USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Similar documents
USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Ex LED light fittings

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Basic Ex products / Zone 1, 21

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

INSTRUCTION MANUAL (ATEX / IECEx)

High bay LED lighting fixture

Operating Instructions

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

WHO WE ARE AND WHAT WE DO

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

ARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

TECHNICAL SHEET. About the product

INSTRUCTION & SERVICE MANUAL

DTS Light fittings for explosive atmospheres

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

IP65 FLUO 2X17W 2X32W

CoreLine Waterproof the clear choice for LED

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Manual Power relay SR853

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

manual addendum DELPHI Ex

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Explosion Proof Combination Signal db (A) / 5 Joule

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

BSK-RPR Fire Damper. Additional operating instructions according to

Switches compliant with ATEX directive

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

XLFE-4/1. Borosilicate glass globe

SOLUZIONI PER ATMOSFERA ESPLOSIVA

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

VERSAFLOW VORTEX Supplementary instructions

OPTIBAR DP 7060 Supplementary Instructions

INSTRUCTION MANUAL (ATEX / IECEx)

BKA-EN Fire Damper. Additional operating instructions according to

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

CoreLine Wall-mounted the clear choice for LED

Flameproof Manual Call Points

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

OPTIWAVE X500 Supplementary Instructions

Illumination unit For sight glass level indicator Model LGI

Operating Manual Distribution box

CoreLine Batten the clear choice for LED

EWL. Supporting bracket

standards: standards:

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

new new Industrial plugs and sockets

Flameproof Manual Call Points Series MCP

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

PSFL , PSFL , PSFL , PSFL , PSFL

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Sylproof Superia LED G2

INTRINSICALLY SAFE LIGHTING RANGE

Waterproof TCW060 just light

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

OPTIBAR P 1010/2010 C Supplementary instructions

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Inductive slot sensor

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

INSTRUCTION MANUAL (ATEX / IECEx)

TECHNICAL SHEET. Indoor luminaire FIRA Matis. About the product FIRA DP, FIRA SP, FIRA DR

Integrated Solutions Low Voltage Systems

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Hazardous Area Portable Fan Heater The Bulldog

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Flow LED robust and streamlined

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

AZN ATEX INSTALLATION AND MAINTENANCE

Transcription:

CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9. Spare part and accessories 6 10. Inspection, maintenance, repair and overhaul 6 11. Responsibility and authorization 7 12. Storage and transport 7 13. Manufacturer s transport 7 14. Marking 7 1. MANUFACTURER TEP Ex d.o.o. Prilaz dr. Franje Tuđmana 6 HR-49210 ZABOK Tel: +385 49 222 900 Web: 2. GENERAL SAFETY INFORMATIONS W A R N I N G! The user manual contains basic information about the product. Mounting, installation, usage and maintenance should be carried out under this user manual to provide and ensure safe operation within the nominal characteristics. This user manual complement national Regulation and Standards. The responsible person shall ensure their implementation. Failure off implement this user manual can reduce explosion protection and endanger people, property and the environment. Any improper and illegal actions as well as non-compliance with the provisions of this user manual excludes all responsibility by manufacturer side. Before installation/commissioning: - Carefully read all instructions, - Execute proper training of responsible personnel, - Check that the contents of these instructions is fully understandable by the responsible personnel, - Make sure that all the requirements and national Regulations as well as all special security measures are applied. In lack of understanding: - Contact the manufacturer. During operation: - Ensure that this user manual and other work instructions are available to the responsible staff at all times, - Check the implementation of these instructions and all other safety user s instructions 1/7

