 15 to 30 - L

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Transcription:

PACKAGED REFRIGERATION CONDENSING UNITS 1.7kW 64.2kW

Nomenclature UNDERSTANDING THE ACPAC MODELS The Acpac part numbers are based around a nomenclature system, which means there is thought behind the names, which makes it easier to decipher the model and its attributes. Please see an example below of an Acpac model number broken down. Acpac Packaged Refrigeration Condensing Units AP S 39.5 ML 2-1 Version Number of Fans Application M = Medium Temperature L = Low Temperature ML = Medium and Low Temperature Refrigeration Capacity in kw @ -5 C SST/ C Ambient on R404A Compressor Type Blank = Tecumseh hermetic S = Tecumseh semi hermetic B = Bitzer semi hermetic C = Copeland scroll AP = Acpac Packaged Refrigeration Condensing Unit 2

3

Packaged Condensing Units ACPAC PACKAGED CONDENSING UNITS OFFER A COMPLETE REFRIGERATION SOLUTION The Acpac range is designed in Australia to provide a robust energy efficient, fully fitted packaged range with world leading hermetically sealed reciprocating, scroll and semi hermetic reciprocating compressors. Acpac uses premium compressors and large condensers in combination to ensure reliable refrigeration when you need it most. This is the Acpac packaged advantage. Applications are diverse and include commercial food, beverage cooling, and freezing in supermarkets, as well as refrigeration applications in convenience stores, pubs and clubs, restaurants, cafés, food processors and many more. Installation is quick and easy as every Acpac is fully optioned straight out of the box. All Acpac units include condenser fan controls and epoxy coated condenser fins to ensure superb energy efficient performance in Australia s diverse weather conditions. Acpac packaged condensing units are a perfect solution for your customers refrigeration requirements. STANDARD FEATURES World leading compressors Large epoxy finned condenser/s Oil Separator on every model Suction Accumulator on most models Liquid Receiver Comprehensive electrical board fully wired to all electrical components Safety controls offering substantial protection Condenser fan control provides stable operation in Australia s diverse weather conditions Copper tails for easy connections Galvanized powder coated enclosures not only protect the unit but provide a good looking professional finish every time Easy to read wiring diagram is permanently attached to inside panel for quick service Separate compressor and fan compartments for safe and easy maintenance Easy access to all serviceable components 4 Acpac Packaged Refrigeration Condensing Units

Hermetic Reciprocating THE TECUMSEH HERMETIC COMPRESSOR The L Unite Hermetique compressor range from Tecumseh Europe has built an awesome reputation in the refrigeration industry due to its proven reliability and performance. The conservative design within this hermetic reciprocating range offers the end user a cost effective refrigeration solution with the benefits of energy efficiency, low noise and reliability. The Tecumseh compressors are matched with large condensers to provide an Acpac range with refrigeration capacities from 1.1 to 13.1kW using R404A refrigerant. The range is also suitable for R134a in many applications, please refer to an Actrol Applications Engineer for specific advice. The Acpac reciprocating hermetic range is commonly used for refrigerated cabinets, reach-in and walk-in coolrooms and freezers for every product imaginable including butcher shops, fish shops, fruit and vegetable stores, fast food chains, food processors and many more. ADDITIONAL FEATURES Tecumseh hermetic reciprocating compressors Compressor thermal overload protection on all three phase models Suction accumulator on all low temperature models Sump heater on all models Condenser fan HP cycling maintains the condensing temperature in all ambient conditions 5

Semi Hermetic Reciprocating The SH semi hermetic compressor from Tecumseh has a proven reputation for performance and reliability in refrigeration. Manufactured in Italy the SH compressors are both quiet and energy efficient. The APS Acpac range has been designed to operate efficiently in both the hot and cold extremes of the Australian environment with large condensers and fan speed control across all models. The Acpac APS range available in capacities from 1.8 to 64.2kW is suitable for both R134a and R404A refrigerant and can be applied in both medium and low temperature applications. The APS Acpac with the Tecumseh semi hermetic compressor is suited to an enormous range of refrigeration applications including reach-in and walkin coolrooms and freezers for food, beverages and other stored products. Typical applications are supermarkets, fast food outlets, pubs and clubs, restaurants and liquor stores. ADDITIONAL FEATURES Tecumseh SH semi hermetic reciprocating compressor Kriwan INT69, INT69 Diagnose or INT TML Diagnose protection module fitted depending on compressor model Part Winding Start (PWS) on larger models Electronic overload/s protect against phase loss, phase imbalance, phase reversal, locked rotor and over current which offers superior compressor protection Cable numbering to make maintenance even easier Oil separator isolation valve Flexible control lines Suction demountable drier shell with filter core fitted Removable compressor transport mounts to protect pipework during transit EC condenser fans on some larger models 6 Acpac Packaged Refrigeration Condensing Units

Semi Hermetic Reciprocating with Variable Speed Drive The variable speed drive (VSD) models of the APS semi hermetic Acpac range include a fully programmed VSD to adjust the compressor speed to maintain the desired evaporating pressure. In extreme ambient temperatures the VSD models will take action to ensure the compressor pressures are maintained within the design operating envelope, this is called HLPS. The APS VSD models are quick and easy to install and commission and are suitable for either R134a or R404A refrigerant. Acpac APS VSD is well suited for refrigerated reach-in and walk-in coolrooms and freezers for every product imaginable including butcher shops, fish shops, fruit and vegetable stores, fast food chains, food processors and many more. ADDITIONAL FEATURES Variable Speed Drive (VSD) is specifically tailored for the HVAC-R Industry Controls the refrigeration system to match the system load at all times, resulting in energy and cost savings Removable keypad that displays up to nine parameters on a single screen Pre-programmed to enable fast commissioning and trouble free operation High Limit Pressure Safety feature. The HLPS feature will keep the compressor inside its operating envelope and allow the compressor to provide the maximum amount of cooling capacity at high ambient conditions The VSD monitors and maintains the compressor within its maximum operating current Oil management speed up feature will ensure oil return is always maintained The EC fans on the larger APS units are controlled via a 0-10V output from the Vacon VSD 7

