Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Similar documents
Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller.

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Chilled Water System.

Chilled Water System. All Product Brochure

Chilled Water System Solution

Wall Mounted Split Systems

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Ultimate energy saving technology

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Compact design & easy maintenance

Air cooled industrial chillers

Air Cooled Scroll Chiller

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

INVERTER Y SINGLE SPLIT SERIES II

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

KELVIN Clim F497. Kelvin air conditioning

Ultimate energy saving technology

kw MRT150C Coming MRT180C MRT240C MRT300C

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

MAC-120HE-03 Air-Cooled Chiller

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

.2 Section Waste Management and Disposal.

Mini unitary chiller. Mini unitary chiller

Galletti Water chillers and heat pumps catalogue

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Remote Air Cooled Condensers C2 Series

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

EHH SERIES DRAW THROUGH FAN COILS CFM

Advance Split

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

PRODUCT GUIDE

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

SCROLL COMPRESSORS TYPE AIR COOLED PACKAGE CHILLERS

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Models: A5HDC20AR A5HDC25AR. Horizontal Ducted Condensing Unit

500 EX Fusion Compressor Series

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

H4T R410A. refrigerant

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

pyxis pyxisa NEW rcgroupairconditioning

Water Chiller Solutions. A solution to every water cooling need.

HYDRONIC RESIDENTIAL

Air-Cooled Mini Chiller and Heat Pump

pyxis u pyxis ua NEW rcgroupairconditioning

Modular Air Cooled Chiller

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Unit Width. 900mm. Service Space Internal Header. 1st. Unit. 2nd. Coupling supplied as standard. Unit

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

Blue Box Epsilon Echos +

PYXIS U PYXIS U. rcgroupairconditioning

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n

Modular Air Cooled Chiller

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Call us today! (800)

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

SyScroll Air EVO NEW

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Superchiller Product Documentation. English. cod rev Issued by TDS

Transcription:

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 10 CR A5ACV - 007 Air-Cooled Chiller (R410A Inverter Series)

1. NOMENCLATURE Production spec variation Type of ref. connection X : Not applicable Electrical A : 0-40V/1Ph/50Hz F : 380-415V/3Ph/50Hz A 5 AC V 100 C R - F X AA Model Type R : heatpump Omitted if cooling Series C : C series Capacity 100 : 100,000 Btu/h Type Inverter Model Name AC : Air cooled mini chiller Refrigerant 5 : R410A Brand Acson 1

. FEATURES TRUE DUAL CIRCUITS BPHE The true dual BPHE puts the secondary circuit (water) in contact with primary circuits (refrigerant). So even if one primary circuit is shut off, each secondary channel is still in contact with a primary channel. INVERTER Inverter compressor is programmed to run at the optimum speed, which is regulated by the input frequency as it can varies according to the heat load requirement. Inverter advantages are : Less start & stop Frequency regulated compressor resulting in lesser in the sense of start and stop of compressor, which greatly reduces the energy consumption. Fast cooling/heating Inverter compressor has the ability to produce faster cooling/heating capacity at the frequency higher than the dominant capacity frequency. Smart loading/unloading with the integration of built in system algorithm; inverter compressor could control the system s loading and unloading sophisticatedly. Better compressor reliability Reliability of inverter compressor is always better since there is lesser on/ off of the system especially during low load condition. ELIMITION OF WATER TANK Inverter system provides constant water temperature band, or much lesser water temperature fluctuation. With this, water tank of the mini chiller system can be eliminated. BUILT IN FAN SPEED The built in algorithm now controls fan speed, resulting in cost saving since installation of external FSC (Fan speed controller) can be exempted. SAFETY PROCTECTION High & low pressure switches Anti-freeze protection sensor Discharge temperature sensor Over pressure relief valve Water pressure differential switch Anti-freeze heater on BPHE Compressor, water pump overload protector ANTI CORROSION HEAT EXCHANGER Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller. MODULAR INSTALLATION A network up to 50chillers in a system is possible. Control on the operation of the chillers will be done through the microprocessor controller. The external water piping connection can be made either from the left or right side of the unit. 3

