PCXGA13. Air-Cooled PRODUCT SYSTEM. Residential. Light Commercial. All Product. Commercial / Industrial. Catalogue. For internal reference only R22

Similar documents
Inverter Wall Mounted Series

Inverter Y Series.

Inverter Wall Mounted

Inverter Wall Mounted

Ceiling Mounted Cassette Unit

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

Ceiling Mounted Cassette Unit

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

Inverter Wall Mounted

RC-0219-A. Single-Split Non Inverter Series

PLXSID1605. Warning HEAD OFFICE :

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Air conditioners Cooling only

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems 12K - 18K - 24K

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Wall Mounted Split Systems G-Series AP - MWM - G - 06A

Pure air. Because Daikin cares

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

LV Series. SEER 20+ Wall Mount Heat Pump

Non Inverter Wall Mounted Series

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

M-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Residential and Light Commercial Ductless Systems Catalog

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

PHOTOCATALYTIC AIR CLEANER

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

DAIKIN AIR PURIFIER IMPROVED BREATHING COMFORT FOR ALLERGY AND ASTHMA SUFFERERS ABSOLUTE COMFORT

Technology that works fast. Hi-Wall Split Systems

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

Multi Digital Scroll System (R-22 and R-410A)

Wall Mounted Split Systems

Inverter console UFV system. Compact design and personalised air flow selection

Technology that works fast. Hi-Wall Split Systems

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

MARKETING BULLETIN. Unitary Product WALL MOUNTED G SERIES MBM

we care about Better Air

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

eco Touch Premium Toshiba Airconditioning March 2016 For more details, please contact our sales office:

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

HI-WALL SPLIT SYSTEMS

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Owners Manual Model: XXL

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Up to SEER 26.1 Wall Mount Heat Pump

EDAU Air Purifiers. Engineering Data MC70LPVM

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com

The Comfort and Luxury You Deserve

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

2017 LINE UP MINI SPLITS CATALOG

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

Product Specifications. Vertical Floor Consoles By First Co.

A single answer for multiple zones.

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

Inventor of the Inverter Digital Inverter System

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

(Non-Inverter & Inverter) R410A

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

WHYNTER Eco Pure Air Purifier

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

A single answer for multiple zones.

Light commercial range. Passion at work

ROOFTOP PACKAGED AIR CONDITIONERS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

HEPASilent Air Purification Systems. Clean air is a human right

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

DAIKIN S URURU SARARA

HEPASilent Air Purification Systems. Clean air is a human right

Samsung 360 Cassette, Single Zone, Split System

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Transcription:

PCXGA13 Air-Cooled PRODUCT SYSTEM Residential Light Commercial All Product Commercial / Industrial Catalogue For internal reference only R22

Since its establishment in 1974, OYL has developed into a large air conditioner manufacturer in Malaysia, serving both local and export market. OYL Group became part of Daikin Industries Ltd of Japan in 2006, making the combined group the second largest HVAC (Heating, Ventilation and Air Conditioning) organization in the world. The integration of Daikin and OYL Group has enabled OYL to capitalize on each other's strengths and compensate for each other's weaknesses as well as develop business and improve profitability in ways not possible individually. By 2006, OYL has expanded the manufacturing facility covering a land space of 115,214m 2 with a built-up area of 86,249 m 2. It houses 11 production lines with the maximum production capacity of 2.2 million units per annum, producing unitary products for residential, light commercial and industrial applications ranging from 2k to 220k. The manufacturing plant is certified to ISO 9001: 2008 Quality Management System ISO 14001: 2004 Environmental Management System OHSAS 18001: 2007 Occupational Safety and Health Management System Contents Residential Series OYL is committed to provide innovative and quality products to customers. This is evident by the establishment of OYL R&D Centre in 1998, to focus on product research and development. It has one of the largest air-conditioner test laboratories in South East Asia, for performance tests up to 230k. Our R&D capabilities include: Quality 02 all Mounted J Series 14 Psychrometric test room facilities 4 which are ETL Approved Performance Test Facilities by ETL Cortland, USA 1 anechoic chamber and 1 reverberation chamber for sound test SMT (Supervised Manufacturer's Testing) accredited laboratory by Intertek SEMKO for performance test, CB safety test and EMC test Component test laboratory for component qualification Air flow laboratory for fan and blower test and qualification ide Range of Product Light Commercial Series Affordability 09 Ceiling Cassette E Series 12 Ceiling Cassette C Series 15 Ceiling Convertible E Series 17 Ceiling Exposed C Series 19 Ceiling Concealed C Series Commercial / Industrial Series QUALITY e ensure the highest quality of our products, subjecting it to various safety tests before placement into market. Besides that, all units are produced under strict production quality standard. IDE RANGE OF PRODUCT e design and manufacture a large array of air conditioners ranging from 2k to 220k for various applications. AFFORDABILITY e strive to offer cost effective products without compromising on quality. 26 Ceiling Concealed D & E Series 30 Ducted Split 36 Air-Cooled Rooftop Package A Series Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly. All specifications are subjected to change by the manufacturer without prior notice. 39 Air-Cooled Rooftop Package C Series

Model Range all Mounted Single Split J Series all Mounted Single Split F Series Ceiling Cassette E Series Ceiling Cassette C Series Model Range FT(Y)09/10/15/20/25JXV1 Ceiling Convertible E Series, Ceiling Exposed C Series FL(Y)15/20/25/28/35/40/50EXV1 FH(Y)62CXV1 FT(Y)30FXV1 FH(Y)C20/25/28/40/50EXV1 Model Range Ducted Split D & E Series Air-Cooled Rooftop A Series FD125/150DXY1, 2FD200DXY1 FDY125/150EXY1, 2FDY200EXY1 (2-4)FG250/300/400/500DXY1 (2-4)FGY250/300/350/400/450/500/600/EXY1 Ceiling Concealed C Series FD(Y)B10/15/20/25/30/40/50/60CXV1 FD(Y)M10/15/20/25/28/30/38/40/50/60CXV1 Ceiling Concealed D & E Series FDM75/100EXV1 FD(Y)M75/100DXV1 UAT180/240/280/320/450/560/700/850AMY1 UATC10/12AMY1 FF(Y)10/15/20CXV1 Ducted Split B & C Series FD125BXY1 FDY125CXY1 FD(Y)150BXY1 2FD(Y)200BXY1 (2-4)FG(Y)250/300/350/400/450/500/600BXY1 Air-Cooled Rooftop C Series UAT150/180/240/300CXY1 Products Overview

all Mounted 2 Residential Series all Mounted J Series FT(Y)09/10/15/20/25JXV1 1 2

Stylish Flat-Panel Ideal blend of style and function. Regular cleaning is easier by just wiping the flat front panel. This ensures the air-conditioner looks brand new at all time. Better Air Quality (IAQ) Using Bio-Engineering IAQ solution which combines superior cleansing and purifying of Bio Antibody filter with more effective deodorizing features of Titanium Apatite filter. orking in tandem, both technologically-advanced air filters offer higher level of IAQ and room comfort. Bio Antibody Filter Protection 1 Bio-engineering is the fusion of life science with engineering principles that creates exciting new solutions to considerably enhance the needs of modern lifestyle. Using advanced bio-engineering techniques, the Bio Antibody filter is able to eliminate up to 99.99% of various airborne infectious viruses to provide a cleaner and more purified living environment. Protection 2 - Titanium Apatite Filter Micron-scale fibers trap dust while titanium apatite absorbs organic contaminants such as bacteria and viruses. In addition, the titanium oxide is activated by natural light, allowing it to break down and eliminate odours. The filter effectively deactivates bacteria and viruses. It lasts for three years without replacement if washed about once every six months. Titanium Oxide Photocatalytic deodorizing filter Mechanism of photocatalyst: - Titanium Oxide is activated by exposure to light. - Becomes highly oxidative. - Dissolves absorbed substances into harmless water (H 2 O) and carbon dioxide (CO 2 ). Step 1 Step 2 Absorption of dangerous airbone particles like dust, pollen and cigarette smoke. Dissolves odour, bacteria and virus. Step 3 Bio Antibody Filter In Action Antibody Deactivates 99.99% of airborne infections viruses within 1 minute Natural Sunlight Bio-Antibody Filter Special filter material that contains antibodies hen photocatalyst is exposed to light, it is activated and absorbs odour particles A chemical reaction decomposes the odours into CO 2 and H 2 O The odourless substance is then released into the air. Deactivated even if it becomes airborne again. No longer harmful to room occupants. Air is fresher. Airborne Virus Free floating viruses and antigen causes potential health hazards and discomfort to the room occupants Absorption power is more than doubled, dissolution force is increased. Active Airborne Virus Deactivated Decomposed Antibody Extraction Technique Antigen 100% 0.01% Hen Egg Through immunization process, a healthy hen is injected with antigen to stimulate the production of natural antibodies. Eggs produced by immunized hen also contains antibodies. Virus Removal Rate 60s Centrifugal The egg yolk liquid is removed and by centrifugal separation, pure is obtained. Effective against the common H1N1 and H3N2 Type-A influenza viruses. Neutralization of viruses as a result of natural antigen-antibody reaction. ater Soluble By method of deposition, high concentration of is extracted. After sterilization and spray dry, powder is applied on special moisture-retaining filter material. Power to absorb bacteria and viruses more than DOUBLED! * Titanium Apatite filter is offered as optional accessory. This product is not a medical device, medical treatment device or therapeutic goods. This product is not intended to have any therapeutic use or to be used for the diagnosis, treatment relief or prevention of illness. If you have a health concern or are not feeling well, please consult a health care professional. Turbo Mode TURBO function is available in COOL and HEAT modes. Once it is activated, the air-conditioner will run on full power with indoor fan running at MAX speed for 20 minutes. This enables the set temperature to be achieved faster. If TURBO and SLEEP are activated at the same time, the SLEEP mode timer will be reset, it will resume after TURBO function is cleared. T room Dissolution efficiency is also improved Lower Sound Level ith up to five selectable fan speeds, users are given more choices. By selecting Quiet mode, the sound pressure level can be reduced down to an unobtrusive 25 dba. 25 dba * Bio Antibody filter is offered as optional accessory This product is not a medical device, medical treatment device or therapeutic goods. This product is not intended to have any therapeutic use or to be used for the diagnosis, treatment relief or prevention of illness. If you have a health concern or are not feeling well, please consult a health care professional. T set Start 20min 30min 3 4

