Radiant Mixing Block

Similar documents
Variable Speed Outdoor Reset 00 Circulator (00-VR)

Instruction Sheet RMB - Radiant Mixing Block

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Instruction Sheet X Pump Block (XPB)

- Essay Control Functions and Benefits

RMB - Radiant Mixing Block

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

- Data Brochure Universal Reset Control 364

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

Instruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

- Data Brochure Universal Reset Module 422

- Data Brochure Mixing Control 361

- Data Brochure Mixing Control 360

- Data Brochure Universal Reset Module 423

- Data Brochure Addendum

- Data Brochure D 260. Boiler Control /09

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

- Data Brochure Addendum

- Data Brochure Boiler Control 264

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1

Instruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators

Instruction Sheet 00 Variable Speed Delta T (00-VDT)

B-40/B-41 Modulating Temperature Controller

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

- Data Brochure Boiler Control 264e

- Data Brochure Boiler Control 268

Hydronic Mechanical Panels

- Data Brochure Boiler Control 274

- Data Brochure Mixing Control 360e

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

Installation & Operation Manual

- Application Boiler Control 260

BB3000 Series. Application. Features. Injection Pump Control General Instructions

Outdoor Reset IQ Option Card, p/n

Outdoor Reset IQ Option Card, p/n

- Data Brochure Snow Detector & Melting Control 667

- Data Brochure Mixing Reset Module 421

HYDRONIC COMPONENTS & SYSTEMS

Best Practices for Condensing Boilers

qualified heating installer/service technician

- Data Brochure Steam Control 279

Aquatrol Outdoor Temperature Compensators AQ675A for Floating Control Valves AQ775A for Injection Pumps

ProRadiant Controls, Valves and Actuators

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal

BHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions!

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

prestige Control Application Supplement - Type 5 MCBA WARNING

Taco 00 Series Cartridge Circulators

Dual Mixing Application

Melt Demand. Idle Demand WWSD. Minimum Maximum Water Melting. Do not apply power. 27 Zn 2. Melt/Idle. Slab. Demand. Input Universal Sensor Included

Better Design, Better Control, Better Systems.

Domestic Hot Water Systems and Plumbing Products

ProRadiant Basic Heating Control Installation Manual 2013

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

Advanced Snow Melt Control Installation Manual

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

- Data Brochure D 261. Boiler Control 261

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

The electrical wattage needed by the circulator is:

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Circulators high efficiency ECM Circulators

c0094 form 2. Project Identification Year: 2001 Project nº: 910

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

prestige Control Application Supplement - Type 5 MCBA WARNING

propanel Series Installation Manual

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

Boiler Manager Technical Report

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

AQ250 Series Hydronic Control Panels

Installation & Operation Manual

Heatronic 4000 IO Heatronic /04 en-us. Features. 4 boiler control, DHW, BACnet and Modbus. Installation/Operating instructions (IO)

prestige Control Application Supplement WARNING

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Hydronic & HVAC Control Systems

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Melting Control Stk# Melt Demand Idle Demand WWSD Minimum Maximum Water Melting. Do not apply power. 15 Mix Com. Mix. Melt/Idle Demand.

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

- Data Brochure Snow Detector & Melting Control 665

Authority - City Engineer Effective August 2, 2011 Amended November 1, 2011, November 1, 2012 and December 11, 2013

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III

- Data Brochure tekmarnet 4 Thermostat 542e

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Logamax plus GB142. Applications Manual. Gas condensing boiler

Installation & Operation Manual

Installation & Operation Manual

hydronic S Y S T E M S & C O M P O N E N T S

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

Melt Demand. Idle Demand. WWSD Water. Melting. Stop. Do not apply power. Do not apply power. 5 Brn/ Slab. Com tn2. Input. Melt/Idle.

4 Wiring Brochure Wiring and

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

Air conditioning plant with 1 hot water preheater, 1 spray humidifier, 1 chilled water cooling coil and 1 hot water reheater N.Q1 B2 N.X1 B1 N.