6. ENGINEERING AND PHYSICAL DATA GENERAL DATA - HEAT R410A INVERTER A5ACV 30CR A5ACV 55CR NOMIL COOLING CAPACITY Btu/h 7000 50000 W 7913 14654 NOMIL HEATING CAPACITY Btu/h 33000 55000 W 9663 16119 NOMIL TOTAL INPUT POWER COOLING W 579 7600 HEATING W 4418 6100 NOMIL RUNNING CURRENT COOLING A 19.9 15. HEATING A 17.3 13.1 POWER SOURCE V/Ph/Hz 0-40 / 1 / 50 380-415 / 3 / 50 REFRIGERANT R410A CONTROL ELECTRONIC EXPANSION VALVE HEIGHT mm/in 790 / 31.1 1410 / 55.5 UNIT DIMENSION WIDTH mm/in 1010 / 39.8 1010 / 39.8 DEPTH mm/in 460 / 18.1 460 / 18.1 HEIGHT mm/in 90 / 36. 1551 / 61.1 PACKING DIMENSION WIDTH mm/in 104 / 47.4 104 / 47.4 DEPTH mm/in 570 /.4 570 /.4 UNIT WEIGHT kg/lb 18 / 8 195 / 430 SOUND PRESSURE LEVEL dba 59 6 EVAPORATOR NOMIL WATER FLOW COOLING l/s / m 3 /hr 0.3 ( 1.3 ) 0.7 (.5 ) HEATING l/s / m 3 /hr 0.4 ( 1.5 ) 0.8 (.7 ) FAN /DRIVE PROPELLER / DIRECT QUANTITY 1 HYDRAULIC KIT MAX. WATER OPER. PRESSURE kpa / psi 1000 / 145 WATER FLOW RATE COOLING l/s / m 3 /hr 0.3 ( 1.3 ) 0.7 (.5 ) HEATING l/s / m 3 /hr 0.4 ( 1.5 ) 0.8 (.7 ) INSTALLATION PIPE CONNECITON mm/in 5.4 / 1 PIPING HEAD COOLING m 7.7 1.7 HEATING m 7.0 11.5 TANK CAPACITY/VOLUME L / ft 3 STAGE OF CAPACITY CONTROL (Btu/h) 0-8700 0-55000 REFRIGERANT CHARGING MASS kg/lb.1 4.1 ) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO1353. 3) NOMIL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 1 C / 7 C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35 C AIR AMBIENT TEMPERATURE. b) HEATING - 40 C / 45 C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7 C AIR AMBIENT TEMPERATURE. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 53

GENERAL DATA - HEAT R410A INVERTER A5ACV75CR NOMIL COOLING CAPACITY Btu/h 70000 W 0515 NOMIL HEATING CAPACITY Btu/h 75000 W 1980 NOMIL TOTAL INPUT POWER COOLING W 9050 HEATING W 7900 NOMIL RUNNING CURRENT COOLING A 16.6 HEATING A 15.4 POWER SOURCE REFRIGERANT CONTROL V/Ph/Hz 380-415 / 3 / 50 R410A ELECTRONIC EXPANSION VALVE HEIGHT mm/in 1460 / 57.5 UNIT DIMENSION WIDTH mm/in 1150 / 45.3 DEPTH mm/in 550 / 1.7 HEIGHT mm/in 166 / 64.0 PACKING DIMENSION WIDTH mm/in 1309 / 51.5 DEPTH mm/in 656 / 5.8 UNIT WEIGHT kg/lb 00 / 440 SOUND PRESSURE LEVEL dba 65 EVAPORATOR NOMIL WATER FLOW COOLING l/s / m 3 /hr 0.9 ( 3.4 ) FAN HEATING l/s / m 3 /hr 1.0 ( 3.7 ) /DRIVE QUANTITY HYDRAULIC KIT PROPELLER / DIRECT MAX. WATER OPER. PRESSURE kpa / psi 1000 / 145 WATER FLOW RATE COOLING l/s / m 3 /hr 0.9 ( 3.4 ) HEATING l/s / m 3 /hr 1.0 ( 3.7 ) INSTALLATION PIPE CONNECITON mm/in 5.4 / 1 PIPING HEAD COOLING m.3 HEATING m 1.3 TANK CAPACITY/VOLUME L / ft 3 STAGE OF CAPACITY CONTROL (Btu/h) 0-75000 REFRIGERANT CHARGING MASS kg/lb 4.8 ) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO1353. 3) NOMIL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 1 C / 7 C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35 C AIR AMBIENT TEMPERATURE. b) HEATING - 40 C / 45 C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7 C AIR AMBIENT TEMPERATURE. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 54

