Disinfectant Boost System DBS-125 Owner's Manual

Similar documents
INSTRUCTION MANUAL HS-229G

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

TrueClean ToteCleaner

Owner s Manual Hydro-X Vacuum Pac

Thanks for shopping with Improvements! Solar Pool Heater XF Item #

Air Pump Up to 800 gallons

TrueClean ToteCleaner

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Printed in U.S.A Rev. A 6/2005 0B

Patent Pending invent for New Construction

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

SolarPRO CONTOUR HEATER OWNER S MANUAL

Congratulations on your AK275 Purchase!

Sound Cover [ , , , ]

SolarPRO XD3 HEATER OWNER S MANUAL

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Installation Instructions PP-AS20 Anti-Scale System

SolarPRO CURVE HEATER OWNER S MANUAL

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

SYSTEM CONTROL KIT Model: CK-41P

Installation and Maintenance "L" and "LS" Series

Air Dryers & After Coolers Dry Land

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

Compact Equipment Warranty Policy

User Manual. Juice Extractor MODEL: WJE2BSLA

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Clean Steam Generators

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

120 VAC SYSTEM CONTROL KIT

FW-RA-LED Remote Multiplex Annunciator Panels

ispring Whole House Water Filter Systems USER S MANUAL

CD6102 / CD6102 OC / CD6102-2

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

TUBULAR LLdia-PUMPyy INSTRUCTIONS

FLASH XTRACTOR II NEXT GENERATION SUB-SURFACE FLOOD EXTRACTION TOOL AC002

DOM MODEL SERIAL NUMBER VOLTAGE/HERTZ/PHASE

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Owner & Operator Manual

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

Inline Heater for Solvent or Gas. Installation and Operation Manual

ion Genesis Pump Controller

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Desiccant Air Drying System

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Xaact Spot. Xaact Hot Spot

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

OPERATING INSTRUCTIONS

Installation Instructions AS-WH Whole House Water Filter

User s Manual and Operating Instructions

Owner & Operator Manual

Desiccant Air Drying System

Hg5 Amalgam Separator Installation and Operations Manual

MaxLite LED MICRO-T PANEL

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

GLOBAL LIFT CORP. Owner s Manual. Home Series

OWNE R S MA N UA L. Made in USA. September 2015

Syclone Amalgam Separator Installation and operating guide

Quest PowerHeat HFC 100 Pro

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Flat Line Spray Systems Kits

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Owner s Manual Phoenix Aquadry TX 200

120 VAC SYSTEM CONTROL KIT Model: CK-63

55-Gallon Dispenser Package

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

Model R060 Installation - Operation Manual

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy.

SYSTEMS for CATALYTIC FILTERS

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

Installation Instructions / Warranty

NOTICE TO INSTALLER: Instructions must remain with installation. FW Supersedes HomeGuard OPTIMA

V LPM Desiccant Air Dryer Installation and Operation Manual

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

Owner's Manual. Whole House Water Softener with Triton Electronic Control Valve. or call

Table of Contents Important Safeguards 2 Introduction 3 Installation 4 Operation 5 Cleaning Pattern 5 Automatic Shutoff and Removal 6 Maintenance 6

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

14+ SEER R-410a AIR CONDITIONERS. Aluminum Coil Series. Efficiencies up to 14+ SEER/12 EER. Nominal Sizes Ton. Capacities 16.

LBC MANUFACTURING Simple Solutions for Effluent Disinfection

OPERATING INSTRUCTIONS

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Full Extension Soft-Close Undermount Drawer Slide

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

A2Z Ozone, Inc. PRODUCT MANUAL

Green Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Transcription:

Disinfectant Boost System Owner's Manual www.medoraco.com 866-437 - 8076 info@medoraco.com _Owners_Manual_20180829

Table of Contents Disinfectant Boost System Owner's Manual Table of Contents Safety 1 Features 2 Operation 3 Specifications 7 Customer Service 8 About Medora Corporation Medora Corporation combines knowledge and experience from across the water quality spectrum to help solve real-world problems. Whether in Lakes, Stormwater Retention Ponds, Raw Drinking- Source Reservoirs, Water Treatment Plants, Potable Storage Tanks, or Wastewater Treatment Processes, equipment continues to be at the forefront as the #1 world leader for in-situ water body treatment. 1910_20170390 _Owners_Manual_20180829