Semi Hermetic Reciprocating The Octagon semi hermetic compressor from Bitzer has gained a wonderful name throughout the refrigeration industry and provides a great platform for the semi hermetic Acpac. The recently designed Octagon compressor range offers the end user a very reliable, quiet and energy efficient refrigeration condensing unit. This range is especially well suited in situations requiring longer pipe runs between the Acpac and the evaporator/s. The Acpac semi hermetic range is available in refrigeration capacities from 2.0 to 36.7 kw and is designed for both R134a and R404A refrigerant. Acpac semi hermetic is perfect for cooling and freezing applications in pubs and clubs, convenience stores, supermarkets and food processors. ADDITIONAL FEATURES Bitzer Octagon semi hermetic reciprocating compressor Bitzer oil monitoring system on C4 compressor models Bitzer SE-B motor protection on all compressor models Electronic overload protects against phase loss, phase imbalance, phase reversal, locked rotor and over current which offers superior compressor protection Suction accumulator on all models Anti short cycle timer Fan speed control ensures stable operation Suction demountable drier shell on all models 8 Acpac Packaged Refrigeration Condensing Units

Scroll Copeland compliant scroll compressors were chosen for the Acpac scroll series as they are specifically designed for refrigeration duty. The compliant scroll design is inherently quiet, efficient and operates with minimal vibration. This range has been matched with very large condensers/s to further improve the COP (coefficient of performance) resulting on lower running costs. Copeland compliant scroll Acpac ranges from 2.8 to 34.9 kw refrigeration capacity and can be used with R134a or R404A refrigerant. Acpac scroll is designed to be used in a myriad of cooling applications including reach-in and walk-in coolrooms for all unprocessed and processed foods and beverages. Supermarkets, fast food chains, liquor stores, groceries and pubs and clubs are a small sample of typical applications for Acpac scroll. ADDITIONAL FEATURES Copeland ZB scroll compressors Electronic overload protects against phase loss, imbalance, phase reversal, locked rotor and over current which offers excellent compressor protection Suction accumulator on all models Anti short cycle timer Condenser fan speed control for stable operation 9

Technical Data HERMETIC RECIPROCATING - TECUMSEH Product Code Compressor MOC Amps Volts / Phase No. Diam. mm Fan(s) MOC Amps Volts / Phase Liquid Receiver Capacity kg @ 80% Line Size inches Suction Liquid Nett Weight kg Sound Power Level dba MEDIUM TEMPERATURE 2709753 AP1.7M1-4 CAJ9480Z 6.8 240/1 1 x 0 1 x 0.65 2.3 1/2 3/8 68 62 2709754 AP2.1M1-4 CAJ9510Z 8.4 240/1 1 x 0 1 x 0.65 2.3 5/8 3/8 70 63 2709755 AP2.5M1-4 CAJ9513Z 11.3 240/1 1 x 0 1 x 0.65 2.3 5/8 3/8 70 64 2709756 AP2.8M1-4 CAJ4517Z 12.7 240/1 1 x 0 1 x 0.65 2.3 5/8 3/8 71 65 2709757 AP3.9M1-4 CAJ4519Z 15.2 240/1 1 x 0 1 x 0.65 2.3 5/8 3/8 71 68 2709758 AP4.1M1-4 FH4524Z 18.1 240/1 1 x 0 1 x 0.65 3.9 5/8 3/8 81 70 2709759 AP5.7M2-4 TFH4531Z 9 415/3 2 x 0 2 x 0.65 6 5/8 3/8 105 69 240 V Single Phase 2709760 AP7.8M2-4 TFH4540Z 9.2 415/3 2 x 0 2 x 0.65 6 5/8 3/8 118 75 2709761 AP8.8M2-4 TAG4553Z 14 415/3 2 x 0 2 x 0.65 9.5 7/8 1/2 146 78 2709762 AP10.7M2-4 TAG4561Z 15.3 415/3 2 x 0 2 x 0.65 9.5 7/8 1/2 148 78 2709763 AP13.1M2-4 TAG4573Z 19 415/3 2 x 0 2 x 0.65 9.5 7/8 1/2 150 77 LOW TEMPERATURE 2709770 AP1.9L1-4 CAJ2464Z 10.0 240/1 1 x 0 1 x 0.65 2.3 5/8 3/8 73 67 2709771 AP2.9L1-4 FH2480Z 16.0 240/1 1 x 0 1 x 0.65 3.9 5/8 3/8 90 69 2709772 AP3.3L2-4 TFH2511Z 7.2 415/3 2 x 0 2 x 0.65 6 5/8 3/8 130 72 2709773 AP4.8L2-4 TAG2516Z 9.5 415/3 2 x 0 2 x 0.65 6 7/8 1/2 155 71 240V Single Phase 2709774 AP6.2L2-4 TAG2522Z 13.4 415/3 2 x 0 2 x 0.65 9.5 7/8 1/2 175 76 Subtract 17dBA to convert to sound pressure at 3m distance 10 Acpac Packaged Refrigeration Condensing Units

Technical Data SEMI HERMETIC RECIPROCATING - TECUMSEH Product Code Compressor MOC Amps Volts / Phase No. Diam. mm Fan(s) MOC Amps Volts / Phase Liquid Receiver Capacity kg @ 80% Line Size inches Suction Liquid Nett Weight kg Sound Power Level dba MEDIUM / LOW TEMPERATURE 2701982 APS4.6ML2-1 SH4526ZYZ 4.5 DOL 2 x 0 2 x 0.65 6.0 5/8 3/8 161 65 2701983 APS6.0ML2-1 SH4536ZYZ 6.7 DOL 2 x 0 2 x 0.65 6.0 5/8 3/8 168 67 2701984 APS8.3ML2-1 SH4550ZYZ 8.8 DOL 2 x 0 2 x 0.65 6.0 7/8 3/8 180 67 2701985 APS11.7ML3-1 SH4567ZYZ 12.5 DOL 3 x 0 3 x 0.65 9.5 ⅞ 1/2 195 70 2701986 APS14.4ML3-1 SH4591ZYZ 12.7 DOL 3 x 0 3 x 0.65 9.5 ⅞ 1/2 240 70 2701987 APS19.0ML2-1 SH4610ZYZ 17.6 DOL 2 x 500 2 x 3.3 18.0 1 3/8 5/8 290 72 240 V Single Phase 2701988 APS25.8ML2-1 SH4615ZMZ 22.4 PWS 2 x 500 2 x 3.3 18.0 1 3/8 5/8 340 75 2701989 APS33.6ML2-1 SH4620ZMZ.4 PWS 2 x 500 2 x 3.3 18.0 1 3/8 5/8 6 77 2702251 APS39.5ML2-1 SH4623ZMZ.3 PWS 2 x 710 2 x 1.5 415 V Three Phase 25.0 2 1/8 1 1/8 605 78 2702252 APS46.5ML2-1 SH4627ZMZ.5 PWS 2 x 710 2 x 1.5 25.0 2 1/8 1 1/8 615 78 2702253 APS56.4ML2-1 SH46ZMZ 49.2 PWS 2 x 710 2 x 1.5 25.0 2 1/8 1 1/8 650 81 2702254 APS64.2ML2-1 SH4639ZMZ 61.0 PWS 2 x 710 2 x 1.5 25.0 2 1/8 1 1/8 670 82 SEMI HERMETIC RECIPROCATING WITH VSD - TECUMSEH 08002 08004 08007 APS6.0ML2-1VSD APS11.7ML3-1VSD APS25.8ML2-1VSD SH4536ZYZ 6.7 DOL 2 X 0 2 X 0.65 240V Single Phase 6 5/8 3/8 175 67 SH4567ZYZ 12.5 DOL 3 X 0 3 X 0.65 9.5 7/8 1/2 205 70 SH4615ZMZ 22.4 DOL 2 X 500 2 X 3.3 18 1 3/8 5/8 348 75 08011 APS56.4ML2-1VSD SH46ZMZ 49.2 DOL 2 X 710 2 X 1.5 415V Three Phase 25 2 1/8 1 1/8 660 81 Subtract 17dBA to convert to sound pressure at 3m distance 11

