PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES
|
|
- Louise Bradley
- 6 years ago
- Views:
Transcription
1 PORTABLE HYDRANT PN1 1A; 2A; 1B; 2B; 1C; 2C TYPES HP 1 page 1A (type 1) (type 2) In water supply systems for fire extinguishing or other necessities. - Design... in conformity with STAS 698; - Nominal pressure bar; - Working temperature range tmax / Tmin : 4 C / 4 C; - Execution : - type 1 - with simple elbow; - type 2 - with double elbow; - Size of connecting piece: - A, B or C, STAS Double elbow, single elbow, tube body, connecting nut with ears, sealing flange, fixed connector, bonnet... aluminium alloy; - Gasket... rubber. HYDRANT TYPE 1A 2A 1B 2B 1C 2C d1 d2 d3 d4 L1 h1 Net weight 192 Rd Rd
2 UNDERGROUND HYDRANT PN 1 DN 65; 1 HSX-1 page 2 A Used as fire extinguishing equipment, may be connected to drinking water or industrial water systems PN 1 as follows: - connecting flanges DN PN1 ISO 75-2; DIN 251; BS EN 192-2; - to PEHD pipe with socket and locking sleeve; - connecting flanges DN DIN 2864 PN1 for ductile iron pipes. It has been designed in order to operate in difficult working media, industrial areas, seaside or with hot climate. The underground hydrant HSX is manufactured in conformity with STAS 695 issued in cooperation with Firemen s Committee. Allows the connection of portable hydrant STAS 698 or the connection of portable hydrant with valves STAS 697. The hydrant is has been designed to carry out the following functions: - shutting-off - opening by operating hydrant stem with a special driving key (STAS 696), the operating stress being low; - at opening, the draining system shall be completely obturated, internal parts design assuring a minimum head loss, and at shutting-off the draining system shall be opened in order to allow water removal from the hydrant; - complete hydrant disassembling and spare parts replacement may be easily performed; - freezing protection hydrant internal part, being above the main seat, shall be released of the water remained after operation. The bore located at the lower part assures an inside draining within max. 1 minutes. Waste water volume remained into the hydrant after complete draining is not exceeding 5 cm³; - disc gasket may be replaced without hydrant digging out. COMPONENTS: 1. Protection box - in conformity with STAS 3226; 2. Hydrant - in conformity with STAS 695; 3. Foot elbow: - flanged (standard execution); - with flange and locking sleeve (execution on order); - with flange and sleeve - in conformity with STAS 1875 (execution on order). MATERIALS OF MAIN PARTS: - obturator box, obturator body, bonnet, body, nut support, driving head: - cast iron EN GJL 25 SR EN 1561; GG25 DIN 1691; - body of jaw connection: - ductile iron EN GJS 5-7 SR EN 1563; GGG5 DIN 1693; - stem nut, seating ring, disc seat: - copper alloy; - stem, connecting pipe: min. 11,5% Cr stainless steel; 41 S21 BS 156; X2Cr13 DIN 1744; - obturator, gaskets: - EPDM rubber STAS 7278; - bolting: - stainless steel A2-7. PROTECTION AGAINST CORROSION: All internal surfaces, except for: rubber, stainless steel or bronze surfaces, also external surfaces of underground part are coated with epoxy powder paint 25µm thick, GSK quality, standard colour RAL 39. Protection box is coated with zinc primer and black resin epoxy paint. DATA TO BE SUBMITTED WITH THE ORDER: User shall specify: execution variant, nominal diameter, burying depth, type of connecting flange. DN 65 1 Overall dimensions DE DN of system connecting flange System connecting dimensions H1 H d1 d2 nxd3 Jaw connection d4 d5 Hydrant Connection with locking sleeve Net weight Protection box Foot elbow ξ Head loss factor x * * x pipe For confirmation, please use the technical sheet of agreement (FTC 19)