3. PURPOSE Explosion proof fluorescent lighting fitting type 236 with autonomous power supply is intended for emergency (safety and replacement)) and general lighting space in industrial areas endangered explosive atmosphere, in Zones 1,2 and in areas endangered by explosive and flammable mixtures of dust and air in Zones 21, 22 accordance with EN 60079-10-1/-2: 2009. Ex fluorescent light fitting is used as fluorescent lighting fitting with two T8 (Ø26mm), 36W 2G13, fluorescent lamp in parallel configuration. 4. PRODUCT COMPLIANCE The product is in compliance with Regulations concerning equipment and protective systems for use in potentially explosive atmosphere, NN br. 34/10. The product complies with the ATEX Directive 94/9 EC and standards: - EN 60079-0:2012, - EN 60079-1:2007, - EN 60079-7:2007, - EN 60079-18:2009, - EN 60079-31:2009. The product has been developed, manufactured and tested according to the existing state of technique accordance with the standards EN 9001:2008 and EN ISO / IEC 80079-34:2011. The product is in compliance with the LV Directive 2006/95 EC. The product is in compliance with the RoHS Directive 2002/95 EC. The product is in compliance with EMC Directive 2004/108 EC. 5. DEGREE OF PROTECTION AND DATA Certificate: EXA 13 ATEX 0014 Marking: 2465 Category and explosion protection: Ambient temperature: -20ºC T a +55ºC II 2G Ex d e mb IIC T4 Gb II 2D Ex tb IIIC T80 C Db Mechanical protection: IP 66 Resistance to shock: IK 08 Class of protection: I (PE - protective earthing) Rated voltage: 220-240 V (±10%) Frequency: 50/60 Hz Rated current: 0,33 A Power factor: λ=0,95 Lifetime of lighting source: medium, 10,000 hours (long tube lifetime up to 70,000 hours, only on special request) Light source: fluorescent tube, 36W, T8-Ø26 mm, according to EN 60081:2008+A4:2012, lampholder G13 accordance with EN 62444:2013 Battery: Ni-Cd jd2, 6V/4Ah, IEC 61951-2:2011, microprocessor controlled battery charging and discharging. Rated battery autonomy: 1,5 hours Cable entry: Two cable glands Ex e M25x1,5, for cable diameters Ø6-15 mm and two Ex e plug in accordance with EN 62444:2013 Central interlocking switch (no-load condition) When the central interlocking switch is in position "OPEN" internal elements of the lamps are in no-load condition (electronic control gear, head of G13...). The interlocking switches power on a flashlight after closing the cover and rotate the lock switch in position "CLOSE". In case of failure or lack of one of the fluorescent tubes, electronic control gear type SMP 07/12 shuts off the power to the malfunctioned fluorescent tubes. Housing: SMC, polyester plastic reinforced with glass fiber, color RAL 7038 Diffuser: PC, polycarbonate plastic Dimension: 1370 x 200 x 130 (L x W x H) Weight: 10 kg 2/7

6. TYPE MODEL CODE WATAGE LAMP TYPE NOMINAL VOLTAGE LUMINOUS FLUY [lm] LAMP HOLDER NOMINAL OPERATIONAL CURRENT WEIGHT 236 2x36 W T8 220-240 V 2 x 3350 G13 0,33 A 10 kg 7. MOUNTING AND INSTALATION Fluorescent lighting fitting comes standard with fluorescent tubes, special wrench for open the lid, two Ex-e cable glands M25 (for cable 6-15mm), two Ex-e plug M25 and accessories for suspension assembly ( 30-150). The lamp is designed for indoor and outdoor use. Notes for safe installation and assembly: Check the ambient temperature Possibility of installation in hazardous areas 1, 2, 21, 22 Checking of cable entry into the fluorescent lighting fitting (compromised mechanical protection, IP number) Damage lamps distort explosion protection of the area in which it is installed! Opening and closing of the fluorescent light fitting: Remove the rubber protection on the central lock switch. Turn the central axis 180 to the left (marking - OPEN) with a socket wrench. Sliders release transparent cover and the lamp opens. When closing follow the orders of operations in reverse. When closing, pay special attention to the positioning of the seal (slot in the cover) relative to the housing. By turning the central lock switch, the fluorescent light fitting is in no-load state The main connections terminals: L, N In the open position, the mechanical lock prevents access to the interlocking switches USE MODERATE FORCE WHEN OPENING! Replacing of the fluorescent tubes ("two contacts" lamp holder G13) Set both ends of the fluorescent tube in the lamp holder grooves, then perform the rotation of the fluorescent tubes in the left or right side. Internal reflector, with G13 lamp holders and T8 fluorescent tubes, is with reflector hinges and reflector lends carriers attached to the base plate at six different sites (three on each side). 3/7