Technical Data SEMI HERMETIC RECIPROCATING - BITZER Product Code Compressor MOC Amps Volts / Phase No. Diam. mm Fan(s) MOC Amps Volts / Phase Liquid Receiver Capacity kg @ 80% Line Size inches Suction Liquid Nett Weight kg Sound Power Level dba MEDIUM / LOW TEMPERATURE 2709801 APB4.9ML2-4 2GES-2Y 4.5 415/3 2 x 0 2 x 0.65 6.0 5/8 3/8 170 68 2709802 APB6.0ML2-4 2FES-3Y 8.9 415/3 2 x 0 2 x 0.65 6.0 5/8 3/8 175 68 2709803 APB8.5ML2-4 2DES-3Y 7.6 415/3 2 x 0 2 x 0.65 6.0 7/8 3/8 200 69 2709804 APB11.5ML3-4 4FES-5Y 10.3 415/3 3 x 0 3 x 0.65 9.5 7/8 1/2 230 71 2709805 APB15.8ML3-4 4DES-7Y 15.1 415/3 3 x 0 3 x 0.65 9.5 7/8 1/2 250 72 2709806 APB20.8ML2-4 4CES-9Y 18.0 415/3 2 x 500 2 x 3.30 12 1 1/8 5/8 290 79 2709807 APB25.8ML2-4 4TES-12Y 21.5 415/3 2 x 500 2 x 3.30 12 1 3/8 5/8 0 79 240 V Single Phase 2709808 APB29.6ML2-4 4PES-15Y 24.7 415/3 2 x 500 2 x 3.30 12 1 3/8 5/8 360 79 2709809 APB36.7ML2-4 4NES-20Y 29.0 415/3 2 x 500 2 x 3.30 12 1 3/8 5/8 390 80 Subtract 17dBA to convert to sound pressure at 3m distance 12 Acpac Packaged Refrigeration Condensing Units

Technical Data SCROLL - COPELAND Product Code Compressor MOC Amps Volts / Phase No. Diam. mm Fan(s) MOC Amps Volts / Phase Liquid Receiver Capacity kg @ 80% Line Size inches Suction Liquid Nett Weight kg Sound Power Level dba MEDIUM TEMPERATURE 2709777 APC4.6M1-4 ZB15KQE 16 240/1 1 x 0 1 x 0.65 3.9 5/8 3/8 70 66 2709778 APC5.7M2-4 ZB19KQE 6 415/3 2 x 0 2 x 0.65 6.0 5/8 3/8 131 68 2709779 APC7.9M2-4 ZB26KQE 10 415/3 2 x 0 2 x 0.65 6.0 5/8 3/8 133 69 2709780 APC11.5M3-4 ZBKQE 12.5 415/3 3 x 0 3 x 0.65 9.5 7/8 1/2 163 70 2709782 APC14.4M3-4 ZB48KQE 17 415/3 3 x 0 3 x 0.65 9.5 7/8 1/2 167 73 2709783 APC18.3M2-4 ZB58KQE 23 415/3 2 x 500 2 x 3.3 12 1 1/8 5/8 241 77 2709784 APC20.3M2-4 ZB66KQE 24.2 415/3 2 x 500 2 x 3.3 12 1 1/8 5/8 242 77 240 V Single Phase 2709785 APC24.7M2-4 ZB76KQE 26.9 415/3 2 x 500 2 x 3.3 12 1 1/8 5/8 245 78 2709786 APC29.7M2-4 ZB95KQE 27.8 415/3 2 x 500 2 x 3.3 12 1 1/8 5/8 305 82 2709787 APC34.9M2-4 ZB114KQE 31.4 415/3 2 x 500 2 x 3.3 12 1 1/8 5/8 314 83 Subtract 17dBA to convert to sound pressure at 3m distance 13

14 Acpac Packaged Refrigeration Condensing Units Capacity Data HERMETIC RECIPROCATING - TECUMSEH R404A Medium Temperature Applications Ambient Temp. C Saturated Suction Temperature: C -15-10 -5 0 5 10 15 AP1.7M1-4 1229 1162 1087 973 1521 1417 19 1195 1785 1696 1591 16 2118 1995 1893 1712 2452 2309 2194 1985 2796 2666 2502 2264 3141 2997 2808 2539 AP2.1M1-4 1482 1406 1318 1183 1796 1706 1617 1441 2156 2031 1927 1739 2517 2370 2250 20 2882 2747 2573 22 3087 2885 2601 3633 3402 41 2924 AP2.5M1-4 1680 1589 1476 1319 2107 1970 1865 1675 2536 2412 2254 20 2978 28 2655 2398 00 78 3125 2823 3960 3792 37 3196 92 4217 3920 40 AP2.8M1-4 2019 1896 1796 1613 2428 2280 2161 1942 2870 27 2555 2297 33 3168 3015 2719 91 3422 3084 4272 4092 3797 3417 4797 4457 4271 3697 AP3.9M1-4 2527 2392 2236 1994 3103 2944 2759 2473 3761 41 35 3017 4444 4180 3963 65 5168 4923 4603 4139 5926 5646 5371 4734 6831 6390 6086 5485 AP4.1M1-4 2767 2598 2394 2085 06 69 3075 2720 4266 3987 3763 31 5077 4827 4489 4010 60 5639 5361 4688 6936 6470 6163 5544 7840 7515 6964 6274 AP5.7M2-4 3957 3647 3412 2969 4836 4483 4222 3725 5741 5454 5051 4652 6782 64 6012 5393 7669 7298 6777 6091 8479 8122 7534 6778 9458 8796 8424 AP7.8M2-4 5766 54 4982 4240 6720 6244 5876 5189 7796 7401 6876 6127 8946 8516 7933 7110 10305 9650 9184 8087 11484 10746 102 92 12573 12042 11204 10103 AP8.8M2-4 5873 5420 5073 13 72 6719 68 5585 8786 8349 7736 6886 10634 9915 94 8467 12284 11762 10916 9823 14228 141 12691 11029 15622 14478 13907 AP10.7M2-4 7260 6823 67 57 8852 8220 7740 68 10575 10046 92 8306 12696 11860 11276 9876 14663 13692 13053 11762 16539 15858 14723 172 18783 17466 16758 AP13.1M2-4 9210 8455 7930 6897 10757 10194 9367 8246 12848 11923 11314 9765 14784 14131 13075 11712 17189 15978 14767 152 19017 17623 16902 20502 19790 Capacities based on 18 o C return vapour and 3 K sub cooling

