- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1
|
|
- Anis Alexander
- 5 years ago
- Views:
Transcription
1 - Application Boiler Control & One Stage Setpoint Control 150 A -1 07/99 echanical Remote Display odule () 040 Outdoor Sensor () ODE 1 Class II Transformer 120 V (ac) 24 V (ac) R1 A2 Z1 Z2 Z3 T1 T2 T3 Z7 P4 S4 Heat Exchanger P3 DHW Tank S3 Low / High Fire Boiler Z3 Z3 Z3A 1 B1 Electrical = Pool or Spa High Limit Aquastat A2 = DHW High Limit Aquastat = Remote Display odule 040 (optional) = Boiler Pump = DHW Pump P3 = Pool or Spa Pump P4 = Pool or Spa Recirc. Pump R1 = Relay 003 = Boiler sensor 071 = Outdoor sensor 070 S3 = DHW Sensor 071 S4 = Pool or Spa Sensor 071 T1,.., T3 = Thermostats U1 = tekmar Timer 031 (optional) Z1,.., Z3 = Zone Valve otor End Switches 10A 10A 10A 10A Do not apply power Boiler ComDHWSetp Demand DemDemDem Power N L Boil DHW Pmp/Vlv 1 Stage Stage Boiler Low Boiler High tn1 / Com 10K UnO Com DHWBoil Out tn2 Sw U1 S3 PW 8A On Power Off C- R+ Com N/O 8A 150 No Power N/C Sensor S4 120 V (ac) L N Class II Transformer 24 V (ac) C T1 T2 T3 R Z1 Z2 Z3 A2 P R Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added. 1 of 8 Copyright 1999 A -07/99
2 System Operation A -1 07/99 The Boiler Control provides partial or full outdoor reset to three (or more) boiler zones. The Setpoint Control 150 controls the temperature of the pool or spa. The boiler is operated at the temperature required in order to satisfy the loads. The also controls the supply of heat to an indirect Domestic Hot Water (DHW) tank. An optional Remote Display odule (RD) provides remote adjustment and monitoring of the control. Heat Source Details The heat source can be either a high mass or low mass non-condensing boiler or low temperature boiler. If using a low temperature boiler, refer to sections C3 and of the Data Brochure for additional information. Piping Details Thermostat controlled zone valves are piped into the boiler loop. The boiler pump () provides circulation through these zones when heat is required. The pool or spa heat exchanger is piped into the boiler loop and the temperature is controlled through a pump (P3). Heat is supplied to the DHW tank through a DHW pump (). DHW Demand When the DHW sensor (S3) calls for heat, the turns on the DHW pump () and raises the boiler water temperature to at least the DHW TANK setting plus 40 F (22 C). The control maintains the DHW tank temperature at the DHW TANK setting. The control can provide DHW priority (refer to sections C2 and C3 of the Data Brochure) by turning off the boiler pump (). Once the DHW demand is removed, the performs a DHW Post Purge and possibly a ixing Purge. Setpoint Demand The Setpoint Control 150 cycles relay R1 in order to control the heat exchanger pump (P3) and maintain the pool or spa temperature. When the 150 requires heat, it provides a Setpoint Demand to the through relay R1. The increases the boiler temperature to at least the SETPOINT setting. The control can provide Setpoint priority (refer to sections C3 and of the Data Brochure) by turning off the boiler pump (). Boiler Demand When heat is required in the boiler zones, the zone valve end switches send a Boiler Demand to the. The turns on the boiler pump (). The boiler supply water temperature is based on the Reset Ratio or Characterized Heating Curve settings. The boiler is staged to satisfy the required boiler supply water temperature. Whenever the boiler is fired, the aims to increase the boiler temperature to at least the Boil IN setting. All control functions and specifications are listed in the Product Catalog I 000 and the Data Brochure D. Required aterial and Essential Control Settings Required tekmar Products Boiler Control One Stage Setpoint Control 150 Universal Sensor x tekmar DPDT Relay 003 Optional tekmar Products Remote Display odule (RD) 040 Timer 031 Essential Application Control Settings (Adjust enu) Item Field Setting ODE 1 STAGE 1 AUTO STAGE 2 AUTO DHW SENS DHW ROTATE OFF Note For all other settings, refer to the Data Brochure D and D 150. Control Systems tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: rd Street Vernon, B.C. Canada V1T 4K7 Tel. (250) Fax. (250) Web Site: Product design, software and literature are Copyright 1999 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 2 of 8 All specifications are subject to change without notice. Printed in Canada. A -1 07/99.
