U538 12/11. Zoning. Replaces: 08/10. tekmarnet 4 Thermostat 538. User Manual. 1 of U /11

Similar documents
552_U 09/14. tekmarnet Thermostat 552 Zoning Replaces: 08/11. User Manual. 1 of 12. A Watts Water Technologies Company _U - 09/14

Thermostat TP42H01 User Manual

- Application Boiler Control 260

- User Brochure tekmarnet 4 Setpoint Control 161

Zoning Solutions. Thermostats & Wiring Centers Designed to Maximize Indoor Comfort. A Watts Water Technologies Company

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

- User Brochure Programmable Thermostat 510

- Data Brochure tekmarnet 4 Thermostat 542e

Better Design, Better Control, Better Systems.

- Data Brochure Addendum

- Data Brochure Addendum

- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1

4 Wiring Brochure Wiring and

- Essay Control Functions and Benefits

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

Installation & Operation Manual

Installation & Operation Manual

- Data Brochure Boiler Control 274

- Data Brochure Steam Control 279

Daikin Altherma high temperature remote controller guide for schedule timers and operation functions

Installation & Operation Manual

Owner s Manual. Part Number 33CSCPACHP-01

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

- Data Brochure D 260. Boiler Control /09

- Data Brochure Universal Reset Module 422

- Data Brochure Universal Reset Module 423

Installation & Operation Manual

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

Hydronic & HVAC Control Systems

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

Radiant Thermostat 519

Installation Instructions

Installation & Operation Manual

Installation & Operation Manual

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

User s Manual

Commercial Touchscreen Thermostat

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Installation & Operation Manual

Installation & Operation Manual

- Data Brochure D 261. Boiler Control 261

OPERATING INSTRUCTIONS

- Data Brochure Mixing Control 360

Instruction Guide: Thermostat Operation

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

Installation & Operation Manual

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

Installation & Operation Manual

VIGÖR HRV PLUS AND VIGÖR ERV

81M26 81M27 81M28. User's Manual. Menu Driven Display DELUXE PROGRAMMABLE THERMOSTATS

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

Operating Instructions

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

Owner s Manual MODEL 8555

- Data Brochure Boiler Control 264

ST9400A User Guide. Features

ComfortSense 7500 Commercial Thermostat. User Guide

Installation & Operation Manual

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

- Data Brochure Boiler Control 268

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

Programmable Towel Radiator Manual

DAY/TIME Button: Selects hour, minute and day setting.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

Elegance. SMT-700 User manual. Ver

Programmable Touchscreen Thermostats. Read all instructions before proceeding. Store this manual for future reference

ATC32U03 igate Communicating, Programmable Thermostat

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

OWNER S MANUAL. Part Number P CONTENTS

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

Installation Instructions

ELECTRONIC THERMOSTAT

Lyric T6 & T6R Smart Thermostat

KELCO F29 PROGRAMMABLE FLOW SWITCH

WARNING Important Safety Information

SAT-3 Room Temperature Controller

SMART 2000 Digital Programmable Thermostat Owners Manual Robertshaw 2/

Quickheat 30 weather compensated boiler control

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

RC-1000 and RC-2000 Programmable Communicating Thermostat. User s Guide

Underfloor heating. user guide. DS thermostats with timeclock. Nu-Heat v18 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

INTRODUCTION WHAT THE EMS-1000 IS DESIGNED TO DO HOW THE EMS-1000 OPERATES EMS CONTROL PANEL INITIAL SETUP SETUP CLOCK DIGITAL DISPLAY

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

SAS6000UTK-7 UNIVERSAL THERMOSTAT

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

O CRC100. Comfort Room Controller (2015/01) en

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat.

Transcription:

tekmarnet 4 Thermostat 538 User Manual Zoning U538 12/11 Replaces: 08/10 1 of 12 2011 U 538-12/11

This brochure will provide you with the information you need to benefit the most from your tekmarnet thermostat. Please visit www.tekmarcontrols.com for more detailed information on this or any other tekmar product. This thermostat provides heating for one zone in your building. It will maintain your air temperature with an on board ROOM sensor, but may also have an auxiliary ROOM, FLOOR, or OUTDOOR sensor attached. A ROOM sensor will allow control of a location other than the one in which the thermostat is installed. An outdoor sensor will allow this and all other tekmarnet thermostats in your building to display the outdoor temperature on their displays. A floor sensor will allow this thermostat to control your floor temperature. This thermostat can maintain floor temperature only, air temperature only, or floor and air temperature together. With the addition of one of tekmar s energy saving accessories, this thermostat can also lower its temperature setting at night or when you are away from the house. Temperature Adjustment This thermostat can operate at day or night temperatures (see Day or Night Temperatures section) for ROOM or FLOOR settings. The temperature can be adjusted as follows: Step 1: Press the or button until the desired temperature is displayed. Step 2: Release all buttons and wait for the display to return to normal operation. The adjusted settings will be saved in memory. ROOM or FLOOR displays depending on configuration Indicates whether the day or night temperature is being set (if available). Adjustment Buttons Adjust the temperature You will be adjusting the temperature of the current operating mode. To adjust temperature settings that are not shown on the screen, you must enter into the Adjust Menu as described in the Adjust Menu section. There may be other symbols on the screen that affect thermostat operation. Please see the Display Symbols section for a description of each symbol. 2011 U 538-12/11 2 of 12

