CO 2 cooling for HEP experiments

Similar documents
CO 2 COOLING FOR THE LHCB-VELO EXPERIMENT AT CERN.

DESIGN, MANUFACTURE AND TEST RESULTS OF THE VTCS CO 2 EVAPORATOR FOR THE LHCB EXPERIMENT AT CERN.

PoS(Vertex 2007)009. CO 2 cooling experience (LHCb) Martin van Beuzekom, Ann Van Lysebetten 1, Bart Verlaat

Cooling test results C-side replacement detector

Operational aspects of the VELO cooling system of LHCb

CO 2 Cooling Seminar Desy Hamburg

THE THERMOSIPHON COOLING SYSTEM OF THE ATLAS EXPERIMENT AT THE CERN LARGE HADRON COLLIDER

Global Journal of Engineering Science and Research Management

TRACI, A MULTIPURPOSE CO 2 COOLING SYSTEM FOR R&D

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

2. HEAT EXCHANGERS MESA

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

(Refer Slide Time: 00:00:40 min)

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Performance of an Improved Household Refrigerator/Freezer

4th IIR International Conference on Thermophysical Properties and Transfer Processes of Refrigerants 2013

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

VTCS evaporator block design and prototyping. Status report July 2004

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Pressure Enthalpy Charts

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Development of the Micro Capillary Pumped Loop for Electronic Cooling

In the name of God. Jami Institute of Jami - Mehdi Rasti

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Implementation of Microchannel Evaporator for High-Heat-Flux Refrigeration Cooling Applications

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Optimization of Various Thermal Management Techniques for High Thermal Loads

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

of the liquid prior to it entering the expansion device. By doing so, the capacity for

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Thermal Management by Immersion Cooling

Heat sinks for electronic cooling applications

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Compendium DES July 2016, CARN

20. Cooling Techniques for High Density Electronics (2)

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

CHAPTER 1 INTRODUCTION

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Air-Cooled Thermosyphon for Press-Pack Stack of Semiconductors

Enhancement of COP in Vapour Compression Refrigeration System

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Investigation of Evaporator Performance with and without Liquid Overfeeding

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

2.2. General view of Microchannel Heat Exchangers

Week 9. Refrigeration Cycles I. GENESYS Laboratory

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

MODULE 6 HUMIDIFICATION AND AIR CONDITIONING

PoS(ICHEP2012)516. The status of the CMS pixel upgrade detector

Compression of Fins pipe and simple Heat pipe Using CFD

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Design, Manufacturing of Chilled Water System for Process Cooling Application

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

MECHANICAL SCIENCE Module 2 Heat Exchangers

Transcription:

CO cooling for HEP experiments B. Verlaat, M. Van Beuzekom, A. Van ysebetten Nikhef, Kruislaan 49, 198 SJ Amsterdam, The Netherlands bverlaat@nikhef.nl Abstract The new generation silicon detectors require more efficient cooling of the front-end electronics and the silicon sensors themselves. To minimize reverse annealing of the silicon sensors the cooling temperatures need to be reduced. Other important requirements of the new generation cooling systems are a reduced mass and a maintenance free operation of the hardware inside the detector. Evaporative CO cooling systems are ideal for this purpose as they need smaller tubes than conventional systems. The heat transfer capability of evaporative CO is high. CO is used as cooling fluid for the HCb-VEO and the AMS-Tracker cooling systems. A special method for the fluid circulation is developed at Nikhef to get a very stable temperature of both detectors without any active components like valves or heaters inside. This method is called -phase Accumulator Controlled oop (PAC) and is a good candidate technology for the design of the future cooling systems for the Atlas and CMS upgrades. I. EVAPORATIVE CO COOING In detector applications it is crucial to minimize the hardware needed for the cooling inside the detectors. It is known that two-phase cooling is more efficient than single phase cooling. ess flow is needed and a tube can become almost isothermal when the pressure drop remains low. The smallest diameter evaporator tubes can be achieved with fluids which are evaporating under high pressure. For these fluids, the created vapor can not expand to a large volume. Therefore the pipe volume hence the diameter can stay low. A smaller diameter pipe contains less fluid mass. A high pressure fluid needs a thicker tube wall, but since the pipe diameter is smaller, the increase in mass of the tube wall is compensated by the diameter decrease. Hence, the total mass (tube+fluid) is lower when using a high pressure fluid as compared to a low pressure fluid. Another good feature of high pressure fluids is that larger pressure drops can be allowed. The influence of the pressure drop is related to the absolute pressure, and therefore less significant for high pressure fluids. This means that even smaller diameter tubes can be used. Currently used radiation hard fluids are fluor-carbons and CO. Figure 1 shows the saturation pressure curves of some these fluids in the temperature range between +1 and -4 C. As can be seen, CO is the best candidate of the three and the least interesting candidate fluid. A calculation later in this paper will show the superiority of CO compared to the two fluor-carbons. Pressure (Bar) 75 5 5-6 -4 - Temperature ( C) CO C F 6 4 Figure 1: Saturation curves of radiation hard cooling fluids A. Temperature distribution in an evaporative cooling tube. The pressure along a cooling tube drops in the direction of the flow. This results for two-phase flow in a decrease in temperature due to the decrease of the saturation pressure. In contradictory for single phase flow the temperature increases along the tube due to the heat capacity. Figure shows a typical temperature distribution over a cooling tube with CO starting in single phase at the inlet and ending in gaseous phase at the outlet. Temperature ( C) Pressure (Bar) 9 6 3-3 iquid Sub cooled liquid Enthalpy (J/kg) ow T -phase Fluid temperature Target flow condition -phase liquid / vapor Isotherm Tube temperature Dry-out zone Gas Increasing T Super heated vapor Figure : The principle of two-phase cooling versus single phase cooling At the lower graph the temperature along a tube is shown, with the increasing temperature in the two single phase regions and a decreasing temperature profile in the two-phase 38

