47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type)

Similar documents
Digital Panel Meters 47 Series. DC INPUT DIGITAL PANEL METER (4 1/2 digit, LED display type) Model: 47LV OPERATING MANUAL

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

MODEL: 47NLVT. Digital Panel Meters 47NL Series. POWER INPUT DC Power R: 24 V DC

MODEL: 47NLDYT. [2] OPTIONS blank: none /Q: With options (specify the specification) Digital Panel Meters 47NL Series

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Series Temperature Controller Instruction Sheet

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

GCS-300 No.GCS31E

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

DIGITAL INDICATOR JIR-301-M

LC3000 Level Controller Installation and Maintenance Instructions

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Process Alarm Module RTA 421

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Class 1 laser beam sensor safe for your eyes

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

Temperature Controllers

AE500 Instruction Manual

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

I/O ZONE 560/583 AND OPERATION MANUAL

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

ISOLATOR SGI SGIW INSTRUCTION MANUAL

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

OPTISENS TUR 2000 Technical Datasheet

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Instruction Manual August sitrans CU 02

MICRO CONTROLLER S Z SERIES

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Multi-Gas-Controller MGC2

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

Room Temperature Controllers

Technical Data. General specifications. Rated operating distance s n 5 mm

Digital Room Thermostat for Heating Applications with 7-Day Time Program

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Speed and Frequency Seite 1 von 7

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Flush-mounted room thermostat

Room Temperature Controller

Inductive slot sensor

SITESTAR CABINET DESCRIPTION

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

INSTALLATION INSTRUCTIONS

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Flush-mounted room thermostats

UDC100 Universal Digital Controller Specifications

INSTALLATION INSTRUCTIONS

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

vibration switch

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Process & TeMPerATUre UniversAl input DigiTAl MeTers

MR3CCUHV Temperature/Defrost Control

TEMPERATURE CONTROL MODULE MODEL R3-TC2

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Thermal Management Products & Accessories for Enclosures

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Power Supply Display Module PSDM. Installation and Operation Manual

Fisher LCP100 Local Control Panel

RE-PR3-E-27 3-Phase Panel Mount 27kW

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

IS Series Pressure Sensing Switches

Room thermostats with LCD RDD100..

Transcription:

INSTRUCTION MANUAL DC DIGITAL PANEL METER ( / digit, LED display type) MODEL LV BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE INCLUDES: Digital panel meter (body mounting bracket watertight packing)...() Engineering unit sticker label sheet...() MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. For detailed explanations to operate and program the module, please refer to Model LV Operating Manual (EM-50-B), downloadable at M-System s web site: http:// www.m-system.co.jp..00 marked parameters are usable with the product version.00 or higher. POINTS OF CAUTION CONFORMITY WITH EU DIRECTIVES This equipment is suitable for Pollution Degree, Measurement category II (alarm output, transient voltage 500V) and Installation Category II (transient voltage 500V). Reinforced insulation (input or DC output to alarm output to power: 00V) and basic insulation (input to DC output: 00V) are maintained. Prior to installation, check that the insulation class of this unit satisfies the system requirements. Altitude up to 000 meters. The equipment must be installed such that appropriate clearance and creepage distances are maintained to conform to CE requirements. Failure to observe these requirements may invalidate the CE conformance. The actual installation environments such as panel configurations, connected devices, connected wires, may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conformity. In order to enable the operator to turn off the power input immediately, install a switch or a circuit breaker according to the relevant requirements in IEC 60- and properly indicate it. RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below: 00 0V AC rating: 5 6V, 50/60 Hz, approx. 6.5VA V DC rating: V ±0%, approx. W 0V DC rating: 5 50V, approx. W GENERAL PRECAUTIONS Before you remove the unit or mount it, turn off the power supply and input signal for safety. Be sure to put the terminal cover on while the power is supplied. ENVIRONMENT Indoor use. When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within -0 to 55 C ( to F) with relative humidity within 0 to 0% RH in order to ensure adequate life span and operation. Be sure that the ventilation slits are not covered with cables, etc. REQUIREMENTS TO ENSURE IP66 Observe the designated panel cutout size (W H5 mm). The watertight packing included in the product package must be placed behind the front cover. Both mounting brackets must be fastened tightly until they hit the panel. Confirm visually that the packing is not contorted or excessively run off the edge after installation. WIRING Make sure for safety that only qualified personnel perform the wiring. Do not install cables close to noise sources (high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. EX-FACTORY SETTING (/SET) Activating initialization of Lockout Setting Mode, Exfactory settings or user s specified parameters will be deleted and overwritten with the factory default values. Notice that after this, Ex-factory settings will be irrecoverable. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 0 minutes is required for satisfying complete performance described in the data sheet. 5--55, Minamitsumori, Nishinari-ku, Osaka 55-006 JAPAN Phone: (6)665-0 Fax: (6)665-50 E-mail: info@m-system.co.jp EM-50-A Rev.6 P. / 5

