Installation, Operation and Maintenance Instructions

Similar documents
Installation, Operation and Maintenance Instructions

FB-310A. Removes Chips, Sludge & Solids with Minimal Downtime

Tramp Oil. Removal Equipment Equipment designed for removing oil from water based fluids ERIEZ. ...Only from Eriez. Tramp Oil. Removal Equipment:

Installation, Operation and Maintenance Instructions

Metalarm Metal Detectors. Model TR, BR, PL, PL2 and VC and HH-10 ERIEZ. ...Only from Eriez. Features:

TrusT EriEz To protect your customers and brand image

Fluid Management. Comat Superfiltration System

SCRAP DRUMS (PERMANENT OR ELECTRO-MAGNETIC)

INTRODUCTION / TABLE OF CONTENTS

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

5HP CYCLONE DUST COLLECTOR MANUAL

Submittal Packages Detailed with Items and Reviewers

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Metalworking Fluid Recycling

7165 Dust Collector Owner s Manual

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Number (SIN)

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Sprinkler Identification Numbers

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

MODEL PR16 POWER ROTARY

High gradient magnetic separators Continuous HGMS. Recover particles down to extremely fine sizes

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

Helically wound resistance wire coil made

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

SERVICE PARTS/OPERATION for

Flanged Immersion Heaters

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

INSTALLATION INSTRUCTION

Installation and servicing instructions

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

Flanged Immersion Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

Flanged Immersion Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

General System Layout Sketch

Micro-Computer Induction Cooktop SR-1885SS

Operator s Manual. Mirage. Buffet Induction Warmers

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

2HP MOBILE CYCLONE DUST COLLECTOR MANUAL

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

Models Series Series

Models Series Series

UNIVERSAL SOLVENT HEATER

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

Technical Specifications & Pricing

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

254 Nanometer Germicidal UV Disinfection Systems

REVERSE OSMOSIS SYSTEMS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

! WARNING. Before using product, read and understand instructions.

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Sprinkler Identification Numbers

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

SuperKlean Washdown Products

Installation Instructions

690 Power Fishing System

Injection Molding Cold Runner/Conventional Resin or Color Change: Performance Tips

Installation Instructions

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

General System Layout Sketch

Injection Molding Hot Runner Systems Resin or Color Change Mold Closed: Performance Tips

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

FB-101. Fluid Management Product Selection Guide

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

P/N CC-100. Coolant Circulator. Operation manual

Commercial/Industrial Combustion Control Level Three Announcement

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

INSTALLATION INSTRUCTIONS

Installation Instructions

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

DIRTCAL - DIRTMAG dirt separator

Transcription:

MMPM-440D Installation, Operation and Maintenance Instructions HIGH InTENSITY Magnetic Filter ERIEZ MAGNETICS HEADQUARTERS: 2200 ASBURY ROAD, ERIE, PA 16506 1402 U.S.A. WORLD AUTHORITY IN SEPARATION TECHNOLOGIES 1 High Intensity (Model HI) Magnetic Filters

Introduction This manual details the proper steps for installing, operating and maintaining the Eriez High Intensity (Model HI) Magnetic Filters. Careful attention to these requirements will assure the most efficient and dependable performance of this equipment. If there are any questions or comments about the manual, please call Eriez at 814/835-6000 for assistance. 2017 ERIEZ MAGNETICS ALL RIGHTS RESERVED 2

Table of Contents ERIEZ MODEL HI FILTERS GENERAL...4 INSTALLATION...5 ELECTRICAL...5 OPERATION...6 MAINTENANCE...7 3 High Intensity (Model HI) Magnetic Filters