Safety Be sure you have read all installation, operation, maintenance and safety instructions before you install, service or begin to operate this unit. Accidents occur every year because of careless use of industrial equipment. You can avoid hazards by following these safety instructions, and applying some ordinary common sense when operating or servicing this unit. Keep in mind that full operator attention and alertness are required when operating or servicing this unit. USE COMMON SENSE!! Most acccidents can be avoided by using common sense and concentration on the job being done. WARNINGS / PRECAUTIONS: Please check all hose clamp connections to make sure clamps and ittings are tight. Even though all ittings are factory tightened and checked, clamps may have settled into the hose material during transportation and may require an additional tightening before the irst start-up of the unit. Periodic checking should also be considered as preventative measures for the safety of the operators. IMPORTANT!!! PLEASE FOLLOW ALL LOCAL AND STATE LAWS IN REGARDS TO SAFETY OF HANDLING AND TRANSPORTING NaOCl. PLEASE USE NECESSARY PPE WHEN HANDLING NaOCl OR USING THIS DISINFECTANT BOOST SYSTEM. REFER TO THE PROPER MATERIAL SAFETY DATA SHEETS FOR ADDITIONAL PRECAUTIONS AND SAFETY MEASURES. 10232_20180808 _Owners_Manual_20180829-1

Features The Medora Corporation Disinfection Boosting System,, is speciically designed to pump the full range of concentrations of Sodium Hypochlorite. The design enables this system to be portable, operated by a wide range of portable air compressors, and allows the user to dose, rinse and air purge at multiple locations with a single unit. COMPACT, CONTAINED, AND PORTABLE DESIGN User friendly design featuring a disinfectant holding tank and fresh water rinse tank. Secondary self containment is integrated into the frame structural design. The unit is portable and easily its in small to full sized pick-up boxes. SELF-PRIMING CONFIGURATION Pump location allows looded suction from both disinfectant and rinse water holding reservoirs. Pump is located inside containment enclosure for minimized user exposure and safe operation. CORROSION RESISTANT COMPONENTS All wetted material components are of chemical compatibility with Sodium Hypochlorite. Stainless steel hardware and containment on non-wetted parts are utilized for atmospheric corrosion resistance. FLOW AND LIQUID LEVEL INDICATION Visible liquid level of chemical holding tank, with level indicators precise to fractions of a gallon. THREE STAGE CHEMICAL BOOSTING SYSTEM Easily dose disinfectant with the high performance Air-Operated Double Diaphragm (AODD) pump discharging at a rate of 0.5gpm to 4.0gpm at heads up to 125psi or +200 ft. Easy liquid selection valve operation to switch from pumping chemical to pumping rinse water. Three-way main control valve allows user to switch from pumping disinfectant to pumping rinse water and to purge injection lines dry using the same air compressor operating the AODD pump. Air Disinfectant Water BENEFITS Frequent boosting with small doses of chlorine is far less costly than having a major problem occur in a tank. This portable disinfectant boosting unit allows you to dose smaller amounts of chlorine more frequently allowing your tanks to be maintained within your desired chlorine residual levels. With frequent monitoring and this portable boosting unit you can give your customers quality water they deserve. 10233_20180808 _Owners_Manual_20180829-2

Operation The is designed to operate with an air compressor capable of producing 4cfm at 60psi. An air compressor is required to operate this system and is not included with the purchase of this product. Connecting the to your potable water tank: Be sure to check and secure all connections before starting the disinfectant boost unit. This unit comes equipped with a 30 ft discharge hose to connect the disinfectant boost unit to the injection port of your potable water tank. The injection hose is equipped with Banjo quickconnect ittings to easily adapt to the disinfectant boost unit and to SolarBee circulation equipment chemical injection lines. Locate the discharge port on the side of the control panel of the disinfectant boost unit. Remove the protective dust cap and set aside. Connect the mating end of the 30 ft discharge hose to the discharge port engaging both cam levers to make a secure connection. Connect the opposite end of the 30 ft discharge hose to your potable water tanks injection port, also engaging both cam levers of the quick connect ittings for a secure connection. Open any valves in line with the injection port of the potable water tank, if applicable. Connecting the air compressor to operate the : Before connecting the air supply to the disinfectant boost unit, please be sure that the main control valve is turned to the OFF position. Once the main control valve is turned to the OFF position, the air supply can now be connected to the Compressor Quick Connect itting (Milton Type M). There are different styles of air ittings, so you may be required to change out this itting if it is not compatible with your type of air compressor quick coupler. Air supply quick connection ittings can be purchase at most automotive or hardware stores. This itting can easily be changed out to accommodate your air compressor. A-Style S-Style P-Style Automotive Style G-Style T-Style Type M Once the air supply is connected to the disinfectant boost unit, adjust the air pressure using the Pressure regulator. Set the air pressure to 75psi. Never allow air pressure to exceed 125psi. This may damage certain components of the disinfectant boost system. 10234_20180808 _Owners_Manual_20180829-3