region. The black line is the fluid temperature, while the red line is the tube wall temperature. The difference between them is caused by the heat transfer resistance. In the region where the evaporation starts, the heat transfer resistance and hence the temperature difference is low. At a certain vapor quality the heat transfer can get suddenly worse causing a rapidly increasing wall temperature. (Vapor quality is the mass fraction of vapour to liquid in a two-phase flow). The wall temperature increase is due to the fact that the remaining liquid is no longer touching the tube wall which results in a poor heat transfer resistance. This phenomenon is called dryout. During a cooling cycle two main parameters change: energy is added or released in the form of enthalpy and pressure is lowered by expansion or increased by pumping or compression. Due to the change of these properties the other important features like the temperature are derived. Setting a temperature directly is not possible; it is achieved by setting the right enthalpy and pressure to achieve the desired temperature. For this reason cooling systems are designed in the pressure-enthalpy diagram of the corresponding fluid. In the top panel of Figure a CO pressure enthalpy diagram shown. The temperature distribution over the tube and the fluid state in the lower panel can be read from this diagram. B. Pressure drop and heat transfer Two-phase pressure drop as well as two-phase heat transfer is hard to predict accurately as the liquid/vapor flow pattern are very non-uniform. The existing prediction methods are all based on empirical correlations of data fitting in certain operational areas. A lot of research is done on low-pressure fluids in macro tubes, while our applications use high pressure and mini channels. Only a few research results are available for each of these subjects and results on the combination of the two are even harder to find. The calculations in the example in this paper are based on research from several years ago. Although more recent and hence more accurate models have become available in the mean time, it does not influence the comparison of different cooling fluids. Petterson et al [1] used the Friedel correlation for pressure drop and the Kandlikar correlation for heat transfer during their research of CO in micro channel tubes for automotive air-conditioning in. In both correlations the two-phase formula is the single phase formula multiplied by a correlation factor. An overview of all the relevant equations and parameters are given in chapter VII and VIII. The two-phase pressure drop can be calculated with equation 1: P = φ * P (1) TP O O P O is the pressure drop of single phase liquid with the same mass flux. For simplicity the Blasius equation (15,16) can be used. The two-phase pressure drop multiplier can be calculated according to the Friedel correlation: φ O E + 3.4* F * H Fr.45 * We.35 = () TP TP The two-phase heat transfer coefficient can be calculated according to the Kandlikar correlation. C C C α = α *( C * Co *(5* Fr ) 5 + C * Bo 4 * F ) (6) TP O 1 O 3 fl α O is the heat transfer of the of single phase liquid with the same mass flux. For simplicity the Dittus-Boelter equation (7) can be used. With the above mentioned formulas a possible cooling pipe solution for the upgrade of the Atlas staves (see next section for details) was analysed to give an estimate of achievable tube diameters. An indication of the temperature distribution over the tube for the estimated tube diameter is also given. C. Example cooling tube of an Atlas upgradestave. To demonstrate the superior properties of CO with respect to and C F 6, the cooling of a possible Atlas upgrade stave is analysed for all three fluids. The stave is constructed of two layers of silicon, each layer existing of wafers with a spacing of 1cm. Each wafer assembly dissipates 17 watt. The four meter long cooling tube runs along all wafers and has to absorb a total power of 68 Watt. Cooling x wafers à 17 Watt 1 Atlas stave : meter length Figure 3: Schematic example of an upgrade Atlas stave The estimated cooling fluid temperature for this calculation is -35 C and the outlet vapor quality is fixed at 75%. First the pressure drop as a function of the tube diameter is calculated using the pressure drop formula of equation 1. Figure 4 show the pressure drop dependency as a function of the diameter for the three fluids. Figure 5 shows the temperature drop along the tube as a function of diameter. This temperature drop is a result of the changing saturation pressure (temperature drop phenomena explained in figure ). sure Pressure Drop (bar) Drop (bar) - -.5-1 - -1.5 - - -.5 C F 6 CO -3 5 3 4 5 6 7 8 9 1 3 4 5 6 7 8 9 1 Hydraulic Diameter (mm) Figure 4: Pressure drop of CO, and C F 6 as a function of tube diameter 39

