FireFlex DUAL Double Interlock, Self-contained system

Similar documents
FireFlex 1230 Self-contained system

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

TotalPac 3 Single interlock Firecyle III Preaction Self-contained system

TotalPac 3 Firecyle III Deluge Remote controlled system

TotalPac 3 Wet pipe system c/w retard chamber

TotalPac X Single interlock SUREFIRE system

TotalPac 3 Deluge, Electric release Self-contained system

TotalPac X Firecycle III Preaction Double interlock system

TotalPac 3 Single interlock Preaction, Electric release Self-contained system

TotalPac 3 Non interlock Preaction, Electric release Self-Contained system

TOTALPAC2 Integrated Fire Protection System

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

Specification/ Data Sheet

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

Integrated Fire Protection System. Owner's Operation and Maintenance Manual

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. 319a. January 27, 2012

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Worldwide Contacts.

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Instructions for Installation, Operation, Care and Maintenance

30.45 Electric Release PDRP-2001

TECHNICAL DATA OBSOLETE

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

FIRE SUPPRESSION SYSTEM

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Release Control Fire Alarm Systems

Commercial and Light Industrial Fire Alarm Control Panel

Operation & Maintenance Manual

Deluge & Preac tion Systems

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Conventional Releasing Control Panel

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Deluge System. Pneumatic Release. Deluge System. Pneumatic Release

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

LifeAlarm Fire Alarm Control Panels

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

TECHNICAL DATA OBSOLETE

Model DDX Deluge Valve

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

1935, Lionel-Bertrand Blvd. Boisbriand, Quebec, Canada J7H 1N8 Tel.: (450) Fax: (450) Toll Free: (866)

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

FireNET Plus Wiring Instructions

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

SECTION SPRINKLER SYSTEMS

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi CONTROL PANEL

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

AL800ULADA. NAC Power Extender. Installation Guide

FM-200 In-Cabinet Series

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

OPEN SPRINKLER SYSTEM

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Electric Release Panel Wiring Tips

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

AL600ULADA. NAC Power Extender. Installation Guide

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

Installation, Operating and Maintenance Manual

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

MR-2602 Two Zone Fire Alarm Control Panel

ECC-50/100C. Emergency Command Center

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi 50 CONTROL PANEL

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

TECHNICAL DATA. model c-2

Booster Power Supply Manual

Installation Guide for models:

Installation Guide for models:

Transcription:

FireFlex DUAL description The FireFlex DUAL integrated system consists of an integrated Double interlock preaction automatic sprinkler system combined with a clean agent fire extinguishing system, factory-assembled in a Double cabinet. All the components necessary for both extinguishing systems are integrated. The FireFlex DUAL is fully tested at factory. The FireFlex DUAL System uses Engineered SEVO 1230 FORCE500 Clean Agent Fire Suppression System for Class A, B and C fires. This clean extinguishing agent is based on sustainable technology and meets the most stringent actual and future environmental standards Novec 1230 extinguishing agent description Designed as per NFPA 2001, the extinguishing agent used in FireFlex DUAL system is Dodecafluoro-2-methylpentan- 3-one known as Novec 1230 Fire Protection Fluid (also known as FK-5-1-12, 3M TM NOVEC TM 1230 Fire Protection Fluid, C6-F-ketone) produced by 3M. Volumetric concentration varies from 4-6 % (not to exceed 10%) Novec 1230 Fire Protection Fluid is a colorless fluid. It is stored as a pressurized liquid and injected into a room, area, or compartment that has the structural integrity to retain the agent that has been discharged. Novec 1230 is dispensed as an odorless, electrically nonconductive vapor. It leaves no residue. Features FireFlex DUAL system utilizes Novec 1230 extinguishing agent which is highly efficient for total flooding applications and a Preaction automatic sprinkler system. FireFlex DUAL system is FM Approved under the heading: "FIXED EXTINGUISHING SYSTEMS, CLEAN AGENT FIRE EXTINGUISHING SYSTEMS". FIREFLEX DUAL System is UL Listed under "Clean Agent Extinguishing System Unit Category # GAQF- EX6174 and Category # GAQFC-EX6174 (ULC). Seismic type construction. ISO-9001 manufacturing and quality control procedures. Meet NFPA2001, Sec. 4.3.4.1 Novec 1230 extinguishing agent has zero ozone depletion potential, an atmospheric lifetime of 0.014 year and a global warming potential of 1. No Observed Adverse Effect Level (NOAEL) of 10%. USA TSCA: product complies with chemical notification requirements. Canada CDSL: product complies with chemical notification requirements Uses the Viking F1 Deluge Valves All trim piping is galvanized steel, Listed and Approved for 250 psi (1724 kpa) service maximum. Quick connections to water supply and drain on left side, and sprinkler riser on top of unit, available with grooved end or flanged fittings No open drain cups inside unit Separate unlocked access hatch to emergency manual release 1 of 14 FM-076D-0-16E

