CENTRAL BOARD OF SECONDARY EDUCATION SHIKSHA KENDRA, 2, COMMUNITY CENTRE, PREET VIHAR, DELHI

Similar documents
BOQ FOR FIRE HYDRANT & FIRE ALARM SYSTEM AT T.I.E

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) PRICED BILL OF QUANTITIES

CENTRAL BOARD OF SECONDARY EDUCATION, 2, COMMUNITY CENTRE, PREET VIHAR, DELHI-92

CENTRAL BOARD OF SECONDARY EDUCATION, 2, COMMUNITY CENTRE, PREET VIHAR, DELHI-92 TENDER NOTICE

TENDER DOCUMENT FOR CHECKING, TESTING AND REPAIRING OF FIRE HYDRANT AND SPRINKLER SYSTEM AT Bank Of India, STC Building, B-32, Sector-62 Noida

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder

TENDER NOTICE. Kolhapur Zilla Sahakari Dudh Utpadak Sangh Ltd. B-1, M.I.D.C., Gokul Shirgaon, Tal. Karveer, Dist. Kolhapur

Purchase: (Fire Fighting) May 26, Sub: Quotation for AMC of Fire Fighting Systems

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI

VOLUME 2 (BOQ & Price Bid)

EE/ / To, Dear Sir,

INDUSTRIAL EXTENSION BUREAU

Department of Biochemistry University of Lucknow Lucknow

Tender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE

NATIONAL BANKING GROUP WEST-1

Date of Start and downloading the tender 12 sep 2018

SUPREME COURT OF INDIA ADMN. MATERIAL BRANCH NOTICE INVITING TENDER FOR COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT FOR RE-FILLING OF FIRE EXTINGUISHERS

The following are the terms and conditions for the firms for submission of bids:

STAR HOUSE BANK OF INDIA NATIONAL BANKING GROUP NORTH-I H-2 CONNAUGHT CIRCUS Middle/Outer Circle, Phone No

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD., CIRCLE OFFICE, BHOPAL PART B : PRICE BID

MANUFACTURER OF LT PANELS

1 NOS. 25mm x 4 mm thick with PVC sleeving e) 1Set, RYB, indicating lamps & CT

Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No.

TENDER No /NIT NO. BECIL/FF/2014/55 RECTIFICATION / MODIFICATION OF EXISTING FIRE FIGHTING & FIRE ALARM SYSTEM WORKS

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

LIFE INSURANCE CORPORATION OF INDIA DIVISIONAL OFFICE 16/275, CIVIL LINES, KANPUR

DC POWER DISTRIBUTION BOARD

BANK OF BARODA BIHAR REGIONAL OFFICE, 4 TH FLOOR, ANAND VIHAR, West Boring Canal Road, Patna TENDER NOTICE

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD.

DATASHEET HIGH VOLUME LONG RANGE FOAM MONITOR GPM

BHARAT HEAVY ELECTRICALS LIMITED RAMACHANDRAPURAM :: HYDERABAD 32 TOWNSHIP ADMINISTRATION

* To be remitted only through DD/Banker Cheque, in favour of Bank of Baroda, payable at Bhopal.

Item/clause/Page no. Description as per tender. To be read as

BANK OF BARODA BARODA CORPORATE CENTRE MUMBAI

NOTICE INVITING TENDER

SECTION STEAM CONDENSATE PUMPS

Roto-Jet I & II Tube Cleaning Systems

Ravi Malik General Manager

TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS

TOTAL OF GROUP A ESTIMATE PROPOSED AIR CONDITIONING WORKS FOR STATE BANK OF IND. SR. Description QTY UNIT GROUP A AIRCONDITIONING

TENDER FOR EMPANELMENT OF VENDORS FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES IN ZONE UNDER

Pressurisation units & expansion vessels

BANK OF BARODA ZONAL OFFICE, MP & CG ZONE BHOPAL TENDER NOTICE

TENDER NOTICE FOR RATE CONTRACT FOR SUPPLY, INSTALLATION AND REFILLING OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS

INSTALLATION, OPERATION & MAINTENANCE MANUAL

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

SECTION FIRE PUMP AND CONTROLS

TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN KARNATAKA & ANDHRA PRADESH ZONE

Servicing, refilling & maintenance of Fire Extinguishers for RBPH W - 36

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

TENDER FOR EMPANELMENT OF VENDORS

Tender Enquiry No: BCL/PUR/MNG-PD/Fire Extinguisher/CW/18 Dated: Due date : M/s

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

TR CASSETTE AC 1 NOS TR CASSETTE AC 1 NOS. Rate in words : TR HIGH WALL (3 star rated) 2 NOS.

BILL OF QUANTITY OF AIR CONDITIONING WORK FOR SBI JASDAN BRANCH, RAJKOT

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

TENDER DOCUMENT FOR NON-COMPREHENSIVE AMC OF FIRE DETECTION, FIRE HYDRANT & SPRINKLER,

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

PART-A, ANNUAL MAINTENANCE CONTRACT FOR PLANT 1 PACKAGE AIR CONDITIONER UNITS. SOR No Description of Services Qty UOM

Residential Fire Fighting Booster Systems

OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.)494005

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

TENDER NOTICE FOR DESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING AND MAINTENANCE OF FIRE ALARM SYSTEM AT APROX.