Capacity Data HERMETIC RECIPROCATING - TECUMSEH R404A Low Temperature Application Ambient Temp. C Saturated Suction Temperature: C -40 - -30-23.3-20 -15-10 AP1.9L1-4 912 851 795 692 1200 1125 1057 939 1531 1448 15 1213 1963 1861 1757 1567 2078 1972 1855 1660 2252 2139 2003 1802 2675 2545 21 2146 AP2.9L1-4 857 755 593 1271 1158 1056 875 1741 1613 1496 1289 2467 27 2174 1911 2852 2697 25 2236 18 3307 3128 2804 4209 4007 3754 3378 AP3.3L2-4 1730 1556 1413 1148 20 1892 1708 17 2503 2346 2146 1853 3390 3178 2986 2606 3910 3642 31 3046 47 4497 4177 3728 5617 53 4952 44 AP4.8L2-4 2100 1900 1726 1403 2634 2418 2224 1875 3406 3194 2929 25 4792 4494 4184 3689 5590 5211 4907 45 6865 6404 6050 5399 8212 7792 7241 6482 AP6.2L2-4 2970 2678 20 1973 67 67 3004 2529 4455 4177 28 3307 6088 5710 5316 4687 7037 6562 6180 5485 8563 7992 7549 6739 10179 9667 8987 8046 Capacities based on 18 o C return vapour and 3 K sub cooling 15

Capacity Data SEMI HERMETIC RECIPROCATING - TECUMSEH R404A Medium / Low Temperature Application Ambient Temp. C Saturated Suction Temperature: C -40 - -30-25 -20-15 -10-5 0 5 APS4.6ML2-1 708 656 602 513 998 928 856 739 1361 1270 1178 1018 1803 1690 1576 13 28 2202 2059 1818 3000 2802 2629 23 3746 12 3302 2941 4598 49 4073 3653 5566 5286 4962 4467 6711 6333 6017 5457 APS6.0ML2-1 1049 974 899 16 19 1349 1809 1263 1692 1116 1500 2518 26 2209 1967 04 3006 2825 2522 4006 3785 39 3169 4921 4657 47 3904 6004 5644 5339 4803 7168 6748 6399 5778 8452 8058 7572 6869 APS8.3ML2-1 2610 2418 2245 1960 3455 21 3014 2665 4424 4165 89 3460 5530 5220 4878 61 6787 6421 6054 5374 8266 7756 73 6596 9841 92 8757 7887 11561 11013 10311 9318 APS11.7ML2-1 49 4139 3942 3625 5502 52 4983 4573 6797 6481 6145 5623 8252 7868 7448 6795 9863 9399 8936 8125 11702 11066 10519 9550 13627 12996 12228 11079 15680 14957 14051 12717 APS14.4ML2-1 2597 2364 2139 3621 3339 3078 4840 4492 4178 3637 6268 5885 5459 4798 7925 7462 6928 6120 9901 9247 8698 7718 12041 112 10598 9427 148 13647 12687 11304 17218 16078 15250 20003 18671 17755 APS19.0ML2-1 6618 6246 5893 5289 8502 8052 7621 6876 10674 10110 9585 8677 13148 12510 11808 10699 15923 15158 106 12959 19004 18099 17067 15467 22559 219 20278 18396 26279 24827 23625 21447 APS25.8ML2-1 8859 8265 7731 6819 11449 10711 10067 8948 14415 13631 127 118 17748 16829 15761 14144 21667 203 19318 17418 25792 24274 23059 20849 30248 28870 27106 24570 516 33464 31939 28539 APS33.6ML2-1 APS39.5ML2-1 APS46.5ML2-1 APS56.4ML2-1 APS64.2ML2-1 6612 5983 50 9486 8802 8159 12548 11810 11112 9899 15915 15136 14272 12894 7003 6421 5815 4863 9823 9145 8470 78 7886 11059 7188 10234 6456 9414 9907 9120 8304 7071 128 11622 10405 13711 12762 11820 97 18006 16668 136 12366 11551 10171 14959 179 12892 11223 18403 171 15991 14068 237 22249 20850 15397 12054 18479 17186 16130 15146 13461 19523 18191 16997 14957 23910 22344 209 18562 30185 28591 26851 24175 19642 18726 17706 16090 21774 20484 19297 17250 24866 23408 21800 196 30360 284 26745 2 370 509 33451 30360 23773 22687 21605 19545 27019 25610 240 21565 31036 29316 274 241 37806 767 33469 29964 451 163 40984 37054 28523 27047 25764 23489 936 31270 290 263 062 36058 34059 30169 46284 909 411 36991 54524 51536 49030 44752 33604 113 30319 27616 39541 37591 656 31876 46465 639 416 37250 56364 53088 50365 45562 64190 61182 57750 52779 39133 37399 251 083 47215 44569 423 4 55390 52782 49506 44794 67137 63309 60246 54679 74569 71192 67082 614 45642 092 411 37202 55264 52174 496 45019 65161 62291 58505 53198 78991 75555 71193 64928 86701 81817 78068 Requires additional fan compressor cooling Capacities based on 20 o C return vapour and 0 K sub cooling 16 Acpac Packaged Refrigeration Condensing Units