- Temperature Drop (ºC) -1 - -3-4 -5-6 CO C F 6 T=- C Temperature( C) -4-6 -8-3 -3 CO 7.7 C F 6 5mm HX length 75mm HX length -7 3 4 5 6 7 8 9 1 Hydraulic Diameter (mm) CO = C F 6 = =.7mm 4.3mm 7.7mm Figure 5: Temperature drop of CO, and C F 6 as a function of tube diameter For a given diameter, the pressure drop of CO is the lowest of the 3, this is due to the high latent heat of CO (less flow=less pressure drop), the low viscosity and the low vapor speed. Table 1 shows the calculated mass flows for the thee fluids at -35 C, 75% exit vapor quality, and 68 Watt. If we assume a maximum temperature gradient over the tube of C we can extract the necessary tube diameters from figure 5. Table 1 shows the tube diameter selection and the corresponding mass flux. Table 1: Required mass flows, fluxes and diameter Fluid Mass flow ( g / s ) Tube diameter (mm) CO.9.7 56 C F 6 9.6 4.3 186 8.7 7.7 661 Mass flux ( kg /m s) After selecting the necessary tube diameter the heat transfer to the tube can be calculated. For comparison the heat transfer is calculated over a length of 75mm and 5mm respectively. The heat transfer coefficient is calculated using the Kandlikar correlation as given in equation 3. The fluid dependent parameter F fl is set to 1 for all three fluids assuming stainless steel pipes, as suggested by Kandlikar []. Figure 6 shows the calculated heat transfer coefficients. Figure 7 shows the temperature distribution over the cooling tube length for the cooling fluid and the tube wall for both heat exchange lengths. The presented calculation clearly shows the superior behaviour of CO as evaporative cooling fluid for detector applications. A CO evaporator needs the smallest diameter tube and has the best heat transfer coefficients of the three fluids. Heat Transfer Coefficient (W/mK) 15 1 5 CO Heat exchange length 5mm C F 6 75mm.5 1 1.5.5 3 3.5 4 Tube ength (m) D.7mm x 5mm = 8167 W/m D4.3mm x 5mm = 5337 W/m D.7mm x 75mm = 67 W/m D4.3mm x 75mm = 16779 W/m D7.7mm x 5mm = 811 W/m D7.7mm x 75mm = 937 W/m -34-36.5 1 1.5.5 3 3.5 4 Tube length (m) Figure 7: Cooling tube temperature distribution. D. Cooling cycle After defining a proper two-phase flow in the evaporator tube it is important to select a method to get this two-phase condition in there. In general there are two methods to achieve this. One is a liquid pumped system with an external cold source; the second method is to use the evaporator tube directly in a refrigeration cycle. Both methods have been used at CERN for the HC experiments. The Atlas inner detector uses a vapor compression system with as refrigerant [3], The HCb-VEO Thermal Control System (VTCS) [4,5] uses a liquid pumped system using the two-phase Accumulator Controlled oop (PAC) method [6] with CO as working fluid. Traditional method: Vapor compression system Cooling plant PAC method: Compressor Chiller (Atlas) Compressor (HCb) BP. Regulator Pump iquid circulation Cooling plant Warm transfer Cold transfer Heater Detector Pumped liquid system Detector Pressure Pressure iquid iquid -phase Enthalpy -phase Enthalpy Vapor Vapor Figure 8: Two-phase cooling system principles used at CERN. The advantage of the Atlas system is that one can use warm transport lines; a pumped system has cold transfer lines and needs proper insulation. The insulation layer gives extra space requirements, however the tubes are smaller so the mass involved is most likely lower. The disadvantages of the Atlas system are the existence of heaters in the detector to boil-off the remaining liquid, an oil-free compressor is needed as well which is in general harder to find as an oil-free pump. The main advantage of the VTCS-PAC method is a complete passive evaporator section inside the detector. Neither actuators, nor crucial sensors are needed in the inaccessible detector area. Figure 6: Heat transfer coefficients. 33