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES

Technical Specification

ECONOBOOST EB II & EB III Compact Water Booster

NIT NO. BSRDCL-2039/ TENDER DOCUMENT INSTALLATION, CONFIGURATION, TESTING, COMMISSIONING AND TRAINING OF SMOKE DETECTION FIRE ALARM SYSTEM

Direct Fired Heater Model AD Specification

DISASTER MANAGEMENT PLAN 3.0 IDENTIFICATION OF MAJOR HAZARD POTENTIAL

COLLEGE OF AGRICULTURE, NAGPUR

B. Section Transfer Switches: Automatic transfer switch.

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

Condensate Boiler Feed Water Make-Up

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Casey Craft

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

TENDER NOTICE FOR DESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING AND MAINTENANCE OF FIRE ALARM SYSTEM AT APROX.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

Global-Tek (Singapore) Pte Ltd

RA 701 B Batterie assembling. As at: 01/15/10 Time:21:19

SPECIALITY HOSES EXCELLENCE PRODUCT CATALOGUE

ODISHA POWER TRANSMISSION CORPORATION LIMITED OFFICE OF THE GENERAL MANAGER EHT (O&M) CIRCLE, BIDYUTPURI COLONY, BERHAMPUR

TENDER DOCUMENT FOR RATE CONTRACT FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES

TENDER NO. PGVCL/PROC/SMC BOX FOR CT OPERATED METER & Junction Box/867

Mission Critical. Fuel Supply Systems

Parts and Service Manual

MK-1080 PAVER SAW OWNER S MANUAL & PARTS MANUAL

Design and Supply of Fire Equipments. External Fire Fighting Systems.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Calling for Quotations

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

INVITATION FOR QUOTATION. TEQIP-II/2015/RJ1G08/Shopping/25

Transcription:

CENTRAL BOARD OF SECONDARY EDUCATION SHIKSHA KENDRA, 2, COMMUNITY CENTRE, PREET VIHAR, DELHI 110092 NOTICE INVITING TENDER CBSE invites sealed Item rate tender from eligible contractors who are registered with CPWD,MES, NDMC, DDA, and other Govt. Dept., PSU, autonomous Bodies for the under mentioned work. The Contractor should have executed minimum two works costing Rs. 9.00 Lacs each or three works costing Rs. 6.00 Lacs each during last three years. Name of the Work Repairs to Fire Protection System in CBSE Head Qtr. Building Preet Vihar. Estimated Cost Period of Completion Earnest Money Deposit (EMD) Non-refundable cost of Tender document Last date & time of submission of tender Date & Time of Opening of technical Tender Validity of offer 1594800(Rupees Fifeteen Lakh Ninety Four thousand Eight hundred Only) 60 Days Rs. 39500/- (Rs. Thirty Nine Thousand Five Hundred only) payable in F/O Secretary CBSE Delhi. Rs. 500.00 (Rs. Five Hundred only) in of DD/PO in favour of Secretary, CBSE payable at Delhi. Up to 12.01.2015 by 3:00 PM 12.01.2015 at 03:30 PM 60 days from the date of opening of price tender. *The Estimated cost is based on market rates. Tenders duly completed shall be received in the tender-box placed at Reception Counter, CBSE, HQ, Shiksha Kendra, 2, Community Centre, Preet Vihar, Delhi 110092, up to 3.00 PM on dt. 12.01.2015. The detailed tender documents can also be seen and/or downloaded from the web site http://www.cbse.nic.in. Joint Secretary (A & L)

Name of work: Repairs to Fire Protection System in CBSE Head Qtr. Building Preet Vihar. S. No. Description Unit Qty. Rate Amount 1 Dismantling of old defective non functional Fire Nos. 1 Hydrant main Fire Control Panel with main incomer, bush bar, jockey panel 20H.P, 2 Nos. 100H.P starter etc complete. 2 Providing and fixing dust & vermin proof cubicle type, IP-52 rating, motor control centre fabricated from powder coated standard (Asian) 14 SWG, CRCA sheet. All equipments should be of L&T & Schneider make, including the cost of multistrand copper wire 6mm or as req. For earthing, connecting & comprising of size: (2070x1200x400) Incomer: One incoming main isolation TPN MCCB of 630A 25KA Thermal Magnetic base Release One fully taped Al.bus bar of 600A capacity in separate bus bar chamber. One square panel type Voltmeter reading 0-500 V with rotary selector switch for reading voltage between phases. One panel type Ampere meter (0-600/5A) with selector switch and CT 3 phase indication lights Outgoings 2 no. Star-Delta starter, 1 no. DOL Starter of suitable capacity. 3 No. single phase prevents of suitable rating one for each motor Set 1 2 Nos.MNX 110 A TP Contractor. 1-nos. 30-50 amp over load relay, 100A TPN MCCB 10 KA thermal Megnetic base Release for Jockey pump (20 H.P) 2 nos. rotary type auto/manual off selector switch Colour coded internal wiring from main to bus bar, switchgear, starters, indicating lamps complete in all respect. 3 Supply, installation, connecting, testing and commissioning of expandable up to 20 fully monitored Zone microcontroller based fire Alarm control panel, work on RS-485 communication protocol protection against short circuit & over load condition. 356-event history with time & date. On site programming of Zone. 40x2 characters LCD Display. Battery back up (2x12,7) ah) with in built battery charger. set 1

