EC FX NH3. A new and improved approach to ammonia gas detection

Similar documents
EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

SPM Flex Chemcassette Tape-Based Gas Detector

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

Fixed-Point Industrial Gas Detection

Zareba System Overview

Touchpoint Plus. A whole new control experience

SPM Flex Chemcassette Tape-Based Gas Detector

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

XNX Universal Transmitter

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

White Paper. Building a Better Ammonia Sensor A new and improved approach to ammonia gas detection

Fixed-Point Industrial Gas Detection

Sieger Apex. Flexibility that meets your requirements

Life Safety Network. Intelligent solutions for advanced requirements

Searchpoint Optima Plus

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Operating Instructions

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

EXAMPLES OF HOW TO ORDER

Gas Detection. Touchpoint Plus. A whole new control experience

White Paper. Critical Considerations for Monitoring Low Levels of Hydrogen Sulfide. by Jacob Spector and Kirk Johnson

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

EXAMPLES OF HOW TO ORDER

System 57. An advanced World of intelligent gas detection system management

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Danfoss gas detection unit Type GD Heavy Duty

Warranty Registration

System 57. An advanced world of intelligent gas detection system management

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Recalibrate the way you look at gas detection

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sensepoint XCL Fixed Gas Detector

MicroRAE. Wireless, Portable Four-Gas Detector. Gas Detection

Two-Channel Gas Controller

MeshGuard and MeshGuard Gamma

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Carbon Monoxide Transmitter

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Touchpoint Pro Flexible Gas Control System

Safe Operation Manual. Honeywell IQ Force Gas Detector

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

Touchpoint Plus. A whole new control experience

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

LC1350 Level Controller

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

Zareba Sensepoint Pro

CO and NO 2 Monitoring Systems for Parking Structures

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

safe and your operations compliant

Hydrazine Analyzer Series 2171 Specifications

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Lumidor portable gas detection. Portable protection from hazardous gas

incontrol Systems Inc. Flame and Gas Detection

Technical Manual. LeakFilm Pro. Single Channel Conductive and Chemical Liquid Leak Detection Controller with Leak Location Detection

ALTAIR 5X Multigas Detector

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

SAM-MAX Refrigerant Monitors

Sieger fixed gas detection. Fixed protection from hazardous gas

Model Q45P/R. ph/orp Monitor...

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

altair 2X Gas Detectors

Oxygen (O2) Single-Point Gas Detection System

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

ALTAIR 2X Gas Detectors It s what s inside that really counts

Warranty Registration

Honeywell Analytics. Order List BW Clip & IntelliDoX

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

altair 2X Gas Detectors

IMR IX176 Portable Gas Detector User Manual

DGS - Danfoss Gas Sensor Check / Calibration Procedure

Dew-Point Transmitters and Instruments

MeshGuard and MeshGuard Gamma

Gas Detection. ConneXt Loneworker Real-time visibility on the safety, location and productivity of your isolated workers

Transcription:

EC FX NH3 A new and improved approach to ammonia gas detection

EC-FX-NH3 Sensor & Transmitter better, tougher, introducing a longer-lasting sensor for industrial refrigeration Breakthrough technology, only from Honeywell Analytics. In response to the challenging conditions found in Industrial Refrigeration, Honeywell Analytics has developed an innovative new ammonia detector delivering reliability, accuracy and long-lasting performance that you can t get anywhere else. The EC FX NH3, an evolution of our Manning EC F9 NH3, features an all-new ammonia sensor with a proprietary electrolyte that stands up to harsh environments. So whether you re monitoring ammonia in blast freezers, cold storage or engine rooms, you can feel confident in the effectiveness of your gas detection system, helping you ensure life safety, prevent food spoilage and manage costs.

EC-FX-NH3 User Environments Three harsh environments. One tough sensor. If you use ammonia as part of your refrigeration process, you face several challenges in protecting your plant from the danger and expense of ammonia leaks: Cold Storage From banana rooms to ice cream storage to food processing facilities, your cold storage areas are subject to extremely low temperatures plus changes in humidity during cleaning and changes in pressure due to opening and closing doors. These fluctuations can cause some ammonia sensors to produce faults or false alarms. As workers are often present in these areas, it s critical for ammonia sensors to stand up to tough conditions and accurately report gas at low levels. Refrigerated Processing Areas Some of the harshest environments in the food industry are spiral freezers and blast freezers, where rapid freezing often means drastic changes in temperature. This temperature shock along with rapid humidity swings from hot-water washdowns can further challenge the performance of your ammonia sensors. Engine Rooms The most likely place for a catastrophic ammonia leak is in your engine room, since they typically hold ammonia for use throughout your plant. In the hot conditions of most engine rooms, the liquid electrolyte in standard ammonia sensor cells can dry out quickly, sometimes reducing the sensor s life span and causing false alarms. The EC-FX sensor, with its proprietary electrolyte, differentiates itself in this environment by maintaining sensitivity despite high temperatures and background ammonia. Maintaining sensitivity and accuracy even with rapid changes in temperature and humidity