3 SURFACE HYDRANT PN 1 HSf-1 page 3 A - in water supply systems for fire extinguishing or for other needs. - design..... in conformity with STAS 3479; - nominal pressure bar; - working temperature range. Tmax/Tmin: 4 C / 4 C; - operation.... manual; - seat... rubber / metal; - dimensions of connecting flanges... PN1 ISO 75-2; BS EN 192-2; DIN body, bonnet, obturator body, driving bonnet - cast iron EN GJL 25 SR EN 1561; GG25 DIN 1691; - ductile iron EN GJS 5-7 SR EN 1563, GGG5 DIN 1693, on special request; - body seat ring : copper alloy; - obturator gasket: rubber; - A, B, C type connectors : aluminium; PROTECTION AGAINST CORROSION: All internal surfaces, except for: rubber, stainless steel or bronze surfaces, also external surfaces of underground part are coated with epoxy powder paint 25µm thick, GSK quality, standard colour RAL 39. The above-ground part is externally coated with RAL 32 red. DESIGNATION: - Surface hydrant DN x H1; - DN - nominal diameter [mm]; - H1 - burying depth [m]. DN H H1 H2 d1 d2 nxd3 Net weight Connectors ~ kg Dimensions Foot Quantity Type Hydrant (inch) elbow C 2" A 4" 19 8x B 2 1/2" A 4" 25 For confirmation, please use the technical sheet of agreement. (FTC 2)
4 SURFACE HYDRANT FOCUS TYPE PN 16 FOCUS page 4 A Used as fire extinguishing equipment, may be connected to drinking water or industrial water systems PN 16 as follows: - connecting flanges DN 8 1 PN16 ISO 75-2; DIN 251; BS EN 192-2; - to PEHD pipe with socket and locking sleeve; - connecting flanges DN 8 1 DIN 2865 PN16 for ductile iron pipes. Designed in 3 modules, FOCUS hydrant ensures besides a modern design a performance at the level of the highest European exigencies in matters of fire extinguishing equipment and valves. FOCUS was designed for operation in difficult medium conditions, industrial areas, and seaside or cold climate. Internal and external coating system with epoxy powder meeting GSK norm requirements, also all bolting manufactured in stainless steel A2-7, assure a long lifetime. FOCUS meets the requirements of DIN 3222 and STAS 3479, carrying out the following functions: - safe tightness at two levels: disc and spherical obturator. EPDM parts, also the design system are not affected by possible deposits or sediments. - Shutting-off opening, by operating hydrant stem with a special driving key, the operating stress being low. - Protection against eruption the above-ground part is able to support accidental lateral impacts without affecting tightness. Hydrant repaire shall consist only in bolts and half-flanges replacement - At opening, the draining system shall be completely obturated, internal parts design assuring a minimum head loss. - Freezing protection hydrant internal part, being above the main seat, shall be released of the water remained after operation. The bore located at the lower part assures an inside draining within max. 15 minutes. Waste water volume remained within the hydrant after complete draining is not exceeding 8cm³. - Easy connection through the two, respectively, the three specific connectors, protected with covers safe against theft. - Burying depth: 1.25 m or 1.5 m, depending on requests. - Possibilities of angular orientation of the upper body. - Connection to different pipe types: steel, PEHD and ductile iron. MANUFACTURER TESTS: - shell and compactity: 24 bar; - seat 17.6 bar. Tests are 1% performed on each product in a lot. PROTECTION AGAINST CORROSION: All internal surfaces, except for: rubber, stainless steel or bronze surfaces, also external surfaces of underground part are coated with epoxy powder paint 25µm thick, GSK quality, standard colour RAL 39. The above-ground part is externally coated with RAL 32 red.
5 SURFACE HYDRANT FOCUS TYPE PN 16 FOCUS page 5 A - nominal pressure bari; - working temperature range... Tmax/Tmin : 4 C / 4 C; - seat rubber / metal; - burying depth: m and 1.5 m; - operation.... manual, with special key; - Possibility of angular orientation of the upper body; - Protection against eruption; FOCUS was designed to meet DIN 3222 and STAS 3479 standard requirements. MATERIALS OF MAIN PARTS: - obturator body, lower body, protection half-flange, bonnet: - cast iron EN GJL 25 SR EN 1561; GG25 DIN 1691; - upper body: - ductile iron EN GJS 5-7 SR EN 1563; GGG5 DIN 1693 on special request; - disc: - ductile iron EN GJS 5-7 SR EN / EPDM rubber; - nut 1: - cast iron / EPDM rubber; - obturator: - ATCu8 / EPDM rubber; - driving bonnet: - ductile iron EN GJS 5-7 SR EN 1563, GGG5 DIN 1693; - stem: - min. 11,5% Cr stainless steel; 41 S21 BS 156; X2Cr13 DIN 1744 / copper alloy; - connectors A, B type : - aluminium; - bolting: - stainless steel A2-7. H1 burying depth DATA TO BE SUBMITTED WITH THE ORDER: User shall specify: execution variant, nominal diameter, burying depth, type of connecting flange. Net DN DE H H1 h1 h2 d1 d2 nxd3 Connector weight xB x xB + 1xA Connection with locking sleeve Connectors DN Pieces Type Dimensions 8 2 B 2 1/2" 1 2 B 2 1/2" 1 A 4" pipe
