CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Similar documents
CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

CWA4 Chilled & Hot Water Fan Coil

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

Commercial High-Efficiency Condensing Units

FCC Fan-Coil Units High-Performance, Vertical

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

SKYPAK II, 3 Ton Series, gives you a

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

SKYPAK II, 3 Ton Series, gives you a

Product Specifications. Vertical Floor Consoles By First Co.

catalog CDV Fan-Coil Units High-Performance, Vertical

Commercial High-Efficiency Condensing Units

Q-TEC QC-Series Chilled Water Air Conditioner

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

C13-Series Engineering Guide

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

SpaceKeeper Console (SKC)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

SKYPAK II Heating & Cooling Self Contained Packages

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

GUIDE SPECIFICATIONS AQUARIUS ii

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Q-Tec TM QC-Series Chilled Water Air Conditioner

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

PAJ3. Product Specifications

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Concealed Ducted Split Series R-407C MBH

TECHNICAL SPECIFICATIONS

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

VertiCool Aurora Engineering Guide

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

VERTICAL FAN COIL UNITS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

MERIT Series R-410A - Upflow / Horizontal

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Incremental Comfort Conditioners

Call us today! (800)

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

MERIT SERIES Up Flow / Horizontal

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Call us today! (800)

Call us today! (800)

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

General Description. Operation

Ruud Standard Efficiency Air Handler

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

MERIT Series R-410A - Upflow / Horizontal

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

technical guide Water-Cooled Self-Contained Units

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Rheem Standard Efficiency Air Handler

Submittal Data Performance Data Electrical Data

AIR HANDLERS AIR HANDLERS

SeasonMaker ThinLine Fan-coil Units

Portable Vertical Air-Conditioning and Heating Systems

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Ruud Standard Efficiency Air Handler

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

HIGH EFFICIENCY AIR HANDLER

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Indoor Air Handlers with Compressors MVS and MVW

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

4YCC3048A3096A /3/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

Transcription:

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3

HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua Model Number: CFFWA4P-08-1-U Part 1-General 1.01 System Description Multiaqua Chilled Water Fan Coils are manufactured with galvanized steel and high impact molded polymers. 1.02 Quality Assurance A. Certified in accordance with U.L. Standard 95, latest version (U.S.A.) B. Manufactured in a facility registered to ISO 9002, Manufacturing Quality Standard. C. Fully electrically tested at the factory. D. Damage resistant packaging. 1.03 Delivery, Storage and Handling A. Packaged and readied for shipment from the factory. B. Controls shall be capable of withstanding 150 F storage temperatures in the control compartment. C. Stored and handled per manufacturer s recommendations. Part 2-Product 2.01 Equipment A. General: 1. Unit shall be a factory assembled and tested chilled and hot water fan coil. 2. Shall be assembled with high quality. 3. Contained with the unit shall be all factory wiring, piping, associated controls. B. Unit Cabinet: 1. Composed of galvanized steel with baked polyester powder and high impact polymers. 2. Coil Compartment shall be internally insulated to ensure quiet operation. C. Fan Motors: 1. Shall be available in 208/230-1-50/60 VAC. 2. Fan motors shall be three speed, direct drive, and PSC type. 3. Totally enclosed. 4. Internal overload protected. 5. Unit shall contain a swing motor to modulate the discharge air. D. Blower Wheels: 1. Blower wheels are double entry and dynamically balanced. E. Water Coils: 1. Manufactured with water coils containing 3/8 copper tubing mechanically bonded to aluminum fins. 2. Coils shall be factory tested to 350 psig. 3. Maximum inlet water temperature 180 F 4. Primary coil and Secondary coil connections are opposite ends and are non reversible. 5. Pressure independent flow control required on both coils to not exceed max flow for each coil. i. Consult primary coil and secondary coil data for proper sizing F. Drain Pan: 1. All drain pans shall be coated on both the interior and exterior with baked polyester powder to resist corrosion. 2. The exterior of all drain pans shall be insulated with closed cell insulation to prevent condensation. 3. Pans shall contain drain tubing that is accessible from the back, bottom and side of the unit. G. Filters: 1. Unit shall contain washable filters. 2