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

Transcription:

EFFECTIVE: arch 1, 2004 Taco Radiant ade Easy Application Guide Radiant ixing Block Products & Applications PA09 SUPERSEDES: New OVERVIEW Radiant ixing Block The Taco Radiant ixing Block (RB) is a complete injection mixing system. Integral to the unit is a variable speed injection circulator, constant speed system circulator, air elimination, and the electronics to drive it all. With only four piping connections needed, the RB greatly reduces the time and Figure A Piping, Pumps & Controls are Alll Included in the RB. RB - Radiant ixing Block space required for installation (see Figure A).The RB can be set up to operate as an outdoor reset control or a setpoint control with or without delta T limiting, creating flexibility never seen before in a single unit. Conventional Injection ixing Piping OPERATION A C B D Hot water from the boiler loop enters the RB at the port (A).The cooler return water from the radiant loops enters at the System Return port (B). In the middle of these two ports, any air in the system is purged through the integral Taco Hy-Vent.The injection circulator varies in speed to blend the two temperatures, injecting the excess required temperature back through the Return port (C). The constant speed system circulator delivers the required blended water temperature to the radiant loop through the Radiant port (D). Features: All-in-one injection piping, pumping, air elimination & control package Only 4 pipe connections required Plug-in low voltage connections Solid state microprocessor design Greatly decreases installation time Substantial space savings Line cord included, hard wire option Bronze casing for open or closed systems Replaceable cartridge design aintenance free, wet-rotor circulators 2 operation modes: outdoor reset and setpoint with or without delta T with limiting Powered or unpowered demand signal Integral check valve ain system pump contact 100% pump operation / control override switch Automatic pump exercise Adjustable reset ratio Warm weather shutdown control or enable setting protection Large LCD display C or F and 2 strap-on sensors included

CONTROL STRATEGY Reset ode of Operation In order to properly control a hot water heating system, the amount of heat supplied to the building must equal the amount of heat lost by the building.the amount of heat delivered into a building depends on the temperature of the water in the heating unit and the surface area of the heating unit. Heating units with a small surface area, such as baseboard radiators, require a higher water temperature than heating units with a larger surface area such as radiant floors. The amount of heat lost from a building depends on the outdoor temperature. As the outdoor temperature becomes colder, the amount of heat a building loses increases. The operation of a hot water heating system can generally be improved by adjusting the supply water temperature to the system as the outdoor temperature changes. Using this approach, the heat input to the building can be matched to the heat lost from the building. This method of controlling the supply water temperature to a heating system greatly improves the comfort of the system and is known as Reset. When a Taco is connected to the Radiant ixing Control (RC), the RC provides outdoor reset. When operating in the outdoor reset mode of operation, the installer must set the Design Temperature and the Design Temperature in order to establish the relationship between the outdoor temperature and the supply water temperature.this is known as setting the Heating Curve. Setpoint and Setpoint with Delta T ax ode of Operation In certain applications, it is desirable to maintain a fixed supply water temperature.this type of application is a setpoint application. Examples of setpoint applications include heat pump loops, reheat coils and floor warming. In specialized applications, such as snow melting, it is desirable to limit the rate of temperature increase in the system from the system s starting temperature to its operating setpoint.this is desired in order to prevent thermal shock of the system.this type of application is Setpoint with Delta T ax. DESIGN Design Procedure 1. Using the pump curve located below, ensure that the System Pump of the Radiant ixing Block will provide adequate flow for the system in which it is to be installed. 2. Using the table or equation below, determine the required flow rate for the Injection Pump. 3. Using the pump curve located below, ensure that the Injection Pump of the Radiant ixing Block will provide adequate flow for the system in which it is to be installed. SYSTE PUP CURVE INJECTION PUP CURVE 18 16 14 18 16 14 HEAD (ft) 12 10 8 HEAD (ft) 12 10 8 6 4 2 6 4 2 0 PA09 2 0 5 10 15 FLOW (gpm) 0 0 5 10 15 FLOW (gpm)

Required Injection Pump Flow Rate Tb = Temperature Ts = Radiant Temperature BTU s Injection Flow Rate (GP) = (Tb - Ts) x 500 Required Injection Flow Rate (GP) Tb - Ts BTU s x 1000 20 40 60 80 100 120 100 0.4 0.8 1.2 1.6 2.0 2.4 80 0.5 1.0 1.5 2.0 2.5 3.0 60 0.7 1.3 2.0 2.7 3.3 4.0 40 1.0 2.0 3.0 4.0 5.0 20 2.0 4.0 OPERATION Reset When the Radiant ixing Control (RC) receives a and it is not in a warm weather shutdown (WWSD), the RC turns on the system pump and calculates a ixing Target temperature. The variable speed injection pump is then operated to maintain the ixing Target temperature at the mixing supply sensor. The boiler contact operates as described in the Operation section. The RC also provides boiler protection as described in the Operation section. The RC requires a demand signal before it will begin operation. The RC can use either a powered or an unpowered demand signal. Once a demand signal is received, the RC displays the demand pointer in the display and operates as described above. Powered The RC recognizes a Powered Signal when 24 V (ac) is applied across the Com and Heat Dem terminals. Unpowered The RC recognizes an Unpowered signal when a switch is closed between the Com and Heat Dem terminals. System Pump Operation The RC has an internal system pump contact.this contact turns on when the RC has a mixing demand and is not in a WWSD.The integrated system pump as well as an external boiler pump may be controlled by this relay. By providing proper flow in the boiler loop, the boiler temperature can be accurately controlled based on the mixing load. Powered C 24 V (ac) R Unpowered Boil Out Switch Boil Out Switch Com Heat Dem Com Heat Dem Heating Curve Settings In order to establish the heating curve, the RC must be given two points to work with.the first point is the Reset Starting Point and the second point is the Design Condition. Reset Starting Point The Reset Starting Point for the RC is fixed at 72 F. This means that when the outdoor temperature is 72 F, the RC calculates a required supply water temperature (ix Target) of 72 F. Starting Point WWSD Reset ix aximum Design ix Design 70 60 50 40 30 20 10 0-10 -20 Temperature ( F) 150 140 130 120 110 100 90 80 70 60 F Temperature ( F) PA09 3