GENERAL DATA - HEAT R410A INVERTER A5ACV100CR A5ACV135CR NOMIL COOLING CAPACITY Btu/h 95000 131500 W 7800 38540 NOMIL HEATING CAPACITY Btu/h 100000 141500 W 9300 41470 NOMIL TOTAL INPUT POWER COOLING W 1000 15750 HEATING W 11400 1650 NOMIL RUNNING CURRENT COOLING A 4.4 30.0 HEATING A 3.9 31.4 POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 REFRIGERANT R410A CONTROL ELECTRONIC EXPANSION VALVE / CAPILLARY TUBE HEIGHT mm/in 160 / 49.6 160 / 49.6 UNIT DIMENSION WIDTH mm/in 1500 / 59.1 1800 / 70.9 DEPTH mm/in 900 / 35.4 1150 / 45.3 HEIGHT mm/in 145 / 57. 145 / 57. PACKING DIMENSION WIDTH mm/in 173 / 68. 03 / 80.0 DEPTH mm/in 103 / 40.6 18 / 50.5 UNIT WEIGHT kg/lb 360 / 794 560 / 135 SOUND PRESSURE LEVEL dba 63 67 EVAPORATOR NOMIL WATER FLOW COOLING l/s / m 3 /hr 1.3 ( 4.8 ) 1.8 ( 6.6 ) HEATING l/s / m 3 /hr 1.4 ( 5.0 ).0 ( 7.1 ) FAN /DRIVE PROPELLER / DIRECT QUANTITY HYDRAULIC KIT MAX. WATER OPER. PRESSURE kpa / psi 1000 / 145 WATER FLOW RATE COOLING l/s / m 3 /hr 1.3 ( 4.8 ) 1.8 ( 6.6 ) HEATING l/s / m 3 /hr 1.4 ( 5.0 ).0 ( 7.1 ) INSTALLATION PIPE CONNECITON mm/in 31.75 / 1 1/4 PIPING HEAD COOLING m 17.3 16.5 HEATING m 15.7 14.5 TANK CAPACITY/VOLUME L / ft 3 STAGE OF CAPACITY CONTROL (Btu/h) 73000-1000 99000-149000 REFRIGERANT CHARGING MASS kg/lb 4.7 x / 10.4 x 6.0 x / 13. x ) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO1353. 3) NOMIL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 1 C / 7 C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35 C AIR AMBIENT TEMPERATURE. b) HEATING - 40 C / 45 C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7 C AIR AMBIENT TEMPERATURE. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 55

GENERAL DATA - HEAT R410A INVERTER A5ACV10CR NOMIL COOLING CAPACITY Btu/h 00000 W 5856 NOMIL HEATING CAPACITY Btu/h 10000 W 61490 NOMIL TOTAL INPUT POWER COOLING W 300 HEATING W 1800 NOMIL RUNNING CURRENT COOLING A 44.6 HEATING A 44.6 POWER SOURCE REFRIGERANT CONTROL V/Ph/Hz 380-415 / 3 / 50 R410A ELECTRONIC EXPANSION VALVE HEIGHT mm/in 1786 / 70.3 UNIT DIMENSION WIDTH mm/in 093 / 8.4 DEPTH mm/in 119 / 46.9 HEIGHT mm/in 1975 / 77.7 PACKING DIMENSION WIDTH mm/in 176 / 85.6 DEPTH mm/in 1300 / 51. UNIT WEIGHT kg/lb 64 / 1415 SOUND PRESSURE LEVEL dba 85 EVAPORATOR NOMIL WATER FLOW COOLING l/s / m 3 /hr.7 ( 9.6 ) FAN HEATING l/s / m 3 /hr.9 ( 10.3 ) /DRIVE QUANTITY HYDRAULIC KIT PROPELLER / DIRECT MAX. WATER OPER. PRESSURE kpa / psi 1000 / 145 WATER FLOW RATE COOLING l/s / m 3 /hr.7 ( 9.6 ) HEATING l/s / m 3 /hr.9 ( 10.3 ) INSTALLATION PIPE CONNECITON mm/in 38 / 1 1/ PIPING HEAD COOLING m 5.0 HEATING m 5.0 TANK CAPACITY/VOLUME L / ft 3 STAGE OF CAPACITY CONTROL (Btu/h) 0-10000 REFRIGERANT CHARGING MASS COOLING kg/lb 9.5 / 0.9 HEATING kg/lb 8.5 / 18.7 ) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO1353. 3) NOMIL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 1 C / 7 C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35 C AIR AMBIENT TEMPERATURE. b) HEATING - 40 C / 45 C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7 C AIR AMBIENT TEMPERATURE. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 56