EC-FX-NH3 Three-Year Warranty extended three-year warranty for the next generation in ammonia sensors We stand behind our products. We are so confident in the performance of our new sensor that it comes with a three-year warranty twice the warranty of most competing sensors. Our proprietary new EC-FX sensor, backed by rigorous testing, was engineered to Honeywell s highest standards of safety, reliability and cost-effectiveness: Stability you can count on. Unlike other ammonia sensors, our new sensor maintains sensitivity even during rapid changes in temperature and humidity. While other sensors may quickly lose sensitivity after exposure to ammonia gas, our EC FX sensor bounces back from alarm-level gas exposure and resumes accurate detection. So you can rest assured that your ammonia sensors are protecting lives and operations. Lower cost of ownership. Fewer sensor replacements means a lower cost of ownership over time. In fact, if you re currently using our EC F9 or EC F2 transmitter, you can significantly cut your costs by switching your current sensor for the new EC FX sensor. Over a 10-year period, you can save up to $2,500 per sensor in an engine room and up to $1,300 per sensor in cold storage and blast freezers. Proprietary technology for longer life and lower costs EC FX NH3 with Stainless Steel enclosure and LCD options

EC-FX-NH3 Lifespan, Capabilities & Design Longer life span. Thanks to our proprietary technology, the EC FX sensor lasts up to 18 months longer than competitors and we back it up with the longest warranty on the market. See how it compares: Application Competing Sensors EC FX Sensor Cold storage and freezers Replace once or more every two years Replace once every four to five years Engine rooms Replace every six to 18 months Replace once every three to four years And if you re using an ammonia gas detector from another manufacturer, you can potentially save even more by switching to the EC FX NH3 transmitter with the all-new sensor. Over a 10-year period, you can cut costs by up to $5,500 per sensor in the engine room and $2,800 per sensor in cold storage and blast freezers. Depending on the number of ammonia gas detectors in your operations, that longer sensor life can add up to serious savings. Robust capabilities with unique design The EC FX NH3 responds quickly to ammonia gas concentrations in low parts per million (PPM). You can count on this detector to stand up to the challenges of industrial refrigeration environments. Rugged construction for long-term reliability. Unlike fragile plastic housings that may break in cold temperatures, the heavy-duty steel enclosure of the EC FX NH3 was built to withstand cold and wet environments. The EC FX NH3 is also available in stainless steel. ATMOS Technology for environmental flexibility. The EC FX NH3 automatically adapts to its environment and can operate in -50 F and 100 percent humidity. So whether you re monitoring ammonia in a banana room or a blast freezer, during dry conditions or a hot-water washdown, the detector maintains accurate and reliable performance. SensorCheck Technology for peace of mind. The EC FX NH3 is equipped with a microprocessor that checks the electrical viability of the sensor every 24 hours. If there s a problem, SensorCheck sends an indication to your controller so you can rest assured that the sensor is operating properly. Optional LCD for real-time visibility. With an easy-to-read display, you can clearly see the ammonia concentration at any given time. The optional display also makes it easy to set alarm levels and change settings all from the detector. Backwards compatible. The EC-FX sensor is backwards compatible with both EC-F9-NH3 and EC-F2-NH3. Add it up, and our new EC FX NH3 gas detector housing an all-new, proprietary ammonia sensor from Honeywell Analytics is the new gold standard for reliability, accuracy and long-term performance in ammonia gas detection.

