Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Similar documents
TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Universal Dimmer E450UD Series. Installation Instructions

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

Push Button Electronic Timer. 31VETR Series. Installation Instructions

Dimmer / Fan Controller Installation Instructions

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Mains Power Filter 970MF10 970MF20. Installation Instructions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

WAFER Recessed Edgelite Exit LED EXITREC. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

F Type Shielded Masthead Amplifier 3105MH35U18V DIGITAL TERRESTRIAL TELEVISION READY. Installation Instructions

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

Three Speed Capacitive Fan Controller. 4060CSFM Series. Installation Instructions 75VA

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

Passive Infrared Motion Detector 5420/90P. Installation Instructions

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Airflow. Add a little Sunshine to your bathroom

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

Universal Clamp Meter

Motion sensors for every application

DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home.

Consumer Switchboards 4CS & 4FCS. Installation Instructions

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

754 Series. See Motion Sensors. in a new light. Sleek new styling and more features than ever before.

Installation Instructions

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

Ceiling Mounted Ducted Exhaust Fan Kit

SMART HOME LIGHTING CONTROL C LIPSAL

Get connected with Xantrex Grid-Tie Inverters

C-Bus Neo Range Installation Instructions. 5050NL Series

C-Bus Reflection Range Installation Instructions

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Intercom Systems Video Intercoms

C-Bus Four Channel Analogue Output Unit Installation Instructions

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

C-Bus Four Channel General Input Unit Installation Instructions

Flexibility from floor to ceiling

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

Airflow. The coolest way to save energy

Lighting and Energy Control

Lighting & Energy Efficiency

Lighting and Energy Efficiency

Abella Digital Fade Dimmer

SHUTTLE BELL-PRESS DIMMER DATA SHEET

Pushing Boundaries in dimming technology

KADO LUX 3-IN-1 HEAT LIGHT EXHAUST

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

OPERATING INSTRUCTIONS

1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W

C-Bus Application Note. Function Rooms and Ballrooms. Overview

Pedestal Fan. 12 months. 3 Speed, 40cm R2000B

60cm Built-In Ceramic Cooktop

6.5L SLOW COOKER INSTRUCTION MANUAL

Reflector T2 and GU10 6,000 hours

Clipsal Mining Solutions. Increasing workplace safety. Adding value to mining operations.

Energy cost saving made easy!

FANAWAY LED EVO1 RETRACTING BLADE CEILING FAN

MILLI CUBE HEATED TOWEL RAIL 825 X 600

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

Universal pushbutton dimmer etd U2 etd 2e

Mira Vision Wireless Controller

INTENSA MRM0115 MRM0220 MRM0620 INTERIOR & EXTERIOR LED LIGHT. Operating Instructions

Model pictured: RPA3CI6SS/WH

NOVALED. The Revolutionary downlight is re-powered

Selection Guide. Tastic Eco Tastic Easy Duct Tastic Easy Duct Smart Switch Tastic. 5 Year in home warranty.

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

Operation, Maintenance and Installation Manual

Compact Movement Activated Sensor Installation Instructions

Easy Duct Tastic. User Guide. Model: Triumph Easy Duct Smart Switch Model: Sensation Easy Duct Smart Switch

Product Bulletin for Decora Rocker Slide Controls

VERSA INDOOR OLED LIGHT. Operating Instructions

OPERATING INSTRUCTIONS

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...

Pure Glass. saturn.clipsal.com

Read installation manual prior to installation of this appliance! Read user manual before putting this unit in operation!

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

FUTURA SERIES CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE


LUCCI FUTURA MOOD LED CEILING FAN

WARRANTY BOOKLET. Hotflo (HFE) Series. Electric Storage Water Heaters. Register online at

TRAVELMATE. Instruction Manual

WARRANTY BOOKLET. EHPA Electric Heat Pump Water Heaters. Register online at

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

Electrical Safety Tips. Help us keep you safe.

Wall Fan. 3 Speed, 40cm MWF40

TT302 (200W) Wireless receiver Pull cord Dimmer

Transcription:

Trailing Edge Dimmer 32E450T Series Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Table of Contents 1.0 Product Range...3 2.0 Description...3 3.0 Features...3 4.0 Load Compatibility...4 5.0 Incompatible Loads...4 6.0 Important Warning...4 7.0 Installation Instructions...5 7.1 Wiring Details... 5 7.2 Soft Start Feature... 5 7.3 Minimum Brightness Settings... 5 7.4 Multi-Gang Derating... 5 7.5 Thermal Overload Protection Circuitry... 5 8.0 Wiring Diagrams...6 8.1 One Way Operation... 6 8.2 Two Way Operation... 6 9.0 Electrical Specifications...7 10.0 Warranty Statement...8 Copyright Notice The concepts, products and designs described in this document are the subject of international patents, and protected by international law. Copyright Clipsal Australia Pty Ltd. All rights reserved. Trademarks Clipsal is a registered trademark of Clipsal Australia Pty Ltd. C-Thru The Clear Choice, is a registered trademark of Clipsal Australia Pty Ltd. All other logos and trademarks are property of their respective owners. Disclaimer Clipsal Australia Pty Ltd reserves the right to change specifications or designs described in this manual without notice and without obligation. 2 of 8 Copyright Clipsal Australia Pty Ltd

