1 INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller GCS-00 No.GCS1E To prevent accidents arising from the use of this controller, please ensure the operator receives this manual. Caution This instrument should be used in accordance with the specifications described in the manual. If it is not used in accordance with the specifications, it may malfunction or cause fire. Be sure to follow the warnings, cautions and notices. If they are not followed, it could cause serious injury or malfunction. Specifications of the GCS-00 and the contents of this instruction manual are subject to change without notice. Care has been taken to assure that the contents of this instruction manual are correct, but if there are any doubts, mistakes or questions, please inform our sales department. Be sure to turn the power supplied to the instrunment when cleaning. Use a soft, dry cloth when cleaning the instrument. (Alcohol based substances may cause tarnishing or defacement of the unit) As the display section is vulnerable, do not strike or scratch it with hard objects. Any unauthorized transfer or copying of this document, in part or in whole, is prohibited. Shinko Technos Co., Ltd. is not responsible for any damages or secondary damages incurred as a result of using this product, including any indirect damages. 1. Model name 1.1 Model name G C S /, Series name: GCS-00 (W8 x H8 x D9.5mm) Control action PID 0 No alarm action Alarm 1 (A1) A Alarm action applied (Selectable by key operation) R Relay contact: 1a Control output S Non-contact voltage (for SSR drive): V DC A Current: to 20mA DC E Thermocouple: K, J, E Input R RTD: Pt100, JPt100 M Multi-range A2 Alarm 2 (A2) W( 5A) CT rated current: 5A W(10A) Heater burnout CT rated current: 10A W(20A) alarm CT rated current: 20A W(50A) CT rated current: 50A C5 Serial communication RS-85 SM Setting value memory (External selection) Option Multi-range function MR This option is applicable for the thermocouple and RTD input types. For the multi-range input type, this option is standard. LA Loop break alarm BK Color: Black BL Screw type mounting bracket IP Dust-proof Drip-proof (IP5) TC Terminal cover 1
2 1.2 How to read the model nameplate Model nameplates are attached to the right side of the case and the bottom of the internal assembly. (1) (2) () G C S A R / E W ( 2 0 A ) B K N o. Relay contact output/thermocouple input Heater burnout alarm output [The specified current value is entered in ( ).] Color black (1): Model name (2): Option codes (): Serial number (Indicated only on the internal assembly) 2. Name and functions of the sections (1) PV: PV display Indicates the Process variable (PV) with a red LED. (2) SV: SV display Indicates the Setting value (SV) with a green LED. () AT: Auto-tuning indicator The dot at the end of the PV display flashes while the Auto-tuning or Auto-reset is performing. () OUT: Control output indicator A green LED lights when the control output is on. (5) A1: Alarm 1 (A1) indicator A red LED lights when Alarm 1 (A1) output is on. () A2: Alarm 2 (A2) indicator (Option: A2) A red LED lights when Alarm 2 (A2) output is on. () HB: Heater burnout alarm indicator (including Sensor burnout alarm) [Option: W] A yellow LED lights when the Heater burnout alarm or Sensor burnout alarm output is on. () (1) () (8) Increase key : Increases the numeric value or selects the setting value. (2) (5) () () (9) Decrease key : Decreases the numeric value or selects the setting value. (10) Mode key : Selects the setting mode or registers the setting value by pressing this key. (11) OUT/ key: Turns the control output on or off. (Fig. 2-1). Operation The PV display indicates the sensor type character and temperature unit, and the SV display indicates the rated scale maximum value for approx. 2 seconds after the power is turned on. See [table.1-1]. (When any other value has been set during the Main setting value high limit setting, the SV display indicates the value.) During this time, all outputs and LED indicators are in status. After that, the PV display indicates an actual temperature, SV display indicates main setting value and control starts. (When the control output function is working, To release the control output function, press the [Table.1-1] Input K K J E Pt100 JPt100 (8) (9) (10) (11) PV SV PV SV is indicated on the PV display. key for 1 second.) 2
3 .1 Operation flowchart PV/SV display mode (Approx. 1s) Control output function Output MV (manipulated variable) indication (Approx. s) + + (Approx. s) + + (Approx. s) [Main setting mode] [Sub setting mode] [Auxiliary function setting mode 1] [Auxiliary function setting mode 2] Main setting 1 AT Perform/Cancel or Setting value lock designation Sensor selection Auto-reset Perform [ / ] Main setting 2 Proportional band setting Main setting value high limit setting PV filter time constant setting Integral time setting Main setting value low limit setting Output high limit setting Derivative time setting Sensor correction setting Output low limit setting Proportional cycle setting Instrument number setting Output / hysteresis setting Alarm 1 (A1) setting Communication speed setting Alarm 1 (A1) action selection Alarm 2 (A2) setting Alarm 2 (A2) action selection Heater burnout alarm setting Alarm 1 (A1) Energized/ Deenergized selection Loop break alarm time setting Alarm 2 (A2) Energized/ Deenergized selection Loop break alarm span setting Alarm 1 (A1) hysteresis setting Alarm 2 (A2) hysteresis setting Alarm 1 (A1) action delayed timer setting Alarm 2 (A2) action delayed timer setting Direct/Reverse control action : The items with dotted lines are optional and they appear only when the options are added. Auto-tuning bias setting + : Press the key while holding down the key. + (Approx. s): Press the key for seconds while holding down the key. + + (Approx. s): Press the key for seconds while holding down the and keys.
