Beam detector DBD-DL40 KBD-DL80 KBD-DL100

Similar documents
Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID)

Our technology, your peace-of-mind. Product list

Open-area Smoke Imaging Detection (OSID)

this is by far the best beam money can buy

OSID in Challenging Environments

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

FIRERAY 5000 range USER GUIDE

Open-area Smoke Imaging Detector. Engineering Specification

OSID Smoke Detector. Product Guide. July 2011 Document No.: Revision: A Build: 4 Part No. LF42339

Reflective Optical Beam Smoke Detector User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Address: 2857 Sherwood Heights Dr. Unit 2, Oakville, ON, Canada. L6J 7J9 Toll free: LOGIKA

Apollo Intelligent Auto Aligning Beam Detector. User Guide

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

Line Smoke Detector LRMX

OSID Smoke Detector. Product Guide OSI-10 OSI-45 OSI-90 OSE-SP OSE-SPW OSE-SP-01 OSE-HPW

MODEL 6200 ANALOGUE ADDRESSABLE OPTICAL BEAM SMOKE DETECTOR

FAAST. Fire Alarm Aspirating Sensing Technology

Synchronous Detector

2 General Application Photoelectric Sensors

VISION H. Instruction manual

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

FAAST. Fire Alarm Aspirating Sensing Technology

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Optical Beam Smoke Detector RK90R - RK90RS

TECHNICAL SPECIFICATIONS BUTTONS

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Infrared LED Light - 3 watts - stud mount v - 750nm, 850nm or 940nm

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

English. Series. Installation and Use Manual

Addressable and Conventional Fire Protection

DELUGE SYSTEMS FALSE OPERATIONS

CODESEC FIRE ALARM SYSTEMS. security technologies

SecuriBeam Optical Beam Fire Detectors

2 General Application Photoelectric Sensors

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

SIMRAD GD10L - IR GAS DETECTOR OPERATING MANUAL

2 General Application Photoelectric Sensors

Installation and Operation Manual

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

HART XL High Sensitivity Smoke Detection

TECHNICAL FILE LEVELS AND MULTI-FUNCTION DETECTORS

ACP10 & ACP50 Security Systems

Infrared Temperature Sensor

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

FEC400 Series. Installation Manual

General Purpose Photoelectric Sensor

Reflective Beam Smoke Detector

SPACE DETECTOR SP Presentation

Photoelectric Beam Detector

Basic Vehicle Fire Protection Manual

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

The complete conventional fire warning system

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Outdoor Racks. - Especially designed for, telecomunications, - Double thermally installed. Product Datasheet CHARACTERISTICS

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

Dräger Polytron Pulsar 2 Open Path Gas Detector

Instruction manual EN

UNIVERSAL COMPACT SENSORS

Laser Level Measurement Products. Introducing the New LLT100

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

IR FLAME DETECTOR RIV-601/F

Extreme High-Intensity Sensors Thru-Beam and Fiberoptic Penetrates Many Packaging Materials for Content Verification

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

JEDI. Powerful recessed linear LED projector. Views

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

Table of Contents. 1. Mounting Tips... 2

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

PRELIMINARY PRODUCT CODE TYPE LOCATION DRIVER OPTICS LENGTH WATTAGE COLOR TEMP CABLE 3 + MOUNTING. Wall Grazer. Flood 32ºx85º K E End

Twin Photobeam Detectors Manual

DT1101A / DT1102A / DO110xA Automatic fire detectors

BOS 23K. Photoelectric Sensors BOS 23K

Fireray 2000 Linear Smoke Detector

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Sensing for standard and special applications

Flame Detector. Model: ZT-30P. User Guide. Document Ref: GLT Zeta Alarms Limited Morfa Road, Swansea, SA1 2EN, United Kingdom

General Specifications. Small size Fast 500µs response time Cable or quick-disconnect options 11 28V DC Operating Voltage Red output LED indicator

Kiddie After Discharge Clean-Up

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

CATALOGUE LASER POINTERS

ALK-V PHOTOELECTRIC SMOKE SENSOR

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

Acacia Batten. Contents. Willow Range 3 YE AR. Single. Twin. Single

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

Infrared Electric Heaters - General Product Information

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

JEDI. Powerful recessed linear LED projector. Views

Eliminating False Alarms in Toxic Gas Detection. Jason Schexnayder Sales Manager - Americas