1.0 Product Range 32E450TM 32E450T 2032E450T C2032E450T SC2032E450T SL2032E450T P2032E450TM P2032E450T 1920E450T Dimmer, Trailing Edge, 220-240V a.c., 50Hz, 450W (30 Series Mechanism) Dimmer, Trailing Edge, 220-240V a.c., 50Hz, 450W (Standard Range) Dimmer, Trailing Edge, 220-240V a.c., 50Hz, 450W (2000 Series) Dimmer, Trailing Edge, 220-240V a.c., 50Hz, 450W (Classic Series) Dimmer, Trailing Edge, 220-240V a.c., 50Hz, 450W (Slimline Series) Dimmer, Trailing Edge, 220-240V a.c., 50Hz, 450W (Eclipse Series) Dimmer, Trailing Edge, 220-240V a.c., 50Hz, 450W (Prestige Mechanism) Dimmer, Trailing Edge, 220-240V a.c., 50Hz, 450W (Prestige Series) Dimmer, Trailing Edge, 220-240V a.c., 50Hz, 450W (Heritage Series) *Please note that these products are also available in other configurations and in a wide range of colours. For further information, please contact your nearest Clipsal Sales Representative. 2.0 Description The Clipsal 32E450T Series Dimmer is a separately switched, compact, modular dimming mechanism rated at 450W (1.8A). The unit utilises state-of-the-art trailing edge dimming technology to provide full control of incandescent lighting and electronic transformer based low voltage lighting. The 32E450T Series Dimmer is suitable for use in any new installation, but is also retrofittable, and may be used to replace a standard switch in any existing installation. 3.0 Features Separately switched compact modular dimming mechanism 450W rating Wall or architrave mounting options Wide range of plate styles and colour variants available Suitable for 1-way or 2-way operation Suitable for incandescent (tungsten filament) lamps Suitable for low voltage downlights using electronic transformers Soft start operation Preset minimum brightness Over temperature compensation Immune to high frequency (ripple) signal injection on mains supply Fitted with suppressors to minimise radio frequency interference Complies with Australian and International EMC Standards. Please note that the 32E450UD Series Dimmer is immune to the effects of high frequency (ripple) signal injection on the mains voltage supply. These signals are commonly injected onto the mains by the supply authority for such applications as off-peak hot water switching and remote meter monitoring. This Patented Australian design innovation ensures true flicker-free dimming operation. Copyright Clipsal Australia Pty Ltd 3 of 8

4.0 Load Compatibility The Clipsal 32E450T Series Dimmer is a part of the C-Thru Dimmer range. Each dimmer mechanism is colour coded to indicate load compatibility. LOAD SYMBOL M COMPATIBLE LOADS IMPORTANT NOTES: Any number of low voltage lighting transformers can be used providing the total lamp wattage does not exceed the maximum load rating of the dimmer. Use only electronic transformers compatible with electronic switches / phase controlled dimmers as recommended by the manufacturer. It is recommended that when using electronic transformers, each be loaded to at least 75% of their maximum rated load. This reduces the possibility of lamp flicker when dimming, as is common with some transformers. Refer to the manufacturer s specifications for the transformer being used. 5.0 Incompatible Loads Under NO CIRCUMSTANCES should the 32E450T be used for inductive load types such as low voltage lighting with iron-core transformers or fan motors. Failure to comply with this instruction will void any warranty associated with the product. Exercise care when using dimmable linear fluorescent or compact fluorescent load types (max. load 300W). Use only lamps/ballasts that are compatible with Trailing Edge phase angle control (lagging). Refer to the lamp/ballast manufacturer s specifications for further recommendations. Dimmer warranty is void when controlling incompatible load types as determined by Clipsal Australia. 6.0 Important Warning C-THRU COLOUR 32E450L 32E450T 32E500F 32E450UD BLUE GREEN AMBER TRANSPARENT LEADING EDGE DIMMER TRAILING EDGE DIMMER FAN SPEED CONTROLLER UNIVERSAL DIMMER 450W 450W 500W 450W Incandescent Lighting Halogen/Dichroic 240V Lamps 8 Low Voltage Halogen/Dichroic Lighting with Iron-Core Transformers 8 8 Low Voltage Halogen/Dichroic Lighting with Electronic Transformers 8 8 Small Motor Loads Exhaust Fans Ceiling Fans 8 8 It is illegal for persons other than an appropriately licensed electrical contractor or other persons authorised by legislation to work on the fixed wiring of any electrical installation. Penalties for conviction are severe. 4 of 8 Copyright Clipsal Australia Pty Ltd