Part 3-Controls and Safeties 3.01 Controls A. Fan coils shall be completely factory wired and tested. B. Unit shall include a terminal block that is capable of incorporating a field supplied 24 VAC thermostat. C. Controls shall be capable of incorporating a field supplied three speed fan speed switch and or thermostat. 3.02 Safeties A. Fan coil shall contain a field renewable fuse on the secondary voltage side of the transformer. B. Fan coil shall contain a non renewable thermal protector on the primary voltage side of the transformer. Part 4-Operating Characteristics: 4.01 Electrical Requirements A. Electrical shall include a terminal block for both high voltage and low voltage. B. Electrical power supply shall be rated to withstand 120 F operating ambient temperatures. Part 5- Definitions 5.01 Abbreviations A. = Cubic Feet per Minute B. DB = Dry Bulb Temperature C. EWT = Entering Water Temperature D. GPM = US Gallons Per Minute E. MBH = BTU X 1000 F. SC = Sensible Cooling G. TC = Total Cooling = Sensible + Latent H. WB = Wet Bulb Temperature I. WPD = Water Pressure Drop in feet of head J. db = Decibel Level K. m = Meter L. In = Inches M. FP I= Fins per Inch N. OD = Outside Diameter O. ID = Inside Diameter P. MCA = Minimum Circuit Amps Q. MOP = Maximum Over current Protection R. LBS = Pounds U.S. 5.02 Measurements A. All measurements with regard to length, width, and height shall be in inches. 3

208/230-1-50/60 CFFWA4P-08-1-U Product Specifications Physical Data Model Number Height (in) Length (in) Depth (in) Weight (lbs.) Primary Coil Rows FPI Water Inlet / Outlet OD (in) Secondary Coil Rows FPI Water Inlet/ Outlet OD (in) Drain Connection ID (in) CFFWA4P-08-1-U 11.3 64.9 28.3 94.8 3-14.625 1/14.625 1 tube *All dimensions rounded up to nearest tenth of an inch. All dimensions are as the unit is horizontal/ceiling mounted. Electrical Data Model Number High Speed Volts/ Phase/ Hertz Fan Motor (Qty) Watts Fan Motor Full Load Ampacity Fuse or HACR Circuit Breaker Per Circuit MCA MOP CFFWA4P-08-1-U 879 (1)87.85 1.06 3.0 4

CFFWA4P-08-1-U Chilled Water Performance Data CFFWA4P-08-01-U COOLING CAPACITIES (Primary Coil) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 23457 3.5 SC 18414 WPD 4.2 TC 25220 4.0 SC 19231 879* 42 WPD 5.4 TC 26763 4.5 SC 19870 WPD 6.7 TC 28023 5.0 SC 20501 WPD 8.2 *High Speed CFFWA4P-08-01-U COOLING CAPACITIES (Primary Coil) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 21149 3.5 SC 17505 WPD 4.2 TC 22654 4.0 SC 18166 879* 45 WPD 5.4 TC 23864 4.5 SC 18768 WPD 6.7 TC 25039 5.0 SC 19332 WPD 8.2 *High Speed Recommended minimum flow rate for the primary coil at > 2 fps is 3.5 gpm Recommended maximum flow rate for the primary coil at < 6 fps is 9.75 gpm 5

