INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Similar documents
INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

OUTLET HOT INLET COLD INLET INSTALLATION

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

TA-300, TA-300-LF, TA-350, TA-350-LF

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

MEGATRON MODEL 2, 3, 4, and 5

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

OUTLET LEONARDH THERMOSTATIC INSTALLATION

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

HOT INLET COLD INLET INSTALLATION

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

OUTLET LEONARD THERMOSTATIC INSTALLATION

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

MEGATRON MODEL TA, TA-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

MODEL 210, 210-LF THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING INSTRUCTIONS

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Installation Manual. Models 99168, 99169, 99170

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

INSTALLATION & TESTING MANUAL

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

INSTALLATION, OPERATION AND MAINTENANCE

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

INSTALLATION & TESTING MANUAL

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Nachi Series TM Z6957-XL

Installation Instructions PP-AS20 Anti-Scale System

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

Installation S

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

Installation S

Installation S

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

Whole House Filter Model: WH-LD

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

TUB AND SHOWER FAUCET

INSTRUCTION MANUAL HS-229G

Installation Instructions / Warranty

Model TWBS.EW.H Tempered Water Blending System

CLASSIC HIGH LOW MANIFOLD SYSTEMS

Installation Instructions

AeroVent 3X Product Manual

Instruction Manual. Nacho Cheese Dispenser and Warmer

Installation & Operation Manual

Installation Instructions / Warranty. PuraVida 15775XX1

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Installation S

Installation, Operation, and Maintenance Manual

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

AeroVent 1 Product Manual

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Instruction Manual. Carmel Apple-Dip Warmer

Installation Instructions / Warranty. Massaud

Installation S

TORRID MARINE YACHT QUALITY Since Owner s Manual

Model 9201EFE Tempered Water Blending System

INSTALLATION INSTRUCTIONS WARRANTY

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Transcription:

Bulletin 82 August, 208 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES, -LF,, -LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!!! WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer. For more information, go to www.p6warnings.ca.gov INSTALLATION. Valve should be installed at a location where it can easily be cleaned, adjusted or repaired. 2. The inlets are clearly marked on the valve body. Union angle strainer checkstops furnished must be installed on both supply lines as shown above. 3. A shutoff valve must be installed on the outlet pipe. Type XL valves do not have a built-in shutoff. 4. Use solder, or thread sealant sparingly. Supply pipes should be flushed before the valve is connected. Flush outlet pipe and valve as soon as it is connected. 2 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE CAUTION All thermostatic water-mixing valves have limitations. They will not provide the desired accuracy outside of their flow capacity range. Consult the flow capacity chart on page. Minimum flow must be no less than as shown. REMEMBER! THIS IS A CONTROL SYSTEM WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANCE GUIDE AND RECORD MGR-000). 360 Elmwood Avenue, Cranston, RI 0290 USA Phone: 40.46.200 Fax: 40.94.30 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com

INSTALLATION REQUIRED METHODS OF PIPING XL SERIES METHOD # Required when TEMPERED WATER is NOT CIRCULATED. Only the hot water supply to the mixing valve can be circulated with this piping arrangement. FIXTURES, SUPPLIED BY TEMPERED WATER THERMOMETER T HOT WATER SUPPLY COLD WATER SUPPLY METHOD W CIRCULATE HOT WATER FROM END OF LINE BACK TO TANK Required when TEMPERED WATER IS CIRCULATED. FIXTURES, SUPPLIED BY TEMPERED WATER THERMOMETER T C CIRCULATOR A HEAT TRAP AQUASTAT HOT WATER SOURCE COLD SUPPLY BALANCE VALVE OPERATION. Verify that the temperature of the hot water source is properly set and maintained. Shutoff and isolate the circulator pump. 2. Loosen LTR set screw located on temperature adjustment knob with allen wrench. 3. Turn on enough fixtures to flow approximately GPM, turn knob clockwise until it stops (full cold) then counterclockwise until it stops (full hot), three times to exercise the thermostatic element. 4. Set mixing valve to the desired temperature, (See warning tag for temperature set point). Tighten LTR set screw.. Shut off all fixtures. Setup is complete. 6. Turn on circulator. With all fixtures still off, (no water flowing) observe the circulation temperature until it stabilizes. 7. If temperature rises, close balance valve until desired temperature is reached 2