6 SURFACE HYDRANT PN 16 HSR-16 page 6 A - in water supply systems for fire extinguishing or for other needs. - nominal pressure bar; - working temperature range... Tmax/Tmin : 4 C / 4 C; - operation..... manual; - seat.... rubber / metal; - dimensions of connecting flanges.. PN16 ISO 75-2; BS EN 192-2; DIN body, bonnet, disc body, driving bonnet - cast iron EN GJL 25 SR EN 1561; GG25 DIN 1691; - ductile iron EN GJS 5-7 SR EN 1563; GGG5 DIN 1693, on special request; - body seat ring.... copper alloy; - disc gasket... rubber; - stem min. 11,5% Cr stainless steel; 41 S21 BS 156; X2Cr13 DIN 1744; - connectors A, B, C type... aluminium; PROTECTION AGAINST CORROSION: All internal surfaces, except for: rubber, stainless steel or bronze surfaces, also external surfaces of underground part are coated with epoxy powder paint 25µm thick, GSK quality, standard colour RAL 39. The above-ground part is externally coated with RAL 32 red. DESIGNATION: - Surface hydrant DN x H1; - DN - nominal diameter [mm]; - H1 - burying depth [m]. DN L L1 L2 H H1 H2 H3 H4 H5 d1 d2 nxd3 Net weight Connectors Quantity Type Dimensions foot hydrant (inch) elbow x18 1 A 4" 2 B 2 1/2" x22 2 A 4" 2 B 2 1/2" For confirmation, please use the technical sheet of agreement. (FTC 2)
7 SIGNALING AND CONTROL DEVICE FOR AUTOMATIC FIRE EXTINGUISHING PLANTS OF SPRINKLERS TYPE, WATER-WATER SYSTEM PN 1 DN 15 ISIA-1 page 7 A The automatic plants for fire extinguishing water-water system are so designed that, without man intervention, can both detect fire beginning and extinguish it with damages at the smallest level. WORKING AND DESIGN CHARACTERISTICS: - nominal pressure bar; - working pressure range bar; - working fluid drinking or industrial water with max. slurry 1 mg/dm3 and ph ; - working temperature range... Tmax/Tmin : 4 C / 4 C; - electric switch box supply voltage V ; 5 Hz; - mounting position..... vertical; - electric switch box protection degree... IP 32; - connecting flanges..... PN 1 ISO 75-2; BS EN 192-2; DIN 251; - net weight ~ 394 kg.
8 SIGNALING AND CONTROL DEVICE FOR AUTOMATIC FIRE EXTINGUISHING PLANTS OF SPRINKLERS TYPE, WATER-AIR SYSTEM PN 1 DN 15 ISIAE-1 page 8 A water inlet The automatic plants for fire extinguishing water-air system are so designed that, without man intervention, can both detect fire beginning and extinguish it with damages at the smallest level. WORKING AND DESIGN CHARACTERISTICS: - nominal pressure bar; - working pressure range bar; - working pressure range in the sprinklers system bari - working fluid drinking or industrial water with max. slurry 1 mg/dm3; - working temperature range... Tmax/Tmin : 4 C / 4 C; - electric switch box supply voltage V ; 5 Hz; - mounting position.....vertical; - electric switch box protection degree...ip 32; - connecting flanges.....pn 1 ISO 75-2; BS EN 192-2; DIN 251; - net weight ~ 45 kg.
9 SOLENOID VALVE PN 1 DN 15 VE-1 page 9 A The PN 1 solenoid valve is used in fire extinguishing plants on the main water supplying pipe. WORKING AND DESIGN CHARACTERISTICS: - working pressure... 1 bar; - nominal diameter mm; - working temperature range Tmax/Tmin: 4 C / 4 C; - working fluid... water; - flow direction unique; - seat... rubber / metal; - connecting flange... PN1 ISO 75-2; BS EN 192-2; DIN 251; - operation... electric, electromagnet 22 V c.a. ; 24 V c.c. ; P = 1,55 kw; protection degree IP 44; - opening time... max. 4 sec. - maintaining in open position... max. 3 min. - pause time... 3 hours; - mounting position... on horizontal pipes with electromagnet up; - net weight... ~122 kg. - body, disc, closing flange - cast iron EN GJL 25 SR EN 1561; GG25 DIN 1691; - disc seat - copper alloy; - adjusting stem, driving stem, seat - min. 13% Cr stainless steel; 41 S21 BS 156; X2Cr13 DIN 1744; - disc gasket - rubber.