CFFWA4P-08-1-U Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered (Primary Coil) 50 879 3.5 4.0 24416 30618 36859 43132 49431 55750 62086 68435 74792 81155 4.0 5.1 25227 31630 38072 44544 51042 57560 64093 70639 77193 83753 4.5 6.4 25883 32448 39049 45681 52336 59011 65701 72403 79113 85830 5.0 7.8 26423 33120 39852 46613 53397 60199 67016 73844 80681 87523 (Primary Coil) 60 879 3.5 4.0 18384 24562 30781 37035 43316 49620 55942 62277 68623 74975 4.0 5.1 18986 25366 31786 38239 44719 51221 57740 64272 70815 77365 4.5 6.3 19472 26014 32595 39207 45845 52505 59181 65870 72569 79275 5.0 7.7 19874 26548 33259 40002 46769 53556 60359 67175 74000 80833 (Primary Coil) 70 879 3.5 3.9 12333 18490 24689 30925 37190 49786 56110 56110 62444 68788 4.0 5.1 12729 19087 25487 31922 38385 51378 57898 57898 64430 70791 4.5 6.3 13049 19569 26129 32724 39346 52653 59330 59330 66019 72716 5.0 7.7 13312 19965 26657 33381 40133 53696 60500 60500 67315 74139 (Primary Coil) 80 879 3.5 3.9 6265 12401 18582 24800 31049 37324 43619 49931 56255 62589 4.0 5.1 6457 12794 19175 25592 32040 38512 45005 51514 58036 64567 4.5 6.3 6611 13110 19652 26229 32835 39466 46116 52782 59460 66147 5.0 7.7 6739 13371 20044 26752 33487 40246 47024 53817 60622 67437 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: CFFWA4P-08-01-U HOT WATER CAPACITY (Primary Coil) ENTERING AIR TEMPERATURE GPM ENTERING WATER TEMPERATURE 140F 70F DB / 60F WB 3.5 43752 4.0 45171 4.5 46310 5.0 47244 6

CFFWA4P-08-1-U Chilled Water Performance Data CFFWA4P-08-01-U COOLING CAPACITIES (Secondary Coil) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 10234 3.5 SC 9393 WPD 2.6 TC 10919 4.0 SC 9730 879* 42 WPD 3.4 TC 11828 4.5 SC 10132 WPD 4.2 TC 12495 5.0 SC 10435 WPD 5.2 *High Speed CFFWA4P-08-01-U COOLING CAPACITIES (Secondary Coil) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 9247 3.5 SC 8659 WPD 2.6 TC 9715 4.0 SC 9293 879* 45 WPD 3.4 TC 10423 4.5 SC 9618 WPD 4.2 TC 10882 5.0 SC 9840 WPD 5.2 *High Speed Recommended minimum flow rate for the secondary coil at > 2 fps is 3.5 gpm Recommended maximum flow rate for the secondary coil at < 6 fps is 9.75 gpm 7

CFFWA4P-08-1-U Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered (Secondary Coil) 50 879 3.5 2.5 12599 15800 19041 22314 25615 28938 32280 35638 39008 42389 4.0 3.3 12971 16262 19590 22948 26333 29739 33163 36602 40052 43513 4.5 4.1 13280 16644 20043 23472 26925 30399 33889 37393 40909 44434 5.0 5.0 13541 16966 20425 23912 27422 30952 34497 38056 41625 45203 (Secondary Coil) 60 879 3.5 2.5 9548 12726 15944 19197 22478 25784 29111 32454 35811 39180 4.0 3.2 9824 13091 16397 19736 23103 26493 29901 33326 36764 40213 4.5 4.1 10053 13394 16772 20182 23618 27076 30552 34043 37546 41060 5.0 5.0 10247 13650 17088 20557 24050 27564 31096 34642 38200 41767 (Secondary Coil) 70 879 3.5 2.5 6488 9642 12838 16071 19335 22624 25936 29265 32610 35967 4.0 3.2 6669 9913 13198 16518 19867 23240 26635 30046 33472 36910 4.5 4.1 6819 10138 13495 16886 20305 23748 27210 30688 34180 37683 5.0 5.0 6946 10327 13746 17196 20674 24173 27691 31225 34772 38329 (Secondary Coil) 80 879 3.5 2.5 3417 6548 9724 12938 16184 19458 22754 26070 29403 32749 4.0 3.2 3505 6726 9991 13292 16624 19982 23363 26761 30175 33603 4.5 4.1 3578 6874 10212 13585 16987 20415 23863 27329 30809 34302 5.0 5.0 3639 6999 10398 13831 17292 20777 24282 27804 31340 34887 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: CFFWA4P-08-01-U HOT WATER CAPACITY (Secondary Coil) ENTERING AIR TEMPERATURE GPM ENTERING WATER TEMPERATURE 140F 70F DB / 60F WB 3.5 22691 4.0 23311 4.5 23822 5.0 24250 8

