CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Similar documents
ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

Thermostatic mixing valves with replaceable cartridge for centralized systems

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

Thermostatic mixing valves with interchangeable cartridges

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Dynamic thermostatic radiator valves DYNAMICAL

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

anti-condensation valve

FOR INSTALLING AND USING

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

product overview ProControl

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

caleffi hydronic valves page 1 of 12

heat interface units A BOILER WITHOUT A FLAME

Inta City Concealed Shower Mixing Valve CT80010CP

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

INTA ION MODERN BAR / BATH SHOWER MIXER CP

DISCALDIRT deaerator-dirt separator

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide

Mercury Mixing Kit (Code: ME1053)

Inta City Shower Mixing Valve CT20010CP

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning

Telo Shower Mixing Valve TL10016CP

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Deluge Shower Mixing Valve 10045CP

Plus Bath Shower Mixing Valve CP and PL30020CP

Systems for central heating

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS

Puro Mini Dual Control Shower Mixer PU90010CP

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Installation and Servicing Instructions. Alpha FlowSmart

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Kiko Bath Shower Mixing Valve KK90015CP

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Mio Concealed Shower Mixing Valve MI40010CP

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Hydronic Mechanical Panels

Composite under-boiler dirt separator with magnet DIRTMAG

INTADUO THERMOSTATIC BATH/SHOWER MIXER

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

aquablend thermostatic mixing valves

The Safety Valve Specialist Thermostatic Shower Controls

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

Hot water circulation system WZS 100

The New Caroma TMV20

Thermostatic Bar Valves

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Exclusive Green E Condensing Wall-Hung Boilers

CAST IRON ATMOSPHERIC BOILERS

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Automatic Temperature Controller (ATC)

Enzo Concealed Shower Mixing Valve

MAXIMISER Semi-Storage Calorifiers

TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS

INSTALLATION AND SERVICING

Deluge Concealed Shower Mixing Valve DL40010CP

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

Installation, Operating and Maintenance Guide

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

SEALED THERMAL STORE

High Capacity Instantaneous Steam Fired Water Heater

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

DEVIATING VALVES ART K063

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

Kiko Concealed Shower Mixing Valve KK80010CP

geothermal march 2011

THERMOSTATIC MIXING VALVES

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

Instructions for Use Installation and Servicing

CALEFFI. SEP4 combination hydraulic, air, dirt and magnetic separator series 01249/13.1 NA. Replaces 01249/13 NA. Function.

CATALOGUE NUMBERS. Pressure Reducing Valve (PRV)** Mains Supply. Cold Water Outlets

Transcription:

Solar storage-to-boiler thermostatic connection kit 6-63 series REGI STERED BS EN ISO 900:000 Cert. n FM 64 UNI EN ISO 900:000 Cert. n 0003 CLEFFI 064/09 GB Function The solar storage-to-boiler connection kits automatically control and optimise the thermal energy contained in the solar water storage, ensuring that domestic hot water is distributed throughout the system at a controlled optimum temperature. They ensure that users always receive hot water at the set temperature and switch the boiler on if the temperature of the water coming from the solar storage falls below the set point. The kits are available in two versions, to be coupled with various boiler kinds, with storage or istantaneous. Depending on the version, they are supplied complete with thermostatic diverter valve, special thermostatic control device designed to prevent boiler hunting and anti-scald thermostatic mixing valve. These compact kits are designed for quick and easy installation in both new and existing systems. They come complete with a pre-formed shell protective cover. Patent application No. MI0080083. Product range Code 630 SOLRINCL-T. Solar thermostatic connection kit to boilers with storage size 3/4 Code 6330 SOLRINCL-T PLUS. Solar thermostatic connection kit to instantaneous boilers size 3/4 Technical specifications Materials Thermostatic mixing valve Body: - 6 series: dezincification resistant alloy EN 6 CW60N, chrome plated - 63 series: dezincification resistant alloy EN 98 CB7S, chrome plated Obturator: PSU Springs: stainless steel Seals: EPDM Knob: BS Diverter valve and thermostatic control device Body: - 6 series: brass EN 6 CW67N, chrome plated - 63 series: dezincification resistant alloy EN 98 CB7S, chrome plated Obturator: PSU Springs: stainless steel Seals: EPDM Cover: BS Union seals: non-asbestos fibre Protective cover 6 series Material: PVC Thickness: 7 mm Density:,9 kg/dm 3 Working temperature range: - 0 C Reaction to fire (EN 30-): class B 63 series Material: EPP Thickness: mm Thermal conductivity: 0,037 W/(m K) at 0 C Density: 0,04 kg/dm 3 Working temperature range: - 0 C Reaction to fire (UL 94): class HBF Connections: - inlet and outlet: 3/4 M with union - boiler: 3/4 M Performance Thermostatic mixing valve Medium: drinking water Max. working pressure: 0 bar (static); bar (dynamic) Max. inlet temperature: 00 C djustment temperature range: 3 C Factory set: 43 C ccuracy: ± C Max. inlet pressure ratio (H/C or C/H): : Min. temperature difference between inlet hot water and the outlet mixed water to ensure anti-scald performance: 0 C Min. flow rate for stable operation: 4 l/min Performance to standards: NF 079 doc. 8, EN 09, EN, EN 87 Thermostatic diverter valve Max. working pressure: 0 bar Max. differential pressure: bar Max. inlet temperature: 00 C Factory set: 4 C ccuracy: ± C Thermostatic control device Max. inlet temperature: 8 C Factory set: 30 C ccuracy: ± C

