Wood pellet and biomass system ceramic igniter

Similar documents
Wood pellet and biomass system ceramic igniter

Biomass burner Oxygen sensor Specification Data

Biomass burner O2 Sensor Catalog. FKK Corporation

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Ceiling Mount Temperature Sensor

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

Pyroelectric Infrared Sensors

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

Light oil / kerosene burner

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

INFRARED RADIANT HEATERS

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Light oil - kerosene burner

M7100 Pressure Transducer

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Ionizer (Static Remover) STABLO-EX Instruction Manual

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

ELIMINOSTAT DC-ESR-CL-S2

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

SolderSleeve Insulated Electrical Termination Devices

UV - flame detector dual fuel burners for intermittent burner operations

Specification Document. Color-changing Recovery Type Water Leakage Sensor AD-RS

an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

OPERATION AND MONTAGE MANUAL ROOF FANS

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 15 Page 1 of 7 Publish Date May 13, 2018

Two Circuit Heavy Duty Burner Connector

Compact Ultra Low Temperature Chamber

Forced draught gas burner

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Jan05 Rev A EC

Installation Instructions Part No

Handling Note SHARP COB ZENIGATA LED SERIES

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

OPERATION AND MONTAGE MANUAL ROOF FANS

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

Pyroelectric Infrared Sensors

Installation & Manual. Model T-25

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

Photovoltaic Cables EN H1Z2Z2-K

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

Metal, ceramic, plastic package products

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Aquamax KF Oil Evaporator. User Manual

ZMOTION Pyroelectric Sensors


EMI Filter (Data Line) TRIGON COMPONENTS. Dimensions Table (mm)

Viking Installation Guide

1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

Incinerator Model A1600 -Oil

OPERATING INSTRUCTIONS WPSI12. Portable Soldering Station & TCP12. Soldering Tool. Weller Tech Sheet Product Code: Issue A 24/05/05

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

Reference Specification

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Applications PL- N Series Lens Type Sensor Type Serial Number

Air Paper Jogger AJ-700 Operation Manual. Keep this manual at hand where it can be referenced at any time.

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

CHILLER. Operator s & Installation Manual

C Note! LGI16... Burner Controls. Building Technologies

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

MD-MINI Dry Bath. Instruction Manual

Class 1 laser beam sensor safe for your eyes

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

Dual Column Dehydrating Breather Manual

Sprinkler Identification Numbers

FEATURES ORDERING CODE KED ST D T (1) (2) (3) (4) (5) (6) (7) Transient Voltage Suppressors (ESD Diodes) TRIGON COMPONENTS

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

Manual Power relay SR853

LAARS PENNANT. Economical efficiency for greater savings

June Humidity Sensor. CHS series

Reflector T2 and GU10 6,000 hours

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Cartridge Heaters. Components. Application Guidelines

ELLA ID. High CRI, High lm/w OptoDrive LED-module

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Transcription:

Wood pellet and biomass system ceramic igniter Specification Data Product name: Ceramic Igniter PSx-6-240-B Drawing number: IBA-HH008A Revised on: 2015.12.20

1. Application This engineering specification data applied to ceramic igniter, which is used for the ignition of biomass (especially wood pellet) burning system. It can also be adapted to other specific application (biofuel system, water boiling, industrial oven, etc). 2. Part Number Part number PSx-6-240-B Product type Flange, fitting type Voltage Heating element type PSx: Pellet System X 6: G3/8 brass flange type 240: 240V (220~240V) B: Black heating element type (=300W class) 2

3. Materials Numbers refer to related drawing parts list. 1. Heating element LCR-332C-240VFL Metalized Alumina Al2O3 92% Dimension: 11.55 x 106 L Insulation resistance 40.15~49.13 Ω (at23±1 C) Dissipation pattern: in-line 2. Mounting flange G3/8 brass flange 3. Lead wires Nissei Electric RS-GE 0.5sq White Heat resistance: 180 C 4. Heat shrinkable tube Nissei Electric Silicon heat shrinkable tube Dimension: 4x28L Heat resistance: 180 C Breakdown voltage: minimum 6kV 5. Crimp terminal connector Nippon Electrode Splice 29071-1 Material: Copper, Tin plating 6. Heat shrinkable tube Nissei Electric Silicon heat shrinkable tube Dimension: 16x20L Heat resistance: 180 C Breakdown voltage: minimum 6kV 7. Ceramic compound sealant Fujiceram-W ceramic sealing compound 1 2 7 4 6 3 5 3