17 SEMI HERMETIC RECIPROCATING - TECUMSEH R134a Medium / Low Temperature Application Ambient Temp. C Saturated Suction Temperature: C -30-25 -20-15 -10-5 0 5 10 12.5 APS4.6ML2-1 701 649 595 515 988 1331 1267 1201 1093 17 1662 1582 1464 2221 2125 20 1888 2788 2674 2568 2393 34 3303 3177 2968 4178 4016 76 3629 5016 4846 4666 78 5253 5218 4822 4524 929 869 780 APS6.0ML2-1 1098 1028 956 1488 1411 1336 1200 1980 1882 1786 1631 2566 2446 23 62 3118 2982 2754 4065 3901 3727 3454 4981 4789 4579 4251 6001 5779 5557 5147 7174 6886 6624 6173 7680 7052 7008 6558 2148 APS8.3ML2-1 2599 2461 2330 2109 30 3188 3033 2766 4265 4067 78 58 5348 5123 4883 4503 6604 6339 6045 5591 8031 7724 7417 6877 9682 9274 8919 8296 10292 9416 9370 8758 APS11.7ML2-1 2055 1885 1705 1406 2861 2685 2509 2200 30 3620 3424 4950 4716 4493 4112 6267 5991 5734 5289 7790 7490 7160 66 9529 9179 8795 8174 11514 11100 10689 9963 13784 1 12762 11924 14584 13408 13360 12540 3094 APS14.4ML2-1 03 75 3364 3009 5009 4745 4499 4078 6477 6159 5866 5362 8203 7859 7481 6886 10206 9803 93 8642 12533 11999 11531 10708 15077 14453 13917 12962 15747 15715 149 13427 APS19.0ML2-1 5407 5156 4907 4477 7018 6718 6419 5912 8992 8614 8250 7629 11304 10848 10408 9658 14003 13451 12921 12024 17099 16480 15808 147 20605 19878 19080 17812 21116 20968 20847 19570 APS25.8ML2-1 4539 4213 71 3349 6199 5826 8267 7799 7367 6644 10702 10156 9655 8804 161 12919 12337 11337 16858 16178 15428 14266 20600 19821 18951 17596 24918 23910 23024 21472 29592 284 274 25669 30819 30758 28274 26583 5456 4841 APS33.6ML2-1 6160 5744 5306 4608 8282 7847 10810 10312 9836 13770 13188 126 11701 17226 16584 15900 14791 21241 20480 19658 18340 25840 24937 23953 22377 31166 29984 28922 27070 370 645 34407 228 40222 897 37367 013 7414 6677 9020 APS39.5ML2-1 7152 97 9191 8615 7679 12815 12212 11608 10577 16495 15769 15078 13903 20785 19939 191 17757 25788 24780 229 22199 31553 30440 29228 27292 126 36814 0 33096 45546 44009 42477 39803 49754 47918 46270 2 6622 6070 5173 APS46.5ML2-1 7076 6606 6120 5336 9461 8974 8470 7657 12313 11775 11237 108 18378 17412 165 15074 253 223 21336 19566 29511 28228 26854 24740 36263 34773 33123 30607 792 42074 40362 37416 52447 501 48193 44776 56945 54455 527 48728 APS56.4ML2-1 8975 86 7774 6787 124 11650 10978 9828 16400 15614 14831 110 21318 20340 19412 178 27051 25875 24772 22897 33678 274 30965 28729 41219 39680 018 1 49711 47919 45951 42864 59404 57100 55042 51458 64521 62037 598 55995 APS64.2ML2-1 12398 11580 10722 95 16473 15626 14779 1 21397 20413 19477 17878 27181 26047 24971 231 33962 702 312 29185 41816 401 707 36123 50801 49019 47244 994 61152 58830 56736 53086 725 69775 67319 63017 78666 76034 73016 68368 Requires additional fan compressor cooling Capacities based on 20 o C return vapour and 0 K sub cooling Capacity Data

18 Acpac Packaged Refrigeration Condensing Units SEMI HERMETIC RECIPROCATING WITH VSD - TECUMSEH R404A Medium / Low Temperature Application Hz Ambient Temp. C Saturated Suction Temperature: C -40 - -30-25 -20-15 -10-5 0 5 APS6.0ML2-1VSD 30 629 584 539 862 809 758 670 1161 1085 1015 900 1511 1414 15 1180 1922 1804 1695 1513 2404 2271 2123 1901 2953 2794 2614 2342 3602 36 03 2882 01 4049 39 3467 5071 48 45 4121 50 1049 974 899 16 1349 1263 1116 19 1809 1692 1500 2518 26 2209 1967 04 3006 2825 2522 4006 3785 39 3169 4921 4657 47 3904 6004 5644 5339 4803 7168 6748 6399 5778 8452 8058 7572 6869 60 1259 1169 1079 1723 1619 1516 1339 22 2171 2030 1800 3022 2827 2651 2360 45 3607 3390 3026 4807 4542 4247 03 5905 5588 5228 4685 7205 6773 6407 5764 8602 8098 7679 6934 10142 9670 9086 82 APS11.7ML3-1VSD 30 2609 2483 2365 2175 3301 3139 2990 2744 4078 89 3687 3374 4951 4721 4469 4077 5918 5639 5362 4875 7021 6640 6311 5730 8176 7798 7337 6647 9408 8974 81 7630 50 49 4139 3942 3625 5502 52 4983 4573 6797 6481 6145 5623 8252 7868 7448 6795 9863 9399 8936 8125 11702 11066 10519 9550 13627 12996 12228 11079 15680 14957 14051 12717 60 5219 4967 4730 40 6602 6278 5980 5488 8156 7777 7374 6748 9902 9442 89 8154 11836 11279 10723 9750 14042 179 12623 11460 162 15595 14674 195 18816 17948 16861 15260 APS25.8ML2-1VSD 30 5315 4959 4639 4091 6870 6427 6040 5369 8649 8179 7646 6833 10649 10097 9457 8486 13000 12230 11591 10451 15475 14564 1 12509 18149 172 16264 14742 21310 20078 19163 17123 50 8859 8265 7731 6819 11449 10711 10067 8948 14415 13631 127 118 17748 16829 15761 14144 21667 203 19318 17418 25792 24274 23059 20849 30248 28870 27106 24570 516 33464 31939 28539 60 10631 9918 9277 8183 13739 12853 12080 107 17298 167 15292 13666 21297 20195 18913 16973 26000 24460 23182 20902 30950 29129 27671 25019 36297 34644 527 29484 42619 40157 7 34247 APS56.4ML2-1VSD 30 5944 5472 4982 42 8227 7657 7092 5846 11042 10286 9595 8441 146 13406 12566 11137 18216 17060 16047 101 22684 21460 20081 17978 27770 26345 24686 22195 318 31853 30219 27337 40282 37985 36148 807 47395 45333 42716 956 50 9907 9120 8304 7071 13711 12762 11820 97 18403 171 15991 14068 23910 22344 209 18562 30360 284 26745 2 37806 767 33469 29964 46284 909 411 36991 56364 53088 50365 45562 67137 63309 60246 54679 78991 75555 71193 64926 60 11888 10944 9965 8485 16453 15314 14184 11692 22084 20572 19189 16882 28692 26813 251 22274 364 34121 094 28602 45367 42920 40163 957 55541 52691 49372 449 67637 63706 604 54674 80564 75971 72295 65615 94789 90666 854 77911 Capacities based on 20 o C return vapour and 0 K sub cooling Capacity Data