3 Boiler Control - Application A -2 07/99 echanical Remote Display odule () 040 Outdoor Sensor () 070 ODE V (ac) T T T P V1 Z1A Z1A B3 B3A Electrical = Remote Display odule 040 (optional) = Boiler Pump = Boiler Sensor 071 = Outdoor Sensor 070 T = Thermostatic Radiator Valve U1 = tekmar Timer 031 (optional) V1 = Balancing valve, globe valve, or pressure differential valve 10A 10A 10A 10A Do not apply power Boiler ComDHWSetp Demand DemDemDem Power N L Boil DHW Stage Stage Pmp/Vlv tn1 / Com 10K UnO Com DHWBoil Out tn2 Sw Boiler #1 U1 Boiler #2 120 V (ac) L N Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added. 3 of 8 Copyright 1999 A -07/99
4 System Operation A -2 07/99 The Boiler Control provides partial or full outdoor reset to three (or more) thermostatic radiator valve zones. Constant circulation to the zones is provided by the boiler pump (). The boilers are staged as required to provide the supply water temperature that satisfies the loads. An optional Remote Display odule (RD) provides remote adjustment and monitoring of the control. Heat Source Details The heat source can be either high mass or low mass non-condensing or low temperature boilers. Piping Details Thermostatic radiator valve (TRV) zones are piped into the boiler loop. A pressure differential valve (V1) provides a bypass for the boiler pump () in the event that most of the TRV s are closed. The boilers are piped using parallel primary / secondary in order to provide equal and isolated flow through each boiler. Boiler Demand When the outdoor air temperature is below the Warm Weather Shut Down (WWSD) setting, the turns on the boiler pump (). The boiler supply water temperature is based on the Reset Ratio or Characterized Heating Curve settings. The boilers are staged to satisfy the required boiler supply water temperature. Whenever the boilers are fired, the aims to increase the boiler supply water temperature to at least the Boil IN setting. All control functions and specifications are listed in the Product Catalog I 000 and the Data Brochure D. Required aterial and Essential Control Settings Required tekmar Products Boiler Control Optional tekmar Products Remote Display odule (RD) 040 Timer 031 Essential Application Control Settings (Adjust enu) Item Field Setting ODE 1 STAGE 1 AUTO STAGE 2 AUTO Note For all other settings, refer to the Data Brochure D. Control Systems tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: rd Street Vernon, B.C. Canada V1T 4K7 Tel. (250) Fax. (250) Web Site: Product design, software and literature are Copyright 1999 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 4 of 8 All specifications are subject to change without notice. Printed in Canada. A -2 07/99.