4 .2 Main setting mode Character Name, Description, Setting range Default Main setting 1 0 ( ) Sets the 1st main setting value for the main control. Setting range: Main setting value low limit to main setting value high limit Main setting 2 Sets the 2nd main setting value for the main control. Available only when option [SM] is applied. Setting range: Main setting value low limit to main setting value high limit 0 ( ). Sub setting mode Character Name, Description, Setting range Default Auto-tuning Perform/Cancel, or Auto-reset Perform Designates auto-tuning perform/cancel, or auto-reset perform. Auto-reset will be cancelled in approx. minutes automatically. Proportional band value setting Sets the proportional band for the control output. / action when setting the value to 0 or 0.0. Setting range: 0 to 999 ( ), or 0.0 to 99.9 Integral time setting Sets the integral time for the control output. Setting the value to 0 disables the function. With PD action ( I value is set to 0), auto-reset can be performed. Setting range: 0 to 999 seconds Derivative time setting Sets the derivative time for the control output. Setting the value to 0 disables the function. Setting range: 0 to 00 seconds Proportional cycle setting Sets the proportional cycle value for the control output. Not available for / action or current output type. Setting range: 1 to 120 seconds Alarm 1 (A1) setting Sets the action point for Alarm 1 (A1) output. Not available for the GCS-0 type. Not available if No alarm action is selected during Alarm 1 (A1) action selection. Setting range: See table [.-1]. Alarm 2 (A2) setting Sets the action point for Alarm 2 (A2) output. Not available if option [A2] is not applied, or No alarm action is selected during Alarm 2 (A2) action selection. Setting range: See Table [.-1]. Heater burnout alarm setting Sets the heater current value for Heater burnout alarm. Available only when the option [W] is applied. Self-holding is not available for the alarm output. For the rated current 5A, 0.0 to 5.0A For the rated current 10A, 0.0 to 10.0A For the rated current 20A, 0.0 to 20.0A For the rated current 50A, 0.0 to 50.0A Loop break alarm time setting Sets the time to assess the Loop break alarm. Available only when the option [LA] is applied. Setting range: 0 to 200 minutes Loop break alarm span setting Sets the temperature span to assess the Loop break alarm. Available only when the option [LA] is applied. Setting range: 0 to 150 ( ) 10 (20 ) 200s 50s R/ : 0s S/ : s 0 ( ) 0 ( ) 0.0A 0 min. 0 ( )
5 [Table.-1] Alarm action Setting range Setting range (with a decimal point) High limit alarm -199 to Input range maximum value ( ) to 99.9 Low limit alarm -199 to Input range maximum value ( ) to 99.9 High/Low limits alarm (0 to Input range maximum value) ( ) (0.0 to 99.9) High/Low limit range (0 to Input range maximum value) ( ) (0.0 to 99.9) Process high alarm Input range minimum to Input range maximum Input range minimum to Input range maximum Process low alarm Input range minimum to Input range maximum Input range minimum to Input range maximum High limit w/standby -199 to Input range maximum value ( ) to 99.9 Low limit w/standby -199 to Input range maximum value ( ) to 99.9 Hi/Lo limits w/standby (0 to Input range maximum value) ( ) (0.0 to 99.9). Auxiliary function setting mode 1 Character Name, Description, Setting range Default Setting value lock designation Locks the setting value to prevent errors. The setting item to be locked is dependant on the designation. PID auto-tuning or auto-reset will not function if Lock 1 or Lock 2 is designated. Unlock (Unlock): All setting values can be changed. (Lock 1): None of the setting values can be changed. (Lock 2): Only main setting value can be changed. (Lock ): All setting values can be changed, however, they return to their former value after the power is turned off because they are not saved in the non-volatile memory. Since this function has no relation to the memory life, it is well suited for the PC-900 with the option [SVTC]. Main setting value high limit setting Sets the high limit value for the main setting. Setting range: Main setting value low limit to Rated maximum value Rated maximum value Main setting value low limit setting Sets the low limit value for the main setting. Setting range: Rated minimum value to Main setting value high limit Sensor correction setting Sets sensor correction value of the sensor. Setting range: -199 to 200 ( ), or to 20.0 Instrument number setting Sets the instrument number individually to each instrument when communicating by connecting multiple instruments in serial communication. Available only when the option [C5] is applied. Setting range: 0 to 95 Communication speed selection Selects the communication speed to be equal to that of the host computer. Available only when the option [C5] is applied. 200bps: 800bps: 900bps: 19200bps: Rated minimum value 0 ( ) or bps 5
6 .5 Auxiliary function setting mode 2 Character Name, Description, Setting range Default Sensor selection K (0 to In the case of multi-range input type, one input type can be selected from 999 ) Thermocouple ( types) and RTD (2 types), and the unit or can be selected as well. Available only when the option [MR] is applied to the thermocouple or RTD input types. The option [MR] cannot be applied to the type thermocouple K (0 to 00 ). K 0 to 999 : J 0 to 999 : E 0 to 00 : Pt to 00 : JPt to 00 : Pt to 99.9 : JPt to 99.9 : K 0 to 999 : J 0 to 999 : E 0 to 999 : Pt to 999 : JPt to 999 : PV filter time constant setting 0.0s Sets PV filter time constant value. If the value is set too large, it affects control result due to the delay of response. Setting range: 0.0 to 10.0 seconds Output high limit setting 100% Sets the output high limit value. Not available for / action. Setting range: Output low limit value to 105% (Setting greater than 100% is effective for the current output type.) Output low limit setting 0% Sets the output low limit value. Not available for / action. Setting range: -5% to Output high limit value (Setting less than 0% is effective for the current output type.) Output / hysteresis setting 1.0 Sets the / action hysteresis for the control output. Available only for / action. Setting range: 0.1 to 99.9 Alarm 1 (A1) action selection Selects Alarm 1 (A1) action. Not available for the GCS-0 type. No alarm action : High limit alarm : Low limit alarm : High/Low limits alarm : High/Low limit range alarm : Process high alarm : Process low alarm : High limit alarm w/standby : Low limit alarm w/standby : High/Low limits alarm w/standby : Alarm 2 (A2) action selection Selects Alarm 2 (A2) action. Available only when the option [A2] is applied. Alarm action types are the same as those of Alarm 1 (A1). No alarm action No alarm action
7 Alarm 1 (A1) Energized/Deenergized selection Selects Alarm 1 (A1) output Energized or Deenergized. Not available for the GCS-0 type. Not available if No alarm action is selected during Alarm 1 (A1) action selection. Energized : Deenergized: Alarm 2 (A2) Energized/Deenergized selection Selects Alarm 2 (A2) Energized or Deenergized. Not available if the option [A2] is not applied, or if No alarm action is selected during Alarm 2 (A2) action selection. Selection items are the same as those of Alarm 1 (A1) Energized/ Deenergized selection. Alarm 1 (A1) hysteresis setting Sets hysteresis value for Alarm 1 (A1) output. Not available for the GCS-0 type. Not available if No alarm action is selected during Alarm 1 (A1) action selection. Setting range: 0.1 to 99.9 ( ) Alarm 2 (A2) hysteresis setting Sets hysteresis value for Alarm 2 (A2) output. Not available if option [A2] is not applied, or if No alarm action is selected during Alarm 2 (A2) action selection. Setting range: 0.1 to 99.9 ( ) Alarm 1 (A1) action delayed timer setting Sets the action delayed timer for Alarm 1 (A1). The alarm is activated when the setting time has passed after the input enters alarm output range. Not available for the GCS-0 type. Not available if No alarm action is selected during Alarm 1 (A1) action selection. Setting range: 0 to 999 seconds Alarm 2 (A2) action delayed timer setting Sets the action delayed timer for Alarm 2 (A2). The alarm is activated when the setting time has passed after the input enters alarm output range. Not available if option [A2] is not applied, or if No alarm action is selected during Alarm 2 (A2) action selection. Setting range: 0 to 999 seconds Direct/Reverse control action Selects the control action Reverse (Heating) or Direct (Cooling). Reverse (Heating) action : Direct (Cooling) action : Auto-tuning bias setting Sets auto-tuning bias value during PID auto-tuning. Setting range: 0 to 50 (0 to 100 ), or 0.0 to 5.0 Energized Energized 1.0 ( ) 1.0 ( ) 0s 0s Reverse (Heating) action 20 (0 ) Sensor correction function This corrects the input value from the sensor. When a sensor cannot be set at a location where control is desired, the sensor measuring temperature may deviate from the temperature in the controlled location. When controlling with multiple controllers, sometimes the measured temperatures (input value) do not concur with the same setting value due to difference in sensor accuracy or dispersion of load capacities. In such a case, the control can be set at the desired temperature by shifting the input value of sensors.