19 SEMI HERMETIC RECIPROCATING WITH VSD - TECUMSEH R134a Medium / Low Temperature Application Hz Ambient Temp. C Saturated Suction Temperature: C -30-25 -20-15 -10-5 0 5 10 12.5 APS6.0ML2-1VSD 30 659 617 574 893 847 802 720 1188 1129 1072 979 1540 1468 1401 1289 1957 1871 1789 1652 29 2341 2236 2072 2989 2873 2747 2551 3601 3467 3334 3088 04 41 3974 3704 4608 4231 4205 39 50 1098 1028 956 1488 1411 1336 1200 1980 1882 1786 1631 2566 2446 23 2148 62 3118 2982 2754 4065 3901 3727 3454 4981 4789 4579 4251 6001 5779 5557 5147 7174 6886 6624 6173 7680 7052 7008 6558 60 1318 1234 1147 1786 1693 1603 1440 2376 2258 21 1957 3079 29 2802 2578 3914 3742 78 3305 4878 4681 4472 4145 5977 5747 5495 5105 7201 69 6668 6176 8609 8263 7949 7408 9216 8462 8410 7870 APS11.7ML3-1VSD 30 1233 1131 1023 844 1717 1611 1505 10 2298 2172 2054 1856 2970 2830 2696 2467 3760 95 3440 3173 4674 4494 4296 3983 5717 5507 5277 4904 6908 6660 6413 5978 8270 79 7657 7154 8750 8045 8016 7524 50 2055 1885 1705 1406 2861 2685 2509 2200 30 3620 3424 3094 4950 4716 4493 4112 6267 5991 5734 5289 7790 7490 7160 66 9529 9179 8795 8174 11514 11100 10689 9963 13784 1 12762 11924 14584 13408 13360 12540 60 2466 2262 2046 1687 33 22 3011 2640 4596 44 4109 3713 5940 5659 5392 4934 7520 7189 6881 6347 9348 8988 8592 7966 114 11015 10554 9809 117 130 12827 11956 16541 15886 15314 108 17501 16090 160 15048 APS25.8ML2-1VSD 30 2724 2528 23 2009 3719 3496 74 2905 4960 4679 4420 3987 6421 6094 5793 5282 8137 7751 7402 6802 10115 9707 9257 8559 12360 11893 11371 10557 14951 146 115 12883 17755 17061 16460 15402 18491 17855 16964 15950 50 4539 4213 71 3349 6199 5826 5456 4841 8267 7799 7367 6644 10702 10156 9655 8804 161 12919 12337 11337 16858 16178 15428 14266 20600 19821 18951 17596 24918 23910 23024 21472 29592 284 274 25669 30819 29758 28274 26583 60 5447 5055 4645 4019 79 6991 6547 5809 9920 99 8841 7973 12842 12187 11586 10564 16273 15503 14804 13604 20229 19413 18513 17119 24720 23786 22742 21115 29901 28692 27629 25766 511 34121 920 30803 36983 710 33929 31900 APS56.4ML2-1VSD 30 53 50 4664 37 7394 6990 6587 5504 9840 9368 8899 7620 12791 12204 11647 10123 16231 15525 14863 13040 20207 19364 18579 16460 24731 208 22811 20315 29827 28751 27571 24656 642 34260 33025 29500 713 37222 903 114 50 8975 86 7774 6220 124 11650 10978 9173 16400 15614 14831 12700 21318 20340 19412 16872 27051 25875 24772 21733 33678 274 30965 273 41219 39680 018 9 49711 47919 45951 41093 59404 57100 55042 49166 64521 62037 598 523 60 10770 10063 99 7464 14789 13980 13174 11008 19680 18737 17797 15240 25582 24480 294 20246 461 31050 29726 26080 40414 729 37158 920 49463 47616 45622 40631 59653 57503 55141 491 71285 68520 66050 58999 77425 74444 71806 64228 Capacities based on 20 o C return vapour and 0 K sub cooling Capacity Data

Capacity Data SEMI HERMETIC RECIPROCATING - BITZER R404A Medium / Low Temperature Application Ambient Temp. C Saturated Suction Temperature: C -40 - -30-25 -20-15 -10-5 0 5 APB4.9ML2-4 931 858 783 666 1288 1201 1114 965 1707 1601 1496 11 2200 2065 1939 1728 2758 2596 2447 2194 3394 3199 3024 2723 4111 3902 3673 3317 4913 4670 98 3980 5802 5521 5241 4710 6840 6458 61 5563 APB6.0ML2-4 1191 1096 997 845 1625 1514 1404 1220 2142 2002 1872 1650 27 2564 2409 2145 3407 06 3023 2709 4172 3956 3717 33 5028 4777 4493 4051 5979 5686 5394 4876 7085 6685 6347 5740 8241 7855 7379 6671 APB8.5ML2-4 1684 1556 1428 1204 2315 2150 1997 17 3037 2840 2658 2347 70 3633 3417 3046 4818 4562 4279 5888 5587 5251 4728 7082 67 61 5715 8468 7994 7590 6871 9931 9370 8905 8066 11513 10984 10318 9342 APB11.5ML3-4 2312 2141 1970 1675 3150 2944 2739 2396 41 77 36 18 5268 4949 4657 4160 6551 6204 5823 5229 7997 7590 7134 6429 9612 9136 8663 7763 11488 10844 10296 93 13469 12706 12078 10941 15616 14899 13995 12675 APB15.8ML3-4 33 2960 2718 2319 4453 4123 3348 5856 5502 5111 4521 7448 7030 6554 58 9229 8739 8250 7400 11311 10623 10055 9046 13495 128 12017 10831 15837 15085 14108 12721 18615 17453 16611 21261 20330 18947 APB20.8ML2-4 60 4056 3752 27 5887 5505 5146 4530 7641 7186 6762 6034 9660 9113 8612 7748 11960 11361 10712 9684 14550 146 13067 11849 176 16615 15792 14240 20782 19664 18708 17003 215 22980 21876 19873 28129 26862 25277 22933 APB25.8ML2-4 5020 4640 4264 36 7013 6510 6056 5283 9285 8670 8125 7186 11881 11221 10481 9346 14807 14026 13129 11766 18231 17146 162 14609 21865 20560 19498 17572 25797 24573 23007 20740 29974 28578 26704 24052 34966 730 31177 APB29.6ML2-4 5773 5317 4896 4144 8117 7546 7016 6080 10806 10182 9444 8294 148 13084 12184 10787 172 162 15416 152 21190 19880 18808 16841 25287 24074 22465 20146 29647 282 263 23607 34826 554 30988 39565 37869 112 APB36.7ML2-4 6817 6304 5794 4882 9645 8945 8305 7205 12867 11999 11219 9864 16549 15493 14558 12920 20718 19612 18345 168 25393 24101 22589 20273 30874 29081 27591 24884 36655 34541 819 29648 42928 40988 464 34764 50393 47425 45257 Requires additional fan compressor cooling Capacities based on 20 o C return vapour and 0 K sub cooling 20 Acpac Packaged Refrigeration Condensing Units