5 Boiler Control - Application A -3 07/99 echanical Class II Transformer Remote Display odule () 040 Outdoor Sensor () 070 ODE V (ac) 24 V (ac) S3 Z1 Z2 Z3 R1 T1 R2 T2 R3 T3 B4 Z5A Z5A Z5B D9 Electrical = DHW High Limit Aquastat = Remote Display odule 040 (optional) = Boiler Pump = DHW Pump R1,.., R3 = Relay 003 = Boiler Sensor 071 = Oudoor Sensor 070 S3 = DHW Sensor 071 T1,.., T3 = Thermostats U1 = tekmar Timer 031 (optional) Z1,.., Z3 = Zone Pumps 120 V ac Class II Transformer C 24 V ac L N R T1 T2 T R R2 R3 Z1 Z2 Z3 10A 10A 10A 10A Do not apply power Boiler ComDHWSetp Demand DemDemDem Power N L Boil DHW Stage Stage Pmp/Vlv Boiler #1 Boiler # tn1 / Com 10K UnO Com DHWBoil Out tn2 Sw U1 S3 Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added. 5 of 8 Copyright 1999 A -07/99
6 System Operation A -3 07/99 The Boiler Control provides partial outdoor reset to three (or more) boiler zones. The also controls the supply of heat to an indirect Domestic Hot Water (DHW) tank. The boilers are staged as required to provide the supply water temperature that satisfies the loads. An optional Remote Display odule (RD) provides remote adjustment and monitoring of the control. Heat Source Details The heat source can be either high mass or low mass non-condensing boilers. Piping Details Thermostat controlled zone pumps are piped off the boiler loop as a secondary loop. Heat is supplied to the DHW tank through a DHW pump (). The boilers are piped in reverse return in order to ensure equal flow through both boilers. The boiler pump () provides flow through the boilers and ensures flow past the DHW tank take-off and the zone pump take-off. DHW Demand When the DHW sensor (S3) calls for heat, the turns on the DHW pump () and the boiler pump () and raises the boiler water temperature to at least the DHW TANK setting plus 40 F (22 F). The control maintains the DHW tank at the DHW TANK setting. Once the DHW demand is removed, the performs a DHW Post Purge and possibly a ixing Purge. Boiler Demand When heat is required in the heating zones, the zone pump relays send a Boiler Demand to the. The turns on the boiler pump (). The boiler supply water temperature is based on the Reset Ratio or Characterized Heating Curve settings. The boilers are staged to satisfy the required boiler supply water temperature. Whenever the boilers are fired, the aims to increase the boiler supply water temperature to at least the Boil IN setting. All control functions and specifications are listed in the Product Catalog I 000 and the Data Brochure D. Required aterial and Essential Control Settings Required tekmar Products Boiler Control 3 x tekmar DPDT Relay 003 Optional tekmar Products Remote Display odule (RD) 040 Timer 031 Essential Application Control Settings (Adjust enu) Item Field Setting ODE 1 STAGE 1 AUTO STAGE 2 AUTO DHW THRU VALV DHW SENS DHW Note For all other settings, refer to the Data Brochure D. Control Systems tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: rd Street Vernon, B.C. Canada V1T 4K7 Tel. (250) Fax. (250) Web Site: Product design, software and literature are Copyright 1999 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 6 of 8 All specifications are subject to change without notice. Printed in Canada. A -3 07/99.
7 Boiler Control - Application A -4 07/99 echanical Remote Display odule () 040 ODE 2 Alarm 120 V (ac) 3 D6 B4 Electrical = DHW High Limit Aquastat (optional) = Remote Display odule 040 (optional) = Boiler Pump = DHW Recirc. Pump = Boiler Sensor 071 = DHW Sensor 071 U1 = tekmar Timer 031 (optional) 10A 10A 10A 10A Do not apply power Boiler ComDHWSetp Demand DemDemDem Power N L Boil DHW Stage Stage Pmp/Vlv tn1 / Com 10K UnO Com DHWBoil Out tn2 Sw Boiler #1 U1 Alarm Boiler #2 N/O N/C 120 V (ac) L N Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added. 7 of 8 Copyright 1999 A -07/99
8 System Operation A -4 07/99 The Boiler Control provides control of two boilers for a dedicated Domestic Hot Water (DHW) storage system. An optional Remote Display odule (RD) provides remote adjustment and monitoring of the control. Heat Source Details The heat source can be high mass or low mass non-condensing or low temperature boilers or any boilers designed for this type of application. Piping Details The boilers are piped in reverse return providing equal flow through each boiler. The DHW recirculation loop pump () provides constant hot water flow past the fixtures. DHW Demand When the DHW sensor () calls for heat, the turns on the boiler pump () and raises the boiler water temperature to at least the DHW TANK setting plus 40 F (22 C). The control maintains the DHW tank temperature at the DHW TANK setting. The RD is capable of sounding an alarm if the DHW tank overheats. When the DHW high limit aquastat () is triggered, the receives an external DHW Demand. When the receives the demand, a DHW Error (DHW ERR) is registered and the alarm contact of the RD is closed. To clear this error, refer to the Data Brochure D. Recirculation The recirculation pump () operates continuously when the control is in the Occupied mode. The recirculation pump () is turned off when the control is in the UnOccupied mode. All control functions and specifications are listed in the Product Catalog I 000 and the Data Brochure D. Required aterial and Essential Control Settings Required tekmar Products Boiler Control Optional tekmar Products Remote Display odule (RD) 040 Timer 031 Essential Application Control Settings (Adjust enu) Item Field Setting ODE 2 STAGE 1 AUTO STAGE 2 AUTO DHW SENS DHW Note For all other settings, refer to the Data Brochure D. Control Systems tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: rd Street Vernon, B.C. Canada V1T 4K7 Tel. (250) Fax. (250) Web Site: Product design, software and literature are Copyright 1999 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 8 of 8 All specifications are subject to change without notice. Printed in Canada. A -4 07/99.