COMPONENT IDENTIFICATION n TOP VIEW Strap Specifications Watertight Packing n FRONT VIEW () Main Display n SIDE VIEW Mounting Bracket Terminal Cover () Alarm Indicators () Function Indicators HH H P L LL Zro Spn D/P Tch Fnc Min Max Max/Min Alarm/ Scale/ Shift Up () Max/Min Button (5) Alarm/ Button () Shift Button (6) Scale/ Button () Up Button COMPONENT IDENTIFICATION No. COMPONENT FUNCTION () Main display Indicates present values, setting values and status of the unit. () Alarm indicators * Indicate alarm status of the input signal. LL turns on when the LL alarm is tripped. L turns on when the L alarm is tripped. H turns on when the H alarm is tripped. HH turns on when the HH alarm is tripped. P turns on when none of the other alarms is tripped. () Function indicators Indicate the status in each setting mode. () Max/Min button Used to switch the main display to show the present values, maximum values or minimum values etc. (5) Alarm/ button Used to confirm alarm setting value and to move on to the alarm and other setting modes; or to shift through setting items in each setting mode. (6) Scale/ button Used to move on to the scaling and other setting modes; or to shift through setting items in each setting mode. () Shift button Used to move on to the setting standby status of each setting mode and shift through display digits in each setting item. () Up button Used to change setting values, to execute/cancel Forced Zero or to select setting values. *. Only the P indicator turns on with no-alarm-output type. LL or HH does not turn on with dual-alarm-output type. All setpoints can be independently set either for Hi or Lo alarm trip. 5--55, Minamitsumori, Nishinari-ku, Osaka 55-006 JAPAN Phone: (6)665-0 Fax: (6)665-50 E-mail: info@m-system.co.jp EM-50-A Rev.6 P. / 5

INSTALLATION 5 0 0.6 0 0. min. 5 HOW TO MOUNT THE UNIT ON A PANEL The watertight packing must be in place to hold the meter. Do not remove it. ) Insert the unit into the panel cutout. ) Push the mounting brackets into the grooves on both sides of the rear module, until they hit the panel s rear side. Watertight packing Panel Mounting Bracket min. 0 Panel thickness:.6 to.0 mm TERMINAL CONNECTIONS Connect the unit as in the diagram in the following page or refer to the connection diagram on the terminal cover. EXTERNAL DIMENSIONS unit: mm (inch) TOP VIEW 5 (.) FRONT VIEW 0 (.06) SIDE VIEW.5 (.) 6 (.).5 (.) 6 (.) (.0) (.) (.5) REAR VIEW No Alarm Output Alarm Output 6.6 (.6) 0M SCREW TERMINAL 0M SCREW TERMINAL M SCREW M SCREW 5 (.) 5 6 0 5 6 0 5 6 0.5 (.60) 5--55, Minamitsumori, Nishinari-ku, Osaka 55-006 JAPAN Phone: (6)665-0 Fax: (6)665-50 E-mail: info@m-system.co.jp EM-50-A Rev.6 P. / 5

CONNECTION DIAGRAM ALARM OUTPUT CODE 0: No alarm output 0 U() Input code:, Input code: Input code: Input code : 5, 6 V V I V I COM COM ALARM OUTPUT CODE : N.O. contact, points ALARM OUTPUT CODE : SPDT contact, points 5 6 0 0 HHa HH OUTPUT Ha H OUTPUT Hc, HHc La L OUTPUT LLa LL OUTPUT Lc, LLc U() 5 6 0 0 Ha (NO) Hb (NC) Hc (COM) La (NO) Lb (NC) Lc (COM) U() H OUTPUT L OUTPUT Relay Protection AC Powered LOAD U DC Powered LOAD Inductive Load (Coil) Varistor or CR Circuit Inductive Load (Coil) Diode, Varistor or CR Circuit Note: The section enclosed by broken line is only with DC output option. Input Terminal Assignments TYPE MEASURING (indicator) RANGE TERMINALS V00 V0 ±00V ±0V V5 ±5V V ±V A- ±A A- ±A V00 ±00V V0 V00 ±00mV ±0mV TYPE MEASURING (indicator) RANGE TERMINALS V0-5 V-5 0 5V 5V A00 A ±00mA ±ma A0-0 0mA A- A0 0mA ±00μA TERMINAL BLOCK How to remove the terminal cover Insert the minus tip of a screwdriver into each hole at the four corners of the cover and pull it to the direction as indicated below to separate the terminal cover. Terminal Cover How to remove the terminal block The terminal block is separable in two pieces. Loosen two screws on both sides of the terminal block to separate. Be sure to turn off the power supply, input signal and power supply to the output relays before separating the terminal block. Terminal Block Separable Terminal Block Screw 5--55, Minamitsumori, Nishinari-ku, Osaka 55-006 JAPAN Phone: (6)665-0 Fax: (6)665-50 E-mail: info@m-system.co.jp EM-50-A Rev.6 P. / 5

WIRING INSTRUCTIONS SCREW TERMINAL Torque: 0.6 N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. Applicable wire size: 0.5 to.65 mm (AWG to 6) Recommended manufacturer: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd. (.) max 6 (.) max mm (inch) LIGHTNING SURGE PROTECTION M-System offers a series of lightning surge protectors for protection against induced lightning surges. Please contact M-System to choose appropriate models. 5--55, Minamitsumori, Nishinari-ku, Osaka 55-006 JAPAN Phone: (6)665-0 Fax: (6)665-50 E-mail: info@m-system.co.jp EM-50-A Rev.6 P. 5 / 5