II. THE PAC METHOD So far two CO cooling systems have been developed for particle physics applications. CO was proposed as alternative cooling fluid for the HCb-VEO in 1998 [7]. The positive results of the feasibility tests for the HCb-VEO with CO, has inspired the design of Tracker Thermal Control System (TTCS) [8] of the Alpha Magnetic Spectrometer (AMS) for the International Space Station (ISS) [9] to use CO as well. The AMS-TTCS is a mechanically pumped two-phase loop system where the CO vapor is condensed to a cold radiator plate. The evaporator pressure is controlled by a two-phase accumulator which is the regular way of controlling the pressure in a capillary pumped loop. The capillary pumped loop is an evaporative heat transport system where the flow is achieved by capillary pumping. Capillary pumped loops are applied in satellite cooling [1]. The development of a twophase accumulator in combination with a mechanical pump in the AMS-TTCS, has inspired the design of the HCb-VEO cooling system. The use of a two-phase accumulator as loop pressure control was named PAC method, which stands for two-phase Accumulator Controlled oop. Heat out Heat in -Phase Accumulator Heat out Condenser P 7 5 P 4-5 1 Pump 6 ong distance 3 Heat exchanger Figure 9: The PAC principle 4 Restrictor Heat in evaporator The accumulator vessel is mounted in parallel to the system and contains by design always a mixture of liquid and vapor. This guaranteed presence of a saturated mixture makes the loop pressure to be a function of the accumulator temperature. The PAC method works as long as the chiller is able to keep the CO outlet of the condenser colder than the accumulator saturation temperature. In this way the pump is fed with sub-cooled liquid and can run free of cavitation. The internal heat exchanger is heating the sub-cooling, so that the evaporator is always evaporating at the saturation temperature set in the accumulator. Between node and 3 heat is applied via the internal heat exchanger to reduce sub-cooling. iquid expansion takes place between node 3 and 4, ending up with saturated liquid at the evaporator inlet. The evaporator is taking up heat from node 4 to 5, where the vapor quality increases due to evaporation. The evaporator outlet (node 5) can still be partly liquid, not all the liquid need to be evaporated as the pump is providing an overflow. The heat exchanged from node 5 to 6 is equal to the heat applied to node to 3. In the fact of insufficient heat absorption in the evaporator or from the environment, node 6 can be sub-cooled. In this case there is still evaporation in the evaporator but only sub-cooled liquid is present in the condenser. Only at extreme unbalance between the subcooling temperature and the evaporator saturation temperature, there is sub-cooled liquid in the evaporator. The PAC is now out of its working range. The condenser is the section from node 6 to 1, with sub-cooled liquid supplied back to the pump again at node 1. Nodes 4, 5, 6 and 1 all have the same pressure as the accumulator, neglecting the small pressure drop in the system. III. THE HCB VEO DETECTOR The HCb-VEO [1] is the sub-detector closest to the collision point in HCb. It consists of 1 double and single silicon sensor layers which are positioned at about 1 cm distance from the HC proton beams. The VEO is split into two halves both covering half of the active silicon sensor area. The silicon wafers are mounted on a module containing the read out electronics and mechanical support. The silicon modules are situated in a vacuum volume which is separated only by a.3mm aluminium foil from the HC beam vacuum volume. The maximum allowed pressure difference between the vacuum volumes is 5 mbar, which is controlled by a complex system for pumping down and filling the vacuum volumes simultaneously [1]. The reason for a secondary vacuum is the out gassing of the silicon modules, and the possibility of installing detector hardware without exposing the HC beam vacuum volume to the air. The.3 mm aluminium foil around the silicon modules acts also as a Faraday cage protecting the silicon and electronics from the electromagnetic interference of the proton beams. Pressure P 7 iquid 3 Vapor -phase 1 4 6 5 Figure 1: The PAC cycle in the Pressureenthalpy diagram Enthalpy Figure 1 shows the operation of the PAC in the pressure-enthalpy diagram. The nodes in the diagram correspond to the locations in the schematic of figure 9. Node 1 in the liquid zone is the pump inlet, node the pump outlet. Figure 11: The HCb-VEO detector with a quarter of the silicon modules visible. The silicon sensors suffer from a high dose of radiation induced by the HC proton beams. The radiation causes damage to the silicon crystal lattice resulting in an increase of 331