10 AEROMECHANICAL FOAM GENERATOR FOR TANKS WITH FIXED BONNET GSCF page 1 A - in fix fire extinguishing plants at the tanks for petroleum products and inflammable liquids, plants using as extinguishing agent a mixture of air, water and foamy liquid (aeromechanical foam). - working presure range bar; - solution flow ; 8; 16 l/min; - foam ratio in water %. - body, bonnet, suction chamber, flanges OL carbon steel St 37-3 DIN 171. Solution Net flow Size d1 d2 nxd3 d4 d5 d6 nxd7 A B C D E F G weight at 5 bar [l/min] GSA4CF x x GSA8CF x x18 17 GSA16CF x
11 AEROMECHANICAL FOAM GENERATOR FOR TANKS WITH FLOATING BONNET GSCP page 11 A - in fix fire extinguishing plants at the tanks for petroleum products and inflammable liquids, plants using as extinguishing agent a mixture of air, water and foamy liquid (aeromechanical foam). - working pressure range bar; - solution flow , 4 l/min; - expansion degree ; - foam ratio in water %. - body, flanges... OL carbon steel St 37-3 DIN 171. Size Net Solution flow at 5 bar A B weight [l/min] GSA 2 CP GSA 4 CP
12 AUTOMATIC WATER DOSIMETER WITH VARIABLE FLOW DAS-16 page 12 A water inlet The automatic water dosimeter with variable flow is used in fire extinguishing systems at petroleum and inflammable product plants using as extinguishing agent a mixture of water and foamy liquid (aeromechanical foam). - min. water flow , 12, 16 l/min; - max. water flow , 12, 16 l/min; - foam ratio in water %; - water max. working pressure bar; - foam working pressure water pressure + 1 bar; - flanges nominal pressure bar. - sections : - carbon steel; - case : - cast steel; - gasket : - rubber, klingerite; - sleeve : - NBR rubber. Net Size D d1 d2 nxd3 D2 D4 nxd5 weight DSA DSA x18 12x DSA
13 DISCHARGE VALVE FOR TANK WAGONS RVC page 13 A DESIGN CHARACTERISTICS: - nominal diameter: DN 1 - maximum working pressure: 4 bar - maximum flow speed through the valve: 2.5 m/s - connecting flanges: PN1 SR-ISO 75/ raised and notched sealing surfaces: PN1 STAS working fluid: -white or black petroleum products, fuel, aircraft fuel, fuel for reaction aircrafts, kerosen, white-spirit, etc. - branch flange shall be delivered on customer request, fitted with 8 nuts M16 gr.8 STAS and 8 Grower washers SR 7666/2-N16. - body, disc: - ductile iron 4-18-L SR ISO 183 GGG - disc gasket: - rubber - VITON type - bonnet gasket: - rubber - VITON type - NBR type. - shaft: - min. 11,5% Cr stainless steel. SEATS: - body/disc: - gasket - VITON type; - body/bonnet: - gasket - VITON type (STANDARD execution) - NBR type - shaft/body: - virgin PTFE bushing WORKING TEMPERATURE: Tmax/Tmin : 6 C / -2 C; WORKING AND TEST PARAMETERS: - shell: - at 6 bar - seat: - at hydraulic pressure 4.5 bar - at pneumatic pressure 4.5 bar Allowed leakage in conformity with ISO 528 grade A. MOUNTING: - flow direction: - unique, marked with arrow - mounting position: - horizontal. For confirmation, please use the technical sheet of agreement. (FTC 3 )
14 PROTECTION BOXES FOR UNDERGROUND HYDRANTS CP page 14 A A B E F B K H L C D G N The protection boxes shall be mounted along with the underground hydrant on PN 1 distribution networks for water supplying for fire extinguishing or other needs. DESIGN CHARACTERISTICS: - design and dimensions in conformity with DIN frame, bonnet : - cast iron EN GJL 25 SR EN 1561; GG 25 DIN 1691; - ductile iron EN GJS 5-7 SR EN 1563; GGG5 DIN1693 -on special request. COATING: - epoxy primer with zinc coated with tar-epoxy paint or black epoxy enamel; - without coating, on special request. Net DN A B C D E F G H K L N Weight (kg) Product approved by Romanian Firemen s Commitee
15 AIR RELEASE VALVE WITH SHUT-OFF VALVE PN16 RAD-VI-16 page 15 A Valves DN 5-2 shall be equipped with detachable flange - automatically performs air release during plants filling in with drinking and industrial water without impurities, pipe airing during plants emptying and releasing of air accumulation into pipes during service. - connecting flanges PN 16 ISO 75-2; BS EN 192-2; DIN 251; - the valve meets EN 174 requirements; DN Min. airing flow (m 3 /h) Min. disairing flow (m 3 /h) the valve has been freeze tested up to -3 C. -body, bonnet: - ductile iron EN GJS 5-7 SR EN 1563, GGG5 DIN 1693; -stem: - min. 11,5% Cr stainless steel - 41 S21 BS X2Cr13 DIN 1744; -disc: - cast iron EN GJL 25 SR ISO 1561; GG 25 DIN rubber; - carbon steel + rubber; -floating balls: - aluminium + rubber. SEATS: WORKING TEMPERATURE: Tmax/Tmin: 8 C / -1 C -body - disc: - ductile iron / rubber; -body - bonnets: -bonnets balls: - rubber O-rings; - rubber / copper alloy; - all rubber. MANUAFCTURER TESTS; TEST PRESSURE; LEAKAGE: - hydraulic tests in conformity ISO test pressure: - shell 1.5xPN - seat 1.1xPN - seat low pressure.3 bar - without leakage in conformity with ISO 528, grade A. NOTE: - The valve shall be mounted with the disc stem in vertical position and handwheel (driving head) in position up. - For other liquids, please do not hesitate to ask the manufacturer for confirmation. Connecting flanges DN D H H1 Lxl R For confirmation, please use the technical sheet of agreement. (FTC 18) d1 c d2 nxd3 b Net weight x x , , x x x x x x x 23*