Design Conditions The design conditions represent the supply water temperature required to satisfy the heating system on the typical coldest day of the year.these are the conditions that are used when calculating the size of the heating equipment needed to heat the building.the Design Conditions are made up of an outdoor temperature ( Design) and a supply water temperature (Design ). Design The Design temperature is the average coldest day of the year for the area in which the building is located. Design The Design temperature is the supply water temperature that is required to heat the building when the outdoor air temperature is as cold as the Design temperature. aximum System Some systems, such as hydronic radiant floor heating, may require the maximum supply water temperature to be limited in order to protect certain system components from high temperatures.the RC has a aximum setting that can be used to limit the maximum temperature that the control is allowed to use for a ixing Target (IX TRG) temperature. inimum System Some applications, such as floor warming, may require the minimum supply water temperature to be limited in order to provide a certain level of occupant comfort.the RC has a inimum setting that can be used to limit the minimum temperature that the control is allowed to use for a ixing Target (IX TRG) temperature.this minimum applies as long as the RC has a demand and is not in WWSD. Warm Weather Shut Down (WWSD) When the outdoor temperature is warmer than the WWSD setting, the RC turns off the boiler and the variable speed injection pump. If a demand is received while the RC is in a WWSD, the RC indicates that the demand has been received by displaying the pointer however, the IX TRG remains as - - - The RC has a freeze protection feature that does not allow the supply water temperature to drop below 35 F (2 C) as long as there is a mixing demand signal. Setpoint and Delta T If the RC is to operate as a setpoint control, the Design temperature must be set to OFF and the ixing Target temperature must be set to the desired temperature. If the RC is to operate as a Delta T control, a mixing return sensor must be installed, the Design temperature must be set to OFF and both the Delta T ax setting and the ixing Target temperature must be set to the desired temperature. In both of these applications, the outdoor sensor is not to be installed. When the RC receives a, the system pump is turned on. If the Delta T ax setting is set to OFF, the variable speed injection pump is operated to maintain the mixing supply sensor at the ixing Target temperature set by the installer. If the Delta T ax setting is not set to off, the variable speed injection pump is operated to maintain the mixing supply sensor at either the ixing Return temperature plus the Delta T ax setting or the ixing Target temperature set by the installer whichever is lower. The boiler contact operates as described in the Operation section. The RC also provides boiler protection as described in the Operation section. The RC requires a demand signal before it will begin operation.the RC can use either a powered or an unpowered demand signal. Once a demand signal is received, the RC displays the demand pointer in the display and operates as described above. Powered The RC recognizes a Powered Signal when 24 V (ac) is applied across the Com and Heat Dem terminals. Unpowered The RC recognizes an Unpowered signal when a switch is closed between the Com and Heat Dem terminals. System Pump Operation The RC has an internal system pump contact.this contact turns on when the RC has a mixing demand.the system pump as well as an external boiler pump may be controlled by this relay. By providing proper flow in the boiler loop, the boiler temperature can be accurately controlled based on the mixing load. PA09 4 Powered C 24 V (ac) R Unpowered Boil Out Switch Boil Out Switch Com Heat Dem Com Heat Dem

