OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS

Similar documents
PLEASE DO NOT DISCARD THE ATTACHED DOCUMENT IS NECESSARY FOR THE INSTALLATION OF YOUR GREASE TRAP.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

There are a few factors critical in the operation of a grease interceptor, which are: Design, Sizing, Proper installation and maintenance.

ROCKFORD S EPARATORS. Quality Separation Systems for over 35 years.

CHAPTER 10 TRAPS AND INTERCEPTORS

Innovative, Compact Design

Product Overview. About Us. Grease Traps Generic Types. Extended Capacity Hydromechanical Grease Traps

I. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice

4. TECHNOLOGY AND DESIGN CRITERIA

Grease Control Device Maintenance Recordkeeping

W-150-IS Specifications

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

CHAPTER VI BUILDING PLUMBING

Specification Drainage Engineering Guide. Lint Interceptors. Grease, Hair, Solids, and.

Prohibitions on using

CHAPTER 8 APPURTENANCES

.005 ATMOSPHERIC DEAERATOR

W-750-IS Specifications

1 Exam Prep Plumber s Handbook Tabs and Highlights

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

DEAERATORS .005 ATMOSPHERIC DEAERATOR

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

Keeping. Fats, Oils, and. Grease. Out of the Sewer

APPENDIX L ALTERNATE PLUMBING SYSTEMS

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

Grease Interceptors and Oil Separators

RESOLUTION Adopted this day of, President of June Lake Public Utility District and its Board of Directors

Read Only Document Not For Distribution

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

HotLine Internal Sewer Pipe Heater Installation Manual

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

CHAPTER 9 VENTS SECTION

How To Size A Big Dipper Unit

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Sanitary Drainage Systems

MAXI-VENT Air Admittance Valve

INSTALLATION INSTRUCTIONS REVISED: JUNE 2014

SERVING CANADA INSTALLATION INSTRUCTIONS REVISED: AUGUST 2014

InterSeptor Centrifugal Separators Operating & Maintenance Manual

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

The Enviro-Clean Air Scrubber keeps the Atmosphere Clear and Creates Clean Air

MATERIALS Traps TRAPS. No. IPC IRC Description

Installation and Operating Service Manual

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Phoenix C4XE - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart For use in Hazardous Duty Locations.

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

STACKS AND STACK VENTS

APPENDIX J ILLUSTRATIONS

KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation

Niles Steel Tank Hot Water Generator Installation and Operation Manual

CHAPTER 10 TRAPS AND INTERCEPTORS

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

SECTION STEAM CONDENSATE PUMPS

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

A. This Section includes the following emergency plumbing fixtures:

Read Only Document Not For Distribution

INSTRUCTION MANUAL with Replacement Parts

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SMITH STAINLESS FLOOR DRAIN SERIES - CAST

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

Rainwater - Management for the environment and nature protection

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

WATER HAMMER ARRESTORS & MISC. SPECIALTIES

SludgeHammer. Owner s Manual. Model S-400/600. The latest advance in wastewater treatment. NSF/ANSI Standard #40. nature called. we answered.

1.1 This section applies to air handling units for HVAC Systems.

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

SECTION DOMESTIC WATER AND DRAINAGE PIPING SPECIALTIES

2016 Plumbing Supplemental Plan Review List

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Drain and Vent Systems 6 CE Hours

Home owner s manual Pressure sewerage system

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.

MUD TRAPS MUD TRAPS. Standard version (to install in consolidated sand) Reinforced version (to install in sand)

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

A. Install all temporary erosion control measures (in accordance with MNDOT General Conditions 2573) prior to site disturbance.

Building Utilities 1 Plumbing and Sanitary Systems

ACT Cartridge Dust Collector

Structural Guidelines. Food Service Establishments. Retail Food Stores

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

GASEOUS HYDROGEN SYSTEMS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Transcription:

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS 5400-5500 SERIES INTERCEPTORS 5401 75 4NH 5500 50 3IPS INSTALLATION Place the Wade interceptor downstream of the drain which will supply the oil laden liquid. If the interceptor is to be installed below grade, insure an extension is provided to make the centerline of inlet to finished grade dimension. Compacted fill and/or gravel is recommended for support of the combined weight of the interceptor and the weight of the water. Piping from the appliances can then be routed to the inlet side of the interceptor. Connect piping from the outlet side to the oil interceptor or recovery device. If a flow control device is provided with the grease interceptor, it should be installed between the interceptor and the drain. Complete the piping on the outlet side to the sanitary sewer. 1 Wade Drains 11910 CR492, Tyler, TX, 75706 Phone: 800 638 9537 Fax: 888 879 9233 www.wadedrains.com 3 29 17

