TotalPac X Single interlock SUREFIRE system

Similar documents
TotalPac X Firecycle III Preaction Double interlock system

TotalPac 3 Firecyle III Deluge Remote controlled system

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

TotalPac 3 Wet pipe system c/w retard chamber

TotalPac 3 Single interlock Firecyle III Preaction Self-contained system

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

TOTALPAC2 Integrated Fire Protection System

TotalPac 3 Deluge, Electric release Self-contained system

TotalPac 3 Non interlock Preaction, Electric release Self-Contained system

TotalPac 3 Single interlock Preaction, Electric release Self-contained system

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

FireFlex DUAL Double Interlock, Self-contained system

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. 319a. January 27, 2012

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

TECHNICAL DATA OBSOLETE

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

Deluge & Preac tion Systems

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

BERMAD Fire Protection

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Deluge System. Pneumatic Release. Deluge System. Pneumatic Release

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Worldwide Contacts.

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

Model DDX Deluge Valve

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

TECHNICAL DATA. model c-2

TECHNICAL DATA OBSOLETE

Instructions for Installation, Operation, Care and Maintenance

Becoming an Expert on Dry-pipe, Preaction, and Deluge Sprinkler Systems

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

Operation & Maintenance Manual

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Options for Diesel Fire Pump Controllers

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Specification/ Data Sheet

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

CONSTRUCTION REQUIREMENTS

SECTION PREACTION SPRINKLER SYSTEMS

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Gas Station & C Store SECTION CWM Job No

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

FireFlex 1230 Self-contained system

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

Commercial and Light Industrial Fire Alarm Control Panel

OPEN SPRINKLER SYSTEM

SECTION SPRINKLER SYSTEMS

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

Discontinued Product

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

30.45 Electric Release PDRP-2001

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

TECHNICAL DATA. 31a. September 18, (DN25 - DN50)

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-10/(PGEN-10E)

Corrosion in Fire Sprinkler Systems Increasing Your Liability, Increasing Your Costs, and Shortening System Life

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

TECHNICAL DATA. 32a. September 18, /4-8 (DN32 - DN200)

FIRE-PAC SERIES 745 FIRELOCK SYSTEMS

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

SECTION DRY-PIPE SPRINKLER SYSTEMS

TECHNICAL DATA OBSOLETE

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

A. This section includes design and performance information for fire protection and suppression systems.

Series 759 FireLock Alarm Check Valve

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-3/(PGEN-3E) PGEN-5/(PGEN-5E)

ADDENDUM NO. 3 March 19, 2018

Wireless DC Voltage Detector

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

Box-in-Box Cold Storage Fire Protection Options

TECHNICAL DATA EASYPAC COMMERCIAL RISER MANIFOLD ASSEMBLIES 1-1/4-8 (DN32 - DN200)

Transcription:

DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a trim totally preassembled, pre-wired and factory tested. All electrical and mechanical components of the system are contained in one single unit TOTALPAC X SUREFIRE preaction systems are built around the Viking trim using deluge valves model E-3 for 1½" (40 mm) diameter and model E-1 for 2" (50 mm) diameter and up. SUREFIRE single interlock preaction systems use closed automatic sprinklers in the sprinkler piping. A detection network is used in parallel with the automatic sprinkler system and is designed to operate before a sprinkler head fuses. This network is electric and may be actuated by manual, fixed temperature, rate-of-rise temperature, smoke or other means. Detection system operates before the sprinkler fuses and gives an alarm. In fire conditions, when the detection system operates the system control panel (supplied by others) activates the deluge valve. The system piping is pneumatically pressurized to monitor the integrity of the piping, fittings and sprinklers and act as a failsafe emergency backup to the electrical detection system. The system piping is normally dry and may be installed in locations subject to freezing. Built in with special features to minimize accidental water damage, unlike other systems, it can be installed where the detector and/or sprinklers are easily damaged or broken accidentally. In addition to special features that offer perfect fail-safe modes, the Viking SUREFIRE Preaction Systems also provide excellent fire protection environment with or without electrical power. If a condition occurs that removes both the primary and secondary power supplies, the pneumatic actuator becomes the release mechanism and the system will operate as a dry pipe system. The SUREFIRE preaction system requires a VIKING VFR-400 control panel (supplied by others). All the valves are rated up to a maximum of 250 psi WWP (1724 kpa) max. and are available in the following diameters: 1½" (40 mm) 3" (80 mm) 6" (150 mm) 2" (50 mm) 4" (100 mm) Standard features NEMA 3 or NEMA 4 construction Factory assembled and tested under ISO-9001 standards Prewired to a terminal block Easy and compact installation Viking conventional trim rated at 250 psi (1724 kpa) Galvanized trim piping Serial number for easy reference Wide door for easy access Quarter turn door latches Lockable door to protect against tampering Lifting lugs provided for safe and easy handling Corrosion resistant paint finish Water supply and drain through the bottom center of the unit to avoid freeze-up potential Single drain connection 1 of 12 FM-076D-0-23C