General Eriez High Intensity Filters have evolved into an extensive and highly technical product line. The basic electro and permanent filters operate at about 1,500 gauss. Additional models have been added to the line, providing fields up to and be yond 10,000 gauss. Although any field intensity may be supplied, there are several design points with basic characteristics as follows: 1,500 gauss: These units have dry potted coils and generally require no special cooling, or may use permanent magnets. 2,500 gauss: These units may have dry potted coils, but are generally filled with a transformer oil. If not, a highly thermally conductive epoxy is used to fill the magnet case. available that generate magnetic fields up to 50,000 gauss. Superconducting de signs may be economically justified at fields above 20,000 gauss and should be considered. Standard filters are sized based on nominal ca pacity with water. The available capacities are 10, 25, 50, 100, and 200 gallon per minute (GPM). Model designations are based on ca pacity and field strength. For example a 25-15 is a twenty-five GPM, 1,500 gauss unit A P suffix, such as 25-15P indicates a permanent magnet source. Capacity of filters varies according to the viscosity or percent solids of the slurry. Capacity of your filter has been selected based on the specific material to be processed. 5,000 gauss: These units are oil filled and include a pump and heat exchanger. 10,000 gauss: These units require a hollow conductor coil with coolant passed directly through the wire. Although filters with magnetic fields higher than 10,000 gauss are known as High Gradient Mag netic Separators, the magnetic design principles remain the same. Hollow conductor wire coils may be used to generate magnetic fields up to 25,000 gauss. Beyond that, superconducting magnets are Figure 2 EXPANDED METAL MATRIX The matrix performs the separating function of the magnet Standard filter assemblies consist of a stack of 400 series stainless steel (ferromagnetic) expanded metal plates. Other matrices may be made of screen cloth, steel wool or steel balls. CAUTION: STRONG MAGNET This equipment includes one or more extremely powerful magnetic circuits. Steel and iron tools and other objects may be attracted suddenly and forcefully to the magnets, creating the risk of serious pinchtype injuries. Keep all mild steel and iron tools and equipment well away from the magnets at all times. When handling the equipment, do not allow hands, fingers and other body parts to be caught between magnets and nearby steel or iron objects. If you use a heart pacemaker do not service or operate this equipment because the magnetic field may affect your pacemaker operation. Al ways stay at least 3 feet (1 meter) away from the magnetic components. Figure 1 TYPICAL 2,500 GAUSS HI FILTER The magnetic field may damage information stored on credit cards, computer disks, and other magnetic storage devices brought near the magnet. 4

Installation The HI Filter should be installed in an area which has a free flow of air. Ambient temperatures should average 70 F (21 C) and not consistently exceed more than 90 F (32 C). Air temperatures higher than this require special consideration and design. Process fluid temperatures should also not exceed this level. The electromagnets generate heat (all power consumption goes to heat) and heat trans fer to process fluids should be considered. Ther mal soaking where the magnet continues to release heat occurs for about four hours after power down. Process fluids remaining in the canister could be damaged by this heat. Electrical connections are very simple as shown in the following Figure 3. Provide adequate overhead clearance to remove the matrix when it becomes necessary. Case temperatures may exceed 175 F (80 C) and burns could be experienced with ACCIDEN TAL contact. Electrical Standard electromagnetic HI Filters are designed to operate from a 115 volt DC power source. A DC switch will be required if the unit is to be operated from an existing DC power source. This switch is to be used to energize or de-energize the filter. Always check to see that the filter is turned ON when it is in use. An ON condition is indicated by the proper current flow in addition to the voltage. If the filter is to operate from rectified AC current, no DC switch is needed. To turn the filter ON or OFF, simply make or break the AC current sup ply to the rectifier. This is by far the most com mon and preferred way of supplying and control ling power to the electromagnet. Figure 3 BASIC ELECTRICAL SCHEMATIC When connecting the power leads to terminals extra care must be taken. Two spark plug like terminals are available for connecting power leads. Two wrenches must be used when tight ening the nuts on the terminals. Torquing on the terminal could result in the breakage of the ter minal post or wire inside the magnet. An other wise unnecessary factory service call would be required to open and replace the terminal posts. The voltage for which the filter is wound is shown on the nameplate. Voltage more than ten per cent higher or lower than normal will affect the filter's operation. Over voltage may cause the coil to burn out. When voltage is low, the filter will not be operating at full strength. High Intensity (Model HI) Magnetic Filters 5