Adjust Menu This thermostat has an Adjust Menu that allows adjustment of all of its settings. The following items can be adjusted or viewed: Day and night temperatures (if available) Floor temperatures Backlight on-time Temperature units F or C Thermostat type (view only) The Adjust Menu can be accessed as follows: Step 1: Press and hold the and buttons until the desired setting is shown (a new screen will appear every 2 seconds). Step 2: Press the or button to adjust the temperature setting. Step 3: Press and hold the and buttons again to advance to the next adjustable setting. Repeat steps 1 and 2 until all adjustments have been made. Step 4: Release all buttons and wait for the display to return to normal operation. The adjusted settings will be saved in memory. Indicates setting is in the Adjust menu Indicates the name of the setting being adjusted Press and Hold and together Indicates whether the day or night temperature is being set (if available). This thermostat has access levels. It will typically be installed and programmed by a heating professional and then locked in a User access level. System critical settings will not be available for adjustment. For more information on these settings, please consult your installing contractor or this product s Installation and Operation Manual. The following pages describe the settings available to the User. 3 of 12 2011 U 538-12/11

Day and Night Temperatures This thermostat is capable of running at a lower temperature setting when you are asleep or out of the building. An energy saving accessory can be added to your tekmarnet system in order to activate these energy saving setback temperatures. If one is connected, day and night temperature settings will be available. They are adjusted as follows: Step 1: Press and hold the and buttons to enter the Adjust Menu, and wait until the desired setting is shown with the day symbol on the screen (a new setting will appear every 2 seconds). Step 2: Press the or button to adjust the temperature setting. Step 3: Press and hold the and buttons until the same setting is shown with the night symbol on the screen. Step 4: Press the or button to adjust the temperature setting. Step 5: Release all buttons and wait for the display to return to normal operation. The adjusted settings will be saved in memory. Setting Day or Night tekmarnet Energy Saving Accessories ---------------------------- 479 User Switch With the touch of a button, tell every thermostat in your house to operate at their night setback or Away temperature. Press and Hold and together Examples of these settings are as follows: 2011 U 538-12/11 4 of 12 033 Timer Program a night setback schedule for all of your thermostats with one device. Mode of Operation day night ROOM example: 70 F (21 C) 65 F (18 C) FLOOR MINIMUM example: 72 F (22 C) OFF Note: The presence of a schedule is indicated by the clock symbol.

Floor Temperatures If your thermostat has a floor sensor connected to it, floor temperature can be maintained. This allows you to have warm floors even during milder times of the year when the air temperature is warm enough or when your air conditioning is on. Floor temperature can be maintained in two ways. Air temperature can be ignored and the thermostat will maintain Floor Temperature Only. Or, air temperature can be considered and the thermostat will maintain Floor and Air Temperatures together. Floor Temperature Only -------------------------------------------- If the air sensor has been disabled, the thermostat will only maintain floor temperature and ignore air temperature. In this mode, the desired floor temperature can be adjusted as described in the Temperature Adjustment section. Floor and Air Temperature ------------------------------------------ If the air sensor is turned on and their is a floor sensor connected, the thermostat will maintain your desired air temperature as well as a minimum floor temperature. However, the floor minimum temperature will override the air temperature, and if set too high, may overheat the room. The FLOOR MINIMUM temperature is adjusted through the Adjust Menu as follows: Step 1: Press and hold the and buttons to enter the Adjust Menu, and wait until the FLOOR MIN setting is shown as well as the desired day or night symbol (a new screen will appear every 2 seconds). Step 2: Press the or button to adjust the temperature setting. Step 3: Release all buttons and wait for the display to return to normal operation. The adjusted settings will be saved in memory. Setting Day or Night Press and Hold and together 5 of 12 2011 U 538-12/11

Floor Temperature Settings ---------------------------------------- Setting a floor temperature is a way of enhancing the comfort of your living space. Radiant floors heat the air by raising the floor temperature. During milder times of the year when the air temperature is warm enough without the need for heating, floors can cool off. A floor minimum setting can ensure that the floors stay warm during these periods, or even in the summer when the air conditioning is on. Sun shining into a room can keep it warm without the need for heat. This can allow the floors to cool off. And when the sun goes down, it can sometimes take a long time for the floors to get warm again. This may cause the room to cool off too much in the early evening. A floor minimum setting can help with this condition. The following are some typical floor temperature settings that have been used with tekmar thermostats. NOTE: Setting a floor temperature that is too high can damage floors or make the room uncomfortably warm. If a FLOOR MIN is set, the thermostat will maintain the floor at this temperature regardless of the air temperature. And the air temperature may exceed that to which it is set. 90 F (32 C) Feels hot to the touch 80 to 85 F (26 to 30 C) Feels warm to the touch 70 F (21 C) Feels cool to the touch Suggested maximum for all floor types other than wood. Bathrooms and kitchens. Suggested maximum for wood floors. Rooms with large windows preventing underheating in the evening. 40 to 45 F (5 to 7 C) Feels cold to the touch Freeze protection for garages. Wood Floors ------------------------------------------------------- Rapidly changing or excessively high temperatures can cause damage to wood flooring. Ask your heating professional about setting the floor maximum if your flooring is a type that can be damaged by heat. 2011 U 538-12/11 6 of 12