Operation, cont. Selecting the desired liquid for discharge: Now that you have all connections made to safely dose your potable water tank, you will have to select which holding tank to pump from depending on the desired liquid you would like to pump. Using the below diagram, turn only the corresponding valve to the open position to pump your desired liquid. The DISINFECTANT valve will allow dosing from the 20 gallon storage tank as labeled on the disinfectant boost units tank cover. The RINSE WATER valve will allow dosing from the 5 gallon storage tank as labeled on the disinfectant boost units tank cover. To start dosing your tank, irst make note of the liquid level site tube gauge on the side of the DISINFECTANT 20 gallon holding tank. Turn the DISINFECTANT valve to the OPEN position. Dosing your potable water tank: Turn the main control valve to the PUMP position. This will allow air to low from the air compressor to the AODD pump to start pumping from the selected holding tank. Use the Flow Regulator needle valve to adjust the rate of which you would like to dose. Dosing should occur between 0.5gpm and no greater than 4.0gpm. DISINFECTANT Knowing the amount of disinfectant you would like to boost, use the site tube gauge to dose the desired amount of disinfectant. Turn the main control valve to the OFF position once you have dosed the desired amount of disinfectant. CLOSE the Disinfectant Valve and OPEN the RINSE WATER valve. Turn the main control valve back to the PUMP ON position to pump a small amount of rinse water, approximately 1 gallon, from the 5 gallon holding tank. The rinse water will push the remaining disinfectant through the injection line at the desired injection rate between 0.5gpm and no greater than 4.0gpm. WATER 10234_20180808 _Owners_Manual_20180829-4

Operation, cont. Purging the injection lines: Now that the desired amount of disinfectant is completely injected, slowly turn the main control valve to the PURGE position. This will use the air from the air compressor to purge the injection line free of the remaining water and residual disinfectant in the injection line. Turn the main control valve to the OFF position after approx. 3 to 5 seconds of purging. WATER 3-5 seconds Flushing the injection lines: In order to keep your injection lines free from disinfectant scaling, it is necessary to lush the lines clean of any disinfectant residual. With the Rinse Water Valve in the OPEN position, repeat the dosing instructions by turning the main control valve to the PUMP position. Dose only a small amount of rinse water, approximately 0.125 gallons, from the 5 gallon holding tank. WATER Once a small amount of rinse water is pumped into the injection lines, turn the main control valve to the PURGE position for approximately 3 to 5 seconds. This will push the rinse water quickly thru the injection lines washing the line of the remaining disinfectant residual. Repeat these lushing steps 3 to 4 times, pumping approximately 0.125 gallons of rinse water and purging for 3 to 5 seconds. WATER 15 seconds 3-5 seconds Note: The pump may lutter briely after each purge cycle as the pump is self priming. This is a normal occurrence. 10234_20180808 _Owners_Manual_20180829-5

Operation, cont. Once you feel the injection lines are thoroughly rinsed, complete a inal purge cycle. Purge the injection lines a inal time for approximately 15 seconds. This will remove most of the moisture from the injection lines to prevent damage to the injection lines due to freezing or scaling. 15 seconds You have now successfully dosed your potable water tank using the Medora Corporation DSB-125 system. Make sure the main control valve and both liquid selection valves are all turned to the OFF or Closed positions before disconnecting the 30 ft discharge line from the potable water tank or from the disinfectant boost unit. Once the disinfectant boost unit is turned OFF, you may turn off and disconnect the air compressor from the unit. The below basic operating instructions decal is located below the control panel of the product for your convenience. 10234_20180808 _Owners_Manual_20180829-6

