Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

Similar documents
SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

for fresher air Air Handling AIR VENT TECHNOLOGY Units DIRECT DRIVE - BELT DRIVE - CUSTOM BUILT Certificate No: GB9455

ENERGY RECOVERY VENTILATION (ERV)

Lo-Carbon Sentinel Kinetic Horizontal

KOMFORT EC DB Suspended heat recovery air handling units

Sentinel Demand Energy Recovery Ventilation

Air Handling Units. direct drive - belt drive - custom built

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

CI/SfB (57.7) 2nd edition

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS.

for fresher air Air Handling AIR VENT TECHNOLOGY Units DIRECT DRIVE - BELT DRIVE - CUSTOM BUILT Certificate No: GB9455

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Technical Data Ducted Three Phase Split System Air Conditioner

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

ROOFMASTER STEF-HT ROOF FAN

Small Room Heat Recovery Ventilation

Condensing Units CUS 15-60

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

EHH SERIES DRAW THROUGH FAN COILS CFM

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS.

Domestic & Commercial Fans

SMOKE CONTROL - NEW DIRECTIONS

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year.

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Novenco Air Handling Units. Climaster ZCP June 2005

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

The new Xcell EC High Efficiency Range Fresh air pure and simple

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Panther Fan Coil Unit

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Heat Recovery Unit HERU. web-version

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

Bruksanvisning Directions for use

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

Centeral Station Air Handling Unit

Caice Attenuator Selector - Specifier Edition

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Product Specifications. Vertical Floor Consoles By First Co.

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

Mini fans MiniVent M1/100

TopMaster Air Handling unit. Technical data

Hazardous Area Portable Fan Heater The Bulldog

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Centrifugal air heaters hot water or electrical supply

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

The World of. Standard and Special Air Handling Units for Ventilation and Air Conditioning Applications

LOW STATIC HYDRONIC DUCTED UNIT

POWERPLUS SPP Product Brochure

... DF / IDF Gas fired combined heating and ventilation ...

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

DF-IDF air handling units

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Air to Air Heat Exchanger

Series VENTS VUT R WH ЕС

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Lo-Carbon Sentinel Kinetic Range Overview

VEX250H with rotary heat exchanger and EXact control system

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

EC Motor Fan Coil Units. IMD-Y Series l/s

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

BATHROOM EXTRACT FANS SILENT-100 Series

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Lo-Carbon Sentinel Kinetic Range Overview

Hazardous Area Portable Fan Heater The Bulldog

The Sentinel Kinetic Horizontal Range

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

ATC Heating Devices. P. 1 ATC Heating Devices

Transcription:

VMD Range Features & Benefits Performance range up to.4m /s Motor Insulation Class F Anodised aluminium pentapost frame Double skinned panels Compact direct drive units Electric heater battery Built-in fan and heating controls Minimal site installation time Year Guarantee Features The Mini Viking packaged small air handling units have been developed using feedback from installers through to the end user and benefit from tried and tested components; e.g. double skinned construction with plastisol outer panel, mineral wool insulation and galvanised steel inner panel. This construction offers weather resistance and long life with a good thermal and acoustic performance. The materials can also be recycled. Specification Energy Considerations Mini Viking Air Handling Units are designed with savings on potential energy consumption being a prime consideration. Low air resistance components are incorporated as standard, with high efficiency motors also available. Construction Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position. Double inlet, forward curved centrifugal fans provide the lowest noise levels with sufficient performance for ducted systems. Impellers and motor impeller assemblies are dynamically balanced to minimise vibration. Motors are further resiliently mounted. The motors in VMDL, VMDM, VMDL, VMDM & VMDL are conventionally mounted permanent capacitor type with sealed for life ball bearings. Protection is IP44 with Class F insulation ( ambient max.). VMDH, VMDH and VMDH units have smooth and powerful outer rotor type motors. Note: all these direct driven fan/motor assemblies respond best to step transformer type speed control. This type of controller will maximise the service life of the motor. Filters Standard filters are EU4 pleated paper type 00mm deep. These have an efficiency equivalent to a standard grade bag filter and a better dust holding capacity than a fibre or foam filter. Special high grade bag filters can be supplied but they require an additional housing. Electric Coils Electric heaters are sheathed tube type with low surface loading for long life. They include a manual reset high temperature cut-out and are mounted at the fan discharge to protect filters and motors from excess heat. Fan and heating controls are built in and wired internally, reducing site installation time to a minimum. A standard customer interface terminal box is common to all units and provides for various external remote items such as supply fan speed control, time clock, set point adjustment, PIR sensor and room or duct sensor. A power isolator is also provided. Outputs for extract fan (starter built-in), shut off damper and signal input from a fire alarm are also provided. N.B. An additional relay PCB will be required for use with an air quality sensor. Electric heater temperature control is by thyristor. This method enables the sensor to be mounted down stream of the heater in the supply airflow and can hold +/-ºC of the chosen setpoint. A 0-0V cooling output signal is also available which can be used as above. Inlet damper and motor come complete with weatherproof motor cover, needing only wiring into main terminal box. Model Range Spanning a duty envelope of 0.m /s to.4m /s, Mini Viking air handling units are available in eight direct drive. Standard units comprise of direct drive fan, filter, electric heater battery and built-in pre-wired controls. 4 T: 0844 856 0590