Changing the Backlight This thermostat has an LED backlight that can be configured as follows: Off Permanently Off. 30 Temporary on for 30 seconds (when a button is pressed) On Permanently On On + On during and off during Press and Hold and together. Step 1: Press and hold the and buttons to enter the Adjust Menu, and wait until this screen appears (a new screen will appear every 2 seconds). Step 2: Press the or button to adjust the backlight operation. Step 3: Release all buttons and wait for the display to return to normal operation. The adjusted setting will be saved in memory. 7 of 12 2011 U 538-12/11

Changing the Units ( F or C) This thermostat can display temperatures in F or C. Press and Hold and together. Step 1: Press and hold the and buttons to enter the Adjust Menu, and wait until this screen appears (a new screen will appear every 2 seconds). Step 2: Press the or button to adjust the units. Step 3: Release all buttons and wait for the display to return to normal operation. The adjusted setting will be saved in memory. 2011 U 538-12/11 8 of 12

Display Symbols In addition to the features described in this manual, there may be others operating in the background. Among others, this thermostat will display symbols on its screen in order to indicate what mode it is in, what temperature it is operating at, or what equipment it is trying to turn on. This section describes each of those symbols. Schedule Symbols These symbols appear when a Schedule Master or User Switch is connected to the system. Those devices will tell this thermostat what temperature setting to operate at (day, night, or ). Refer to the Day and Night Temperatures section for more information. A Schedule Master is present in the system and this thermostat is following that Master s programmable schedule. Operating at the Day temperature. If there is no Schedule Master or User Switch in the system, the thermostat will always be in this mode. Operating at the Night temperature. A setback enabling accessory or Schedule Master thermostat has enabled setback. Operating at the Away temperature. If flashing, the temperature cannot be adjusted by pressing the up or down arrows. Consult the Installation and Operation Manual for this product for more information on this feature. If flashing, the system is in Warm Weather Shut Down. The outdoor temperature is above the WWSD setting. No heating will take place while in WWSD. However, if a floor sensor is attached and a minimum floor temperature is set, it will be maintained. 9 of 12 2011 U 538-12/11

Equipment Operating Symbols These symbols indicate the current status of the system. Heating is turned on. The thermostat is part of an Air Group (a group of heating zones within a commonly ducted air-conditioning system) and the air-conditioning within that group is on. This thermostat will be locked out of heating when this symbol is displayed, which will save energy. Communication Symbols These symbols appear when this thermostat is part of a network and/or when there is something wrong in the system. The thermostat is part of a network and is communicating with other devices in the network. There is something wrong with the thermostat or the tekmarnet system. This usually occurs if a control component has failed or is set up incorrectly. Contact your installing contractor for more information or consult the Installation and Operation Manual for this product. 2011 U 538-12/11 10 of 12

Frequently Asked Questions Symptom Look for... Corrective Action No heat or not enough heat and pressing button does not increase temperature Heat on before scheduled time Pressing button does not decrease temperature H1 Symbol Flashing WWSD Flashing Away Flashing MAX Flashing MIN H1 symbol indicates heat is on. If the H1 symbol is displayed and you still have no heat, you may have an issue with your heating appliance. Consult your heating professional. Increase WWSD setting on tekmarnet reset control. Press a user switch button other than Away (typically or ) or go to your Scenes page on your gateway and change the scene to Occ or Unocc The thermostat has a maximum floor or air temperature set that is preventing the heating system from providing a higher temperature. Call your installer or refer to the Installation and Operation Manual for information on how to adjust maximum room and floor temperature settings. Optimum start learns the heat up and cool off rate of the room and starts the heating or cooling early so that the room is comfortable at the scheduled time. There may be a minimum room or floor temperature set. Consult your heating professional. More Information This User Brochure contains standard information on how to make adjustments to an installed product. More detailed information can be found in this product s Installation and Operation Manual (D538) at www.tekmarcontrols.com 11 of 12 2011 U 538-12/11

Save Even More Energy - the Easy Way Great Accessories for Your tekmarnet System User Switch 479 With the touch of one button, every part of your home can switch between Day, Night & Away temperature settings. While Away on vacation, domestic water heating can be suspended to save even more. Day (Comfort) Night (Economy) Away (Best Economy & DHW Suspend) Timer 033 Let the system automatically switch between Day and Night temperatures to match your schedule. The Timer 033 can manage setback for all of the thermostats in your system from a central location. Ask your installer about adding a tekmarnet User Switch or Timer to add more energy saving convenience to your system. All specifications are subject to change without notice tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road Vernon, B.C. Canada V1B 3K4 (250) 545-7749 Fax. (250) 545-0650 Web Site: www.tekmarcontrols.com Product design, software and literature are Copyright 2011 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 12 of 12 U 538-12/11.