Dimensions E F B C D Code 630 3/4" B 66, C 08, D 40 E 8 F 4, Weight (kg),7 High temperature and solar systems In solar thermal systems with natural circulation in the primary circuit and a water storage with heating jacket, the temperature of the domestic water in the storage can vary considerably depending on the degree of solar radiation and can reach very high temperatures over long periods. In summer, and if there is little water usage, the hot water at the storage outlet can actually reach temperatures around 98 C before the temperature and pressure safety relief valves are actuated. t these temperatures, the hot water cannot be used directly, because of the danger of scalding for users. Water temperatures over 0 C can cause burns very quickly. For example, at C, partial burn occurs in about 30 seconds, whereas at 60 C partial burn occurs in about seconds. It is therefore necessary to use a thermostatic mixing valve able to: - reduce the temperature of the water distributed throughout the domestic water system to a value lower than that in the storage and suitable for the end user. For reasons of safety, it is recommended to set the temperature of the mixed water distributed to the users to values no higher than 0 C; - keep mixed water temperature constant despite variations in inlet temperature and pressure; - continue functioning over time without any loss in performance and without problems due to the continuously high temperature of the incoming water; - enable the high temperature water in the storage to last longer, by distributing it to the user circuit at a reduced temperature; - have an anti-scald safety function in case of failure of the cold water supply. Integration with boiler Solar domestic water storages are normally installed in conjunction with boilers or water heaters. In this way, boilers or water heaters can be switched on to produce domestic hot water when solar radiation is insufficient, therefore the thermal energy available within the storage is low. The following actions are necessary to control this type of system automatically and ensure the correct distribution of domestic hot water: - install a suitable thermostatic diverter valve between the solar circuit and the boiler or water heater, to divert hot water automatically in accordance with its temperature; - switch the boiler or water heater on if the temperature of the solar hot water is insufficient; - connect the solar hot water circuit to the boiler or water heater according to the functioning mode of the boiler or water heater, which can be instant modulating or equipped with its own storage.

Characteristic components ) Thermostatic diverter valve ) nti-scald thermostatic mixing valve Operating principle thermostatic diverter valve, at the kit inlet, receives hot water coming from the solar water storage. Depending on the temperature set (factory set: 4 C), the valve diverts the water automatically and in a proportional manner towards the user circuit or the boiler with storage circuit, with thermal integration. The valve modulates the flow rates to optimise the energy contained in the solar storage and reduce boiler operation times to a minimum. thermostatic anti-scald mixing valve, at the kit outlet, constantly controls the water temperature sent to the user. Hydraulic diagram BOILER M M SOLR T SOLR > 4 C

63 series SOLRINCL-T PLUS Characteristic components Operating principle ) Thermostatic diverter valve ) Thermostatic control device 3) nti-scald thermostatic mixing valve Cold water inlet 3 Outlet to boiler Inlet from boiler thermostatic diverter valve, at the kit inlet, receives hot water coming from the solar water storage. Depending on the temperature set (factory set: 4 C), the valve diverts the water automatically and proportionally towards the user circuit or the instantaneous boiler circuit, with thermal integration. The valve modulates the flow rates to optimise the energy contained in the solar storage and reduce boiler operation times to a minimum. specific thermostatic control device limits the boiler inlet temperature to prevent it being switched on and off too often, which leads to hunting and irregular operation. n anti-scald thermostatic mixing valve, at the kit outlet, constantly controls the water temperature sent to the user. Hydraulic diagram Mixed water Inlet outlet from solar storage BOILER BOILER M C D M C D SOLR SOLR T SOLR > 4 C T SOLR < 4 C