System configurations 2 Double Interlock Preaction combined with single NOVEC cylinder, electric release 3 Double Interlock Preaction combined with single NOVEC cylinder, electric release Cabinet width Size of cylinder (lbs) 40 76 164 322 601 850 36" 1 1 n/a n/a n/a n/a 46" n/a n/a 1 1 1 n/a 54" n/a n/a n/a n/a n/a 1-2 Sequence of operation Automatic release 1. Actuation of a detector from one detection zone: a) ZONE 1 (or ZONE 2 ) message appears on the display. b) FIRE ALARM lamp flashes until acknowledged. c) "ALARM" audible devices activate. d) ALARM contacts activate. e) Preaction solenoid valve (F1) activates. Note: Preaction piping network will not yet be filled with water. 2. Actuation of a detector from the other detection zone for crossed zones configuration): a) ZONE 2 (or "ZONE 1 ) message appears on the display. 3. Discharge sequence occurs: a) PRE-DISCHARGE and "DISCHARGE" lamps illuminate steady. b) PRE-DISCHARGE NOVEC 1230 contacts activate. c) Pre-discharge delay starts (not exceeding 60 sec). d) "SECOND STAGE ALARM" audible devices activate. Note: The abort station will prevent the NOVEC 1230 discharge as long as being maintained if activated during the pre-discharge delay. 4. After pre-discharge delay is completed: a) PRE-DISCHARGE lamp turns off. b) NOVEC 1230 electric actuator (C) activates. c) DISCHARGE NOVEC 1230 contact activates. If NOVEC 1230 discharge switch option is selected: d) DISCHARGE NOVEC message appears on the display. 5. After a preaction sprinkler head fuses: a) Deluge valve (A1) opens; water will flow into sprinkler piping network and out of sprinklers and any openings on the system. b) WATERFLOW PREACTION message appears on the display. c) WATERFLOW PREACTION contact activates. Manual release 1. Actuation of a manual release pull station within the system: a) MANUAL RELEASE message appears on the display. b) FIRE ALARM light flashes until acknowledged. c) "ALARM" audible devices activate. d) ALARM contacts activate. e) PRE-DISCHARGE and "DISCHARGE" lamps illuminate steady. f) Preaction solenoid valve (F1) activates. Note: Preaction piping network will not yet be filled with water. g) PRE-DISCHARGE NOVEC 1230 contacts activate. h) Pre-discharge delay starts (not exceeding 30 sec). i) "SECOND STAGE ALARM" audible devices activate. 2. After pre-discharge delay is completed: a) PRE-DISCHARGE lamp turns off. b) NOVEC 1230 electric actuator (C) activates. c) DISCHARGE NOVEC 1230 contact activates. If NOVEC 1230 discharge switch option is selected: d) DISCHARGE NOVEC message appears on the display. 3. After a preaction sprinkler head fuses: a) Deluge valve (A1) opens; water will flow into sprinkler piping network and out of sprinklers and any openings on the system. b) WATERFLOW PREACTION message appears on the display. c) WATERFLOW PREACTION contact activates. Note: At any time, if the optional mechanical activator (J) is activated, the NOVEC 1230 will be released. At any time, if the emergency release valve (B10) is activated, the preaction piping network will be filled with water. FM-076D-0-16E 2 of 14