Air Handling KEY ELECTRICAL ARRANGEMENT FOR FAN & HEATER (40V) Phase Fan / (40V) Phase Heater (40V) Phase Fan / (45V) Phase Heater (45V) Phase Fan / (45V) Phase Heater Direct Drive Supply Air Handling Units Quick Selection Chart External Duct Resistance ~ Pa 75 00 5 75 0 00 400 0 0. VMDL VMDL VMDL VMDL VMDL VMDM VMDM 0.5 VMDL VMDL VMDL VMDL VMDM VMDM VMDM VMDH 0. VMDL VMDL VMDL VMDM VMDM VMDM VMDH 0.5 VMDL VMDM VMDM VMDM VMDM VMDM VMDH 0. VMDM VMDM VMDM VMDM VMDM VMDH VMDM 0.5 VMDM VMDM VMDM VMDH VMDH VMDH VMDH VMDH VMDH VMDL VMDL VMDL VMDM VMDH VMDH VMDH VMDH VMDH VMDM VMDM VMDH VMDL VMDL VMDL VMDL 5 VMDL VMDL VMDL VMDM VMDM VMDM VMDM VMDM VMDM VMDM VMDH 0.5 VMDL VMDM VMDL VMDM VMDM VMDM VMDM VMDM VMDM VMDH 0.55 VMDM VMDM VMDM VMDM VMDM VMDM VMDM VMDH 0.6 VMDM VMDM VMDM VMDM VMDM VMDM VMDH VMDH 0.65 VMDM VMDM VMDM VMDM VMDM VMDH 0.7 VMDM VMDM VMDM VMDH VMDH 0.75 VMDH VMDH VMDH 0.8 0.85 0.9.0 VMDL VMDH VMDL VMDH VMDL VMDH VMDL VMDL VMDL VMDL VMDH VMDH VMDH VMDH VMDL VMDL VMDL VMDL VMDL VMDL VMDL VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDL VMDL VMDL VMDL VMDL VMDL VMDH VMDH VMDH VMDH VMDH VMDH VMDL VMDL VMDL VMDL VMDL VMDL VMDH VMDH VMDH VMDH VMDH VMDH VMDL VMDL VMDL VMDL VMDL VMDL VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH. VMDL VMDL VMDL VMDL VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH. VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH. VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH.4 VMDH VMDH VMDH VMDH VMDH VMDH VMDH VMDH Model Heater Heater Max. Amps Duty (Kw) Phase (ph) Built in Controller (Total) VMDL or 4.5 TC5t Thyristor (kw) 4A, (4.5kW) A VMDM 6 or 9 TC9 Thyristor (6kW) 7A, (9kW) 40A VMDH 9 or.5 TC Thyristor (9kW) 5A/ph, (.5kW) A/ph VMDL, 6 or 9 TC9 Thyristor (kw) 5A, (6kW) 7A, (9kW) 40A VMDM 9 or.5 TC Thyristor (9kW) 5A/ph, (.5kW) A/ph VMDH 5, 8, or.5 TC Thyristor + Solid State Relay (5kW) 5A/ph, (8kW) 9A/ph, (.5kW) 5A/ph VMDL 8 or 7 TH8 Thyristor (8kW) 8A/ph, (7kW) 40A/ph VMDH 7 or 6 TH6 Thyristor (7kW) 4A/ph, (6kW) 55A/ph W: www.vent-axia.com/ahu 4