- Application Boiler Control 260
- Application Control A -1 03/09 echanical Outdoor Sensor (S2) 070 120 V (ac) 24 V (ac) T3 T2 T1 Sensor (S1) 082 Electrical = Pump S1 = Sensor 082 S2 = Outdoor Sensor 070 T1,..., T3 = Thermostats U1 =
More information- Data Brochure Addendum
- Data Brochure ddendum Control 264 - ddition of Modes and Setpoint Modes D 264 10/03 The tekmar Control 264 has been modified to include the following features: demand for loads alarm New Setpoint operation
More information- Data Brochure Addendum
- Data Brochure ddendum Control 268 - ddition of Modes and Setpoint Modes D 268 10/03 The tekmar Control 268 has been modified to include the following features: demand for loads alarm New Setpoint operation
More information- Essay Control Functions and Benefits
- Essay Control Functions and Benefits E 005 07/01 A hydronic heating control system performs many complex and important functions. Each of these functions provide benefits that make the system comfortable,
More information- Data Brochure Universal Reset Module 423
- Data Brochure Universal Reset Module 423 D 423 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More information- Data Brochure Universal Reset Module 422
- Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More information- Data Brochure D 260. Boiler Control /09
- Data Brochure Boiler Control 260 D 260 03/09 The Boiler Control 260 is designed to control a single stage heat source in order to provide outdoor reset or Domestic Hot Water () operation. The control
More informationBoiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand
Date Code - Data Brochure Universal Reset Control 374 D 374 10/03 The tekmar Universal Reset Control 374 is designed to maximize the comfort and effi ciency provided by a hydronic heating system. The control
More informationThe Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic
R Vie Menu % % 1 2 Item F! WWS Vie Menu % % 1 2 Item F! WWS 70 LR 58233 E150539 Universal Reset Control 363 - Data Brochure D 363 12/08 The Universal Reset Control 363 is a microprocessor based control
More information- Data Brochure Boiler Control 274
- Data Brochure Boiler Control 274 274_D 03/17 The Boiler Control 274 operates up to four on/off boilers to provide outdoor reset operation, domestic hot water and setpoint operation with priority. When
More informationU538 12/11. Zoning. Replaces: 08/10. tekmarnet 4 Thermostat 538. User Manual. 1 of U /11
tekmarnet 4 Thermostat 538 User Manual Zoning U538 12/11 Replaces: 08/10 1 of 12 2011 U 538-12/11 This brochure will provide you with the information you need to benefit the most from your tekmarnet thermostat.
More informationBetter Design, Better Control, Better Systems.
Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning
More information- Data Brochure Boiler Control 264
- Data Brochure Boiler Control 264 D 264 11/03 The tekmar Boiler Control 264 can control the supply water temperature from up to 4 on / off stages based on outdoor temperature, control for Domestic Hot
More information552_U 09/14. tekmarnet Thermostat 552 Zoning Replaces: 08/11. User Manual. 1 of 12. A Watts Water Technologies Company _U - 09/14
552_U 09/14 tekmarnet Thermostat 552 Zoning Replaces: 08/11 User Manual 1 of 12 This brochure will provide you with the information you need to benefit the most from your tekmarnet thermostat. Please visit
More informationMODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL
MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL The SF-10 Temperature Control () is an efficient boiler operator with a digital LCD display with backlight, a boiler pump output, and an alarm. The
More information- Data Brochure Boiler Control 268
- Data Brochure Boiler Control 268 D 268 11/10 The tekmar Boiler Control 268 can control the supply water temperature from up to 9 on / off stages based on outdoor temperature, control for Domestic Hot
More information- Data Brochure Mixing Control 360
- Data Brochure Mixing Control 360 D 360 03/09 The Mixing Control 360 is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset or setpoint operation. The
More informationInstallation & Operation Manual
Boiler Control 275 Installation & Operation Manual Multi-Staging D 275 01/12 Replaces:03/09 The Boiler Control 275 is designed to stage up to four condensing or non-condensing, modulating or on-off boilers
More information- Data Brochure Boiler Control 264e
- Data Brochure Boiler Control 264e D 264e 09/09 The kanmor Boiler Control 264e can control the supply water temperature from up to 4 on / off stages based on outdoor temperature, control for Domestic
More informationWWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223
Dial the desired duration of the period. Press start button at the time of day you want the UnOcc. period to begin. light turns on. 0 = always = always Pump / Vlv System Pump Zone / Cooling NRTL/C LR 58
More informationDHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override
Date Code - Data rochure oiler Control 265 D 265 10/03 The tekmar oiler Control 265 can control the supply water temperature on up to three modulating boilers based on outdoor temperature or setpoint requirements.
More informationMODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL
MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL The EM-10 Boiler Temperature Control (BTC) is an efficient boiler operator with a digital LCD display with backlight, a boiler pump
More information- Data Brochure Universal Reset Control 364
70 7 8 9 - Data Brochure Universal Reset Control 364 D 364 07/01 The Universal Reset Control 364 is designed to maximize the comfort and efficiency provided by a hydronic heating system. The control automatically
More information- Data Brochure Mixing Control 361
TIME PRGM 1 2 AMPM UN OVR S M T W T F S - Data Brochure Mixing Control 361 D 361 05/00 The Mixing Control 361 is designed to control the supply water temperature to a hydronic system in order to provide
More information- Data Brochure Steam Control 279
- Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the
More informationHydronic & HVAC Control Systems
tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better
More information- User Brochure tekmarnet 4 Setpoint Control 161
- User Brochure tekmarnet 4 Setpoint Control 161 U 161 08/07 Congratulations on the purchase of your tekmar setpoint control with communication. The setpoint control combines easy-to-use programming with
More information- Data Brochure D 261. Boiler Control 261
TIME PRGM 1 2 AMPM UNOCC OVR S M T W T F S - Data Brochure Boiler Control 261 D 261 03/09 The Boiler Control 261 is designed to control two separate on / off boiler stages (or one low / high fire) in order
More information- Data Brochure Mixing Reset Module 421
- Data Brochure Mixing Reset Module 421 D 421 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in 4 Wiring
More informationControl Panel Checklist
Control Panel Checklist Versatronik -C Panel Checklist Option Selection for Control Panel Quotes Checklist Control Panel Checklist Section 1 General Information Customer name Phone number Fax number Email
More informationSC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS
FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS SC-3 Controller MODULAR BOILER CONTROLLER SERIES INSTALLATION AND OPERATING INSTRUCTIONS SC-3 Applications Space Heat Systems With Outdoor
More informationZoning Solutions. Thermostats & Wiring Centers Designed to Maximize Indoor Comfort. A Watts Water Technologies Company
Zoning Solutions Thermostats & Wiring Centers Designed to Maximize Indoor Comfort HVAC Systems Multi-Staging Alternative Energy Zoning Snow Melting Setpoint A Watts Water Technologies Company Zoning in
More informationInstallation & Operation Manual
tekmarnet 2 House Control 400 Installation & Operation Manual D 400 09/10 HVAC Systems Replaces: 01/10 Introduction The House Control 400 is designed to operate as part of a complete hydronic heating system
More informationInstallation & Operation Manual
tekmarnet 2 House Control 400 Installation & Operation Manual D 400 09/13 HVAC Systems Replaces: 09/10 Introduction The tn2 House Control 400 is designed to operate all of the mechanical equipment in a
More informationRadiant Mixing Block
EFFECTIVE: arch 1, 2004 Taco Radiant ade Easy Application Guide Radiant ixing Block Products & Applications PA09 SUPERSEDES: New OVERVIEW Radiant ixing Block The Taco Radiant ixing Block (RB) is a complete
More informationHeatronic 4000 IO Heatronic /04 en-us. Features. 4 boiler control, DHW, BACnet and Modbus. Installation/Operating instructions (IO)
The is designed to operate up to four boilers to accurately maintain a target water temperature. The Heatronic 4000 operates both condensing & non-condensing boilers that are either modulating, single
More informationc0094 form 2. Project Identification Year: 2001 Project nº: 910
1. History of processing of this form v1 Jul 19, 2001 by JN RBI 4 Stage Boiler Control. v2 Aug 7, 2001 by JN Packaging of BTC and 071 Sensors, and finalized mounting option, etc. v3 Aug 29, 2001 by JN
More informationB-40/B-41 Modulating Temperature Controller
INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N
More information- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!