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS 5400-5500 SERIES INTERCEPTORS PURPOSE Wade oil interceptors have been used in plumbing waste systems to help protect property and the environment against explosion, fire, and pollution for many decades. Wade oil interceptors are designed similar to the grease interceptors. Both are designed on the principle that oils are lighter than water and thus gravity causes the oil to rise to the surface of the water. Wade oil interceptors come equipped with a removable combination pressure equalizing/flow diffusing baffle and with an optional sediment bucket on the inlet to trap stones, grit and other substances. Their solid flow-diffusing baffle eliminates turbulence and allows for high efficiency of separation. All Wade 5400 and 5401 oil interceptors are supplied with an adjustable oil draw-off assembly and vent connection. The interceptors are constructed of 100% steel, coated with a gray acid resistant epoxy. HOW THE WADE OIL INTERCEPTOR OPERATES Waste water draining to the interceptor passes through the inlet at a controlled rate. As water enters the interceptor, the baffle arrangement reduces turbulence to allow efficient separation. The oil, as separation occurs, floats to the top and is accumulated. The waste water, relieved of contaminates, continues to flow through the trap and into the drainage system. Solids and sludge carried in the water are stopped by the baffle and collected in the solids retaining bucket between the inlet and the flow-retarding baffle. Maximum separation and interception is affected in proportion to the elimination of turbulence of wastewater within the interceptor. The unique Wade baffle/bucket design permits almost 90 percent of the interior of the interceptor to be used for the function of oil separation. FEATURES Wade 5400 and 5500 series interceptors are equipped with a tread plate cover secured with hex head machine screws. A soft elastomeric gasket is attached to the body of the interceptor to prevent odor from escaping. An air relief is provided to eliminate siphonage and each unit is sized to insure it will perform to its rated capacity. INSTALLATION Install the interceptor as close as practical to the source(s) being served. Avoid installations where long runs of pipe (exceeding 25 ) are necessary to reach the interceptor. This precaution will preclude the possibility of oil and sludge becoming congealed in the pipe before it reaches the interceptor. The unit may be placed on the floor, partially recessed in the floor, recessed with the top flush with the floor or encased below the floor in an appropriate housing to accommodate piping and structural considerations. Whatever the installation method, anticipate sufficient clearance to remove the cover and baffles for cleaning. Verify that no obstructions will be placed over the interceptor after installation. A minimum clearance equal the overall height of the interceptor (excluding any extension) is recommended. Waste with heavy accumulations of sand or solids must bypass the interceptor because the rapid accumulation of solid matter will significantly reduce the rated efficiency of the interceptor. In an application where solids will be present, a solids interceptor should be used. Placement of a interceptor in a high traffic area is an important concern. If the unit is to be installed flush with the floor, it is necessary to load rate the interceptor cover. The standard Wade interceptor is designed for pedestrian and light traffic only. If heavy loads are anticipated, the interceptor must be specified with an appropriate reinforced cover. An extension is frequently used to increase the rough-in dimension from the inlet/outlet centerline to the finished floor. The extension anchor flange is not adequate to support the entire interceptor. For installations at flush-with-floor level, the interceptor chamber must rest on solid ground or a concrete pad. For upper floor installations, (suspended above the lower floor ceiling), the interceptor must be independently supported on hangers suitable to carry the entire weight. A single interceptor serving multiple fixtures or wash down areas is recommended only where the sources are located close together. In these installations, each drain should be individually trapped and vented. 2 Wade Drains 11910 CR492, Tyler, TX, 75706 Phone: 800 638 9537 Fax: 888 879 9233 www.wadedrains.com 3 29 17