VMD Mini Viking Range Sound power levels dbw re 0 W (at full speed) The dba quoted is the mean A weighted sound pressure level measured at a distance of m with spherical sound level propagation. It is included for comparative purposes only and the mean sound level experienced will depend on the area being served. Fan Data Speed FLC Output Octave band mid frequency Hz dba Stock Ref (rpm) (A) (Watts) 6 Hz 5 0 K K 4 K 8 K @ m VMDL 8.0 75 5 5 44 4 9 5 7 40 VMDM 00.5 78 77 69 68 64 59 5 44 46 VMDH 80.0 00 79 80 7 70 66 6 56 47 48 VMDL 900.0 75 7 69 66 64 58 5 4 54 VMDM 00.5 70 78 75 7 69 67 6 55 45 56 VMDH 80.6 5 79 80 74 7 69 64 57 48 57 VMDL 900 6.5 7 77 80 78 77 75 7 67 56 66 VMDH* 40 4./ph 000 77 80 78 77 75 7 67 56 66 VMDH5* 400 4./ph 0 80 8 8 80 78 74 70 59 68 Silencer insertion loss (subtract from sound power levels) To Suit Duct Dims. (mm) Stock Ref Stock Ref W H L 6 Hz 5 0 K K 4 K 8 K VMA5 VMD 0 00 0 4 6 0 8 8 9 VMA54 VMD 0 400 900 5 9 6 0 9 9 6 VMA75 VMD 7 0 0 6 40 5 5 4 9 Sound breakout from unit Stock Ref 6 Hz 5 0 K K 4 K 8 K VMDM 69 6 49 4 44 9 5 VMDM 75 67 54 48 48 5 8 VMDL 76 68 56 5 6 9 4 T: 0844 856 0590

Air Handling Dimensions (mm) - Standard fan, filter electric heater unit A C E F 5 (TYP) B D Unit Size A B C D E F Weight (kg) VMD 7 400 0 00 7 44 VMD 7 0 0 400 5 000 75 VMD 965 700 700 0 0 70 W: www.vent-axia.com/ahu 4

VMD Mini Viking Range VMD Supply Air Handling Unit - Selection Example Component resistance 80 70 A B D Pa 40 0 C 0 0. 0.5 0.6 0.7 0.8 m /s 0.56 VMD Supply Air Handling Unit - Selection Graphs Component resistance 40 Pa 0 0 0. 0. 0. m /s 4 400 N.B. * Fan Speeds to 5 are for VMDM unit 00 VMDH * Fan speeds 00 0 * 00 * * VMDH VMDM *4 *5 VMDL 0. 0.5 0.6 0.7 0.8 m /s 0 00 * * VMDL * VMDM *4 *5 0. 0. 0. 5 m /s ( C Temperature Rise) 5 0 9kW 5 5.5kW.5kW 0 5 0. 0.5 0.6 0.7 0.8 m /s ( C Temperature Rise) 5 0 5 5 4.5kW 9kW.5kW Deep cooling coil. High density electric. heater. EU4 filter ( / dirty). Weather louvre. Clean filter. Plot this on fan chart and plot another point half the air volume and 5% of the static to draw in system resistance curve. You can now see that this system will give 0.5m /s airflow using the quiet VMDL unit or 0.68m /s with the VMDM at full speed (5). The ideal duty would be achieved using the VMDM with speed controller (Speed ). EXAMPLE An office area of 80m by.5m high requires ventilating at 0 air changes per hour. 80 X.5 X 0 = 0.56m /s X The input airflow requires filtering to a good standard (EU4) and electricity is the favoured winter heat source, controlled to minimise wasted energy. Using the top graph add the filter resistance (A) to the electric heater (B), silencer (C), weather louvre (D) and the external duct resistance (calculated from the duct layout) Pa A 5 B 5 C 5 D EXT. 00 8 Pa Total Static Pressure 5 0. 0 Deep cooling coil. High density electric heater. EU4 filter ( / dirty). Weather louvre. Clean filter. 0. 0. m /s Continue the fan airflow line to read off the ideal heater size.in this case a.5kw phase heater will give a C rise, which is sufficient to temper input air from - C to 9 C. 44 T: 0844 856 0590

Air Handling VMD Supply Air Handling Unit -Selection Graphs VMD Supply Air Handling Unit - Selection Graphs Component resistance 80 70 Pa 40 0 0 Pa 80 70 40 0 Component resistances 0. 0.5 0.6 0.56 0.7 0.8 m /s 0 0.7 0.8 0.9.0....4 m/s 4 400 00 0 00 * * N.B. * FAN SPEEDS to 5 ARE FOR VMDM UNIT * VMDM *4 *5 VMDL VMDH 800 700 0 0 400 00 0 * * * VMDH *4 VMDL * Fan speeds *5 0. 0.5 0.6 0.7 0.8m /s 00 0.7 0.8 0.9.0....4 m /s C (Temperature Rise) 5 0 5 5 0 9kW.5kW.5kW C (Temperature Rise) 0 5 7kW 6kW 5 0 0.7 0.8 0.9.0....4 m /s 5 0. 0.5 0.6 0.7 0.8 m /s Deep cooling coil. High density electric heater. EU4 filter ( / dirty). Weather louvre.. Clean filter. Deep cooling coil. High density electric heater. EU4 filter ( / dirty). Weather louvre. Clean filter. W: www.vent-axia.com/ahu 45