Sieger Apex. Flexibility that meets your requirements

Similar documents
Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger fixed gas detection. Fixed protection from hazardous gas

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

SIL 2. Ultima X Series Gas Monitors CERTIFIED

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

GAS DETECTOR ST400EC PART.NO

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Toxic Gas Detection. Model F12. Toxic Gas Detection

3M Oldham OLCT 100. Description. Fixed Gas Detector

Zareba System Overview

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Model D12. Digital Gas Transmitter

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

MDA Scientific Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Fixed Gas & Flame Detection International Product Range Overview

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Zareba Sensepoint Pro

Searchpoint Optima Plus

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Fixed-Point Industrial Fire and Gas Detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

ALTAIR 5X Multigas Detector

Monitores Personales. Personal Monitor

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Dräger Polytron 8000 Stationary gas detector (EC)

Fixed-Point Industrial Gas Detection

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

IGD.CO.UK

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Fixed-Point Industrial Gas Detection

Equipment. Model R002. Description. SF6 leak detector

ALTAIR 5X Multigas Detector Product Specification

Frequently Asked Questions

Micro III (Models G203, G203S, and G213) Operation Manual

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Polytron 5700 IR Detection of flammable gases and vapours

The Art of Gas Detection

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

SP-220. Features. Combustible handheld gas leakage detector

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Gas Detection For Life

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Dräger Polytron 7000 Fixed gas detector

G-TECTA TM. Portable Gas Detection Instruments

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Warranty Registration

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Toxic Smarter Transmitter Instruction Manual

SYSTEMS LTD. Model «FDG3» LEADERS IN PROCESS ANALYSIS AND CONTROL

incontrol Systems Inc. Flame and Gas Detection

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

UniSens 2-Wire Gas Transmitter

EXAMPLES OF HOW TO ORDER

XNX Universal Transmitter

Zareba Metro Gas Detector

APPLICATION DATA SHEET

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

ESD3000 ESD200 Combustible / Toxic Gas Detector

Transmitters/Sensors. OLCT Series

Industrial Grade Gas Detection Detecting The Difference

MICRO III (G202 / G202s / G212) Single Gas Detector

EXAMPLES OF HOW TO ORDER

FX-SMT Series INSTRUCTION MANUAL P/N THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038

UniSens. 2-Wire Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

ESD500. ESD500 Combustible / Toxic Gas Detector

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Zareba Unipoint controller

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

ULTIMA X5000. MSAX5000.com

Model D12-IR. Digital Gas Transmitter...

Transcription:

Sieger Apex Flexibility that meets your requirements

Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong integral 316 STST mounting bracket Large easy access cable entries Easy access terminal blocks Wide range of accessories Easy to Use Intuitive menu operating system Clear on screen instructions guide user Simple for button operation Multiple language options Transmitter recognizes new sensor cartridges Easy to change gas types Large clear backlit graphical LCD display Easy to Maintain Simple plug in under power sensor cartridge Smart cartridges are supplied pre calibrated Common transmitter for all gas types Simple filter replacement Apex takes all the best elements of gas detection design and combines them into one unit. Apex provides the highest performance, installation flexibility, a wide range of accessories and a choice of communication outputs. All this is provided in a package that is easy to install, operate and maintain. Typical applications include: Petrochemical Exploration drilling rigs, production platforms, FPSO s, oil and gas terminals, chemical plants, oil and gas tankers Heavy Industrial Steel manufacture, ship building Manufacturing Automotive, glass and ceramics, aerospace, printing and coating, cosmetics Pharmaceutical Research labs, solvent storage areas, process areas, demineralisation plants Transmitter The robust hazardous area approved Apex transmitter housing and mounting bracket is made from 316 Stainless Steel. It has a large backlit LCD display, simple 4 button operation, 3 fully configurable relay outputs and selectable sink, source or isolated 4-20mA signal. The transmitter is common to all types of sensor. Sensor The Apex Sensor can be mounted directly on the transmitter or remotely up to 100m away. There are two versions of sensor; one for both catalytic and electrochemical type sensor cartridges and one for the thick film (semi conductor) type cartridges. Smart cartridge The sensors can be fitted with a choice of over 40 toxic gas ranges and wide range of detectable flammable gases. Each cartridge is pre calibrated and simply plugs into the sensor. The Intrinsically Safe design allows cartridges to be changed with the unit under power. The transmitter recognizes a newly fitted sensor cartridge and automatically reads all the configuration information from it.