depletion voltage. Permanent cooling of the sensors is needed to avoid further degradation of the silicon sensors. A silicon temperature less than -7ºC is sufficient to minimize the effects of radiation damage. Secondary Vacuum Figure 1: Cross section of the VEO detector A. VEO module design. HC Beam Vacuum Silicon CO cooling The VEO modules consist of a carbon fiber TPG laminate where on both sides an electronics hybrid with a silicon sensor is glued. At the bottom of this laminate the CO cooling evaporator is mounted on one side and the carbon fiber support paddle on the other side. The paddles are mounted on a stiff aluminium base frame. Figure 13 shows a picture of an assembled VEO half with the discussed items clearly visible. The Beetle read-out chips are located on the hybrid at the edge of the silicon and can generate up to 8 watts of heat per module which needs to be taken away by the CO cooling system. The aluminium base is the positional reference of the modules and must stay at room temperature. This is achieved by heaters since the thermal connection via the paddles to the CO evaporators will otherwise cause the base to cool down. B. CO evaporator design. Each silicon module is connected to a dedicated parallel evaporator branch. Each branch consists of a 1 meter long stainless steel capillary of 1.5x.5mm, which is embedded in an aluminium cooling block which is attached to the carbon fiber/tpg laminate. The aluminium cooling block is obtained with a casting procedure specially developed at Nikhef. The Aluminium is melted around the tube in a vacuum oven, so that the Al joins the stainless steel in a chemical way. The casting will give a lot of freedom in pipe geometry inside the aluminium and a perfect thermal contact between the pipe and the cooling block. Each evaporator branch has a 1.3 meter restriction capillary of 1x. mm at the inlet to obtain a good flow distribution over all the evaporator branches. The presence of the evaporator in a vacuum system gives high constraints to the leak tightness. Therefore the complete evaporator assembly (figure 14) is made of stainless steel tubes all joined together with vacuum brazing or orbital welding. No connectors are present inside the vacuum system. The inlet manifold connected to the inlet capillaries is outside the vacuum vessel and is accessible. This way it is possible to connect cooling to individual channels, a feature which is used by module commissioning using a small scale test cooling system. Figure 14: VTCS CO evaporator assembly Figure 13: Assembled VEO half with silicon modules, cooling blocks, and module base IV. THE VEO THERMA CONTRO SYSTEM (VTCS). The VTCS is a cascade of three hydraulic systems. A Freon chiller condenses the CO vapor and rejects the waste heat to the cold water system of CERN. This chiller has a gas compressor, water condenser, evaporators and expansion valves. The water system is called the primary cooling system, the chiller the secondary and the CO loop the tertiary cooling system. Figure 15 shows a schematic diagram of the cascade systems, with the main heat flows and the system temperature distribution. The VTCS also has an air-cooled chiller with lower capacity. This back-up can only cool the CO loops to -1 C and has no capacity left over to absorb detector power. It is only for maintaining the unpowered detector cold to avoid radiation damage in case of a problem or during maintenance. 33