CFFWA4P-08-1-U Chilled Water Performance Data CFFWA4P-08-01-U COOLING CAPACITIES (Both Coils) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 32396 7.0 SC 23163 WPD 7.3 TC 34178 8.0 SC 23956 879* 42 WPD 9.4 TC 35969 9.0 SC 24713 WPD 11.9 TC 37259 10.0 SC 25286 WPD 14.6 *High Speed CFFWA4P-08-01-U COOLING CAPACITIES (Both Coils) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 28911 7.0 SC 21763 WPD 7.2 TC 30455 8.0 SC 22479 879* 45 WPD 9.4 TC 32032 9.0 SC 23113 WPD 11.8 TC 33177 10.0 SC 23615 WPD 14.6 *High Speed Pressure independent flow control required on both coils to not exceed max flow for each coil Consult primary coil and secondary coil data for proper sizing Recommended minimum flow rate for both coils piped in parallel at > 2fps is 6.75 gpm Recommended minimum flow rate for both coils piped in parallel at < 6fps is 19.5 gpm 9

CFFWA4P-08-1-U Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered (Both Coils) 50 879 7.0 7.0 30350 38085 45867 53688 61541 69420 77321 85238 93169 101110 8.0 9.1 30903 38764 46669 54610 62579 70573 78585 86613 94654 102705 9.0 11.5 31331 39290 47288 55319 63376 71455 79552 87662 95785 103916 10.0 14.2 31675 39710 47782 55884 64010 72157 80319 88495 96681 104875 (Both Coils) 60 879 7.0 7.0 22808 30512 38266 46061 53891 61749 69630 77530 85445 93373 8.0 9.1 23217 31049 38928 46845 54793 62766 70761 78774 86800 94838 9.0 11.5 23535 31466 39439 47448 55485 63546 71626 79722 87831 95951 10.0 14.1 23789 31799 39847 47929 56036 64166 72313 80475 88649 96832 (Both Coils) 70 879 7.0 7.0 15253 22927 30654 38424 46232 54070 61933 69817 77717 85632 8.0 9.1 15521 23325 31178 39072 47000 54955 62933 70930 78943 86968 9.0 11.5 15729 23634 31583 39571 47589 55633 63697 71780 79876 87984 10.0 14.1 15896 23881 31907 39968 48058 56172 64305 72454 80616 88789 (Both Coils) 80 879 7.0 7.0 7684 15329 23030 30777 38563 46381 54227 62094 69980 77881 8.0 9.1 7813 15590 23419 31290 39198 47134 55096 63078 71077 79090 9.0 11.5 7914 15793 23719 31686 39685 47712 55761 63829 71913 80010 10.0 14.1 7995 15955 23960 32001 40073 48171 56289 64425 72576 80738 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: CFFWA4P-08-01-U HOT WATER CAPACITY (Both Coils) ENTERING AIR TEMPERATURE GPM ENTERING WATER TEMPERATURE 140F 70F DB / 60F WB 7.0 54550 8.0 55463 9.0 56162 10.0 56719 10

CFFWA4P-08-01-U Data MODEL # Fan Speed CFFWA4P-08-01-U L 650 M 750 H 879 Wattage @ High Speed 146 11

CFFWA4P-08-01-U Dimensional Drawing 12