Cabinet NEMA 3 Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure. NEMA 4 Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); and that will be undamaged by the external formation of ice on the enclosure. NEMA 3X Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure. NEMA 4X Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure. COMPARISON OF SPECIFIC NON-HAZARDOUS APPLICATIONS Type of enclosure Provide a degree of protection against the following environmental conditions 3 a 3X a 4 4X Incidental contact with enclosed equipment Rain, snow and sleet Hose down and splashing water Corrosive agents Ingress of solid foreign object (circulating or setting airborne dust, lint, fibers, and flyings) b Ingress of solid foreign objects (winblown dust, lint, fibers, and flyings) b a : these cabinet may be ventilated. b : these fibers and flyings are non hazardous materials and are not considered class III type ignitable fibers or combustible flyings. FM-076D-0-23C 2 of 12

Sequence of operation (see trim diagram) In a fire condition, when the detection condition is satisfied, system control panel (supplied by others) activates an alarm and energizes normally closed solenoid valve (F1) open. Pressure is released from the priming chamber of the deluge valve (A1) to the open drain manifold faster than it is supplied through the restricted orifice (B3). The Deluge Valve clapper opens to allow water to flow into the system piping and alarm devices, causing the alarm pressure switch (C1) and optional water motor alarm (C2) to activate. When a sprinkler head opens, water will flow from the system. When the deluge valve operates, the sensing end of the PORV (B9) is pressurized, causing the PORV to open. When the PORV opens, it drains the priming water pressure to the priming chamber, preventing the deluge valve (A1) from resetting, even if the open releasing devices close. The deluge valve can only be reset after the system is taken out of service, and the outlet chamber of the deluge valve and associated trim piping is depressurized and drained. Systems hydraulic limitations WARNING The information contained herewith is for estimation and evaluation purposes only. Its use remains the responsibility of the designer. Designers should refer to the appropriate NFPA Standards and any other applicable codes for their final design. Also refer to FireFlex Systems Inc. appropriate user manuals and to manufacturer's data sheets for additional details. Systems limitations indicated below are nominal flow limitations. Piping Equivalent Lengths w/o System size Usage Range shut off valve (in.) (gpm) (m.) (ft.) 1½ 0 200 8.6 28.2 2 0 330 12.9 42.3 3 125-700 19.8 64.8 4 250 1200 27 88.8 6 750-2800 31.2 102.4 3 of 12 FM-076D-0-23C

Standard equipment Deluge valve The Viking Model deluge valve is a quick-opening, differential diaphragm, flood valve with one moving mechanism. The deluge valve is used to control water flow in deluge and preaction sprinkler systems. The valve is held closed by system water pressure trapped in the priming chamber, keeping the outlet chamber and system piping dry. In fire conditions, when the releasing system operates, pressure is released from the priming chamber. The deluge valve clapper opens to allow water to flow into the system piping. Pneumatic actuator Used in conjunction with the solenoid valve, the Viking Pneumatic Actuator is a spring loaded, rolling diaphragm and piston operated valve. It is used wherever a combination is required between the detection and system s loss of air. Preaction riser check valve The Viking spring loaded In-Line check valve is a general purpose rubber-faced check valve approved for use in fireservice systems. The Spring Loaded In-Line check valve is manufactured with a brass body, brass seat, and a rubberfaced clapper assembly. Water supply control valve The Viking Easy Riser Swing check valve is a general purpose rubber-faced check valve approved for use in fire service systems. The valve is for use in preaction system risers. The water inlet control valve is a supervised, indicating butterfly valve. Purpose of this vale is to manually shutoff the preaction system. Solenoid valve The high pressure solenoid valve is a two-way type with one inlet and one outlet. It is a packless, internal pilot operated valve, suitable for use in releasing water pressure from the priming chamber of Viking deluge valves. The solenoid valve has floating diaphragm construction, which requires a minimum pressure drop across the valve to operate properly. IN OUT FM-076D-0-23C 4 of 12