INSTALLATION CONTINUED WARNING WARNING! This Thermostatic Mixing Valve has an Locking Temperature Regulator (LTR) which must be checked. If the temperature is too high, the installer MUST RESET this adjustment immediately. Always check the temperature of the mixed water after installation. Excessively hot water is DANGEROUS AND MAY CAUSE SCALDING! The LTR is factory set at approximately 20 F (49 C) with an incoming hot water supply temperature of 0 F (6 C) If the incoming hot water supply for your installation is higher than 0 F (6 C), the valve may deliver water in excess of 20 F (49) and the LTR MUST BE RESET BY THE INSALLER. SERVICE Leonard Type XL Thermostatic Water Mixing Valves are simple in design and may be easily cleaned, adjusted and repaired. If the installation is accessible, servicing may be completed without disconnecting the valve. NOTE: Thermostatic Water Mixing Valves are REGULATING mechanisms, which must be regularly maintained to provide best performance. Frequency of cleaning depends on quality of local water conditions and usage. (See Maintenance Guide and Record MGR-000). TROUBLESHOOTING INSTRUCTIONS ITEM: PROBLEM: RECOMMENDED REPAIR KITS: RECOMMENDED REPAIR KITS: PACKINGS & GASKETS. Leak at stem. 2. Leak between valve cover and base KIT /XL32 KIT /XL82 SHUTTLE ASSEMBLY 3. Valve delivers either all hot or all cold water, or will not mix consistently. KIT R/XL32 KIT R/XL82 CHECKSTOPS 4. Hot water bypass into cold line.. Supplies cannot be shut off completely. 6. Leak at checkstop bonnet. KIT 2/0 KIT 2/0 REMEMBER! THIS IS A CONTROL DEVICE WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS. (SEE MAINTENANCE GUIDE AND RECORD, MGR-000). 3

9 0 KIT # KIT # TYPE KIT INCLUDES KIT R/XL32 KIT R/XL82 REPAIR KIT -7 KIT /XL32 KIT /XL82 O-RING 2,3,6,7 KIT 2/0 KIT 2/0 CHECK -6 NOTE: DO NOT REMOVE 8 SNAP RING ON STEM 7 8 6 6 7 4 KIT R/XL32 KIT R/XL82 2 3 4 3 2 9 20 2 ITEM # DESCRIPTION QTY. PART # / KIT # PART # / KIT # SPRING, RETURN KIT R/XL32 KIT R/XL82 2 O'RING, LOWER SHUTTLE KIT /XL32, KIT R/XL32 KIT /XL82, KIT R/XL82 3 O'RING, UPPER SHUTTLE KIT /XL32, KIT R/XL32 KIT /XL82, KIT R/XL82 4 SHUTTLE ASSEMBLY KIT R/XL32 KIT R/XL82 RETAINING RING, COVER 74, KIT R/XL32 76, KIT R/XL82 6 O'RING, COVER KIT /XL32, KIT R/XL32 KIT /XL82, KIT R/XL82 7 O'RING, STEM KIT /XL32, KIT R/XL32 KIT /XL82, KIT R/XL82 8 STEM ASSEMBLY (DO NOT REMOVE SNAP RING) 74900 76900 9 COVER 740 7604 0 KNOB ASSEMBLY 764000 764000 PACKING, STRAINER CAP 2 04, KIT 2/0 04, KIT 2/0 2 SCREEN 2 03, KIT 2/0 03, KIT 2/0 3 LOWER STEM & PACKING 2 03, KIT 2/0 03, KIT 2/0 4 SPRING,CHECK 2 0, KIT 2/0 0, KIT 2/0 PACKING, BONNET 2 0, KIT 2/0 0, KIT 2/0 6 O'RING, UPPER STEM 2 MU-A, KIT 2/0 MU-A, KIT 2/0 7 STEM, UPPER CHECK 2 MU-4A MU-4A 8 BONNET 2 2 2 9 STRAINER CAP 2 6 6 20 SWIVEL 2 74-04- 04/0 2 SWIVEL NUT 2 09/0 09/0 4

FLOW CAPACITIES VALVE MIN FLOW 3.8 3.8 0.3 42 9 72 PRESSURE DROP 0 20 2 30 0.7.4.7 2. 6 20 22 24 26 6 76 83 9 98 28 34 39 43 48 06 29 48 63 82 3 2.4 28 06 93 40 2.8 30 4 208 4 3. 32 2 8 29 0 3.4 33 2 6 23 PSI BAR GPM l/min GPM l/min FLOW RATE GPM (l/min) 6 (246) 60 (227) (208) 0 (89) 4 (70) 40 () 3 (32) 30 (4) 2 (9) 20 (76) (7) 0 (38) (9) 0 20 2 30 3 40 4 0 (0.3) (0.7) (.0) (.4) (.7) (2.) (2.4) (2.8) (3.) (3.4) (3.8) PRESSURE DROP PSI(BAR) LIMITED WARRANTY Leonard Valve Company warrants the original purchaser that products manufactured by them (not by others) will be free from defects in materials and workmanship under normal conditions of use, when properly installed and maintained in accordance with Leonard Valve Company's instructions, for a period of one year from date of shipment. During this period the Leonard Valve Company will at its option repair or replace any product, or part thereof, which shall be returned, freight prepaid, to the Leonard factory and determined by Leonard to be defective in materials or workmanship. There are no warranties, express or implied, which extend beyond the description contained herein. There are no implied warranties of merchantability or of fitness for a particular purpose. In no event will Leonard be liable for labor or incidental or consequential damages. Any alteration or improper installation or use of the product will void this limited warranty. 208 Leonard Valve Company Printed in USA 360 Elmwood Avenue, Cranston, RI 0290 USA Phone: 40.46.200 Fax: 40.94.30 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com