Construction details Operational flexibility The kits are made using a single casting, so as to minimise their overall size and make installation easier. They are supplied complete with components used for control and operation, designed for direct connection to the circuit without sections of piping having to be fitted between the various devices. High resistance to temperature The internal control components of the diverter valve and the mixing valve are designed to maintain constant performance with inlet hot water temperatures up to 00 C, in continuous operation. nti-scale materials The materials used when constructing the kit were selected to eliminate seizing due to limescale deposits. ll functional parts have been made using a special anti-scale material with low friction coefficient, which ensures over time performance. Diverter valve Mixing valve Diverter valve The thermostatic diverter valve at the kit inlet features a built-in sensor, which is immersed directly in the flow of hot water coming from the solar storage. Through the action of the thermostat controlling obturator movement, the flow rate is adjusted proportionally and automatically, without the need for external energy sources. This means there is no need for other temperature probes in the circuit and electrical wiring procedures. Thermostatic control device If used in conjunction with instantaneous boilers, the water temperature at the boiler inlet may reach certain values (T>3 C) which prevent the boiler from modulating enough the thermal power transferred to the medium. Low flow rates may lead to the boiler being switched on and off too often, with consequent hunting that prevents the boiler from operating efficiently. The thermostatic control device in the 63 series limits the occurrence of this phenomenon, as it keeps the water temperature at the boiler inlet at a constant low value (T=30 C) by mixing the solar hot water coming from the diverter valve with the cold water at the inlet. This means the boiler always operates with a suitable thermaldifference between the inlet and the outlet, resulting in optimal management of the energy produced. Thermostatic mixing valve special anti-scald thermostatic mixing valve offering high thermal performance is positioned at the kit outlet in order to control the temperature and protect the user. The mixing valve keeps the temperature of the hot water at the kit outlet, supplied to the user, at a constant level, even in the event of variations in temperature and pressure at the inlet or flow rate requested. T > 4 C T < 4 C nti-scald safety function s a safety measure, in case of failure of the cold water supply, the valve immediately shuts off the flow of the hot water. This prevents dangerous burns. This performance is guaranteed if there is a minimum temperature difference between the inlet hot water and the outlet mixed water of 0 C. lso in case of failure of the hot water supply, the valve shuts off the cold water port and thus the outlet mixed water to prevent dangerous thermal shocks. Thermal transient During transient, following rapid changes in pressure, temperature or flow rate, the outlet mixed water temperature increases with respect to the initial set point and this increase must be of limited duration to guarantee safety. The anti-scald mixing valve always ensures that these conditions are respected. T( C) 60 C C Initial temperature Temperature rise Control device < s - max < 3 s - max Stabilisation period Stable conditions K K Time (s)

Diverter-mixing valve coupling The diverter-mixing valve coupling on the Solarincal T storage-toboiler thermostatic connection kit allows the mixing valve to rotate through 360 to satisfy all the possible installation needs. The kit comes complete with a special pre-formed protective cover. pplication Solar storage-to-boiler connection kits are generally installed near the boiler, on the pipe of the hot water coming from the solar storage, to ensure a constant temperature of the mixed water supplied to the user. Given their flow rate characteristics, thermostatic kits can be installed to control water temperature both for single user points (e.g. washbasins, bidets, showers) and for multiple users. To ensure that the mixed water is supplied at the set temperature, a minimum flow rate of 4 l/min must be ensured to the kits with thermostatic mixing valves. Checking the head loss in the kit If the design flow rate is known and taking into account the simultaneous use of sanitary appliances, the head loss produced by the kit can be checked using the diagram. It is necessary to check the available pressure, the head loss in the system downstream of the kit and the residual pressure to be guaranteed to user devices. Installation Before installing the kits, the pipework must be flushed to ensure that no circulating impurities can compromise their operation. It is recommended to install always strainers of adequate performance at the water inlet from the hydraulic network. The kits must be fitted according to the installation diagram provided in the instruction manual or in this brochure. The kits can be installed in any position, vertically or horizontally. Hydraulic characteristics of the 6 series Δp (bar), Tsol > 4 C Tsol < 4 C Δp (m w.g.),0 Kv (m 3 /h) with Tsol > 4 C =,3 with Tsol < 4 C =, 0 0,3 0, 0, 0,0 0, 0 0 0 Hydraulic characteristics of the 63 series 3 Flow rate (l/min) (m 3 /h) Bracketing The 63 series connection kit is supplied complete with a special wallmounting bracket. This simplifies the installation process and makes connection easier while ensuring a secure support. Check valves In systems with thermostatic mixing valves, check valves shall be installed to prevent undesired backflow. The kit with mixing valve incorporates check valves on the hot and cold water inlets. Δp (bar),,0 Kv (m 3 /h) with Tsol > 4 C =, with Tsol < 4 C =, Tsol > 4 C Tsol < 4 C Δp (m w.g.) 0 Commissioning In view of the special applications for which the thermostatic mixing valve is used, it must be commissioned according to current regulations, by qualified technicians equipped with suitable temperature measurement instruments. We recommend using a digital thermometer for measuring the mixed water temperature. 0,3 0, 3 Temperature adjustment The temperature of the mixed water is set to the desired value by means of the control knob on the thermostatic mixing valve. 0, 0,0 0, 0 0 0 Flow rate (l/min) (m 3 /h)