- Data Brochure Programmable Thermostat 510 and 511 D 510 02/12 Table of Contents Display / Keypad Operation... pg 1 Display Symbols... pg 2 General... pg 2-3 Sequence of Operation... pg 4 Installation
More information- Data Brochure Mixing Control 360e
- Data Brochure Mixing Control 360e D 360e 06/11 The Mixing Control 360e is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset or setpoint operation.
More informationInstruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA
Instruction Sheet PC2 1 Two Stage Reset & Control SUPERSEDES : 102-106, dated June 1, 2000 EFFECTIVE: March 1, 2004 Plant ID# 9300-1059 Item 102-106 The PC2-1 is a microprocessor-based control designed
More informationprestige Control Application Supplement - TriMax
prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More informationprestige Control Application Supplement - ACVMax
2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory
More informationInstallation & Operation Manual
tekmarnet 2 House Control 403 Installation & Operation Manual D 403 07/11 HVAC Systems Replaces: 09/10 Introduction The House Control 403 is designed to operate as part of a complete hydronic heating system
More informationInstallation & Operation Manual
tekmarnet 2 House Control 402 Installation & Operation Manual D 402 09/10 HVAC Systems Replaces: 01/10 Introduction The House Control 402 is designed to operate as part of a complete hydronic heating system
More informationControl Application. Supplement - ACVMax
prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More informationInstallation & Operation Manual
tekmarnet 2 House Control 406 Installation & Operation Manual 406_D 11/12 Alternative Energy Replaces: 12/11 Introduction The tn2 House Control 406 is designed to operate the equipment in a 2-pipe, single
More informationInstallation & Operation Manual
557_D tekmarnet Thermostat 557 09/14 Zoning Replaces: 09/13 Installation & Operation Manual Introduction The tekmarnet Thermostat 557 is a communicating touchscreen thermostat designed to operate either:
More informationHeat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.
Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow
More information- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions
- Brochure tekmarnet 4 Thermostat 542 D 542 06/05 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough In Wiring Rough-in 4 Wiring
More information- Data Brochure tekmarnet 4 Thermostat 542e
- Data Brochure tekmarnet 4 Thermostat 542e D 542e 03/08 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in
More informationDual Mixing Application
HBX MIXING APPICATION The CPU-000 configured as a Mixing Control allows for mixing of hitemp boiler (supply) water with lower temp system water, bringing several benefits to a hydronic design and installation.
More information4 Wiring Brochure Wiring and
- Brochure tekmarnet 4 Thermostat 544 D 544 06/05 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough In Wiring Rough-in 4 Wiring
More informationprestige Control Application Supplement - TriMax
prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More informationHPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations
Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control
More informationSC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS
SC-9 Controller MODULAR BOILER CONTROLLER SERIES INSTALLATION AND OPERATING INSTRUCTIONS SC-9 Applications Space heat systems with outdoor reset Constant temperature setpoint control Any of these in combination
More information- Installation & Operation Manual Boiler Control 256
TIME PRGM 1 2 AMPM UNOCC OVR S M T W T F S - Installation & Operation Manual Boiler Control 256 D 256 07/11 The Boiler Control 256 is designed to control a single stage heat source in order to provide
More informationBosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler
WARNING: Improper installation, setup, modification, operation or maintenance of the heating system can cause personal injury and property damage. Follow each appliances' instructions precisely. For assistance
More informationDaikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)
March 15, 2011 Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5) Our Daikin Altherma project involves integrating an indoor unit (EKHBX054BA3VJU) with an existing domestic hot
More informationInstruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators
Instruction Sheet Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators 102-358 SUPERSEDES: May 1, 2010 EFFECTIVE: October 1, 2010 Plant ID# 001-3921 The Variable Speed - Setpoint 00 Cartridge
More informationWIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873
WIRIG GUIDE The ZSR101 is a versatile single relay control with two outputs for operating a 120 VAC with boiler enable, or two 120 VAC devices without boiler enable. Features include rear knock outs for
More informationInstallation & Operation Manual
Humidity & Temperature Sensor 086 Accessories 086_D 08/12 Replaces: New Installation & Operation Manual Introduction The Humidity & Temperature Sensor 086 can be connected to select tekmar thermostats
More informationOutdoor Reset IQ Option Card, p/n
Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...