Standard equipment (continued) Alarm pressure switch The alarm pressure switch monitors the water flow within the sprinkler piping. Should the Deluge Valve clapper opens to allow water to flow into the sprinkler piping. The alarm pressure switch will activate, indicating a water flow signal. POTTER PS10-1A Low air supervisory switch The low pressure switches monitors the pressure within the sprinkler piping should a loss pressure of the air below 25PSI occurs. The pressure switch contacts transfer indicating supervisory signal. Should a loss pressure of the air below 23PSI occurs. The pressure switch contacts transfer indicating alarm signal. POTTER PS40-1A 5 of 12 FM-076D-0-23C

Optional equipment Shut-off valve & sight glass option The Shut-off Valve & Sight Glass Option is intended to be used for applications where testing of the system operation without filling the sprinkler piping network is desirable and where it is critical that all functions of the preaction system be tested under actual discharge conditions. Shut-off valve (D4) Heater option Heater option is recommended where ambient temperatures can drop below 40 F (4.5 C). The cabinet s electric heater temperature cut-out point is set at 50 F (10 C). The heater option is equipped with a low temperature sensor that will activate a supervisory signal when temperature drops below 40 ±5 F (4.5 ±3 C). Heater option can be ordered in two supply voltage settings: 120Vac-60Hz. 400Watts. 220Vac-50Hz. 400Watts. Sight glass Point flashlight here Warning: TOTALPAC X cabinet is rated to provide freeze protection down to a minimum temperature of 14 F (-10 C). Insulated enclosure (standard with heater option) Insulation is made on foam core 2 thick R13 and have a foilfaced sheathing board composed of a uniform closed cell polyisocyanurate foam core bonded on each side to a triminate foil facer. One side has a foil reflective facer and the other side has a non-reflective foil facer. Low temperature sensor (standard with heater option) The low temperature sensor will close the normally open contact when the temperature drops below 40 F (4,5 C. The sensor will automatically reset to its normal state when the temperature rises above 40 F (4,5 C). Light option Optional fluorescent enclosure light is available for all cabinet configurations. Remote door switch activates the light when the door is opened. Light option can be ordered in two supply voltage settings: 120Vac-60Hz. 220Vac-50Hz. FM-076D-0-23C 6 of 12

Air supply Direct air compressor (Style A ) Used only for the sprinkler piping network of the preaction system. Air supply style "A" includes the air compressor mounted inside the TOTALPAC X cabinet with its supervisory trim and options. Compressors are of the tankless, oiless piston type and are factory piped to the sprinkler system riser, all within the TOTALPAC X cabinet. Air Pressure Maintenance Device (Style B ) Used only for the sprinkler piping network of the preaction system, when an external air supply is provided by others (tank mounted compressor, plant air or dry nitrogen cylinders) and piped to the air inlet port of the unit. Air supply style "B" provides an Air Pressure Maintenance Device (APMD) trim, factory mounted in the TOTALPAC X cabinet. Note: Direct air compressor is available only with NEMA 3, 3X cabinet. Compressors are available in four (4) sizes; 1/6HP 1/3HP 1/2HP 1HP Direct air, external compressor (Style D ) Mainly used with Preaction systems protecting refrigerated spaces and freezers, where a special dry external air supply unit is piped directly to the system riser inside the freezer itself, as shown in NFPA-13. Air supply Style "D" provides only an air supervisory and shut-off trim. Note: The external air supply must be restricted to insure that it cannot replace air as fast as it escapes when a releasing device or sprinkler operates. Air compressor selection Table: H.P. CFM @ 40 psi 120Vac System capacity (gallon) to Pump to 40 psi in 30 Minutes 220Vac System capacity (gallon) to Pump to 40 psi in 30 Minutes 1/6 1.33 110 90 1/3 2.61 215 170 1/2 4.06 335 270 1 7.40 610 400 Warning: When air supplies style "B" or "D" is selected, the air supply should be provided and installed by the sprinkler contractor OUTSIDE of the TOTALPAC X cabinet. It is NOT provided with the unit. Compressor Amp rating Compressor Size Amp. Rating at (HP) 120Vac 60Hz Amp. Rating at 220Vac 50Hz 1/6 6.6 A 3.3 A 1/3 6.6 A 3.3 A 1/2 8 A 4 A 1 12.4 A 6.2 A 7 of 12 FM-076D-0-23C

Details & field wiring diagrams Cabinet with main components, shown without door FM-076Z-0-43A FM-076D-0-23C 8 of 12