CR20-07 A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR2-7 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos pump 965513 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/965513/cr-2-7-a-f-a-e-hqqe.html
More informationTechnical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved
Worldwide Contacts www.tyco-fire.com Model TJR Resilient-Seated Gate Valves Outside Screw and Yoke General Description TYCO Model TJR Resilient-Seated Gate Valves are used in Fire Protection Systems for
More informationUPZ PUMP POWER FOR TOP PERFORMANCE UNDER
Submersible borehole pump People at KSB we make your world flow round! UPZ PUMP POWER FOR TOP PERFORMANCE UNDER THE TOUGHEST CONDITIONS UPZ is top choice wherever submersible borehole pumps have to satisfy
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR32--2 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 9612212 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9612212/cr-32--2-a-f-a-e-hqqe.html
More informationNON-SLAM DYNAMIC ARV FAF 7330
PRODUCTION STANDARTS DN50 DN250 PN 10-16 Design EN 1074-4 End Connection EN 1092-2 / ISO 7005-2 Marking EN 19 Tests EN 12266 Corrosion Protection Industrial Epoxy Features y Non-Slam Dynamic ARV to be
More informationISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO
ISO9001:2008 Cert. 403 Certified FIRE HYDRANTS SFFECO since www.sffeco.com DRY BARREL FIRE HYDRANT Meets all applicable parts of ANSI/AWWA C502 standard UL Listed (EX16453) and FM Approved (FM1510) 250
More informationEssex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL
Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions
More informationVALVES SECTION 15100
VALVES SECTION 15100 PART 1 GENERAL 1.1 DESCRIPTION A. The requirements of this SECTION apply to all Work of this DIVISION where applicable. The valves, materials, and methods herein are generally common
More informationModel AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description
Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,
More informationAll All kin kin ds of Co t n r t ol V ol V v al es v Self-Actu Act a u ti a ng ng e Pr ss e ur ss e R egu e R
All kinds of Control Valves Self-Actuating Pressure Regulators Pneumatic Actuators, Desuperheaters Smart Valves Welcome to the Art of Control Valves Technology International West Technology Transfer Co.
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html
More informationCR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ
GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION pumps are Hi-Tech single stage, horizontal centrifugal pumps with magnetic driven coupling. In compact and silent close-coupled execution, they can be mounted on to B5 frame motors.
More informationInverted bucket steam traps Type OKZ PN6/PN16
-TERMOENERGETIKA- Inverted bucket steam traps Type OKZ PN6/PN16 We produce the inverted bucket steam traps type OKZ for nominal pressures PN 6 and PN 16 These traps have automatic air vent on the start-up.
More informationCR32-4 A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR32-4 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9612213 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612213/cr-32-4-a-f-a-e-hqqe.html
More informationCR64-1 A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html
More informationCR A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR64-2-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123528 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123528/cr-64-2-2-a-f-a-e-hqqe.html
More informationCR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR1-16 A-FJ-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651222 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651222/cr-1-16-a-fj-a-e-hqqe.html
More informationPhiloWilke Partnership Addendum No. 2 A/E Project No April 2016
SECTION 23 21 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.
More informationWet alarm valve stations
VdS Guidelines for water extinguishing systems VdS 2100-01en Requirements and test methods VdS 2100-01en : 2011-05 (02) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More informationFIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.
15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.