More information- User Brochure Programmable Thermostat 510
- User Brochure Programmable Thermostat 510 U 510 09/09 Congratulations on the purchase of your tekmar programmable thermostat. This thermostat combines easy-to-use programming with advanced features to
More informationApplication Guide. Vitodens 100-W B1HA/B1KA Residential Boiler
Application Guide Vitodens 100-W B1HA/B1KA Residential Boiler APPLICATION GUIDE The application examples contained in this document serve as a guideline only. These are not engineered drawings and are
More informationHPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations
Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control
More informationAQ475A Aquatrol Outdoor Temperature Compensator for Boilers
A Aquatrol Temperature Compensator for s Features PRODUCT DATA Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature. Selectable Warm Weather
More informationprestige Control Application Supplement - Type 5 MCBA WARNING
prestige Control Application Supplement - Type 5 MCBA L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all
More informationHydronic Mechanical Panels
Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc.
More informationBHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions!
BHSAPPMAN 08/00 USA Applications Manual Ecomatic / Logamatic Controls Save These Instructions! TABLE OF CONTENTS 1 2 3 4 5 6 7 8 Introduction 1 Terms 2-4 Description of Wiring Terminals 5-7 Application
More informationhydronics WHAT S WRONG WITH THIS SCHEMATIC?
BY JOHN SIEGENTHALER WHAT S WRONG WITH THIS SCHEMATIC? In the September/October 2005 issue of HPAC Magazine, methods to draw hydronic piping schematics were discussed. These drawings are an efficient way
More informationheat interface units A BOILER WITHOUT A FLAME
A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.
More informationOutdoor Reset IQ Option Card, p/n
Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...
More informationA. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.
SECTION 23 09 93 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1 WORK INCLUDES A. Base Bid: Heating Contractor provide: Control sequences for HVAC systems, subsystems, and equipment. B. Alternate
More informationProduct Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen
Hydronic Mixing Block Version 1.104 The Hydronic Mixing Block is a mixing device and boiler control, with a built in circulator and system controller. The block can provide either a fixed or reset water
More informationInstallation & Operation Manual
Snow Melting Control 654 Installation & Operation Manual 654_D 06/13 Snow Melting Replaces: New Introduction The Snow Melting Control 654 is designed to operate electric or hydronic equipment to melt snow
More informationMulti Boiler Guide. Kit #
Multi Boiler Guide Kit # 550002186 Technical Support @ 800-325-5479 Phone: (315) 797-1310 Fax: (866) 432-7329 e-mail: info@ecrinternational.com web site: www.ecrinternational.com Information and specifications
More informationCommercial Noritz Water Heater Multi-System Application Sheet
Commercial Noritz water heaters can be used individually or in a Multi-System (2+ units) when used with either a Quick Connect Cord or a multi-unit. QC-1 (Quick Connect Cord) SC-1-6M SC-1-12M SC-1-24M
More informationInstallation & Operation Manual
519_D Radiant Thermostat 519 03/13 Zoning Replaces: New Installation & Operation Manual Introduction The Radiant Thermostat 519 accurately controls the room and/or floor temperature for a hydronic heating
More informationOutdoor Reset Control Theory FULL versus PARTIAL reset
Outdoor Reset Control Theory FULL versus PARTIAL reset Conventional boilers must be protected against sustained operation at low temperatures. If not, they will be damaged by sustained flue gas condensation.