General specification General Specification Power supply Power consumption (typical) Outputs Relay outputs Analogue signal Digital output Material and weight 24Vdc nominal (18-32Vdc) Apex 3W toxic, 4.6W catalytic, 4.6W thick film A1, A2 and Fault 2A at 30Vdc* selectable normally open or normally closed and normally energised or normally de-energised 4-20mA sink, source or isolated output LonWorks (optional) only available on ATEX certified version 316 Stainless Steel 5.25kg (11.55lbs) Accuracy Baseline ±3%, at 50% FSD ±4% Repeatability Linearity Response time (typical) Catalytic Toxic Stability (typical) Temperature: Time: Operating temperature Operating humidity ±2% at 50% FSD <5% FSD T50 <5 seconds, T90 <10 seconds T50 <12 seconds, T90 <30 seconds <±5% FSD (zero), <±5% FSD (span) <±3% FSD / year (zero), <±4% FSD / year (span) -40 C to + 65 C (-40 to + 150 F). Operating temperature of electrochemical cell cartridges is cell dependent. LCD display operates over -20 C to +65 C 0-99% (non condensing) Environmental protection IP66/67 to BS EN60529:1992 (Equiv. NEMA 4X / NEMA 6) Approvals CE Approved to all applicable European directives. EMC EN50270: 1999 type 2 Performance standards Exam (DMT) EN50054/50057/50271. CSA C22.2 No.152 (with cartridge 2110B3754) Certification ATEX II 2G EEx d ia IIC, CSA Class 1, Division 1 groups B, C and D C22.2 No.152 UL Class 1, Division 1 groups B, C and D, and Class 1, Zone 1 AExd [ia] IIC ATEX and UL T4-40 to +80 C (-40 to +176 F), T5-40 to +55 C (-40 to +131 F) CSA T4-40 to +75 C (-40 to +167 F), T5-40 to +55 C (-40 to +131 F) * CSA / UL rating 1A at 28Vdc Available gases and ranges* Gas Formula Ranges Cell type Flammable Various 0-100%LEL or 0-10%LEL CAT/TF Ammonia NH 3 0-50ppm, 0-100ppm, 0-400ppm or 0-1000ppm ECC/TF Arsine AsH 3 0-0.2ppm ECC Boron trichloride BCI 3 0-6ppm ECC Bromine BR 2 Carbon monoxide CO 0-100ppm, 0-200ppm or 0-500ppm ECC Chlorine Cl 2 0-2ppm, 0-5ppm or 0-15ppm ECC Chlorine dioxide ClO 2 Diborane B 2 H 6 Dichlorosilane SiH 2 Cl 2 0-10ppm ECC Ethylene oxide C 2 H 4 O 0-4ppm or 0-50ppm ECC Fluorine F 2 0-4ppm ECC Germane GeH 4 0-0.8ppm ECC Hydrogen H 2 0-1000ppm ECC Hydrogen bromide HBr 0-12ppm ECC Hydrogen chloride HCl 0-20ppm ECC Hydrogen cyanide HCN 0-20ppm ECC Hydrogen fluoride HF 0-12ppm ECC Hydrogen sulfide H 2 S 0-15ppm, 0-20ppm, 0-50ppm or 0-100ppm ECC/TF Nitric oxide NO 0-100ppm ECC Nitrogen dioxide NO 2 0-12ppm ECC Oxygen O 2 0-21%V/V ECC Ozone O 3 0-4ppm ECC Phosphine PH 3 0-1.2ppm ECC Silane SiH 4 0-20ppm ECC Sulfur dioxide SO 2 0-8ppm, 0-15ppm, 0-50ppm ECC CAT- Electrocatalytic, ECC- Electrochemical Cell, TF- Thick Film Semi Conductor *For other gases and ranges not listed contact Honeywell Analytics. * Oxygen detection products must only be used to detect oxygen depletion in air.

As World leaders in gas detection solutions, Honeywell Analytics Sieger systems provide the most efficient, practical and cost-effective fixed-point equipment. Wherever protection is required from flammable or toxic gases, you can rely on our equipment to provide practical solutions and to help keep your business running safely and profitably. The Sieger range of fixed gas detection Searchpoint Apex Searchline Excel Optima Plus Signalpoint System 57 Typically used in the oil and gas distribution, petroleum extraction and chemical manufacturing industries, the Apex gas detector and transmitter functions across a wide range of detectable flammable and toxic gases. With its rugged 316 stainless steel enclosure, it is especially suited for extreme conditions, and provides a cost-effective gas detection solution for a wide range of applications. Searchline Excel Cross Duct TM is an open path infrared gas detector for the detection of Hydrocarbons within HVAC air intakes and ventilation ducting systems up to 5 meters in width. It is based on the proven Searchline Excel, which covers ranges up to 200m. ClearShield TM glass coating, infrared beam and heated optical surfaces all combine to reduce downtime and increase system availability. Designed for use in potentially explosive atmospheres in harsh environmental conditions, SearchPoint Optima Plus is ideal where speed of response, reduced maintenance and failsafe operation is essential. Common applications include offshore platforms, production storage and offloading vessels, and oil and gas terminals. Signalpoint is a self-contained gas sensor system for either combustible or toxic gases, designed to make installation simple and maintenance minimal. Constructed in strong plastic, it is particularly suited for indoor applications in light industrial environments. The System 57 controller provides display and alarm facilities for the full range of gas detectors. It comprises a rack unit with mounting options for channel control cards and interface cards. Searchflame 16 705 HT Sensor Searchflame 16 is a range of optical flame detectors for detection of Hydrocarbon and non-hydrocarbon flaming fires in designated hazardous areas. Operating on UV or UV/IR principles, they have a 120-degree field of view, providing the widest coverage available by any product. The 705 High Temperature Sensor is a hazardous area certified sensor for the detection of combustible gases. Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. 2005 Honeywell Analytics H_Apex DS_V1 12/05 2005 Honeywell Analytics

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.