4. General properties Properties Value Condition Forward Current AC240V ±10% 50 / 60Hz 345 W (AC240V) Power consumption 315W (AC 230V) 295 W (AC 220V) 44.65Ω Normal temperature resistance Rising time 40.15~49.13Ω > 820 C within 60s, Max temperature of 1000 C after 120s 23±1 C ambient temperature Inrush current > 5.7A Minimum W attage > 295W 23±1 C ambient temperature Minimum temperature Insulation resistance Withstand voltage Caulking strength (Nickel wire and lead wire) Discontinuous conduction (heating element) Test condition: 870 C > 50MΩ Current Leakage 5 ma 29.4 N (over 3kg f) Without break Applied at both side of Heating element DC500V at normal temperature and humidity Applied at both side of Heating element AC 1500V for 1 s at normal temperature and humidity rate The nickel wire has been clamp and the lead part has been tested with push-pull gauge. Applied at 264V for 4min On/5min Off (forced cooling) for over 3000 cycles All values have been measured in the same condition as follow: Temperature: 23±1 C Humidity rate: 25~80% Atmospheric pressure: 101.3kPa~106kPa 4

5. Heater application environmental condition Temperature Characteristics Unit Minimum Normal Maximum Storage Storage temperature C -40 5~35 60 Heating element (1) C -40 800 1000 Operation Brasss flange (2) C -40 200 850 Heating element electrodes (3) C -40 120 250 () number on below diagram Wiring assembly (4) C -40 50 180 (1) (2) (3) (4) Heating Element Brass Flange Wiring assembly Change rate Heating Element Electrode (brazing) Characteristics Unit Minimum Normal Maximum Heater resistance Ω 40.15 44.64 49.13 Heater voltage (AC) V 216 240 264 Inrush current (23±1 C, AC240V) A 4.7 5.03 5.7 Heater current A 1.38 1.45 1.52 Heater wattage W 295 345 400 Heater temperature (power Off) C - - 1000 5

6. Rising temperature (reference only) Rising surface temperature varied according to forward current and nominal resistance. The graphs below show the temperatures according to forward current at the recommended resistance value. These values are for reference only. Amps (A) Temperature C 6 1100 1050 5 1000 4 950 900 3 850 800 2 750 1 700 650 0 600 0 20 40 60 80 100 120 140 160 180 200 Time in sec. Current: AC240V / 60Hz (=specification) Peak current: 5.053A Max temperature: 1045 C Nominal resistance: 41.80Ω Emissivity (ε): 0.8 Temperature measurement point: 21.5mm from the tip Condition: temperature 23.3 C / humidity 54%RH Amps (A) 5 4.5 4 3.5 3 2.5 2 1.5 1 0.5 Temperature C 1050 1000 950 900 850 800 750 700 650 Current: AC216V / 60Hz (specification -10%) Peak current: 4.717A Max temperature: 988 C Nominal resistance: 41.80Ω Emissivity (ε): 0.8 Temperature measurement point: 21.5mm from the tip Condition: temperature 23.3 C / humidity 54%RH 0 600 0 20 40 60 80 100 120 140 160 180 200 Time in sec. Amps (A) 6 5 4 3 2 Temperature C 1200 1100 1000 900 800 Current: AC264V / 60Hz (specification +10%) Peak current: 5.572A Max temperature: 1106 C Nominal resistance: 41.80Ω Emissivity (ε): 0.8 Temperature measurement point: 21.5mm from the tip Condition: temperature 23.3 C / humidity 54%RH 1 700 0 600 0 20 40 60 80 100 120 140 160 180 200 Time in sec. 6