Temperature Sleep Mode Once activated, sleep mode ensures a comfortable environment for restful sleep. Depending on the mode, set temperature is increased/decreased gradually according to normal sleeping temperature patterns. all Mounted J and F Series * * * * ** AL GOLD Sleep Set On 0 1/2 1 2 Cooling * Optional ** For R(Y)30DXV1, R(Y)30DXY1 Temperature -1 C Hours +0.5 C +0.5 C +1 C FT10/15/20/25JXV1 R09/15CXV1 R18/25/28CXV1 Heating -2 C 0 1/2 1 Sleep Set On Heating mode* -3 C Cooling mode 2 Hours * Heat pump models only Auto Random Restart with Last-State-Memory In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed). This ensures that air conditioners in the same building resume randomly instead of all units resuming at the same time, preventing power surge after a blackout. Operation Power Failure FT(Y)30FXV1 Stop E 2 PROM Power Failure Setting stored before power failure. Higher cooling/heating capacity wall mounted unit with below key features: Uniform Air Distribution Automated air swing ensures conditioned air are distributed evenly. Restart Quiet Operation Random-pitched fan blade delivers high air flow at lower sound level. Easy Maintenance Air intake grille is easily detachable to be cleaned with water. Compact & Easy-to-Use Handset Prominent 40mm LCD display. Real time clock display. Dedicated buttons for Quiet and Turbo functions. Uniform Air Distribution Quiet Operation Easy Maintenance Stylish Flat-Panel Turbo Mode Lower Sound Level FT30FXV1 Specification for all Mounted - Cooling Only Model Name FT10JXV1 FT15JXV1 FT20JXV1 FT25JXV1 R09CXV1 R15CXV1 R18CXV1 R25CXV1 10000 11800 18000 24000 2930 3458 5280 7030 / 2.99 2.90 3.24 2.78 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 358/342/282/225/209 372/355/298/242/225 594/531/474/422/381 641/614/537/474/418 Sound Pressure Level dba 39/38/32/27/25 41/40/35/29/28 44/42/39/36/35 48/46/43/40/37 Height mm 288 288 310 310 idth mm 800 800 1065 1065 Depth mm 206 206 224 224 Net eight kg 9 9 14 14 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Sound Pressure Level dba 45 49 52 52 Height mm 494 540 651 753 idth mm 600 700 855 855 Depth mm 245 250 328 328 Net eight kg 25 29 43 57 Pipe Connection- Liquid mm 6.35 6.35 6.35 9.52 Pipe Connection- Gas mm 9.52 12.70 15.88 15.88 Specification for all Mounted - Cooling Only Model Name FT30FXV1 FT30FXV1 FT30FXV1 R28CXV1 R30DXV1 R30DXY1 27000 28000 28000 7913 8206 8206 / 3.00 3.19 3.20 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 670/630/550 670/630/500 670/630/500 Sound Pressure Level dba 49/47/45 49/47/45 49/47/45 Height mm 360 360 360 idth mm 1200 1200 1200 Depth mm 200 200 200 Net eight kg 17 17 17 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50 Sound Pressure Level dba 54 58 58 Height mm 753 852 852 idth mm 855 1030 1030 Depth mm 328 400 400 Net eight kg 57 95 95 Pipe Connection- Liquid mm 9.52 9.52 9.52 Pipe Connection- Gas mm 15.88 15.88 15.88 R30DXV1 R30DXY1 5 6

all Mounted J and F Series * * * * ** AL GOLD * Optional ** For R(Y)30DXV1, R(Y)30DXY1 Ceiling Cassette E Series 9 FTY09/15/20/25JXV1 RY09/15CXV1 RY20/25/28CXV1 FTY30FXV1 Uniform Air Distribution Quiet Operation Easy Maintenance Stylish Flat-Panel Turbo Mode Lower Sound Level RY30DXV1 Ceiling Cassette C Series 12 Specification for all Mounted - Heatpump FTY09JXV1 FTY15JXV1 FTY20JXV1 RY09CXV1 RY15CXV1 RY20CXV1 8400 11800 19500 2462 3458 5720 9000 13000 19500 2642 3810 5720 / 2.66 2.90 3.09 / 3.52 3.58 3.27 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 332/315/269/225/209 372/255/298/242/225 570/536/478/424/375 Sound Pressure Level dba 36/34/32/29/28 41/40/35/29/28 44/42/39/36/35 Height mm 288 288 310 idth mm 800 800 1065 Depth mm 206 206 224 Net eight kg 9 9 14 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Sound Pressure Level dba 46 49 49 Height mm 494 540 651 idth mm 600 700 855 Depth mm 245 250 328 Net eight kg 26 30 47 Pipe Connection- Liquid mm 6.35 6.35 6.35 Pipe Connection- Gas mm 9.52 12.70 15.88 Model Name FTY25JXV1 RY25CXV1 24000 7030 25000 7330 2.78 2.97 220-240/1/50 641/614/537/474/418 48/46/43/40/37 310 1065 224 14 220-240/1/50 52 753 855 328 57 9.52 15.88 Ceiling Convertible E Series Ceiling Concealed C Series 15 19 Specification for all Mounted - Heatpump Model Name Power Supply Air Flow Sound Pressure Level Height idth Depth Net eight Power Supply Sound Pressure Level Height idth Depth Net eight Pipe Connection- Liquid Pipe Connection- Gas / / V/Ph/Hz CFM dba mm mm mm kg V/Ph/Hz dba mm mm mm kg mm mm FTY30FXV1 FTY30FXV1 RY28CXV1 RY30DXV1 27000 30000 7913 8790 27000 30000 7913 8790 2.99 2.94 3.04 3.07 220-240/1/50 220-240/1/50 670/630/500 670/630/500 49/47/45 49/47/45 360 360 1200 1200 200 200 17 17 220-240/1/50 220-240/1/50 54 58 753 852 855 1030 328 400 57 95 9.52 9.52 15.88 15.88 Light Commercial Series 7 8

Optimum Air Discharge Combining 4 ways air discharge and large discharge area on each side, Ceiling Cassette promote even air distribution. The additional feature of automatic air swing helps to distribute the conditioned air more evenly to every corner of the room. Fresh Air Option Knock out hole is available at the unit. Installation & accessories need to be field supplied & installed. Keep the introduction of fresh air intake within 20% of total air flow. Also provide a chamber and use a booster fan. Superior Sound Level The FH(Y)C-EXV1 series is equipped with a newly-developed turbo fan; the shape produce low air turbulence. ith up to 4 selected fan speeds, users are given more choices. By selecting the Quiet mode, the sound pressure level can be as low as 28dBA. Model FH(Y)C20EXV1 FH(Y)C25EXV1 FH(Y)C28EXV1 FH(Y)C40EXV1 FH(Y)C50EXV1 Max (dba) 34 37 42 47 49 Min (dba) 28 32 33 36 39 Modern & Elegant Panel It is designed with unique "round" side contour and new LED light location. Rotatable intake grill promotes uniform installation. Allow 90 Rotation Multi-Comfort 3 Air Swing Pattern Control To increase the comfort level of the air conditioned area of FH(Y)C-EXV1 series, the system is built in with 3 different types of air flow pattern to suit different requirement. Ceiling Cassette E Series 35 75 Pattern 1 Standard Setting For gentle drafts. Low Height Model The FH(Y)C-EXV1 series height is as low as 300mm to ease installation. 75 35 35 50 Pattern 2 Draft Prevention Setting Select this setting to eliminate direct drafts which can lead to discomfort. 50 35 55 A B 75 Pattern 3 Setting to Prevent Soiling of Ceiling Recommended for location with light colour ceiling that must be kept spotless. The default setting for air swing pattern is pattern 1. The air swing pattern can be selected through the wireless remote control. 75 55 Dimension (mm) Model A B FH(Y)C20 ~ 28EXV1 265 300 FH(Y)C40 ~ 50EXV1 300 335 FH(Y)C20/25/28/40/50EXV1 Built-In High Head Drain Pump The unit comes with a built-in high head drain pump of 700mm pressure head. A safety float is incorporated in the drain pump to monitor its water level. 700mm 9 10

Ceiling Cassette E Series AL GOLD * * ** * Optional ** For R(Y)35/40DXV1, R(Y)40/50DXY1 FH(Y)C20/25/28/40/50EXV1 R(Y)20/25/28CXV1 R(Y)35/40DXV1 R(Y)40/50DXY1 Optimum Air Discharge Modern & Elegant Panel Superior Sound Level Multi-Comfort 3 Air Swing Pattern Control Low Height Model Built-In High Head Drain Pump Specification for Ceiling Cassette- E Series, 3ft x 3ft Panel, Cooling Only Model Name FHC20EXV1 FHC25EXV1 FHC28EXV1 FHC40EXV1 FHC40EXV1 FHC40EXV1 FHC50EXV1 R20CXV1 R25CXV1 R28CXV1 R35DXV1 R40DXV1 R40DXY1 R50DXY1 19500 25000 27000 35000 39000 39500 49500 5715 7327 7913 10258 11430 11600 14500 / 2.92 2.88 2.91 3.41 3.31 3.17 3.15 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 600/530/430/400 680/600/530/430 860/725/620/530 1030/860/740/620 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 34/32/30/28 37/34/33/32 42/38/35/33 47/44/40/36 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 265 [340] 265 [340] 265 [340] 300 [375] 300 [375] 300 [375] 300 [375] idth [with Panel] mm 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] Depth [with Panel] mm 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] Net eight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 51 52 58 58 58 58 58 Height mm 651 753 753 852 852 852 852 idth mm 855 855 855 1030 1030 1030 1030 Depth mm 328 328 328 400 400 400 400 Net eight kg 47 57 57 95 100 100 105 Pipe Connection- Liquid mm 6.35 9.52 9.52 9.52 9.52 9.52 9.52 Pipe Connection- Gas mm 15.88 15.88 15.88 19.05 19.05 19.05 19.05 Specification for Ceiling Cassette- E Series, 3ft x 3ft Panel, Heatpump Model Name FHYC20EXV1 FHYC25EXV1 FHYC28EXV1 FHYC40EXV1 FHYC40EXV1 FHYC40EXV1 FHYC50EXV1 RY20CXV1 RY25CXV1 RY28CXV1 RY35DXV1 RY40DXV1 RY40DXY1 RY50DXY1 19500 19500 25000 25000 27000 28000 35000 35000 39500 42000 39500 42000 48000 50000 5715 5715 7327 7327 7913 8206 10258 10258 11600 12300 11600 12300 14100 14700 / 2.92 2.88 2.91 3.41 3.22 3.31 2.93 / 3.38 3.17 3.49 3.73 3.79 3.85 3.49 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 600/530/430/400 680/600/530/430 860/725/620/530 1030/860/740/620 1030/860/740/620 1030/860/740/620 1200/1030/930/780 Sound Pressure Level dba 34/32/30/28 37/34/33/32 42/38/35/33 47/44/40/36 47/44/40/36 47/44/40/36 49/45/43/39 Height [with Panel] mm 265 [340] 265 [340] 265 [340] 300 [375] 300 [375] 300 [375] 300 [375] idth [with Panel] mm 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] Depth [with Panel] mm 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] 820 [990] Net eight [with Panel] kg 26 [30] 28 [32] 31 [35] 39 [43] 39 [43] 39 [43] 41 [45] Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 51 52 58 58 58 58 58 Height mm 651 753 753 852 852 852 852 idth mm 855 855 855 1030 1030 1030 1030 Depth mm 328 328 328 400 400 400 400 Net eight kg 47 57 57 95 100 100 105 Pipe Connection- Liquid mm 6.35 9.52 9.52 9.52 9.52 9.52 9.52 Pipe Connection- Gas mm 15.88 15.88 15.88 19.05 19.05 19.05 19.05 Ceiling Cassette C Series FF(Y)10/15/20CXV1

4 ay Air Discharge And Air Swing It comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room. Fresh Air Option Knock out hole is available at the unit. Installation & accessories need to be field supplied & installed. Keep the introduction of fresh air intake within 20% of total air flow. Also provide a chamber and use a booster fan. Ceiling Cassette C Series AL * * GOLD * Optional FF(Y)10/15/20CXV1 R(Y)10/15CXV1 R(Y)18/20CXV1 4 ay Air Discharge And Air Swing Compact Design Built-In High Head Drain Pump Stylish And Slim Panel Auto Mode Hot Keep Cycle Self Diagnosis Compact Design The Ceiling Cassette C series is designed to be compact. Its body dimension is only 570mm x 570mm which can easily fit into a 600mm ceiling grids. This make installation a lot easier. Ceiling panel T bar 600 mm Stylish And Slim Panel The slim panel can be blended easily into interior decoration and design. Built-In High Head Drain Pump The unit comes with a built-in high head drain pump of 700mm pressure head. A safety float is incorporated in the drain pump to monitor its water level. 700mm Specification for Ceiling Cassette- C Series, 2ft x 2ft Panel, Cooling Only Model Name FF10CXV1 FF15CXV1 FF20CXV1 R10CXV1 R15CXV1 R20CXV1 9500 12500 19000 2780 3663 5570 / 3.03 3.04 3.04 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 410/360/330 410/360/330 450/410/340 Sound Pressure Level dba 41/38/35 41/38/34 44/41/37 Height [with Panel] mm 250 [295] 250 [295] 250 [295] idth [with Panel] mm 570 [640] 570 [640] 570 [640] Depth [with Panel] mm 570 [640] 570 [640] 570 [640] Net eight [with Panel] kg 22 [24] 23 [25] 23 [25] Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Sound Pressure Level dba 46 49 51 Height mm 540 540 651 idth mm 700 700 855 Depth mm 250 250 328 Net eight kg 28 28 47 Pipe Connection- Liquid mm 6.35 6.35 6.35 Pipe Connection- Gas mm 9.52 12.70 15.88 Auto Mode Auto Mode allows the setting to change automatically between cool and heat mode depending on the room temperature and the set temperature required. Hot Keep Cycle During heat mode hot keep cycle, the fan will run at low speed during the thermostat cycle off. As a result, one will not feel the draft of cold air discharge from the unit. Option of fan stop or fan run at specific interval timing can also be selected. Self Diagnosis This intelligent feature helps to detect faults or malfunctioning in the system and give user a warning by blinking of the LED lights. Specification for Ceiling Cassette- C Series, 2ft x 2ft Panel, Heatpump Model Name FFY10CXV1 FFY15CXV1 FFY20CXV1 FFY20CXV1 RY10CXV1 RY15CXV1 RY18CXV1 RY20CXV1 9500 9500 12500 12500 18000 18400 19000 19500 2780 2780 3660 3660 5280 5390 5570 5720 / 3.03 3.04 2.87 3.04 / 3.40 3.47 3.21 3.21 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 410/360/330 410/360/330 450/410/340 450/410/340 Sound Pressure Level dba 41/38/35 41/38/34 44/41/37 44/41/37 Height [with Panel] mm 250 [295] 250 [295] 250 [295] 250 [295] idth [with Panel] mm 570 [640] 570 [640] 570 [640] 570 [640] Depth [with Panel] mm 570 [640] 570 [640] 570 [640] 570 [640] Net eight [with Panel] kg 22 [24] 23 [25] 23 [25] 23 [25] Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Sound Pressure Level dba 46 49 51 51 Height mm 540 540 651 651 idth mm 700 700 855 855 Depth mm 250 250 328 328 Net eight kg 30 30 43 47 Pipe Connection- Liquid mm 6.35 6.35 6.35 6.35 Pipe Connection- Gas mm 9.52 12.70 15.88 15.88

Ceiling and Floor Installation Option The unit is designed with the option to install either below the ceiling or mounted at low wall position to suit any interior design requirement. *all bracket is supplied as optional item. Automatic Air Swing The motorized louver enables the air flow to be evenly distributed. At the same time, negative ion will be released to provide quality air. Flexible Installation The unit is designed to work with high pressure head drain pump (optional). Thus offering flexibility for installation of condensate drain pipe. The high pressure head drain pump is incorporated with a float switch as safety protection. 700mm *Drain pump kit supplied as optional item. Auto Random Restart with Last-State-Memory In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed). This ensures that air conditioners in the same building resume randomly instead of all units resuming at the same time, preventing power surge after a blackout. Operation Power Failure Power Failure Stop E 2 PROM Setting stored before power failure. Restart Ceiling Convertible E Series Better Serviceability The washable filter can be easily accessed by just pulling down the intake grill. During servicing or repairing, only the bottom panel is needed to be removed in order to access the parts as below. Fan Motor Blower iring Connection Control Box Piping Connection FL(Y)15/20/25/28/35/40/50EXV1

Ceiling Covertible E Series Ceiling Covertible E Series * * ** AL GOLD AL GOLD * ** * Optional ** For R30/35/40DXV1, R40/50/61DXY1 * Optional ** For RY30/35/40DXV1, RY40/50/61DXY1 FL15/20/25/28/35/40/50EXV1 FH62CXV1 R15CXV1 R20/25/28CXV1 R30/35/40DXV1 R40/50/61DXY1 FLY15/20/25/28/35/40/50EXV1 FHY62CXV1 RY15CXV1 RY18/20/25/28CXV1 RY30/35/40DXV1 RY40/50/61DXY1 Ceiling and Floor Installation Option Automatic Air Swing Flexible Installation Auto Random Restart with Last-State-Memory Better Serviceability Ceiling and Floor Installation Option Automatic Air Swing Flexible Installation Auto Random Restart with Last-State-Memory Better Serviceability Specification for Ceiling Convertible & Ceiling Exposed - Cooling Only Model Name FL15EXV1 FL20EXV1 FL25EXV1 FL28EXV1 FL28EXV1 R15CXV1 R20CXV1 R25CXV1 R28CXV1 R30DXV1 12000 19000 24000 28000 28000 3520 5570 7030 8210 8210 / 2.73 2.99 2.73 2.94 3.02 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 508/386/350 520/460/406 580/530/490 640/560/460 640/560/460 Sound Pressure Level dba 48/43/41 48/46/43 50/47/46 56/51/44 56/51/44 Height mm 218 218 218 218 218 idth mm 1080 1080 1080 1080 1080 Depth mm 630 630 630 630 630 Net eight kg 26 27 27 28 28 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Sound Pressure Level dba 49 51 52 58 58 Height mm 540 651 753 753 852 idth mm 700 855 855 855 1030 Depth mm 250 328 328 328 400 Net eight kg 28 47 57 57 95 Pipe Connection- Liquid mm 6.35 6.35 9.52 9.52 9.52 Pipe Connection- Gas mm 12.70 15.88 15.88 15.88 15.88 Specification for Ceiling Convertible & Ceiling Exposed - Heatpump Model Name FLY15EXV1 FLY20EXV1 FLY20EXV1 FLY25EXV1 FLY28EXV1 FLY28EXV1 RY15CXV1 RY18CXV1 RY20CXV1 RY25CXV1 RY28CXV1 RY30DXV1 12000 12000 18000 18500 19000 19500 24000 25000 28000 28500 28000 28500 3520 3520 5280 5420 5570 5720 7030 7330 8210 8350 8210 8350 / 2.73 2.82 2.99 2.73 2.94 3.02 / 3.52 3.17 3.16 2.94 3.54 2.86 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 508/386/350 520/460/406 520/460/406 580/530/490 640/560/460 640/560/460 Sound Pressure Level dba 48/43/41 48/46/43 48/46/43 50/47/46 56/51/44 56/51/44 Height mm 218 218 218 218 218 218 idth mm 1080 1080 1080 1080 1080 1080 Depth mm 630 630 630 630 630 630 Net eight kg 26 27 27 27 28 28 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Sound Pressure Level dba 49 51 51 52 58 58 Height mm 540 651 651 753 753 852 idth mm 700 855 855 855 855 1030 Depth mm 250 328 328 328 328 400 Net eight kg 30 43 47 57 57 95 Pipe Connection- Liquid mm 6.35 6.35 6.35 9.52 9.52 9.52 Pipe Connection- Gas mm 12.70 15.88 15.88 15.88 15.88 15.88 Model Name FL35EXV1 FL40EXV1 FL40EXV1 FL50EXV1 FH62CXV1 R35DXV1 R40DXV1 R40DXY1 R50DXY1 R61DXY1 33500 37000 38000 47500 56000 9800 10800 11140 13900 16410 / 3.32 2.85 2.93 2.76 2.93 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 840/753/669 1100/983/877 1100/983/877 1215/1082/959 1550/1320/1000 Sound Pressure Level dba 49/48/46 53/48/48 53/48/48 52/50/49 56/53/46 Height mm 260 260 260 260 285 idth mm 1320 1538 1538 1786 1903 Depth mm 634 634 634 634 680 Net eight kg 38 45 45 58 85 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 58 61 Height mm 852 852 852 852 852 idth mm 1030 1030 1030 1030 1030 Depth mm 400 400 400 400 400 Net eight kg 95 100 100 105 108 Pipe Connection- Liquid mm 9.52 9.52 9.52 9.52 12.70 Pipe Connection- Gas mm 19.05 19.05 19.05 19.05 19.05 17 Model Name FLY35EXV1 FLY40EXV1 FLY40EXV1 FLY50EXV1 FHY62CXV1 RY35DXV1 RY40DXV1 RY40DXY1 RY50DXY1 RY61DXY1 33500 38000 37500 43000 38000 42000 46000 52000 56000 56000 9800 11100 11000 12600 11100 12300 13500 15200 16410 16410 / 3.32 3.05 3.23 2.84 2.93 / 3.20 3.60 3.28 3.67 3.61 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 840/753/669 1100/983/877 1100/983/877 1215/1082/959 1550/1320/1000 Sound Pressure Level dba 49/48/46 53/48/48 53/48/48 52/50/49 56/53/46 Height mm 260 260 260 260 285 idth mm 1320 1538 1538 1786 1903 Depth mm 634 634 634 634 680 Net eight kg 38 45 45 58 85 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 58 61 Height mm 852 852 852 852 852 idth mm 1030 1030 1030 1030 1030 Depth mm 400 400 400 400 400 Net eight kg 95 100 100 105 108 Pipe Connection- Liquid mm 9.52 9.52 9.52 9.52 12.70 Pipe Connection- Gas mm 19.05 19.05 19.05 19.05 19.05 18

Excellent Air Distribution The conditioned air can be distributed evenly to every corner of the room through ducting. This helps to create a pleasant environment and maintain comfort. Furthermore, multiple area can be conditioned simultaneously by using just one indoor unit. Auto Random Restart with Last-State-Memory In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed). This ensures that air conditioners in the same building resume randomly instead of all units resuming at the same time, preventing power surge after a blackout. Power Failure Power Failure Operation Stop Restart E 2 PROM Setting stored before power failure. Ceiling Concealed C Series Double Protection Drainage System The primary drain pan is designed with high thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan built in to the standard unit offers extra protection against possible water leaking problems. Primary Drain Pan Polysterene (Ps) ith Height Impact Polystyrene (Hips) Cover Secondary Drain Pan ith Insulation FD(Y)B10/15/20/25/30/40/50/60CXV1 FD(Y)M10/15/20/25/28/30/38/40/50/60CXV1 Flexibility In System Design The unit offers fan motor that can operate up to 4 speeds, thus provide choices of external static pressure for designing ducting system. In addition, a range of FD(Y)B-CXV1 model with optional specification of low external static pressure is also provided. Please refer to the technical specification. Self Diagnosis Features The microprocessor provides the possibility to detect and to diagnose any faults that occurs in the system. Faults are displayed as error code in the wired controller. This will ease the troubleshooting process. 19 20

Ceiling Concealed C Series Ceiling Concealed C Series * ** * ** AL GOLD AL GOLD * Optional ** For R30/35/40DXV1, R40/50/61DXY1 * Optional ** For RY30/35/40DXV1, RY40/50/61DXY1 FDB10/15/20/25/30/40/50/60CXV1 R10/15CXV1 R20/25/28CXV1 R30/35/40DXV1 R30/40/50/61DXY1 Excellent Air Distribution Auto Random Restart with Last-State-Memory Double Protection Drainage System Flexibility In System Design Self Diagnosis Features FDYB10/15/20/25/30/40/50/60CXV1 RY10/15CXV1 RY18/20/25/28CXV1 RY30/35/40DXV1 RY30/40/50/61DXY1 Excellent Air Distribution Auto Random Restart with Last-State-Memory Double Protection Drainage System Flexibility In System Design Self Diagnosis Features Specification for Ceiling Concealed, Low Static - Cooling Only Model Name FDB10CXV1 FDB15CXV1 FDB20CXV1 FDB25CXV1 R10CXV1 R15CXV1 R20CXV1 R25CXV1 9500 12300 19000 23500 2780 3600 5570 6890 / 3.15 2.91 3.01 2.69 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 300/285/260 510/490/400 700/675/640 730/660/580 External Static Pressure Pa 10/8/5 10/8/5 20/19/15 20/18/11 Sound Pressure Level dba 33/30/25 36/33/28 38/37/35 40/39/35 Height mm 261 261 261 261 idth mm 765 905 1065 1200 Depth mm 411 411 411 411 Net eight kg 17 21 22 25 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Sound Pressure Level dba 46 49 51 52 Height mm 540 540 651 753 idth mm 700 700 855 855 Depth mm 250 250 328 328 Net eight kg 28 28 47 57 Pipe Connection- Liquid mm 6.35 6.35 6.35 9.52 Pipe Connection- Gas mm 9.52 12.70 15.88 15.88 Model Name FDB30CXV1 FDB30CXV1 FDB30CXV1 FDB40CXV1 R28CXV1 R30DXV1 R30DXY1 R35DXV1 28000 29000 29000 33500 8206 8499 8499 9818 / 2.67 3.13 3.06 2.99 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 900/830/760/710 900/830/760/710 900/830/760/710 1100/1060/990/900 External Static Pressure Pa 49/39/29/20 49/39/29/20 49/39/29/20 49/39/29/20 Sound Pressure Level dba 41/40/39/36 41/40/39/36 41/40/39/36 43/41/40/38 Height mm 378 378 378 378 idth mm 929 929 929 1045 Depth mm 541 541 541 541 Net eight kg 39 39 39 42 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50 220-240/1/50 Sound Pressure Level dba 58 58 58 58 Height mm 753 852 852 852 idth mm 855 1030 1030 1030 Depth mm 328 400 400 400 Net eight kg 57 95 95 95 Pipe Connection- Liquid mm 9.52 9.52 9.52 9.52 Pipe Connection- Gas mm 15.88 15.88 15.88 19.05 Model Name FDB40CXV1 FDB40CXV1 FDB50CXV1 FDB60CXV1 R40DXV1 R40DXY1 R50DXY1 R61DXY1 38000 38000 48000 56000 11140 11140 14100 16410 / 3.24 2.91 2.97 2.89 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 1100/1060/990/900 1100/1060/990/900 1590/1380/1280/1210 1650/1530/1430/1290 External Static Pressure Pa 49/39/29/20 49/39/29/20 78/59/39/20 69/49/29/20 Sound Pressure Level dba 43/41/40/38 43/41/40/38 46/44/43/42 48/47/46/45 Height mm 378 378 378 378 idth mm 1045 1045 1299 1499 Depth mm 541 541 541 541 Net eight kg 42 42 54 62 Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 61 Height mm 852 852 852 852 idth mm 1030 1030 1030 1030 Depth mm 400 400 400 400 Net eight kg 100 100 105 108 Pipe Connection- Liquid mm 9.52 9.52 9.52 12.70 Pipe Connection- Gas mm 19.05 19.05 19.05 19.05 Specification for Ceiling Concealed, Low Static - Heatpump Model Name FDYB10CXV1 FDYB15CXV1 FDYB20CXV1 FDYB20CXV1 RY10CXV1 RY15CXV1 RY18CXV1 RY20CXV1 9500 12300 18000 19000 2780 3600 5280 5570 9500 12000 18500 19800 2780 3515 5420 5800 / 3.15 2.91 2.83 3.01 / 3.59 3.40 3.18 3.23 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 300/285/260 510/490/400 700/675/640 700/675/640 External Static Pressure Pa 10/8/5 10/8/5 20/19/15 20/19/15 Sound Pressure Level dba 33/30/25 36/33/28 38/37/35 38/37/35 Height mm 261 261 261 261 idth mm 765 905 1065 1065 Depth mm 411 411 411 411 Net eight kg 17 21 22 22 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Sound Pressure Level dba 46 49 51 51 Height mm 540 540 651 651 idth mm 700 700 855 855 Depth mm 250 250 328 328 Net eight kg 30 30 43 47 Pipe Connection- Liquid mm 6.35 6.35 6.35 6.35 Pipe Connection- Gas mm 9.52 12.70 15.88 15.88 Model Name FDYB25CXV1 FDYB30CXV1 FDYB30CXV1 FDYB30CXV1 RY25CXV1 RY28CXV1 RY30DXV1 RY30DXY1 23500 28000 30000 30000 6890 8602 8792 8792 24000 29000 30000 30000 7030 8499 8792 8792 / 2.69 2.67 2.87 2.89 / 2.84 3.21 2.90 2.92 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 730/660/580 900/830/760/710 900/830/760/710 900/830/760/710 External Static Pressure Pa 20/18/11 49/39/29/20 49/39/29/20 49/39/29/20 Sound Pressure Level dba 40/39/35 41/40/39/36 41/40/39/36 41/40/39/36 Height mm 261 378 378 378 idth mm 1200 929 929 929 Depth mm 411 541 541 541 Net eight kg 25 39 39 39 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 Sound Pressure Level dba 52 58 58 58 Height mm 753 753 852 852 idth mm 855 855 1030 1030 Depth mm 328 328 400 400 Net eight kg 57 57 95 95 Pipe Connection- Liquid mm 9.52 9.52 9.52 9.52 Pipe Connection- Gas mm 15.88 15.88 15.88 15.88 Model Name FDYB40CXV1 FDYB40CXV1 FDYB40CXV1 FDYB50CXV1 FDYB60CXV1 RY35DXV1 RY40DXV1 RY40DXY1 RY50DXY1 RY61DXY1 33500 37500 37500 48000 56000 9818 11000 11000 14100 16410 35000 40000 40000 50000 56000 10257 11700 11700 14700 16410 / 3.12 3.02 3.07 2.84 2.85 / 3.26 3.27 3.36 3.40 3.46 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 1100/1060/990/900 1100/1060/990/900 1100/1060/990/900 1590/1380/1280/1210 1650/1530/1430/1290 External Static Pressure Pa 49/39/29/20 49/39/29/20 49/39/29/20 78/59/39/20 69/49/29/20 Sound Pressure Level dba 43/41/40/38 43/41/40/38 43/41/40/38 46/44/43/42 48/47/46/45 Height mm 378 378 378 378 378 idth mm 1045 1045 1045 1299 1499 Depth mm 541 541 541 541 541 Net eight kg 42 42 42 54 62 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 58 61 Height mm 852 852 852 852 852 idth mm 1030 1030 1030 1030 1030 Depth mm 400 400 400 400 400 Net eight kg 95 100 100 105 108 Pipe Connection- Liquid mm 9.52 9.52 9.52 9.52 12.70 Pipe Connection- Gas mm 19.05 19.05 19.05 19.05 19.05 21 22

Ceiling Concealed C Series Ceiling Concealed C Series * ** * ** AL GOLD AL GOLD * Optional ** For R30/35/40DXV1, R40/50/61DXY1 * Optional ** For RY30/35/40DXV1, RY40/50/61DXY1 FDM10/15/20/25/28/30/38/40/50/60CXV1 R10/15CXV1 R20/25/28CXV1 R30/35/40DXV1 R30/40/50/61DXY1 FDYM10/15/20/25/28/30/38/40/50/60CXV1 RY10/15CXV1 RY18/20/25/28CXV1 RY30/35/40DXV1 RY30/40/50/61DXY1 Excellent Air Distribution Auto Random Restart with Last-State-Memory Double Protection Drainage System Flexibility In System Design Self Diagnosis Features Excellent Air Distribution Auto Random Restart with Last-State-Memory Double Protection Drainage System Flexibility In System Design Self Diagnosis Features Specification for Ceiling Concealed, Standard Static - Cooling Only Model Name FDM10CXV1 FDM15CXV1 FDM20CXV1 FDM25CXV1 FDM28CXV1 FDM28CXV1 R10CXV1 R15CXV1 R20CXV1 R25CXV1 R28CXV1 R30DXV1 9500 12300 19000 23500 27000 28000 2780 3600 5570 6890 7913 8206 / 3.17 2.94 3.05 2.69 2.64 3.01 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 300/285/260 510/490/400 700/675/640 730/660/580 850/810/770/710 850/810/770/710 External Static Pressure Pa 49/44/36 49/42/28 49/45/41 49/43/30 98/78/68/59 98/78/68/59 Sound Pressure Level dba 36/35/33 40/38/33 42/41/40 41/40/36 44/41/38/34 44/41/38/34 Height mm 261 261 261 261 285 285 idth mm 765 905 1065 1200 1007 1007 Depth mm 411 411 411 411 600 600 Net eight kg 17 21 22 25 38 38 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Sound Pressure Level dba 46 49 51 52 58 58 Height mm 540 540 651 753 753 852 idth mm 700 700 855 855 855 1030 Depth mm 250 250 328 328 328 400 Net eight kg 28 28 47 57 57 95 Pipe Connection- Liquid mm 6.35 6.35 6.35 9.52 9.52 9.52 Pipe Connection- Gas mm 9.62 12.70 15.88 15.88 15.88 15.88 Specification for Ceiling Concealed, Standard Static - Heatpump Model Name FDYM10CXV1 FDYM15CXV1 FDYM20CXV1 FDYM20CXV1 FDYM25CXV1 FDYM28CXV1 RY10CXV1 RY15CXV1 RY18CXV1 RY20CXV1 RY25CXV1 RY28CXV1 9500 12300 18000 19000 23500 27000 2780 3600 5280 5570 6890 7913 9500 12000 18500 19800 24000 28000 2780 3515 5420 5800 7030 8206 / 3.17 2.94 2.87 3.05 2.69 2.64 / 3.63 3.44 3.23 3.27 2.83 3.23 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 300/285/260 510/490/400 700/675/640 700/675/640 730/660/580 850/810/770/710 External Static Pressure Pa 49/44/36 49/42/28 49/45/41 49/45/41 49/43/30 98/78/68/59 Sound Pressure Level dba 36/35/33 40/38/33 42/41/40 42/41/40 41/40/36 44/41/38/34 Height mm 261 261 261 261 261 285 idth mm 765 905 1065 1065 1200 1007 Depth mm 411 411 411 411 411 600 Net eight kg 17 21 22 22 25 38 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Sound Pressure Level dba 46 49 51 51 52 58 Height mm 540 540 651 651 753 753 idth mm 700 700 855 855 855 855 Depth mm 250 250 328 328 328 328 Net eight kg 30 30 43 47 57 57 Pipe Connection- Liquid mm 6.35 6.35 6.35 6.35 9.52 9.52 Pipe Connection- Gas mm 9.52 12.70 15.88 15.88 15.88 15.88 Model Name FDM30CXV1 FDM30CXV1 FDM30CXV1 FDM38CXV1 FDM38CXV1 FDM38CXV1 R28CXV1 R30DXV1 R30DXY1 R35DXV1 R40DXV1 R40DXY1 28000 29000 29000 35000 38000 38000 8206 8499 8499 10257 11137 11137 / 2.80 3.29 3.22 3.23 3.24 3.29 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 900/830/760/710 900/830/760/710 900/830/760/710 1540/1470/1420/1350 1540/1470/1420/1350 1540/1470/1420/1350 External Static Pressure Pa 206/167/127/88 206/167/127/88 206/167/127/88 137/118/108/88 137/118/108/88 137/118/108/88 Sound Pressure Level dba 49/46/42/38 49/46/42/38 49/46/42/38 55/51/48/45 55/51/48/45 55/51/48/45 Height mm 378 378 378 305 305 305 idth mm 929 929 929 1302 1302 1302 Depth mm 541 541 541 638 638 638 Net eight kg 39 39 39 41 41 41 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50 220-240/1/50 220-240/1/50 380-415/3/50 Sound Pressure Level dba 58 58 58 58 58 58 Height mm 753 852 852 852 852 852 idth mm 855 1030 1030 1030 1030 1030 Depth mm 328 400 400 400 400 400 Net eight kg 57 95 95 95 100 100 Pipe Connection- Liquid mm 9.52 9.52 9.52 9.52 9.52 9.52 Pipe Connection- Gas mm 15.88 15.88 15.88 19.05 19.05 19.05 Model Name FDYM28CXV1 FDYM28CXV1 FDYM30CXV1 FDYM30CXV1 FDYM30CXV1 FDYM38CXV1 RY30DXV1 RY30DXY1 RY28CXV1 RY30DXV1 RY30DXY1 RY35DXV1 30000 30000 28000 30000 30000 35000 8792 8792 8602 8792 8792 10257 30000 30000 29000 30000 30000 36000 8792 8792 8499 8792 8792 10550 / 2.94 2.96 2.80 3.00 3.02 3.11 / 2.97 2.99 3.38 3.03 3.06 3.48 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 850/810/770/710 850/810/770/710 900/830/760/710 900/830/760/710 900/830/760/710 1540/1470/1420/1350 External Static Pressure Pa 98/78/68/59 98/78/68/59 206/167/127/88 206/167/127/88 206/167/127/88 137/118/108/88 Sound Pressure Level dba 44/41/38/34 44/41/38/34 49/46/42/38 49/46/42/38 49/46/42/38 55/51/48/45 Height mm 285 285 378 378 378 305 idth mm 1007 1007 929 929 929 1302 Depth mm 600 600 541 541 541 638 Net eight kg 38 38 39 39 39 41 Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 220-240/1/50 220-240/1/50 380-415/3/50 220-240/1/50 Sound Pressure Level dba 58 58 58 58 58 58 Height mm 852 852 753 852 852 852 idth mm 1030 1030 855 1030 1030 1030 Depth mm 400 400 328 400 400 400 Net eight kg 95 95 57 95 95 95 Pipe Connection- Liquid mm 9.52 9.52 9.52 9.52 9.52 9.52 Pipe Connection- Gas mm 15.88 15.88 15.88 15.88 15.88 19.05 Model Name FDM40CXV1 FDM40CXV1 FDM50CXV1 FDM60CXV1 R40DXV1 R40DXY1 R50DXY1 R61DXY1 38000 38000 48000 56000 11140 11140 14100 16410 / 3.42 2.97 3.05 2.91 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 1100/1060/990/900 1100/1060/990/900 1590/1380/1280/1210 1650/1530/1430/1290 External Static Pressure Pa 206/176/127/93 206/176/127/93 176/157/137/108 176/157/137/98 Sound Pressure Level dba 51/49/45/41 51/49/45/41 53/52/50/47 55/53/50/47 Height mm 378 378 378 378 idth mm 1045 1045 1299 1499 Depth mm 541 541 541 541 Net eight kg 42 42 54 62 Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 61 Height mm 852 852 852 852 idth mm 1030 1030 1030 1030 Depth mm 400 400 400 400 Net eight kg 100 100 105 108 Pipe Connection- Liquid mm 9.52 9.52 9.52 12.70 Pipe Connection- Gas mm 19.05 19.05 19.05 19.05 Model Name FDYM38CXV1 FDYM38CXV1 FDYM40CXV1 FDYM40CXV1 FDYM40CXV1 FDYM50CXV1 FDYM60CXV1 RY40DXV1 RY40DXY1 RY35DXV1 RY40DXV1 RY40DXY1 RY50DXY1 RY61DXY1 37000 38000 33500 37500 37500 48000 56000 10800 11100 9818 11000 11000 14100 16410 40000 41000 35000 40000 40000 50000 56000 11700 12000 10257 11700 11700 14700 16410 / 3.03 3.20 3.30 3.13 3.23 2.89 2.91 / 3.42 3.61 3.45 3.44 3.55 3.48 3.57 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 1540/1470/1420/1350 1540/1470/1420/1350 1100/1060/990/900 1100/1060/990/900 1100/1060/990/900 1590/1380/1280/1210 1650/1530/1430/1290 External Static Pressure Pa 137/118/108/88 137/118/108/88 206/176/127/93 206/176/127/93 206/176/127/93 176/157/137/108 176/157/137/98 Sound Pressure Level dba 55/51/48/45 55/51/48/45 51/49/45/41 51/49/45/41 51/49/45/41 53/52/50/47 55/53/50/47 Height mm 305 305 378 378 378 378 378 idth mm 1302 1302 1045 1045 1045 1299 1499 Depth mm 638 638 541 541 541 541 541 Net eight kg 41 41 42 42 42 54 62 Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 58 58 58 58 58 58 61 Height mm 852 852 852 852 852 852 852 idth mm 1030 1030 1030 1030 1030 1030 1030 Depth mm 400 400 400 400 400 400 400 Net eight kg 100 100 95 100 100 105 108 Pipe Connection- Liquid mm 9.52 9.52 9.52 9.52 9.52 9.52 12.70 Pipe Connection- Gas mm 19.05 19.05 19.05 19.05 19.05 19.05 19.05 23 24

Ceiling Concealed D & E Series 28 FD(Y)M75/100DXV1 (High Static) Ducted Split 32 Air-Cooled Rooftop Packaged A-Series 36 FDM75/100EXV1 Air-Cooled Rooftop Packaged C-Series 39 Commercial/ Industrial Series Ceiling Concealed D & E Series 25 26

Ceiling Concealed D & E Series ide External Static Range Cater to different ducting application requirement, FDM-D and FDM-E series are designed with different static range. FDM-D series is designed for very high static requirement (up to 200pa), whereby FDM-E series is for high static requirement (up to 100pa). Both series offer 4 choices of external static pressure by using the built in four speeds direct drive fan motor. As such, selection of desire air flow or external static becomes much easier. Flexible Coupling ide External Static Range Low Height & Compact Design Easy Serviceability Choices Of ired Controller ** AL GOLD ** For FDM75/100DXV1 FDM75/100DXV1 FDM75/100EXV1 R75CXY1 RC100BXY1 RC75/100DXY1 Low Height & Compact Design Both FDM-D and E series offer lower height at 430mm only. Furthermore, depth of FDM-E series had even been reduced 44mm compared to FDM-D series. This gives FDM-E a more compact design. ith this, the unit can be easily fitted into any concealed ceiling and allows more ceiling height space for interior design. 782mm for FDM-E series 826mm for FDM-D series 430mm Easy Serviceability FDM-D is designed to have better serviceability by allowing access to the internal components from side or bottom panel. The entire fan deck can be easily pulled in or out from either side of the unit to ease servicing of fan motor. Bottom access allows servicing of coil and other internal parts of the unit. Return ducting side Choices Of ired Controller BRC51A61/BRC51A62 (Field installed optional accessories) BRC51B62 (Field installed optional accessories) Supply ducting side FDM-D series is supplied standard with BRC51A61/BRC51A62 which offers wide range of control features including 7 days programable timer, 24 hours timer setting, self diagnosis error code display and more. FDM-E series is offered with BRC51B62 as standard. Advanced wired controller BRC51A62 is offered as an option to provide wider range of control features. Specification for Ceiling Concealed D & E Series - Cooling Only Model Name FDM75DXV1 FDM100DXV1 FDM75EXV1 FDM100EXV1 RC75DXY1 RC100DXY1 R75CXY1 RC100BXY1 75000 100000 75000 100000 21780 29310 21680 29310 / 3.02 2.71 2.62 2.78 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Air Flow CFM 2250/1950/1600/1250 3000/2600/2100/1700 2500 3200 External Static Pressure Pa 196/137/98/69 196/137/98/69 100 100 Sound Pressure Level dba 52/52/48/43 55/54/52/48 54 57 Height mm 430 430 430 430 idth mm 1370 1599 1372 1600 Depth mm 710 710 626 626 Net eight kg 92 119 81 88 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 64 64 74 65 Height mm 1041 1041 946 946 idth mm 981 981 1300 939 Depth mm 981 981 500 1116 Net eight kg 170 184 156 175 Pipe connection - Liquid mm 12.70 15.88 12.70 15.88 Pipe connection - Gas mm 25.40 28.58 25.40 28.58

Ceiling Concealed D & E Series AL GOLD FDYM75/100DXV1 RCY75/100EXV1 ide External Static Range Low Height & Compact Design Easy Serviceability Choices Of ired Controller Specification for Ceiling Concealed D & E Series - Heatpump Model Name FDYM75DXV1 FDYM100DXV1 RCY75EXY1 RCY100EXY1 75000 84000 100000 110000 21960 24600 29310 32240 / 2.83 2.87 / 3.30 3.10 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 Air Flow CFM 2250/1950/1600/1250 3000/2600/2100/1700 External Static Pressure Pa 196/137/98/69 196/137/98/69 Sound Pressure Level dba 52/52/48/43 55/54/52/48 Height mm 430 430 idth mm 1370 1599 Depth mm 710 710 Net eight kg 92 119 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 Sound Pressure Level dba 64 64 Height mm 1041 1041 idth mm 981 981 Depth mm 981 981 Net eight kg 170 184 Pipe connection - Liquid mm 12.70 15.88 Pipe connection - Gas mm 25.40 28.58 Ducted Split FD125/150DXY1 FDY125/150EXY1

Cabinet Construction Either indoor or outdoor is coated with weatherproofed electro galvanized mild steel casing, with an epoxy is coated with an epoxy polyester powder costing for severe external conditions. Service Panel is available at the convenience side for both indoor and outdoor. Long Piping Application Standard maximum piping length of Daikin ducted split is up to 35m for Cooling Only model and 45m for heatpump model. However, long piping feature for Cooling Only model can be specified for stringent project requirement. Ducted Split B Series AL GOLD Air Throw Direction Convertible discharge air direction at indoor unit has made it versatile to various architectural designs. (Applicable to size 125 and above only) Changeable Drive Package Non-standard external static pressure & airflow requirement can be sized by changing the factory fitted drive package. (limited for belt drive model only) Easy To Reach Access Valve Discharge line and suction line access valve is accessible without opening the unit casing. Safety Features High Pressure and Low Pressure protection. Compressor & motor current overload protection. Sensor fault indication. Minimum compressor running time to ensure oil return. Phase sequential is used to detect for any wrong phase and phase loss during installation and operation Command Performance Standard units are equipped with microprocessor controller and it is equipped with following functions: Mode selection Temperature Setting Timer (delay timer for BRC51B and real time timer for BRC51C) Error code display FD125/150BXY1 2FD200BXY1 2FG250BXY1 3FG350BXY1 4FG400BXY1 4FG600BXY1 ide range of product Modular combination of single indoor unit to multiple outdoor units Partial loading features for units with more than 2 outdoor units Convertible air discharge Changeable drive package (field supplied) for belt driven models Specification for Ducted Split - B Series - Cooling only Model Name RC100BXY1 FD125BXY1 FD150BXY1 2FD200BXY1 2FG250BXY1 2FG300BXY1 RC125BXY1 RC150CXY1 RC100BXY1 x 2 RC125BXY1 x 2 RC150CXY1 x 2 125000 150000 200000 250000 300000 36640 43960 58620 73270 87925 RC150CXY1 3FG300BXY1 RC100BXY1 x 3 300000 87925 / 2.97 2.71 2.64 2.87 2.64 2.81 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Insulation Fire-resistant Polyethylene is used at every possible condensate panel to prevent all forms of water or moisture penetration. Polyethylene, which is also a type of Closed Cell Foam (CCF) insulation has offered the following advantages: Durable external surface that resists dirt tough and resilient Higher degree of puncture resistance when compared to fiberglass Easily cleaned surface (if necessary) to further resist microbial growth Auto-Random Restart henever unit stop due to power failure during operation unit automatically restarts at last setting condition once the power is resumed. However, the compressors will restart randomly if more than one unit is installed and share the same phase of power. Option is provided to cancel this feature. Air Flow CFM 4200 4600 6400 8000 9000 External Static Pressure Pa 150 150 150 200 200 Sound Pressure Level dba 58 59 61 63 66 Height mm 885 885 885 1231 1231 idth mm 1540 1540 1794 1766 1766 Depth mm 850 850 850 1069 1069 Net eight kg 176 189 220 343 343 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 65 73 65 65 74 Height mm 946 1041 946 946 1041 idth mm 939 939 939 939 939 Depth mm 1116 1116 1116 1116 1116 Net eight kg 175 190 175 175 190 9000 200 66 1231 1766 1069 343 380-415/3/50 65 946 939 1116 175 Refrigeration The outdoor units are come with factory Nitrogen holding charge. Installer will need to charge the HCFC-22 (R-22) refrigerant at site according to the manual recommendation Choices Of ired Controller Pipe Connection- Liquid mm 15.88 15.88 15.88 15.88 15.88 Pipe Connection- Gas mm 34.92 34.92 28.58 34.92 34.92 Model Name 3FG350BXY1 4FG400BXY1 3FG450BXY1 4FG500BXY1 4FG600BXY1 RC100BXY1 + [RC125BXY1] x 2 RC100BXY1 x 4 RC150CXY1 x 3 RC125BXY1 x 4 RC150CXY1 x 4 350000 400000 450000 500000 600000 102580 117230 131890 146540 175850 15.88 28.58 / 2.82 2.84 2.64 2.83 2.61 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Components Expansion device: thermal expansion valves are supplied as standard. Double TXV is used in heatpump model to optimize the performance for both cooling and heating. Compressor: Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimize vibration. Fan: A dynamically balanced forward curved fan with a field changeable pulley package, in order to match the designed supply air requirements. Condenser fan blade: Use of 32 and 36 propeller fan blade has effectively reduce the sound pressure level. BRC51B61/BRC51B62 BRC51B63/BRC51B64 BRC51C61 Air Flow CFM 10500 12000 13500 15000 18000 External Static Pressure Pa 200 200 250 250 300 Sound Pressure Level dba 66 66 68 68 70 Height mm 1486 1486 1486 1486 1918 idth mm 2022 2174 2174 2174 2174 Depth mm 1069 1336 1336 1336 1775 Net eight kg 440 513 564 606 991 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 65 / [65] 65 74 65 74 Height mm 946 / [946] 946 1041 946 1041 idth mm 939 / [939] 939 939 939 939 Depth mm 1116 / [1116] 1116 1116 1116 1116 Net eight kg 175 / [175] 175 190 175 190 Pipe Connection- Liquid mm 15.88 15.88 15.88 15.88 15.88 Pipe Connection- Gas mm 28.58 / 34.92 28.58 34.92 34.92 34.92 31 32

Ducted Split B Series Ducted Split D Series ** AL GOLD AL GOLD ** For FDY75/100BXV1 FDY125CXY1 2FDY150BXY1 2FDY200BXY1 2FGY250BXY1 3FGY350BXY1 4FGY400BXY1 RY75CXY1 RCY100/125BXY1 ide range of product Modular combination of single indoor unit to multiple outdoor units Partial loading features for units with more than 2 outdoor units Convertible air discharge Changeable drive package (field supplied) for belt driven models Selectable fan speed for FDY75/100BXV1 FD125/150DXY1 (2-4)FD200/250/300/ 400/500DXY1 ide range of product Modular combination of single indoor unit to multiple outdoor units Partial loading features for units with more than 2 outdoor units Convertible air discharge Changeable drive package (field supplied) for belt driven models RC75/100/125/150DXY1 Specification for Ducted Split - B Series - Heatpump Model Name FDY75BXV1 FDY100BXV1 FDY125CXY1 2FDY150BXY1 2FDY200BXY1 RY75CXY1 RCY100BXY1 RCY125BXY1 RY75CXY1 x 2 RCY100BXY1 x 2 74000 98800 116000 148000 197600 21690 28960 34000 43400 57913 74000 96500 120000 148000 193000 21690 28280 35170 43400 56565 / 2.55 2.83 2.71 2.54 2.96 / 3.10 2.98 3.23 3.08 3.13 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50 Air Flow CFM 2500 3200 4200 4600 6400 External Static Pressure Pa 100 100 150 150 150 Sound Pressure Level dba 56 57 59 59 61 Height mm 572 572 736 885 885 idth mm 1402 1402 1540 1540 1794 Depth mm 605 605 775 850 850 Net eight kg 92 102 182 190 220 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 74 65 65 74 65 Height mm 946 946 946 946 946 idth mm 1300 939 939 1300 939 Depth mm 500 1116 1116 500 1116 Net eight kg 161 183 188 161 183 Pipe Connection- Liquid mm 12.70 15.88 15.88 12.70 15.88 Pipe Connection- Gas mm 25.40 28.58 34.92 25.40 28.58 Specification for Ducted Split D Series - Cooling Model Name FD125DXY1 FD150DXY1 2FD150DXY1 2FD200DXY1 RC125DXY1 RC150DXY1 RC75DXY1 x 2 RC100DXY1 x 2 125000 150000 150000 200000 36640 43960 43960 58620 / 3.11 2.78 3.16 2.67 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Air Flow CFM 3750 4500 4500 6000 External Static Pressure Pa 150 150 150 150 Sound Pressure Level dba 58 59 59 60 Height mm 710 710 710 821 idth mm 1694 1973 1973 1113 Depth mm 775 775 775 1064 Net eight kg 155 175 175 248 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 66 67 64 64 Height mm 1041 1142 1041 1041 idth mm 1083 1083 981 981 Depth mm 1083 1083 981 981 Net eight kg 197 268 170 184 Pipe Connection- Liquid mm 15.88 15.88 12.70 15.88 Pipe Connection- Gas mm 34.92 34.92 25.40 28.58 Model Name 2FGY250BXY1 3FGY300BXY1 3FGY350BXY1 4FGY400BXY1 4FGY500BXY1 RCY125BXY1 x 2 RCY100BXY1x 3 RCY100BXY1 + [RCY125BXY1] x 2 RCY100BXY1 x 4 RCY125BXY1 x 4 232000 240000 296400 289500 330800 336500 395200 386000 464000 480000 68000 70340 86870 84850 96960 98600 115830 113120 136000 140680 / 2.61 2.92 2.68 2.96 2.58 / 3.10 3.09 3.07 3.13 3.06 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Air Flow CFM 8000 9000 10500 12000 15000 External Static Pressure Pa 200 200 200 200 250 Sound Pressure Level dba 63 66 66 66 68 Height mm 1231 1231 1486 1486 1486 idth mm 1766 1766 2022 2174 2174 Depth mm 1069 1069 1069 1336 1336 Net eight kg 343 343 440 513 606 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 65 65 65 / [65] 65 65 Height mm 946 946 946 / [946] 946 946 idth mm 939 939 939 / [939] 939 939 Depth mm 1116 1116 1116 / [1116] 1116 1116 Net eight kg 188 183 183 / [188] 183 188 Pipe Connection- Liquid mm 15.88 15.88 15.88 15.88 15.88 Pipe Connection- Gas mm 34.92 28.58 28.58 / [34.92] 28.58 34.92 Model Name 2FG250DXY1 2FG300DXY1 4FG400DXY1 4FG500DXY1 RC125DXY1 x 2 RC150DXY1 x 2 RC100DXY1 x 4 RC125DXY1 x 4 250000 300000 400000 500000 73270 87920 117230 146540 / 2.93 2.65 2.65 2.79 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Air Flow CFM 7500 9000 12000 15000 External Static Pressure Pa 200 200 300 450 Sound Pressure Level dba 62 65 66 67 Height mm 922 922 1115 1115 idth mm 1202 1405 1596 1952 Depth mm 1226 1226 1462 1462 Net eight kg 321 394 470 567 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 66 67 64 66 Height mm 1041 1142 1041 1041 idth mm 1083 1083 981 1083 Depth mm 1083 1083 981 1083 Net eight kg 197 268 184 197 Pipe Connection- Liquid mm 15.88 15.88 15.88 15.88 Pipe Connection- Gas mm 34.92 34.92 28.58 34.92 3 34

Ducted Split E Series AL GOLD FDY125/150EXY1 (2-4)FDY200/250/300/350/ 400/450/500/600EXY1 RCY75/100/125/150EXY1 ide range of product Modular combination of single indoor unit to multiple outdoor units Partial loading features for units with more than 2 outdoor units Convertible air discharge Changeable drive package (field supplied) for belt driven models Basic Specification for Ducted Split - E Series Model Name FDY125EXY1 FDY150EXY1 2FDY150EXY1 2FDY200EXY1 2FGY250EXY1 2FGY300EXY1 RCY125EXY1 RCY150EXY1 RCY75EXY1 x 2 RCY100EXY1 x 2 RCY125EXY1 x 2 RCY150EXY1 x 2 116000 150000 154000 192000 232000 300000 34000 43960 45140 56270 68000 87920 130000 160000 170000 212000 260000 320000 38100 46890 49820 62130 76200 93970 / 2.98 2.88 3.03 2.75 2.85 2.82 / 3.57 3.66 3.49 2.98 3.40 3.56 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Air Flow CFM 3750 4500 4500 6400 8000 9000 External Static Pressure Pa 150 150 150 150 200 200 Sound Pressure Level dba 58 59 59 61 63 66 Height mm 710 710 710 885 1231 1231 idth mm 1694 1973 1973 1794 1766 1766 Depth mm 775 775 775 850 1069 1069 Net eight kg 155 175 175 220 343 343 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 66 67 64 64 66 67 Height mm 1041 1142 1041 1041 1041 1142 idth mm 1083 1083 981 981 1083 1083 Depth mm 1083 1083 981 981 1083 1083 Net eight kg 197 268 170 184 197 268 Pipe Connection- Liquid mm 15.88 15.88 12.70 15.88 15.88 15.88 Pipe Connection- Gas mm 34.92 34.92 25.40 28.58 34.92 34.92 Model Name 3FGY300EXY1 3FGY350EXY1 4FGY400EXY1 3FGY450EXY1 4FGY500EXY1 4FGY600EXY1 RCY100EXY1 x 3 RCY100EXY1 + [RCY125EXY1] x 2 RCY100EXY1 x 4 RCY150EXY1 x 3 RCY125EXY1 x 4 RCY150EXY1 x 4 288000 300000 328000 366000 384000 424000 450000 480000 464000 520000 600000 640000 84410 87920 96130 107270 112540 124270 131890 140680 135990 152400 175850 187570 / 2.72 2.78 2.74 2.82 2.81 2.79 / 2.78 3.22 2.98 3.56 3.36 3.51 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Air Flow CFM 9000 10500 12000 13500 15000 18000 External Static Pressure Pa 200 200 200 250 250 300 Sound Pressure Level dba 66 66 66 68 68 70 Height mm 1231 1486 1486 1486 1486 1918 idth mm 1766 2022 2174 2174 2174 2174 Depth mm 1069 1069 1366 1336 1336 1775 Net eight kg 343 440 513 564 606 991 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Sound Pressure Level dba 64 64 / [66] 64 67 66 67 Height mm 1041 1041 / [1041] 1041 1142 1041 1142 idth mm 981 981 / [1083] 981 1083 1083 1083 Depth mm 981 981 / [1083] 981 1083 1083 1083 Net eight kg 184 184 / [197] 184 268 197 268 Pipe Connection- Liquid mm 15.88 15.88 15.88 15.88 15.88 15.88 Pipe Connection- Gas mm 28.58 28.58 / [34.92] 28.58 34.92 34.92 34.92 Air-Cooled Rooftop Packaged A-Series UAT180/240/280/320/450/560/700/850AMY1 UATC10/12AMY1 35 36

Condenser Evaporator Condenser Evaporator Air-Cooled Rooftop Packaged A Series AL GOLD * * Optional Cabinet & Base Construction Daikin rooftop is equipped with a solid base foundation and compact cabinet. The weatherproofed electro galvanized mild steel casing is coated with an epoxy polyester powder costing for protection against corrosion. Forklift slots and rigging hole is provide for better handling purpose. All Daikin rooftop designs were rigorously rain tested at the factory to ensure the water integrity. Insulation 10mm thickness, fire-resistant Polyethylene is used at every possible condensate panel to prevent all forms of water or moisture penetration. Polyethylene, which is also a type of Closed Cell Foam (CCF) insulation has offered the following advantages: Durable external surface that resists dirt tough and resilient. Higher degree of puncture resistance when compared to fiberglass. Easily cleaned surface (if necessary) to further resist microbial growth. Components Expansion device: Optimized capillary tube is used for better performance. However, thermal expansion valves spec can be specified in any project requirement. Compressor: Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimize vibration. Fan: A dynamically balanced forward curved fan with a field changeable pulley package, in order to match the designed supply air requirements. Fan: IP54 rated condenser fan is being used for UAT700/850/C10/C12AMX1. Safety Features High Pressure and loss of refrigerant protection. Compressor & motor current overload protection. Sensor fault indication. Minimum compressor s running time to ensure oil return. Phase sequencer is used to detect for any wrong phase and phase loss during installation and operation. Flat Top Design Unit s flat top design allows the unit to be stacked up at warehouse or even during transportation, resulting in maximum utilization of warehouse and container space. Stackable Auto-Random Restart henever unit stop due to power failure during operation unit automatically restarts at last setting condition once the power is resumed. However, the compressors will restart randomly if more than one unit is installed and share the same phase of power. Option is provided to cancel this feature. Microprocessor Unit Controls Standard units are equipped with microprocessor controller and every unit is come with a microprocessor operated handset, basic functions of these handset are: - Mode selection. - Temperature Setting. - Timer (delay timer for BRC51B and real time timer for BRC51C). - Error code display. Refrigeration System The UAT-A series are factory charged with HCFC-22 (R-22) refrigerant. Choices Of ired Controller BRC51B63/BRC51B64 (Field installed optional accessories) BRC51C61 UAT180/240/280/320/450/560/700/850AMY1 UATC10/12AMY1 Flat top design High ambient application Microprocessor controlled Partial loading (for 2 compressor system) Easy installation Specification for Rooftop A Series - Cooling only MODEL UAT180AMY1 UAT240AMY12 UAT280AMY12 UAT320AMY12 UAT450AMY1 [1] 59000 80000 100000 116000 150000 17290 23450 29300 34000 44000 EER / 3.08 2.43 2.94 2.94 2.51 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Total Power Input 5610 8100 10500 11560 15600 Control Air Discharge Ducted Ducted Ducted Ducted Ducted Operation Sequential Controller Sequential Controller Sequential Controller Sequential Controller Air Flow CFM 1800 2826 3532 3600 5651 External Static Pressure Pa 100 100 100 100 196 Sound Pressure Level dba 63 65 66 68 70 Unit Dimension Sequential Controller Height mm 1000 1000 1000 1000 1200 idth mm 1100 1300 1300 1300 1990 Depth mm 1530 1530 1530 1530 1670 Net eight kg 295 370 400 425 665 Specification for Rooftop A Series - Cooling only MODEL UAT560AMY1 UAT700AMY1 UAT850AMY1 UATC10AMY1 UATC12AMY1 [1] 200000 250000 300000 329000 404000 58600 73270 87930 96420 118410 EER / 2.58 2.56 2.39 2.42 2.53 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Total Power Input 20700 27560 35960 39870 46800 Control Air Discharge Ducted Ducted Ducted Ducted Ducted Operation Sequential Controller Sequential Controller Sequential Controller Sequential Controller Sequential Controller Air Flow CFM 6710 8000 9600 11000 12500 External Static Pressure Pa 196 294 294 300 300 Sound Pressure Level dba 70 74 74 70 70 Unit Dimension Height mm 1200 1735 1735 1974 1974 idth mm 1990 2250 2250 2252 2252 Depth mm 1670 2800 2800 3180 3180 Net eight kg 765 1200 1350 1510 1600 1) Gross cooling capacity based on 26.7 C DB / 19.4 C B indoor and 35 C DB outdoor. Gross capacity does not include the effect of evaporator fan motor heat. 7 38

ide Operating Range The UAT-C series rooftops are specifically designed for High Ambient Application and capable of operating at an outdoor ambient of up to 54 C. B Temperature(ºC) 54 52 19 14 19.4 23 B Temperature (ºC) High Energy Efficiency In line with the market trend of moving towards high energy efficiency products, the UAT-C series is developed with the target of high EER. Model UAT150CXY1 UAT180CXY1 UAT240CXY1 UAT300CXY1 EER @ 35 C (Btu/) 11.5 11.4 11.1 11.1 Efficiency @ 48 C (k/tr) 1.51 1.55 1.62 1.57 Note: Efficiency at 48 C is in compliance with the Kuwait ME minimum requirement of 1.7k/TR. Light and compact The light and compact design of UAT-C series allows for ease of transportation and installation. Separate Service Panels The unit is designed with separate service panels for easy electrical box servicing. Independent Refrigerant Circuit The unit is designed with two independent refrigerant circuit, where user can control each individual system separately. This also allows the unit to run at part load when less capacity is required. Air Discharge Air Return Air-Cooled Rooftop Packaged C-Series Air Discharge and Air Return The UAT-C series is available in Horizontal Air Discharge only, designed with Air discharge on the top, and return air on the bottom for easy duct design. Components: Expansion Device Thermal Expansion Valves is used for better refrigerant control during high ambient application Compressor High efficiency, low noise, hermitically sealed scroll compressor is used to give a better performance Condenser Motor Condenser motor of IP55 insulation class rating, designed with a dust proof bearing to ensure the reliability of the motor and smooth operation all year round. Evaporator Motor The unit is designed with belt driven evaporator motor, which allows for change of pulley in order to accommodate different static pressure and air flow requirement Filter drier Filter drier is installed as standard in every unit UAT150/180/240/300 CXY1 External 3rd Party Testing The UAT-C series have undergone stringent 3rd Party Testing by internationally recognized certification body, INTERTEK to verify on its designed performance data.

Air-Cooled Rooftop Packaged C Series AL GOLD Standard Features COMFORT FIN TYPE Turbo Mode - Rapid cooling/heating with highest fan speed for immediate comfort AL Bare Aluminium Fin UAT150/180/240/300 CXY1 Quiet Mode - Effective cooling with lower noise level GOLD Anti Corrosion Hydrophilic Gold Fin High Energy Efficiency (Complying to Kuwait ME Energy Efficiency Requirement) Improved Performance at 46 C 3rd Party Testing ide Operating range up to 54 C Light and Compact Design Horizontal Discharge Only IP55 Condenser Motor ith TXV and Filter Drier Microprocessor Controlled Unit, with Sequential Controller or Mechanical Control Dry Mode - Keeping the room dehumidified, while maintaining room temperature Auto Mode - Auto switching between cooling and heating mode depending on room and set temperature Sleep Mode AIR FLO Selectable Fan Speed - Different fan speed is available for comfort selection CONTROLLER ith ireless Remote Controller Belt Driven Evaporator Motor ith ired Remote Controller Variable Pitch Pully Drive Package Automatic Vertical Swing - Automatic movement of air discharge louver for uniform air distribution Specification for Rooftop C Series - Cooling Only MODEL UAT150CXY1 UAT180CXY1 UAT240CXY1 UAT300CXY1 Manual Horizontal Air Flow - Adjustable horizontal discharge grille for desired air flow direction [1] 150000 192300 255000 314300 43960 56360 74740 92120 4 ay Air Discharge EER / 3.36 3.33 3.25 3.25 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Total Power Input 13070 16920 23000 28360 Evaporator Control Air Discharge DUCTED DUCTED DUCTED DUCTED Operation MECHANICAL/ SEQUENTIAL CONTROLLER MECHANICAL/ SEQUENTIAL CONTROLLER MECHANICAL/ SEQUENTIAL CONTROLLER MECHANICAL/ SEQUENTIAL CONTROLLER Air Flow CFM 4600 6500 7900 8700 IAQ ashable Saranet Filter - Removal of airborne dust particles through saranet filter ensures cleaner air supply POER SUPPLY Power from External Static Pressure Pa 125 150 200 250 Sound Pressure Level dba 66 68 68 73 Titanium Apatite Photocatalytic Air-Purifying Filter Power from Condenser Unit Dimension Height mm 1390 1390 1690 1650 idth mm 1965 1965 1965 2410 Depth mm 1630 1630 1905 2030 Bio Antibody Filter Net eight kg 600 650 850 980 1) Gross cooling capacity based on 26.7 C DB / 19.4 C B indoor and 35 C DB outdoor. Gross capacity does not include the effect of evaporator fan motor heat. Ionizer

Controller BRC52A BRC52A61 Heatpump with auto mode BRC52A62 Cooling only 1 2 3 4 5 6 7 8 9 10 11 12 1. Vertical Automatic Air Swing 2. Selectable Mode: Auto Mode, Cooling, Heating, Dry, Fan 3. Turbo Function 4. Quiet Function 5. ON Timer Setting 6. Real Time Clock 7. Transmission Source 8. Glow in the dark ON/OFF Button 9. Fan Speed Selection: Low, Med, High, Auto 10. Temperature Setting: Up & Down 11. Sleep Mode Function 12. OFF Timer Setting BRC51A BRC51A61 Heatpump with auto mode BRC51A62 Cooling only Features: Cool/Heat/Fan/Dry/Auto mode Auto/High/Med/Low fan speed Temperature operate in ºC and ºF Turbo and Quiet Function Sleep function Swing function Real time clock and day display 7-days programmable timer Error indicator Key lock and fan lock features Batteries backup and retain setting during power failure Last state memory (Memory backup setting from main board) Delay Timer (1 or 2 hours) Interaction with ireless Handset (BRC52A61/BRC52A62) BRC51B BRC51B61 Heatpump with 3 fan speed BRC51B62 Cooling only with 3 fan speed BRC51B63 Heatpump with single fan speed BRC51B64 Cooling only with single fan speed BRC51C BRC51C61 Heatpump with auto mode Features: Cool/Heat/Fan/Auto mode Temperature ºF or ºC selectable with LED Display Timer Option Error indication Features: Cool/Heat/Fan/Auto mode Real Time Clock 7-days Timer Key Lock available Energy Saving Mode Error Indication Compressor Running Display Compressor Defrost Cycle Display