Temperature setpoint adjustment The diverter valve is factory adjusted to operate at a temperature of 4 C, diverting water to the boiler if the temperature falls below this setpoint value. The set temperature value is fixed using a locking ring. The 63 series thermostatic control device is factory set and fixed to keep constantly at 30 C the temperature of the water at the boiler inlet. Factory configurations Diverter valve: 4 C Thermostatic control device: 30 C pplication diagrams 6 series Thermostatic Solarincal - natural circulation solar system Shut-off valve Pressure reducing valve Discharge tundish Check valve T/P safety relief valve Temperature gauge Expansion vessel T Thermostat Pump WTER INLET Safety relief valve 6 series Thermostatic Solarincal - forced circulation solar system Normally closed valve WTER INLET

MODULTING BOILER WTER INLET SPECIFICTION SUMMRIES 6 series Solar thermostatic connection kit to boilers with storage. Inlet and outlet connections 3/4 M with union. Boiler connections 3/4 M. Medium drinking water. Complete with: - Diverter valve with chrome plated brass body. PSU obturator; stainless steel springs; EPDM seals; BS cover. Union seals in non-asbestos fibre. Maximum working pressure 0 bar; maximum differential pressure bar; maximum inlet temperature 00 C; factory set 4 C; accuracy ± C. - nti-scald thermostatic mixing valve with dezincification resistant alloy body, chrome plated; PSU obturator; stainless steel springs; EPDM seals; BS control knob. Maximum working pressure (static) 0 bar, bar (dynamic); temperature adjustment range 3- C; factory set 43 C; accuracy ± C. Maximum inlet temperature 00 C; maximum ratio between inlet pressures (H/C or C/H) :; minimum temperature differential between hot water inlet and mixed water outlet to ensure anti-scald performance 0 C; minimum flow rate for stable operation 4 l/min. Performance to standards: NF 079 doc. 8, EN 09, EN, EN 87. Complete with a PVC pre-formed shell protective cover. 63 series Solar thermostatic connection kit to instantaneous boilers. Inlet and outlet connections 3/4 M with union. Boiler connections 3/4 M. Medium drinking water. Complete with: - Diverter valve with dezincification resistant alloy body, chrome plated. PSU obturator; stainless steel springs; EPDM seals; BS cover. Union seals in non-asbestos fibre. Maximum working pressure 0 bar; maximum differential pressure bar; maximum inlet temperature 00 C; factory set 4 C. ccuracy ±%. - Thermostatic control device with dezincification resistant alloy body, chrome plated. PSU obturator; stainless steel springs; EPDM seals; BS cover. Union seals in non-asbestos fibre. Maximum inlet temperature 8 C; factory set 30 C; accuracy ± C. - nti-scald thermostatic mixing valve with dezincification-resistant alloy body, chrome plated; PSU obturator; stainless steel springs; EPDM seals; BS control knob. Maximum working pressure (static) 0 bar, bar (dynamic); temperature adjustment range 3- C; factory set 43 C; accuracy ± C. Maximum inlet temperature 00 C; maximum ratio between inlet pressures (H/C or C/H) :; minimum temperature differential between hot water inlet and mixed water outlet to ensure anti-scald performance 0 C; minimum flow rate for stable operation 4 l/min. Performance to standards: NF 079 doc. 8, EN 09, EN, EN 87. Complete with a EPP pre-formed shell protective cover. We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. CLEFFI CLEFFI S.P.. I 800 FONTNETO D GOGN (NO) S.R. 9, N. TEL. +39 03 849 R.. FX +39 03 86373 www.caleffi.com info@caleffi.com Copyright 009 Caleffi