8 Loop break alarm The alarm will be activated when the process variable (PV) does not rise as much value as the span or greater within the time it takes to assess the loop break alarm after the manipulated variable has reached 100% or the output high limit value. The alarm will also be activated when the process variable (PV) does not fall as much value as the span or greater within the time it takes to assess the loop break alarm after the manipulated variable has reached 0% or the output low limit value. When the control action is Direct (Cooling), read fall for rise and vice versa. Energized/Deenergized function [If alarm action Energized is selected] The alarm output (terminals -, or -5) is conducted () while the alarm output indicator is lit The alarm output is not conducted () while the alarm output indicator is not lit. [If alarm action Deenergized is selected] The alarm output (terminals -, or -5) is not conducted () while the alarm output indicator is lit. The alarm output is conducted () while the alarm output indicator is not lit. Main setting Alarm setting (High limit alarm Energized) (High limit alarm Deenergized) (Fig..5-1) (Fig..5-2) Setting value memory (External selection) If the option [SM] is applied, the setting value memory number can be selected by external operation. (However, only No. 2 can be selected.) To select Setting value memory number 2, connect terminal 1 to 1. Memory number cannot be changed during setting mode or PID auto-tuning.. Control output function Character Name, Description Control output function This is the function to turn the control output even if the power to the instrument is supplied. The function is used when required to halt the control action or when the GCS-00 is not used in multiple controllers. is indicated on the PV display while the function is working. This function can be selected from any mode or from any setting item by pressing the key for approx. 1 second. Once this function is enabled, the function cannot be released even if the power to the instrument is turned off and on again. To cancel the function, press the key again for approx. 1 second.. Output MV (manipulated variable) indication Name, Description Output MV (manipulated variable) indication Press the key for seconds on the PV/SV display mode. The main setting mode appears in the process, however, if the key is pressed continuously, output manipulated variable is indicated on the SV display and the decimal point flashes every 0.5 seconds. By pressing the key again, the mode reverts to the PV/SV display mode. 8 Main setting Alarm setting
9 . Running After the controller has been mounted to the control panel and wiring is completed, it can be started in the following manner. (1) Turn the power supply to the GCS-00. For approx. 2 seconds after the power on, the sensor type characters and temperature unit are indicated on the PV display, and the rated maximum value is indicated on the SV display. See [table.1-1]. (If any other value is set during the Main setting value high limit setting, SV display indicates the value.) During this time, all outputs and LED indicators are in off status. After that, the PV display indicates the current temperature, and the SV display indicates the main setting value. While the Control output function is working, is indicated on the PV display. (2) Input the setting value. Input each setting value referring to Chapter Operation. () Turn the load circuit power. Starts the control action so as to maintain the controlled object at the main setting value. 5. Other functions (1) Input abnormality indication When the input value exceeds 999 (99.9), digits on the PV display flash. When the input value exceeds [the rated scale maximum value + 50 (100 )], the control output is turned (for the current output type, output low limit value), and the PV display flashes. When the input falls below -199 (-19.9), digits on the PV display flash. When the thermocouple input value falls below -50 (-100 ), the control output is turned (for the current output type, output low limit value), and the PV display flashes. For the RTD input whose rated scale minimum value is -19.9, if the input value falls below -50 (-100 ), the control output is turned (for the current output type, output low limit value), and the PV display flashes. For the RTD input whose rated scale minimum value is -199, if the input value falls below [-199 1% of the rated scale span], the control output is turned (for the current output type, output low limit value), and the PV display flashes. (2) Sensor burnout (Burnout) When the thermocouple or RTD is burnt out, the control output is turned (for the current output type, output low limit value), and the PV display flashes. () Self-diagnosis The CPU is monitored by a watchdog timer, and when any abnormal status is found on the CPU, the controller is switched to warm-up status. () Automatic cold junction temperature compensation (thermocouple input type) This detects the temperature at the connection terminal between thermocouple and the instrument, and always keeps it on the same status as when the reference junction is located at 0 (2 ). 9
10 . Action explanation.1 Standard control action Heating (Reverse) action Cooling (Direct) action Control action Proportional band Proportional band SV setting SV setting Relay contact output Non-contact voltage output DC current output Cycle action is performed according to deviation Cycle action is performed according to deviation V DC 12/0V DC 0V DC 0V DC 0/12V DC 12V DC Cycle action is performed according to deviation Cycle action is performed according to deviation mA DC 20 to ma DC ma DC ma DC to 20mA DC 20mA DC Indicator (OUT) Green Changes continuously according to deviation Lit Changes continuously according to deviation Lit part : Acts or..2 / action Heating (Reverse) action Cooling (Direct)action Control action SV setting SV setting Relay contact output Non-contact voltage output + 12V DC + 0V DC + 0V DC + 12V DC DC current output mA DC ma DC + ma DC + 20mA DC Indicator (OUT) Green Lit Lit part: Acts or. 10
11 . Alarm action High limit alarm action Low limit alarm action High/Low limits alarm action Alarm action Output Indicator Main setting value Lit High/Low limit range alarm action Alarm setting Alarm setting Main Main setting value Alarm setting setting value Alarm setting Lit Process high alarm action Lit Lit Process low alarm action Alarm action Output Indicator Alarm action Output Indicator Alarm setting Main Alarm setting Alarm setting setting value Alarm setting Lit High limit alarm with standby Low limit alarm with standby Lit High/Low limits alarm with standby Main setting value Alarm setting Alarm setting Main setting value Alarm setting Main setting value Lit Lit Lit Lit Lit Alarm setting part: Acts or. part: The standby functions. Use terminals 5 and for Alarm 2 (A2).. Heater burnout alarm action Heater burnout alarm action Alarm action Setting Small Load current Large Output 5 5 Indicator Lit 11