Standard equipment Cabinet The FireFlex DUAL unit cabinet is made of sturdy 14 gauge steel. All surfaces are rust proof coated, inside and outside, with fire red, oven baked polyester powder on phosphate base. Cabinet is provided with one or two doors, all provided with a neoprene gasket to absorb vibrations. Electrical junction boxes are integrated inside the cabinet for connection of AC power, detection system, auxiliary contacts and signaling devices. Knockouts can be drilled by the installing contractor on-site. Cabinet doors are provided with hinges that can easily be disassembled on site to remove the door assemblies for servicing. Control panel (Self-contained system only) 120 VAC / 60 Hz, 165VA. 220 VAC / 50 Hz, 185VA. 12VDC / 18Ah batteries. (factory installed) Double Zone detection (Activated by Zone 1 or Zone 2) Crossed-Zone detection (Activated by Zone 1 and Zone 2) The release control panel integrated into the FireFlex DUAL cabinet is Notifier's Model NFS-320. This panel includes two Class A or B, programmable detection zones; four Class B supervisory zones and four Class A or B, programmable output circuits. Programming of the control panel made by Fireflex System Inc and password protected. The panel is compatible with many types of fire alarm & supervisory devices such as linear heat detectors, spot-type heat and smoke detectors, water flow and release indicators, low and high air pressure switches, manual pull stations. The control panel also includes an alphanumeric display with 2 lines of 40 characters describing all the system conditions, as well as a set of red and yellow LED lamps individually indicating the alarm and trouble conditions of the system Easy to operate control buttons are also provided to activate and operate the system's various functions. Standard SEVO SYSTEMS equipment Agent storage cylinder The agent storage cylinder by SEVO Systems is a steel pressure vessel manufactured, tested and stamped in accordance with DOT 4BW500 or DOT 4BA500, TC (Transport Canada). The agent storage cylinder is designed to hold the clean agent at a normal operating pressure of 500 psi (34.5 bar) at 70 F (21.1 C). The agent storage cylinders are suitable use at temperatures of 0 F (-17.8 C) to130 F (54.4 C). A rupture disc is connected to the cylinder body to serve as a pressure relief device to protect the cylinder against excessive internal pressure. The disc rupture point is in the range of 864 psi (59.5 bar) to 950 psi (65.5 bar) at 70 F (21.1 C). Cylinder filling range FireFlex 1230 Cylinders Size Fill Capacity (lbs) 40 16-40 76 31-76 164 66 164 322 129 322 601 241-601 850 366-854 3 of 14 FM-076D-0-16E

Standard SEVO SYSTEMS equipment (cont d) Discharge valve The discharge valve is a Brass construction backpressure type valve. The piston in the valve bore is equipped with a copolymer seal that keeps the Novec 1230 under pressure within the cylinder. A small hole in the axis of the piston allows the cylinder pressure to equalize on both sides of the piston. Since the area at the top of the piston is greater than the area at the bottom of the piston, the net force seals the piston against the valve discharge outlet. When the cylinder pressure on the top of the piston is released by means of automatic or manual actuation, the cylinder pressure acting against the piston causes it to slide to its fully open position allowing agent discharge. The 40 lb and 76 lb cylinders are equipped with a 1 valve. The 164 lb cylinders are equipped with a 1 ¼ valve. The 322 lb. and 601 lb. cylinders are equipped with 2 ½ valves and the 850 lb cylinders are equipped with a 3 valve. Nozzles The Sevo nozzles are designed to provide rapid and thorough vaporization and distribution of agent with the air in the protected space. Standard nozzles are made of aluminum. Engineered system nozzles are available in five pipe sizes, ½, 1, 1-½, 2 and 2-½, 180º and 360º discharge pattern. Each nozzle has a standard female pipe thread for attachment to discharge piping. Nozzle shall be spaced in accordance with the instructions in the Engineered system design manual. Each nozzle shall be marked with the Sevo Systems part number. 1/2 @ 180º 1/2 @ 360º 1 @ 180º 1 @ 360º 1-1/2 @ 180º 1-1/2 @ 360º 2 @ 180º 2 @ 360º 2-1/2 @ 180º 2-1/2 @ 360º Electric actuator The SEVO electrical actuator is mounted on the top plug of the cylinder valve. The 24 VDC electric actuator is required to discharge the system electrically from a releasing control panel. Meets NFPA 2001, Sec. 4.3.4.1 with active installation supervision switch. Power Requirements 24 Volts d.c. Current 0.5A at 24 Volt d.c. The maximum nozzle height per layer of coverage is 16-4. Both 180º and 360º nozzles were tested for a maximum area coverage using a 32 wide by 32 long enclosure. Pressure gauge integrated low pressure switch The pressure gauge integrated switch is a means for both visual and electronic monitoring of the pressure condition within the cylinder. Furthermore, the pressure gauge integrated switch eliminates the need for a separate pressure switch. - + 2 1 WARNING DO NOT INSTALL IF PLUNGER IS EXTENDED FM-076D-0-16E 4 of 14