Installation (cont.) An electromagnet generates a magnetic field based on the amps and turns of wire in the coil. With a constant voltage control the amp draw will decrease as the coil heats and electrical resis tance rises. Normal drop in current to 70 per cent of cold is found with convectively cooled magnets. With force cooled (oil is pumped) mag nets a drop in current to about 85 percent of cold is expected. Monitoring of both voltage and cur rent to the magnet is useful to learn the normal operating conditions. A sudden and significant change from the normal operating conditions could indicate a partial coil failure. A DC control known as a constant current type is available when the magnet has been specially designed. In a constant current control the cur rent is maintained by increasing the voltage ap plied to the magnet It is not possible to retrofit a standard magnet with this feature. Permanent magnet Hi Filters require no external power source. Operation Standard HI Filter units are equipped with either an NPT threaded or 150 lb, class flanged inlet and outlet and the canister is rated at 150 psi. Batch feeding is possible with an optional bowl feed adapter in style B units. HI Filters are similar to other types of filters in that feed is processed for a period of time and then cleaned or backflushed. Filter capacity is based on the ability to remove magnetic contami nants, which is usually constrained by velocity. Rating capacity of a HI Filter varies from 7 to 150 GPM per square foot of filter area. Cleaning or backflushing time reduces the effective capacity of the filter. Time before backflush has varied from as little as 6 minutes to more than a day. For the basic bowl feed units the liquid is fed in at the top where it spreads out evenly and passes down through the filter stack, Cleaned material will flow out at the bottom of the filter. In the bowl-type units the normal cleaning method is by the removal of the matrix. The field must be shut off and then the matrix is removed and flushed with clean fluid. Permanent magnet units operate in the same way but the canister must be pulled through the mag net field. In the larger units it may be necessary to use a lever or small crane to pull the matrix. The other units have sealed canisters which utilize a pressure feed. Direction of the feed is often from the bottom up, allowing maximum dispersal in the matrix. When the velocity is higher, (>10 FPS or 3 MPS) the direction of flow does not have a significant impact on dispersal. Pressure feed units are often coupled with an automated valve system which allow timed sequencing of the feed and flush cycles. Figure 4 PERMANENT MAGNET BOWL TYPE HI FILTER A normal cycle involves filling the canister and continuous processing of material for a speci fied period of time. This time is determined from tests either on processed materials or in the laboratory, The objective of these tests is to determine the amount of time which passes before the breakthrough of the matrix occurs. Breakthrough may occur either with a sharply defined point or a steady increase in contami nant in the processed fluid. 6

Maintenance There are no moving parts requiring periodic mainte nance in the convectively cooled HI Filters. Abrasive materials will eventually wear down the sharp edges of the matrix. Should this occur, Eriez can sup ply a replacement having the same magnetic proper ties as the original. Force cooled units have heat exchangers and circu lating pumps which require periodic maintenance according to the supplied manufacturers literature. Oil cooled units should be periodically checked for a dielectric breakdown in the transformer oil (minimum 20 kv). The local electric utility should be able to provide a source for this service. Refill the unit with same oil as on the magnet housing tag. An alternative point for flushing may occur when an increase in the pressure drop across the ma trix occurs. This is typically seen when large quantities of ferrous contamination are present. When the point for flushing the matrix is reached, feed is stopped and clear fluid is processed for one or two canister volumes. This minimizes the lost product which is in the canister and piping at backflush time. The magnet is then de-energized and a high velocity cleaning fluid is injected opposite the flow of the feed. For situations where the matrix is not easily cleaned the flushing di rection may be reversed one or more times. In jection of compressed air may improve cleaning by causing a scrubbing action. For especially difficult applications a demagnetization cycle may be built into the power supply. Automatic systems are available to control the entire feed cycle. Water cooled hollow conductor coils have a self moni toring deionizing system in the primary loop water path. The deionizing system would require the ion exchange tank to be periodically changed out. Figure 5 TYPICAL FORCED COOLING SYSTEM High Intensity (Model HI) Magnetic Filters 7

Note: Some safety warning labels or guarding may have been removed before photographing this equipment. Eriez and Eriez Magnetics are registered trademarks of Eriez Manufacturing Co, Erie, PA 2017 Eriez Magnetics All Rights Reserved World Authority in Separation Technologies Headquarters: 2200 Asbury Road, Erie, PA 16506-1402 U.S.A. Telephone: 814-835-6000 Fax: 814-838-4960 Web Site: http://www.eriez.com e-mail: eriez@eriez.com Manufacturing Facilities: AUSTRALIA BRAZIL CANADA CHINA INDIA JAPAN MEXICO SOUTH AFRICA UNITED KINGDOM UNITED STATES 1117-AHA-Web ERIEZ MANUFACTURING CO 2017 PRINTED IN USA 8