COMPONENTS DATA FAN FAN MOTOR COIL BPHE CASING A5ACV 30CR A5ACV 55CR PROPELLER 1 ALUMINIUM DRIVE DIRECT DIAMETER mm/in 457. / 18 INDUCTION 1 INDEX OF PROTECTION (IP) AC INVERTER OIL OIL INVERTER AMOUNT cm 3 / fl.oz. 1700 / 57.5 300 / 77.8 CROSS FINNED TUBES INNER GROOVED COPPER TUBE DIAMETER mm/in 9.5 / 3/8 THICKNESS mm/in 0.37 / 0.015 CORRUGATED ALUMINIUM THICKNESS mm/in 0.1 / 0.005 FIN FACE AREA m / ft 0.65 / 7.0 1.17 / 1.6 ROW FIN PER INCH 16 BRAZED PLATE HEAT EXCHANGER STAINLESS STEEL CAST IRON & STAINLESS STEEL ELECTRO-GALVANIZED MILD STEEL COLOUR LIGHT GREY- PE775104 FAN FAN MOTOR COIL BPHE CASING A5ACV75CR DRIVE PROPELLER ALUMINIUM DIRECT DIAMETER INDEX OF PROTECTION (IP) OIL mm/in 609.6 / 4 INDUCTION AC INVERTER OIL INVERTER AMOUNT cm 3 / fl.oz. 300 / 77.8 CROSS FINNED TUBES INNER GROOVED COPPER TUBE DIAMETER mm/in 9.5 / 3/8 THICKNESS mm/in 0.37 / 0.015 CORRUGATED ALUMINIUM THICKNESS mm/in 0.1 / 0.005 FIN COLOUR FACE AREA ROW FIN PER INCH m / ft 1.7 / 13.7 16 BRAZED PLATE HEAT EXCHANGER STAINLESS STEEL CAST IRON & STAINLESS STEEL ELECTRO-GALVANIZED MILD STEEL LIGHT GREY- PE775104 57

COMPONENTS DATA FAN FAN MOTOR COIL BPHE CASING DRIVE DIAMETER INDEX OF PROTECTION (IP) OIL OIL AMOUNT TUBE FIN COLOUR A5ACV100CR A5ACV135CR mm/in 609.6 / 4 660.4 / 6 cm 3 / fl.oz. 1700 / 57.5 350 / 110 INVERTER S. cm 3 / fl.oz. 300 / 77.8 300 / 77.8 DIAMETER THICKNESS mm/in mm/in THICKNESS mm/in 0.1 / 0.005 FACE AREA m / ft 1.37 / 14.7 1.79 / 19.3 ROW FIN PER INCH PROPELLER ALUMINIUM DIRECT INDUCTION + AC INVERTER CROSS FINNED TUBES CORRUGATED INNER GROOVED COPPER 9.5 / 3/8 0.37 / 0.015 ALUMINIUM 14 BRAZED PLATE HEAT EXCHANGER STAINLESS STEEL CAST IRON & STAINLESS STEEL ELECTRO-GALVANIZED MILD STEEL LIGHT GREY- PE775104 58

COMPONENTS DATA FAN FAN MOTOR COIL BPHE CASING A5ACV10CR DRIVE PROPELLER ALUMINIUM DIRECT DIAMETER INDEX OF PROTECTION (IP) OIL mm/in 81.8 / 3 INDUCTION AC INVERTER OIL INVERTER AMOUNT cm 3 / fl.oz. 300 / 77.8 CROSS FINNED TUBES INNER GROOVED COPPER TUBE DIAMETER mm/in 9.5 / 3/8 THICKNESS mm/in 0.37 / 0.015 ALUMINIUM (HYDROPHILIC GOLD FIN) THICKNESS mm/in 0.1 / 0.005 FIN COLOUR FACE AREA ROW FIN PER INCH m / ft.66 / 8.6 16 BRAZED PLATE HEAT EXCHANGER STAINLESS STEEL CAST IRON & STAINLESS STEEL ELECTRO-GALVANIZED MILD STEEL LIGHT GREY- PE775104 59