Gaining access to the terminals is achieved by rotating assembly of the reflector. Note: it is possible to separate the two hinge reflector lends from the bracket and gain access to the other side of the terminals by rotating assembly of the reflector lends to the other side. Closing is done in reverse order of actions by bringing hinge reflector lends back to mount of the reflector lends only by light hand pressure. 4/7

Wiring diagram 236 Wiring connection should be done according to wiring diagram above. WARNING! Before connecting lamp to source voltage, two terminals (X1 on wiring diagram) needs to be shortcut connected. This way the battery is put in function again. (current circuit from the battery to the emergency modul was disrupted at terminals X1 to avoid discharging battery during transportation). Also testing between phase L2 and neutral N conductors should not be done, otherwise, the electronic module in the lamp can be destroyed! DIMENSION 200 L1 1370 130 M25 M8 800 L2 5/7

9. SPARE PART AND ACCESSORIES SKICA OPIS OZNAKA ZA NARUDŽBU SKICA OPIS OZNAKA ZA NARUDŽBU Diffuser 236 20-120 Ex e cable gland SPU 25 SPU 25 Gasket 236 20-130 Ex e plug M25 SPC 25 Internal reflector with lamp holder G13 236 20-140 Ceiling mounting set 30-110 El. Ballast SMP 07/12 SMP 07/12 Pipe mounting set 30-120 Terminals 5x2,5mm 2 236 20-150 Wall mounting set 30-130 Socket key SW8 236 20-160 Ring bolt M8 30-140 Pendant mounting set 30-150 Metal cable glands for reinforced cable M25 (cable Ø13-21mm), set 30-160 10. INSPECTION, MAINTENANCE, REPAIR AND OVERHAUL Inspections are carried out in accordance with IEC 60079-17:2007 / C 1: 2008, general and special conditions of manufacturer and users Regulations and includes supervision of parts on which the explosion protection depends, especially: - the housing, diffuser, cable gland, plugs and seal are without rupture and damage, - the glands, plugs, terminals, pressure screw, intermediate gland, screw of the glass cover are fastened with nominal torque All the repairs are performed by the manufacturer or the manufacturer's authorized personal and the original parts must be provided according to the product documentation, all in accordance with EN 60079-19:2011. Overhaul and modifications are not allowed. If repair or any other procedure are performed on the product by unauthorized person, all producer responsibility for the product and the warranty and the manufacturer's declaration of conformity becomes invalid. 11. RESPONSIBILITY AND AUTHORIZATION This instruction is the basic information about the product. It is completed by the corresponding national laws and regulations. Production, use, certification and supervision are determined at the national level: a) Regulations concerning equipment and protective systems intended for use in potentially explosive atmospheres EU directive 94/9 EC (ATEX 94) b) Regulations on minimum requirements for safety and health protection of workers and technical inspection of facilities, equipment, installations and equipment in hazardous areas EU directive 1999/92/EC (ATEX 137). The responsible person shall ensure their implementation at the working facility 12. STORAGE AND TRANSPORT Transportation and warehousing of the lamps is only allowed in the original packaging, as outlined in a cardboard box. 6/7

13. MANUFACTURER'S WARRANTY The manufacturer provides a warranty on the product for a period of one year under the provisions of this user manual and the law on obligations. This statement has the force of Warranty sheet. 14. MARKING Explosion protected fluorescent lighting fitting type SIF.36-. is marked with: - marking label on housing of lamp with technical and certification data: HR - 10090 Zagreb 236 230-240 V 50-60 Hz 2x36 W T8 G13 IP66 II 2G Ex d e mb IIC T4 Gb II 2D Ex tb IIIC T80 C Db EXA 13 ATEX 0014-20 C<Ta<+50 C MA... DAT... 2465 OPEN CLOSE - label with technical and certification data on internal reflector inside housing: HR - 10090 Zagreb 236 230-240V 50-60Hz 2x36W T8 G13 IP66 II 2G Ex d e mb IIC T4 Gb II 2D Ex tb IIIC T80 C Db 2465 EXA 13 ATEX 0014-20 C<Ta<+50 C MA... DAT... - text on diffuser ( of the tool): 7/7