Recommended Installations Commercial Uses Industrial Uses Filling and Service Stations Machine Shops Maintenance Garages Refineries Airport Hangars Fabrication and Welding Plants Laundries and Cleaning Establishments Parking Facilities FLOW CONTROL The interceptor is designed to achieve a predetermined optimum flow rate, thus eliminating turbulence and to regulate surges in the drainage line. The Wade flow control must be installed properly in every installation. An oil interceptor correctly designed to separate oil and light density substances from wastewater, will not by itself govern or regulate the flow of water through it at all times to sufficiently assure the flotation separation of the entrained substances which are to be intercepted at maximum efficiency. The flow control device, designed with an integral orifice, gives a pre-determined optimum flow rate and thus assures the elimination of turbulence in the oil interceptor, which could otherwise occur from sudden surges through the drainage line. The orifice openings are related to the size and gallons per minute rating of the oil interceptor. It should also be noted that standard orifice sizing is for gravity flow conditions where no pressure build-up is considered. If an interceptor is operating at maximum flow levels, a head may develop, in which case overload conditions may still exist. VENTING Oil interceptors must have a vented waste, sized in accordance with code requirements for venting traps, to retain a water seal and to prevent siphoning. All Wade oil interceptors are furnished with IPS threaded vent and draw-off connections on both the right and left hand sides of the interceptor with plugs in one side. If necessary, the vent and draw-off connections can be changed from one side to the other at the time of installation, by switching the plugs. The vent connections are located above the adjustable gravity oil draw-off standpipe in the intercepting chamber. Thus, the volatile gases rising from the intercepted substances are carried from the interceptor to the atmosphere. 3 Wade Drains 11910 CR492, Tyler, TX, 75706 Phone: 800 638 9537 Fax: 888 879 9233 www.wadedrains.com 3 29 17

ADJUSTABLE DRAW-OFF Wade oil interceptors are furnished with a IPS adjustable oil draw-off assembly. This draw-off can be furnished on either the right or left hand side of the interceptor. The oil draw-off consists of an adjustable pipe combination on the inside of the intercepting chamber, and a pipe connection from the internal adjustable standpipe on the side of the oil interceptor body to connect to an oil drain line from the oil interceptor to an oil storage tank. The adjustable standpipe can be raised or lowered inside the interceptor chamber to the proper height for draining off the separated oils and similar light density substances that have separated and floated to the surface of the interceptor chamber. Thus, after the oils and other substances have been accumulated in the interceptor, they can be drained from the interceptor chamber by gravity flow through the internal standpipe. The standpipe is adjusted so that the opening is located at 1/8 above the top of the water flow level in the interceptor chamber. There is no need to manually skim or dip out the oil, since the oil will drain off by gravity flow through the adjustable draw-off standpipe after it has been properly adjusted and tightened. 4 Wade Drains 11910 CR492, Tyler, TX, 75706 Phone: 800 638 9537 Fax: 888 879 9233 www.wadedrains.com 3 29 17

5400 Oil Interceptor Regularly Furnished: Fabricated A.R.C. steel oil interceptor with removable baffles, & gasketed cover. Project Engineer Mechanical GPM Pipe *Dimensions vary from illustra on Capacity Dimensions (Inches) No. of Lids Gallons Cu.Ft A B D E H 10 2 10 1.3 21 15 1/2 9 1/2 13 3 1/2 1 15 2 14 1.9 34 15 1/2 11 1/2 15 3 1/2 1 20 3 17 2.2 24 15 1/2 14 17 1/2 3 1/2 1 25 3 56 7.5 28 22 26 32 6 1 35 3 76 10.2 34 24 26 32 6 1 50 3 82 11.0 34 24 28 34 6 1 Suffix Options Suffix Description -18 Heavy Duty Cover * -24 Anchor Flange* -26 Anchor Flange w/ Clamp Device * -FH Housing w/ Adjustable Cradle * -FHT Full Housing w/ Adjustable Housing * -T Cover Recessed for Tile (Specify Thickness) * -XT Fixed Extension (Specify Height) * Outlet Variations -NH No-Hub -IPS Female Threaded 5 Wade Drains 11910 CR492, Tyler, TX, 75706 Phone: 800 638 9537 Fax: 888 879 9233 www.wadedrains.com 3 29 17