12 . PID auto-tuning In order to set each value of P, I, D and ARW automatically, the auto-tuning process should be made to fluctuate to obtain an optimal value. In the case of a large difference between the setting value and processing temperature as the temperature is rising When AT bias is set to 20, the AT process will fluctuate at the temperature 20 lower than the setting value. Setting value Temperature Temperature 20 lower than the setting value () (1) Calculating PID constant (2) PID constant calculated () Controlled by the PID constant set by auto-tuning. () AT bias value AT starting point Time (1) (2) () (Fig. -1) In the case of a stable control The AT process will fluctuate around the setting value. Setting value Temperature (1) Calculating PID constant (2) PID constant calculated () Controlled by the PID constant set by auto-tuning. AT starting point Time (1) (2) () (Fig. -2) In the case of a large difference between the setting value and processing temperature as the temperature is falling When AT bias is set to 20, the AT process will fluctuate at the temperature 20 higher than the setting value. Temperature Setting value () Temperature 20 higher than the setting value (1) Calculating PID constant (2) PID constant calculated () Controlled by the PID constant set by auto-tuning. () AT bias value AT starting point Time (Fig. -) (1) (2) () 12
13 8. Mounting to the control panel 8.1 Site selection This instrument is intended to be used under the following environmental conditions (IEC1010-1): Overvoltage category, Pollution degree 2 Ensure the mounting location corresponds to the following conditions: (1) A minimum of dust, and an absence of corrosive gases (2) No flammable, explosive gases () No mechanical vibrations or shocks () No exposure to direct sunlight, an ambient temperature of 0 to 50 (2 to 122 ) that does not change suddenly (5) An ambient non-condensing humidity of 5 to 85%RH () The controller away from large capacity electromagnetic switches or cables through which large current flows () No water, oil or chemicals or where the vapors of these substances can come into direct contact with the controller 8.2 External dimensions When one-touch type mounting bracket is used When screw type mounting bracket is used (Fig ) Panel cutout (Fig ) nx Lateral close mounting n: Number of units mounted (Fig. 8.-1) 1
14 8. Current transformer (CT) dimensions CTL--S (for 20A) 8.5 Mounting When the one-touch type mounting bracket is used: Mounting panel thickness is 1 to mm. Set the mounting bracket 1 to the top and bottom of the instrument first. Then, insert the GCS-00 2 from the front of the mounting panel. When the Soft-type Front-cover is applied, mounting panel thickness is 1 to 2.5mm. (Fig. 8.-1) (Fig ) CTL-12-S-10L1 (for 50A) 2 1 UP When the screw type mounting bracket (option [BL]) is used: Mounting panel thickness is 1 to 15mm. Insert the GCS-00 from the front of the panel. Attach the mounting bracket by the holes at the top and bottom of the case, and secure the unit in place with the screws. When the Soft-type Front-cover (FS-8-S) is applied, mounting panel thickness is 1 to 1.5mm. 1 Up Up (Fig ) Notice As the case is made of resin, do not use excessive force while screwing in the mounting bracket. The torque is approximately 0.12N m. 1
15 9. Terminal arrangement Warning Turn the power supply to the instrument before wiring or checking. Working or touching the terminal with the power switched may result in severe injury or death due to Electric Shock. 100 to 20V AC or 2V AC/DC A1 A2,LA or W CT input SM (Fig. 9-1) RS-85 YA(-) YB(+) COM R/ TC A B B + S/ or A/ RTD R/ : Relay contact output S/ : Non-contact voltage output A/ : Current output A1 : Alarm 1 (A1) A2 : Alarm 2 (A2) W : Heater burnout alarm LA : Loop break alarm SM : Setting value memory (external selection) RS-85 : Serial communication Dotted lines: Option Notice The terminal block of the GCS-00 is designed to be wired from the left side. The lead wire must be inserted from the left side of the terminal, and fastened with the terminal screw. Use a thermocouple and compensating lead wire in accordance with the input specification of this controller. Use a -wire system of RTD according to the input specification of this controller. This controller has neither built-in power switch nor fuse. Therefore, it is necessary to install them in the circuit near the external controller. (Recommended fuse: Time-lag fuse, rated voltage 250V, rated current 2A) In the case of 2V DC for power source, do not confuse the polarity. With the relay contact output type, externally use an auxiliary electromagnetic switch in accordance with the capacity of the load to protect the built-in relay contact. When wiring, keep input wire (thermocouple, RTD, etc.) away from AC source and load wire to avoid external interference. Solderless terminal Use a solderless terminal with an isolation sleeve in which an M screw fits as shown below. 5.8mm or less φ.2mm 5.8mm or less.2mm Solderless terminal Y type Round type (Fig. 9-2) Manufacturer Model name Tightening torque Nichifu Terminal Industries CO., LTD. 1.25Y- Japan Solderless Terminal MFG CO., LTD. VD1.25-BA Nichifu Terminal Industries CO., LTD Japan Solderless Terminal MFG CO., LTD. V N m, Max. 1.0N m 15
16 Option: Heater burnout alarm output (1) This alarm is not available for detecting current under phase control. (2) Use the current transformer (CT) provided, and pass a lead wire of the heater circuit into the hole of the CT. () When wiring, keep the CT wire away from any AC sources or load wires to avoid the external interference. CT 11 CT input 12 terminal Power source (Fig. 9-) 10. Specifications 10.1 Standard specifications Mounting method : Flush Setting : Input system using membrane sheet key Display PV display : Red LED display digits, size, 5.5(W) x 10(H) mm SV display : Green LED display digits, size, (W) x 8(H) mm Accuracy (Setting and Indication) Thermocouple : Within 0.% of input range full scale 1digit, or within 2 ( ), whichever is greater RTD : Within 0.2% of input range full scale 1digit, or within 1 (2 ), whichever is greater Input sampling period: 0.25 seconds Input Thermocouple RTD Heater : K, J, E External resistance, 100 or less When input abnormal, Overscale : Pt100, JPt100 -wire system Allowable input lead wire resistance, 10 or less per wire When input abnormal, Overscale Control output Relay contact : 1a Control capacity, 250V AC A (resistive load) 250V AC 1A (inductive load cosø=0.) Non-contact voltage : For SSR drive V DC Maximum 0mA (short circuit protected) 0 If Shinko SSR (SA-200 series) is used, units are connectable in parallel. Current : to 20mA DC Load resistance, maximum 550 Alarm 1 (A1) output Action : / action, 0.1 to 99.9 ( ) Output : Relay contact, 1a Control capacity, 250V AC A (resistive load) 250V AC 1A (inductive load cosø=0.) Control action PID action (with auto-tuning function) PD action (with auto-reset function) (When setting the integral time to 0.) Proportional band : 0 to 999 ( ) or 0.0 to 99.9 (/ action when set to 0 or 0.0) Integral time : 0 to 999s (off when set to 0) Derivative time : 0 to 00s (off when set to 0) Proportional cycle : 1 to 120s (not available for the current output type) ARW : Automatic Output limit : 0 to 100% ( 5 to 105% for the current output type) / action (When setting proportional band value to 0 or 0.0.) : 0.1 to 99.9 ( ) 1