Detector waste heat Tertiary system (CO) Qt1 Qt3 Qt4 Work Control (Pump) heat -4 C Qs1=Qt1+Qt+Qt3+Qt4 Qt Environmental heat leak Qs Secondary system (R44a) (R44a) R57A Qs3 Qs4 Qp1=Qs1+Qs+Qs3+Qs4 Environmental heat leak [13]. This temperature can be set in the system by controlling the accumulator pressure and hence saturation temperature. This temperature setting of the accumulator is called the VTCS set-point. For commissioning the set-point can be set higher, as the silicon sensors are not yet irradiated. Under vacuum the cooling temperature for commissioning is -5 C, for commissioning under Neon atmosphere the cooling temperature is +1 C. Operating the cooling at +1 C is achieved by using the back-up air-cooled chiller, as the water cooled chiller is to powerful for operation at higher temperatures than -5 C. Primary system (Water) Work & Control heat heat (Compressor) - C C C PC Freon Unit Figure 15: Block diagram and heat balance representation of the VTCS The cooling plant of the VTCS is placed 55 m away from the VEO detector behind a thick concrete shielding wall (See figure 16). This wall shields the system from the radiation of the HC. The VTCS is designed such that all active hardware is located in this safe zone. The cooling hardware in the experimental area consists only of tubes and passive devices such as restrictors and one-way valves. Sensors (pressure and temperature) in the radiation zone are only for monitoring and are not important for the cooling system operation. The CO evaporators in the detector are connected to the VTCS via 55 meter long concentric transfer lines. The liquid feed transfer tube (1/4 x.35 ) is situated inside the vapor return tube (16mm x 1mm). The concentric construction acts as a long counter flow heat exchanger needed for conditioning the evaporator inlet flow to be saturated. CO Unit Figure 17: The VTCS cooling plant in the HCb-cavern 4m thick concrete shielding wall.6 m The cooling system is controlled by a Siemens S7-4 series Programmable ogic Controller (PC). It controls the two independent CO loops and also the water cooled main chiller and air cooled backup chiller. Moreover, the PC handles all the VTCS safety alarms and it interlocks to other subsystems of the VEO like low voltage, bias voltage and vacuum system. In total the cooling system contains about pressure sensors, more than 15 temperature Accessible and a friendly Inaccessible and a sensors and over environment hostile environment actuators such as pumps, valves, compressors and PC heaters. Note that only a fraction of these sensors are crucial for the 3.6 m operation of the cooling system. The other sensors allow us to Evaporators 8 Watt max per study the behaviour of CO PAC s: R57A Chillers: detector half the system in great 1 for each 1 water cooled detail. This is important detector half 1 air cooled Concentric as the VTCS is the first transfer lines CO based cooling system in use at a HEP 55 m experiment. The main VEO control task in the CO loops is to regulate the Figure 16: VTCS set-up in the HCb cavern pressure by either evaporating liquid or by condensing vapor in the accumulator. Stabilisation is achieved by PID loops. The flow in the evaporator must be of low vapor quality to For the freon chillers the most important tasks are the control achieve a stable liquid expansion in the flow distribution of the expansion valves for the CO-freon heat exchangers capillaries. The needed evaporator temperature to achieve the and the frequency of the compressor. silicon temperature requirement is between -5ºC and -3 C 333

3 5 15 1 5 S tart-u p Pump Outlet Temperature (TRTT1pvss) Accumultor Accumulator saturation saturation temperature (Set-point) (TRPT1tsat) = Setpoint C-Side Condenser Out- / Pump RF-Foil temperature outlet Inlet (TRTT43pvss) / Pump Temperature sub cooling (TRTT11pvss) TR Evaporator Temperature temperature (TRTT48pvss) C-Side Pump Pump Module Outlet Base outlet Temperature (TRTT1pvss) (TRTT38pvss) Condenser Inlet (TRTT11pvss) inlet C-Side RF-foil RF-Foil temperature (TRTT43pvss) Condenser Out- / Pump Inlet Temperature (TRTT11pvss) S p = ºC S p= º C Measured Temperature (ºC) -5-1 -15 - S p = -1ºC Sp = -ºC S p = -5º C Sp = -3 ºC -5-3 S p= -3ºC -35-4 -45-5 1 15 5 3 35 4 45 5 55 6 65 7 Time from 9 March clock time (Hours) D a ys + 6 hou rs co oling u nde r vacu um at several se t po in t te m pe rature s Figure 18: Unpowered detector cooling tests under vacuum in March 8. V. COMMISSIONING RESUTS OF THE VTCS. The VTCS was installed in 7 and commissioning was started early 8. The full detector was not operational until May 8. Prior to detector availability, dummy heaters were installed near the VEO to replace the detector heat load. The flow through the detector was by-passed, as it was not allowed to cool the detector below 1 C under Neon vented condition of the vacuum volumes. The VTCS was tested using the dummy heaters under several heat loads up to 8 Watt per loop. In March 8 the detector was for the first time cooled under vacuum conditions at several operational temperatures ranging from C to -3 C (See figure 18). There was no power dissipated neither in the detector nor in the dummy heaters. The detector electronics were not yet cabled. In May the detector was powered on module by module under Neon atmosphere with the back-up chiller at 1 C cooling only one detector half. After the successful detector powering tests, the detector was evacuated to vacuum at the end of June for upcoming HC commissioning. Following the evacuation the full detector was commissioned with its designed cooling temperature of -5 C and all the electronics switched on. The start-up of the left VTCS is shown in figure 19. Around 13.4 clock time the accumulator started heating (7,red) to increase the pressure (7,gold) to 7 C saturation temperature. As the loop saturation temperature is higher than the environment temperature, the loop is filled with liquid and consequently the accumulator liquid level is dropping (7,blue). Around 13.6 hour the pump was started as can be seen by the increase of the pump head pressure (). The chiller is started right after this cooling down the liquid flow to the pump (1). After pumping cold liquid for a while, the accumulator is cooled to bring the pressure down to the desired set-point pressure and hence temperature. The accumulator cooling is the negative signal from the combined heating/cooling control (7, red). Due to the accumulator cooling, the accumulator is filling as can be seen by the increasing liquid level (7,blue). Around 14.7 hour the setpoint has been reached and the temperatures and pressures stay constant. The accumulator remains to be cooled to compensate the environmental heat leak from the environment. The VTCS is now ready for detector power. Temperature ( C) Pressure (Bar) evel (%) Cooling/Heating Power (%kw) 7 75 5 5-5 -5-75 -1-7 + 4-7 Accumulator Control: + = Heating - = Cooling _ Pump head pressure (Bar) 7 4-Accumulator liquid level (vol %) 4 7 - Accumulator pressure (Bar) 5 4 Evaporator temperature ( C) 1 Pumped liquid temperature ( C) 13 13.5 14 14.5 15 15.5 Clock time (hour) 7 +7 1 Figure 19: Start-up of the left-vtcs PAC Figure shows the powering-up of the left detector with the cooling set-point to be -5 C. Around 15 minutes the detector is switched on. The purple line is the individual heat load of one module, the blue line the total heat load of the left detector. As a result the module temperature (black line) and the silicon temperature (green line) are increasing. The silicon is stabilizing around -7 C; this is according to the design requirements. The applied heat in the evaporator increases the 4 334