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Transcription:

DBD-DL40 Beam detector Beam detector for distances over 5 metres and up to 40 meters, expandable up to 80 or 100 meters with extension kits. Separated head detector and controller for easy access to programming. IP65 for use outdoors or indoor with extreme environmental conditions. 24Vdc power supply. CPR certificate EN54-12. Dimensions: detector 180x155x137mm, controller 185x120x62mm. KBD-DL80 Mid range distance kit for beam detector DBD-DL40. Use this for distances over 40 meters and up to 80 meters. KBD-DL100 Long range distance kit for beam detector DBD-DL40. Use this for distances over 80 meters and up to a maximum of 100 meters.

KIT-DL Anti fog kit for beam detector DBD-DL40. Specially developed to overcome the problems of condensation, this special kit contains a reflector and lens cover that have been treated with a special Nano technology finish that will not mist over. REF-DL Anti fog reflector. A single reflector with a nano technology finish, sold singularly. SOP-DL Adjustable wall fixing for beam detector DBD-DL40. A very high quality aluminium fully adjustable bracket that can be accommodate both the beam head and the reflector. STI-9861

Galvanized steel cage coated with white polyester for the protection for beam detector from accidental or malicious blows that could misalign and / or affect the correct operation of the device. The grille is made of 9 gauge steel with polyester coating resistant to the corrosion. Dimensions: 160 x 186 x 143 mm STI-9862 Galvanized steel cage coated with white polyester for the protection of the control keyboard for beam detector. OSI-10 Optical beam detectors Linear detector (receiver) of smoke 10 degrees of vision. Detection based on the use of light at two different wavelengths. Maximum range 150 meters with 1 standard emitter. Field of view (7 degrees horizontal and 4 degrees vertical). Maximum of 1 emitter. Power supply at 24Vdc / 27mA. Status LEDs (alarm, fault and power). 3 levels of sensitivity (low, medium and high). Dimensions: 198 x 130 x 96 mm. OSI-45 Linear detector (receiver) of smoke 45 degrees of vision. Detection based on the use of light at two different wavelengths. Maximum range 120 meters with high power emitter / 60 meters with standard emitter. Field of vision (38 degrees horizontally and 19 degrees vertically). Maximum of 7 emitters. Power supply at 24Vdc / 27mA. Status LEDs (alarm, fault and power). 3 levels of sensitivity (low, medium and high). Dimensions: 198 x 130 x 96 mm.

OSI-90 Linear detector (receiver) optical smoke 90 degrees of vision. Detection based on the use of light at two different wavelengths. Maximum range 68 meters with high power emitter / 34 meters with standard emitter. Field of vision (80 degrees horizontally and 48 degrees vertical). Maximum of 7 emitters. Power supply at 24Vdc / 27mA. Status LEDs (alarm, fault and power). 3 levels of sensitivity (low, medium and high). Dimensions: 198 x 130 x 96 mm. OSE-SP Linear detector (emitter). Detection based on the use of light at two different wavelengths. Maximum range according to receiver model. Battery powered. Status LEDs (alarm, fault and power). 3 levels of sensitivity (low, medium and high). Dimensions: 198 x 130 x 96 mm. OSE-SPW Linear detector (emitter). Detection based on the use of light at two different wavelengths. Maximum range according to receiver model. Power supply at 24Vdc / 31mA. Status LEDs (alarm, fault and power). 3 levels of sensitivity (low, medium and high). Dimensions: 198 x 130 x 96 mm.

OSE-HPW Linear high-power detector (emitter). Detection based on the use of light at two different wavelengths. Maximum range according to receiver model. Power supply at 24Vdc / 31mA. Status LEDs (alarm, fault and power). 3 levels of sensitivity (low, medium and high). Dimensions: 198 x 130 x 96 mm. OSID-INST Kit Installation for the OSI series equipment. Includes laser, cable, manual, lens cleaner and test equipment.

STI-9845 Galvanized steel cage coated with white polyester for the protection of linear OSI smoke detectors from accidental or malicious blows that could misalign and / or affect the proper functioning of the device. The grille is made of 9 gauge steel with a resistant polyester coating to corrosion Dimensions: 234 x 167 x 104 mm