17 Circuit isolation configuration 1 2 COM A1 Power source Alarm 1 (A1) Isolated Serial communication Settig value memory (external selection) CT input CPU Input * Output A2 5 Alarm 2 (A2) or Heater burnout alarm * In the case main output type is Current output or Non-contact voltage output, Output is not isolated from Input, and Output is not isolated from CT input. Isolation resistance 10M or greater at 500V DC In the case of the above circuit isolation configuration (*), the resistance isolation test must not be carried out between Output and Input, and between Output and CT input because Output and Input, and Output and CT input are not isolated. Dielectric strength Between input terminal and ground. 1.5kV AC for 1 minute Between input terminal and power terminal 1.5kV AC for 1 minute Between output terminal and ground 1.5kV AC for 1 minute Between output terminal and power terminal kV AC for 1 minute Between power terminal and ground 1.5kV AC for 1 minute Supply voltage : 100 to 20V AC, 50/0Hz, 2V AC/DC, 50/0Hz Allowable voltage fluctuation: 100 to 20V AC: 85 to 2V AC 2V AC/DC : 20 to 28V AC/DC Power consumption : Approx. 8VA Ambient temperature : 0 to 50 (2 to 122 ) Ambient humidity : 5 to 85%RH (non-condensing) Weight : Approx. 10g External dimensions : 8 x 8 x 9.5mm (W x H x D) Material : Flame resistant resin (case) Color : Light gray (case) Attached functions : Control output function Setting value lock Sensor correction Power failure countermeasure Self-diagnosis Automatic cold junction temperature compensation Sensor burnout Input abnormality indication Accessories : One-touch type mounting bracket 1 set (When the option [BL] is applied, Screw type mounting bracket 1 set) Instruction manual 1 copy Terminal cover 1 piece (when option [TC] is applied) Current transformer 1 piece CTL-S: When option W (5A, 10A, 20A) is applied CTL-12-S-10L1: When option W (50A) is applied 1
18 10.2 Optional specifications Alarm 2 (A2) output [Option code: A2] The option [SM] or [W] cannot be applied in conjunction with this option. When this option is applied together with option [LA], they share output terminals. Action : / action, 0.1 to 99.9 ( ) Output : Relay contact, 1a Control capacity, 250V AC A (resistive load) 250V AC 1A (inductive load cosø =0.) Heater burnout alarm output (including sensor burnout alarm) [Option code: W] Watches the heater current with CT (current transformer), and detects the burnout. The option [A2], [SM] or [C5] cannot be applied in conjunction with this option. This option cannot be applied to the current output type. Rating : 5A [Option W(5A)], 10A [Option W(10A)], 20A [Option W(20A)] or 50A [Option W(50A)] (Must be specified) Setting range : In the case of 5A [W(5A)], 0.0 to 5.0A (off when set to 0.0) In the case of 10A [W(10A)], 0.0 to 10.0A (off when set to 0.0) In the case of 20A [W(20A)], 0.0 to 20.0A (off when set to 0.0) In the case of 50A [W(50A)], 0.0 to 50.0A (off when set to 0.0) Setting accuracy: Within 5% of the rated value Action Output : / action : Relay contact, 1a Control capacity, 250V AC A (resistive load) 250V AC 1A (inductive load cosø =0.) Serial communication [Option code: C5] The option [SM], [LA] or [W] cannot be applied in conjunction with this option. The following operations can be executed from the external computer. (1) Reading and setting of the main setting value, PID values and various setting values (2) Reading of the input value and action status () Change of the functions Communication line : Based on EIA RS-85 Communication method : Half-duplex communication start-stop synchronous Communication speed : 200, 800, 900 and 19200bps (selectable by keypad) Data format : Start bit 1 Data bit Parity Even Stop bit 1 Digital external setting : Receives digital setting value from the PC-900 [option: SVTC]. The Setting value lock of the GCS should be set to Lock. Setting value memory (external selection) [Option code: SM] If this option is applied, Main setting value 1 or Main setting value 2 can be selected by external contact. The option [A2], [C5], [LA] or [W] cannot be applied in conjunction with this option. Multi-range [Option code: MR] This option cannot be applied to the thermocouple K type whose rated scale is 0 to 00. Sensor selection: Thermocouple (K, J, E) or RTD (Pt100, JPt100) Temperature unit: or Loop break alarm [Option code: LA] The alarm is activated when the process variable (PV) does not change as much value as the setting span or greater within the time it takes to assess the loop break alarm after the manipulating variable reaches the maximum value or the minimum value. Also, this detects heater burnout, sensor burnout and actuator trouble. The option [C5], [SM] or [W] cannot be applied in conjunction with this option. When this option is applied together with option [A2], they share output terminals. Setting range: Loop break alarm time: 0 to 200 minutes Loop break alarm span: 0 to 150 ( ) Output: Relay contact, 1a Control capacity, 250V AC A (resistive load), 250V AC 1A (inductive load, cosø=0.) Color black [Option code: BK] Front panel : Dark gray Base and case : Black 18
19 Screw type mounting bracket [Option code: BL] Mounting panel thickness: 1 to 15mm Dust-proof Drip-proof [Option code: IP] Dust-proof and Drip-proof specification (IP5) Effective only for panel surface, case part is excluded. Front cover (soft type, sold separately) is recommended to strengthen the Dust-proof and Drip-proof specification. To protect the controller from water leak between the control panel and controller, the control panel surface to be mounted should be vertical. Terminal cover [Option code: TC] Electrical shock protection terminal cover Designated specifications Input and scale range : Shipped as designated input and scale range Alarm action : Shipped as designated alarm action Control action : Shipped as designated control action (e.g. shipped as PD action) : Shipped as designated hysteresis Cooling (Direct) action : Shipped as Cooling (Direct) action 11. Troubleshooting If any malfunctions occur, refer to the following items after checking the power supply and wiring. <Indication> Problem The PV display is indicating. is flashing on the PV display. is flashing on the PV display. The indication of the PV display is abnormal or unstable. Presumed cause and solution Control output function is working. To release the function, press the key for approx. 1 second. Thermocouple or RTD is burnt out. [Thermocouple] If the input terminal of the instrument is shorted, and if a value around room temperature is indicated, the instrument is likely to be operating normally, however, the sensor may be burnt out. [RTD] If approximate 100 of resistance is connected to the input terminal between A-B of the instrument and between B-B is shorted, and if approximate 0 (2 ) is indicated, the instrument is likely to be operating normally, however, the sensor may be burnt out. Check whether the lead wire of thermocouple or RTD is securely connected to the instrument terminal. Check whether the polarity of thermocouple or compensating lead wire is correct. Check whether codes (A, B, B) of RTD agree with the instrument terminals. Check whether the sensor input is selected properly. Check whether the temperature unit ( or ) is correct. Check whether the sensor correction value is suitable. Check whether the specification of the thermocouple or RTD is proper. AC leaks into the thermocouple or RTD circuit. There may be equipment that interferes with or makes noise near the controller. 19