Trim diagram Components: A1 Deluge valve B1 Priming valve B2 Strainer B3 1/16" Restricted orifice B4 Spring loaded check valve B5 Alarm test valve B6 Flow test valve B7 Drip check valve B8 Drain check valve B9 Pressure operated relief valve (PORV) B10 Emergency release valve B11 Priming pressure water gauge & valve B12 Water supply pressure gauge & valve B13 Clapper check valve C1 C2 D1 D2 D3 E4 E9 F1 F2 F3 F4 F5 Alarm pressure switch Connection to water motor gong (strainer supplied by contractor) Water supply control valve Riser check valve Main drain valve Air supervisory pressure switch Float-check assembly N.C. Solenoid valve 24Vdc N.O. Solenoid valve 24Vdc Pneumatic actuator Pneumatic actuator pressure gauge 5/64" Restricted orifice 9 of 12 FM-076D-0-23C

Wiring diagram Waterflow Alarm switch TBA 1 2 3 4 TBB heater(optional) Light (optional) Very low air Alarm switch 5 6 7 8 M Low air Sup'v switch 9 10 11 12 Factory wired Main valve Sup'v switch 13 14 N.C. solenoid valve (See table below for details) 15 16 17 18 19 20 21 NOTES: - ALL DEVICES ARE SHOWN IN THEIR NORMAL SUPERVISORY STATE. - DRY CONTACTS RATINGS: PRESS. SWITCHES: 2.0A. 30VDC / 10A. 125/250 VAC SUPV. SWITCHES: 0.5A. 125 VDC /.025A. 250 VAC / 10A 125/250VAC USE ONLY WITH POWER LIMITED CIRCUITS - USE END-OF-LINE DEVICES COMPATIBLE WITH THE RELEASE CONTROL PANEL USED (NOT INCLUDED). N.O. solenoid valve (See table below for details) Low temperature Sup'v switch (optional) 22 23 24 25 26 Viking P/N Description Voltage Watts DC Amps 11591 SOLENOID VALVE ELECTRICAL RATINGS N.C. 24 Vdc 10 DC 416mA 11596 N.O. 24 Vcc 10 DC 416mA Pressure Rating 300 psi (2068 kpa) 300 psi (2068 kpa) Shut-off valve Sup'v switch (optional) 27 28 29 30 Notes: 1. Solenoid Valve is UL Listed as Fire Protection Special System Water Control Release Service (UL 429A Product category VLTR). 2. Voltage Drop: For proper operation, make sure that voltage at the solenoid valve is at least 85% of nameplate rating. 31 Factory wired 32 FM-076Z-0-33A FM-076D-0-23C 10 of 12

Dimensions B FACE VIEW S R A = Water inlet diameter B = Sprinkler riser diameter C = Drain diameter Q G SIDE VIEW K DRAIN - SCH.40 GROOVED OUTLET C WATER INLET SCH.40 GROOVED A M E O F D FM-076Z-0-54B L H N X J BOTTOM VIEW M O TOP VIEW V W NN Dimensions are nominal and may vary ±¼". Size A B C D E F G H J K L M N NN O Q R S T U V W X Y 1.5" 2" 1.5" 2" 50" 24.5" 14.5" 74" 11.5" 11" 68" 25" 5.5" 25" 25" 11" 60" 4.75" 6" 9.5" 10.5" 4" 5" 9.5" 7.75" 2" 2" 2" 2" 50" 23" 12" 74" 12" 11" 68" 25" 5" 25" 25" 11" 60" 4.75" 6" 9.5" 10.5" 4" 5" 9.5" 8" 3" 4" 3" 2" 50" 23" 12.5" 74" 8.5" 11" 68" 25" 5.5" 28.5" 22" 11" 60" 4.75" 6" 9.5" 10.5" 4" 5" 9.5" 8.5" 4" 4" 4" 2" 50" 22.5" 12.5" 74" 8" 12" 68" 25" 5.5" 25.5" 25.5" 12" 60" 4.75" 6" 9.5" 10.5" 4" 5" 9.5" 9" 6" 6" 6" 2" 50" 21" 12" 74" 8" 12" 68" 25" 5" 25" 25" 12" 60" 4.75" 6" 9.5" 10.5" 4" 5" 9.5" 9" 4.5" 4.5" 9/16" DIAM. (4 HOLES) 4.5" 4.5" FLOOR ANCHORING TEMPLATE 11 of 12 FM-076D-0-23C

1935, Lionel-Bertrand Blvd. Boisbriand QC Canada J7H 1N8 Tel.: 450-437-3473 Fax: 450-437-1930 Toll Free: 866-347-3353 Email: info@fireflex.com Web: www.fireflex.com FM-076D-0-23C 12 of 12