Design The Design temperature must be set to OFF. ixing Target The ixing Target temperature is set to the desired operating temperature of the system. Delta T ax The Delta T ax temperature is set to the maximum temperature difference that is desired between the mixing return temperature and the mixing supply temperature. In order to adjust this setting, a mixing return sensor must be connected to the control. Setpoint Delta T aximum 150 120 140 110 ix = ix Target 130 120 110 100 90 80 Temperature ( F) ix Target ix ix Return aximum Delta T 100 90 80 70 60 50 Temperature ( F) 70 40 Time 60 F Start Time 30 F BOILER OPERATION The RC operates the boiler in two basic modes of operation.the RC can either Control the boiler or Enable the boiler.the mode of operation is determined by the location.the boiler sensor location is determined using the DIP switch on the back of the circuit board. If the DIP switch is set to ON, the boiler sensor is to be located on the boiler supply. If the DIP switch is set to OFF, the boiler sensor is to be located on the boiler return. If the DIP switch is set to On, the RC will Control the boiler. If the DIP switch is set to Off, the RC will Enable the boiler. If the has not been installed, the RC will Enable the boiler. Control Injection ixing Control When the RC controls the boiler, the RC opens and closes the boiler contact in order to control the temperature of the boiler supply water temperature. When the RC is controlling the boiler temperature, the RC will determine the boiler supply water temperature that is required to satisfy the demands of the system.the RC will also determine a differential that is sufficient to minimize short cycling of the boiler.the RC will then cycle the boiler using these parameters. Differential An on / off boiler must be operated with a differential in order to prevent short cycling. When the supply water temperature drops 1 2 of the differential below the required boiler supply temperature, the boiler is turned on.the boiler is then kept on until the supply water temperature rises 1/2 of the differential above the required boiler supply temperature. If the differential is too wide, there can be large supply water temperature swings; however, if the differential is too narrow, the boiler short cycles and operates inefficiently. This control automatically calculates the boiler differential in order to achieve an appropriate balance between temperature swings and boiler efficiency.this also permits the control to adapt to changing loads and conditions.the RC only operates the boiler once the output of the injection circulator exceeds 10% of flow. 1 2 ON OFF PA09 5

Enable When the RC Enables the boiler, the RC opens and closes the boiler contact based on the output of the variable speed injection pump.the actual temperature and cycling of the boiler is then determined by other controls or the aquastats on the boiler itself.when operating in the boiler enable mode, the boiler contact turns on once the variable speed output exceeds 25%.The boiler contact shuts off if the output of the variable speed drops below 5% for more than three minutes or if the demand is removed from the RC. Protection ( inimum) Cool water is often returned to the boiler from low temperature radiant floor heating systems or when the heating system is recovering from night setback.this cool boiler return water may cause the boiler to operate at such a low temperature that the flue gases condensate. Alternatively, when the boiler surfaces are hot due to previous loads such as domestic hot water generation, the large temperature difference (Delta T) between the boiler and its return water can cause the boiler to become thermally shocked. Proper protection of the boiler under these circumstances is required. When a boiler sensor is connected to the control, the RC is capable of providing boiler protection. When providing boiler protection, the RC limits the output of the variable speed injection pump in order to reduce the amount of cool water being returned to the boiler. This allows the boiler temperature to increase to a point that avoids flue gas condensation. Protection with Enable When the is set to the Return setting the control begins to back off the variable speed injection pump when the boiler temperature drops below the inimum Setting. Protection with Control When the is set to the setting the control begins to back off the variable speed injection pump when the boiler temperature drops 1/2 of the Differential below the inimum Setting. Note: If a boiler sensor is not installed, the RC cannot provide boiler protection. INSTALLATION For installations where boiler protection is NOT required, the boiler sensor does not need to be installed. RB - Radiant ixing Block RB - Radiant ixing Block, ultiple Zone Valves Radiant anifold - Return Radiant anifold - RB - Radiant ixing Block, ultiple Zone Circulators RB - Radiant ixing Block PA09 6

RB - Radiant ixing Block, ultiple Temperature System RB - ultiple Radiant ixing Blocks, ultiple Zone Valves RB - Radiant ixing Block, ultiple Temperature System RB - Radiant ixing Block, ultiple Temperature System RB - ultiple Radiant ixing Blocks, ultiple Zone Circulators Radiant anifold - Return Radiant anifold - RB - Radiant ixing Block, ultiple Temperature System Radiant anifold - Return Radiant anifold - Radiant anifold - Return Radiant anifold - RB - ultiple Radiant ixing Blocks RB - ultiple Radiant ixing Blocks PA09 7

Radiant anifold - Return Radiant anifold - RB - ultiple Radiant ixing Blocks, ultiple Temperature System Radiant anifold - Return Radiant anifold - RB - ultiple Radiant ixing Blocks, ultiple Temperature System Setpoint with Delta T ax. Operation ode Return Return RB - Radiant ixing Block RB - Radiant ixing Block, ultiple Zone Valves Return Return RB - ultiple Radiant ixing Blocks Radiant ade Easy TACO, INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 FAX: (401) 942-2360. TACO (Canada), Ltd., 6180 Ordan Drive, ississauga, Ontario L5T 2B3. Telephone: 905/564-9422. FAX: 905/564-9436. Visit our web site at: http://www.taco-hvac.com Printed in USA Copyright 2004 TACO, Inc. PA09 8