amount of vapour in the system which causes the pressure and hence the evaporator temperature to rise a bit. The accumulator control is reacting to this pressure offset by cooling the accumulator (cyan line). As a result is the liquid level (red line) increases because the generated amount of vapor is accumulated in the accumulator. After a small deviation the evaporator temperature is maintained. Temperature ( C), Power (Watt), evel (vol %) 8 6 4-7 C Accumulator iquid evel (vol %) Acumulator heating/cooling (% kw) Module V11-C power (Watt) Module V11-C cookie temperature ('C) Module V11-C NTC temperature ('C) Module V11-C NTC1 temperature ('C) Detector half heat load (x1) Module Heat load Silicon temperature Accu Heating/Cooling (x1) Accu level SP=-5 C - Evaporator SP=-5 C temperature -4 :3 1: 1:3 : Time (Hour) Figure : Commissioning results of the eft VEO detector cooling. After running stabile with the detector being powered, the set-point temperature was changed to -5 C. Around 5 minutes the accumulator control reacts with heating the accumulator (cyan line) and hence a decreasing liquid level (red line). The temperatures of the evaporator and the module are increasing until the -5 C set-point is reached. The accumulator control stops heating and stabilizes with a small cooling action. Around 1:4, the detector is powered down, and the VTCS is reacting to the opposite way compared to the detector powering up. The accumulator is heated and the liquid level is dropping, because the amount vapour in the loop is decreasing. VI. CONCUSIONS AND OUTOOK. This paper has demonstrated that CO as evaporative coolant is very promising. It has multiple advantages for detector applications as CO seems to add less mass to the detector compared to evaporative cooling with fluor-carbons. The possibility of using smaller tubing is not only beneficial for the mass budget, but gives also more flexibility in the design as the pipes are more flexible. Flexible tubing gives less structural impact on the detector mechanics, such as thermal expansion. The PAC method was presented in this paper. The VTCS was built according to this principle and the VTCS works as expected. The requirements are met, as the silicon was operating at -7 C at the designed cooling temperature of -5 C. The evaporator temperature turned out to be very stable; fluctuations of less than.5 C were measured over time. The VTCS set-point range was determent to be between -5 C and -3 C. The construction of the VTCS is not yet finished. The VTCS commissioning has learned us that an accumulator connection at the inlet of the condenser is working better than the location after the condenser were it is now. The accumulator heating was sometimes giving saturated liquid to the pump, causing the pump to cavitate. The accumulator connection swap will solve this problem. One PAC side (right system) was temporarily modified, and results were promising. It was decided to implement this modification on both PACs. These modifications will be done early 9. Other ongoing works are the implementation of the automatic back-up procedures, the chiller expansion valve tuning and the integration of the system in the PVSS-finite state machine. VII. P = Pressure drop (Bar) NOMENCATURE φ =two-phase pressure drop multiplier E, F, H = Friedel correlation constants α = Heat transfer coeeficient (W/m K) Fr = Froude number We = Weber number Re =Reynolds number Pr = Prandl number Co = Convection number Bo = Boiling number Nu = Nusselt number h = Enthalpy (J/kg) λ = Thermal conductivity (W/mK) ρ = Density (kg/m 3 ) η = Dynamic viscosity (Pa*s) σ = Surface tension (N/m) Cp=Heat capacity (J/kg*K) x= Vapor quality g = Specific gravity (m/s ) ƒ = Friction factor m = Mass flux (kg/m*s ) q = Heat flux (W/m ) D = Hydraulic diameter (m) C 1 = Kandlikar s nucleate boiling constant:.6683 C = Kandlikar s nucleate boiling constant: -. C 3 = Kandlikar s nucleate boiling constant: 158 C 4 = Kandlikar s constant:.7 C 5 = Kandlikar s constant: (Fr O >.4),.3 (Fr O <.4). F fl = Fluid surface parameter: 1 for stainless steel tubes Indices: TP =Two Phase O = iquid only =iquid G =Vapor 335