Standard SEVO SYSTEMS equipment (cont d) Liquid Level Indicator The SEVO Liquid Level Indicator is a simple, manually operated device, which provides means to determine the fluid level in a vertically mounted cylinder. Use of this device allows for the content of fluid to be determined without removing cylinder from its bracketing and piping for weighing. Provided and available only on 322, 601 & 850 Cyl. Releasing circuit disable switch The releasing circuit disable switch is used to disable the clean agent electrical actuator. When the key is set to Disable, the SEVO electrical actuator will be disconnected from the control panel s releasing circuit, causing a trouble signal and preventing accidental discharge during maintenance or inspection. Meet NFPA 72, Sec. 23.11.5.2 1 in Optional SEVO SYSTEMS equipment Manual actuator (optional) The manual actuator features a push lever that vents pressure through the top of the valve causing the piston to rise and allow for Novec 1230 to discharge through the valve outlet. The manual actuator also has the option to mount on top of the stackable electric actuator allowing electrical or manual system activation. Discharge pressure switch (optional) The discharge pressure switch is used to provide a means of detecting system activation. Upon activation of the cylinder valve, the discharge pressure switch contacts transfer to indicate discharge and/or to perform auxiliary functions required during system operation. RED (+) WHITE (GROUND) BLACK (-) FM-076Z-0-2A As per NFPA 2001 (2008 Edition), 4.3.3.5.1. A discharge pressure switch shall be required where mechanical system actuation is possible. 5 of 14 FM-076D-0-16E

Standard Preaction equipment Preaction valve The Viking Model F-1 Deluge Valve is a quick-opening, differential diaphragm flood valve with one moving mechanism. The deluge valve is used to control water flow in preaction sprinkler systems. The valve is held closed by system water pressure trapped in the priming chamber, keeping the outlet chamber and system piping dry. In fire conditions, when the releasing system operates, pressure is released from the priming chamber. The deluge valve clapper opens to allow water to flow into the system 2 3 Solenoid valve The high pressure solenoid valve is a two-way type with one inlet and one outlet. It is a packless, internal pilot operated valve, suitable for use in releasing water pressure from the priming chamber of Viking Deluge Valves. The solenoid valve has floating diaphragm construction, which requires a minimum pressure drop across the valve to operate properly. IN OUT Low air supervisory switch The low pressure switch monitors the pressure within the sprinkler piping should a loss of the air below 12 Psi occur. The pressure switch contacts transfer indicating supervisory signal. Preaction riser check valve The Viking 2 spring loaded In-Line check valve is a general purpose rubber-faced check valve approved for use in fire-service systems. The Spring Loaded In-Line check valve is manufactured with a brass body, brass seat, and a rubber-faced clapper assembly. The Viking 3 Easy Riser Swing check valve is a general purpose rubber-faced check valve approved for use in fire service systems. The valve is for use in preaction system risers. 2 3 Alarm pressure switch POTTER PS40-1A The alarm pressure switch monitors the water flow within the sprinkler piping. Should the Deluge Valve clapper opens to allow water to flow into the sprinkler piping. The alarm pressure switch will activate, indicating a water flow signal POTTER PS10-1A FM-076D-0-16E 6 of 14

Preaction system - Air supply Direct air compressor (Style A ) Used only for the sprinkler piping network of the preaction system. Air supply Style "A" includes the air compressor mounted inside the FIREFLEX DUAL cabinet with its supervisory trim and options. Compressor is factory piped to the sprinkler piping system riser. It is available in three (3) sizes: 1/6HP 1/3HP 1/2HP All the above air compressors are oiless piston type without reservoir and have open, Double phase motor with internal thermal protection and supply voltage of Compressor selection Table: Compressor size CFM @ 40 psi 120VAC System capacity to pump 40 psi in 30 minutes 220VAC System capacity to pump 40 psi in 30 minutes 1/6 HP 1.33 CFM 125 gallons 163 gallons 1/3 HP 2.61 CFM 250 gallons 198 gallons 1/2 HP 4.06 CFM 365 gallons 301 gallons 120Vca, 60Hz This section replaced by Dehydrator option (when used) 220Vca, 50Hz. Pressure relief valve Compressor Amp rating Compressor size Amp rating @ Amp rating @ 120VAC, 60Hz 220VAC, 50/60Hz 1/6 HP 5 A 2.7 A 1/3 HP 7.4 A 3.7 A 1/2 HP 10 A 5 A E4 (plugged with SureFire trim) 3 TO PNEUMATIC ACTUATOR (plugged when not used) 2 TO DRAIN COLLECTOR 1 Copper tubing TO OPTIONAL ACCELERATOR (plugged when not used) TO SPRINKLER RISER CONTRACTOR'S HYDROSTATIC TEST PORT (system side) FM-061H-0-118C Air Pressure Maintenance Device (Style B ) Used only for the sprinkler piping network of preaction system, when an external air supply is provided by others (tank mounted compressor, plant air or dry nitrogen cylinders) and piped to the air inlet port of the unit. Air supply style "B" provides an Air Pressure Maintenance Device (APMD) trim, factory mounted in the FireFlex DUAL cabinet. This section replaced by Dehydrator option (when used) TO PNEUMATIC ACTUATOR (plugged when not used) 3 Contractor external Air or Nitrogen connection TO OPTIONAL ACCELERATOR (plugged when not used) 1 TO SPRINKLER RISER CONTRACTOR'S (system side) Note: The external air supply must be restricted to insure that it cannot replace air as fast as it escapes when a releasing device or sprinkler operates. 7 of 14 FM-076D-0-16E