EC-FX-NH3 Transmitter Specifications General Specification Use Common Operation Operation LCD display (optional) Output Accuracy Environmental IP rating Operational Humidity Temperature Sensor Pressure Limit Storage Common Module Communication Power Source Repeatability Electrochemical (diffusion) type sensor that works in conjunction with any Honeywell Analytics readout or alarm unit. Readouts have built in visual and audible alarms, as well as relay output for ventilation fan activation, central alarm tie-in, etc. The EC-FX-NH3 can provide a linear 4/20 ma signal input into PLC s. In units without the optional LCD module, a group of LEDs are installed to the PCB. In units with the optional LCD, two external push buttons, Accept and Scroll are used to navigate test functions and operating modes. 2 line by 8 alpha numeric characters and continuous backlight Isolated 4/20 ma, 700 ohms max. at 24 VDC. Signal output reduces to 0.5 ma to indicate a fault condition. RS-485, Modbus RTU protocol ±5% full scale* Indoor use, IP 44 in accordance with EN60529:1992 5-100% RH (condensing) -50 F to +120 F (-45 C to +49 C), ATMOS equipped enviro-adaptive technology required for refrigerated areas or outdoors 0-10 PSIG -40 F to +176 F (-40 C to +80 C), 20 to 80%RH (non condensing) 4/20 ma output: #18/3 shielded cable (Belden 8770 or equal), cable runs < 1,500 ft. RS-485: for communication cable, use 24 AWG twisted pair, shielded (Belden #9841 or equal), cable runs up to 2,000 ft. For power cable use 14 AWG (Belden #5100UE or equal), cable runs up to 1,000 feet. 24 VDC, 0.5 amp max. <10% of full scale Sensor Specifications Sensor Pressure Limit Atmospheric ±10% Response Time (T90) <30 s Ranges 0-100 ppm, 0-200 ppm, 0-250 ppm Sensor Warranty Three years from date of shipment Sensor Viability Test SensorCheck, an internal microprocessor determines the sensor s electrical viability every 24 hours. If the viability test fails, a 0.5 ma signal will idicate a fault. An internal light will show if a sensor is dried up or disconnected. Enclosure Weight NEMA 1, gasketed, #16 gauge steel (standard). Stainless steel, including modified enclosures for low temperatures, ventilation ducts, etc. are available. 3 lbs. * ±5% of full scale range at temperature of calibration. Contact HA for additional details. CAUTION: EC-FX is designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapors is avoided, both during storage, fitting into instruments, and operation. EC-FX is designed to be used in safety critical applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check). Failure to carry out such tests on a regular basis may jeopardize the safety of people and property.

EC-FX-NH3 Creating a New Standard the gold standard in ammonia detection with innovation you can trust Creating a new standard of reliability in ammonia gas detection The EC FX NH3 is the next evolution of the proven Manning Systems technology, which was designed specifically for the extreme conditions of fruit and vegetable processing, bakeries, meat and poultry processing, beverage and bottling plants, and more. In fact, our Manning EC F9-NH3 and EC F2-NH3 products have been the most-installed ammonia gas detectors in the refrigeration industry. Now, with the all-new EC FX NH3 from Honeywell Analytics, we re making that great technology even better. isn t it time you upgraded to the most innovative, longest-lasting technology for ammonia detection? Contact Honeywell Analytics today to upgrade your ammonia sensors, reduce your costs, and ensure the continued safety and productivity of your plant.

Honeywell Analytics Gas Detection Offerings Honeywell Analytics gas detectors protect people, assets and environment from toxic and combustible gas hazards, helping to create safer, more comfortable, secure and productive environments. Our strength derives from Honeywell s leadership in sensor technology; in fact Honeywell operates four sensor manufacturing plants, supplying an entire industry with its core detective element. Commercial Gas detection from standalone units to fully engineered, multi-point systems, all offering cost-effective regulatory compliance.» Applications: parking structures, chillers, mechanical rooms, office towers, commercial buildings, shopping centers, swimming pools, golf courses, schools and universities, laboratories Industrial Renowned Sieger and Manning gas detection systems with advanced electrochemical, infrared and open path sensing technologies.» Applications: oil and gas, cold storage, water/wastewater treatment, chemicals, engine rooms, plastics and fibers, agriculture, printing and light industrial Portables Single or multi-gas detectors ranging from compact, lightweight designs for personal protection to systems-based, networkable instrumentation for industrial hygiene.» Applications: underground utility and electricity ducts, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first responder teams, remote fleets Customer business centre Korea #701 Kolon Science Valley (1) 43 Digital-Ro 34-Gil, Guro-Gu Seoul 152-729 Korea Tel: +82 (0)2 6909 0300 Fax: +82 (0)2 2025 0329 Analytics.ap@honeywell.com Singapore Level 1, Honeywell Building, 17 Changi Business Park Central 1 Singapore 486073 Tel: +65-65803776 Fax: +65-65803663 Australia Unit 1B, 69 Dalton Road Thomastown, Victoria 3074 Tel: +61-3-94642770 Fax: +61-3-94642772 Taiwan 5F-10, No.81,Shui Li Road Hsin Chu, Taiwan Tel: +886-3-5169284 Fax: +886-3-5169339 High Tech/Government Reliable gas and chemical detection including infrared spectroscopy (MST) with no cross interference, to Chemcassette paper-based solutions (MDA Scientific) offering detection down to parts per billion.» Applications: semiconductor manufacturing, aerospace propulsion, specialty chemicals industry, research laboratories, emergency response Technical Services AP: ha.ap.service@honeywell.com EMEA: ha.emea.service@honeywell.com US: ha.us.service@honeywell.com Technical Services 24/7 global network includes post-sales service and Systems Integration teams.» Emergency call out, service contracts, on/off-site repair, training and commissioning» Complete range of spares, consumables and accessories Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. BRO1162-EN-AP_v2 11/14 2014 Honeywell International Inc.