20 <Key operation> Problem Unable to set the SV, P, I, D, proportional cycle, alarm setting, etc. The values do not change by the or key. The setting indication does not change within the rated scale range even if the or key is pressed, and unable to set the value. <Control> Problem The process variable (PV) does not rise. The control output remains in an status. The control output remains in an status. Presumed cause and solution Setting value lock (Lock 1 or Lock 2) has been designated. Release the lock mode. During PID auto-tuning or auto-reset. In the case of PID auto-tuning, cancel auto-tuning. In the case of Auto-reset, it takes approximate minutes until the auto-reset is completed. Main setting value high limit or low limit may be set at the point where the value does not change. Set it to a suitable value during Auxiliary function setting mode 1. Presumed cause and solution Check whether thermocouple or RTD is burnt out. Check whether the lead wire of thermocouple or RTD is securely connected to the instrument terminal. Check whether the output wiring is securely performed. Output low limit setting value is set to 100% or greater in Auxiliary function setting mode 2. Set it to a suitable value. Output high limit setting value is set to 0% or less in Auxiliary function setting mode 2. Set it to a suitable value. For any inquiries about this unit, please contact the agent or us. SHINKO TECHNOS CO.,LTD. OVERSEAS DIVISI Reg. Office : 2-8, 1-Chome, Ina, Minoo, Osaka, Japan Mail Address : P.O.Box 1, Minoo, Osaka, Japan URL : overseas@shinko-technos.co.jp Tel : Fax:
Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100
INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.
More informationJIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.
INSTRUCTION MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E3 24.7 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY
More informationINSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A
INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A Preface Thank you for the purchase of our Microcomputer based Temperature Indicating Controllers JCD-13A or
More informationINSTRUCTION MANUAL Micro-computer based digital indicating controller
INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution
More informationInstruction manual Micro-computer based digital indicating controller
Instruction manual Micro-computer based digital indicating controller JCS-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual.
More informationJIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.
INSTRUCTI MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E6 28.8 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY
More informationInstruction manual for DIN rail mounting type indicating controller DCL-33A
Instruction manual for DIN rail mounting type indicating controller DCL-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution
More informationINSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200
INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 PV PV AT AT OUT1 OUT2/HB A1 A2 OUT1 OUT2/HB A1 A2 MODE OUT MODE OUT GCD GCR Preface Thank you for the purchase
More informationInstruction manual Temperature Controller KT7
Instruction manual Temperature Controller KT7 No. KT71E7 201.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure
More informationDCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER DCL-A No.DCL1E5 200.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY
More informationDIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL
DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL Preface Thank you for purchasing our Digital indicating controller FCS-23A. This manual contains instructions for the mounting, functions, operations
More informationINSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A
INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions
More informationINSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K
INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT PREFACE Thank you for your purchase of our Touch panel monitoring unit. This manual contains instructions for the mounting, functions, operations and
More information1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.
INSTRUCTI MANUAL (EXCERPT) Digital Indicating Controller ACS-13A- /A (For Use with the Infrared Temperature Sensor RD-500) No.ACS11AE1 2011.07 The digital indicating controller ACS-13A /A is an exclusive
More informationDIGITAL INDICATOR JIR-301-M
DIGITAL INDICATOR JIR-301-M Instruction Manual Preface Thank you for purchasing our digital indicator JIR-301-M. This manual contains instructions for the mounting, functions, operations and notes when
More informationWarning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER
INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER 1 DCL-A DC No.DCLDCE1 2007.01 Thank you for purchasing our DIN rail mounting type indicating controller DCL-A DC. This manual contains instructions
More informationDIGITAL INDICATOR DI25
DIGITAL INDICATOR DI25 Operating instructions Preface Thank you for purchasing our digital indicator DI25. This manual contains instructions for the mounting, functions, operations and notes when operating
More informationDIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL
DIN RAIL MOUNTED INDICATING CONTOLLER DCL-A INSTRUCTION MANUAL Preface Thank you for purchasing our DIN rail mounted indicating controller DCL-A. This manual contains instructions for the mounting, functions,
More informationISOLATOR SGI SGIW INSTRUCTION MANUAL
ISOLATOR SGI SGIW INSTRUCTION MANUAL Preface Thank you for purchasing our SGI, SGIW or SGIL, Isolator. This manual contains instructions for the mounting, functions, operations and notes when operating
More informationDIGITAL INDICATING CONTROLLER. BCx2 INSTRUCTION MANUAL
DIGITAL INDICATING CONTROLLER BCx2 INSTRUCTION MANUAL Preface Thank you for purchasing our digital indicating controller BCx2 (BCS2, BCR2, BCD2). This manual contains instructions for the mounting, functions,
More informationNo.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.