Optional PREACTION equipment Shut-off valve & sight glass (optional) Semi-flanged inlet / outlet (optional) The Shut-off Valve & Sight Glass Option is intended to be used for applications where testing of the system operation without filling the sprinkler piping network is desirable and where it is critical that all functions of the preaction system be tested under actual discharge conditions. When required by the user, FireFlex DUAL units can be provided in a semi-flanged configuration. The semi flanged option provides flanged fittings only on the water inlet pipe (left side) and on the system riser outlet. The drain manifold is provided with a threaded connection (left side). The rest of the fittings are the same as usual with the main components being provided in the standard flanged / grooved configuration. Main Drain Valve (D3) Sight Glass Assembly (D5) Point flash light here Supervised Shut-off Valve (D4) Supervised Water Supply Control Valve (D1) Flanged fitting outside cabinet (when provided) Threaded end Field Connection to Open Drain (specify side) FM-061H-0-75C Flanged fitting outside cabinet (when provided) Field connection to Water Supply (specify side) FM-061H-0-77C Dehydrator (optional) The Viking Dehydrator is a manually regenerated desiccant-type air dryer. The desiccant acts as a moisture indicator by changing color, and is visible through the required bowl guard and transparent plastic bowl. From Air Supply E14 B13 From Air Supply To Air Option A Trim To Air Option B Trim Canister Body Canister Body E12 Dessiccant Sight Glass Dessiccant Sight Glass TO DRAIN COLLECTOR 2 FM-061H-0-124A FM-076D-0-16E 8 of 14

Details & field wiring diagrams Cabinet with main components, shown without door(s) Clean agent outlet Air compressor Isolation switch Junction box TBA, TBB & TBC Releasing circuit disable switch Air compressor (behind control panel) Control panel Preaction outlet Preaction assembly Agent storage cylinder Drain outlet Water inlet FM-076Z-0-5D-5 9 of 14 FM-076D-0-16E