Capacity Data SEMI HERMETIC RECIPROCATING - BITZER R134a Medium / Low Temperature Application No. Ambient Temp. C Saturated Suction Temperature: C -30-25 -20-15 -10-5 0 5 10 12.5 APB4.9ML2-4 801 753 705 630 1122 1065 1008 919 1504 14 1371 1260 1952 1870 1794 1660 2475 2377 2287 2127 3081 2964 2859 2668 3779 3639 16 89 4577 44 4269 3999 5483 5317 5124 4802 5981 5804 5593 52 APB6.0ML2-4 1006 936 865 766 1407 12 1244 1117 1884 1781 1689 1534 2442 2318 2211 2022 3092 2942 2818 2588 40 3660 17 40 4694 4518 18 3984 5660 5464 5224 4824 6816 6529 6241 5830 7421 7107 6794 64 APB8.5ML2-4 1419 1330 1241 1115 1958 1851 1753 1592 2599 2470 24 2158 32 3196 3061 2822 4226 4039 83 94 5236 5041 48 4483 67 6168 5916 5497 7690 7448 7147 6644 9248 8888 8527 8015 10063 9669 9276 8730 APB11.5ML3-4 1828 1704 1580 1410 2568 2421 2285 2071 3449 73 3116 2855 4486 4275 4094 3776 5695 5441 52 4846 7090 6827 6546 6079 8686 89 8050 7485 10492 10162 9754 9074 12648 12158 11668 10968 13778 142 12706 11957 APB15.8ML3-4 2927 2739 2575 2298 4031 05 3615 76 5331 5061 4841 4427 6846 6569 6268 5765 8589 8277 7912 7303 10572 10227 9786 9141 12956 12427 11897 11154 15514 14880 14246 13403 183 17581 17088 15880 19845 19018 18521 17200 APB20.8ML2-4 3661 3440 19 2902 5020 4754 4508 4102 6634 6312 6024 5526 8530 8142 7804 7195 107 10270 9874 9133 180 12796 12258 11361 16184 15631 14982 13900 19468 18844 18064 16766 2 22452 21519 20195 250 24410 23391 21971 APB25.8ML2-4 4146 19 3062 5920 5544 5222 4622 8011 7563 7186 6461 10453 9918 9477 8604 178 12755 12125 11075 16509 15905 15151 194 20379 19478 18577 17296 24559 23485 22411 20929 29208 27931 26655 24948 31709 30318 28926 27100 APB29.6ML2-4 4913 4506 4168 21 69 6463 6078 54 93 8785 8345 7459 12149 11631 11001 9953 15412 14821 14073 12827 19141 18468 17578 164 23647 22586 21526 20081 284 27174 25910 24251 33712 206 31301 28810 36519 34877 33944 31221 APB36.7ML2-4 5513 5055 4597 3939 8022 7483 7016 6158 10974 10339 9797 8768 14420 13671 13040 11809 18408 17525 16789 151 22983 221 21084 19336 28188 27204 25960 285 394 919 31444 29369 41040 39295 37550 154 44633 42736 40839 266 Requires additional fan compressor cooling Capacities based on 20 o C return vapour and 0 K sub cooling 21

Capacity Data SCROLL - COPELAND R404A Medium Temperature Application APC4.6M1-4 APC5.7M2-4 APC7.9M2-4 APC11.5M3-4 APC14.4M3-4 APC18.3M2-4 APC20.3M2-4 APC24.7M2-4 APC29.7M2-4 APC34.9M2-4 Ambient Temp. C Saturated Suction Temperature: C -15-10 -5 0 5 10 85 31 3001 2711 4008 33 3653 39 5615 5375 5105 4662 81 7800 7410 67 10310 9830 9346 8471 12744 12195 11595 10493 194 13783 13123 12012 17303 16583 15836 14537 21011 200 18904 16862 240 23086 21724 195 90 3710 44 51 4827 4616 76 4030 6665 64 6084 5554 9712 9291 8841 8075 12260 11660 11082 10078 15379 14745 14055 12865 17181 16466 15686 140 20776 19926 19056 17554 25192 24098 22880 20711 29295 27909 26503 23912 4604 94 4186 29 5722 5478 5208 4780 7915 7587 7250 6630 11536 10996 10498 9600 14418 13776 13026 11827 18285 17548 167 158 20254 19408 18552 16993 24694 23721 22641 208 29740 28492 27229 24871 34863 33159 31577 28686 56 5129 4859 4444 6677 6413 6136 5621 93 8888 8490 7791 142 12912 123 11316 16763 16015 15115 13755 21580 20620 19751 18189 202 22662 21674 19889 29007 27880 26620 24544 34892 33302 31846 29179 40805 855 37083 6 6178 5933 5633 5148 7867 7477 7154 6600 10861 101 9912 9111 15723 15073 1 13182 19478 18458 17622 16030 251 23992 22968 21113 27558 262 25077 23003 33925 425 31093 28675 407 553 36890 6 47265 450 040 390 7120 6760 6476 5952 9069 8649 8303 7670 12548 12070 11470 10542 18074 17369 16529 152 28976 27842 25022 200 31606 30344 28784 26448 39168 37428 877 33062 46524 44692 42406 36393 49995 48022 45556 41787 Requires additional fan compressor cooling Capacities based on 20 o C return vapour and 0 K sub cooling 22 Acpac Packaged Refrigeration Condensing Units