Instruction manual Hygrothermo transmitter THD-500 Series No.THD51E1 2001.11 To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual. Notes This
More informationCommunications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03
Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications
More informationSeries Temperature Controller Instruction Sheet
Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep
More informationUniversal controller for panel mounting Models CS6S, CS6H, CS6L
Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing
More informationPLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL
PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL PREFACE Thank you for the purchase of our PLC Interface Unit CIT-200. This manual contains instructions for the mounting, functions, operations and notes when
More informationTEMPERATURE CONTROLLER
TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response
More informationWarning Caution. Safety Precautions (Be sure to read these precautions before using our products.)
INSTRUCTION MANUAL Infrared Temperature Sensor RD-715-HA No. RD71JE1 2013.09 Preface Thank you for purchasing our Infrared Temperature Sensor RD-715-HA. This manual contains instructions for the mounting,
More informationCommunications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)
TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and
More informationSafety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.
Temperature Controller KXN Series INSTRUCTION MANUAL Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product. Please check whether the prouduct you purchased is the exactly same as you ordered. Before using
More informationF4 Process Controller Installation and Operation Guide
F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance
More informationMICRO CONTROLLER S Z SERIES
Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure
More informationHigh Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.
High Resolution Temperature Controller REX-F9000 Instruction Manual RKC INSTRUMENT INC. IM9000F01-E5 All Rights Reserved, Copyright 1999, RKC INSTRUMENT INC. Thank you for purchasing this RKC product.
More informationMICRO CONTROLLER E Z SERIES
Instruction Manual MICRO CONTROLLER E Z SERIES TYPE: PYZ 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN2PYZDe-E INTRODUCTION You are now the owner of Fuji's Digital Temperature Controller. Before using, be sure
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationMicro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e
C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationSA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail
Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as
More informationTemperature Controller
E5AN Temperature Controller Temperature Controller OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Measuring Components Department Shiokoji Horikawa, Shimogyo-ku,
More informationUDC 700 Universal Digital Controllers and Indicator Specifications
UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality
More informationenproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl
enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring
More informationSA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting
Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller
More informationTempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications
Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates
More informationCN4800 Series CONTROLLER
CN4800 Series CONTROLLER Operator's Manual PV SV OUT1 OUT2 ALM1 ALM2 SEL M1791/0502 Contents I. PREPARING THE OPERATION... 4 1. THE BASIC INSTALLATION PROCEDURE... 5 2. CHECK OF SPECIFICATIONS... 6 2.1
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationTEMPERATURE CONTROL MODULE MODEL R3-TC2
INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...
More informationCB103/CB403/CB PRODUCT CHECK 2. MOUNTING - * - / /Y INSTRUCTION MANUAL WARNING. 2.1 Mounting Cautions CAUTION RKC INSTRUMENT INC.
Digital Controller CB/CB4/CB9 INSTRUCTI MANUAL IMCBE7 Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of your new instrument, carefully read
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationVERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER
1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning
More informationSR70 (SR ) Series Digital controller Instruction Manual
SR70 (SR71 72 73 74) Series Digital controller Instruction Manual Thank you for purchasing the Shimaden SR70 Series. Please check that the delivered product is the correct item you ordered. Please do not
More informationTempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications
Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates
More informationSeries Digital Controller Instruction Sheet
216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure
More informationCommunications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02
Temperature Controller Fuzzy Self-tuning Temperature Controller with Advanced PID (2-PID) Control DIN-size: 6 x 6 mm (E5AJ), 2 x 2 mm (E5BJ), 4 x 4 mm (E5CJ), 4 x 6 mm (E5EJ) Fuzzy self-tuning and Auto-tuning
More informationARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER
ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationR Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p
The first edition contrasted April 2011 Yamamoto Electric Works Co.,Ltd. T H E G E N E R A L C A T A L O G R We appreciate the importance of air. Manostar gage h t t p : / / w w w. m a n o s t a r. c o.
More information1. PRODUCT CHECK 2. MOUNTING - * - / /Y
Digital Controller /CB/CB/CB/CB9 ISTRUCTI MAUAL IMCB-E Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of your new instrument, carefully read
More information1. PRODUCT CHECK 2. MOUNTING
Digital Controller /CB/CB/CB/CB ISTRUCTI MAUAL IMCB-E Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of your new instrument, carefully read
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More information4TEMPERATURE CONTROLLER
Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and
More informationMulti-point Digital Controller MA900/MA901. Initial Setting Manual IMR01H03-E4 RKC INSTRUMENT INC.
Multi-point Digital Controller MA900/MA901 Initial Setting Manual RKC INSTRUMENT INC. IMR01H03-E4 !"Modbus is a registered trademark of Schneider Electric.!"Company names and product names used in this
More informationNov 08 PRODUCT SPECIFICATION SHEET
Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN
More informationDigital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)
Digital Panel Meter Low-cost, High-quality Digital Thermometer with Built-in Microcomputer Compact DIN-size (96 x 48 x 66 (W x H x D)) body. Mounting thickness of only 3.5 mm required. Highly visible display
More informationUDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationInterchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F
Temperature Controller 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes Accurate to ±0.5% of full scale Multiple temperature scale ranges allow flexibility to match application Field-selectable
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable
More informationGeneral Specifications
General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.
More informationSerie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)
Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /
More informationSA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection
SA00 SA00 SA00 SA00 Temperature Limit ontroller SA00L FM APPROVED SA00L General Description The SA00L is a FM approved high limit or low limit controllers. The SA00 is a socket mounting type temperature
More informationAE500 Instruction Manual
Digital Indicator with Alarm function AE500 Instruction Manual IMAE01-E8 Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of your new instrument,
More informationTemperature Controller SA100. Initial Setting Manual IMR01J03-E1 RKC INSTRUMENT INC.