More informationSL S.S.N.51D
GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html
More informationHand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable
Hand pump JP-02 Hand pump JP-02 for acids, alkalies and water-based chemicals Shaft: Stainless steel 316 Ti Seals: Viton Flow rate: 0,3, 0,37 or 0,45 l/stroke* depending on lever position from 340 to 900
More informationEBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU
EBARA Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU water wastewater EBARA International Corporation Standard Pump Division S ubmersible Non-clog Pump Model DLFU DVFU DDLFU Features Watertight
More informationCR A-F-A-V-HQQV 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html
More informationHTM Circulation Pumps acc. to DIN EN 733 Type NKX
HTM Circulation Pumps acc. to DIN EN 733 Type NKX General The new NKX pump line replaces our former heat transfer oil circulation pump type NKL s. The outer dimensions of both pump types are identical
More informationSelfpriming Centrifugal Pumps. Type HZS/HZSA
Selfpriming Centrifugal Pumps Type HZS/HZSA General The selfpriming multistage DICKOW-centrifugal pump is designed for handling hydrocarbons and other volatile liquids. The HZS-type is used in tank farms,
More informationNEOTeCHA Reactor Sampling Type PV
A safe and reliable sampling device to meet the demands of the chemical and pharmaceutical industry Features General applications To take a sample from reactors or vessels containing: poisoned media s
More informationCRN A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html
More informationKTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet
KTZ22.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429
More information1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.
FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment
More informationSay heating. Say Herz. HERZ-Supply Engineering
HERZ-Supply Engineering Medium Temperature Control Pressure Control Fittings Control Fittings Lock Shields and Isolators Accessories Spare Parts Say heating. Say Herz. HERZ Valves UK Progress House [ Moorfield
More informationSTEAM TRAPS
STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct
More informationDLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:
DLKF A. General: Provide submersible sewage pumps suitable for continuous duty operation underwater without loss of watertight integrity to a depth of 65 feet. Pump system design shall include a guide
More informationFor calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1
Centrifugal Pump Single Shaft Seal 2 Freephone lines are open between 8.00am and 5.30pm Monday to Friday FREEFAX: 0800 801404 TETRA PAK PUMPS Centrifugal Pump Single Shaft Seal Motors: 3000 r/min, 3-phase
More informationWorldwide Contacts. Technical Data
Worldwide Contacts www.tyco-fire.com Model BFV- Butterfly Valve Wafer Style General Description The TYCO Model BFV- Wafer Style Butterfly Valves are indicating type valves designed for use in fire protection
More informationMARINE. High efficiency pumps you can rely on
DESMI MARINE PUMPS High efficiency pumps you can rely on Vertical In-Line Pumps - Mainstream Designs Our latest design in vertical in- Double suction pumps for the Pumps for the low capacities. line pumps.
More informationSeries 759 FireLock Alarm Check Valve
R IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS 10.70 Series 759 FireLock Alarm Check Valve Grooved Grooved PRODUCT DESCRIPTION U L FM U L C See Victaulic publication 10.01 for details. The Victaulic
More informationTECHNICAL DATA. Wet 26a. February 22, 2009
February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve
More informationKRAL Screw Pumps. L Series.
KRAL Screw Pumps. L Series. Our new Medium Pressure Pump The new L pump makes life easier sturdy, with a low wear rate and easy to maintain. How the L pump fits into the KRAL product Applications. range.
More informationEKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata
EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata
More informationTechnical Data. Sizes 2 12 Inch (DN50 DN300)
Worldwide Contacts www.tyco-fire.com Model BFV- Butterfly Valve Wafer Style General Description The TYCO Model BFV- Wafer Style Butterfly Valves are indicating type valves designed for use in fire protection
More informationModel: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40
1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically
More informationCentrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL
Centrifugal Pumps acc. to EN 22858 / ISO 2858 with Shaft Sealing Type NCL General The DICKOW centrifugal pump acc. to EN 22858 / ISO 2858 is designed for handling liquids in the chemical and petrochemical
More informationHRS035-MS-022-RD 22 (559mm) 19mm x 30m 310mm Fixed Manual. HRS037-GI-019-RD 19 (483mm) 19mm x 36m 350mm Swing Manual
FIRE HOSE REEL CertIFIeD to Bs en 671-1: 1995 Certification No: Ps005704 BRITISH STANDARDS INSTITUTION APPROVAL FIRE HOSE REELS CERTIFIED TO BS EN 671 LICENCE NO. KM 51857 Certified Product AUSTRALIAN
More informationCRN90-1 A-F-G-V-HQQV 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN9-1 A-F-G-V-HQQV 3x4D 5 HZ Grundfos Pump 96124237 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn9/96124237/crn-9-1-a-f-g-v-hqqv.html
More informationHennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA)
Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA) 2013-09-16 Tank Station for Coil and Fan Door Production Item B ITEM NO. DESCRIPTION
More informationSECTION METERS AND GAGES FOR PLUMBING PIPING
SECTION 220519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationF4060 RESILIENT SEATED GATE VALVES
F4060 RESILIENT SEATED GATE VALVES BS 5163 AS 2638 EN 1074 FM UL EN 1171 ISO 7259 The Keystone Figure 4060 series is a Tyco manufactured resilient seated gate valve available in a wide variety of configurations
More informationSekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS
Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Wastewater is a demanding process, performance, day in day out. Xylem challenges, providing trusted
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION The renewed ETN-Lined pumps are singlestage, magnetic driven, centrifugal pumps in closecoupled execution. ETN-Lined pumps are available both inpp+gf and ETFE. The pump casing is
More informationSpare parts list ( ) Spare parts list PUZZI 100 *USA
Spare parts list (5.958-246.0) Spare parts list PUZZI 100 *USA 14.12.2012 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list PUZZI 100 *USA (5.958-246.0)... 6 10 Tank water (0.162-794.0)...