7. Durability test (reference only) Discontinuous conduction (Heating element) Without break and substantial deterioration of properties Applied at 264V for 4 min On / 5 min off (Forced cooling) for over 3,000 cycles. Applied at 240V for 60 Sec ON, 180 Sec OFF for over 100,000 cycles. Condition: temperature 23.3 C / humidity 54%RH, ambient air Values for reference only. 60 sec ON, 180 sec OFF cycle reliability test 2 1.5 Resistance variation in % 1 0.5 0 0 20000 40000 60000 80000 100000 120000 Cycle number Serie 1 MIN. Serie 1 MAX. Serie 1 TYP. Serie 2 MIN. Serie 2 MAX. Serie 2 TYP. 7

8. Requirement of heater installation condition For optimal ignition performance and a long lifetime of the igniter s heating element, please read carefully the following installation requirements and notices. Operating temperature After the installation position is decided, the operating temperature of the heater should be measured and each temperature must be within the recommended range defined in the Heater application environmental condition section of the present document. Recommended design To ensure a good protection of the heater we recommend designing a protection tube as follow: The protection of the heater from breaking should be ensured by a metal tube (iron or stainless steel, tick 2mm recommended). The steel protection tube shall let a distance of minimum 3mm around the ceramic heating element. If not respected this could lead to local overheating or ionization of the interspace between the steel tube and the heating element, leading to damage it or substantially reducing the rating life of the igniter. Please avoid direct contact of the ceramic heating element with the protective tube, or solid fuel or ashes. The heater reach a steady-state temperature of about 950~1050 C. For a long lifespan, forced cooling by air blower is not necessary but you should ensure a sufficient stream (stream flow 4~12m 3 /h) of ambient temperature air to avoid overheating. The air stream and protective tube shape should be considered not to collect ashes and material from solid fuel combustion residues. The heater should not be constantly exposed to fire. This could lead to corrosion of the heating element and shorten the life time. I.D 17.6 mm 30~100 mm from grate * * depend on air stream and burner size Protection tube Special recommendation Air inlet > 5 mm x 4 or > 10 mm x 2 Introducing a cleaning stage in the automatic ignition program of the controller board can optimized the performance and rated life of the igniter. A simple cleaning stage, with for instance, fan blower at high speed for 30 seconds before ignition stages, can ensure that the protective tube and heater always remain clean from ashes and other combustion residues. 8

Installation prohibition Please design your system in order that the heating element of the heater never enters directly in contact with solid fuel or ashes or metal protective tube. If the heating element enters in contact with solid fuel, ashes or metal protective it could damage the heating element. Longer protective tube should be considered to avoid this situation. Heating element too close to solid fuel = risk of contact Protective tube too short Please make sure that the heater don t move in protective tube and not leaned as below figure. Attachment system should be considered to avoid this situation. Heating element in contact with protective tube Heater leaned due to bad thread finish Please make sure to let an interspace of minimum 3mm around the ceramic heating element and the tube. Insufficient interspace around heating element 9