5401 Large Capacity Oil Interceptor Regularly Furnished: Fabricated A.R.C. steel oil interceptor with removable baffles, & gasketed cover. Project Engineer Mechanical GPM Pipe Capacity Dimensions (Inches) No. of Gallons Cu.Ft A B D E H Lids 75 4 168 22.4 48 34 28 36 8 2 100 4 188 25.1 51 36 28 36 8 2 125 4 195 26.1 53 36 28 36 8 2 150 4 215 28.7 58 36 28 38 10 3 200 4 309 41.3 68 38 32 42 10 4 250 4 427 67.0 74 40 38 50 12 4 300 4 526 70.2 78 44 40 52 12 4 350 6 590 73.5 80 46 40 52 12 6 400 6 622 83.1 82 48 42 54 12 6 450 6 665 88.8 84 50 42 54 12 6 500 6 783 104.5 86 62 46 58 12 6 Suffix Options Suffix Description -18 Heavy Duty Cover * -24 Anchor Flange* -26 Anchor Flange w/ Clamp Device * -T Cover Recessed for Tile (Specify Thickness) * -XT Fixed Extension (Specify Height) * Outlet Variations -NH No-Hub -IPS Female Threaded *Dimensions vary from illustra on 6 Wade Drains 11910 CR492, Tyler, TX, 75706 Phone: 800 638 9537 Fax: 888 879 9233 www.wadedrains.com 3 29 17

5500 Oil Interceptor with Integral Storage Compartment Project Engineer Mechanical Interceptor Capacity Holding Tank Capacity Dimensions (Inches) Gallons Cu.Ft Gallons Cu.Ft A B D E H 10 10.6 1.4 8.9 1.2 24 26 9 13 4 1 15 15.0 2.0 12.3 1.6 26 26 1/2 11 15 4 1 20 18.0 2.4 14.3 1.9 26 26 1/2 13 1/2 17 1/2 4 1 25 63.1 8.4 65.0 8.7 29 46 25 1/2 30 4 1/2 2 35 100.2 13.4 61.0 8.2 37 44 1/2 26 31 5 4 50 163.0 21.9 117.0 15.5 43 65 1/2 26 32 6 4 GPM Regularly Furnished: Fabricated A.R.C. steel oil interceptor with integral storage compartment, removable baffles, & gasketed cover. No. of Lids / GPM 10 15 20 25 35 50 Inlet / Outlet 2IPS/2NH 3IPS/3NH Suffix Options Suffix Description -18 Heavy Duty Cover * -24 Anchor Flange* -26 Anchor Flange w/ Clamp Device * -AP High Level Sensor w/ Audible Alarm -T Cover Recessed for Tile (Specify Thickness) * -XT Fixed Extension (Specify Height) * Outlet Variations *Dimensions vary from illustra on -NH -IPS No-Hub Female Threaded 7 Wade Drains 11910 CR492, Tyler, TX, 75706 Phone: 800 638 9537 Fax: 888 879 9233 www.wadedrains.com 3 29 17

5501 Large Capacity Oil Interceptor with Integral Storage Compartment INTERCEPTORS Project Engineer Mechanical Pipe Interceptor Capacity Holding Tank Capacity Dimensions (Inches) No. of Gallons Cu.Ft Gallons Cu.Ft A B D E H Lids 75 4 202 27.0 122 16.3 49 65 26 1/2 36 9 1/2 4 100 4 303 40.5 238 31.8 58 90 26 1/2 36 9 1/2 4 125 4 344 46.0 269 36.0 62 90 28 40 12 9 150 4 357 47.7 233 31.1 66 76 30 44 14 9 200 4 453 60.5 347 46.4 73 90 30 1/2 48 17 1/2 9 250 4 589 78.7 348 46.7 73 90 35 1/2 51 15 1/2 9 300 4 815 108.9 345 46.2 95 86 36 1/2 52 15 1/2 9 350 6 1066 142.5 569 76.0 101 94 43 1/2 60 16 1/2 9 400 6 1109 148.3 562 75.2 108 91 43 60 17 9 450 6 1113 148.8 566 75.7 119 83 43 60 17 9 500 6 1240 165.8 559 74.8 119 83 46 66 20 9 Regularly Furnished: Fabricated A.R.C. steel oil interceptor with integral storage compartment, removable baffles, & gasketed cover. / GPM Inlet / Suffix Options Outlet Suffix Description 75-18 Heavy Duty Cover * 100-24 Anchor Flange* 125 4IPS/4NH -26 Anchor Flange w/ Clamp Device * 150 -AP High Level Sensor w/ Audible Alarm 200 250 300 -T -XT Cover Recessed for Tile (Specify Thickness) * Fixed Extension (Specify Height) * Outlet Variations 350 400 450 6IPS/6NH -NH -IPS No-Hub Female Threaded 500 *Dimensions vary from illustra on 8 Wade Drains 11910 CR492, Tyler, TX, 75706 Phone: 800 638 9537 Fax: 888 879 9233 www.wadedrains.com 3 29 17