(1) P = φ * P TP O O VIII. EQUATIONS: E+3.4*F*H () φ O = Fr.45 *We.35 O O ρ *f (3) E=(1-x) +x GO ρ G *f O.78.4 (4) F=x *(1-x).91.19.7 ρ η G η (5) H= * * 1- G ρ G η η (6) C C 5 C α =α *(C *Co *(5*Fr ) +C *Bo 4 TP O 1 O 3 *F fl ) (7) α =Nu*λ /D m (8) Fr= g*d*ρ m *D (9) We= ρ TP *σ m *D (1) Re= η η *Cp (11) Pr= λ.8.5 1-x ρ (1) Co= * G x ρ q International Workshop on Vertex detectors, ake Placid, NY, USA, PoS 9 [6] Verlaat B., 7, Controlling a two-phase CO loop using a two-phase accumulator, International Conference of Refrigeration 7, Beijing, China, ICR7-B-1565 [7] Boer Rookhuizen H. et al, 1999, Preliminary Studies for the HCb Vertex Detector Cooling System, HCb note, 99-46/VEO [8] Verlaat, B., Woering, A., Pauw, A., Delil, A.A.M., 3, AMS- Tracker Thermal Control System: design and thermal modeling of the mechanically pumped twophase CO loop, AIAA Aerospace Sciences Meeting & Exhibit, Reno, NV, USA, AIAA-3-345 [9] Borgia, B, 5, The Alpha Magnetic Spectrometer on the International Space Station, IEEE Transactions on Nuclear Science, Vol. 5, No. 6, p. 786-79 [1] Delil, A.A.M. et al., 1997, In-orbit demonstration of two-phase heat transport technology - TPX II reflight, European Space Agency, SP-4, p.355 [11] HCb Coll., 1, The HCb VEO technical design report, CERN/HCC 1-11 [1] Van Beuzekom M. et al, 8, The HCb VEO Vacuum System User manual, CERN EDMS 91535. [13] Verlaat, B, 5, Thermal performance testing of the VTCS evaporator and VEO module, NIKHEF EN5-1 (13) Bo= ṁ*(h G -h ) (14) Nu=.3*Re.8 *Pr.4. *f *m (15) P = D*ρ.79 (16) f O = 4 ReO IX. REFERENCES [1] Pettersen, J., Rieberer, R., Munkejord, S.T.,, Heat Transfer and Pressure Drop for Flow of Supercritical and Subcritical CO in Microchannel Tubes, Norwegian University of Science and Technology/SINTEF Energy Research, TR A517 [] Kandlikar S et al, 5, Heat Transfer and Fluid Flow in Minichannels and Microchannels,ISBN:-84-457-6 [3] Attree D. et al, 8, The evaporative cooling system for the ATAS inner detector, 8 Jinst 3 P73. [4] Verlaat B. et al, 8, CO cooling for the HCb- VEO experiment AT CERN, 8th IIF/IIR Gustav orentzen Conference on Natural Working Fluids 8, Copenhagen, Denmark, CDP 16-T3-8 [5] M. Van Beuzekom, A. Van ysebetten, B. Verlaat 7, CO cooling experience (HCb), The 16th 336