Summary Speciications Technology Description: AODD Pump: Air Compressor: (not included) Skid/Base: Chemical Hose: Chemical Compatibility Holding Tank: Dimensions Warranty: Safe, durable chemical transfer system to boost disinfectant in potable water reservoirs. Air Operated Double-Diaphragm pump. Capacity of 0 to 4 GPM discharge. Displacement per stroke of 0.1 gallons. Heads up to 125 psi or 288 ft of water. Portable (ie. gas engine) oil-less air compressor required to operate system. Air compressor not included. 4cfm at 60psi required. Compressor should be capable of 125 psi if desired to run the pump at maximum pressure rating. 316 stainless steel construction. Provides secondary containment. 30 feet of 3/8" lexible Telon chemical hose jacketed with stainless steel braid sheathing. 250psi max pressure. Constructed of Polypropylene, CPVP, Telon, and Viton. All materials compatible with 12.5% sodium hypochlorite, maximum temperature of 100 F and 30% calcium hypochlorite (liquid form only). 20 gallon capacity disinfectant holding tank, and 5 gallon capacity rinse water tank. High density linear polyethylene (HDLPE) material construction. 20 W x 24 H x 56 L, 150 lbs (dry weight), 350 lbs (full capacity wet weight) Limited 1 year parts and labor warranty. Identify all possible hazards. Determine what safeguards are needed and implement them. Only you, the user, understand your product and system characteristics fully. The ultimate responsibility for safety is with you. Your safety ultimately rests in your hands. Do your part and you will enjoy safe, trouble free operation for years to come. MEDORA CORPORATION S LIMITED REPLACEMENT WARRANTY: All new and factory-refurbished Medora Corporation equipment is warranted to be free of defective parts, materials, and workmanship for a period of 1 years from the date of installation or delivery. This warranty is valid only for use of the Medora Corporation equipment in accordance with the owner s manual and any initial and ongoing factory recommendations. This warranty is limited to the repair or replacement of defective components only except for the irst 1 years the warranty includes both parts and labor. In lieu of sending a factory service crew to the site for minor repairs, the seller may choose to send the needed parts to the owner postage paid and pay the owner a reasonable labor allowance to install the parts. There are no other warranties of any type, express or implied, and there is no liability for consequential damages of any type. EXCEPT AS STATED ABOVE, MEDORA CORP. AND ITS AFFILIATES EXPRESSLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES ON PRODUCTS FURNISHED HEREUNDER, INCLUDING WITHOUT LIMITATION ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Please consult your state law regarding this warranty as certain states may have legal provisions affecting the scope of this warranty. IN NO EVENT WILL MEDORA CORP. OR ITS AFFILIATES BE LIABLE FOR ANY DAMAGES CAUSED BY FAILURE OF BUYER TO PERFORM BUYER S RESPONSIBILITIES OR FOR FOLLOWING MEDORA CORP. ADVICE. IN NO EVENT WILL MEDORA CORP. OR ITS AFFILIATES BE LIABLE FOR ANY LOST PROFITS OR USE OR OTHER PUNITIVE, SPECIAL, EXEMPLARY, CONSEQUENTIAL, INCIDENTAL OR INDIRECT DAMAG- ES, HOWEVER CAUSED, ON ANY THEORY OF LIABILITY, WHETHER OR NOT MEDORA CORP. HAS BEEN ADVISED OF SUCH DAMAGES, OR REASONABLY COULD HAVE FORESEEN THE POSSIBILITY OF SUCH DAMAGES, OR FOR ANY CLAIM AGAINST BUYER BY ANOTHER PARTY. Patent Pending Subject to change without notice. 10235_20180829 _Owners_Manual_20180829-7

Service & Support Medora Corporation Service & Support Medora Corporation employs qualiied highly trained Service and Placement Technicians certiied to perform the necessary tasks required to install or remove SolarBee and GridBee circulation equipment. Medora's specialized Service and Placement Technicians are trained in Conined Space, Fall Protection, and other related subjects as required by OSHA to perform the necessary work to install or remove SolarBee and GridBee equipment, and are knowlegeable in the regulations and standards of OSHA. If you feel the need to service your SolarBee or GridBee circulation equipment, please contact Medora's Customer Service Department at: +1 866 437 8076 10001_20180222 _Owners_Manual_20180829-8