Capacity Data SCROLL - COPELAND R134a Medium Temperature Application Ambient Temp. C Saturated Suction Temperature: C -15-10 -5 0 5 10 APC4.6M1-4 1857 1797 1737 24 2252 2175 2046 2860 2778 2688 2533 3488 33 69 3094 4195 4071 3946 3724 5004 4848 4701 4441 APC5.7M2-4 2172 2100 2030 2718 2634 2551 2409 3364 62 3158 2980 4108 3988 66 3655 4963 4823 4667 4414 5929 5760 5574 5275 APC7.9M2-4 3150 3048 2947 3942 16 3696 3490 4869 4719 4573 41 5942 5768 5582 5279 7168 6964 6742 6375 8553 8306 8055 7624 APC11.5M3-4 4539 95 4252 5726 5552 51 5089 7075 6859 6655 6299 8622 8376 8118 7683 101 10082 9776 9259 12397 12036 11678 11056 APC14.4M3-4 5776 5565 55 74 7057 6749 6287 9061 8780 8489 7885 10965 10633 10289 9606 131 12702 12292 11574 15554 15075 14539 13694 APC18.3M2-4 7119 6885 6654 8886 8604 84 7848 10954 10594 10259 9691 192 12902 12497 11812 15995 15530 15020 14196 18972 187 17867 16908 APC20.3M2-4 8122 7858 7597 10091 9779 9460 8915 12416 12026 11648 10982 15122 14661 14181 13401 181 17616 17046 16126 215 209 20319 19217 APC24.7M2-4 93 9083 8786 11696 11336 10970 10331 14461 14011 156 12765 17578 170 16512 15610 21161 20501 19901 18821 25125 240 23650 22392 APC29.7M2-4 11812 113 10847 14765 14285 13761 12805 18205 176 17030 15978 22078 219 20719 19517 26534 25772 249 202 31582 30648 29703 28003 APC34.9M2-4 13750 110 12661 171 16781 16147 15040 21511 20815 20095 18827 26228 253 24593 23148 31518 30622 29717 27996 37524 364 228 5 Requires additional fan compressor cooling Capacities based on 18 o C return vapour and 3 K sub cooling 23

Physical Data Hermetic - Tecumseh Semi Hermetic - Tecumseh Product Code See Figure Product Code See Figure 2709753 AP1.7M1-4 1 2701982 APS4.6ML2-1 2 2709754 AP2.1M1-4 1 2701983 APS6.0ML2-1 2 2709755 AP2.5M1-4 1 2701984 APS8.3ML2-1 2 2709756 AP2.8M1-4 1 2701985 APS11.7ML3-1 3 2709757 AP3.9M1-4 1 2701986 APS14.4ML3-1 3 2709758 AP4.1M1-4 1 2701987 APS19.0ML2-1 4 2709759 AP5.7M2-4 2 2701988 APS25.8ML2-1 4 2709760 AP7.8M2-4 2 2701989 APS33.6ML2-1 4 2709761 AP8.8M2-4 2 2702251 APS39.5ML2-1 5 2709762 AP10.7M2-4 2 2702252 APS46.5ML2-1 5 2709763 AP13.1M2-4 2 2702253 APS56.4ML2-1 5 2709770 AP1.9L1-4 1 2702254 APS64.2ML2-1 5 2709771 AP2.9L1-4 1 2709772 AP.3.3L2-4 2 2709773 AP4.8L2-4 2 Semi Hermetic with VSD - Tecumseh Product Code See Figure 2709774 AP6.2L2-4 2 08002 APS6.0ML2-1 VSD 2 08004 APS11.7ML3-1 VSD 3 08007 APS25.8ML2-1 VSD 4 08011 APS56.4ML2-1 VSD 5 24 Acpac Packaged Refrigeration Condensing Units

Semi Hermetic - Bitzer Copeland Scroll Product Code See Figure Product Code See Figure 2709801 APB4.9ML2-4 2 2709777 APC4.6M1-4 1 2709802 APB6.0ML2-4 2 2709778 APC5.7M2-4 2 2709803 APB8.5ML2-4 2 2709779 APC7.9M2-4 2 2709804 APB11.5ML3-4 3 2709780 APC11.5M3-4 3 2709805 APB15.8ML3-4 3 2709782 APC14.4M3-4 3 2709806 APB20.8ML2-4 4 2709783 APC18.3M2-4 4 2709807 APB25.8ML2-4 4 2709784 APC20.3M2-4 4 2709808 APB29.6ML2-4 4 2709785 APC24.7M2-4 4 2709809 APB36.7ML2-4 4 2709786 APC29.7M2-4 4 2709787 APC34.9M2-4 4 Please see following pages for figure drawings. 25

Physical Data FIGURE 1 (1 x 0mm Fan) 1030 Figure 1.0 486 440 1070 Figure 1.1 653.5 Figure 1.2 737 For wiring and installation instructions visit www.actrol.com.au Allow sufficient space for service work. Minimum distance from wall on condenser side of unit = 1/2 fan diameter, 1 fan diameter recommended 26 Acpac Packaged Refrigeration Condensing Units

Physical Data FIGURE 2 (2 x 0mm Fan) 981 231 Figure 2.0 584 597 627 1424 Figure 2.1 56 611 Figure 2.2 750 For wiring and installation instructions visit www.actrol.com.au Allow sufficient space for service work. Minimum distance from wall on condenser side of unit = 1/2 fan diameter, 1 fan diameter recommended 27

Physical Data FIGURE 3 (3 x 0mm Fan) 665 657 244 108 Figure 3.0 584 597 627 1884 Figure 3.1 56 611 Figure 3.2 750 For wiring and installation instructions visit www.actrol.com.au Allow sufficient space for service work. Minimum distance from wall on condenser side of unit = 1/2 fan diameter, 1 fan diameter recommended 28 Acpac Packaged Refrigeration Condensing Units

Physical Data FIGURE 4 (2 x 500mm Fan) 1262 283 121 Figure 4.0 1779 Figure 4.1 62 826 818 830 870 Figure 4.2 1002 For wiring and installation instructions visit www.actrol.com.au Allow sufficient space for service work. Minimum distance from wall on condenser side of unit = 1/2 fan diameter, 1 fan diameter recommended 29

Physical Data FIGURE 5 (2 x 710mm Fan) 294 944 941 148 Figure 5.0 1051 1071 1101 2455 Figure 5.1 62 1224 Figure 5.2 15 For wiring and installation instructions visit www.actrol.com.au Allow sufficient space for service work. Minimum distance from wall on condenser side of unit = 1/2 fan diameter, 1 fan diameter recommended 30 Acpac Packaged Refrigeration Condensing Units

actrol.com.au Actrol. Works for you. Call 1800 ACTROL or visit www.actrol.com.au for your nearest branch. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. The manufacturer/distributor takes no responsibility for printing errors. All dimensions are nominal only. V1 [BROCHURE CODE 2101545]