Other installation prohibition You should avoid to install the product in a confined environment without air stream, overheat could damage the heating element. While the power is on, please ensure a sufficient flux of ambient temperature air (stream flow 4~12m 3 /h recommended). Environmental temperature of the heater electrode (brazing portion of the metal heater leads), should be maintain at less than 250 C. Do not install the heater in environment which can gather condensed water or be water or oil splashed. In this condition, crack may happen in the heating element. The heater ceramic heating element and flange should be free from harmful contamination. Harmful contamination (ashes, grease, combustion residues) may cause crack or electrical failure. Do not cool too suddenly the heater. Thermal shock crack may occur in the heating element. We strongly recommend starting the system fan before powering on the heater. The wiring assembly part protected by heat shrinkable tube (cf. (1) below figure) should not be bent over 60 degree angle tensile. The curvature of lead wire part (cf. (2) below figure) must be larger than R20. (1) (2) Large tensile stress of lead wire must not be kept in the operation condition. And after being installed, the lead wire must be free from tensile stress. In order to prevent body injuries or serious damage, you should ensure to design a safety environment to place this product, taking in count a possible failure of this component. 9. Handling precautions and prohibitions The following items may seriously affect the rated life and properties of this product. Do not input inappropriate forward current. Applying a DC current may cause the deterioration of the ion transfer and degradation of resistance or disconnection. Please avoid colliding ceramics pieces each other. Please avoid colliding or giving excessive shock to ceramic part (drop down from more than 30 cm height). This could crush or crack the ceramic heating element and break it while powering on. Do not hold the heater by the wiring side only. This handling may cause to hit the heater ceramic element against the operation desk, the rack, the wall, etc. Then the ceramic may be cracked. Please always handle the products with care. When the heater is installed, the heater should be installed by hand. It is not permitted to tighten or fix the heater by spinning connector or the lead wire only. This action will make a twisted wire, and then it may cause a disconnection or lead wire insulation failure. 10

This product specification data guarantee the whole product as well as the part. Please contact our company for specific usage or conditions. Please inform us if you want to make modification to the product. All modification made to the product occurring after the delivery would be consider as outside the scope of the present specification data and the warranty. 10. Storage The heater should be carried and store in FKK blister case until installation in the burner. If the heaters are stored in FKK package, be careful to handling with care. The heater can get damages by wetting, impact by dropping, stacking or mechanical shock etc. Storage in the below conditions should be avoided: Sea breeze, C12, H2S, NH3, SO2, NOX environment Exposition to direct sunlight Long storage in moist and oily condition or in conditions other than 5~35 C normal storage temperature and 45~85% of normal storage humidity 11. Warranty Default, failure due to a defective design and production may be replace by FKK Corporation without compensation within 2 years from the shipment date. For other defectives, the both company should find a compromise in good faith and good fare to resolve the matter. FKK Corporation is not responsible in the below cases: Non observance of data sheet installation requirement Inappropriate use and handling Damage caused during the delivery Repair and modification made by other company than FKK Corporation Damaged caused during natural disaster, fire, etc. In case of defective product, please advise with your FKK sales representative or distributor. In case of replacement of defective products FKK sales representative or distributor will ask you the related product s invoice and serial number (cf. section below). 11

12. Serial number marking All products are marked with a serial number representing the year and month of production. Serial number, Ex: 16 F The last two digits of year 13. Conformity with EC regulation Month Alphabetical order: January~A Februray~B December~L This product complies with European community regulations as follow: 1907/2006/EC 2011/65/EU 2006/95/EC European Directive of June 2006 on Registration, Evaluation, Authorization and Restriction of Chemicals in Electrical and Electronic Equipment (REACH). European Directive of June 2011 on Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS). European Directive of December 2006 on electrical equipment designed for use within certain voltage limits (LVD). *Related Standard : EN60335-1-45, EN60335-2-45 This product have been checked and certified fully compliant to EC regulation by TUV Rheinland certification company (test report No:50031010001 and 0144065711a001) 12

14. Revision history Specification sheet number Customer company name Specification sheet number Revised date Page number Drawing number Designated product Content of revision Item name Content IBA-HH008A PSx-6-240-B Author 13/11/10 all all Creation M.S 13/12/01 all all Complete revision and addition of multiple content M.S 14/03/15 all all Complete revision M.S 14/08/10 all all 15/12/20 all all Complete revision and addition of multiple content Complete revision and addition of multiple content M.S M.S 15. Information For use beyond typical operating conditions or applications, please consult your FKK sales representative or distributor for further information. The products digital data-sheet and drawing can be downloaded on FKK web site or by scanning the QR code below. Data-sheet Drawing 13

About FKK FKK Corporation (Fuji Kogyo Kabushiki) was incorporated in 1954 and since then producing ignition components for gas, oil and biomass sector. The company complies with ISO 9001 and ISO 14001. For more information about FKK and our products, please visit www.plug.fkk-corporation.com 2016 FKK Corporation. All right reserved. 14