4 Dismantling of old defective non functional Main set 1 Fire Alarm Control Panel including dismantling of wiring connection and making proper marking on each floor wiring. 5 Over Hauling of Diesel Engine 60 BHP-R1040, By Set. 1 opening top piston, Cleaning of nozzle, replacement of oil & air filter, Repairing of fuel pump, Cleaning of all piston & chamber. Complete in all respect. 6 Repairing & Reconditioning of DSM pump attached with engine, Replacement of foiling part. Set. 1 a) 2 nos. Bearing, ss shaft, 2 nos mechanical seal, and ss shaft complete in all respect. 7 Supply & Erection of M.S pipe 100 dia for Mtr. 6 extension of D.G cylincer. 8 Supply Fixing of pressure Gauge 0-10 Kg/cm 2 Nos. 6 9 Supply fixing of 25 mm dia air release valve Nos. 3 10 Supply fixing of pressure switches 0-10 kg/cm 2 Nos. 3 (Danfoss) with cock. 11 Supply fixing of 150 mm dia. Butter fly valve with Nos. 5 Flage, Gasket, Nut Bolt, Welding, Cutting etc. 12 Supply & installation of following sizes of C (Heavy) Pipes conforming to IS 3589 & IS:1239 parti &II along with all accessories like all fittings (standard MS fitting with welded joint shall be used on the pipes) tees, elbows, reduce, unioun, flages, rebber gaskets, GI nuts bolts, washers. MS C heavy Class Pipe a. 150mm dia b. 150mm dia c. 150mm dia d. 150mm dia e. 150mm dia 13 Supply & Installation of 63 mm dia instantaneous pattern SS metal branch short pipe, 20 mm di nozzle confirming to IS 903, suitable for inter connection to hose pipe coupling complete as required. 14 Supply & Installation Lockable cabinet of size not less than 0.75x0.6x0.25 mtr made out of Fiber sheet having central opening and 4 mm thick glazed glass doors suitably marked on the outside with th letters FIRE HOSE including necessary locking arrangement and shall be painted with one coat of primer and two coats of synthetic enamel paint of approved shade. 15 Supply & installation of rubber Reinforced Lined fire hose Type A (as per IS:636) of 63 mm dia and length as described below. The hose shall be Nos. 8 Nos. 4 350 60 18 12 18

rated for burst pressure of 35.7 kg/sqcm. Hose shall be complete with SS metal male &female couping bound & riveted to hose pipe with copper/ss rivets & 1.5 mm copper/ss wire. 15 m length Nos. 12 16 Dismantling & Re-erection of Hydrant Valve & 4- Nos. 6 way on new Erected Line. 17 Providing and applying one coat of 4mm thick PYPKOTE or COATEK anti rust pipe protection including approved primer as per manufactures specifications and lap of 25 mm to make an impermeable layer on MS pipes in trenches or on structural/masonary members complete members complete including surface preparation. a. 150 mm dia Mtrs. 30 18 Supplying, installing, testing and commissioning of following electric motor driven pumping sets for fire fighting purposes including, making piping and electrical connections and suitable for automatic operation. The pump set shall consist of/complete with: 1) Horizontally mounted single end suction type pump of cast iron body and having bronz impellors 2) Squirrel cage TEFC induction motor suitable for 415V 3 phase 50 Hz AC supply of Requires HP rating suitable for the specified duty of pump with synchronous speed of 2900RPM 3) Jockey Pump 180 LPM against 70m 19 Dismantling of old rusted non functional sprinklers pump & 50 H.P motors including suction & discharge piping, NRV & Sluie Valve 20 Dismantling of old rusted non functional Hydrant System suction & discharge piping, NRV & Sluie Valve etc and Re-installation as per proper Design of negative suction pumping arrangement making function 2-nos. Hydrant pump with 100H.P motors. 21 Excavation of soil/road for laying of pipe of size 150/100/80mm dia under Ground and Back filling the same. 1 No. 1 Lot. 1 Lot. 20 R.M

Terms and Conditions 1. The work should be executed as per CPWD specification and as per best industrial practice. 2. The work should be completed in 45 days. 3. Electrical panels should be as per CPRI approved standards. 4. Quantities may vary upto 25% and additional items if required would be carried out after approval of the Engineer incharge. 5. 5% of total value of the bill would be retained as security against defect liability and released after six months. 6. Only final bill would be paid within 30 days of submission of bill after successful completion of the work. 7. The work should be carried out preferably on holidays so that working of office is not disrupted. 8. All the material would be got approved by Engineer in charge before installation. 9. In case of dispute, decision of chairman CBSE should be final and binding. 10. Agency would execute an agreement for execution of work. (Signature of the Agency) With complete address and seal Add. Tel. No.: Mobile No.: