Retroreflective sensor with polarization filter

Similar documents
Retroreflective sensor with polarization filter

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

Plug-in Base, Long Range Sensor E3B2

Sensing light curtain as per DIN 18650/EN 16005

Sensing light curtain as per DIN 18650/EN 16005

PHOTOELECTRIC AMPLIFIER SERIES

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Assembly. Connection overflow sensor. Connection fat level sensor OFF ON

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

BOS 23K. Photoelectric Sensors BOS 23K

General Specifications

2 General Application Photoelectric Sensors

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

2 General Application Photoelectric Sensors

Automatic Self-Adjusting General Purpose Sensor

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Room thermostats with LCD for wall mounting

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

Retro-reflective Sensing range: 0mm to 2000mm

Reflective Optical Beam Smoke Detector User Guide

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Topscan G3 Presence detector for automatic doors

Online data sheet WS/WE45-P260S01 W45 PRODUCT PORTFOLIO

5.0. Photoelectric Sensors. Technical Reference. Introduction

Danfoss gas detection units

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

Class 1 laser beam sensor safe for your eyes

Vibracon LVL-A* Level limit switch for liquids, compact design

UNIVERSAL COMPACT SENSORS

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

General Specifications. Small size Fast 500µs response time Cable or quick-disconnect options 11 28V DC Operating Voltage Red output LED indicator

Series PHOTOSWITCH Photoelectric Sensors. Standard and Timing. Description. Supplied Accessories

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

Class 1 laser beam sensor safe for your eyes

E3M-V. Mark Sensor. Applications

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

Class 1 laser beam sensor safe for your eyes

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

Laser Collimated Beam Sensor

D-Tect 2 GJD300 Quad PIR Movement Detector

1. Basic safety information 3 2. Proper use 3

General Purpose Photoelectric Sensor

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Table of Contents. 1. Mounting Tips... 2

Lonworks Damper Interface Catalogue

MINI-BEAM Expert Series

SVP Series. Photoelectric Sensors Smart Value Photoelectric WARNING WARNING. MICRO SWITCH Sensing and Control. Introducing the NEW AC Version!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

O P Style Meter with Optical Sensor Switch

Polarized Retroflective Photoelectric Switches

Danfoss gas detection units

/ / 2018

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Application guide RDG160 Remote control

Flush-mounted room thermostats

E3FA PHOTOELECTRIC SENSORS

INFRARED MODULATED BARRIERS

More Precision. thicknesssensor // The sensor for precise thickness measurements

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

Original operating instructions Safety switch with guard locking AC901S AC902S

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

FIRERAY 5000 range USER GUIDE

The Affordable, All-Purpose Sensor That's EZ To Use!

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

FlowJam Bulk Flow Detection

compact office 24V compact office 24V Lux

Safety Light Curtains Area Access Control

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Line Smoke Detector LRMX

Technical Data. Dimensions

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Fire Damper Interface (24V)

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Danfoss gas detection unit Type GD Heavy Duty

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

COMPACT FLAME CONTROLLER CFC 2000

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

43.155/1. RXE 110: Monitoring unit for fume cupboards. Sauter Components

compact office 24V compact office 24V Lux

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Room thermostat with Auto Timer, Option External Input

SPACEMOTION SERIES SMM 01

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Fire Damper Interface (230V)

Room air quality sensors

Transcription:

Dimensions 45 49 Receiver 27 74 Emitter 92 56 23 6 x 9 slots S 23 25 32 Internal thread (1/2-14 NP) External thread (M30 x 1.5) ø 6 mm Cable 10 Model Number Retroreflective sensor with fixed cable Features Cost-optimized series for standard tasks in a special design Compact design Wide range of mounting options thanks to cubic housing design with M30 thread 360 high visibility LEDs Programmable -delay, -delay, and One-shot timers Version for universal voltages Relay output Electrical connection BN L1/+UB BU N/0V WH NC BK NO GY C he relay-functions "NC" and "NO" bear on the switching mode "Dark-". his complies to the default setting of the light/dark switch (factory setting). Product information he Series 61 sensor family is a comprehensive product line, offering five sensing modes. Each sensor is equipped with four LEDs that are highly visible from all directions, indicating Power-On, target presence and marginal excess gain. he widely recognized, polycarbonate housing provides a IP67 protection degree rating. Color-coded labels are clearly printed on the housing to easily identify the sensing mode. DC models offer a 4-in-1 output while AC/DC models have a SPD relay output rated to 3 A. All versions come standard with an integral multifunction timer, sensitivity adjustment and Light-/Dark- switch. Series 61 sensors are cross-talk protected and have a high degree of resistance to ambient lighting. Each sensor can be mounted via front and rear slots, rear dovetail guide or M30 x 1.5 mounting base. Additionally, cabled sensor models provide ½" - 14 NP internal threads for use with flexible conduit. Indicators/operating means 1 2 3 4 5 Sens Delay IMER 1 Operating display green 2 Signal display yellow 3 Sensing range adjuster 4 ime adjuster 5 DIP-switches 1

echnical data General specifications Effective detection range 0... 18 m Reflector distance 0.3... 18 m hreshold detection range 25 m Reference target FE-RR1 reflector Light source LED Light type modulated visible red light, 630 nm Polarization filter yes Diameter of the light spot approx. 350 mm at a distance of 18 m Angle of divergence 1.1 Optical face frontal Ambient light limit 5000 Lux ; according EN 60947-5-2 Indicators/operating means Operation indicator 2 LEDs green Function indicator 2 LEDs yellow on: reflector inside the sensing range off: reflector outside the sensing range Control elements Light/Dark switch Control elements Detection range adjuster Control elements ime adjuster ( 0... 10 s ) Electrical specifications Operating voltage U B 24... 240 V AC 12... 240 V DC No-load supply current I 0 35 ma Protection class II, rated voltage 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC Power consumption P 0 2 VA Output Switching type light/dark on, switchable Signal output 1 SPD relay Switching voltage max. 250 V AC/DC Switching current max. 3 A Switching power DC: max. 150 W AC: max. 750 VA Switching frequency f 20 Hz Response time 25 ms imer function DIP-switch for selection of operating modes Ambient conditions Ambient temperature Storage temperature Mechanical specifications Degree of protection Connection Material Housing Optical face Mass ightening torque, fastening screws Cable length -40... 55 C (-40... 131 F) -40... 70 C (-40... 158 F) IP67 2 m fixed cable PC (Polycarbonate) PMMA approx. 240 g 2 Nm 2 m Compliance with standards and directives Directive conformity EMC Directive 2004/108/EC EN 60947-5-2:2007 + A1:2012 Standard conformity Product standard EN 60947-5-2:2007 IEC 60947-5-2:2007 Standards EN 50178, UL 508 Approvals and certificates UL approval CCC approval culus Listed, ype 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 240 V AC/DC Certified by China Compulsory Certification (CCC) Accessories MPZB01 Mounting bracket with vertical slots MPZB02 Mounting bracket with circular slots MPZB06 Ball and Swivel Mounting Bracket MPZB07 Ball and Swivel Vertical Mounting Plate Other suitable accessories can be found at www.pepperl-fuchs.com 2

Curves/Diagrams Movement Characteristic RL(K)-61-55-Z 200 150 100 Offset Y [mm] 50 0-50 -100-150 -200 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 x y Reflector C110-2 FE-RR1 H85 H50 Distance X [mm] 60 Excess Gain vs. Sensing Distance RL(K)61-55-Z 50 Excess Gain 40 30 Reflector C110-2 FE-RR1 H85 H50 20 10 0 x 5000 10000 15000 20000 25000 Distance X [mm 3

imer Functions Switching ype Detection Status Light Received L. Operation Mode No Light Received imer No Delay (imer ) imer elay imer elay imer One-Shot Delay imer elay and elay Switching ype Detection Status Light Received D. Operation Mode No Light Received imer No Delay (imer ) imer elay imer elay imer imer DIP-Switch position ime () is adjustable from 0 to 10 sec One-Shot Delay elay and elay 4

Adjustment Instructions Intended use: he retroreflective sensor contains the emitter and receiver in a single housing. he light from transmitter is reflected back from a reflector to the receiver. If an object interrupts the light beam, the switching function is initiated. Mounting instructions: he sensor can be mounted using the through-holes or with a mounting bracket (not included with delivery). he base surface must be flat to avoid distorting the sensor housing during mounting. It is advisable to secure the bolts and screws with washers so that the sensor does not become misaligned. Adjustment Instructions: Connect the sensor to operating voltage and the green LED lights up solid. Mount a suitable reflector opposite the sensor and make a rough adjustment. he precise adjustment is done by swiveling the sensor horizontally and vertically. With optimum light reception, the yellow LED lights up solid. It will blink if the sensor requires fine adjustment. Object detection: Move an object into the light beam. If the object is detected, the yellow LED switches off. If it does not switch off, reduce the sensitivity with the potentiometer until it does. It should light up solid when the object is removed. Cleaning: he yellow LED flashes if the light received decreases (e.g. dirty lenses). We recommend that you clean the optical interfaces and check all connections at regular intervals. 5