7.0 Installation Instructions 7.1 Wiring Details 1. Disconnect power to the relevant circuit at the main switchboard. 2. Remove existing switch from wall. 3. Connect the dimmer in accordance with the wiring diagrams shown over the page. 4. Refit switch plate to wall. 5. Reconnect power. 6. Turn switch on and check dimmer operation by turning control knob through full range. NOTE: The Trailing Edge Dimmer does not incorporate a kick-start feature as is standard for other C-Thru Fan Controller models. The control knob must be sufficiently advanced when turned on, in order to achieve reliable motor starting. 7.2 Soft Start Feature The Trailing Edge Dimmer incorporates a soft start feature providing a noticeably smooth lamp illumination at turn on. This feature also minimises lamp filament start up stress, which may increase lamp life. 7.3 Minimum Brightness Settings The minimum brightness level has been factory preset to suit most applications. 7.4 Multi-Gang Derating For applications where 32E450T Series Dimmers are multi-ganged, derate the maximum load rating of the unit according to the derating table shown at right. Number of Dimmers Maximum Load per Dimmer 1 450W 2 350W 3 250W 7.5 Thermal Overload Protection Circuitry The 32E450T Series Dimmers incorporates two levels of thermal overload protection. Thermal Overload Compensation Automatically reduces lamp brightness should the dimmer be inadvertently overloaded. Primary defence against overload or short circuit. Resets automatically once overload conditions are corrected. Thermal Cutout The unit contains a non-resettable thermal fuse device designed to blow in case of catastrophic circuit failure. This is a secondary protection measure intended to operate as a backup in case of persistent or prolonged overload conditions. If the thermal cut-out fuse blows, then the dimmer will be rendered permanently inoperable and must be replaced. Any significant overload should be avoided in order to prevent damage to the load, fixed wiring of the installation or other hardware connected to the affected circuit. Copyright Clipsal Australia Pty Ltd 5 of 8

8.0 Wiring Diagrams 8.1 One Way Operation A C 1 Loop 2 30M Switch Mech LOAD Dimmer Mechanism N 8.2 Two Way Operation A C 1 Loop 2 C 1 Loop 2 30M Switch Mech LOAD Dimmer Mechanism N NOTE: If the unit is wired for 2-way operation it can be switched ON or OFF from either location, but the lamp brightness can only be adjusted from one location. Two or more dimmers cannot be connected in parallel or series to control the same load from two different locations. Dimmer mechanism wiring is not polarity sensitive. 6 of 8 Copyright Clipsal Australia Pty Ltd

9.0 Electrical Specifications Parameter Nominal Operating Voltage Nominal Operating Frequency Maximum Load Minimum Load Dimming Technique Compatible Loads Value 220-240V a.c. 50 Hz 450W @ 240V a.c., 400W @ 220V a.c. Derate for multi-gang applications 10W Trailing Edge Phase Control Incandescent lighting Halogen 240V lamps Low voltage lighting with electronic transformers Incompatible Loads Fluorescent lighting Low voltage lighting with iron-core transformers M Exhaust fans (shaded pole induction motors) Ceiling fans (split-phase induction motors) Operating Temperature Range 0 to 45 C Operating Humidity Range Mounting Centres Shipping Weight Safety Compliance EMC Emission Compliance 10 to 90% R.H. 84mm Australian Pattern Plate 25g Dimmer Mechanism Only AS/NZS3100, IEC60669-2-1 AS/NZS CISPR15:2002 Specifications Typical @ 240V a.c., 25 C No User Serviceable Parts Inside WARNING: Operation at temperatures or voltages outside of specification (240V a.c. 25 C) may cause the thermal protection circuitry to operate. Decrease the size of the connected load to prevent re-occurrence. Copyright Clipsal Australia Pty Ltd 7 of 8

10.0 Warranty Statement 1. The benefits conferred herein are in addition to, and in no way shall be deemed to derogate; either expressly or by implication, any or all other rights and remedies in respect to the Clipsal Product, which the consumer has under the Commonwealth Trade Practices Act or any other similar State or Territory Laws. 2. The warrantor is Clipsal Australia Pty Ltd of 33-37 Port Wakefield Road, Gepps Cross, South Australia 5094. With registered offices in all Australian states. 3. This Clipsal product is guaranteed against faulty workmanship and materials for a period of two (2) years from the date of installation. 4. Clipsal Australia Pty Ltd reserves the right, at its discretion, to either repair free of parts and labour charges, replace or offer refund in respect to any article found to be faulty due to materials, parts or workmanship. 5. This warranty is expressly subject to the Clipsal product being installed, wired, tested, operated and used in accordance with the manufacturer s instructions. 6. All costs of a claim shall be met by Clipsal Australia Pty Ltd, however should the product that is the subject of the claim be found to be in good working order all such costs shall be met by the claimant. 7. When making a claim the consumer shall forward the Clipsal product to the nearest office of Clipsal Australia Pty Ltd with adequate particulars of the defect within 28 days of the fault occurring. The product should be returned securely packed, complete with details of the date and place of purchase, description of load, and circumstances of malfunction. Clipsal Australia Pty Ltd clipsal.com A member of Schneider Electric Contact us: clipsal.com/feedback National Customer Care Enquiries: Tel 1300 2025 25 Fax 1300 2025 56 Clipsal Australia Pty Ltd reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. F1778/05 CLIPCOM 21092 April 2010