Wiring diagram AC POWER SOURCE INPUTS CONTROL PANEL 1.4A@120VAC 0.7A@220VAC CLASS B DETECTION COMPRESSOR WITH A/B SELECTED 120/220VAC 1/2 HP MAX UNUSED 3.9K CIRCUIT 1/4W XP6-MA CLASS A DETECTION WITH A/B UNSELECTED UNUSED CIRCUIT XP6-MA 120VAC, 60 Hz 220VAC, 50/60 Hz LINE (L1) NEUTRAL GROUND GROUND NEUTRAL LINE (L2) DETECTION ZONE 2 3.9K 1/4W DETECTION ZONE 2 TBB 1 2 3 4 5 6 DETECTION ZONE 1 3.9K 1/4W DETECTION ZONE 1 Cable size: 14AWG min with 600V isolation ABORT 47K NOVEC 1230 1/4W XP10-MA! Two (2) circuits are required. Control panel shall have a dedicated circuit breaker. MANUAL 47K RELEASE 1/4W XP6-RA TBA 1 2 3 4 5 6 7 C NO NC SILENCEABLE AUDIBLE DEVICES + - + - ALARM + - + - 2.2K 1/2W 2.2K 1/2W NAC1 ALARM NAC2 SECOND STAGE ALARM ALARM ALARM PRE-DISCHARGE NOVEC 1230 PRE-DISCHARGE NOVEC 1230 DISCHARGE NOVEC 1230 WATER FLOW PREACTION XP6-MA 8 9 C NO TROUBLE LEGEND 10 NC SMOKE DETECTOR BELL OR HORN 11 12 C NO SUPERVISORY HEAT DETECTOR SOLENOID VALVE 13 14 15 16 17 NC + - DATA LOOP + 24VDC RESETTABLE PULL STATION END OF LINE RESISTOR DRY CONTACT FM-061H-0-67C XP6-RA XP10-MA MODULE LOCATION 18 19 C NO MAIN VALVE 20 NC LOS ANGELES OPTION 21 22 C NO SHUT-OFF VALVE CHICAGO OPTION 23 NC Power limited (supervised) initiating device circuits Detection Zone 1 and 2 (Class A or B) End of line resistor: 3.9KΩ, ¼W Loop resistance: 25Ω max. Leave EOL device (provided) on all unused circuits. Refer to the NFS-320 control panel manual for smoke detector compatibility. Power limited (supervised) initiating device circuits Abort and Manual release circuits (Class B) End of line: 47KΩ, ¼W Max. Loop resistance: 50Ω Leave EOL (provided) on all unused circuits. For dry contact supervisory devices only (Class B only) Auxiliary relay contacts Rated 2A, 30VDC resistive Rated 1A, 30VDC (0.6pF) inductive Rated 0.5A, 125VCA (0.35pF) pilot duty Power limited (supervised) notification appliance circuits NAC Circuit 1 and 2 (Class B) End of line resistor: 2.2KΩ, ½W Nominal operating voltage: 24VDC regulated Maximum wiring voltage drop into alarm: 1.2V Maximum usable current per circuit: 1.5A Maximum total current (including 24VDC): 3A Polarity is reversed in supervisory condition. Leave EOL device (provided) on all unused circuits. Refer to the NFS-320 control panel manual for device compatibility. Auxiliary Power 24Vdc Regulated Source Nominal voltage: 24VDC, 176mVrms ripple Maximum available current: 1.25A for resettable 4 wires smoke detectors FM-076D-0-16E 10 of 14

Cabinet The FIREFLEX DUAL cabinet is made of sturdy 14 gauge steel. Refer to table 8.1 and figure 2 for dimensions. All surfaces are rust proof coated, inside and outside, with fire red, oven baked polyester powder on phosphate base. Cabinet is provided with two doors, all provided with a neoprene gasket to avoid vibrations, giving the access to the pressure gauges reading and the manual emergency release. The cabinet assembly is pre-assembled, pre-wired, and factory tested under ISO-9001 conditions. Refer to tables 8.2 & 8.3 for installation and clearances details. Electrical junction boxes are integrated inside the cabinet for connection of detection system, auxiliary contacts and signaling devices. Knockouts can be drilled by the installing contractor on-site but must adhere to the restrictions indicated on figure 1. Figure 1 - Drilling details Top of Cabinet High voltage 2½" Low voltage 2½" Typ. 8½" 3¾" 3" FM-061H-0-68B-12 11 of 14 FM-076D-0-16E

Figure 2 - Cabinet dimensions A B M R Ø U S T 12'' MIN 12'' MIN N 22'' MIN C J FM-061H-1-49B-7 F J 5'' Ø3/4" Q 2"Ø O L H Ø E P K D FM-061H-1-49B-1 G FM-061H-1-49B-6 Table 8.1 - Cabinet dimensions Size A B C D E F G 36" 35¾" 25" 77⅛" 39¾" 15" 37¾" 12¾" 46" 46" 25" 77⅛" 50" 15" 48" 23" 54" 54" 31" 81" 58" 21" 56" 26" Table 8.2 - Preaction piping installation Notes: H J K L M N1 N2 O P Q 2" 11½" 8" 5" 9¾" 45" 48⅞" 4" 11½" 3½" 3" 11½" 9" 4" 9½" 45" 48⅞" 4" 12¾" 3" 1. N1 refers to 36" or 46" cabinet. N2 refers to 54" cabinet. 2. Dimensions may slightly differ from real unit. Table 8.3 - NOVEC 1230 piping installation Lbs R S T U 40 1" 2¾" 6" 3¼" 76 1¼" 2¾" 6" 3¼" 164 1½" 2¾" 6" 1¾" 322 2" 6¾" 6" 4¾" 601 2½" 6½" 6" 3¾" 850 3" 9" 7" 5" FM-076D-0-16E 12 of 14

13 of 14 FM-076D-0-16E

1935, Lionel-Bertrand Blvd. Boisbriand QC Canada J7H 1N8 Tel.: 450-437-3473 Fax: 450-437-1930 Toll Free: 866-347-3353 Email: info@fireflex.com Web: www.fireflex.com