Temperature Controller SA100 Initial Setting Manual RKC INSTRUMENT INC. IMR01J03-E1 Modbus is a registered trademark of Schneider Electric. Company names and product names used in this manual are the trademarks
More informationE5CN Temperature Controller User s Manual
E5CN Temperature Controller User s Manual Revised July 2003 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in
More informationHardware Instruction Manual. SR Mini HG SYSTEM. High-performance Multi-point Control System IMSRM15-E4 RKC INSTRUMENT INC.
SR Mini HG SYSTEM High-performance Multi-point Control System SR Mini HG SYSTEM Hardware Instruction Manual RKC INSTRUMENT INC. RKC www.rkc-usa.com Distributed By (800) 576-6308 Inc, IMSRM15-E4 All Rights
More informationModel 96VTR ¼ DIN Process Controller
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 96VTR Product Info Page INSTRUCTION MANUAL Model 96VTR ¼ DIN
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 48VTR Product Info Page Instruction Manual English / Español
More informationDigital Heater Element Burnout Detector K8AC-H
Digital Heater Element Burnout Detector K8AC-H A high-precision Heater Element Burnout Detector compatible with a wide-range of heater control methods. Push-in terminals reduce the workload. *1 Scaling
More informationTC515 and TC600 Installation Manual. a Winters company
THERMOLINE TEMPERATURE CONTROLLERS TC515 and TC600 Installation Manual a Winters company Guarantee 12 months Congratulations on the purchase of this new product. Special care with the design, workmanship
More informationUDC100 Universal Digital Controller Specifications
UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines
More informationSpecification , July 2015
Technical Information PrecisionLine Controllers EDC21 / EDC22 / EDC23 EASYSET DIGITAL CONTROLLERS Specification 51-52-3-48, July 215 Introduction The EDC21, EDC22 and EDC23 controllers provide precise
More informationINSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:
INSTRUCTION MANUAL Laboratory Equipment Pty Ltd email: sales@labec.com.au Ph: 02 9560 2811 Fax: 02 9560 6131 www.labec.com.au 2014 Shaking Water Bath Instruction Manual Model : J-SWB19, J-SWB35, J-SWB60
More information370, boulevard de Balmont LYON Tel Fax Web:
AUTOMATISME Régulateurs de température delta DELTA développe, dessine, fabrique des composants et des équipements électronique pour les plus importants constructeurs internationaux. Fort de ses 30.000
More informationMODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power
Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function
More informationDigi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with
More informationAdvanced Ultraviolet Burner Controller
No. CP-SS-7E Advanced Ultraviolet Burner Controller Model AUR300C/AUR30C Overview The AUR300C Advanced Ultraviolet Burner Controller and AUR30C Advanced Ultraviolet Burner Controller with Communication
More informationDigital Panel Meters 47 Series. DC INPUT DIGITAL PANEL METER (4 1/2 digit, LED display type) Model: 47LV OPERATING MANUAL
Digital Panel Meters 47 Series DC INPUT DIGITAL PANEL METER (4 1/2 digit, LED display type) Model: 47LV OPERATING MANUAL 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax:
More information7EF/7HF/7EC/7ES Temperature Controllers
7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent
More information+ A B V B NO NC V COM PV PV
+ - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC
More information(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA
TC3YF Freezing/ type DIN W72 H36mm Freezing/ type Features ON/ Control Input specification - Basic specification: NTC(Thermistor), Option: RTD(DPt100Ω) Temperature display range NTC type: -40.0 to 99.9
More informationPID Temperature Controller. ITC-100 User Manual. Version 2.0s. Inkbird Tech. Co., Ltd.
PID Temperature Controller ITC-100 User Manual Version 2.0s Copyright Copyright 2016 All rights reserved. No part of this document may be reproduced without prior written permission. Disclaimer Inkbird
More informationSR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC.
SR Mini HG SYSTEM High-performance Multi-point Control System SR Mini HG SYSTEM Hardware Instruction Manual RKC INSTRUMENT INC. IMSRM15-E6 Modbus is a registered trademark of Schneider Electric. The name
More informationVERTEX F4 Instruction Manual
VERTEX F4 Instruction Manual 02/2018 The VERTEX F4 controller 1/16 DIN is our LOW COST yet HIGH SPEC controller. Configurable on input between various thermocouples from the keypad by the user or when
More informationLA type soldering iron controller
PATRIOT M12 LA type soldering iron controller Instruction manual (User s manual) Preparation in July. 2013 The 7th edition JAPAN BONKOTE CO., LTD. Contents 1 Preface 1 2 Notes for safety 1 3 Auto-tuning
More informationCONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual
Instruction Manual Micro-controller X Model : PXR5/9 INP-TNPXR5/9-E Head Office -, Osaki -chome, Shinagawa-ku, Tokyo, 4-3 Japan Sales Div. International Sales Dept. No., Fuji-machi, Hino-city, Tokyo, 9-85
More informationAutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.
AutomationDirect 1/16 DIN Series Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution
More informationAnyWireASLINK System Products Guide
READER/WRITER MADE IN JAPAN System Products Guide S-K1117 -M -3012 is a registered trademark of OMRON Corporation. [Notes on Safety] Precautions that must be observed in order to use this system safely
More informationSYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1
SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 Jun. 2007 Auber Instruments, 730 Culworth, Alpharetta, GA 30022 www.auberins.com e-mail: auberins@gmail.com Tel: 404-291-6298 WARNING
More informationOakton TEMP 9500 Advanced Multiparameter Controller
Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents
More informationUDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 11/98 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 & UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers which
More informationOriginal instructions. Operation Manual & Cautions
Original instructions Operation Manual & Cautions Thank you for purchasing the Mistresa from Showa Denki. This manual explains the specifications for the [Mistresa units from CRN Series]. Please read the
More informationTable of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage
Table of Contents 1 Features 2 Setup 3 Cautions 4 Description of the parts 5 Temperature Controls 6 Maintenance and Storage 7 Troubleshooting 8 Warranty 9 Technical Specifications -2- Safety warnings Before
More informationCONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual. INP-TN1PXR5/9f-E
Instruction Manual Micro-controller X Model : PXR5/9 INP-TNPXR5/9f-E International Sales Div Sales Group Gate City Ohsaki, East Tower, -, Osaki -chome, Shinagawa-ku, Tokyo 4-, Japan http://www.fujielectric.com
More information