More informationService Manual Models:
100267829_2000508773_Rev B Service Manual Models: 55-285 WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this manual and the
More informationApplications and Piping Strategies for Condensing Boilers - Introduction
Applications and Piping Strategies for Condensing Boilers - Introduction Foil 2, 10/2015 Viessmann Manufacturing Applications and Piping Strategies for Condensing Boilers Webinar Objectives: 1. Control
More informationVerasys System Operation Overview Technical Bulletin
Contents subject to change. Verasys System Operation Overview Technical Bulletin Code No. LIT-12012370 Issued January 2016 Refer to the QuickLIT Web site for the most up-to-date version of this document.
More informationSolar Thermal Planning Worksheet Date: / /
Solar Thermal Planning Worksheet Date: / / Preliminary Report By: Project Name Address Installation Location or City State Contractor or Agent: Address: Telephone / Fax: Email: Project: New Construction
More informationService Manual Models: Series 100 & 101
100305279_2000558130 Rev A Service Manual Models: 55-285 Series 100 & 101 WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this
More informationprestige Control Application Supplement - Type 5 MCBA WARNING
prestige Control Application Supplement - Type 5 MCBA WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More informationHEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q
SIGNAL REPEATER RC2100 WI-CON Wireless Heating Control for Steam and Hot Water Boilers No sensor wiring required Intelligent sensing algorithm saves energy Low limit control and alarm alert operator of
More informationSUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK
This booklet will assist you in piping, wiring and setting the controls of the Riva Advance SV boiler to control an indirect fired hot water tank. All pipe tails for the connection to the tank are supplied
More informationprestige Control Application Supplement WARNING
prestige Control Application Supplement WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions within this
More informationInstruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator
Instruction Sheet Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator The Variable Speed - Outdoor Reset 00 Cartridge Circulator (00-VR) is a microprocessor-based pump designed to regulate the
More informationHPS Controls Ltd. Series 100 LTV / CTV Zone Control Stations. Heating and Radiant Floor Zone Control Stations. Installation Instructions
Series 100 LTV / CTV Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control Stations. We
More informationVariable Speed Outdoor Reset 00 Circulator (00-VR)
Taco Radiant ade Easy Application Guide Variable Speed Reset 00 Circulator () EFFECTIVE: arch, 2004 Products & Applications PA03 SUPERSEDES: New OVERVIEW Variable Speed Reset 00 Circulator () The is a
More informationAqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND
Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating
More informationRVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning
G2524en Heating controller Installation Instructions RVL471 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a
More informationG a
G2474 74 319 0081 0 a en Installation Instructions Heating controllers RVP3... Installation Place of installation In a dry room, e.g. in the boiler room Mounting choices: Control cabinet (in the front,
More informationIBC Technologies Venables Street, Vancouver, BC, V5L 2G8 - Ph Fax E -
TECHNICA NOTES October 2010 MUTIPE BOIER SYSTEMS Version 2.0 Technologies - 1543 Venables Street, Vancouver, BC, V5 2G8 - www.ibcboiler.com Ph - 604 877 0277 Fax - 604 877 0295 E - info@ibcboiler.com IMPORTANT:
More information- Data Brochure Snow Detector & Melting Control 667
- Data Brochure Snow Detector & Melting Control 667 D 667 09/02 The Snow Detector & Melting Control 667 is a microprocessor-based control which operates a snow melting system. The control can operate automatically
More informationService Manual Models:
KBXII-SER Rev A Models: 400-801 WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this manual and the Knight XL Installation
More informationCirculators high efficiency ECM Circulators
Circulators high efficiency ECM Circulators Circulators high efficiency ECM Circulators Small ECM circulators now available in North America Grundfos Alpha: Provides constant and proportional differential
More informationHWE-SS DIGI-El i t e Hydronic Single-Stage Boiler Control
R INSTALLATION AND OPERATION INSTRUCTIONS HWE-SS DIGI-El i t e Hydronic Single-Stage Control Hot Water Control with Outdoor Reset, Set Point, and DHW for Hydronic Heating Applications 2 Line Alphanumeric
More information