More informationSpare parts list ( ) Spare parts list PUZZI 100
Spare parts list (5.958-029.0) Spare parts list PUZZI 100 10.02.2012 www.kaercher.com EN Table of contents Spare parts list PUZZI 100 (5.958-029.0)... 6 10 Tank water PUZZI 100 (0.162-640.0)... 7 20 Appliance
More informationEssex County College - West Essex Campus Addition And Renovations dlb # / 11-14
SECTION 210523 - GENERAL-DUTY VALVES FOR WATER-BASED FIRE-SUPPRESSION PIPING PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationRefrigerant Valves/Accessories
Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating
More informationTechnical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)
Worldwide Contacts www.tyco-fire.com Model BFV-/BFV-C Butterfly Grooved End General Description The TYCO Models BFV- (Normally Open) and BFV-C (Normally Closed) Grooved End Butterfly s are indicating type
More informationFIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator
FIRE EXTINGUISHERS Chapter 2 - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator CO2 FIRE EXTINGUISHER - Dielectric test at 35000 V at 1mtr distance.
More informationDeluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design
Fire Protection Div. Dorot Fire Protection Division Deluge Valves Model 68 DE\ EL Electrically Actuated Remote-Reset Deluge Valve Certification & compliance by design 1 ANSI FCI 70-2 Class VI seat leakage
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationOperating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage
Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationBall Float Steam Trap with Integral Spiratec Sensor and Flanged Connections
Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationSL EX.4.51D
GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html
More informationGFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE
Item 1) TWO THERMAL OIL HEATERS OF 1200 kw EACH 1.1) THERMAL OIL HEATER BODY Brand PIROBLOC Model GFT-060/40/H2 Power 1200 kw Delta Temperature 40 ºC Execution Horizontal Designed and built According AD-2000
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationD. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationFlow Control for Fire Protection
Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality
More informationCentrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL
Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL General The DICKOW centrifugal pump, type NCL, is designed for handling liquids in the chemical and petrochemical industry, in refineries,
More information#2 ECLIPSE POST HYDRANT PARTS LIST. O-Ring for Top Screw (requires 2 per screw)
SMALL ORDR CHARG Orders of $25 or less will be subject to a $10 small order fee. Orders $25.01 to $50 will be subject to a $5 small order fee. #2 CLIPS POST HYDRANT PARTS LIST # PHOTO PART NUMBR DSCRIPTION
More informationKUBOTA Double suction volute pump
PUMPS CATALOGUE KUBOTA Double suction volute pump DV-L type J series KUBOTA Corporation DOMESTIC OFFICES AND OVERSEAS OFFICE E-Mail:pump@kubota.co.jp http://www.kubota.co.jp/english KUBOTA Double suction
More informationFull-line Product Overview
Full-line Product Overview End Suction Centrifugal Pumps This general purpose pump can be configured in frame-mounted and close-coupled, semi-open and enclosed impeller configurations. They are available
More informationCBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet
CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More informationCleaning System. Amajet. Type Series Booklet
Amajet Type Series Booklet Legal information/copyright Type Series Booklet Amajet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed
More informationFire protection network
Fire protection network In case of a fire, water is still the extinguishing media number one. It is then important that enough water is immediately available for the fire fighters in order to save lives
More informationKTV DEWATERING PUMPS
www.tsurumi-global.com DEWATERING PUMPS Submersible Lightweight Compact Dewatering Pumps Tsurumi -series features submersible pumps of lightweight compact design. The pump body is made of die-casted aluminium
More informationOil burners fuel unit with solenoid valve
Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve
More informationChemical Pumps Vertical Chemical Pump Type TNP
Chemical Pumps Vertical Chemical Pump Type TNP In PP / PE-UHMW / PVDF Vertical setting depths up to 00 mm Applications Type TNP vertical chemical pumps are specifically designed to handle acids, alkalis
More informationPENGUIN SERIES HSC PUMPS INTRODUCTION
PENGUIN Installation & Maintenance SERIES HSC PUMPS MODELS HSC-1/4 HSC-1/2 HSC-3/4 HSC-1 HSC-2 HSC-3 SEALS S - Single D - Double M - Single/Multi-Stage INTRODUCTION Penguin 316 stainless steel centrifugal
More informationVogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM
Vogel Pumpen Vogel - Blockpumps Design LMN / LM 1 Materials: Design LMN, Sizes DN 32-80 Design LM, Sizes DN 100-150 Performance: Capacity up to 500 m 3 /h (2200 USgpm) Head up to 95 m (312 feet) Speed
More informationTorqueflow Sydex. Fluid Management. K Range Pumps
Torqueflow Sydex Fluid Management K Range Pumps The extremely popular K-range is a heavy-duty robust industrial pump designed for a wide range of applications throughout a multitude of industries. Available
More informationSECTION METERS AND GAGES FOR HVAC PIPING
SECTION 23 0519 METERS AND GAGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Thermometers. 2. Gages. 3. Test plugs. 4. Thermowells. 1.2 SUBMITTALS A. Product Data: For each type
More informationVD 53 - Vacuum drying oven for non-flammable solvents
Vacuum drying ovens VD 53 - Vacuum drying oven for non-flammable solvents The VD series offers safe drying with homogenous temperature distribution, thanks to its APT.line air jacket system. ptimum heat
More informationTransformer oil coolers BETA & CETA
2012.1 Transformer oil coolers BETA & CETA Transformer oil coolers BETA & CETA Luvata is pleased to present to the market its renewed transformer oil coolers. The BETA and CETA series of transformer oil
More informationCombiBloc Close-coupled centrifugal pumps
CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular
More information#2 ECLIPSE POST HYDRANT PARTS LIST. O-Ring for Top Screw (requires 2 per screw)
SMALL ORDR CHARG Orders of $25 or less will be subject to a $10 small order fee. Orders $25.01 to $50 will be subject to a $5 small order fee. #2 CLIPS POST HYDRANT PARTS LIST # PHOTO PART NUMBR DSCRIPTION
More informationD-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS
D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS GENERAL: This document provides performance requirements and guideline information for Heat Exchanger equipment for Colorado College only, and is not
More informationPRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM
ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup
More information1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W
594 59P0 Flow switch for liquids in piping DN 0 00. QE90 Contact load / switching capacity: Nominal pressure PN5 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free
More informationCAP SERIES SEWAGE AND WASTE WATER PUMPS
Part 8 CAP SERIES SEWAGE AND WASTE WATER PUMPS TECHNICAL SPECIFICATIONS : Turbosan CAP series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and
More informationModel CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts
Worldwide Contacts www.tyco-fire.com Model CV-F Grooved End Swing Check Valves General Description The TYCO Model CV-F Grooved End Swing Check Valves are compact and rugged swing-type units that allow
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,
More informationPRODUCT INFORMATION. Liquid ring vacuum pumps Liquid ring compressors. Series LVP
PRODUCT INFORMATION Liquid ring vacuum pumps Liquid ring compressors Series LVP Contents Description Description... 2 Design... 3 Application range... 4 Material and performance range... 5 Functional principle...
More informationKQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800
KQ Series Multistage Booster Pump System Installation Manual KQ200/400 KQ800 ISO 9001 Certified Description The KQ series booster pump is an all-in-one compact and reliable automatic multistage centrifugal
More informationCondensate drains WA/PWEA
Condensate drains WA/PWEA Condensate drains WA Function -Q- Temperature range 0 +60 C -L- Operating pressure 1.5 16 bar -H- Note In order to close, the automatic condensate drain WA-2 requires a flow rate
More informationTP /4-A-F-A-BQQE 400D 50HZ
GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html
More informationTechnical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm
HEGA Horizontal Multistage Pump Brief Introduction HEGAHorizontal Multistage Pump is the new multistage product series, the excellent hydraulic performance and structure of which have enabled low cost
More information4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction
4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation
More informationEnd-Suction Centrifugal Pump
GH End-Suction Centrifugal Pump GH Horizontal end-suction pump for handling water, oils and chemicals in marine, process and general industrial applications. Hydraulic performance extends to 2,500 GPM
More informationEnd-Suction Centrifugal Pump
GH End-Suction Centrifugal Pump GH Horizontal end-suction pump for handling water, oils and chemicals in marine, process and general industrial applications. Hydraulic performance extends to 2,500 GPM
More information